Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IMPACT LOAD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Development of Prototypical District-Scale Models: Preprint

The U.S. has set the climate goal to achieve net-zero greenhouse gas emissions by 2050. District-scale solutions, which include scale-specific opportunities for energy and emissions savings, can be investigated and implemented to help accelerate decarbonization and progress toward this goal. However, there is currently a lack of district-scale models of buildings and community energy systems that can be used to evaluate potential district-scale technologies and strategies across a range of representative community types. This initial work aims to define and develop prototype district models that can be adapted to support the planning, design, and operation of buildings and energy systems in districts considering the complexity and interactions of diverse building loads, weather impacts, distributed energy resources (e.g., PV, EV, electric and thermal energy storage), electric and thermal grid systems, and pricing signals. An overall workflow for developing these prototype district models is established. Stakeholders and potential users of the prototype district models provided technical feedback. The specifications of the selected high priority districts were defined and documented in a scorecard format. An example prototype district model was implemented with the URBANoptTM platform workflows. A case study was performed to demonstrate the model application.

district↗

Impact of Pretreatment and Aging on the Iodine Capture Performance of Silver-Exchanged Mordenite - 12314

Volatile gas emissions from a nuclear fuel recycle facility in the United States are governed by several key regulations, including 10 CFR 20, 40 CFR 61, and 40 CFR 190. Under 40 CFR 190, the total quantity of iodine that may be released to the environment from the entire fuel cycle is limited to 5 millicuries of I-129 per gigawatt-year of electrical energy produced by the fuel cycle. With a reasonable engineering margin, an iodine decontamination factor (DF) of approximately 1000 will be required for the complete fuel cycle. Off-gas treatment in a fuel reprocessing plant must address several gas streams containing iodine, among a number of volatile radionuclides. Past research and developmental activities identified silver-exchanged mordenite (AgZ) as a very promising sorbent based on its acid resistance, relatively high iodine and methyl iodide capacity, and high achievable DF. Recent studies at ORNL have focused on the impacts of long-term exposure to simulated off-gas streams (aging) and pretreatment on the iodine adsorption performance of hydrogen-reduced silver-exchanged mordenite (Ag{sup 0}Z). Experiments were conducted to determine the effects of long-term exposure to both dry and moist air on the iodine sorption capacity of Ag{sup 0}Z. The data indicates that aging reduces the capacity of Ag{sup 0}Z, which must be accounted for to prevent degradation of DF. Because of its high acid resistance, a AgZ sorbent has been selected specifically for application in treating off-gas streams containing iodine. While extensive tests have been conducted in the United States on a form of this sorbent, the specific material previously tested is no longer commercially available and similar materials are currently being evaluated. As part of this evaluation, tests were conducted to determine the iodine sorption properties of this replacement media and the effects of long-term (up to 6 months) exposure to simulated off-gas streams. The ultimate goal is to develop an understanding of the fundamental phenomena that controls aging for this material and other zeolites that could be considered for use in off-gas treatment in the future. The trends in the study results indicate that the amount of elemental silver observed by XRD increases from 0.3 wt% in vendor-supplied AgZ to approximately 5 wt% by reducing the material with hydrogen. The study also concluded that aging decreases the quantity of elemental silver in the material. After 2 months of aging, the Ag{sup 0} content of an experimental sample was reduced from 5 wt% to about 1.3 wt%. The form into which the elemental silver is converted during aging was not determined. Experimental tests have been initiated to study how aging of Ag{sup 0}Z impacts iodine loading on the zeolite. Loading tests with un-aged Ag{sup 0}Z resulted in an 81% silver utilization. The loading capacity of iodine on Ag{sup 0}Z was reduced with aging in dry air. Material aged for 6 months in dry air had a 40% reduction in iodine loading capacity. Under moist-air aging conditions, a significant decrease in the rate and total loading (∼45% of theoretical) of iodine uptake can be observed beginning with the shortest aging period (i.e., after 1 month) when compared with the loading curve using Ag{sup 0}Z with no aging. Increasing exposure time to the humid air used to age the Ag{sup 0}Z beyond 1 month resulted in a slight additional reduction in capacity to about 35% of theoretical at 2 months. Virtually identical capacity was observed with 4 months of aging. Compared to the non-aged material, the 1 month dry-air aged Ag{sup 0}Z shows about a 35% reduction (approximate) in iodine loading capacity and the 6 month dry-air aged Ag{sup 0}Z shows about a 50% reduction. These studies generated several questions that will be addressed in future tests. They include the following: Is there indeed degradation over time (in storage) in the iodine adsorption performance of Ag{sup 0}Z? Once reduced, how should the Ag{sup 0}Z be stored- under a hydrogen atmosphere, an inert atmosphere, a desiccant, or some other method or combination of methods? Does Ag{sup 0}Z have a 'shelf life' that must be considered after receipt from a vendor and before use in a plant? Also, how should a column of Ag{sup 0}Z be stored offline in a processing plant (parallel column) arrangement? Future tests will also include increasingly challenging aging environments such as acid vapor conditions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of Material Balance Approaches for Hanford Direct-Feed Low Activity Waste Processing - 20022

The Hanford Site has accumulated millions of gallons of tank waste from reprocessing spent fuel to recover plutonium, uranium, cesium, and strontium. The supernatant from the accumulated tank waste will be treated using a Direct Feed Low-Activity Waste approach. The supernatant will be treated to remove solids and cesium in the Tank-Side Cesium Removal process in the Hanford tank farm, then vitrified in a semi-batch process in the Hanford Waste Treatment and Immobilization Plant (WTP). Currently, each batch of feed is sampled at three locations prior to being fed to the melter: the feed qualification tank in the Hanford tank farm as well as the concentrate receipt vessel (CRV) and melter feed preparation vessel (MFPV) in the WTP. The feed qualification sample is taken from a large batch of accumulated feed, only two to three samples are expected each year. Approximately 275 samples from the CRVs and 1100 samples from the MFPV are expected each year. An evaluation was performed to determine if a material balance based on the feed qualification sample could replace most of the sampling in the CRVs and MFPVs. The evaluation consisted of three elements: (1) determination of the practicality of using a material balance to estimate the stream composition of the CRV and MFPV contents, (2) evaluation of whether the material balance could be automated using the existing process control system, and (3) determination of the uncertainty in glass composition using the material balance approach. It is assumed that periodic sampling at the CRV and MFPV would be performed periodically to re-baseline the material balance, evaluations are in progress to determine the frequency of this periodic sampling. Process sample locations downstream of the melter were reviewed as well, but the partitioning of semi-volatile species in the melter was determined to preclude extending the material balance approach past the melter. It was determined that replacement of the CRV sample location was feasible and did not increase process uncertainty or significantly impact waste loading. Replacement of the MFPV sample was also determined to be feasible, but that measurement of the glass former chemical addition may be needed prior to addition of these chemicals to the MFPV. This measurement could be performed by an in situ laser-induced breakdown spectroscopy (LIBS) system. Limited tests were performed to evaluate LIBS for direct measurements of the low-activity waste melter feed. The use of a material balance would eliminate over 1200 samples each year if only 10% of the CRV and MFPV batches are sampled and could likely allow the WTP laboratory to operate on days only versus 24/7 operation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impact of Time-Varying Passenger Loading on Conventional and Electrified Transit Bus Energy Consumption

Transit bus passenger loading changes greatly over the course of a workday. Therefore, time-varying vehicle mass as a result of passenger load becomes an important factor in instantaneous energy consumption. Battery-powered electric transit buses have restricted range and longer 'fueling' time compared with conventional diesel-powered buses; thus, it is vital to know how much energy they require. Our previous work has shown that instantaneous transit bus mass can be obtained by measuring the pressure in the vehicle's airbag suspension system. This report leverages this novel technique to determine the impact of time-varying mass on energy consumption. Sixty-five days of velocity and mass data were collected from in-use transit buses operating on routes in the Twin Cities, MN metropolitan area. The simulation tool Future Automotive Systems Technology Simulator was modified to allow both velocity and mass as time-dependent inputs. This tool was then used to model an electrified and conventional bus on the same routes and determine the energy use of each bus. Results showed that the kinetic intensity varied from 0.27 to 4.69 mi-1 and passenger loading ranged from 2 to 21 passengers. Simulation results showed that energy consumption for both buses increased with increasing vehicle mass. The simulation also indicated that passenger loading has a greater impact on energy consumption for conventional buses than for electric buses owing to the electric bus's ability to recapture energy. This work shows that measuring and analyzing real-time passenger loading is advantageous for determining the energy used by electric and conventional diesel buses.

33 ADVANCED PROPULSION SYSTEMS↗

Sensitivity Analysis of Numerical Modeling Input Parameters on Wind Turbine Loads in Deterministic Transient Load Cases

Aero-hydro-elastic-servo numerical models used to design and analyze wind turbines are based on thousands of variable input parameters that dictate the inflow, aerodynamic, structural, and control characteristics of the system as well as sea state, hydrodynamic, and mooring characteristics for fixed-bottom and floating offshore wind turbines. Each of these parameters has some level of uncertainty, which can significantly impact the predicted loads. Understanding the uncertainty in the inputs is critical to understanding the uncertainty in the outputs. This work demonstrates a screening technique to identify which parameters ultimate loads are most sensitive to so that more focus can be given to quantifying the possible range of those parameters. This technique has been demonstrated previously for different turbine and load case types and is extended here for a floating offshore wind turbine in design load cases with transient events both in the inflow and operations. Each load case features a deterministic gust, including variations in wind speed, direction, and shear. Load cases are considered with an operating turbine as well as with prescribed fault, startup, and shutdown procedures. The study found that key input parameters with a large impact on loads include the length of the gust, the magnitude of direction change and speed in the gust, the initial wind speed, and the shape of the gust profile.

17 WIND ENERGY↗

A Study of the Impact of Peak Demand on Increasing Vulnerability of Cascading Failures to Extreme Contingency Events

The vulnerability of large power systems to cascading failures and major blackouts has become evident since the Northeast blackout in 1965. Based on analyses of the series of cascading blackouts in the past decade, the research community realized the urgent need to develop better methods, tools, and practices for performing cascading-outage analysis and for evaluating mitigations that are easily accessible by utility planning engineers. PNNL has developed the Dynamic Contingency Analysis Tool (DCAT) as an open-platform and publicly available methodology to help develop applications that aim to improve the capabilities of power planning engineers to assess the impact and likelihood of extreme contingencies and potential cascading events across their systems and interconnections. DCAT analysis will help identify potential vulnerabilities and allow study of mitigation solutions to reduce the risk of cascading outages in technically sound and effective ways. Using the DCAT capability, we examined the impacts of various load conditions to identify situations in which the power grid may encounter cascading outages that could lead to potential blackouts. This paper describes the usefulness of the DCAT tool and how it helps to understand potential impacts of load demand on cascading failures on the power system.

indexes↗

Impact assessment and remediation strategies for roadway construction in acid-bearing media: case study from Mid-Appalachia

The likelihood of encountering land impacted by current and/or historic coal mining activities is high when constructing roadways in the Mid-Appalachian region. Through additional disturbance of these lands, environmental impacts such as acid and dissolved metals loading and subsequent impacts to aquatic flora and fauna will ensue. Consequently, it is necessary to affect a paradigm shift in roadway design and construction to account for the presence of factors that compound the already difficult task of working in a region characterized by steep topography and aggressive geochemistry. In this study, assessments of the water chemistry and biological impacts of a waste pile containing spoils from previous mining and the presence of an exposed coal mine bench were made as representative microcosmic examples of typical conditions found in the region. Based on quantitative measurements of water quality and biological conditions, recommendations are presented for the assessment and avoidance of impacts prior to construction through acid-bearing materials and suggestions are offered for postconstruction remediation at previously impacted sites.

01 COAL, LIGNITE, AND PEAT↗

Flexible Residential Test Facility: Impact of Infiltration and Ventilation on Measured Cooling Season Energy and Moisture Levels

Air infiltration and ventilation in residential buildings is a very large part of the heating loads, but empirical data regarding the impact on space cooling has been lacking. Moreover, there has been little data on how building tightness might relate to building interior moisture levels in homes in a hot and humid climate. To address this need, BA-PIRC has conducted research to assess the moisture and cooling load impacts of airtightness and mechanical ventilation in two identical laboratory homes in the hot-humid climate over the cooling season.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Flexible Residential Test Facility: Impact of Infiltration and Ventilation on Measured Cooling Season Energy and Moisture Levels

Air infiltration and ventilation in residential buildings is a very large part of the heating loads, but empirical data regarding the impact on space cooling has been lacking. Moreover, there has been little data on how building tightness might relate to building interior moisture levels in homes in a hot and humid climate. To address this need, BA-PIRC has conducted research to assess the moisture and cooling load impacts of airtightness and mechanical ventilation in two identical laboratory homes in the hot-humid climate over the cooling season.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Water and Climate Impacts on ERCOT Long-Term Systems Assessment

Water and climate change pose many potential challenges to the electric power system. Substantial water is withdrawn every day to support thermoelectric power generating unit operations, and changes to water supply have the potential to affect generation dispatch. Climate change can accelerate growing demand for electricity, which can necessitate additional generating capacity, often in locations with limited water supply. Drought conditions also threaten thermoelectric power plant operations due to streamflow and reservoir levels dropping below intake structures, or water temperatures exceeding a power plants' permitted operating conditions. Here we explore how future climate change might influence decisions related to electricity capacity expansion planning in Electric Reliability Council of Texas (ERCOT) using a multi-model framework. Specifically, water resource modeling is used to simulate climate impacts on the future water supply for thermoelectric and hydropower generation for four future climate projections. Separately, temperature impacts on electricity load are evaluated for these scenarios. These climate impacts are applied to five alternative electricity futures in an electricity capacity expansion model that projects future generation and transmission capacity additions in ERCOT. Results indicate that climate has a measurable influence on future generation and transmission capacity needs, with temperature-driven increases in peak and average load resulting in 5-15 GW additional generating capacity and up to 1 GW additional transmission capacity. Additional capacity is a diverse mix of PV, natural gas, and wind, depending on the makeup of economic, policy and technology assumptions. Climate impacts increase total system costs 2-5%, while the marginal cost of energy and emissions are not affected substantially by climate change effects.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Impact of Open Communication Networks on Load Frequency Control with Plug-In Electric Vehicles by Cyber-Physical Dynamic Co-Simulation

With the increasing electrification of the transportation sector to achieve the carbon neutrality objective, despite the challenges of charging electric vehicles (EV), there are also opportunities through smart charging EVs to improve system frequency stability; however, EV control technologies might require nontraditional communication support. This paper investigates the impacts of communication variations of EV on power system load frequency control through a cyber-physical dynamic system (CPDS) co-simulation. Here, the CPDS is built upon our previously developed transmission-and-distribution dynamic co-simulation model with the added communication variation functions (i.e., delay and packet loss). The case studies consider multiple communication variation scenarios when the system experiences an N-1 generation trip contingency. The scenarios include communication delays and packet loss using both homogeneous and heterogeneous assumptions. The outcomes of this work can help improve EV frequency regulation services and provide robust and effective tests for different load frequency control algorithms of the future power systems.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

Technology Solutions Case Study: Impact of Infiltration and Ventilation on Measured Space Conditioning Energy and Moisture Levels in the Hot-Humid Climate

Air infiltration and ventilation in residential buildings is a very large part of the heating loads, but empirical data regarding the impact on space cooling has been lacking. Moreover, there has been little data on how building tightness might relate to building interior moisture levels in homes in a hot and humid climate. To address this need, BA-PIRC conducted research to assess the moisture and cooling load impacts of airtightness and mechanical ventilation in two identical laboratory homes in the hot-humid climate over the cooling season.

BA-PIRC↗

New features of the ECH control system on DIII-D and impact of power modulation on collector loading

In order to increase the reliability and improve the availability of electron cyclotron heating (ECH) and current drive during a plasma shot, an adaptive gyrotron command generator has been designed and implemented in all gyrotron systems on the DIII-D tokamak. This adaptive real-time generator is able to detect imminent faults, including gyrotron body overcurrent faults that can develop in a few microseconds, block faults, and restart RF generation within 10–30 ms, faster than the DIII-D energy confinement time. The adoption of this adaptive generator has substantially improved the performance of a depressed-collector gyrotron with recurrent body current faults, and has assisted the ECH system to achieve a record reliability of 95% during the last experimental campaign. The impact of power modulation on the collector loading of a depressed-collector gyrotron has been experimentally studied using calorimetry and collector maps taken by a diagnostic developed in-house. While lowering the modulation duty cycle kept the collector power constant as a result of low beam-wave efficiency during the modulation low state, an observed power redistribution inside the collector increased the peak collector power density, which reached levels above the manufacturer power density limit for low duty cycles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Using Synchronization as an Indicator of Controllability in a Fleet of Water Heaters

Peak reduction is an important concern that can help reduce the growing stress on distribution grid and allow to defer investments in new capacity. However, the growing concern for customer privacy and comfort may impact the performance of load control for residential devices. Water heaters represent a convenient way of reducing peak due to their ability to store thermal energy for future use. In this paper, we developed a methodology to help utilities gain more insight with respect to the impact of load control efforts for shaving peak with no necessary information about the water heaters except the device status (on/off). To this end, we use a fleet of water heaters in a controlled residential neighborhood in Atlanta, GA. Our findings show that convergence in device status can serve as a proxy for peak shifting during hours of the evening peak.

demand response↗

Impacts of Experimentally Obtained Harmonic Spectrums of Residential Appliances on Distribution Feeder: Preprint

This paper focuses on the harmonic load flow study for a set of residential loads and the impacts of the harmonic contents on the distribution feeder. Owing to the increased use of the power electronic based appliances and energy efficient home equipment like the lighting loads, the percentage of non-linear loads has increased in the distribution system which can impact the system performance, loss, and stability. Thus a comprehensive knowledge of their power quality and harmonic analysis is essential to improve the load models, voltage stability assessment, determining possible interactions at harmonic frequencies, protection planning, and the effect of the system impedance. For this study, the household appliances include the lighting, power electronics, resistive, and motor loads with a nominal supply voltage of 120 V single-phase or 240 V split-phase at a nominal frequency of 60 Hz. The harmonic spectrum as obtained from the experimental data is used to solve the harmonic load flow for a detailed secondary network including the distribution transformer extracted from a real distribution feeder's model. Additionally, the impact of the voltage harmonic on a three phase test load is presented through experimental results. The harmonic data of the transformer terminal voltage as obtained from the former load flow study is scaled to generate the source voltage for the three phase configuration of the grid simulator to make the test setup very similar to a real scenario.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact behaviour of Napier/polyester composites under different energy levels

The effects of different energy levels on the impact behaviour of Napier fibre/polyester reinforced composites were investigated. Napier fibre was extracted using traditional water retting process to be utilized as reinforcing materials in polyester composite laminates. 25% fibre loading composite laminates were prepared and impacted at three different energy levels; 2.5,5 and 7.5 J using an instrumented drop weight impact testing machine (IMATEK IM10). The outcomes show that peak force and contact time increase with increased impact load. The energy absorption was then calculated from the force displacement curve. The results indicated that the energy absorption decreases with increasing energy levels of the impact. Impacted specimens were observed visually for fragmentation fracture using an optical camera to identify the failure mechanisms. Fracture fragmentation pattern from permanent dent to perforation with radial and circumferential was observed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Impact of Infiltration and Ventilation on Measured Space Conditioning Energy and Moisture Levels in the Hot-Humid Climate, Cocoa, Florida (Fact Sheet)

Air infiltration and ventilation in residential buildings is a very large part of the heating loads, but empirical data regarding the impact on space cooling has been lacking. Moreover, there has been little data on how building tightness might relate to building interior moisture levels in homes in a hot and humid climate. To address this need, BA-PIRC has conducted research to assess the moisture and cooling load impacts of airtightness and mechanical ventilation in two identical laboratory homes in the hot-humid climate over the cooling season.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamic tensile fracture of mortar at ultra-high strain-rates

During the lifetime of a structure, concrete and mortar may be exposed to highly dynamic loadings, such as impact or explosion. The dynamic fracture at high loading rates needs to be well understood to allow an accurate modeling of this kind of event. In this work, a pulsed-power generator has been employed to conduct spalling tests on mortar samples at strain-rates ranging from 2 × 10{sup 4} to 4 × 10{sup 4} s{sup −1}. The ramp loading allowed identifying the strain-rate anytime during the test. A power law has been proposed to fit properly the rate-sensitivity of tensile strength of this cementitious material over a wide range of strain-rate. Moreover, a specimen has been recovered damaged but unbroken. Micro-computed tomography has been employed to study the characteristics of the damage pattern provoked by the dynamic tensile loading.

36 MATERIALS SCIENCE↗