Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HIP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

The influence of advanced processing on PWA 1480

High thermal gradient casting of PWA 1480 was evaluated as an avenue for reducing the size of casting porosity. Hot isostatic pressing (HIP) was also employed for the elimination of casting pores. An alternate to the standard PWA 1480 coating plus diffusion bonding aging heat treatment cycle was also evaluated for potential improvements in the properties of interest to the Space Shuttle Main Engine (SSME) application. Microstructural changes associated with the high thermal gradient casting process were quantified by measurement of the size and density of the casting porosity, the amount of retained casting eutectic, and dendrite arm spacings. The results of the advanced processing have shown an improvement in material microstructure due to high thermal gradient casting. Improved homogeneity of PWA 1480 is advantageous in providing an improved solution heat treatment window and, potentially, easier HIP. High thermal gradient casting improves fatigue life by reducing casting pore size. The alternate heat treatment improves the balance of strength and ductility which appears to improve low cycle fatigue life, but with a reduction in short time stress rupture life. Based upon these tests, hot isostatic pressing appears to afford further improvements in cyclic life, though additional evaluation is suggested. Development of the alternate heat treatment is not recommended due to the reduced stress rupture capability and the need to develop a new properties data base. High thermal gradient casting and HIP are recommended for application to single crystal castings.

Fritzemeier, L. G.↗

SiGe/Si heterojunction internal photoemission long-wavelength infrared detectors fabricated by molecular beam epitaxy

A new SiGe/Si heterojunction internal photoemission (HIP) long-wavelength infrared (LWIR) detector has been fabricated by molecular beam epitaxy (MBE). The detection mechanism of the SiGe/Si HIP detector is infrared absorption in the degenerately doped p+-SiGe layer followed by internal photoemission of photoexcited holes over a heterojunction barrier. By adjusting the Ge concentration in the SiGe layer, and, consequently, the valence band offset between SiGe and Si, the cutoff wavelength of SiGe HIP detectors can be extended into the LWIR (8-17-micron) regime. Detectors were fabricated by growing p+-SiGe layers using MBE on patterned p-type Si substrates. The SiGe layers were boron-doped, with concentrations ranging from 10 to the 19th/cu cm to 4 x 10 to the 20th/cu cm. Infrared absorption of 5-25 percent in a 30-nm-thick p+-SiGe layer was measured in the 3-20-micron range using a Fourier transform infrared spectrometer. Quantum efficiencies of 3-5 percent have been obtained from test devices in the 8-12-micron range.

Lin, True-Lon↗

Effect of altered sensory conditions on multivariate descriptors of human postural sway

Multivariate descriptors of sway were used to test whether altered sensory conditions result not only in changes in amount of sway but also in postural coordination. Eigenvalues and directions of eigenvectors of the covariance of shnk and hip angles were used as a set of multivariate descriptors. These quantities were measured in 14 healthy adult subjects performing the Sensory Organization test, which disrupts visual and somatosensory information used for spatial orientation. Multivariate analysis of variance and discriminant analysis showed that resulting sway changes were at least bivariate in character, with visual and somatosensory conditions producing distinct changes in postural coordination. The most significant changes were found when somatosensory information was disrupted by sway-referencing of the support surface (P = 3.2 x 10(-10)). The resulting covariance measurements showed that subjects not only swayed more but also used increased hip motion analogous to the hip strategy. Disruption of vision, by either closing the eyes or sway-referencing the visual surround, also resulted in altered sway (P = 1.7 x 10(-10)), with proportionately more motion of the center of mass than with platform sway-referencing. As shown by discriminant analysis, an optimal univariate measure could explain at most 90% of the behavior due to altered sensory conditions. The remaining 10%, while smaller, are highly significant changes in posture control that depend on sensory conditions. The results imply that normal postural coordination of the trunk and legs requires both somatosensory and visual information and that each sensory modality makes a unique contribution to posture control. Descending postural commands are multivariate in nature, and the motion at each joint is affected uniquely by input from multiple sensors.

NASA Discipline Neuroscience↗

The Effect of Increasing Mass upon Locomotion

The purpose of this investigation was to determine if increasing body mass while maintaining bodyweight would affect ground reaction forces and joint kinetics during walking and running. It was hypothesized that performing gait with increased mass while maintaining body weight would result in greater ground reaction forces, and would affect the net joint torques and work at the ankle, knee and hip when compared to gait with normal mass and bodyweight. Vertical ground reaction force was measured for ten subjects (5M/5F) during walking (1.34 m/s) and running (3.13 m/s) on a treadmill. Subjects completed one minute of locomotion at normal mass and bodyweight and at four added mass (AM) conditions (10%, 20%, 30% and 40% of body mass) in random order. Three-dimensional joint position data were collected via videography. Walking and running were analyzed separately. The addition of mass resulted in several effects. Peak impact forces and loading rates increased during walking, but decreased during running. Peak propulsive forces decreased during walking and did not change during running. Stride time increased and hip extensor angular impulse and positive work increased as mass was added for both styles of locomotion. Work increased at a greater rate during running than walking. The adaptations to additional mass that occur during walking are different than during running. Increasing mass during exercise in microgravity may be beneficial to increasing ground reaction forces during walking and strengthening hip musculature during both walking and running. Future study in true microgravity is required to determine if the adaptations found would be similar in a weightless environment.

DeWitt, John↗

Preliminary Results of Bisphosphonate ISS Flight Experiment

Bone loss has been recognized as a potential problem from the beginning of human spaceflight. With the spaceflight missions lasting 6 months to potentially 3 years or longer this issue has assumed increased significance. Detailed measurements from the Mir and ISS long duration missions have documented losses in bone mineral density (BMD) from the total skeleton and critical sub-regions. The most important losses are from the femoral hip averaging about -1.6%/mo integral to -2.3%/mo trabecular BMD. Importantly these studies have documented the wide range in individual response from -0.5 to -5%/mo in BMD. Given the small size of any expedition crew, the wide range of responses has to be considered in the implementation of any countermeasure. Assuming that it is unlikely that the susceptibility for bone loss in any given crewmember will be known, a suite of bone loss countermeasures will likely be needed to insure protection of all crewmembers. The hypothesis for this experiment is that the combined effect of anti-resorptive drugs plus the standard in-flight exercise regimen will have a measurable effect on preventing space flight induced bone loss and strength and will reduce renal stone risk. To date, 4 crewmembers have completed the flight portion of the protocol in which crewmembers take a 70-mg alendronate tablet once a week before and during flight, starting 17 days before launch. Compared to previous ISS crewmembers (n=14) not taking alendronate, DXA measurements of the total hip BMD were significantly changed from -1.1 0.5%/mo to 0.04 0.3%/mo (p<0.01); QCT-determined trabecular BMD of the total hip was significantly changed from -2.3 1.0%/mo to -0.3 1.6%/mo (p<0.01). Significance was calculated from a one-tailed t test. While these results are encouraging, the current n (4) is small, and the large SDs indicate that while the means are improved there is still high variability in individual response. Four additional crewmembers have been recruited to participate in this experiment, with expected completion of these flights by late 2011.

LeBlanc, Adrian↗

Bone Density Following Three Years of Recovery from Long-Duration Space-Flight

Bone loss during long-duration space flight is well recognized, but the long-term implications on bone health following return from flight remain unclear. Among US crew who were involved in long-duration missions in space (Mir and ISS), we have previously shown that at approximately 12 months following return, men, but not women, had BMD values at most sites that were still lower than would be expected had they not been exposed to a prolonged period of microgravity. We now extend our observations to 3 years of follow-up post-flight. Using their age, pre-flight BMD and follow-up time, post-flight BMD values for each US crew were predicted based on the model developed from the community sample. We found BMD measures to be either stable or improve by 3 years relative to their immediate post-flight BMD, however only total hip BMD still remains significantly lower than would be expected had they not been exposed to microgravity. Among male US crew, who have had their BMD measured following at least 3 years of recovery post long-duration flight, they continue to have lower BMD at the hip than would be expected, raising potential concerns regarding future hip fracture risk.

Amin, S.↗

Antiresorptive Treatment for Spaceflight Induced Bone Atrophy - Preliminary Results

Detailed measurements from the Mir and ISS long duration missions have documented losses in bone mineral density (BMD) from critical skeletal sub-regions. The most important BMD losses are from the femoral hip, averaging about -1.6%/mo integral to -2.3%/mo trabecular. Importantly these studies have documented the wide range in individual BMD loss from -0.5 to -5%/mo. Associated elevated urinary Ca increases the risk of renal stone formation during flight, a serious impact to mission success. To date, countermeasures have not been satisfactory. The purpose of this study is to determine if the combined effect of anti-resorptive drugs plus the standard in-flight exercise regimen will have a measurable effect on preventing space flight induced bone loss (mass and strength) and reducing renal stone risk. To date, 4 crewmembers have completed the flight portion of the protocol in which crewmembers take a 70-mg alendronate tablet once a week before and during flight, starting 17 days before launch. Compared to previous ISS crewmembers (n=14) not taking alendronate, DXA measurements of the spine, femur neck and total hip were significantly improved from -0.8 +/- 0.5%/mo to 1.0 +/- 1.1%/mo, -1.1 +/- 0.5%/mo to -0.2 +/- 0.3%/mo, -1.1 +/- 0.5%/mo to 0.04 +/- 0.3%/mo respectively. QCT-determined trabecular BMD of the femur neck, trochanter and total hip were significantly improved from -2.7 +/- 1.9%/mo to -0.2 +/- 0.8%/mo, -2.2 +/- 0.9%/mo to -0.3 +/- 1.9%/mo and -2.3 +/- 1.0%/mo to -0.2 +/- 1.8%/mo respectively. Significance was calculated from a one-tailed t test. Resorption markers were unchanged, in contrast to measurements from previous ISS crewmembers that showed typical increases of 50-100% above baseline. Urinary Ca showed no increase compared to baseline levels, also distinct from the elevated levels of 50% or greater in previous crews. While these results are encouraging, the current n (4) is small, and the large SDs indicate that, while the means are improved, there is still high variability in individual response. Three additional crewmembers have been recruited to participate in this experiment, with expected completion in late 2011.

LeBlanc, Adrian↗

Visible-Infrared Hyperspectral Image Projector

The VisIR HIP generates spatially-spectrally complex scenes. The generated scenes simulate real-world targets viewed by various remote sensing instruments. The VisIR HIP consists of two subsystems: a spectral engine and a spatial engine. The spectral engine generates spectrally complex uniform illumination that spans the wavelength range between 380 nm and 1,600 nm. The spatial engine generates two-dimensional gray-scale scenes. When combined, the two engines are capable of producing two-dimensional scenes with a unique spectrum at each pixel. The VisIR HIP can be used to calibrate any spectrally sensitive remote-sensing instrument. Tests were conducted on the Wide-field Imaging Interferometer Testbed at NASA s Goddard Space Flight Center. The device is a variation of the calibrated hyperspectral image projector developed by the National Institute of Standards and Technology in Gaithersburg, MD. It uses Gooch & Housego Visible and Infrared OL490 Agile Light Sources to generate arbitrary spectra. The two light sources are coupled to a digital light processing (DLP(TradeMark)) digital mirror device (DMD) that serves as the spatial engine. Scenes are displayed on the DMD synchronously with desired spectrum. Scene/spectrum combinations are displayed in rapid succession, over time intervals that are short compared to the integration time of the system under test.

Bolcar, Matthew↗

A Better ARED Squat

The 0-G ARED squat under loads the legs relative to the 1g ARED squat. In 1g the knee extensor/flexor muscles are primarily engaged due to the body's center of gravity is behind the knees during the motion of the squat. As body weight does not play a sufficient role 0 G, a crewmember's load exposure is limited by the load delivered by ARED through the exercise bar. Prescription loads for lowerbody resistance exercise in microgravity aim to include 1-G exercise bar load in addition to the crewmember's Earth body weight (BW); however, pressure points from the bar and the 1BW increased load at the shoulders translating to higher loads on the back have been a historical limitation for shoulders, requiring a decrease in exercise load at the start of the mission. Analogous to crewmembers, bed rest subjects report limitations of exercising with high loads on the back while performing squats on the horizontal exercise fixture (HEF), a custom exercise device that serves as an analog to 0-G ARED. Improvements for increasing loads on the HEF squat were suggested by distributing total exercise load between the hips and the bar1. The same is recommended for the 0-G ARED squat, with using current equipment on the ISS, which include the T2 running harness and T2 bungees. Quantification of this improvement has been accessed through computational modeling. The purpose of this study is to characterize joint torque during a squat with a distribution in exercise load on the ARED in 0 G. The analysis used existing models from NASA's Digital Astronaut Project. The biomechanics squat model was integrated with the ARED model and T2 bungees. The spring constant for the bungees were derived from ground testing. Forward dynamic simulation was performed for various conditions including anchor point attachments on the footplate of the ARED, bar load, hip load, and gravitational environment. The model confirms joint torques at knees is lower relative to 1G conditions primarily because the load delivery system is just with the exercise bar in 0 G. By distributing partial loads through use of the bungees to the hips joint-torque profiles were altered during a squat and provided options to enhance targeting lower-body loading in aims as for an improved countermeasure.

Caldwell, E. E.↗

Influence of Load Profile on Biomechanics of the Squat and Deadlift

Long duration space travel will expose astronauts to extended periods of reduced gravity. Since gravity is not present to assist loading, astronauts will use resistive and aerobic exercise regimes for the duration of the space flight to counteract the effect reduced gravity has on the body. Astronauts will exercise on a flywheel based device on the second Orion Exploration Mission (EM2). The effect that the flywheel load profile has on biomechanics is unknown when compared to free weights or a simulated free weight profile. The purpose of this evaluation is to compare the differences in lower body kinematics and kinetics between the flywheel and free weight profile. Test subjects were instrumented with reflective markers for motion capture data collection while exercising on the Device for Aerobic and Resistive Training (DART) prototype developed by TDA Research, Inc. of Wheat Ridge, CO. Exercises performed were either the squat while wearing a harness or deadlift while grasping a T-bar, both of which interfaced with the DART through a rope cable. The DART, a motorized device controlled via software, is capable of producing different load profiles. Profiles include simulated free weights with adjustable eccentric overload capability and flywheel. Test variables included the applied device load and the load profile, both set through the DART software interface. Motion capture data was collected with a 12 camera system (Smart-DX, BTS Bioengineering, Brooklyn, NY). Bilateral ground reaction force data were collected with force plates (P6000, BTS Bioengineering). DART cable force was recorded through an internal load cell. Data was collected from a total of four test subjects. The three repetition maximum was determined for each test subject for both squat and deadlift. High, medium and low loads were determined based on this maximum. The test subject performed five repetitions of each exercise at each load and each test trial was repeated twice. Cadence was controlled during exercising. Biomechanical data were used to drive the models utilizing the OpenSim software platform. Subject specific models were scaled to match the anthropometrics of the test subjects and used to estimate the peak joint angle, joint range of motion, the peak joint moment and the joint moment impulse of the lower extremity joints and the lumbar joint.These are preliminary results because the data analysis is ongoing. There was a lot of inter-subject variability, however, in general, there was a greater peak lumbar flexion angle for the flywheel squat exercise. There was a trend towards a greater range of motion at the hip for the squat exercise with free weight. There was also a greater hip extension, lumbar extension and ankle plantar flexion impulse moment during the squat exercise with free weight. During the deadlift exercise, the peak knee flexion angle and peak knee extension moment were greater when using the free weight profile. For deadlift, the hip extension, lumbar extension and ankle plantar flexion impulse moment tended to be greater with the free weight profile. Overall, the kinematic and kinetic outcomes for the flywheel profile were either statistically the same as free weight profile in many cases, significantly reduced in a few cases, and rarely higher.

Bioengineering↗

Next Generation Durability and Damage Tolerance to Support Certification of Flight Hardware

Durability and Damage Tolerance (D&DT), as currently applied to flight hardware throughout the Agency, is based on continuum and similitude assumptions and does not consider local material properties, environments and responses. These limitations impact our ability to support certification of new component designs, material systems and manufacturing approaches. The primary concern in this Engineering R&A plan is related to the imminent proliferation of parts produced by additive manufacturing (AM). These parts are being advocated by NASA’s suppliers for use on a myriad of flight hardware because of their design flexibility and cost advantages. AM provides opportunities to reduce part counts through complex geometry and reduce manufacturing costs of low volume parts. However, AM materials have some notable metallurgical and microstructural differences compared to traditionally fabricated materials. One of the challenges for the acceptance of AM is the greater tendency for a deleterious defect state, most commonly in the form of porosity, to exist in AM parts. Though this defect state is typically reduced through a hot isostatic pressing (HIP) processing step, the structural performance risks associated with the remaining defects and HIP-healed features is not known. Potential fracture control issues that must be resolved stem from the real possibility that an unhealed defect or a closed defect with less than pristine strength remains at a fracture critical location after HIP. As a result, NASA and the entire aerospace community have been confronted with the need to develop a robust and relevant certification methodology to enable safe implementation of these components. The present work is an important step toward positioning NASA to credibly respond to vendors’ push to implement this new AM materials technology by improving our understanding of AM processing and performance and transitioning that research-based understanding to next-generation engineering capabilities.

Edward H Glaessgen↗

Reduced Cost NiTi-Alloy Bearings Made Via Near Net Shape Powder Metallurgy Processes

NiTi alloys are emerging as an attractive bearing race material for bearings exposed to high static loads and highly corrosive environments. One obstacle yet to be overcome is the intrinsically high relative cost of these materials compared to traditional bearing steels. Traditional net-shape powder metallurgy methods, such as cold-press and sinter, are not applicable to NiTi alloys because they require hot isostatic pressing (HIP) to achieve full density, flaw free microstructures. Recently, innovative powder metallurgy processing has been successful in forming bearing ring blank shapes through the use of geometrically tailored HIP containers. Microstructural evaluations show that ring blanks made from this process are comparable to material made using conventional HIP containers while substantially reducing material usage.

bearings↗

Systematic Phase Curve Study of Known Transiting Systems from Year One of the TESS Mission

We present a systematic phase curve analysis of known transiting systems observed by the Transiting Exoplanet Survey Satellite (TESS) during year one of the primary mission. Using theoretical predictions for the amplitude of the planetary longitudinal atmospheric brightness modulation, stellar ellipsoidal distortion and Doppler boosting, as well as brightness considerations to select targets with likely detectable signals, we applied a uniform data processing and light-curve modeling framework to fit the full-orbit phase curves of 22 transiting systems with planet-mass or brown dwarf companions, including previously published systems. Statistically significant secondary eclipse depths and/or atmospheric brightness modulation amplitudes were measured for HIP 65A, WASP-18, WASP-19, WASP-72, WASP-100, WASP-111, WASP-121, and WASP-122/KELT-14. For WASP-100b, we found marginal evidence that the brightest region of the atmosphere is shifted eastward away from the substellar point. We detected significant ellipsoidal distortion signals in the light curves of HIP 65A, TOI-503, WASP-18, and WASP-30, with HIP 65A, TOI-503 and WASP-18 also exhibiting Doppler boosting. The measured amplitudes of these signals agree with the predictions of theoretical models. Combining the optical secondary eclipse depths with previously published Spitzer 3.6 and 4.5 μm measurements, we derived dayside brightness temperatures and visible-light geometric albedos for a subset of the analyzed systems. We also calculated updated transit ephemerides combining the transit timings from the TESS light curves with previous literature values.

Ian Wong↗

Hot Isostatic Pressing for Reduction of Defects in Additively Manufactured Inconel-718 Preliminary Simulation Approach and Results

Selective laser melting (SLM) of Inconel-718 (IN718) is a promising advanced manufacturing technology; however, challenges exist for fracture-critical parts where pores induced during the manufacturing process reduce fatigue life of the material. Hot isostatic pressing (HIP) is a common post processing technique used to reduce the part porosity by exposing parts to high temperature and pressures. Pore closure depends on the pore shape, trapped gas, and HIP parameters, and the process can only be optimized by understanding the effect of these variables. An analysis capability is described to better understand the conditions necessary for pore closure, and the effect of several variables on porosity are explored and compared to a baseline case. The importance of valid material response models is identified as a significant factor in model accuracy; especially the creep material response model which, in the baseline case, predicts that creep strain accounts for 87.7% of the total strain at the conclusion of the HIP cycle. Lessons learned are described, in addition to future work including model validation.

Joshua M Fody↗

Heat Treatment Optimization of Laser Powder Bed Fusion Additive Manufacture C103

Laser Powder Bed Fusion (L-PBF) and Laser Powder Directed Energy Deposition (LP-DED) additive manufacture C103 is in development for propulsion applications that operate under extreme environments. The standard post-process heat treatment has called for vacuum stress relief, however, depending on the application or certification requirements hot isostatic press (HIP) may be required. Although C103 density responds well to HIP the associated grain growth results in a reduction in mechanical properties. An investigation was conducted to look at the potential benefit of leveraging HIP followed by rapid cooling to minimize grain growth. A series of heat treatment schedules varying temperature and pressure were conducted followed by microstructural and mechanical characterization.

Additive Manufacturing↗

Unraveling the Mechanics: Computational Modeling of Residual Stresses in U10Mo Fuel with Aluminum Cladding

LEU (Low Enriched Uranium) plate-type fuel elements consist of a high-density, low-enrichment U–Mo alloy-based fuel foil encapsulated in an aluminum cladding and is fabricated through the Hot Isostatic Pressing (HIP) technique. Understanding the mechanism of possible failure modes of nuclear fuel is critical to mitigate potential consequences. One of the major contributing factors in various failure modes is stress and it greatly affects the integrity under temperature, pressure, and irradiation. These stresses could originate from various sources, including manufacturing, and operation, and can lead to deformation, cracking, or even complete failure of fuel elements. This study focuses on the development of a computational model that accurately predicts the residual stresses generated in the U10Mo fuel during fabrication. It has been observed that cladding creep has a substantial impact on the residual stresses in the U10Mo fuel post the HIP fabrication process. Furthermore, during the HIP bonding process the fuel plate system is heated to a temperature of 560 oC and as a result, the aluminum cladding transitions from (Al 6061-T6 to -O). This presents a challenge in capturing the change in material properties accurately. Therefore, a temperature dependent creep model such as hyperbolic sine creep model is considered to estimate the creep properties of the Aluminum cladding. The proposed calibrated creep model accurately predicts the residual stresses in the U10Mo fuel foil and agrees well with the experiments.

42 ENGINEERING↗

Evaluation of U10Mo Fuel Plate Performance Modeling Over Hot Isostatic Press and Hydraulic Bending for MURR DDE Plates

The United States High Performance Research Reactor Program’s objective is to reduce the amount of highly enriched uranium currently implemented in research reactors. The conversion of these research reactors requires designing a monolithic U10Mo plate fuel, with the fuel plate geometry being dependent on each research reactor. The process of forming the plates includes a hot isostatic pressing (HIP) to manufacture a prototypic plate. In the case of the Missouri University Research Reactor (MURR) design demonstration element (DDE) plate manufacture, plates that have been through HIP are then curved using dies and a hydraulic press to impart the desired curvature. Both fabrication processes impart residual stresses into each fuel plate region, with the curvature of the plates taking some regions of the fuel plate up to their material yield stresses, accompanied by plastic strain. The amount of plastic strain and stress imparted onto each MURR DDE plate is determined by the radius of curvature, thickness of each region, and overall width of the fuel plates. Furthermore, this work aims to predict the yield stresses and strain using ABAQUS to simulate the proposed fabrication process of the MURR DDE plates, accompanied by discussion over the stresses and strains as to their relation to nuclear fuel performance and the impact they will have during early irradiation.

ABAQUS↗

Microstructural Evolution and ORR Activity of Nanocolumnar Platinum Thin Films with Different Mass Loadings Grown by High Pressure Sputtering

Nanocolumnar platinum thin films (Pt-TFs) with different Pt mass loadings were grown by high pressure sputtering (HIPS) and investigated as oxygen reduction reaction (ORR) electrocatalysts for polymer electrolyte membrane fuel cell applications. Mass loading was controlled by changing the sputter deposition time. A cauliflower-like columnar microstructure was achieved by depositing the Pt-TFs onto a microporous layer (MPL)-like surface composed of carbon particles in order to mimic catalyst-coated gas diffusion electrodes. Microstructural evolution of HIPS Pt-TFs and their ORR activity were investigated. Electrochemical characterization of the nanocolumnar Pt-TFs was performed by cyclic voltammetry and rotating disk electrode measurements on Pt-TF/MPL-like-layer/glassy-carbon samples in an aqueous perchloric acid electrolyte. The electrochemically active surface area increased from 18 to 39 m 2 g –1 as the Pt mass loading was decreased. Specific activity of the films was similar (~600 μA cm –2 ) for all Pt mass loadings, due to the similar nanoparticle sizes of ~5 nm as observed by transmission electron microscopy and X-ray diffraction. Furthermore, mass activity of the films increased from 0.11 to 0.26 A mg –1 as the Pt mass loading was decreased, which is an indication of the effective Pt utilization and better access through the catalyst layer at lower Pt mass loadings.

08 HYDROGEN↗