Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GSI”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Fast optimization and dose calculation in scanned ion beam therapy

Purpose: Particle therapy (PT) has advantages over photon irradiation on static tumors. An increased biological effectiveness and active target conformal dose shaping are strong arguments for PT. However, the sensitivity to changes of internal geometry complicates the use of PT for moving organs. In case of interfractionally moving objects adaptive radiotherapy (ART) concepts known from intensity modulated radiotherapy (IMRT) can be adopted for PT treatments. One ART strategy is to optimize a new treatment plan based on daily image data directly before a radiation fraction is delivered [treatment replanning (TRP)]. Optimizing treatment plans for PT using a scanned beam is a time consuming problem especially for particles other than protons where the biological effective dose has to be calculated. For the purpose of TRP, fast optimization and fast dose calculation have been implemented into the GSI in-house treatment planning system (TPS) TRiP98. Methods: This work reports about the outcome of a code analysis that resulted in optimization of the calculation processes as well as implementation of routines supporting parallel execution of the code. To benchmark the new features, the calculation time for therapy treatment planning has been studied. Results: Compared to the original version of the TPS, calculation times for treatment planning (optimization and dose calculation) have been improved by a factor of 10 with code optimization. The parallelization of the TPS resulted in a speedup factor of 12 and 5.5 for the original version and the code optimized version, respectively. Hence the total speedup of the new implementation of the authors' TPS yielded speedup factors up to 55. Conclusions: The improved TPS is capable of completing treatment planning for ion beam therapy of a prostate irradiation considering organs at risk in this has been overseen in the review process. Also see below 6 min.

60 APPLIED LIFE SCIENCES↗

SU-C-303-06: Treatment Planning Study for Non-Invasive Cardiac Arrhythmia Ablation with Scanned Carbon Ions in An Animal Model

Purpose: Scanned carbon ion beams might offer a non-invasive alternative treatment for cardiac arrhythmia, which are a major health-burden. We studied the feasibility of this procedure in an animal model. The underlying treatment planning and motion mitigation strategies will be presented. Methods: The study was carried out in 15 pigs, randomly distributed to 3 target groups: atrioventricular node (AVN, 8 animals with 25, 40, and 55 Gy target dose), left ventricular free-wall (LV, 4 animals with 40 Gy) and superior pulmonary vein (SPV, 3 animals with 40 Gy). Breathing motion was suppressed by repeated enforced breathholds at end exhale. Cardiac motion was mitigated by an inhomogeneous rescanning scheme with up to 15 rescans. The treatment planning was performed using the GSI in-house software TRiP4D on cardiac-gated 4DCTs, applying a range-considering ITV based on an extended CTV. For AVN and SPV isotropic 5 mm margins were applied to the CTV, while for the LV 2mm+2% range margins were used. The opposing fields for AVN and LV targets were optimized independently (SFUD), while SPV treatments were optimized as IMPT deliveries, including dose restrictions to the radiosensitive AVN. Results: Median value of D{sub 95} over all rescanning simulations was 99.1% (AVN), 98.0% (SPV) and 98.3% (LV) for the CTV and 94.7% (AVN) and 92.7% (SPV) for the PTV, respectively. The median D{sub 5}-D{sub 95} was improved with rescanning compared to unmitigated delivery from 13.3 to 6.5% (CTV) and from 23.4 to 11.6% (PTV). ICRP dose limits for aorta, trachea, esophagus and skin were respected. The maximal dose in the coronary arteries was limited to 30 Gy. Conclusion: We demonstrated the feasibility of a homogeneous dose delivery to different cardiac structures in a porcine model using a time-optimized inhomogeneous rescanning scheme. The presented treatment planning strategies were applied in a pig study with the analysis ongoing. Funding: This work was supported in part by the Helmholtz Association, the American Heart Association Midwest Affiliate Postdoctoral Fellowship Grant, the Mayo Clinic Foundation, and the Goldsmith Foundation.

60 APPLIED LIFE SCIENCES↗

WE-FG-207B-08: Dual-Energy CT Iodine Accuracy Across Vendors and Platforms

Purpose: Although a major benefit of dual-energy CT is its quantitative capabilities, it is critical to understand how results vary by scanner manufacturer and/or model before making clinical patient management decisions. Each manufacturer utilizes a specific dual-energy CT approach; cross-calibration may be required for facilities with more than one dual-energy CT scanner type. Methods: A solid dual-energy quality control phantom (Gammex, Inc.; Appleton, WI) representing a large body cross-section containing three Iodine inserts (2mg/ml, 5mg/ml, 15 mg/ml) was scanned on these CT systems: GE HD-750 (80/140kVp), prototype GE Revolution CT with GSI (80/140kVp), Siemens Flash (80/140kVp and 100/140kVp), and Philips IQon (120kVp and 140kVp). Iodine content was measured in units of concentration (mg/ml) from a single 5mm-thick central image. Three to five acquisitions were performed on each scanner platform in order to compute standard deviation. Scan acquisitions were approximately dose-matched (∼25mGy CTDIvol) and image parameters were as consistent as possible (thickness, kernel, no noise reduction applied). Results: Iodine measurement error ranges were −0.24-0.16 mg/ml for the 2mg/ml insert (−12.0 − 8.0%), −0.28–0.26 mg/ml for the 5mg/ml insert (−5.6 − 5.2%), and −1.16−0.99 mg/ml for the 15mg/ml insert (−7.7 − 6.6%). Standard deviations ranged from 0 to 0.19 mg/ml for the repeated acquisitions from each scanner. The average iodine measurement error and standard deviation across all systems and inserts was −0.21 ± 0.48 mg/ml (−1.5 ± 6.48%). The largest absolute measurement error was found in the 15mg/ml iodine insert. Conclusion: There was generally good agreement in Iodine quantification across 3 dual-energy CT manufacturers and 4 scanner models. This was unexpected given the widely different underlying dual-energy CT mechanisms employed. Future work will include additional scanner platforms, independent verification of the Iodine insert standard concentrations (especially the 15 mg/ml insert), and how much measurement variability can be clinically tolerated. This research has been supported by funds from Dr. William Murphy, Jr., the John S. Dunn, Sr. Distinguished Chair in Diagnostic Imaging at MD Anderson Cancer Center.

60 APPLIED LIFE SCIENCES↗

WE-FG-207B-10: Dual-Energy CT Monochromatic Image Consistency Across Vendors and Platforms

Purpose: Although dual-energy CT provides improved sensitivity of HU for certain tissue types at lower simulated energy levels, if these values vary by scanner type they may impact clinical patient management decisions. Each manufacturer has selected a specific dual-energy CT approach (or in one case, three different approaches); understanding HU variability among low monochromatic images may be required when more than one dual-energy CT scanner type is available for use. Methods: A large elliptical dualenergy quality control phantom (Gammex Inc.; Middleton, WI) containing several standard tissue type materials was scanned at least three times on each of the following systems: GE HD750, prototype GE Revolution CT with GSI, Siemens Flash, Siemens Edge, Siemens AS 128, and Philips IQon. Images were generated at 50, 70, and 140 keV. Soft tissue and Iodine HU were measured on a single central 5mm-thick image; NIST constants were used to calculate the ideal HU for each material. Scan acquisitions were approximately dose-matched (∼25mGy CTDIvol) and image parameters were held as consistent as possible (thickness, kernel, no noise reduction). Results: Measured soft tissue (29 HU at 120 kVp) varied from 28 HU to 44 HU at 50 keV (excluding one outlier), from 21 HU to 31 HU at 70 keV, and from 19 HU to 32 HU at 140 keV. Measured iodine (5mg/ml, 106 HU at 120 kVp) varied from 246 HU to 280 HU at 50 keV, from 123 HU to 129 HU at 70 keV, and from 22 HU to 32 HU at 140 keV. Conclusion: Measured HU in standard rods across 3 dual-energy CT manufacturers and 6 scanner models varied directly with monochromatic level, with the most variability was observed at 50 keV and least variability at 70keV. Future work will include additional scanner platforms and how measurement variability impacts radiologists. This research has been supported by funds from Dr. William Murphy, Jr., the John S. Dunn, Sr. Distinguished Chair in Diagnostic Imaging at MD Anderson Cancer Center.

60 APPLIED LIFE SCIENCES↗

Dilepton and strangeness production probed with HADES

With the High Acceptance Di-Electron Spectrometer (HADES) at GSI we have studied dilepton production in the few-GeV energy regime in various collisions systems, from elementary NN, over pA, up to the medium-heavy Ar + KCl system. We have thus confirmed the puzzling results of the former DLS Collaboration at the Bevalac. While we have traced the origin of the excess pair yield in CC collisions to elementary pp and pn processes, in our Ar + KCl data a contribution from the dense phase of the collision has been identified. Together with the e{sup +}e{sup -} pairs, we have also obtained in the Ar + KCl system at 1.76 A GeV a high-statistics data set on open and hidden strangeness, i.e. K{sup {+-}}, K{sub s}{sup 0}, {Lambda}, {phi}, and {Xi}{sup -}, allowing for a comprehensive discussion of strangeness production in this system.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calculated yield of isomer depletion due to NEEC for {sup 93m}Mo recoils

In the present work, quantitative calculations were carried out for production and depletion of the {sup 93m}Mo isomer in a relatively simple experiment using {sup 91}Zr beam ions. Such studies could be arranged at existing and operating accelerator facilities, e.g. at GSI or in JINR. The {sup 93m}Mo nuclei produced in a He gas target due to the {sup 4}He({sup 91}Zr, 2n) reaction will recoil into a gas stopper with a high velocity, being then depleted due to NEEC in highly-ionized species.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigation of the structure of light exotic nuclei by proton elastic scattering in inverse kinematics

In order to study the spatial structure of exotic nuclei, it was proposed at the Petersburg Nuclear Physics Institute (PNPI) to measure the differential cross section for small-angle proton elastic scattering in inverse kinematics. Several experiments in beams of 0.7-GeV/nucleon exotic nuclei were performed at the heavy-ion accelerator facility of GSI (Gesellschaft für Schwerionenforschung, Darmstadt, Germany) by using the IKAR ionization spectrometer developed at PNPI. The IKAR ionization chamber filled with hydrogen at a pressure of 10 bar served simultaneously as a target and as a recoil-proton detector, which measured the recoil-proton energy. The beam-particle scattering angle was also measured. The results obtained for the cross sections in question were analyzed on the basis of the Glauber-Sitenko theory using phenomenological nuclear-density distributions with two free parameters. Nuclear-matter distributions and root-mean-square radii were found for the nuclei under investigation. The size of the halo in the {sup 6}He, {sup 8}He, {sup 11}Li, and {sup 14}Be nuclei was determined among other things. Information about neutron distributions in nuclei was deduced by combining the data obtained here with the known values of the radii of proton distributions. A sizable neutron skin was revealed in the {sup 8}Li, {sup 9}Li, and {sup 12}Be nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Polarization effects in Drell-Yan processes

Effects of polarization of hadrons and constituent quarks in Drell-Yan processes are considered; they are one of the most efficient tools for investigation of the quark structure of hadrons. Special attention is paid to such important parton distribution functions as the transversity and T -odd Sivers and Boer—Mulders functions whose study is necessary for understanding the effects connected with the nonzero transverse component of the quark momentum. An original method for direct extraction of transversity and Boer—Mulders function in the proton from the data on Drell—Yan processes, in which a maximum of one hadron in the initial state is transversely polarized, is presented. This method possesses a number of important advantages. The method is applied both to Drell—Yan processes with a valence antiquark (antiproton-proton and pion-proton collisions) and with a sea antiquark (proton-proton, proton-deuteron, and deuteron-deuteron collisions). Theoretical estimates of asymmetries and cross sections for setups at RHIC (BNL, US), NICA (JINR, Russia), COMPASS (CERN, Switzerland), PAX (GSI, Germany), and J-PARC (Japan) are presented for evaluation of the measurability of transversity and T-odd distributions. These theoretical estimates are accompanied by calculations of statistical uncertainties for measured asymmetries using the new Monte Carlo generator of Drell—Yan events. The duality of Drell—Yan processes and those of production of J /Φ resonance is studied, and it may allow one to considerably reduce statistical uncertainties of parton distributions. Kinematical conditions, for which this duality can be observed, are evaluated.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spin filtering at COSY and perspectives for PAX

The high physics potential of experiments with stored polarized antiprotons led to the proposal of the PAX [1] experiment (Polarized Antiproton eXperiment) for the High Energy Storage Ring (HESR) of the new FAIR facility at GSI (Darmstadt/Germany). It is proposed to polarize a stored antiproton beam by means of spin filtering by a polarized hydrogen gas target. The feasibility of spin filtering with protons using a transversely polarized hydrogen gas target has been demonstrated in the FILTEX experiment [2] and recently confirmed at the COSY ring in Jülich. A spin filtering experiment using a longitudinally polarized hydrogen gas target is planned after the installation of a siberian snake in 2014. Further measurements including the investigation of pd-breakup reactions [3] and a test of the time reversal (TRIC) [4] are planned using the developed experimental setup. A proposal for a spin-filtering experiment with antiprotons at AD/CERN [5] has been submitted to the CERN SPS comitee to investigate the spin-dependence of the pbar-p and pbar-d interaction. This knowledge is necessary to properly design a dedicated Antiproton-Polarizer Ring.

43 PARTICLE ACCELERATORS↗

Synthesis of new transuranium isotopes in multinucleon transfer reactions using a velocity filter

Recently, we reported the observation of several new isotopes with proton numbers Z ≥ 92 in low-energy collisions of 48 Ca + 248 Cm . The peculiarity is that the nuclei were produced in multinucleon transfer reactions, a method which is presently discussed as a possible new way to enter so far unknown regions in the upper part of the Chart of Nuclides. For separation of the transfer products we used a velocity filter, the Separator for Heavy Ion Reaction Products SHIP at GSI. The resulting strong background suppression allowed us to detect nuclei with cross-sections down to the sub-nanobarn scale. Beside the new isotopes we identified about 100 further target-like transfer products and determined their cross-sections. In conclusion, the results together with previous measurements strongly indicate that multinucleon transfer reactions are a viable pathway to the production of new transuranium isotopes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Non-exponential and oscillatory decays in quantum mechanics

The quantum-mechanical theory of the decay of unstable states is revisited. We show that the decay is non-exponential both in the short-time and long-time limits using a more physical definition of the decay rate than the one usually used. We report results of numerical studies based on Winter's model that may elucidate qualitative features of exponential and non-exponential decay more generally. The main exponential stage is related to the formation of a radiating state that maintains the shape of its wave function with exponentially diminishing normalization. We discuss situations where the radioactive decay displays several exponents. The transient stages between different regimes are typically accompanied by interference of various contributions and resulting oscillations in the decay curve. The decay curve can be fully oscillatory in a two-flavor generalization of Winter's model with some values of the parameters. We consider the implications of that result for models of the oscillations reported by GSI.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison of Feschenko BSM and Fast Faraday Cup with Low Energy Ion Beams

A comparison between Fast Faraday Cup and Feschenko longitudinal bunch shape detectors was recently performed at HELIAC Advanced Demonstrator beamline at GSI. Feschenko bunch shape monitor (BSM) uses the time to space conversion by means of secondary electrons emitted from a wire correlated to a rf deflector, while the fast Faraday cup (FFC) measures the deposited charge in a cup geometry matched to 50 Ohm. The FFC design aims to minimize the bunch shape dilution due to field polarization and secondary electrons produced on irradiation. An He¹⁺ with 100 µA average current and 1.4 MeV/u kinetic energy is utilized for this comparison. A buncher upstream of the detectors was operated to focus the beam longitudinally. The results are discussed in this contribution.

43 PARTICLE ACCELERATORS↗

Electron Beam Dynamics Simulation for Electron Lenses

A test stand is under construction at CERN to study high perveance electron guns, electron beam dynamics, and electron beam diagnostics for electron lenses. It will be used to test electron guns for the Hollow Electron Lenses under consideration for beam halo control for High Luminosity LHC (CERN), and for the Space Charge Compensation at SIS18 (GSI) in the frame of the EU funded ARIES project. In order to prepare for this test stand, simulations will be presented and compared with experiments undertaken at the Fermilab (FNAL) electron lens test stand. These were conducted using a hollow electron gun, with the magnetic field configuration and beam current varied to study their effect. The impact of imperfections on the beam dynamics and overall quality of the electron beam will be discussed. A method for comparing experimental data with simulation is also presented to allow bench-marking of the computer models and simulation tools that will later be applied to the analysis of measurements performed at CERN.

43 PARTICLE ACCELERATORS↗

Report of Official Foreign Travel to Montreal, Canada

How can DOE, NNSA, and Y-12 best handle the integration of information from diverse sources, and what will best ensure that legacy data will survive changes in computing systems for the future? Although there is no simple answer, it is becoming increasingly clear throughout the information-management industry that a key component of both preservation and integration of information is the adoption of standardized data formats. The most notable standardized format is XML, to which almost all data is now migrating. XML is derived from SGML, as is HTML, the common language of the World Wide Web. XML is becoming increasingly important as part of the Y-12 data infrastructure. Y-12 is implementing a new generation of XML-based publishing systems. Y-12 already has been supporting projects at DOE Headquarters, such as the Guidance Streamlining Initiative (GSI) that will result in the storage of classification guidance in XML. Y-12 collects some test data in XML as the result of Electronic Data Capture (EDC), and XML data is also used in Engineering Releases. I am participating in a series of projects sponsored by the PRIDE initiative that include the capture of dimensional certification and other similar records in XML, the creation of XML formats for Electronic Data Capture, and the creation of Quality Evaluation Reports in XML. In support of DOE's use of SGML, XML, HTML, Topic Maps, and related standards, I served 1985-2007 as chairman of the international committee responsible for SGML and standards derived from it, ISO/IEC JTC1/SC34 (SC34) and its predecessor organizations; I continue to belong to the committee. During the August 2010 trip, I co-chaired the conference Balisage 2010.

99 GENERAL AND MISCELLANEOUS↗

International Shock-Wave Database Project: Report of the Requirements Workshop

We report on the requirements workshop for a new project, the International Shock-Wave database (ISWdb), which was held October 31 - November 2, 2011, at GSI, Darmstadt, Germany. Participants considered the idea of this database, its structure, technical requirements, content, and principles of operation. This report presents the consensus conclusions from the workshop, key discussion points, and the goals and plan for near-term and intermediate-term development of the ISWdb. The main points of consensus from the workshop were: (1) This international database is of interest and of practical use for the shock-wave and high pressure physics communities; (2) Intermediate state information and off-Hugoniot information is important and should be included in ISWdb; (3) Other relevant high pressure and auxiliary data should be included to the database, in the future; (4) Information on the ISWdb needs to be communicated, broadly, to the research community; and (5) Operating structure will consist of an Advisory Board, subject-matter expert Moderators to vet submitted data, and the database Project Team. This brief report is intended to inform the shock-wave research community and interested funding agencies about the project, as its success, ultimately, depends on both of these groups finding sufficient value in the database to use it, contribute to it, and support it.

99 GENERAL AND MISCELLANEOUS↗

Theoretical Treatment of Pressure Gradients in One-Dimensional, Inhomogeneous, Compressible Media

The purpose of the Generic Safety Issue (GSI) -191 research program sponsored by the U.S. Nuclear Regulatory Commission (NRC) was to determine if the formation, transport and accumulation of debris in a containment building following a loss-of-coolant accident (LOCA) could impede the operation of the emergency-core-cooling system (ECCS) in pressurized-water reactors (PWRs). The definition of “debris” was incrementally expanded over the course of the program to include not only thermal insulation damaged by direct jet impingement from a broken pipe, but also the latent dust and dirt that may be present in containment, and most recently, any adverse chemical products that might arise from the unique combination of spray additives, structural materials, and damaged insulation and coatings that will be present in the post-LOCA accident environment. The Integrated Chemical Effects Test (ICET) program was initiated by the NRC and conducted at the University of New Mexico (UNM) under the direction of Los Alamos National Laboratory (LANL) to study the possible formation of chemical products in prototypical containment conditions.

42 ENGINEERING↗

Continuous Evaluation of Fast Processes in Climate Models Using ARM Measurements

This five-year award supports the project “Continuous Evaluation of Fast Processes in Climate Models Using ARM Measurements (FASTER)”. The goal of this project is to produce accurate, consistent and comprehensive data sets for initializing both single column models (SCMs) and cloud resolving models (CRMs) using data assimilation. A multi-scale three-dimensional variational data assimilation scheme (MS-3DVAR) has been implemented. This MS-3DVAR system is built on top of WRF/GSI. The Community Gridpoint Statistical Interpolation (GSI) system is an operational data assimilation system at the National Centers for Environmental Prediction (NCEP) and has been implemented in the Weather Research and Forecast (WRF) model. This MS-3DVAR is further enhanced by the incorporation of a land surface 3DVAR scheme and a comprehensive aerosol 3DVAR scheme. The data assimilation implementation focuses in the ARM SGP region. ARM measurements are assimilated along with other available satellite and radar data. Reanalyses are then generated for a few selected period of time. This comprehensive data assimilation system has also been employed for other ARM-related applications.

54 ENVIRONMENTAL SCIENCES↗

FY21 NNSA-IAEC Science Area V, Environmental ISR, Waste Management and Subsurface Science (Final Report)

The FY21 NNSA NA-22 Final Report represents the progress achieved over the past year (FY21) by the research team for Topic Area 3, Waste Management & Subsurface Science (WM3), and Topic Area 7, Radiation and Thermal Effects on Bituminous Rocks (WM7). WM3 and WM7 are part of Science Area V (Subsurface Science and Waste Management) in the NNSA-IAEC Science and Technology Working Group. The project was initiated four years ago (2017) with an MOU agreement between the U.S. National Nuclear Security Administration (NNSA) and the Israel Atomic Energy Commission (IAEC) to evaluate the feasibility of geological subsurface disposal of radioactive waste in Israel. The core WM3 and WM7 teams are comprised of scientists and engineers from Los Alamos National Laboratory, the Geologic Survey of Israel (GSI), and the Nuclear Research Center - Negev (NRCN), with a close collaboration to the teams from Sandia National Laboratory (SNL) and Lawrence Livermore Laboratory (LLNL)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗