Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GAS CHROMATOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Investigation of the hydrolytic and radiolytic degradation of HEH[EHP]

The extractant 2-ethylhexylphosphonic acid mono-2-ethylhexyl ester (HEH[EHP]) is a component used in both the Advanced TALSPEAK and ALSEP solvent extraction processes. The most likely compound formed via hydrolytic or radiolytic degradation of HEH[EHP] would be the phosphonic acid 2-ethylhexylphosphonic acid (H2EHP) that is formed by cleavage of the P-O-R bond. Thus far, attempts to detect H2EHP by gas chromatography or mass spectrometry have not been successful. The inability to detect this proposed degradation product in analytical samples is likely due to inadequate analysis techniques, lack of H2EHP production, further decomposition of H2EHP forming products not detectable by the employed analytical techniques, or a combination of all of the above scenarios. In order to address this problem, commercially available alkylphosphonic acids were acquired and used as surrogates for H2EHP in the gas chromatography and mass spectrometry analysis of samples. Once the ability to detect alkylphosphonic acid compounds was confirmed, these analytical techniques were used to confirm the production of H2EHP in samples of HEH[EHP] exposed to nitric acid and nitric acid plus gamma radiation. This report provides a brief summary of results and serves as documentation of the completion the level four milestone M4FT-16IN030102025 “Investigate the hydrolytic and radiolytic degradation of HEH[EHP]”.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Temperature-dependent changes in gas chromatographic separation metrics for trihexyl(tetradecyl)phosphonium-based ionic liquid stationary phases and comparison to conventional polysiloxane stationary phases

Here, to assess whether the trihexyl(tetradecyl)phosphonium chloride ([P 66614 + ][Cl - ]) ionic liquid (IL), employed as a gas chromatographic stationary phase, exhibits temperature-dependent phase transitions or structural heterogeneity, retention thermodynamics for probe molecules of varied chemical structure were investigated by gas chromatography (GC) over the temperature range of 25 to 64 °C using van’t Hoff analysis. All van’t Hoff plots for n-alkanes (C8–C12) and other probe analytes were linear, indicating the absence of detectable phase-transition behavior. The [P 66614 + ][Cl - ] IL was further compared with the [P 66614 + ] bis[(trifluoromethyl)sulfonyl]imide ([P 66614 + ][NTf 2 - ]) IL and commercial polysiloxane stationary phases in terms of temperature-dependent resolution behavior and chromatographic selectivity over the temperature range of 28–52 °C. The resolution factors of analytes in mixtures obtained using gas chromatography–mass spectrometry (GC–MS) and the summation of resolution values decreased smoothly with temperature on both IL stationary phases and on the dimethylphenylcyano-substituted polymeric stationary phase (OV-1701), whereas the poly(50% diphenyl/50% dimethyl siloxane) stationary phase (SPB-50) exhibited irregularities in its temperature-dependent summation of resolution profile, showing a distinct maximum in the temperature range of 34–40 °C. Selectivity values for the IL stationary phases were largely determined by the anion, with the [P 66614 + ][Cl - ] IL providing enhanced separation between polar and aromatic analytes, while the [P 66614 + ][NTf 2 - ] IL favored dispersive and π-π interactions that resulted in a reversal of elution order for some aliphatic–aromatic and alkyne-containing analyte pairs. Capillary columns prepared using different surface activation methods and coated with identical [P 66614 + ][Cl - ] IL stationary phase showed indistinguishable temperature-dependent trends in summation of resolution value and selectivity. An evaluation of analyte-specific selectivity provides insight into the characteristic separation behavior of the stationary phases and enables identification of analyte classes that are more efficiently separated on the [P 66614 + ]-based IL stationary phases compared to conventional stationary phase materials.

Chromatographic selectivity↗

Ch3MS-RF: a random forest model for chemical characterization and improved quantification of unidentified atmospheric organics detected by chromatography–mass spectrometry techniques

Abstract. The chemical composition of ambient organic aerosols plays a critical role in driving their climate and health-relevant properties and holds important clues to the sources and formation mechanisms of secondary aerosol material. In most ambient atmospheric environments, this composition remains incompletely characterized, with the number of identifiable species consistently outnumbered by those that have no mass spectral matches in the literature or the National Institute of Standards and Technology/National Institutes of Health/Environmental Protection Agency (NIST/NIH/EPA) mass spectral databases, making them nearly impossible to definitively identify. This creates significant challenges in utilizing the full analytical capabilities of techniques which separate and generate spectra for complex environmental samples. In this work, we develop the use of machine learning techniques to quantify and characterize novel, or unidentifiable, organic material. This work introduces Ch3MS-RF (Chemical Characterization by Chromatography–Mass Spectrometry Random Forest Modeling), an open-source, R-based software tool, for efficient machine-learning-enabled characterization of compounds separated in chromatography–mass spectrometry applications but not identifiable by comparison to mass spectral databases. A random forest model is trained and tested on a known 130 component representative external standard to predict the response factors of novel environmental organics based on position in volatility–polarity space and mass spectrum, enabling the reproducible, efficient, and optimized quantification of novel environmental species. Quantification accuracy on a reserved 20 % test set randomly split from the external standard compound list indicates that random forest modeling significantly outperforms the commonly used methods in both precision and accuracy, with a median response factor percent error of −2 %, for modeled response factors, compared to > 15 %, for typically used proxy assignment-based methods. Chemical properties modeling, evaluated on the same reserved 20 % test set and an extrapolation set of species identified in ambient organic aerosol samples collected in the Amazon rainforest, also demonstrate robust performance. Extrapolation set property prediction mean absolute errors for carbon number, oxygen to carbon ratio (O : C), average carbon oxidation state (OSc‾), and vapor pressure are 1.8, 0.15, 0.25, and 1.0 (log(atm)), respectively. Extrapolation set out-of-sample R2 for all properties modeled are above 0.75, with the exception of vapor pressure. While predictive performance for vapor pressure is less robust compared to the other chemical properties modeled, random-forest-based modeling was significantly more accurate than other commonly used methods of vapor pressure prediction, decreasing the mean vapor pressure prediction error to 0.24 (log(atm)) from 0.55 (log(atm)) (chromatography-based vapor pressure prediction) and 1.2 (log(atm)) (chemical formula-based vapor pressure prediction). The random forest model significantly advances an untargeted analysis of the full scope of chemical speciation yielded by two-dimensional gas chromatography (GCxGC-MS) techniques and can be applied to gas chromatography coupled with electron ionization mass spectrometry (GC-MS) as well. It enables the accurate estimation of key chemical properties commonly utilized in the atmospheric chemistry community, which may be used to more efficiently identify important tracers for further individual analysis and to characterize compound populations uniquely formed under specific ambient conditions.

54 ENVIRONMENTAL SCIENCES↗

Quantitative Characterization of Aqueous Byproducts from Hydrothermal Liquefaction of Municipal Wastes, Food Industry Wastes, and Biomass Grown on Waste

Hydrothermal liquefaction (HTL) is a viable thermochemical process for converting wet solid wastes into biocrude which can be hydroprocessed to liquid transportation fuel blendstocks and specialty chemicals. The aqueous byproduct from HTL contains significant amounts (20 to 50%) of the feed carbon, which must be used to enhance economic sustainability of the process on an industrial scale. In this study, aqueous fractions produced from HTL of industrial and municipal waste were characterized using a wide variety of analytical approaches. Organic chemical compounds present in these aqueous fractions were identified using two-dimensional gas chromatography equipped with time-of-flight mass spectrometry. Identified compounds include organic acids, nitrogen compounds, alcohols, aldehydes, and ketones. Conventional gas chromatography and liquid chromatography methods were employed to quantify the identified compounds. Inorganic species, in the aqueous stream of hydrothermal liquefaction of these aqueous byproducts, also were quantified using ion chromatography and inductively coupled plasma optical emission spectroscopy. The concentrations of organic chemical compounds and inorganic species are reported, and the significance of these results is discussed in detail.

Maddi, Balakrishna (ORCID:0000000153536026)↗

Experiments with the LECO Pegasus® Gas Chromatograph/ Time-of-Flight Mass Spectrometer Phase 2: 2D Fast GC Separations

Conventional analysis by gas chromatography/ quadrupole mass spectrometry (GC/MS) can be time-consuming (30 – 60 minutes) and prone to interferences. The use of fast gas chromatography coupled with time-of-flight mass spectrometry (GC/TOF-MS) offers the advantages of faster (~10 min) analysis times, improved GC resolution afforded by the use of narrower (0.1– 0.18 mm id) columns, and improved mass resolution and scan speed provided by the TOF-MS. In addition, GC/TOF-MS offers the promise of better instrument detection limits than quadrupole GC/MS, while still providing full mass spectral data. If the GC/TOF-MS can be operated to perform two-dimensional (2D) separations, the ability to resolve peaks of interest from interfering compounds is improved. In 2D chromatography, a second GC column with a different chemical phase than that of the first GC column is used to provide additional separation of analytes as they elute from the first column. Because the chemistry of the second GC column is different from the first, compounds that co-elute from the first column may be easily resolved after a separation on the second GC column (i.e., the peak capacity of the system is increased and the specificity of analyte detection is improved).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved Resolution of Hydrocarbon Structures and Constitutional Isomers in Complex Mixtures Using Gas Chromatography-Vacuum Ultraviolet-Mass Spectrometry

Understanding the composition of complex hydrocarbon mixtures is important for environmental studies in a variety of fields, but many prevalent compounds cannot be confidently identified using traditional gas chromatography/mass spectrometry (GC/MS) techniques. In this study, we use vacuum-ultraviolet (VUV) ionization to elucidate the structures of a traditionally “unresolved complex mixture” by separating components by GC retention time, t R , and mass-to-charge ratio, m/z, which are used to determine carbon number, N C , and the number of rings and double bonds, N DBE . Constitutional isomers are resolved on the basis of t R , enabling the most complete quantitative analysis to date of structural isomers in an environmentally relevant hydrocarbon mixture. Unknown compounds are classified in this work by carbon number, degree of saturation, presence of rings, and degree of branching, providing structural constraints. The capabilities of this analysis are explored using diesel fuel, in which constitutional isomer distribution patterns are shown to be reproducible between carbon numbers and follow predictable rules. Nearly half of the aliphatic hydrocarbon mass is shown to be branched, suggesting branching is more important in diesel fuel than previously shown. Lastly, the classification of unknown hydrocarbons and the resolution of constitutional isomers significantly improves resolution capabilities for any complex hydrocarbon mixture.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterizing PM 2.5 Emissions and Temporal Evolution of Organic Composition from Incense Burning in a California Residence

The chemical composition of incense-generated organic aerosol in residential indoor air has received limited attention in Western literature. In this study, we conducted incense burning experiments in a single-family California residence during vacancy. Here, we report the chemical composition of organic fine particulate matter (PM 2.5 ), associated emission factors (EFs), and gas-particle phase partitioning for indoor semivolatile organic compounds (SVOCs). Speciated organic PM 2.5 measurements were made using two-dimensional gas chromatography coupled with high-resolution time-of-flight mass spectrometry (GC×GC-HR-ToF-MS) and semivolatile thermal desorption aerosol gas chromatography (SV-TAG). Organic PM 2.5 EFs ranged from 7 to 31 mg g –1 for burned incense and were largely comprised of polar and oxygenated species, with high abundance of biomass-burning tracers such as levoglucosan. Differences in PM 2.5 EFs and chemical profiles were observed in relation to the type of incense burned. Nine indoor SVOCs considered to originate from sources other than incense combustion were enhanced during incense events. Time-resolved concentrations of these SVOCs correlated well with PM 2.5 mass (R 2 > 0.75), suggesting that low-volatility SVOCs such as bis(2-ethylhexyl)phthalate and butyl benzyl phthalate partitioned to incense-generated PM 2.5 . Both direct emissions and enhanced partitioning of low-volatility indoor SVOCs to incense-generated PM 2.5 can influence inhalation exposures during and after indoor incense use.

54 ENVIRONMENTAL SCIENCES↗

Amino Acids Profiles in Biological Media

An accurate analytical method was developed to determine amino acids in some biological specimens by GC/MS technique. Stable isotopes provide useful tools for a variety of studies, offering ideal internal standards in quantitative information. Isotopic dilution gas chromatography--mass spectrometry (ID-GC/MS) is the techniques used for quantitative analysis of compounds labeled with stable isotopes. A Trace DSQ Thermo Finnigan quadrupole mass spectrometer coupled with a Trace GC was used. Amino acids were separated on a Rtx-5 MS capillary column, 30 mx0.25 mm, 0.25 {mu}m film thickness, using a temperature program from 50 deg. C, 1 min, 6 deg. C/min at 100 deg. C, 4 deg. C/min at 200 deg. C, 20 deg. C/min at 300 deg. C, (3 min). The transfer line temperature was 250 deg. C, the injector temperature 200 deg. C and ion source temperature 250 deg. C; splitter: 10:1. Electron energy was 70 eV and emission current, 100 {mu}A. The amino acids were purified on a Dowex 50W-W8 exchange resin and were derivatized in a procedure following two steps to obtain trifluoroacetyl butyl esters. The identification of amino acids was obtained by using NIST library but also by using amino acid standards.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In situ identification of the Martian surface material and its interaction with the Martian atmosphere using DTA/GC

Little is known about the mineralogy of the martian surface material. Several techniques have been suggested as candidates for the in situ identification of the martian surface material. The most promising of these techniques include differential thermal analysis (DTA) coupled with gas chromatography (GC) and differential scanning calorimetry (DSC) coupled with either mass spectrometry (MS) or GC. Our studies showed that differential thermal analysis coupled with gas chromatography (DTA/GC) is a more appropriate analytical technique than DSC/MS or DSC/GC to identify the mineralogy of the martian surface material in situ. DTA/GC can be regarded as an advancement from pyrolytic GC analyses that were successfully flown on previous missions, but have supplied only limited mineralogical information.

Mancinelli, R. L.↗

Carbon isotopic analysis of atmospheric methane by isotope-ratio-monitoring gas chromatography-mass spectrometry

Less than 15 min are required for the determination of delta C(sub PDB)-13 with a precision of 0.2 ppt(1 sigma, single measurement) in 5-mL samples of air containing CH4 at natural levels (1.7 ppm). An analytical system including a sample-introduction unit incorporating a preparative gas chromatograph (GC) column for separation of CH4 from N2, O2, and Ar is described. The 15-min procedure includes time for operation of that system, high-resolution chromatographic separation of the CH4, on-line combustion and purification of the products, and isotopic calibration. Analyses of standards demonstrate that systematic errors are absent and that there is no dependence of observed values of delta on sample size. For samples containing 100 ppm or more CH4, preconcentration is not required and the analysis time is less than 5 min. The system utilizes a commercially available, high-sensitivity isotope-ratio mass spectrometer. For optimal conditions of smaple handling and combustion, performance of the system is within a factor of 2 of the shot-noise limit. The potential exists therefore for analysis of samples as small as 15 pmol CH4 with a standard deviation of less than 1 ppt.

Merritt, Dawn A.↗

Characterization of Kariya ( Hildegardia barteri (Mast.) Kosterm) Seed Oil Fatty Acid Methyl Ester Prepared from Basic Catalytic Transesterification

The rising global energy demand, alongside concerns regarding environmental deterioration due to the use of fossil fuels, has spurred extensive investigation into renewable energy alternatives. Biomass-derived biodiesel, especially from lesser-known oil sources, emerges as a promising option. This research focuses on analyzing the fatty acid methyl esters (FAMEs) derived from Kariya (Hildegardia barteri (Mast.) Kosterm) seed oil through basic catalytic transesterification using gas chromatography–flame ionization detector (GC–FID) analysis, assessing its potential as a biodiesel feedstock. Oil extraction from Kariya seeds was carried out using three solvents (n-hexane, ethanol, and a 1:1 blend of hexane and ethanol), followed by transesterification with methanol. Gas chromatography–mass spectrometry (GC–MS) and GC–FID analyses were utilized to identify and quantify FAMEs in the resulting biodiesel. The results revealed various FAMEs, including methyl myristate, methyl palmitate, methyl stearate, methyl oleate, methyl linoleate, and methyl linolenate. Significant differences in FAME composition were observed among the samples, with hexane–ethanol Kariya oil biodiesel (HE-KOB) showing the highest FAME content (76.1%). This combination of solvents exhibited synergistic effects on the composition of HE-KOB, suggesting potential optimization strategies for biodiesel production. Fourier transform infrared spectroscopy (FTIR) provided additional insights into the molecular composition of the biodiesel samples, confirming their biodiesel nature through the identified functional groups such as methyl, methylene, hydrocarbon, ester, aldehyde, and alkene. Thermogravimetric analysis (TGA) for thermal decomposition also gave an insight into FAME composition and its contribution to the degree of conversion of biodiesel to energy. These findings highlight the feasibility of utilizing Kariya seed oil as a biodiesel feedstock, emphasizing the importance of solvent selection and transesterification conditions in optimizing FAME yield and composition. This research contributes to the exploration of underutilized oil sources for sustainable biodiesel production, aligning with the global shift towards cleaner and renewable energy sources.

09 BIOMASS FUELS↗

A gas chromatographic air analyzer fabricated on a silicon wafer

A miniature gas analysis system has been built based on the principles of gas chromatography (GC). The major components are fabricated in silicon using photolithography and chemical etching techniques, which allows size reductions of nearly three orders of magnitude compared to conventional laboratory instruments. The chromatography system consists of a sample injection valve and a 1.5-m-long separating capillary column, which are fabricated on a substrate silicon wafer. The output thermal conductivity detector is separately batch fabricated and integrably mounted on the substrate wafer. The theory of gas chromatography has been used to optimize the performance of the sensor so that separations of gaseous hydrocarbon mixtures are performed in less than 10 s. The system is expected to find application in the areas of portable ambient air quality monitors, implanted biological experiments, and planetary probes.

Terry, S. C.↗

Search for life on Mars: Evaluation of techniques

An important question for exobiology is, did life evolve on Mars? To answer this question, experiments must be conducted on the martian surface. Given current mission constraints on mass, power, and volume, these experiments can only be performed using proposed analytical techniques such as: electron microscopy, X-ray fluorescence, X-ray diffraction, a-proton backscatter, g-ray spectrometry, differential thermal analysis, differential scanning calorimetry, pyrolysis gas chromatography, mass spectrometry, and specific element detectors. Using prepared test samples consisting of 1% organic matter (bovine serum albumin) in palagonite and a mixture of palagonite, clays, iron oxides, and evaporites, it was determined that a combination of X-ray diffraction and differential thermal analysis coupled with gas chromatography provides the best insight into the chemistry, mineralogy, and geological history of the samples.

Schwartz, D. E.↗

Signal analysis of NEMS sensors at the output of a chromatography column

This article introduces a joined Bayesian estimation of gas samples issued from a gas chromatography column (GC) coupled with a NEMS sensor based on Giddings Eyring microscopic molecular stochastic model. The posterior distribution is sampled using a Monte Carlo Markov Chain and Gibbs sampling. Parameters are estimated using the posterior mean. This estimation scheme is finally applied on simulated and real datasets using this molecular stochastic forward model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analytical methods for toxic gases from thermal degradation of polymers

Toxic gases evolved from the thermal oxidative degradation of synthetic or natural polymers in small laboratory chambers or in large scale fire tests are measured by several different analytical methods. Gas detector tubes are used for fast on-site detection of suspect toxic gases. The infrared spectroscopic method is an excellent qualitative and quantitative analysis for some toxic gases. Permanent gases such as carbon monoxide, carbon dioxide, methane and ethylene, can be quantitatively determined by gas chromatography. Highly toxic and corrosive gases such as nitrogen oxides, hydrogen cyanide, hydrogen fluoride, hydrogen chloride and sulfur dioxide should be passed into a scrubbing solution for subsequent analysis by either specific ion electrodes or spectrophotometric methods. Low-concentration toxic organic vapors can be concentrated in a cold trap and then analyzed by gas chromatography and mass spectrometry. The limitations of different methods are discussed.

Hsu, M.-T. S.↗

Evaluation of the application of some gas chromatographic methods for the determination of properties of synthetic fuels

The purpose of the investigation was to evaluate the applicability, to some synthetic fuels, of some gas chromatographic methods now under development for use with petroleum based fuels. Thirty-two jet and diesel fuel samples which were prepared from oil shale and coal syncrudes were examined. The boiling range distribution of each was determined by gas chromatography, and from that data distillation properties were calculated. The calculated results gave sufficient agreement with the measured values that the equations could be useable in their present form. Bulk fuel properties were calculated for the sixteen JP-5 and Diesel No. 2 type fuels. The results show that the equations would not give useable results. Capillary column gas chromatography was used to determine the n-alkane content of the eight JP-5 type samples and the results related to the observed freezing points. The results show that the concentrations of the long straight chain molecules in the fuels exert influence on the freezing point but are not the complete controlling factor.

Antoine, A. C.↗