Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GRAPHITIZATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Microstructural Characterization of Al 4 C 3 in Aluminum-Graphite Composite Prepared by Electron-Beam Melting

We prepared graphite infused aluminum composites by electron-beam vacuum melting and electromagnetic stirring with 0% and 4wt% graphite addition. Bulk density of 2.69 g/cm 3 was measured for samples with 0% graphite addition (AlCv0) and 2.66 g/cm 3 for samples with 4 wt% graphite addition (AlCv4). Both are >99% of their theoretical values. X-ray diffraction indicated that AlCv0 is phase pure, while the AlCv4 sample is a composite consisting of aluminum, Al 4 C 3 , and graphite. Electron microscopy and energy dispersive X-ray spectroscopy revealed pockets of carbon rich phase of 10 to 50 μm in sizes dispersed in the Al matrix in AlCv4. Scanning transmission electron microscopy (STEM) showed that Al 4 C 3 crystallites of 1-2 μm sizes that are mostly located near the outer shell of the pockets of carbon rich phase and with undissolved graphite at the center. Thermal conductivity of 107.8 W/m·K was measured for the AlCv4 and 226.7 W/m·K for the AlCv0. Our work demonstrated the feasibility of producing pore-free high density graphite infused aluminum composite materials by electron-beam melting and electromagnetic stirring in vacuum.

36 MATERIALS SCIENCE↗

Engineering Nucleation Kinetics of Graphite Nodules in Inoculated Cast Iron for Reducing Porosity

Inoculation of cast iron with spherical graphite (SGI) controls nucleation kinetics of graphite nodules and is used for improving casting performance and eliminating solidification micro-porosity. In this study, thermodynamic simulations were used to design inoculants. Thermal and chemical stability of different potential heterogeneous nuclei formed in the melt above the liquidus temperature and in the mushy zone during solidification was predicted. Several inoculation treatments of SGI were performed in laboratory heats. An automated SEM/EDX analysis was applied to examine the graphite nodule size distribution and the family of the non-metallic inclusions in the experimental castings. The data were used to reconstruct a relative graphite nodule nucleation rate in the castings. It was shown that the graphite nodule nucleation kinetics in the castings were significantly different from those predicted by classical nucleation models. In inoculated SGI, the observed bi-modal distribution of graphite nodules was related to a continuous nucleation that occurred towards the end of solidification. The origin of the continuous nucleation and the possibility of engineering graphite nodules nucleation kinetics to control SGI casting soundness by inoculation are discussed.

36 MATERIALS SCIENCE↗

Fullerene-like defects in high-temperature neutron-irradiated nuclear graphite

Irradiation-induced defect evolution in graphite is particularly important for its application in graphite-moderated nuclear reactors. The evolution of defects directly influences macroscopically observed property changes in irradiated nuclear graphite which, in turn, can govern the lifetime of graphite components. This article reports novel defect structures and the irradiation response of microstructural features occurring in high-temperature irradiated nuclear graphite IG-110. High resolution transmission electron microscopy (HRTEM) was used to characterize specimens neutron-irradiated at a high temperature (≥ 800°C) at doses of 1.73 and 3.56 atomic displacements per atom (dpa). Concentric shelled and fullerene-like defects were found to result in swelling along the c-axis and contraction along the a/b-axis of crystallites. Furthermore, such defects are shown to occur within, and partially fill, Mrozowski cracks prior to turnaround dose. In addition, in situ TEM under similar irradiation conditions was used to capture the real-time dynamic evolution of defects, providing unambiguous analysis of the evolution of the graphite structures during irradiation. Here, the results suggest the mainstream theory for radiation damage in nuclear graphite (which assumes additional basal plane formation as the sole reason) to be an incorrect interpretation of defect evolution contributing to irradiation-induced property changes at higher temperatures.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Oxidation behaviors of matrix-grade graphite during water vapor ingress accidents for high temperature gas-cooled reactors

Water ingress into cores of high temperature gas-cooled reactors (HTGRs) can cause serious safety problems in graphitic components, especially for matrix graphite, which is more vulnerable than nuclear graphite. Here in this study, oxidation behaviors of a matrix-grade graphite, ARB-B1, were investigated under simulated water ingress accidental conditions. The oxidation tests were conducted in water vapor/helium mixed atmospheres at elevated temperatures up to 1200 °C. Oxidation rates and activation energy were evaluated by mass loss measurements. The activation energy was 121.5 kJ/mol in the considered temperature range, indicating only one oxidation regime-in-pore diffusion assisted by cracks. The cracks originated from the fabrication process, acting as penetration paths for the oxidant, played an important role in the oxidation behaviors. Ungraphitized binder oxidation occurred at all temperatures, while apparent oxidation of filler particles started from 1100 °C. Moreover, oxidation effects on compressive properties and hardness of the matrix graphite were discussed in terms of oxidized microstructures. This first detailed study on matrix graphite oxidation in water vapor provides important kinetics knowledge and microstructural and mechanical data for accidental scenarios of HTGRs as well as for development of new matrix graphite materials.

36 MATERIALS SCIENCE↗

Molten salt electrochemical upcycling of CO 2 to graphite for high performance battery anodes

The efficient transformation of CO 2 into a value-added material is a potential strategy to help mitigate climate effects caused by CO 2 emissions. One potential CO 2 conversion product is graphite which is an important and versatile material extensively used in many applications including as an anode for lithium-ion batteries (LIBs). Commercial graphite, however, is traditionally synthesized via the energy intensive Acheson process (>3000 °C) and the performance of such graphite can be limited under fast charging conditions which is important for vehicle electrification. We report the electrochemical transformation of CO 2 to highly crystalline nano-graphite with a controlled microstructure in a carbonate molten salt at 780 °C. The use of a nickel foam electrode and controlled electrochemical parameters during the molten salt conversion process yielded pure graphite at a lower temperature compared to the Acheson process. Moreover, when investigated as an anode material for LIBs, the CO 2 -converted graphite exhibited high reversible capacity, long cycle life, and excellent rate capability even under fast charging conditions. This process provides a way to potentially reduce carbon emissions through the utilization of waste CO 2 by converting it into value-added graphite suitable for fast charging, high-energy-density batteries for vehicle electrification.

25 ENERGY STORAGE↗

The transformation of diamond to graphite: Experiments reveal the presence of an intermediate linear carbon phase

Natural diamonds that have been partially replaced by graphite have been observed to occur in natural rocks. While the graphite-to-diamond phase transition has been extensively studied the opposite of this (diamond to graphite) remains poorly understood. We performed high-pressure and temperature hydrous and anhydrous experiments up to 1.0 GPa and 1300 °C using Amplex premium virgin synthetic diamonds (20–40 μm size) as the starting material mixed with Mg(OH) 2 as a source of H 2 O for the hydrous experiments. The experiments revealed that the diamond-to-graphite transformation at P = 1.0 GPa and T = 1300 °C was triggered by the presence of H 2 O and was accomplished through a three-stage process. Stage 1: diamond reacts with a supercritical H 2 O producing an intermediate 200–500 nm size “globular carbon” phase. This phase is a linear carbon chain; i.e. a polyyne or carbyne. Stage 2: the linear carbon chains are unstable and highly reactive, and they decompose by zigzagging and cross-linking to form sp 2 -hybridized structures. Stage 3: normal, disordered, and onion-like graphite is produced by the decomposition of the sp-hybridized carbon chains which are re-organized into sp 2 bonds. Our experiments show that there is no direct transformation from sp 3 C-bonds into sp 2 C-bonds. Our hydrous high-pressure and high-temperature experiments show that the diamond-to-graphite transformation requires an intermediate metastable phase of a linear hydrocarbon. This process also provides a simple mechanism for the substitution of other elements into the graphite structure (e.g. H, S, O).

36 MATERIALS SCIENCE↗

Enhancement of oxidation resistance of graphite foams by polymer derived-silicon carbide coating for concentrated solar power applications

Graphite foam with extremely high thermal conductivity has been investigated to enhance heat transfer of latent heat thermal energy storage (LHTES) systems. However, the use of graphite foam for elevated temperature applications (>600 °C) is limited due to poor oxidation resistance of graphite. In the present study, oxidation resistance of graphite foam coated with silicon carbide (SiC) was investigated. A pre-ceramic polymer derived coating (PDC) method was used to form a SiC coating on the graphite foams. Post coating deposition, the samples were analyzed by scanning electron microscopy and energy dispersive spectroscopy. The oxidation resistance of PDC-SiC coating was quantified by measuring the weight of the samples at several measuring points. The experiments were conducted under static argon atmosphere in a furnace. After the experiments, oxidation rates (%/hour) were calculated to predict the lifetime of the graphite foams. The experimental results showed that the PDC-SiC coating could prevent the oxidation of graphite foam under static argon atmosphere up to 900 °C.

36 MATERIALS SCIENCE↗

Highly durable graphene nanoplatelets supported Pt nanocatalysts for oxygen reduction

We report graphene nanoplatelets (GNP), which exhibit the advantages of both single-layer graphene and highly graphitic carbon, as a durable alternative support material for Pt nanoparticles for oxygen reduction in fuel cells. Pt nanoparticles are deposited on poly(diallyldimethylammonium chloride)(PDDA)-coated GNP, and characterized with transmission electron microscopy, X-ray diffraction, Raman spectra, and electrochemical tests. Pt/GNP exhibits greatly enhanced electrochemical durability (2-3 times that of Pt/CNT and commercial Etek Pt/C). These are attributed to the intrinsic high graphitization degree of GNP and the enhanced Pt-carbon interaction in Pt/GNP. If considering that GNP can be easily mass produced from graphite, GNP is a promising, low-cost, and durable electrocatalyst support for oxygen reduction in fuel cells.

carbon nanotubes↗

Multiscale characterization and comparison of historical and modern nuclear graphite grades

Beginning with Chicago Pile I, graphite has been used as a moderator material in nuclear power stations and is considered a potential material for use in future Generation IV advanced reactors. The microstructure of graphite is responsible for much of its mechanical and thermo-physical properties, and how it responds to irradiation. To understand graphite microstructure, it is necessary to understand its porosity at the macro- and micro-scales; and to understand its porosity, it is necessary to characterize the morphological connectivity of the void content and the two main phases of graphite: filler and binder. Here, using several microscopy and analytical techniques, a detailed examination of the heterogeneity, microstructure and pore structure of different graphite grades and their binder and filler phases is presented. Significant differences were found between coarser and finer nuclear grades. Coarse grades have a more diverse range of filler particles, pores and thermal cracks. Finer grades have a more well-defined pore size distribution, fewer variations of filler particles sizes and do not contain as many large thermal cracks. Fine grades tend to have a well-connected network of pores whereas coarser grades contain a larger content of closed porosity. The framework developed within this work can be applied and used to assess the various graphite grades that would down-select materials for specific use in graphite moderated reactor designs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Catalyzed oxidation of IG-110 nuclear graphite by simulated fission products Ag and Pd nanoparticles

To evaluate the stability of nuclear materials in high temperature gas reactors under air ingress conditions, catalytic oxidation of IG-110 graphite by two simulated fission products, metallic Pd and Ag, was studied in oxidative atmosphere and at temperatures up to 1000°C using an integrated furnace, mass spectroscopy and infrared spectroscopy system. Transmission electron microscopy and X-ray diffraction studies show that Pd and Ag nanoparticles were successfully introduced onto powdery IG-110 graphite through an impregnation and subsequent heat-treatment process. The combined mass spectroscopy and infrared spectroscopy methods allow simultaneous analysis of two gaseous products, CO and CO 2 , and separate measurements of activation energy for their formation reactions. It was found that the introduction of Pd or Ag to IG-110 graphite substantially catalyzed the oxidation of graphite, characteristic of decreased onset temperatures for the oxidation of graphite. Moreover, the catalytic effects by Pd and Ag are considerably different based on measured concentration ratios of CO 2 to CO as a function of oxidation temperatures. Ag makes the graphite oxidation commence at approximately 400°C with CO 2 being the dominant product. In contrast, Pd significantly increases the concentration ratio of CO 2 to CO at temperatures higher than approximately 690°C, although it decreases the onset temperature for the oxidation reaction to around 525°C. To understand the catalytic difference, the mechanism of the graphite oxidation was discussed based on the changes of surface oxygen species on Ag and Pd.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Insights into the Enhanced Reversibility of Graphite Anode Upon Fast Charging Through Li Reservoir

Increasing the charging rate and reducing the charging time for Li-ion batteries are crucial to realize the mainstream of electric vehicles. However, it is formidable to avoid the Li plating on graphite anode upon fast charging. Despite the tremendous progress in Li detection techniques, the fundamental mechanism of Li plating and its chemical/electrochemical responses upon cycling still remains elusive. Herein, we present a comprehensive electrochemical method to investigate the fast charging behavior of graphite electrode. A detailed analysis is directed toward understanding the changes in phase, composition, and morphology of the fast-charged graphite. By applying a resting process, we scrutinize the further reactions of the plated Li, which readily transforms into irreversible (dead) Li. We further develop a modified graphite electrode with a thin Ag coating as the Li reservoir. The plated Li can be "absorbed" by the Ag layer to form the Li-Ag solid solution that suppresses the formation of dead Li and provides structural stability, thus promoting the further lithiation of graphite and enhancing the reversibility. Here this work not only provides additional insights into the fast charging behavior of graphite electrode but also demonstrates a potential strategy to improve the fast charging performance of graphite anode.

25 ENERGY STORAGE↗

Self-terminating, heterogeneous solid–electrolyte interphase enables reversible Li–ether cointercalation in graphite anodes

Ether solvents are suitable for formulating solid-electrolyte interphase (SEI)-less ion-solvent cointercalation electrolytes in graphite for Na-ion and K-ion batteries. However, ether-based electrolytes have been historically perceived to cause exfoliation of graphite and cell failure in Li-ion batteries. In this study, we develop strategies to achieve reversible Li–solvent cointercalation in graphite through combining appropriate Li salts and ether solvents. Specifically, we design 1M LiBF 4 1,2-dimethoxyethane (G1), which enables natural graphite to deliver ~91% initial Coulombic efficiency and >88% capacity retention after 400 cycles. We captured the spatial distribution of LiF at various length scales and quantified its heterogeneity. The electrolyte shows self-terminated reactivity on graphite edge planes and results in a grainy, fluorinated pseudo-SEI. The molecular origin of the pseudo-SEI is elucidated by ab initio molecular dynamics (AIMD) simulations. The operando synchrotron analyses further demonstrate the reversible and monotonous phase transformation of cointercalated graphite. Our findings demonstrate the feasibility of Li cointercalation chemistry in graphite for extreme-condition batteries. The work also paves the foundation for understanding and modulating the interphase generated by ether electrolytes in a broad range of electrodes and batteries.

25 ENERGY STORAGE↗

Benchmark of Neutron Thermalization in Graphite Using a Pulsed Slowing-Down-Time Experiment

A benchmark has been developed using a pulsed slowing-down-time experiment to isolate the thermalization process in graphite. The experiment was conducted at the Oak Ridge Electron Linear Accelerator facility at Oak Ridge National Laboratory, and it measured the time spectrum of neutrons leaking from a graphite pile during slowing down and thermalization within graphite. Simulations of the benchmark experiment were performed using the MCNP6.1 Monte Carlo code and the ENDF/B-VII.1 and ENDF/B-VIII.0 cross-section databases. The benchmark provides a time spectrum (i.e., time-dependent counts in a detector) that allows for validation of the graphite thermal scattering libraries (TSLs). The impact on the simulations using a suite of graphite TSLs was compared with the experimental results. Given the density of nuclear graphite, the TSL corresponding to graphite with 30% porosity, as implemented in ENDF/B-VIII.0, was found to most accurately represent the measured time spectrum corresponding to the thermal energy range with an average deviation of ±1.7%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Modelling the graphite fracture mechanisms

In order to define a design criterion for graphite components, it is important to identify the physical phenomena responsible for the graphite fracture, to include them in a more effective modelling. In a first step, a large panel of experiments have been realised in order to build up an important database; results of tensile tests, 3 and 4 point bending tests on smooth and notched specimens have been analysed and have demonstrated an important geometry related effects on the behavior up to fracture. Then, first simulations with an elastic or an elastoplastic bilinear constitutive law have not made it possible to simulate the experimental fracture stress variations with the specimen geometry, the fracture mechanisms of the graphite being at the microstructural scale. That is the reason why a specific F.E. model of the graphite structure has been developed in which every graphite grain has been meshed independently, the crack initiation along the basal plane of the particles as well as the crack propagation and coalescence have been modelled too. This specific model has been used to test two different approaches for fracture initiation: a critical stress criterion and two criteria of fracture mechanic type. They are all based on crystallographic considerations as a global critical stress criterion gave unsatisfactory results. The criteria of fracture mechanic type being extremely unstable and unable to represent the graphite global behaviour up to the final collapse, the critical stress criterion has been preferred to predict the results of the large range of available experiments, on both smooth and notched specimens. In so doing, the experimental observations have been correctly simulated: the geometry related effects on the experimental fracture stress dispersion, the specimen volume effects on the macroscopic fracture stress and the crack propagation at a constant stress intensity factor. In addition, the parameters of the criterion have been related to experimental observations: the local crack initiation stress of 8 MPa corresponds to the non-linearity apparition on the global behavior observed experimentally and the the maximal critical stress defined for the particle of 30 MPa is equivalent to the fracture stress of notched specimens. This innovative combination of crack modelling and a local crystallographic critical stress criterion made it possible to understand that cleavage initiation and propagation in the graphite microstructure was driven by a mean critical stress criterion. (authors)

36 MATERIALS SCIENCE↗

SU-E-T-267: Development of the Compact Graphite Calorimetry System for the High Energy Photon Beam

Purpose: Graphite calorimeter systems are used for the absolute photon dosimetry. But many electronics are demanded in order to measure the tiny temperature changes. Minimizing the control system is needed to make a portable graphite calorimeter. Methods: A Domen-type graphite calorimetry system is constructing to measure the absorbed dose of the high energy photon beam. The graphite calorimeter divided into three parts, Core, Jacket, and Shield. In order to measure the temperature rising of the core due to the radiation accurately, the temperatures of the jacket and the shield should be controlled properly. A commercial temperature controller (Model 350, Lake Shore Cryogenics) was used to minimize the size of control system for making a portable graphite calorimetry system at the cost of the measurement uncertainty. The PID control of the jacket is conducted by the software (LabView) and Model 350 maintain the temperature of shield. Results: Our design value of the heat deposition power in the core is 0.04 mW for the dose rate of 3 Gy/min where the temperature sensitivity of the graphite is 1.4 mK/Gy. While the residuals of the Steinhart-hart equation fitting for the core thermistor were less than 0.1 mK, the temperature resolution of Model 350 is 1 mK. The temperature of the shield was kept within the 5 mK when the room temperature variation was about 0.5 K. Conclusion: The resolution of Model 350 for the temperature measurement and control is not good enough as the control system for the compact graphite calorimetry system. But The performance of Model 350 is good enough to maintain the temperature of the shield constantly. The Model 350 will be replaced by the AC resistance bridge (Model 372, Lake Shore Cryogenics) for the core temperature measurement and the jacket control.

07 ISOTOPE AND RADIATION SOURCES↗

SU-D-BRC-06: Experimental and Monte Carlo Studies of Fluence Corrections for Graphite Calorimetry in Proton Therapy

Purpose: For photon and electron beams, the standard device used to measure absorbed dose is a calorimeter. Standards laboratories are currently working on the establishment of graphite calorimeters as a primary standard for proton beams. To provide a practical method for graphite calorimetry, it is necessary to convert dose to graphite to dose to water, requiring knowledge of the water-to-graphite stopping-power ratio and the fluence correction factor. This study aims to present a novel method to determine fluence corrections experimentally, and to apply this methodology to low- and high-energy proton beams. Methods: Measurements were performed in 60 MeV and 180 MeV proton beams. Experimental information was obtained from depth-dose ionization chamber measurements performed in a water phantom. This was repeated with different thicknesses of graphite plates in front of the water phantom. One distinct advantage of this method is that only ionization chamber perturbation factors for water are required. Fluence corrections were also obtained through Monte Carlo simulations for comparison with the experiments. Results: The experimental observations made in this study confirm the Monte Carlo results. Overall, fluence corrections between water and graphite increased with depth, with a maximum correction of 1% for the low-energy beam and 4% for the high-energy beam. The results also showed that a fraction of the secondary particles generated in proton therapy beams do not have enough energy to cross the ionization chamber wall; thus, their contribution is not accounted for in the measured fluence corrections. This effect shows up as a discrepancy in fluence corrections of 1% and has been confirmed by simulations of the experimental setup. Conclusion: Fluence corrections derived by experiment do not account for low-energy secondary particles that are stopped in the ion chamber wall. This work will contribute to a practical graphite calorimetry technique for determining absolute dose to water in proton beams.

07 ISOTOPE AND RADIATION SOURCES↗

Thermoelectric Properties of Sb 2 Te 3 -Based Nanocomposites with Graphite

Antimony-telluride-based nanocomposite samples containing different weight fractions of graphite (Sb 2 Te 3 + x% graphite, where x = 0.0, 0.5, 1.0, and 2.5%) are synthesized and studied. The samples are produced by a solid-state reaction with the use of a ball mill. X-ray diffraction measurements show that the Sb 2 Te 3 phase is present in the nanocomposites. All of the diffraction peaks are identified as corresponding to the rhombohedral structure of symmetry R 3-bar m. No additional peaks related to graphite are observed because of its low content. Moreover, the X-ray data show the insolubility of graphite in Sb 2 Te 3 : the peaks related to Sb 2 Te 3 remain unchanged upon the addition of graphite. The thermal conductivity, thermoelectric power, and resistivity of the samples are studied in the temperature range 80 K ≤ T ≤ 320 K. The thermal conductivity k of the nanocomposite decreases several times compared to the thermal conductivity of single-crystal Sb 2 Te 3 and reaches k ≈ 0.95 W m -1 K -1 at x = 0.5%. The parameter k unsteadily depends on the content of graphite. The thermoelectric power of the nanocomposites with graphite at x = 1.0% is higher compared to that of nanostructured Sb 2 Te 3 .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

AGC-5 Graphite Pre-irradiation Data Analysis Report

This report documents all preirradiation examination material property measurement data for the graphite specimens which were to be used within the fifth Advanced Graphite Capsule (AGC-5) irradiation capsule. The AGC-5 capsule was to be the fifth in six planned irradiation capsules comprising the AGC test series that was designed to irradiate graphite specimens in a temperature range of 600 – 1100°C and medium dose levels to 7 dpa. This would provide quantitative data necessary for predicting the irradiation behavior and operating performance of new nuclear graphite grades for use within very high temperature reactor designs (VHTR). However, due to the lack of commercial interest in building a VHTR design within the USA, the graphite irradiation program was redirected by DOE Advanced Reactor Technology (ART) to re-irradiate the existing specimens from AGC-1 through AGC-4 in the remaining AGC capsules to achieve higher dose levels (15 dpa) at a lower irradiation temperature range (600-800°C). These new irradiation capsules have been designated as the High Dose Graphite (HDG) capsules. This new low temperature, high dose irradiation program favors the current high temperature reactor (HTR) design of interest to the US commercial nuclear community. This report summarizes the measurements from material property tests on the designated AGC-5 specimens. Similar to past AGC runs the specimens were categorized as major graphite grades (IG-110, NBG-17, NBG-18, PCEA and 2114), smaller experimental samples (thermal diffusivity sized specimens of major grades). It is anticipated that some AGC-5 specimens may be required for use within the new HDG-1 capsule. Any specimens from this pre-irradiation testing campaign will be identified in the future HDG-1 Pre-Irradiation Data Report. AGC-5 specimen testing was conducted at Idaho National Laboratory (INL) from December 2015 to February 2018.

(AGC)↗