At least 289 records · Page 16

Utilizing commercial heating, ventilating, and air conditioning systems to provide grid services: A review

The modern power grid faces multiple challenges due to an increase in the adoption of renewable generation, such as dynamically balancing supply and demand at different time scales. Demand side management in buildings plays a vital role in achieving this balance because buildings can provide grid services through a variety of building assets. However, the development of grid-interactive, efficient buildings is still in its infancy, and a systematic and holistic understanding of grid service delivery strategies in terms of energy efficiency, load shifting, load shedding and load modulating is still limited. This paper is a comprehensive review of the development and application of building-level control strategies for utilizing heating, ventilating, and air conditioning systems to provide grid services. These strategies have been investigated through numerical and experimental studies. Control algorithms, such as heuristic rule-based control and model-based control, have been used to enable the automatic control delivery of grid services. The advantages and disadvantages of the strategies are summarized and discussed. Finally, research trends are also identified, which include considering predicted mean vote-based and occupant-based thermal comfort, modeling of occupant behavior, integrating power grid operations with building control, and combining different demand flexibility modes in the control design.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Achieving geometric accuracy in FFT-based micromechanical models using conformal grid

Owing to its efficiency, simplicity and robustness, the FFT-based method has become the standard for computation of mechanical fields in a heterogeneous periodic unit cell. One of the main disadvantages of the FFT-based method is the inaccurate representation of the initial microstructure on a regular grid of voxels, which can be alleviated through the use of distorted initial grids. Here, in this paper, a method for generation of distorted initial grids conforming to the microstructural features (e.g. straight/curved boundaries) is proposed. The method determines the positions of the grid nodes in the initial configuration by solving a system of springs connecting the nodes. Microstructures consisting of layers, Voronoi tessellation and circular/spherical inclusions are considered, and mechanical fields simulated using the FFT-based method. It is found that distorted initial grids, conforming to the microstructural features, lead to more accurate mechanical fields in comparison to the corresponding non-distorted initial grid solution. The effect of initial grid distortion on the convergence of the FFT-based method is analyzed and discussed.

36 MATERIALS SCIENCE↗

Grid Forming Fast Frequency Response for PMSG-Based Wind Turbines

Electric power systems are undergoing a rapid transition from fuel-based generation using synchronous generators to renewable generation interfaced by power electronics. In this context, a key challenge is using renewable generation with limited controllability to contribute to power system stability. In this work, we investigate grid-forming control of permanent magnet synchronous generator (PMSG) wind turbines. The proposed control and curtailment strategy supports the entire spectrum of standard functions of grid-following (e.g. maximum power point tracking (MPPT) and grid-forming control (e.g., primary frequency control) without explicit mode switching. A detailed case study is used to compare the performance of the proposed control at operating points corresponding to MPPT and frequency control with standard grid-forming and grid-following controls. Further, the results demonstrate that (i) the proposed energy balancing grid forming control is self-synchronizing in MPPT mode, (ii) the (limited) energy storage and controllability of wind turbines can be adequately utilized to provide grid support, and (ii) the proposed control exhibits good performance under variable wind speeds and does not result in a significant increase of wind turbine fatigue loads.

17 WIND ENERGY↗

An Ultra-Fast Inrush-Current-Free Startup Method for Grid-tie Inverter without Voltage Sensors

This paper proposes an ultra-fast inrush-currentfree startup method for grid-tie inverters without voltage sensors and phase-locked loop (PLL). Traditionally, the grid-tie inverter needs the voltage measured from points of common couplings (PCC) to generate the phase angle via PLL for inverter pulsewidth- modulation (PWM) signals. The startup procedure is slow and inrush current occurs if the initial PWM does not match the unknown grid voltage well. This paper proposes a startup method that only uses measured inverter ac currents to generate the initial PWM by controlling the current to zero. The generated PWM pattern can be used to reproduce the real grid voltage regardless of the grid impedance. The zero-crossing points of the grid voltage are detected and then used for grid synchronization. The proposed startup procedure only needs a few cycles (16.67 ms/cycle) to reliably synchronize the inverter to the grid without any inrush current. Simulation and experimental results are presented to verify the effectiveness of this control strategy.

He, Yuchen↗

A 20-kW DC Oak Ridge Converter with Integrated AC & DC Sources for Grid Services and Energy Storage Systems

This paper proposes a wireless power transfer (WPT) platform with integrated energy conversion that has the capability for 1) recharging the energy storage systems (ESSs) from the grid systems, including renewable energy sources such as wind, solar, etc., 2) off grid systems recharging the ESSs from dc grid systems, 3) grid recharging of electric vehicles (EVs), and 4) off grid recharging of EVs from ESSs. The unique aspect of the method is the use of multi-interface power electronic converter for the grid and ESSs and EVs that can support a range of applications with ac / dc and dc / dc energy conversion ability in a single converter system. The key enabling technology to achieve these functionalities is Oak Ridge Converter (ORC) with polyphase coupler coil system both developed at ORNL. This new technology enables higher power density WPT systems while allowing the coils to interface from ac grid at 60 Hz frequency or dc source directly merging with 85 kHz operating frequency of switching component. The experimental results of the proposed system are presented for 20 kW output power with the system overall efficiency around 95.4% from dc source and 93% overall efficiency from ac grid achieving 9-10% current total harmonic distortion (THD) and 0.98-0.99 power factor (PF).

Asa, Erdem↗

Enhanced Frequency Support Scheme of Generic Inverter-Based Resource Models for Renewable-Dominated Power Grids

The frequency response of SG-dominated power grids is predictable ahead of an occurrence of a frequency event because the frequency response of SGs is consistent, and it can be inferred from the swing equation [1]. However, increasing the portion of IBRs in an SG-dominated power grid might make the characteristics of the conventional power grids no longer valid because this changing resource mix affects grid dynamics and controls [2]. Thus, maintaining these characteristics greatly benefits the control and operation of the power grids with high penetration of IBRs. To maintain these characteristics in IBR-dominated power grids, IBRs should have frequency response capability similar to that of an SG. The WECC modeling validation subcommittee has developed generic IBR models for large system planning [3]-[5]. These models can represent various vendors' dynamic behavior for WTG, PV, and ESS [5]. The current generic IBR models approved by WECC can provide frequency response only from droop control loops in REPC models [6], [7]. The contribution of the loops is proportional to the frequency deviation from the nominal frequency. Thus, it presents an insufficient contribution to arrest frequency variation compared to the frequency response of SGs because it allows a high ROCOF in the early stage of frequency events. This shortfall will become greater as the PL of IBRs increases in power grids. Controller enhancement for the generic IBR models is required to secure the frequency stability under high PL of IBRs as in the SG-dominated power grids. This paper proposes a control extension for the generic IBR models to enhance the frequency support capabilities and discusses the classification of frequency support for the different types of IBR considering their operating constraints. An inertial control scheme is implemented in the REPC and REEC models of the generic IBR models to achieve these objectives. The inertial control scheme includes the following stages: Control area data acquisition, inertia time constant estimation, IBR-related constraint check, IBR contribution determination, and inertial response provision. In the scheme, a REPC acquires control area data from a system operator and estimates a total inertia time constant for the control area the applicable IBR power plant belongs. Then, the estimated inertial time constant is transferred to each IBR controller—REEC—within the power plant. Each REEC checks the availability of applicable IBR for inertial response participation. If the IBR is available, the REEC amplifies the estimated inertial time constant to utilize it for inertial response provision. In this way, the proposed inertial response scheme extends the functionality of the generic IBR models to provide SG-like frequency response within their constraints. Various scenarios considering different IBR types, IBR penetration levels, and frequency control schemes were simulated and compared in an IEEE 39-bus system using PSCAD simulator to verify the effectiveness of the proposed scheme.

Kim, Jinho↗

Smart Inverters for Seamless Reconnection of Isolated Residential Microgrids to Utility Grid

This paper proposes an approach to achieve seamless reconnection of isolated residential microgrids to utility grid. Any abnormal condition on the grid side results in isolating the residential microgrid from utility grid, and giving the full responsibility of supplying household loads to local distributed generation (DG) units. However, after resolving the abnormal condition on the grid side, the residential microgrid needs to seamlessly reconnect to the main grid. To this end, a seamless transition algorithm is presented which monitors the system condition in real time, and coordinates the operation of all inverter-based DG units in residential microgrid before reconnection to the main grid. A modified control scheme is proposed for single-phase inverters which turns them into smart inverters enable to interact with seamless transition algorithm. The proposed approach synchronizes each phase voltage with its respective grid-side voltage in order to seamlessly reconnect the residential microgrid to the main grid. Case study results are carried out in PSCAD/EMTDC environment to verify the validity of proposed method.

Pilehvar, Mohsen S.↗

Grid Parameters and Voltage Estimation Approach Integrating Data-Driven Converter Model

With Measurements of grid voltage and current are essential for the optimal operation of the grid protection and control (P&C) systems. Grid parameters vary through time during the faults and especially in the converter interfaced resources (CIRs) rich power grid, and thus accurate estimation is critical to avoid the mis-operation of the P&C systems. In this paper, a moving horizon estimation (MHE) as an observer is devised and applied to estimate the grid line parameters and grid voltages for protection enhancement. Due to the proprietary and confidentiality of CIRs, the proposed approach uses the black-box model to represent their dynamics. Leveraging the easily accessible measurements of output current from the black-box model of CIR and voltage at the point of common coupling, the proposed method estimates the grid impedance and grid voltage during normal and faulty operating conditions. The performance shows that the optimization-based observer was able to closely observe the accurate states and parameters, which can be utilized by the P&C systems.

Subedi, Sunil↗

Communication Network Layer State Estimation Measurement Model for a Cyber-Secure Smart Grid

Network communication has been proven to be a very important tool and a key factor in the recent development and progress of the power grid operation. It is also considered as the foundation for the smart grid because information and communication are integrated into electricity distribution to achieve reliable and accurate knowledge of the power grid. In previous years, absorbing energy from substations and delivering it to customers was the only type of interaction we knew between utility companies and customers. Presently, the growing connections of small distributed generation units caused by the cost reduction of most of the technologies used in generation and storage of electrical energy, along with the potential benefits of renewable energy have pushed many researchers to look into the improvement of information and communication technologies (ICT) in order to ensure a bidirectional flow of power and data. Moreover, the evolution of information and communication technologies and its applications to smart grid have converted the smart grid into a cyber-physical system where vulnerabilities and additional security challenges such as cyber-threats and cyber-attacks have emerged. Previously, we have demonstrated that using machine learning-based processing on data gathered from communication networks and the power grid was a promising solution for detecting cyber threats by implementing a co-simulation of cyber-security for cross-layer strategy. Since the majority of the challenges observed can only be solved in the network communication layer, we present in this work a physics-based state estimation model of the communication network system towards enhanced cyber-physical security of the smart grid. Information integration with the previously developed machine learning model is developed, providing a enhanced cyber-physical security application for the smart grid. Easy-to-implement model, without hard-to-derive parameters, highlight potential aspects of the model for real-life applications.

Mathieu, Reynold↗

test-grid-buildouts [SWR-23-112]

Test-grid-buildouts is a set of notebooks for creating buildouts of synthetic transmission grids with various levels of renewable energy. Workflows can be used to augment various test grid with varying levels of wind/solar generation. Aggregated renewable energy time series (actuals and scenarios) at grid buses can then be used for various transmission grid operation problems. Highly customizable workflow consists of parsing of synthetic grid files, setting up SAM & reV simulations, application of exclusion masks, creating of custom renewable generators on the grid, aggregating of power time series, and writing of modified grid description files.

Satkauskas, Ignas↗

Modeling the Functional Forms of Grid Disturbances

This report introduces a functional form that may be used to quantitatively predict the impacts of new grid tools and changing system qualities on the likelihoods, durations, and depths of various grid disturbances. Each disturbance scenario is modeled to have three component stages—avoidance, reactance and recovery, which together parametrically estimate one disturbance’s impacts. The modeled scenario is then placed and replicated within an analysis period to represent the likelihood or frequency of the scenario and its consequent impacts. Whereas analysts have struggled to define and apply metrics for grid resilience, the functional form introduced by this report shares units of measurement with accepted grid-status measures (e.g., numbers of customers currently experiencing a service outage). Furthermore, the integrated and averaged functional form over an analysis period provides a meaningful normalized performance metric (e.g., customer outage minutes per year) that is ultimately independent of the duration of the period of. The approach may be applied similarly regardless of the severity or frequency of the disturbances that are being analyzed. Because metrics can be chosen to be identical in both the hypothetical future and the actual historical past, the historical past eventually becomes the test of the future predictions, at least in a statistical sense. The authors originally developed this approach to facilitate analysis of the effects of transactive energy (TE) systems effects on electric power grid resilience. TE systems invite energy suppliers and consumers to actively collaborate toward the discovery of, and their responses to, the locational value of energy. The findings from this process are often embodied as energy prices, the dynamics of which indicate the locational value of energy and can further represent important grid service needs. While some academic papers claim to quantify the value of a specific TE system design toward grid resilience, the answer, in general, has been elusive. Not only do multiple and conflicting definitions of resilience and reliability exist, but countless TE systems are being invented. We conclude the following: (1) The ideal analysis should harmonize rather than differentiate resilience and reliability. Therefore, this report uses the more general term disturbance whenever the overloaded terms resilience and reliability can be avoided. (2) The effectiveness of TE systems must be mapped to underlying qualities of a TE system, thereby avoiding presumptions that every TE design offers similar advantages. The authors seek to evaluate the parametric effects of TE system qualities (e.g., spatial granularity, granularity of time steps, length of future prediction horizon) on avoiding, reacting to, and recovering from grid disturbances. Furthermore, any advantages (or disadvantages) must be fairly compared with the many alternative tools, systems, and strategies that might offer comparable benefits.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mapped Moments to a Cartesian Grid (MMCG) Value-Added Product Report

Objective analysis (OA) is a method of mapping unstructured data to a structured grid. In the context of scanning radar data, OA is used to interpolate data in antenna coordinates (range, azimuth, and elevation) onto a regularly spaced Cartesian grid (Trapp and Doswell 2000). The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s Mapped Moments to a Cartesian Grid (MMCG) Value-Added Product (VAP) uses the Python ARM Radar Toolkit (Py-ART), a data model-driven interactive architecture for working with weather radar data, to map the data to a Cartesian grid (Helmus and Collis 2016). MMCG, with Py-ART built in, has the ability to take radar data in antenna coordinates and map the gates to a Cartesian grid using inverse distance weight functions such as Cressman (square) and Barnes (exponential), but also can filter the data during the interpolation. MMCG also allows arbitrary formulations for the radius of influence, which are matched to particular radar scanning strategies. This creates a complex parameter space for optimizing the retention of storm structure detail while minimizing artifacts. MMCG takes data processed with ARM’s Corrected Precipitation Radar Moments in Antenna Coordinates (CMAC) VAP and maps it to a Cartesian grid as the output product. A variety of fields that have been mapped to the Cartesian grid are then saved to plots to complement each grid file.

54 ENVIRONMENTAL SCIENCES↗

TASTI-GRID: Overview of the State of Oregon’s Resilience and Reliability [Slides]

This report is intended to help your state identify the most effective investments to improve grid resilience and reliability, based on analysis of outage data, weather events, and the current state of the electric grid. The information presented is derived from the best available data. The discussions and recommendations included provide context and valuable insights into potential high returns on investment (ROI). Specifically, the report offers an overview of electric grid resilience in Oregon, covering outage information, reasons for outages, calculated "resilience scores" across the state, and recommendations for both immediate and long-term investments in grid infrastructure. The document provides a concise overview of the analytical capabilities of the TASTI-GRID team. By utilizing additional data and resources, it synthesizes insights from the platform to present a distinct perspective on investing in grid resilience throughout Oregon. This document is not intended to influence or direct state-level decisions related to investments in grid resilience and reliability. TASTI-GRID should not be used for real-time monitoring, supporting the ESF #12 emergency response functions, or predicting the restoration times for outages.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Architecture for Quantum-in-the Loop Real-Time Simulations for Designing Resilient Smart Grids

With the power grid growing more complex every day with the inclusion of new sensors and regulatory approvals that enable end-users and small local developers to participate in the grid, it is becoming challenging for conventional smart grid simulation, emulation, and testing technologies to keep up. In this work, we propose that quantum-encoded real-time simulations can be helpful under the new paradigm and operational circumstances to solve optimization problems for power grids. By leveraging the principles of quantum mechanics, the proposed quantum-in-loop (QIL) framework will enable better and faster optimization solutions based on real-world, real-time data streams, facilitating the real-time planning and operations of electrical grids that rely on millions of distributed sensors and controllers. Furthermore, QIL will allow researchers and engineers to assist utilities in designing, developing, and de-risking algorithms to optimize power grid operation and resilience by considering inputs from millions of grid-connected devices. QIL framework is being developed to have a self-limiting triage mechanism, which will help engineers and practitioners identify fundamental physical limits on quantum processors, revealing what quantum algorithms can and cannot do in utility-specific use cases and must continue to count on classical high-performance computing infrastructure.

digital real-time simulation↗

Modeling and Power-Hardware-in-the-Loop Validation of Synchronous Wind: An Inverterless Grid-Forming Wind Power Plant

Grid-forming (GFM) control of Type-3 and Type-4 wind turbine generators (WTGs) has attracted substantial attention in power systems research; however, the limited overcurrent capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. Synchronous wind, also known as a Type-5 WTG, offers a unique GFM solution to address grid integration and grid strength issues by keeping the grid largely synchronous at very high integration levels of renewable generation. A Type-5 WTG interfaces with the electric grid via a synchronous generator driven by a variable-speed hydraulic torque converter; hence, the wind rotor operates in variable-speed mode for maximum power generation, and the generator shaft remains synchronous to the grid. This paper develops and tests a high-fidelity model of a Type-5 WTG in a power-hardware-in-the-loop (PHIL) testing environment. The PHIL demonstration shows that a Type-5 WTG inherently behaves as a GFM unit and can obtain similar performance in terms of power responses, wind rotor dynamics, and efficiency compared to a Type-3 WTG in high-wind conditions. The developed model provides further insight into how Type-5 WTGs can benefit the smooth transition to power systems with high integration levels of inverter-based resources.

grid strength↗

Medium-Duty Delivery Truck Integrated Bidirectional Wireless Power Transfer System With Grid and Stationary Energy Storage System Connectivity

Electric vehicles (EVs) can provide power to the grid or buildings similar to distributed energy resources (DER) for energy balancing applications or optimizing the operation of the microgrids in harmony with the other DER assets. This article presents the operating modes of a bidirectional wireless power transfer (WPT) system designed for a medium-duty package delivery vehicle. The WPT system designed for this study can transfer 20 kW of power across 11 in of air gap using custom-designed double-D (DD) couplers with LCC–LCC tuning networks. The proposed system utilizes a 480-V three-phase grid connection, a plug-in hybrid delivery truck with bidirectional WPT, and a stationary energy storage system (SESS) that can be connected to the primary-side dc link. Due to the differences in primary and secondary dc bus voltages, and considering the voltage of the SESS, asymmetric voltage gains were used in the system. Sensitivity analyses of this system with respect to these voltage levels are presented. Five different operating modes of the grid, SESS, and the EV battery are investigated with experimental results. Control algorithms are described for grid-to-vehicle (G2V) and vehicle-to-grid (V2G) operating modes. A bidirectional WPT system is operated with a power factor of 0.99 on the grid side in every operating mode. The EV battery was charged with 20.3 kW with an overall efficiency of 93.02% in the G2V operating mode. Finally, in the V2G operating mode, the WPT system provided 12.82 kW of power back to the grid with an overall efficiency of 89.08%.

25 ENERGY STORAGE↗

Clean Grid Vision: A U.S. Perspective - Executive Summary

Clean Grid Vision: A U.S. Perspective aims to present a range of possible pathways for future grid development and call attention to some common trends. It focuses on the lessons learned through NREL’s studies of the U.S. power sector that have measured the impacts of high-penetration VRE and have tested strategies for enhancing grid flexibility and reliability. As such, this report is limited in its scope and does not attempt to review or summarize all grid integration literature. While it refers to relevant external literature to provide context when needed, this report is primarily a summary of the National Renewable Energy Laboratory’s (NREL’s) research in the past 5 years on five key topics: grid planning and operation, grid reliability at the distribution level, grid reliability at the transmission level, demand-side resources, and power markets—each corresponds to a chapter in this report. The main insights of the report are presented in this executive summary.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design of a Non-PLL Grid-Forming Inverter for Smooth Microgrid Transition Operation: Preprint

This paper develops a non-phase-locked loop (PLL) grid-connected inverter that can improve the microgrid’s transients during transition operation. By emulating the operation of a synchronous machine, the inverter generates its own voltage and frequency during startup, synchronizes and connects to the grid, then operates in reactive power mode (grid-feeding) with self-generated voltage and frequency, and switches to voltage-frequency mode to establish system voltage and frequency (grid-forming) when the microgrid disconnects from the main grid, and vice versa. To enable fast synchronization, active synchronization control is adopted both during inverter startup and microgrid reconnection operation. The simulation results show that the developed non-PLL grid-connected inverter works effectively to synchronize the inverter and microgrid to the grid and avoids a phase jump during microgrid transition operation. Thus, the microgrid’s transients are significantly improved with the proposed control technique.