Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “High pressure instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Time-resolved particle image velocimetry

Time-resolved particle image velocimetry (TR-PIV) has become widespread in fluid dynamics. Essentially a velocity field movie, the dynamic content provides temporal as well as spatial information, in contrast to conventional PIV offering only statistical ensembles of flow quantities. From these time series arise further analyses such as accelerometry, space-time correlations, frequency spectra of turbulence including spatial variability, and derivation of pressure fields and forces. The historical development of TR-PIV is chronicled, culminating in an assessment of the current state of technology in high-repetition-rate lasers and high-speed cameras. Commercialization of pulse-burst lasers has expanded TR-PIV into more flows, including the compressible regime, and has achieved MHz rates. Particle response times and peak locking during image interrogation require attention but generally are not impediments to success. Accuracy considerations are discussed, including the risks of noise and aliasing in spectral content. Oversampled TR-PIV measurements allow use of multi-frame image interrogation methods, which improve the precision of the correlation and raise the velocity dynamic range of PIV. In combination with volumetric methods and data assimilation, a full four-dimensional description of a flow is not only achievable but becoming standardized. Lastly, a survey of exemplary applications is followed by a few predictions concerning the future of TR-PIV.

47 OTHER INSTRUMENTATION↗

An experimental, theoretical, and kinetic modeling study of post-flame oxidation of ammonia

The post -flame oxidation rate of ammonia was investigated in a novel atmospheric pressure flow reactor at temperatures of 1280 ± 16 K and as a function of residence time and mixture composition (1-10% O 2 , dry and moist). The experimental results, as well as selected data from literature, were analyzed using an updated detailed chemical kinetic model. The medium temperature, very lean conditions enhance the importance of reactions of the nitroxyl (HNO) intermediate. High-level theory was used to calculate the rate constant for HNO + NH 2 , indicating that this step is significantly faster than values used in literature. Furthermore, a trajectory based approach was used to determine collision efficiencies for selected bath gases for HNO + M. The experimental results show that the NH 3 oxidation rate increases with temperature and O 2 concentration, while the presence of water vapor slightly inhibits reaction. Formation of NO and N 2 O was strongly promoted at higher levels of O 2 . Modeling results agreed well with the measurements, except at the lowest level of O 2 . The predicted oxidation rate of NH 3 was shown to result from a delicate balance between chain branching and terminating steps involving NH 2 , H 2 NO, and HNO. Recent theoretical work on reactions of these species by Klippenstein and coworkers and Stagni et al. was instrumental in improving modeling predictions. After initiation, NO reached a pseudo -steady-state level, where the pathways to NO were largely balanced by the NH 2 + NO reaction. Nitric oxide was partly oxidized to NO 2 , with the NH 2 + NO 2 reaction responsible for most of the N 2 O formation. Novelty and significance statement: This study provides the first detailed kinetic analysis of the lean postflame oxidation of ammonia, based on time -resolved flow reactor data in a novel reactor. In addition to the post -flame oxidation rate of ammonia, data for formation of NO and N 2 O were compared with modeling predictions. The medium temperature, very lean conditions enhance the importance of reactions of the HNO and H 2 NO intermediates. Inclusion in the model of results from recent high-level theoretical work, including present calculations for HNO + NH 2 and HNO + M, was crucial for capturing the observed behavior. It is argued that the post -initiation steady-state NH 3 oxidation rates constitute important data for model validation, along with ignition delays and laminar flame speeds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sizing and Selection of Pressure Relief Valves for High-Pressure Thermal–Hydraulic Systems

This study covers the critical concerns related to the sizing, selection, installation, maintenance, and testing of pressure safety valves (PSVs). The aim is to ensure the safety of pressurized systems, hydrostatic transmission systems, and hydraulic plants, including process plants, thermal power plants, and nuclear reactor systems. PSVs are devices that ensure the safety and reliability of pressurized vessels, lines, and systems during overpressure events. The task of selecting which PSV features are of greatest value for a specific purpose is complex—especially in the design of a high-pressure experimental thermal–hydraulic facility for hydrostatic and transient testing of the reactor system—when the systems are in the design and development phases and require qualification and demonstration to prove that they have reached a given level of technological readiness. The present study highlights the required steps for users to follow the associated rules, guidelines, and recommendations. As a part of this research, case studies are presented to help readers better understand the applicable strategy and standards. A discussion and a review of PSV performance degradation and failure are summarized to provide a better understanding of varied process applications and conditions, including fluid flow dynamics, boundary-layer formation and pressure drops, gas bubble formation and collapse, geometric configurations, inlet/outlet piping, abrupt pressure fluctuations, and acoustic resonance. Moreover, this study discusses the servicing and testing of PSVs in a multiphase pressurized system. Overall, it provides a basic overview of how PSVs ensure the safety of pressurized systems, supported by case studies and industrial practices.

02 PETROLEUM↗

Future Opportunities for LWR Irradiations in US Test Reactors

After several years of relatively low activity in the field of Light Water Reactor (LWR) fuel development, the Department of Energy again began to engage in developing new fuel technologies and irradiation performance data prompted by the Fukushima Daichi nuclear accidents. New competencies for irradiation testing in material test reactors in the United States began to be developed at this time using the Advanced Test Reactor (ATR), High Flux Isotope Reactor (HFIR), Massachusetts Institute of Technology Reactor (MITR), and the Transient Reactor Test Facility (TREAT). Capsules for testing fuel and cladding materials in ATR and HFIR were deployed, a Pressurized Water Reactor (PWR) condition loop for testing fuel rods was established in ATR, cladding corrosion studies were performed using a water loop in MITR, and TREAT pulse testing capabilities were commissioned for fuel rods in water capsules. The more recent and unexpected closure of the Halden Boiling Water Reactor (HBWR) also prompted further investments in Loss of Coolant Accident (LOCA) testing capabilities at TREAT. New configurations of these test devices show further potential in enhanced steam condition control and other investigations are building toward a flowing water loop for testing transient to dryout conditions. The closure of HBWR also prompted a major project currently underway to construct additional water loops in ATR where a novel approach is being pursued to enable Boiling Water Reactor (BWR) conditions. A meaningful collaborative project was awarded to MITR which, amidst an unexpected major overhaul of the reactor, has expanded cladding corrosion test capabilities at MITR. New explorations have led to methods for unique experiments at HFIR including channel box irradiations. New device developments are also bridging toward future potential for instrumented capsule irradiation tests in ATR and HFIR. Finally, a new project referred to as the System Physics Advanced Reactor Critical facility (SPARC) is gaining traction towards a large zero-power reactor able to produce physics validation data for LWR fuel bundle designs with increased enrichment and enhanced absorbers for 24-month operation cycles. This paper provides a brief summary of the status of these irradiation testbed capabilities with an emphasis on current efforts toward future capabilities to obtain new data and maximize the performance potential of LWR fuel technologies.

Woolstenhulme, Nicolas [Idaho National Laboratory ↗

Smart Methane Emission Detection System Development (Final Report)

Working with the Department of Energy's National Energy Technology Laboratory, Southwest Research Institute® (SwRI®) developed a system to identify methane leaks reliably, accurately, and autonomously at critical midstream sections of the natural gas distribution network in real-time for the purpose of mitigating methane emissions using Optical Gas Imaging (OGI) cameras. SwRI's Smart Leak Detection – Methane (SLED/M) adds a high degree of automation to the process of methane leak detection to minimize sources of human error, minimize response time to a leak event, and maximize midstream visibility. Furthermore, SwRI has been working towards integrating Quantitative OGI (QOGI) capabilities into this existing technology. By leveraging Deep Learning, SwRI now has the capability to estimate fugitive emission leak rates quickly and reliably, which allows operators to detect emissions, quantify leak rate, prioritize repairs, and validate the repairs in a single instrument. The next generation QOGI technology leverages the same cameras used in Leak Detection and Repair (LDAR) programs, with improvements in safety and speed for traditional quantification-based repairs, ultimately leading to less overhead cost for the operators. The goals for this research were to develop two types of models with the following goals: Run in real-time on the edge (≥ 12 Hz), Classification: Achieve less than 5% false positive detection, Classification: Achieve ≥ 95% methane plume detection rate, Regression: achieve ≤ 10 standard cubic feet per hour (scfh) prediction > 70% of the time. In order to achieve these results, multiple infrared (IR) and other sensors were investigated in tandem with the midwave IR (MWIR) OGI to provide additional information to train the underlying models. Information on atmospheric conditions including humidity, temperature, pressure, and solar radiation was provided by a weather station. Several machine learning and deep learning architectures and methods, including looking at quantized classification networks and regressions networks, were explored. As further data was collected, curated, and labeled, it allowed for more refined regressive networks to be adequately trained, leading to better insight into the true flow rates being observed. An important valuable deliverable of this research effort was the development of an advanced network which underwent multiple iterations capable of giving a continuous output. The current network has a predicted mean average percentage error (MAPE) of 12.3% just outside our target goal of 10.00%, but an accuracy of 97.78% at ±50 scfh, well within the overall goal for the Department of Energy (DOE) program. Upon closer inspection, it was observed that more than 10% of datapoints contributing to the MAPE predictions were the result of low flow rate predictions and are beyond the sensitivity of instrument measurement as a result of normal operational variation and noise.

03 NATURAL GAS↗

EUSO-SPB2 Fluorescence Telescope trigger test within the EUSO@TurLab Project

The second generation Extreme Universe Space Observatory on a Super-Pressure Balloon (EUSO-SPB2) mission is on track to be approved by NASA for a long duration flight (up to 100 days) in 2023 from Wanaka, New Zealand. EUSO-SPB2 will monitor the night atmosphere of the Southern hemisphere from 33 km altitude to detect Ultra-High Energy Cosmic Rays (UHECRs) and search for astrophysical and cosmogenic neutrinos. EUSO-SPB2 features two telescopes, a Cherenkov (CT) and a Fluorescence (FT) Telescope. The hardware implementation and performance of the FT trigger logic were tested at the TurLab facility, hosted at the University of Turin. In conclusion, the tests proved the correct hardware implementation of the trigger logic and its ability to detect μs timescale transient signals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radon kinetics in a natural indoor radon chamber

An unusual 180 m 3 storage room in the basement of a two-story laboratory building is unventilated, and separated from occupiable rooms by double steel doors. The space completely borders on soil through the concrete floor and two of its concrete walls. The room also contains a separate inner chamber with 1 m thick concrete walls designed to damp vibrations in the room above it. The space boasts a relatively high radon level, 1083 Bq m –3 , which varies with local outdoor environmental conditions. Measurements were made of radon concentrations at various locations and heights within the facility. More than a year of continuous radon concentration data corresponding to a single location are also available, along with measurements of indoor and outdoor pressure, temperature, and humidity. Data were also collected with as many as five fans placed in different locations and cycled on for variable time periods. First order linear kinetic models were created to explain the observed approaches to steady state due to changing conditions and wash-out resulting from intentional ventilation. Results demonstrate a good fit between changes in the radon concentration level and the developed compartmental models. Furthermore, no significant differences were observed between radon concentration at different locations or heights in the chamber.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron density measurement using a partially covered hairpin resonator in an inductively coupled plasma

Hairpin probes are used to determine electron densities via measuring the shift of the resonant frequency of the probe structure when immersed in a plasma. This manuscript presents new developments in hairpin probe hardware and theory that have enabled measurements in a high electron density plasma, up to approximately 10 12 cm -3 , corresponding to a plasma frequency of about 9 GHz. Hardware developments include the use of both quarter-wavelength and three-quarter-wavelength partially covered hairpin probes in a transmission mode together with an easily reproducible implementation of the associated microwave electronics using commercial off-the-shelf components. The three-quarter-wavelength structure is operated at its second harmonic with the purpose of measuring higher electron densities. New theory developments for interpreting the probe measurements include the use of a transmission line model to find an accurate relationship between the resonant frequency of the probe and the electron density, including effects of partially covering the probes with epoxy. Measurements are taken in an inductively coupled plasma sustained in argon at pressures below 50 mTorr. Results are compared with Langmuir probe and interferometry measurements.

47 OTHER INSTRUMENTATION↗

Structure and dynamics of ethane confined in silica nanopores in the presence of CO 2

Fundamental understanding of the subcritical/supercritical behavior of key hydrocarbon species inside nano-porous matrices at elevated pressure and temperature is less developed compared to bulk fluids, but this knowledge is of great importance for chemical and energy engineering industries. This study explores in detail the structure and dynamics of ethane (C 2 H 6 ) fluid confined in silica nanopores, with a focus on the effects of pressure and different ratios of C 2 H 6 and CO 2 at non-ambient temperature. Quasi-elastic neutron scattering (QENS) experiments were carried out for the pure C 2 H 6 , C 2 H 6 :CO 2 = 3:1, and 1:3 mixed fluids confined in 4-nm cylindrical silica pores at three different pressures (30 bars, 65 bars, and 100 bars) at 323 K. Two Lorentzian functions were required to fit the spectra, corresponding to fast and slow translational motions. No localized motions (rotations and vibrations) were detected. Higher pressures resulted in hindrances of the diffusivity of C 2 H 6 molecules in all systems investigated. Pore size was found to be an important factor, i.e., the dynamics of confined C 2 H 6 is more restricted in smaller pores compared to the larger pores used in previous studies. Molecular dynamics simulations were performed to complement the QENS experiment at 65 bars, providing supportive structure information and comparable dynamic information. The simulations indicate that CO 2 molecules are more strongly attracted to the pore surface compared to C 2 H 6 . The C 2 H 6 molecules interacting with or near the pore surface form a dense first layer (L1) close to the pore surface and a second less dense layer (L2) extending into the pore center. Both the experiments and simulations revealed the role that CO 2 molecules play in enhancing C 2 H 6 diffusion (“molecular lubrication”) at high CO 2 :C 2 H 6 ratios. The energy scales of the two dynamic components, fast and slow, quantified by both techniques, are in very good agreement. Herein, the simulations identified the fast component as the main contributor to the dynamics. Molecule motions in the L2 region are mostly responsible for the dynamics (fast and slow) that can be detected by the instrument.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Autonomous sputter synthesis of thin film nitrides with composition controlled by Bayesian optimization of optical plasma emission

Autonomous experimentation has emerged as an efficient approach to accelerate the pace of material discovery. Although instruments for autonomous synthesis have become popular in molecular and polymer science, solution processing of hybrid materials, and nanoparticles, examples of autonomous tools for physical vapor deposition are scarce yet important for the semiconductor industry. Here, we report the design and implementation of an autonomous workflow for sputter deposition of thin films with controlled composition, leveraging a highly automated sputtering reactor custom-controlled by Python, optical emission spectroscopy (OES), and a Bayesian optimization algorithm. We modeled film composition, measured by x-ray fluorescence, as a linear function of plasma emission lines monitored during co-sputtering from elemental Zn and Ti targets in an N 2 and Ar atmosphere. A Bayesian control algorithm, informed by OES, navigates the space of sputtering power to fabricate films with user-defined compositions by minimizing the absolute error between desired and measured optical emission signals. We validated our approach by autonomously fabricating Zn x Ti 1-x N y films that deviate from the targeted cation composition by a relative ±3.5%, even for 15 nm thin films, demonstrating that the proposed approach can reliably synthesize thin films with a specific composition and minimal human interference. Moreover, the proposed method can be extended to more difficult synthesis experiments where plasma intensity lines depend non-linearly on pressure, or the elemental sticking coefficients strongly depend on the substrate temperature.

36 MATERIALS SCIENCE↗

Smart Methane Emission Detection System Development (Final Report)

Working with the Department of Energy’s National Energy Technology Laboratory, Southwest Research Institute® (SwRI®) developed a system to identify methane leaks reliably, accurately, and autonomously at critical midstream sections of the natural gas distribution network in real- time for the purpose of mitigating methane emissions using Optical Gas Imaging (OGI) cameras. SwRI’s Smart Leak Detection – Methane (SLED/M) adds a high degree of automation to the process of methane leak detection to minimize sources of human error, minimize response time to a leak event, and maximize midstream visibility. Furthermore, SwRI has been working towards integrating Quantitative OGI (QOGI) capabilities into this existing technology. By leveraging Deep Learning, SwRI now has the capability to estimate fugitive emission leak rates quickly and reliably, which allows operators to detect emissions, quantify leak rate, prioritize repairs, and validate the repairs in a single instrument. The next generation QOGI technology leverages the same cameras used in Leak Detection and Repair (LDAR) programs, with improvements in safety and speed for traditional quantification-based repairs, ultimately leading to less overhead cost for the operators. The goals for this research were to develop two types of models with the following goals: 1. Run in real-time on the edge (≥ 12 Hz) 2. Classification: Achieve less than 5% false positive detection 3. Classification: Achieve ≥ 95% methane plume detection rate 4. Regression: achieve ≤ 10 standard cubic feet per hour (scfh) prediction > 70% of the time In order to achieve these results, multiple infrared (IR) and other sensors were investigated in tandem with the midwave IR (MWIR) OGI to provide additional information to train the underlying models. Information on atmospheric conditions including humidity, temperature, pressure, and solar radiation was provided by a weather station. Several machine learning and deep learning architectures and methods, including looking at quantized classification networks and regressions networks, were explored. As further data was collected, curated, and labeled, it allowed for more refined regressive networks to be adequately trained, leading to better insight into the true flow rates being observed. An important valuable deliverable of this research effort was the development of an advanced network which underwent multiple iterations capable of giving a continuous output. The current network has a predicted mean average percentage error (MAPE) of 12.3% just outside our target goal of 10.00%, but an accuracy of 97.78% at ±50 scfh, well within the overall goal for the Department of Energy (DOE) program. Upon closer inspection, it was observed that more than 10% of datapoints contributing to the MAPE predictions were the result of low flow rate predictions and are beyond the sensitivity of instrument measurement as a result of normal operational variation and noise.

03 NATURAL GAS↗

Analysis of Microwave Resonant Cavity Transducer Degradation Mechanisms

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with the flat wall of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the resonant frequency, which can be detected with a spectrum analyzer. Because the transducer is intended for immersion in a high temperature corrosive fluid, understanding of material degradation is crucial for estimation of transducer performance lifetime, and development of measurement interpretation algorithms. We conducted a preliminary computational investigation of relevant damage mechanisms of a stainless steel 316 cylindrical resonator in FLiBe salt. The two main damage mechanisms, creep and corrosion, were modeled using multiphysics COMSOL software. Degradation was modeled for a temperature range 500°C to 700°C. Coupling of the damage mechanisms was not considered. These models predict significant inelastic deformation at most temperatures due to creep, and qualitatively predict chromium depletion both along the liquid/solid interface and along the grain boundaries. An algorithmic approach for compensation of these degradation effects during fluid flow measurements will be developed in the future work.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Laser-driven ionization mechanisms of aluminum for single particle aerosol mass spectrometry

Single particle aerosol mass spectrometry (SPAMS), an analytical technique for measuring the size and composition of individual micron-scale particles, is capable of analyzing atmospheric pollutants and bioaerosols much more efficiently and with more detail than conventional methods which require the collection of particles onto filters for analysis in the laboratory. Despite SPAMS’ demonstrated capabilities, the primary mechanisms of ionization are not fully understood, which creates challenges in optimizing and interpreting SPAMS signals. In this paper, we present a well-stirred reactor model for the reactions involved with the laser-induced vaporization and ionization of an individual particle. The SPAMS conditions modeled in this paper include a 248 nm laser which is pulsed for 8 ns to vaporize and ionize each particle in vacuum. The ionization of 1 μm, spherical Al particles was studied by approximating them with a 0-dimensional plasma chemistry model. The primary mechanism of absorption of the 248 nm photons was pressure-broadened direct photoexcitation to Al(y 2 D). Atoms in this highly excited state then undergo superelastic collisions with electrons, heating the electrons and populating the lower energy excited states. We found that the primary ionization mechanism is electron impact ionization of various excited state Al atoms, especially Al(y 2 D). Because the gas expands rapidly into vacuum, its temperature decreases rapidly. The rate of three-body recombination (e - + e - + Al + → Al + e - ) increases at low temperature, and most of the electrons and ions produced recombine within several μs of the laser pulse. The importance of the direct photoexcitation indicates that the relative peak heights of different elements in SPAMS mass spectra may be sensitive to the available photoexcitation transitions. We also discuss the effects of laser intensity, particle diameter, and expansion dynamics.

47 OTHER INSTRUMENTATION↗

The EGS Collab Project: Learnings from Experiment 1

The primary objective of the EGS Collab Project sponsored by DOE is to increase the understanding needed to efficiently implement enhanced geothermal systems (EGS). One goal of the EGS Collab project is to create a collaborative research environment in which to study stimulation of crystalline rock at the 10 meter scale. Key to this effort is the collection of high quality data to allow comparison to numerical coupled process models in an effort to build confidence in the codes and modeling techniques used. In response to this, the EGS Collab team has created an underground test bed at the Sanford Underground Research Facility (SURF) in Lead SD at a depth of approximately 1.5 km to examine hydraulic fracturing (Experiment 1). We are currently designing a second test bed aimed at investigating shear stimulation (Experiment 2). At the Experiment 1 location, we have characterized our host rock using laboratory testing and numerous field-based geophysical and geological techniques, and created a well-instrumented test bed to allow us to carefully monitor stimulation events and flow tests. In addition to the installed geophysical sensors, we have used tracer tests, differences in the ambient microbial communities at flow collection locations, and cold water injection to inform us about dynamic flow pathways. In Experiment 1, we have hydraulically stimulated the host rock in a number times at several locations in one well, creating new fractures that connect to existing fractures between the injection and production boreholes. We have performed long-term ambient and chilled water injection tests as an analog to EGS, and have monitored system changes resulting from these water injections through geophysical monitoring, flow and pressure measurements, tracer tests, and microbiology. Here, we summarize the tests performed, issues identified including poroelastic and thermoelastic effects, Joule-Thomson effects, restarting effects, indications of flow channeling, and the primary learnings from Experiment 1.

Enhanced Geothermal Systems, EGS Collab, stimulati↗

Initial in-orbit operation of the soft X-ray spectrometer Resolve onboard the X-ray imaging and spectroscopy mission satellite

The X-Ray Imaging and Spectroscopy Mission satellite was launched on September 6, 2023 (UT). Its Resolve instrument is a high-resolution X-ray spectrometer enabled by a microcalorimeter array thermally anchored to a 50-mK heat sink. Many sensitive, critical sub-systems comprise Resolve, including a multistage cryogenic cooling system, thin-film aperture filters, low-noise electronics, on-board signal processing, and several sources of X-rays for calibration. We summarize the initial on-orbit power-on and checkout of Resolve that commenced immediately after launch. Soon after launch, the cryocoolers were activated, and their operation was successfully established. On October 9, 2023, the first cycle of the adiabatic demagnetization refrigerator was carried out, bringing the sensors to their steady-state operational temperatures. Following this, the energy resolution at 5.9 keV was successfully measured. The energy scale of the system is highly sensitive to the thermal environment surrounding both the sensors and their analog electronics. Gain correction was performed using reference X-ray lines from onboard calibration sources. To optimize cooler frequency settings, noise spectra were collected across a range of frequencies, and the most suitable frequency pair was selected based on the in-orbit environment. During the final phase of the checkout, an attempt was made to open the gate valve, which is designed to protect the Dewar’s interior from external pressure during ground operations and launch. Unfortunately, this attempt was unsuccessful. As a result, the checkout process was temporarily paused, and a stable operational strategy was subsequently developed to enable Resolve to function effectively with the gate valve remaining closed.

X-ray micro-calorimeter↗

Characterization of Precipitation-Induced Radon Progeny Deposition Events Using a City-Scale Sensor Network

Networks of radiation detectors provide a platform for real-time radioactive source detection and identification in urban environments. Detection algorithms in these systems must adapt to naturally-occurring changes in background, which requires well-characterized relationships between precipitation events and their corresponding radiological signature. Here, we present a quantitative and qualitative description of rain-induced radon progeny deposition events occurring in Chicago from September 2023 to February 2024. We measure ambient gamma radiation levels, precipitation rate, temperature, pressure, and relative humidity in a network of sensor nodes. For each identified precipitation period, we decompose spectra into static- and radon-associated components as defined by a non-negative matrix factorization (NMF) algorithm. We find a consistent power-law relationship between a precipitation-dependent peak of the radon progeny proxy (RPP) and the peak strength of the radon-associated NMF component for most precipitation events. We conduct a case study of a rainfall period with abnormally high levels of implied radon progeny concentration and describe its temporal and spatial evolution. We hypothesize that this phenomenon is due to the air mass path that intersects a uranium-rich region of Wyoming. Finally, we cluster precipitation events into three distinct categories. One category roughly corresponds to events with deep low-pressure systems and high relative radon concentration, while another is characteristic of light stratiform rain with slightly higher temperatures and intermediate relative radon concentration. The third category appears to contain weak-gradient or lake breeze convection showers with intermittent precipitation and low relative radon concentration. These findings suggest that radiological anomaly detection could be improved by training unique background models corresponding to each category of meteorological event.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel data analysis method for obtaining better performance from a complex 3D-printed collimator

Additively manufactured scattered beam collimators are increasingly being employed to boost the sample to cell peak signal ratio in high pressure neutron diffraction studies because of manufacturing versatility and performance improvements. We study how the measured diffraction pattern is affected by the presence of a collimator downstream of the sample, and develop a novel protocol that provides more effective background rejection. This protocol takes into account critical performance-determinants that were identified in this study, namely: (i) effectively identifying the collimator pattern on the detector; (ii) understanding the dependence of this pattern on sample and cell composition; and (iii) accurately identifying and differentiating the different regions of the pattern on the detector based on the dependency of the cell or sample and finally (iv) resolving the intensities at regions of the detector where neutrons scattered from the sample are preferentially represented, in order to boost the sample to cell peak signal ratio. Application of this novel analysis protocol is shown to increase the collimator performance over the traditional method.

3D printing↗

Nonlinear magnetohydrodynamic modeling of ideal ballooning modes in high- β Wendelstein 7-X plasmas

We present nonlinear magnetohydrodynamic (MHD) simulations of high- β Wendelstein 7-X plasmas using the stellarator extension of the M3D- C 1 code, building on the recent work that shows benign saturation of ideal ballooning modes above the designed β limit in the standard configuration [Zhou et al., Phys. Rev. Lett. 133, 135102 (2024)]. First, we examine the results' sensitivity to the parallel thermal conductivity. It is found that while an increased parallel conductivity reduces the linear growth rate, the saturated pressure profile is barely affected. Second, we consider the dependence on the profile shape. It is shown that an equilibrium with a peaked pressure profile and lower β is subject to more significant change than a broad profile with higher β and a larger growth rate, suggesting that benign saturation, or nonlinear stability, is not guaranteed and not dictated by linear growth. Third, we study the influence of the magnetic configuration, with the equilibrium rotational transform varied by adjusting the planar coil current. With similar growth rates, similar magnitudes of profile change are found regardless of the presence of a low-order resonance, which implies that the saturation mechanism is not specific to a resonant or non-resonant mode. These results indicate that MHD stability should still be treated seriously in stellarator operation and design, for which nonlinear modeling using tools like M3D- C 1 can play an instrumental role.

Zhou, Yao [Shanghai Jiao Tong University (China)] ↗