Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Hanford Site”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Reconstructing Hanford worker external doses from photons for epidemiology

The accurate reconstruction of external photon doses is essential for credible radiation epidemiology. This article presents the methodology used to derive dose estimates for 37 012 Hanford Site workers included in the Million Person Study. The approach employs historical dose records from the Hanford Radiation Exposure database and a previous epidemiology study. Bias correction factors specific to dosimeter type and period of use were applied and missing annual doses were estimated using a hierarchical nearby method to estimate deep dose equivalent for each worker. For early years with limited detection sensitivity, missed doses were quantified based on expected time-period-specific, low-dose statistical distributions. The revised dose estimates resulted in lower median and mean career doses than unadjusted data, while increasing the number of person-years with nonzero dose. Sensitivity analyses assessed the influence of bias in dosimetry measurements, missed doses and gap years on dose estimates. Differences in cumulative dose estimates between unadjusted and revised annual estimates are most prominent in the early operational years due to the highest bias during that time period.

dose reconstruction↗

Hanford Supplemental Low Activity Waste Simulant Evaporation Testing for Removal of Organics

The Hanford site has approximately 56 million gallons of radioactive waste stored in 177 underground storage tanks. The Hanford Waste Treatment and Immobilization Plant (WTP) is being built to treat and immobilize the tank waste. The baseline method for immobilization of Low Activity Waste (LAW) is vitrification, but additional immobilization capacity is likely needed to supplement the initial melters. An alternative cementitious waste form is being investigated for that future supplemental immobilization method. However, one impediment to a cementitious waste form is the presence of Land Disposal Restricted (LDR) organic chemicals in tank waste. Developing a method to remove the organics would eliminate that impediment to permit possible use of a cementitious waste form. Savannah River National Laboratory (SRNL) performed testing to examine evaporation as a method to remove some prevalent organics from the Supplemental LAW (SLAW) stream. Samples of product streams from the evaporation were analyzed to determine partitioning of the organics. Modeling was also performed to determine if the experimental and modeling results matched. A description of the experimental details, equipment, and results of that testing are included in this report.The work is intended to inform future SLAW flowsheet development activities and gather useful data about the partitioning of constituents through a possible SLAW feed evaporator.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessment of Cold Spraying Mild-Steel Powder onto Mild-Steel Substrate for Development of Waste Tank Repair System - 20515

Infrastructure for nuclear waste storage and processing (e.g., waste tanks, transfer pipelines, evaporators) at the U.S. Department of Energy (DOE) Hanford Site has been in service well beyond its original design life. Past corrosion control methods at Hanford for waste tanks have not been fully successful, as evidenced by leaks forming in tank AY-102, the first double-shell tank (DST) constructed, and significant degradation detected in the primary tanks of AP-102 and AY-101. Failure of infrastructure components can pose a significant risk to the environment, worker safety, and project schedules. Therefore, remotely deployable methods for repairing and extending the service life of the existing tank waste infrastructure are needed. Cold spray has been identified as a potential technique for performing in situ repairs and material buildup for life extension of waste storage and processing infrastructure. Cold-spray repair methods and technology are well-established and are used extensively by industry and the military for making repairs using dissimilar materials. Pacific Northwest National Laboratory is evaluating the process of making repairs using mild-steel powder applied to a mild-steel substrate to minimize the galvanic corrosion potential. This paper presents the initial results for a feasibility ('go/no-go') assessment as to whether low-density deposits with sound metallurgic bonds, to build-back steel plate material, can be achieved using existing commercial cold-spray equipment. An assessment of steel-on-steel deposit is necessary to determine if cold spray is a viable candidate for DST carbon steel plate restoration/repair and thus DST service life extension. Powder properties and preparation requirements have been investigated and operating conditions and parameters for depositing a cold-spray buildup of mild steel on a mild-steel substrate have been determined. Soundness of metallurgic bonding as a function of the operating parameters exercised and results from applying cold spray to lay a deposit over simulated small-diameter flaws in 1/2-inch mild-steel plate are presented. Application of in situ cold-spray repair to the DOE complex has the potential to reduce cost and schedule impacts associated with component failures and the need to procure and construct replacement infrastructure. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impact of gel concentration on filter fluxes in microfiltration of Hanford tank wastes and simulants

Abstract Treatment processes have been proposed that will utilize crossflow filtration to concentrate sludge waste streams at the Department of Energy's Hanford Site. Challenges associated with solid–liquid separation of the waste streams drive a necessary evaluation of available Hanford high level waste (HLW) filtration data. Limiting flux conditions during crossflow filtration are elucidated with the formation of a cake layer on the membrane surface. A mass transfer coefficient between the gel and bulk concentrations plays a critical role in determining filter flux. A correlation between the gel concentration and mass transfer coefficient is made to assist in determining filter performance of select HLW streams. As a process alternative to crossflow filtration, gravity settling of waste streams may be deployed as a solid–liquid separation technique. However, this results in a contrasting performance with the centrifuged solids concentration. A method was developed to estimate expected filtration and settling performance based on physical characterization data for Hanford tank waste samples. By assessing the estimated processing performance of HLW, technical support can be provided during flowsheet planning.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Organic Evaporation and Oxidation Testing in Support of Hanford Sample-and-Send

The Hanford site has approximately 56 million gallons of radioactive mixed waste stored in 177 underground storage tanks. The Hanford Waste Treatment and Immobilization Plant (WTP) is being built to treat and immobilize the tank waste. The baseline method for immobilization of Low Activity Waste (LAW) through the WTP is vitrification, but additional immobilization capacity is needed to supplement the initial LAW melters. An alternative cementitious waste form is being investigated for that future immobilization method to supplement vitrification. However, one impediment to a cementitious waste form is the presence of Land Disposal Restricted (LDR) organic chemicals in tank waste. This work evaluates potential avenues to eliminate that impediment to permit possible use of a cementitious waste form and work towards a decision whether additional LDR organic pretreatment would be required. Savannah River National Laboratory (SRNL) performed testing using simulants to examine evaporation as a method to remove some prevalent organics from LAW. Spiking the caustic LAW simulant with selected regulated organic chemicals found one that clearly decomposes because of caustic instability. Oxidation testing of other organic chemicals found some LDR organics degrade as desired and others are stable in the presence of peroxide and permanganate. In addition to studies with simulants, a literature review was performed to evaluate radiological stability of LDR organics. Descriptions of the experimental details, equipment, and results are included in this report. Evaporation testing consisted of preparing the LAW simulant, spiking that simulant with organic chemicals, and evaporating the mixture via differential distillation. The apparatus was a laboratory-scale vacuum evaporator operated at 60 ±5 torr absolute (vacuum evaporation) and also at atmospheric pressure. The LAW simulant represented the liquid expected to be retrieved from the Hanford tank farms at approximately 4.0 M [Na + ] total sodium ion concentration. The concentration of the organic chemicals added was significantly higher than typically found in the tank waste samples since the higher levels were necessary to assist in analytical measurement and tracking of the spiked species. Organic chemicals were chosen for the work with a consideration of how their volatility compares with that of methanol. This was done by comparing the ratio of the pure water Henry’s law coefficient (K h ) of methanol to that of the compound in question (hereafter termed the K h ratio), where ratios above unity indicated less volatility than methanol. Methanol was chosen because it is a common regulated chemical with relatively low volatility but which has been removed by evaporation in previous laboratory work. While organic separation results depend on evaporator design, laboratory experiments verified that organic partitioning to the overhead condensate stream by evaporation is a practical process. The work reported here found difficulties in quantitative analysis of the organic chemicals in aqueous samples. Most of the time there was insufficient analysis to close a mass balance for evaporator runs, but qualitative evidence of carryover was obtained. The methods were also able to show whether organic chemicals were susceptible or resistant to solution oxidation in permanganate or hydrogen peroxide tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An Online Prototype Toolset for Predicting and Optimizing P&T Performance (FY23 Status Report)

A new web-based toolset is being developed to support ongoing remediation optimization efforts and implementation of an adaptive site management strategy for the 200 West Area Pump-and-Treat (P&T) system at the Hanford Site. This toolset, comprising the well performance index tool and the well optimization pre-screening tool, will offer a user-friendly interface to predict and optimize the P&T well network’s performance at a preliminary level. Efforts in fiscal year (FY) 2023 focused on three main components: updating the existing deep learning model for predicting P&T performance, designing and developing a prototype of a web-based performance index tool, and initiating the conceptual design of the well optimization pre-screening tool. The well performance index tool is based on a pre-trained deep learning model that allows users to select a target contaminant and well screen length, then visualize the predicted performance of potential new wells across the site. The well optimization pre-screening tool includes two separate modules: the pre-computed scenario viewer, which organizes and visualizes offline optimization simulation results, and the quick analysis module, which provides real-time model prediction using user-specified well locations. In FY24, the plan is to add web-based applications to SOCRATES for both the well performance prediction tool and the optimization prescreening tool, with accompanying user and theory guides. These tools are intended to enable an accessible, easily applied, and transparent approach to remedy planning and decision-making.

97 MATHEMATICS AND COMPUTING↗

PART II - Site Assessment and Characterization

This part of the book, includes site assessment and characterization case studies from remediating different areas and historical processes and operations across the Hanford Site

environmental remediation↗

Organic Evaporation, Oxidation, and Hydrolysis Testing in Support of Hanford Sample-and-Send

The Hanford site has approximately 56 million gallons of radioactive mixed waste stored in 156 unretrieved underground storage tanks. The Hanford Waste Treatment and Immobilization Plant (WTP) is being built to treat and immobilize the tank waste. The baseline method for immobilization of Low Activity Waste (LAW) through the WTP is vitrification, but additional immobilization capacity is needed to supplement the initial LAW melters. An alternative cementitious waste form is being investigated for that future immobilization method. However, one impediment to a cementitious waste form is the presence of Land Disposal Restricted (LDR) organic chemicals in tank waste, which are regulated on a concentration-based standard in the final waste form. Hence, if the quantity of organics in LAW is high enough, they must be destroyed or removed to make a waste form compatible with disposal in a mixed low level waste landfill. This work evaluates potential avenues for treatment of LDR organics to eliminate the impediment and permit possible use of a cementitious waste form.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Alternative reductants for foam control during vitrification of high-iron High Level Waste (HLW) feeds

Foaming during vitrification of radioactive waste in Joule-Heated Ceramic Melters (JHCM) is exacerbated by trapping of evolving gases, such as CO 2 , NO x and O 2 , beneath a viscous reaction layer. Foaming restricts heat transfer during melting. Sucrose is employed as the baseline additive at the Hanford site in Washington State, USA to reduce foaming. Alternative carbon-based reductant additives were explored in simulated, inactive Hanford high-iron HLW-NG-Fe2 feeds, for both their effect on foaming and to give insight to the behaviour of multivalent species in glass melts under different redox conditions. Graphite, coke (93% C), formic acid and HEDTA additives were compared with sucrose, and a feed with no additive. Graphite and coke additions proved most effective in reducing the maximum foam volume by 51 ± 3% and 54 ± 2%, respectively, compared with 24 ± 5% for sucrose. Lower foaming could result in more efficient vitrification in JHCMs. Reductants also affected redox ratios in the multivalent species present in the feed. The order of reduction, Mn 3+ /Mn 2+ > Cr 6+ /Cr 3+ > Ce 3+ /Ce 4+ > Fe 3+ /Fe 2+ was as predicted on the basis of their redox potentials. There is less reduction overall, particularly in the Fe 3+ → Fe 2+ , than predicted by the calculations, attributed to the oxygenated atmosphere of the experiments.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of Dose- and Risk-Based Groundwater Cleanup Levels for Low Energy Beta Radioisotopes

Low-energy beta-emitting radionuclides that were released historically during reactor operations and plutonium separations activities at some U.S. Department of Energy sites have migrated into the groundwater, forming contaminant plumes that are subject to federally regulated remediation actions. At the Hanford Site, the low-energy beta-emitting radionuclides include iodine-129, technetium-99, chlorine-36, carbon-14, and tritium (H-3). All are highly mobile in the subsurface, and except for tritium, and have very long half-lives—thousands to millions of years. The geochemistry and transport behavior of these contaminants in the subsurface present significant challenges for remediation of groundwater to federal drinking water standards (DWS)—the appropriate or relevant and applicable requirements (ARARs) for cleanup. For some of the low-energy beta-emitter contaminants, particularly iodine-129, cleanup and restoration of groundwater to DWS may not be attainable within a reasonable timeframe using currently available treatment technologies.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Whose Gas is it anyway? Differentiating the Source of a Large Soil Vapor Plume beneath Two Adjacent Waste Sites - 20487

DOE contractor CH2M Hill Plateau Remediation Company is currently responsible for conducting groundwater contamination monitoring at several RCRA treatment, storage, and disposal units located on the Hanford Site in Richland, Washington State. The Nonradioactive Dangerous Waste Landfill treatment, storage, and disposal unit presents a distinct groundwater monitoring problem because of a large multi-contaminant soil vapor plume beneath it that is a likely source of low-level volatile organic compound groundwater contamination. Adjacent to Nonradioactive Dangerous Waste Landfill is the Solid Waste Landfill. Volatile organic compounds are inventory components of both the Nonradioactive Dangerous Waste Landfill and the Solid Waste Landfill. Therefore, it is possible that both sites could be contributing to the soil vapor plume. For regulatory purposes, it is important to differentiate which site is the primary contributor of volatile organic compounds to the plume. An approach was developed to identify the primary volatile organic compound source of the soil vapor plume beneath Nonradioactive Dangerous Waste Landfill and Solid Waste Landfill. The site conceptual model hypothesis of vapor-phase volatile organic compound transport to the dissolved phase in groundwater was tested by a simple mathematical model of vapor/liquid equilibrium concentrations at the groundwater/air interface. Once it was shown that vapor-phase volatile organic compound transport to groundwater was a valid conceptual model for Nonradioactive Dangerous Waste Landfill and Solid Waste Landfill, spatial and statistical methods were used to determine the primary site contributing to the majority of volatile organic compounds to the soil vapor plume. Average groundwater chloroform, tetrachloroethene, and trichloroethene concentrations from Nonradioactive Dangerous Waste Landfill and Solid Waste Landfill monitoring network wells were plotted on maps of the facilities and immediate vicinities and compared to soil vapor sampling probe locations. Principal component analysis and mixing ratios were used to identify source contributions of each treatment, storage, and disposal unit to the plume. Results of the vapor/liquid equilibrium concentrations mathematical model showed that transport phenomena outweigh steady-state equilibria. Estimated vapor/liquid equilibrium concentrations were considerably lower than soil vapor measurements. The results indicate that dynamic vadose zone and groundwater factors such as decreased vapor concentrations with depth, vapor dilution from dispersion in the vadose zone, and advective and diffusional volatile organic compound dilution in groundwater result in groundwater volatile organic compound concentrations much less than would be measured under steady-state equilibrium conditions. Site source contribution differentiation by principal component analysis and mixing ratios was inconclusive using actual soil gas data because of the similarity in concentration values in both datasets for Nonradioactive Dangerous Waste Landfill and Solid Waste Landfill. Similar data populations suggest mixing of the vapor contributions from both sites by dispersion through the soil matrix pore spaces. However, when groundwater volatile organic compound data were compared between the Nonradioactive Dangerous Waste Landfill and Solid Waste Landfill monitoring networks, Solid Waste Landfill mean concentrations were higher, suggesting more vapor-phase volatile organic compound transport to groundwater at those locations. Simulated volatile organic compound soil vapor and groundwater datasets created to test the methods developed for this study show that the method can be successful in source differentiation when significantly different datasets are compared. This paper will describe a method of testing a conceptual model for vapor-phase contaminant transport to groundwater and for differentiating site sources of contaminants comprising a mixed-constituent soil vapor plume. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effect of Na Concentration on Cs Distribution with Crystalline Silicotitanate in Tank Waste Simulants

Crystalline silicotitanate (CST) ion exchange media is currently utilized in the tank side cesium removal (TSCR) system on the Hanford site to remove Cs-137 from the tank waste supernate. As the main dose contributor to the liquid supernate in Hanford tank waste, it is necessary to remove the Cs-137 to expedite low activity waste processing and immobilization. Ongoing batch contact experiments with CST have been done to tease out the impact of group II metals, anions, potassium, and temperature on Cs removal to better understand bounding conditions for operations as well as aid in development of a wholesome isotherm model to predict Cs behavior in the tank waste. This paper discusses the impact of Na concentration on Cs exchange and provides insight into the challenges associated with activity coefficient estimations for modeling Cs distribution in tank waste matrices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impact of dilution-induced precipitates on the filtration of Hanford liquid tank wastes

To facilitate its vitrification, a portion of the radioactive wastes currently stored at the Hanford Site will be staged and treated using tank-side operations to render their chemistry compliant with the requirements of Hanford’s low-activity waste vitrification facility. Initial sampling of staged feeds indicates that process-water dilution, used to reduce waste feed sodium content to levels acceptable for vitrification (5–6 M Na), may cause precipitation of fine, difficult to settle solids that could affect downstream tank-side filtration and ion-exchange. However, dilution-induced precipitation has not been demonstrated under controlled, rigorous laboratory conditions. This paper presents a set of qualitative and quantitative assessments of dilution-induced precipitation using a nonradioactive, Hanford Tank AP-105 simulated waste. Further, these studies found that dilution of AP-farm waste simulants induced precipitation of up to 150 ppm solids, regardless of whether dilution was done with process water (which contains, among other analytes, naturally occurring Ca and Mg) or deionized water. Naturally occurring process-water analytes appeared to accelerate the rate (and possibly extent) of precipitation. Filtration of diluted waste simulants also found that the precipitated solids challenged prototypic tank-side filter operations; however, the impact to filtration performance was readily managed through waste staging settle/decant operations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

PNNL Measurement Results for the 2018 FlatTop Criticality Nuclear Accident Dosimetry Exercise at the Nevada National Security Site (IER-253)

The Pacific Northwest National Laboratory (PNNL) participated in the FlatTop exercise IER-253 at the National Nuclear Security Site (NNSS) during the week of May 21, 2018. This report summarizes the measurements of the personal nuclear accident dosimeters (PNAD). Additionally, portable survey instrument readings and measurements of the simulated biological samples are included. The FlatTop exercise (IER-253) tested only PNADs and did not include fixed nuclear accident dosimeters (FNAD). Previous PNAD results obtained in 2016 at the Godiva-IV exercise IER-148 were summarized in PNNL Measurement Results for the 2016 Criticality Accident Dosimetry Exercise at the Nevada National Security Site IER-148 (PNNL-26497). The results clearly indicated that the previous dose conversions were a historical legacy of the Hanford Site and corresponded closer to kerma dose (or first collision dose, and not to Hp(10) dose). The technical basis for PNAD dose was based on the Godiva-IV exercise and documented in A New Dose Calculation Methodology for New PNAD and FNAD Designs at PNNL (PNNL-27023). The configuration of the PNAD was described in these two documents. The FlatTop exercise was the first time PNNL tested this new dose calculation methodology. Results were generally favorable with some results conservatively over reported that fell above the performance criteria. The reported gamma dose results fell non-conservatively low because only the default parameters obtained from the Godiva-IV exercise were used, and because the OSL gamma dosimeter has an energy dependency. The results from the simulated biological samples were also favorable, and in several cases conservatively over reported.

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AP Tank Farm Exhauster Slipstream: Volume 2 Raw Analytical Data

As the Tank Operations Contractor for U.S. Department of Energy operations at the Hanford site in Washington State, Washington River Protection Solutions (WRPS) is responsible for managing highly radioactive wastes stored in tanks at Hanford. WRPS tests air-purifying respirator (APR) and powered air-purifying respirator (PAPR) chemical cartridges commonly used at Hanford Tank Farms to determine the period of time that the cartridges would provide adequate performance for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from any vapors exiting headspaces in the storage tanks. The Occupational Safety and Health Administration (OSHA) Standard promulgated in Title 29 of the Code of the Federal Regulations (CFR) 1910.134(d)(3)(iii)(b)(2) specifies that for protection against gases and vapors, employers shall implement a schedule for cartridges to ensure that change-outs occur before the end of service life. The change schedule can be based on objective information or data that ensures cartridge change-outs occur before the end of their service life.[2-5] The primary function of the WRPS Cartridge Test Program is to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford Tank Farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis and any recommendations. Volume 1 of this report summarizes data analysis of APR and PAPR cartridge testing on vapors from the AP tank farm exhauster. Previous testing of APR cartridges was conducted on the AP exhauster in June 2016. However, an AP exhauster upgrade was completed in September 2016. Two different APR cartridges from SCOTT Safety (Monroe, North Carolina) were assessed for the new AP exhauster source, along with two different PAPR cartridges—one from MSA Safety Inc. (Pittsburgh, Pennsylvania) and another from 3M (Maplewood, Minnesota). Volume 2 provides an introduction to the raw data, including analytical laboratory analysis results that supported the analysis and conclusions documented in Volume 1.

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis of Air-Purifying Respirator (APR) Cartridge Performance Testing on Hanford Tanks SX-101 and SX-104: Volume 2 - Raw Analytical Data

As the Tank Operations Contractor for U.S. Department of Energy operations at the Hanford site in Washington State, Washington River Protection Solutions (WRPS) is responsible for managing highly radioactive wastes stored in tanks at Hanford. To protect workers at Hanford Tank Farms, WRPS tests air-purifying respirator (APR) and powered air-purifying respirator (PAPR) chemical cartridges commonly used at the tank farms. The tests were conducted to determine the period of time the cartridges would provide adequate performance for APRs and PAPRs when workers are exposed to a mixture of Chemicals of Potential Concern (COPC) from any vapors exiting headspaces in the storage tanks. Occupational Safety and Health Administration (OSHA) Standard 29 Code of the Federal Regulations (CFR) 1910.134(d)(3)(iii)(b)(2) specifies that for protection against gases and vapors, employers shall implement a schedule for cartridges to ensure that change-outs occur before the end of service life. The change schedule can be based on objective information or data that ensures cartridge change-outs occur before the end of their service life. The primary function of the WRPS Cartridge Test Program is to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford Tank Farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis and any recommendations. This report summarizes data analysis of APR cartridge testing on headspace vapors from Hanford SX-101 and SX-104 single-shell tanks. Volume 1 of this report documents the testing, data analysis, results, conclusions, and recommendations resulting from the APR testing on SX-101 and SX-104 headspace vapors. Volume 2 provides an introduction to the raw data, including analytical laboratory analysis results that supported the analysis and conclusions documented in Volume 1.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on Hanford Tanks BY-108 and BY-110 Volume 2: Raw Analytical Data

As the Tank Operations Contractor for U.S. Department of Energy operations at the Hanford site in Washington State, Washington River Protection Solutions (WRPS) is responsible for managing highly radioactive wastes stored in tanks at Hanford. WRPS tests air-purifying respirator (APR) and powered air-purifying respirator (PAPR) chemical cartridges commonly used by workers at Hanford Tank Farms to determine the period of time that the cartridges would provide adequate performance for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from any vapors exiting headspaces in the storage tanks. The Occupational Safety and Health Administration (OSHA) Standard promulgated in Title 29 of the Code of the Federal Regulations (CFR) 1910.134(d)(3)(iii)(b)(2) specifies that for protection against gases and vapors, employers shall implement a schedule for cartridges to ensure that change-outs occur before the end of service life. The change schedule can be based on objective information or data that ensures cartridge change-outs occur before the end of their service life. The primary function of the WRPS Cartridge Test Program is to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford Tank Farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis and any recommendations. This report summarizes data analysis of APR and PAPR cartridge testing on BY-110 and BY-108 headspace vapors, respectively. Two different APR cartridges from SCOTT Safety (Monroe, North Carolina) were assessed for the BY-110 headspace vapors, and two different PAPR cartridges—one from MSA Safety Inc. (Pittsburgh, Pennsylvania) and another from 3M (Maplewood, Minnesota)—were assessed for the BY-108 headspace vapors. Volume 1 of this report documents the testing, data analysis, results, conclusions, and recommendations resulting from the cartridge testing of vapors from the BY-110 and BY-108 headspaces. Volume 2 provides an introduction to the raw data, including analytical laboratory analysis results that supported the analysis and conclusions documented in Volume 1.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗