Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Grid analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Evaluation of Greenland near surface air temperature datasets

Near-surface air temperature (SAT) over Greenland has important effects on mass balance of the ice sheet, but it is unclear which SAT datasets are reliable in the region. Here extensive in situ SAT measurements (~1400 station-years) are used to assess monthly mean SAT from seven global reanalysis datasets, five gridded SAT analyses, one satellite retrieval and three dynamically downscaled reanalyses. Strengths and weaknesses of these products are identified, and their biases are found to vary by season and glaciological regime. MERRA2 reanalysis overall performs best with mean absolute error less than 2°C in all months. Ice sheet-average annual mean SAT from different datasets are highly correlated in recent decades, but their 1901–2000 trends differ even in sign. Compared with the MERRA2 climatology combined with gridded SAT analysis anomalies, thirty-one earth system model historical runs from the CMIP5 archive reach ~5°C for the 1901–2000 average bias and have opposite trends for a number of sub-periods.

58 GEOSCIENCES↗

Physically Realistic Estimates of Electric Water Heater Demand Response Resource

Multiple grid integration studies have examined the value of demand response, including from water heaters, to bulk power systems. Common shortcomings of these studies include physically unrealistic assumptions. For example, studies often assume that all electric water heater load can be shed for up to an hour to provide capacity or contingency service, that all electric water heater load is shiftable, and that round-trip efficiencies for shifting service are 100%. Another issue is that simply summing up estimates of individual water heaters' flexibility bounds, an attractive idea for constructing the MW-scale resources necessary for direct inclusion in grid investment and operational models, can result in significant overestimates of actual resource, because, e.g., a water heater with the ability to reduce load may not be able sustain the reduction for as long as the aggregate model suggests is possible. This presentation demonstrates the impact of estimating the flexibility of electric water heaters with physically realistic models suitable for grid service analysis. Electric water heater flexibility representations are constructed based on ResStock simulations of New England. Specifically, we examine contingency resource (related to capacity, shed, and contingency reserve services) and energy shifting resource from electric resistance and heat pump water heaters. Different estimation methods are compared; and the surrogate models' event responses are validated against events directly simulated in EnergyPlus. We also demonstrate the impact of using electric water heaters for contingency reserves and energy shifting in detailed models of possible future ISO New England power systems.

building energy modeling↗

FORCE Development Status Update: Vertical Integration and Benchmarking of System Dynamics

Recent efforts to establish effective models for grid energy analysis, especially given the increase in variable renewable energy (VRE) sources and the economic challenges faced by traditional nuclear energy, have generated new technological considerations. One effort to improve the economic viability of nuclear power involves investigating integrated energy systems (IES) which include secondary energy systems that introduce flexibility and secondary market possibilities to existing and perceived future nuclear energy generation technologies. To analyze the technical and economic potential of IES, the Framework for Optimization of Resources and Economics (FORCE) tool suite was developed through a collaboration among national laboratories. Within the FORCE tool suite, the Holistic Energy Resource Optimization Network (HERON) provides algorithms for analyzing the long-term viability of potential IES technologies, while HYBRID provides algorithms and models to achieve high-resolution analysis of coupling physics over a short time period. Continued maturing of the FORCE tool suite requires further interconnections between the various tools in the suite in order to ensure consistent analysis. Analyses performed by applying HYBRID to transient process modeling should be easily harvestable as inputs to HERON analyses. The first item in this status update is a demonstration of an automated data pipeline for loading data from HYBRID into HERON analyses. Application of HYBRID results to HERON, as part of using the FORCE tool suite, relies on robust modeling assumptions for the various models included in HYBRID. The second result of this status update is the benchmarking and validation of cost and operational data, with a particular focus on natural gas energy generators. These generators are benchmarked with a focus on contrasting them with proposed thermal energy storage (TES) technologies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Accelerating Nuclear-Integrated Data Centers in the USA: SWOT Analysis, Power-Thermal Management Strategies, and Industrial-Scale Demonstration and Potential Deployment

Driven by the growth in digital services, cloud computing, AI, and manufacturing, data centers face rising energy demands that challenge traditional power sources and cooling efficiency. This study explores using nuclear power to meet these demands, focusing on accelerated reactor technology deployment and highlighting needs such as N+1/N+2 power supplies and integrated power-thermal management. A SWOT analysis addresses grid connectivity, reactors, and site selection, particularly DOE sites. Reactor technology demonstration and deployment could be accelerated by leveraging test facilities such as MARVEL, MAGNET, TED, FAS, DOME, LOTUS, ATR, Energy System Proving Grounds, and upcoming Energy Launch Pads, along with modeling and simulation tools such as RELAP5, MOOSE, VERA, RAVEN, and FORCE. The potential power and thermal management options, including various cooling technologies, waste-heat utilization, and an industrial-scale demonstration plan, aim to accelerate the integration of nuclear power and data centers in the USA, while emphasizing community and stakeholder engagement and synergistic efforts.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Enabling a Flexible Grid with Increased Penetration of DER: Techno-economic Analysis of Metal Hydride Thermochemical Energy Storage Integrated with Stirling Engine for Grid Energy Storage Applications

This report summarizes the results of a techno-economic assessment of the capital and operational expenses for 3 scenarios utilizing a TES/Stirling engine system which is charged by an electric heater to provide grid power and energy storage. While there are several integration possibilities and material choices that could be utilized in such systems, three difference scenarios were chosen for this assessment to reflect an anticipated deployment of the technology where each might require different TES system configurations. Additionally, an enhanced version of the HTMH is considered to demonstrate the expected impact on costs with further technology development. The predicted capital and operational LCOS for the system configurations range from $0.0198/kWhr e - $0.0734/kWhr e which compare positively to the LCOS for lithium ion battery storage ranging from $0.087/kWhr e – $0.329/kWhr e . The key drivers for cost improvements to the system are material property enhancements in the HTMH primarily related to reducing the costs associated with the HTMH vessel and heat exchangers. This analysis demonstrates the potential benefits and flexibility of integrating a Stirling engine with a metal hydride-based TES system and suggests that the MH TES technology, at its current level of development, provides a highly competitive alternative to lithium ion batteries for large scale grid energy storage applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Downscaling Aerosols and the Impact of Neglected Subgrid Processes on Direct Aerosol Radiative Forcing for a Representative Global Climate Model Grid Spacing

Recent improvements to many global climate models include detailed, prognostic aerosol calculations intended to better reproduce the observed climate. However, the trace gas and aerosol fields are treated at the grid-cell scale with no attempt to account for sub-grid impacts on the aerosol fields. This paper begins to quantify the error introduced by the neglected sub-grid variability for the shortwave aerosol radiative forcing for a representative climate model grid spacing of 75 km. An analysis of the value added in downscaling aerosol fields is also presented to give context to the WRF-Chem simulations used for the sub-grid analysis. We found that 1) the impact of neglected sub-grid variability on the aerosol radiative forcing is strongest in regions of complex topography and complicated flow patterns, and 2) scale-induced differences in emissions contribute strongly to the impact of neglected sub-grid processes on the aerosol radiative forcing. The two of these effects together, when simulated at 75 km vs. 3 km in WRF-Chem, result in an average daytime mean bias of over 30% error in top-of-atmosphere shortwave aerosol radiative forcing for a large percentage of central Mexico during the MILAGRO field campaign.

54 ENVIRONMENTAL SCIENCES↗

The Value of Energy Storage for Grid Applications

This analysis evaluates several operational benefits of electricity storage, including load-leveling, spinning contingency reserves, and regulation reserves. Storage devices were simulated in a utility system in the western United States, and the operational costs of generation was compared to the same system without the added storage. This operational value of storage was estimated for devices of various sizes, providing different services, and with several sensitivities to fuel price and other factors. Overall, the results followed previous analyses that demonstrate relatively low value for load-leveling but greater value for provision of reserve services. The value was estimated by taking the difference in operational costs between cases with and without energy storage and represents the operational cost savings from deploying storage by a traditional vertically integrated utility. The analysis also estimated the potential revenues derived from a merchant storage plant in a restructured market, based on marginal system prices. Due to suppression of on-/off-peak price differentials and incomplete capture of system benefits (such as the cost of power plant starts), the revenue obtained by storage in a market setting appears to be substantially less than the net benefit provided to the system. This demonstrates some of the additional challenges for storage deployed in restructured energy markets.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power System Event Detection Using the Energy Detector: A Performance Analysis

As the grid becomes smarter, the need to accurately detect, predict, and classify waveform phenomena is growing. When it comes to detecting high-frequency behaviors, i.e. transients, it is especially important to employ an event detection system that is able to accurately uncover these types of disturbances that would otherwise be lost with traditional hardware. In this paper, we first present the energy detector; a waveform event detection system that adaptively monitors a signal's energy and picks out high-frequency events that deviate from the nominal state. Secondly, we evaluate the performance of this detector against waveform data that have been corrupted by sensor irregularities. Using Oak Ridge National Laboratory's sensor testbed, we are able to show the results of the detector's performance against events that have been corrupted by three distinct sensor types, and examine how these results change with multiple trials. The results show excellent performance when detecting the beginning of an anomalous event with an average of less than 1% error.

Ekti, Ali Riza↗

Analysis on the Influence of an Energy Storage System and Its Impact to the Grid for a Wave Energy Converter: Preprint

This paper presents an analysis on the cost of and how a battery storage system can be used to further reduce the variation of power generated from the wave energy converter (WEC) due to the fluctuating nature of waves and its impact to the grid. The electrical power output from WEC-Sim simulations for the six sea states used in the Wave Energy Prize was analyzed to compute the peak power and power time history. The results were used to evaluate the battery storage capacity that is needed for a WEC system to provide reasonable power flow to the grid and estimate its cost based on the latest cost information for battery technologies published by the U.S. Energy Information Administration. Finally, a preliminary grid integration analysis was performed to demonstrate how WEC-generated power would contribute to a small island electricity system. As shown in the study, the instantaneous peak power is the primary cost driver for the battery storage and the power take-off system, and reducing the power fluctuations is essential for reducing the overall levelized cost of energy (LCOE). The power flow variation from WECs can be significantly reduced using battery storage without adding significant overall system costs, and the implementation of battery storage is essential for grid integration applications. There may also be additional opportunities to further investigate energy storage technologies that are specific to WEC applications to reduce these costs even further.

16 TIDAL AND WAVE POWER↗

A Dynamic Contingency Analysis Visualization Tool

We are developing a web-based visualization that shows the results of running a contingency analysis on a power grid system. Power grid analysists will be able to use this tool to visualize power event simulations and be better prepared for contingencies that may arise. The tool consists of a map, showing the power grid and its current state, and tables and charts showing the current status of various elements on the grid. The user can iterate over a number of cascading contingencies to visualize how the power grid will change under various scenarios.

Contingency analysis, power grid, smart grid, visu↗

Feasibility Study on Implementing a Staggered-Grid Finite Volume Method for System Analysis Code Development Under the MOOSE Framework

Here, this work summarizes a feasibility study on testing numerical algorithms that are suitable and efficient for advanced system analysis code development under the mutli-physics framework, MOOSE. The key to the test bed is the implementation of high-order one-dimensional staggered-grid finite volume method (SG-FVM), and its direct interaction with the linear/nonlinear solver, PETSc. The test bed utilized a more flexible code structure to enable the finite volume method implementation and direct interacting with the solver package, instead of using the natively supported finite element method by the framework. Using a suite of selected test problems with different problem sizes and levels of complexity, the implemented SG-FVM demonstrated superior performance improvement against a direct finite element method implementation through MOOSE. On two computer systems, the speedup was observed to be significant, with at least one order of magnitude of solving time reduction. For a complex reactor model, transient simulation was performed using the newly developed finite volume method code, the results of which agree very well with the reference results from the finite element method code. Overall, this study demonstrates a successful feasibility study on the proposed numerical algorithms and software structure to support advanced system analysis tool development.

MOOSE↗

Weather-Driven Resilience for Distribution Systems

With increasing billion dollar disasters due to weather events, it is of utmost priority for utility and grid operators to maintain and enhance the resilience of distribution grid. Traditionally, such analysis were conducted with reliability metrics alone. However, with increasing complexity of distribution grid and advancements in grid edge resources, evaluating grid resilience is challenging and involves multi-faceted analysis of the impact of weather events on the distribution grid. This presentation provides background, details, and future works in the field of weather-driven resilience for power distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Control system design and stability analysis for a three phase SiC-based Filter-less grid-connected PV inverter

In this paper, a control system of a filter-less grid-connected SiC inverter is designed. Stability analysis has been researched with a focus on grid disturbance rejection. The analysis shows that the conventional control method with instantaneous grid voltage feedforward (IGVF) will significantly limit the bandwidth or stability margin of a filter-less grid-connected inverter, thus make the inverter sensitive to grid disturbance. Two proposed grid voltage feedforward control methods, which require little additional computation resources, are presented to suppress the grid voltage disturbance. The design methods of control parameters are derived. The effects of the proposed feedforward methods are also compared with that of conventional IGVF. Lastly, the grid-connected experimental results of a three phase SiC based filter-less PV inverter are provided to verify and compare the proposed control methods.

30 DIRECT ENERGY CONVERSION↗

Provably-Stable Overload Ride-Through Control for Grid-Forming Inverters Using System-Wide Lyapunov Function Analysis

A key challenge associated with a grid-forming (GFM) inverter based resource (IBR) is its behavior during severe grid disturbances: since a GFM inverter regulates voltage in the fast timescale instead of current or power, it may experience a transient overload of current, power and/or energy during a severe grid disturbance. While many promising control strategies for overload ride-through have been proposed over the past two decades, transient stability of the system during and after the transition to an overload ride-through control mode remains difficult to guarantee. In this work, a novel overload ride-through control strategy is proposed for a system of grid-forming inverters that takes both self-protection and system-wide transient stability into account. A proposed system-level supervisory control uses slow communication to pre-emptively assign a set of local ride through control parameters to individual GFM IBR, including a current-limiting virtual reactance, that guarantees that synchronism is still preserved for any set of anticipated grid disturbances. At the core of the supervisory control lies a Lyapunov-function-based routine capable of establishing a strong, albeit conservative, transient stability guarantee for the system. Here, the proposed overload ride-through control strategy is validated via numerical integration of a reduced-order model, as well as through detailed electromagnetic transient (EMT) simulation.

30 DIRECT ENERGY CONVERSION↗