A prototype scintillator real‐time beam monitor for ultra‐high dose rate radiotherapy

Background: FLASH Radiotherapy (RT) is an emergent cancer RT modality where an entire therapeutic dose is delivered at more than 1000 times higher dose rate than conventional RT. For clinical trials to be conducted safely, a precise and fast beam monitor that can generate out-of-tolerance beam interrupts is required. This paper describes the overall concept and provides results from a prototype ultra-fast, scintillator-based beam monitor for both proton and electron beam FLASH applications. Purpose: A FLASH Beam Scintillator Monitor (FBSM) is being developed that employs a novel proprietary scintillator material. The FBSM has capabilities that conventional RT detector technologies are unable to simultaneously provide: (1) large area coverage; (2) a low mass profile; (3) a linear response over a broad dynamic range; (4) radiation hardness; (5) real-time analysis to provide an IEC-compliant fast beam-interrupt signal based on true two-dimensional beam imaging, radiation dosimetry and excellent spatial resolution. Methods: The FBSM uses a proprietary low mass, less than 0.5 mm water equivalent, non-hygroscopic, radiation tolerant scintillator material (designated HM: hybrid material) that is viewed by high frame rate CMOS cameras. Folded optics using mirrors enable a thin monitor profile of ∼10 cm. A field programmable gate array (FPGA) data acquisition system generates real-time analysis on a time scale appropriate to the FLASH RT beam modality: 100–1000 Hz for pulsed electrons and 10–20 kHz for quasi-continuous scanning proton pencil beams. An ion beam monitor served as the initial development platform for this work and was tested in low energy heavy-ion beams ( 86 Kr +26 and protons). A prototype FBSM was fabricated and then tested in various radiation beams that included FLASH level dose per pulse electron beams, and a hospital RT clinic with electron beams. Results: Results presented in this report include image quality, response linearity, radiation hardness, spatial resolution, and real-time data processing. Furthermore, the HM scintillator was found to be highly radiation damage resistant. It exhibited a small 0.025%/kGy signal decrease from a 216 kGy cumulative dose resulting from continuous exposure for 15 min at a FLASH compatible dose rate of 237 Gy/s. Measurements of the signal amplitude versus beam fluence demonstrate linear response of the FBSM at FLASH compatible dose rates of >40 Gy/s. Comparison with commercial Gafchromic film indicates that the FBSM produces a high resolution 2D beam image and can reproduce a nearly identical beam profile, including primary beam tails. The spatial resolution was measured at 35–40 µm. Tests of the firmware beta version show successful operation at 20 000 Hz frame rate or 50 µs/frame, where the real-time analysis of the beam parameters is achieved in less than 1 µs. Conclusions: The FBSM is designed to provide real-time beam profile monitoring over a large active area without significantly degrading the beam quality. A prototype device has been staged in particle beams at currents of single particles up to FLASH level dose rates, using both continuous ion beams and pulsed electron beams. Using a novel scintillator, beam profiling has been demonstrated for currents extending from single particles to 10 nA currents. Radiation damage is minimal and even under FLASH conditions would require ≥50 kGy of accumulated exposure in a single spot to result in a 1% decrease in signal output. Beam imaging is comparable to radiochromic films, and provides immediate images without hours of processing. Real-time data processing, taking less than 50 µs (combined data transfer and analysis times), has been implemented in firmware for 20 kHz frame rates for continuous proton beams.

2D beam imaging↗

Argon Milling of Bulk and Post-FIB Specimens for Multi-Length Scale Analyses by EBSD, TEM, and APT under Controlled Environments

Correlative investigations involve structural characterization by transmission electron microscopy (TEM) combined with compositional analysis by atom probe tomography (APT) using the same specimen. A critical component of successful correlative analyses is specimen preparation; probing individual atoms requires a surface and subsurface with minimal defects, beginning with the bulk material through to the prepared specimen for TEM or APT analysis. Our previous work showed that low-energy concentrated ion beam Ar ion milling improves TEM [1] and APT [2,3] specimen quality by removing surface oxides and Ga damage caused by focused ion beam (FIB) preparation. Further enhancement in specimen quality of APT specimens is achieved in the established workflow under controlled environments, as shown in [4]. In this work, we present specimen preparation using Ar ion milling techniques not only for the APT specimen, but also the bulk sample for subsequent multi-length scale analyses by electron backscatter diffraction (EBSD), TEM, and APT under controlled environments. The removal of surface damage and oxidation, which is crucial for probing atomic layer specimens by broad and concentrated Ar ion beam milling techniques under controlled environments, is highlighted.

36 MATERIALS SCIENCE↗

A compact dication source for Ba 2+ tagging and heavy metal ion sensor development

Here, we present a tunable metal ion beam that delivers controllable ion currents in the picoamp range for testing of dry-phase ion sensors. Ion beams are formed by sequential atomic evaporation and single or multiple electron impact ionization, followed by acceleration into a sensing region. Controllability of the ionic charge state is achieved through tuning of electrode potentials that influence the retention time in the ionization region. Barium, lead, and cadmium samples have been used to test the system, with ion currents identified and quantified using a quadrupole mass analyzer. Realization of a clean Ba 2+ ion beam within a bench-top system represents an important technical advance toward the development and characterization of barium tagging systems for neutrinoless double beta decay searches in xenon gas. This system also provides a testbed for investigation of novel ion sensing methodologies for environmental assay applications, with dication beams of Pb 2+ and Cd 2+ also demonstrated for this purpose.

47 OTHER INSTRUMENTATION↗

Simulation study of high-current 7 Li 3+ beam acceleration with laser ion source and RFQ linac using direct plasma injection

Accelerator-based neutron sources (ABNS) utilizing the 7 Li(p,n) 7 Be reaction in inverse kinematics offer strong forward-directed neutron emission, making them attractive for compact and clean neutron source with low background neutrons and unwanted radiation. However, practical use of such systems requires lithium ion beam currents that exceed the capability of conventional ion accelerators by two orders of magnitude. In this study, we numerically designed and evaluated a high-current acceleration system based on a direct plasma injection scheme (DPIS), combining a laser ion source (LIS) and a radio-frequency quadrupole (RFQ) linac. The ion extraction optics and RFQ entrance were optimized using IGUN, OPERA, and GPT, demonstrating that over 1.2 A-class beam current can be injected into the RFQ. The RFQ structure was designed under realistic engineering constraints including surface field strength (Kilpatrick factor) and RF power. GPT simulations showed that a 370 mA 7 Li 3+ beam can be successfully accelerated within a ±10 % energy spread. To validate downstream compatibility, we also designed a simplified medium-energy beam transport (MEBT) section and an interdigital H-type (IH) linac, confirming successful acceleration of a 320 mA beam to the total energy of 14 MeV. These results support the feasibility of the DPIS and RFQ approach as a promising solution for compact neutron sources and other high-intensity ion beam applications.

43 PARTICLE ACCELERATORS↗

Fusion Materials Semiannual Progress Report for the Period Ending December 31, 2020

Three ferritic/martensitic alloys; F82H, Fe8Cr2W and CNA3 were studied for the effect of H and He on swelling. Single ion beam (Fe 2+ ), dual ion beam (Fe 2+ +He 2+ ), and triple ion beam (Fe 2+ +He 2+ +H + ) irradiations were conducted at 500°C to a damage level of 50 dpa and dual and triple beam irradiation experiments were conducted at 450°C to 50 dpa. Cavity distribution and swelling were comparable in dual ion beam and triple ion beam irradiated F82H at 500°C, indicating that the role of hydrogen in swelling in triple beam irradiated F82H appeared to be insignificant compared to the role of helium. Swelling in Fe8Cr2W and CNA3 at 500°C was approximately 3-4X greater than that at 450°C. In F82H, the average cavity size and swelling were minimally larger at 500°C than at 450°C. The significant role of hydrogen in swelling has yet to be confirmed. Future efforts will focus on separate effects experiments to understand the role of hydrogen in cavity swelling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion irradiation and modification: The role of coupled electronic and nuclear energy dissipation and subsequent nonequilibrium processes in materials

Understanding material responses to energy deposition from energetic charged particles is important for defect engineering, ion-beam processing, ion-beam analysis and modification, geologic aging, space exploration, and nuclear applications. As an incident ion penetrates a solid, its energy is transferred to electrons and to atomic nuclei of the solid. Much of this electronic energy deposition is subsequently transferred to the atomic structure via electron–phonon (e–ph) coupling, leading to local inelastic thermal spikes in which energy dissipation is influenced by the local environment. In addition, intense ionization can lead to high densities of localized electronic excitations in wide-bandgap materials and ceramics that can affect defect dynamics and atomic mobility. Specifically, energy exchange between electrons and atomic nuclei, along with localized electronic excitations, can lead to substantial competitive (ionization-induced annealing), additive (both electronic and nuclear energy depositions contributing to damage production), and synergistic (more damage than the sums of separate damage processes) effects. Although nonmonotonic effects of the e–ph coupling strength and athermal processes are demonstrated for pre-existing defects and residual damage during ion–solid interactions, there is limited understanding of when such electronic effects must be considered in atomic-scale models of damage production and evolution in a broad variety of materials. Complex ceramics and chemically disordered solid solution alloys with different constituent elements allow a systematic evaluation of defect dynamics and irradiation performance with increasing complexity. Current knowledge regarding tuning of bonding characteristics and chemical disorder to control atomic-level dynamics is reviewed. Although a lack of fundamental understanding obstructs the advancement of reliable predictions for ion beam material modification, it highlights challenges and opens research opportunities. Insights into the complex electronic and atomic correlations with extreme energy deposition will strengthen our ability to design materials and predict ion-irradiation-induced damage in a radiation environment, and they may pave the way to better control fundamental processes and design new material functionalities for advanced technologies.

36 MATERIALS SCIENCE↗

Achieving a large transverse emittance ratio in the Relativistic Heavy Ion Collider: Beam experiments, analytical estimates, and implications for the Electron-Ion Collider

The Electron-Ion Collider (EIC), to be built at Brookhaven National Laboratory, will collide a polarized high-energy electron beam with polarized proton and light ion beams in the center-of-mass energy range of 20–140 GeV, achieving a maximum peak luminosity of up to 1 × 10 34 cm − 2 s − 1 for the proton and electron collisions. To achieve such a high luminosity, the EIC will employ small, flat beams at the interaction point, which requires a transverse emittance ratio of about 11:1. Since 2017, we have carried out a series of beam experiments to test the feasibility of achieving such a large emittance ratio in the Relativistic Heavy Ion Collider (RHIC). Thanks to the existing stochastic cooling and decoupling feedback system in RHIC, we successfully demonstrated a large transverse emittance ratio of 11:1 with gold ion beams in 2023. In this article, we will present more details and data analysis for these experiments, along with analytical estimates and numerical multiparticle simulations, and provide an outlook for future EIC coupling compensation. Published by the American Physical Society 2025

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Picosecond laser generated plasma as a source of singly charged ions for external injection into an EBIS

The focus of this paper is on practical aspects of ion generation by picosecond lasers as a source of low charge state ions for external injection of ions into an electron beam ion source (EBIS). For a ps-laser, compared to a ns-laser currently used at Relativistic Heavy Ion Collier Electron Beam Ion Source (RHIC EBIS), the influence of heat conductivity in the solid target is almost negligible, which results in a lower target consumption rate and less vacuum pressure rise. By using a laser with high repetition rate, it is possible to produce quasi continuous 1+ ion beams for periods of tens of milliseconds, making it possible to take advantage of the ability of the EBIS to accumulate ions in the “slow” injection capture mode. Producing such an ion pulse train is now feasible since ps-lasers with pulse energy up to 10 mJ and rep-rate up to 10 kHz have recently become commercially available. The advantages of this lower current accumulation scheme include: (1) easier beam transport due to lower space charge of lower beam currents required compared to the present single pulse fast injection scheme, (2) better EBIS pulse to pulse ion output stability since pulse to pulse ion variations of the laser source are averaged over a long train of laser pulses, and (3) the possible addition of an isotope separator in which rare beams could be produced and selected at run time from less expensive (unenriched) targets. We studied the properties of plasmas generated by a ps-laser with 1.27 mJ energy within an 8 ps pulse and a repetition rate up to 400 Hz at Argonne National Laboratory to investigate feasibility and specify parameters for a laser ion source for RHIC EBIS using a “slow” injection mode. Al, Ti, Cu, Nb, and Ta targets were tested with various target translation speeds. Here, we demonstrated that a both “slow” and “fast” injection modes are accessible with a single ion source geometry and single injection line, providing the most attractive option for an ion source for external injection into RHIC EBIS trap based on a ps-laser.

43 PARTICLE ACCELERATORS↗

Fast ion transport by sawtooth instability in the presence of ICRF-NBI synergy in JET plasmas

JET experiments have shown that the three-ion scenarios using waves in the ion cyclotron range of frequencies (ICRF) is an efficient way to build fast ion population through beam ion acceleration by radio frequency (RF) waves. Here, such a heating scheme is applied to plasmas with at least two thermal ion species. Analysis of mixed discharges with complex heating schemes requires a workflow that allows to model thermal and fast ion transport consistently. This paper is dedicated to modelling of a mixed plasma discharge with significant fraction of fast ions and contributes to development of fast ion transport models. For interpretive analysis with the TRANSP code a JET hydrogen-deuterium (HD) plasma discharge with neutral beam injection (NBI) and ICRF heating has been chosen. The task is complicated by NBI-ICRF synergy and plasma magnetohydrodynamic activity, like sawtooth crashes. D beam ions accelerated by RF waves form a high energy tail in fast ion distribution. Significant difference between the neutron rate computed by TRANSP and measured one is observed if the same diffusivity for electrons and ions is assumed. Sensitivity studies show that uncertainties in input plasma parameters and thermal ion transport models are crucial for modelling mixed plasma discharges and increased D transport is required to reach the plasma composition consistent with diagnostic measurements at the plasma edge. Fast ion redistribution by a sawtooth instability is characterised by non-resonant transport due to reconnection of magnetic field lines and resonant transport caused by resonance interaction between the instability and fast ions. With ORBIT simulations it has been shown that resonant interaction strongly affects fast ions of high energies, like beam ions accelerated by RF waves and fusion products. For the considered case, fast ion profiles simulated by ORBIT remain peaked after the sawtooth crashes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reactive Oxygen Ion Beam-Induced Deposition for Concurrent Purification of Platinum Nanostructures

Oxygen-focused ion beam induced deposition (O-FIBID) enables the direct-write fabrication of Pt nanostructures while simultaneously enhancing purity concurrently through reactive oxygen–deposit interactions. By systematically varying the dwell time, accelerating voltage, and precursor pressure, the Pt content and conductivity can be controlled. Under optimum conditions, the Pt content reached 63 at.%. Across the dwell-time range used for resistivity measurements, the Pt content increased from 20 to 33 at.%, while the resistivity decreased from 2.9 × 10 4 μΩ·cm to 1.2 × 10 3 μΩ·cm, which is consistent with enhanced percolation through Pt grains and the lower intrinsic resistivity of the purer Pt deposit. The simulation results support a purification mechanism driven by the beam-induced activation of implanted oxygen balanced against the preferential sputtering of Pt. These results demonstrate O-FIBID as a viable method for the nanoscale direct write of conductive Pt without post-processing, and some deviations from conventional FIBID wisdom are observed. These results serve as a foundation for exploring nascent, reactive focused ion beam-induced deposition processes.

deposit purification↗

Neutron generation using pyroelectric crystals

A method for producing a neutrons includes producing a voltage of negative polarity of at least −100 keV on a surface of a deuterated or tritiated target in response to a temperature change of a pyroelectric crystal of less than about 40° C., the pyroelectric crystal having the deuterated or tritiated target coupled thereto, pulsing a deuterium ion source to produce a deuterium ion beam, accelerating the deuterium ion beam to the deuterated or tritiated target, and directing the ion beam onto the deuterated or tritiated target to make neutrons using at least one element of the following: a voltage of the pyroelectric crystal and a high gradient insulator (HGI) surrounding the pyroelectric crystal. The accelerating of the deuterium ion beam is achieved by using an ion accelerating mechanism comprising a pyroelectric stack accelerator having a first thermal altering mechanism for changing a temperature of the pyroelectric stack accelerator.

Tang, Vincent↗

Progress of the laser ion source upgrade (LION2) for RHIC and NSRL program at Brookhaven National Laboratory

At Brookhaven National Laboratory (BNL), the LION2 ion source is being constructed to replace an existing laser ion ablation ion source (LIS) at the EBIS facility, which provides heavy ion beams of multiple ion species for the operation of NASA Space Radiation Laboratory (NSRL) and Relativistic Heavy Ion Collider (RHIC). The LION1 ion source currently provides singly charged ions of Li, B, C, O, Al, Si, Ca, Ti, Fe, Cu, Zr, Nb, Ag, Tb, Ta, W, Au, Bi, and Th with a rapid-species-change capability. An electron beam ion source, Extended-EBIS captures, confines, and ionizes the ions to high charge state, suitable for injection and acceleration by an RFQ accelerator. Typically, single pulses of the LIS ion species for NSRL are changed sequentially during Galactic Cosmic Ray experiments, while multiple pulses of a given ion beam are provided quasi-simultaneously for RHIC. LION2 will have the same capability of the rapid-species-change with improved beam performance and reliability. LION2 is being constructed in a remote assembly location and is expected to finish in December 2023. The removal of LION1 and installation of LION2 is planned during the December 2023 or summer 2024 shutdown.

43 PARTICLE ACCELERATORS↗

Understanding the limitations and potential of micro tensile testing of tungsten and needs for crystal plasticity modelling

Tungsten is the leading plasma facing material candidate due to its exceptional properties. Understanding the response to neutron irradiation is crucial for the lifetime evaluation of tungsten. The limited space in nuclear reactors and the high levels of radioactivity of the specimens after irradiation are significant barriers to accurately measuring the mechanical properties after neutron irradiation. Testing of micro tensile specimens is one approach to reduce the total amount of irradiated material needed for a set of mechanical testing experiments. However, micro samples are not necessarily measuring the bulk material properties, as size effects produce higher measured mechanical properties than is observed in engineering size counterparts. Determining the minimal sample size for reliable bulk property measurement, combined with modeling efforts, is essential. We conducted room temperature tensile tests on tungsten micro tensile specimens fabricated with focused ion beam, plasma focused ion beam and femto-second laser ablation system to dimension of 2×2×7?µm³, 7×7×18?µm³, and 80×100×233?µm³ (width×thickness×gauge-length), respectively. Elevated tensile testing was performed up to 475°C on 5×5×18?µm³ specimens fabricated with focused ion beam. The smallest specimens exhibited a high degree of ductility and strength, whereas the largest specimens demonstrated behavior akin to bulk tungsten. To investigate the effects introduced by the micro specimen fabrication processes and to obtain the necessary bulk dislocation density for the crystal plasticity model, we employed X-ray diffraction depth profiling. This measurement was performed using different X-ray sources with varying penetration depths. Finally, the potential and limitations of micro mechanical tests for tungsten will be discussed.

36 - MATERIALS SCIENCE↗

The scoping, design, and plasma physics optimization of the Eos neutron source stellarator

On the path to a fusion pilot plant, Thea Energy plans to build Eos, a sub-breakeven, deuterium-deuterium, beam-target fusion, stellarator neutron source facility for producing tritium and other valuable radioisotopes. In this paper, a set of 1D plasma physics models are coupled and used to design the operating point of the facility and predict performance. At this foundational stage of the design, analytic and approximate models are sufficient to capture the leading-order effects, and fast enough to run in the inner loop of an optimizer. Higher-fidelity analyses will follow. Models of 1D profile-dependent neutral beam stopping, ion beam slowing down, beam-target fusion, electron-ion classical heat transfer, energy confinement (ISS04), beam pressure, beam heating of ions and electrons, beam-beam fusion fraction, and neutral beam injection and gyrotron heating electrical efficiencies are included. A numerical optimizer is used to determine the minimum required facility electric power to generate tritium at a given rate. A potentially advantageous regime is described in which modern precisely-quasisymmetric stellarators, new high-temperature superconductors, ITER-derived neutral beam injection, and new high-frequency gyrotrons enable a suitible target plasma with hot electrons, cold ions, peaked density and temperature profiles, and high beam-injected ion density. It appears possible at this time for a facility with a medium-scale and medium-strength stellarator whose required facility electric power is less than 40 MW to produce $2.5\times 10^{17}$ neutrons s -1 for the production of radioisotopes. With the addition of a tritium breeding blanket, such a facility could produce 0.2 grams d -1 or 70 grams yr -1 of tritium.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Synergies between H, He and radiation damage in dual and triple ion irradiation of candidate fusion blanket materials

Three ferritic/martensitic alloys were studied to understand the synergistic effect between single ion beam (Fe 2+ ), dual ion beam (Fe 2+ +He 2+ and Fe 2+ +H + ), and triple ion beam (Fe 2+ +He 2+ +H + ) irradiations on cavity evolution. A commercial alloy, F82H, a castable nanostructured alloy, CNA3, and a high purity model alloy, Fe8Cr2W, were irradiated at 400°C to 600°C to a damage level of 50 dpa at a damage rate of 1 × 10 –3 dpa/s with He and H injection rates of 10 and 40 appm/dpa, respectively. Post-irradiation characterization via bright field transmission electron microscopy and high-angle annular dark-field scanning transmission electron microscopy was performed on all irradiated conditions to characterize the cavity size distribution and determine the effects of H/He injection on cavity microstructure. In all three alloys, hydrogen co-injection with helium resulted in an increased cavity number density and maximum cavity size, producing an increase in swelling over that from helium injection alone. Swelling in F82H appears to peak between 450°C and 500°C. At 600°C, swelling was minimal and cavities of high density and small size were confined to grain boundaries and dislocations while at 400°C, swelling is also low with a nearly homogeneous, high density, distribution of very small cavities throughout. Swelling was least in the commercial alloy F82H due to the high sink strength. The CNA3 alloy underwent dissolution of precipitates that lowered the sink strength and resulted in higher swelling than F82H, but less than the model alloy. Electron energy loss spectroscopy (EELS) elemental mapping revealed hydrogen forming a halo-like structure about the periphery of the cavities and helium residing within the cavities themselves. Finally, this observation suggests that hydrogen reduces the surface energy of helium-filled cavities which results in both increased cavity number density and cavity size in triple beam irradiation over dual beam irradiation.

36 MATERIALS SCIENCE↗

Evaluation method of beam instability in laser ion source using solenoid

In a laser ion source using solenoid field confinement, it is known that an ion beam becomes unstable in the certain range of a magnetic field. Although it is essential to quantify the instability when discussing the unstable region of the beam, it is difficult to evaluate the beam instability by peak current or the amount of charge because an irregular change of temporal profile occurs in addition to the shot-by-shot fluctuation of amplitude. In this study, I propose the most appropriate method to evaluate the beam instability using the difference from an average waveform. The validity of the new method was evaluated by comparing three evaluation methods (variation of maximum value, variation of integral of waveforms, and the proposed evaluation method) with the experimentally obtained waveforms with the stable and unstable regions of a solenoid field. The proposed method was verified to best represent the beam instability by laser-induced plasma.

43 PARTICLE ACCELERATORS↗

Site-specific plan-view (S)TEM sample preparation from thin films using a dual-beam FIB-SEM

To fully evaluate the atomic structure, and associated properties of materials using transmission electron microscopy, examination of samples from three non-collinear orientations is needed. This is particularly challenging for thin films and nanoscale devices built on substrates due to limitations with plan-view sample preparation. In this work, a new method for preparation of high-quality, site-specific, plan-view TEM samples from thin-films grown on substrates, is presented and discussed. Here, it is based on using a dual-beam focused ion beam scanning electron microscope (FIB-SEM) system. To demonstrate the method, the samples were prepared from thin films of perovskite oxide BaSnO 3 grown on a SrTiO 3 substrate and metal oxide IrO 2 on a TiO 2 substrate, ranging from 20–80 nm in thicknesses using molecular beam epitaxy. While the method is optimized for the thin films, it can be extended to other site-specific plan-view samples and devices build on wafers. Aberration-corrected STEM was used to evaluate the quality of the samples and their applicability for atomic-resolution imaging and analysis.

BaSnO3↗

Probing elemental diffusion and radiation tolerance of perovskite solar cells via non-destructive Rutherford backscattering spectrometry

Mixed organic–inorganic halide perovskite-based solar cells have attracted interest in recent years due to their potential for both terrestrial and space applications. Analysis of interfaces is critical to predicting device behavior and optimizing device architectures. Most advanced tools to study buried interfaces are destructive in nature and can induce further degradation. Ion beam techniques, such as Rutherford backscattering spectrometry (RBS), is a useful non-destructive method to probe an elemental depth profile of multilayered perovskite solar cells (PSCs) as well as to study the inter-diffusion of various elemental species across interfaces. Additionally, PSCs are becoming viable candidates for space photovoltaic applications, and it is critical to investigate their radiation-induced degradation. RBS can be simultaneously utilized to analyze the radiation effects induced by He+ beam on the device, given their presence in space orbits. In the present work, a 2 MeV He+ beam was used to probe the evidence of elemental diffusion across PSC interfaces with architecture glass/ITO/SnO2/Cs0.05(MA0.17FA0.83)0.95Pb(I0.83Br0.17)3/spiro-OMeTAD/MoO3/Au. During the analysis, the device active area was exposed to an irradiation equivalent of up to 1.62 × 1015 He+/cm2, and yet, no measurable evidence (with a depth resolution ∼1 nm) of beam-induced ion migration was observed, implying high radiation tolerance of PSCs. On the other hand, aged PSCs exhibited indications of the movement of diverse elemental species, such as Au, Pb, In, Sn, Br, and I, in the active area of the device, which was quantified with the help of RBS.