Simplified Load-Following Control for a Fuel Cell System

A simplified load-following control scheme has been proposed for a fuel cell power system. The scheme could be used to control devices that are important parts of a fuel cell system but are sometimes characterized as parasitic because they consume some of the power generated by the fuel cells.

Vasquez, Arturo↗

Thermal System Sizing Comparison of a PEM and Solid Oxide Fuel Cell Systems on Mars

Power production is a key aspect to any Mars mission. One method for providing power throughout the day/night cycle, or to satisfy short-duration high-output power needs, is to utilize a regenerative fuel cell system for providing energy storage and nighttime or supplemental power. This study compares the total system mass for two types of fuel cell systems, proton exchange membrane (PEM) and solid oxide (SO), sized to provide 10 kW of electrical output power in the Mars environment. Two operating locations were examined; one near the equator at 4 °S latitude and one the higher northern latitude of 48°N. The systems were sized to operate throughout the year at these locations, where the radiator was sized for the worst-case warm condition and the insulation was sized for the worst-case cold condition. Using the selected system parameters, the results for both latitudes showed that the lightest system was the SO fuel cell with a PEM electrolyzer. This was mainly due to the higher operational temperature of the SO system enabled a significantly smaller radiator mass compared to that of the PEM fuel cell system. However, there was a significant difference in mass for the PEM system when operated near the equator as compared to the higher northern latitude. For the 10-kW output system this difference in mass was just under 100 kg.

Fuel Cells↗

A mathematical model of the maximum power density attainable in an alkaline hydrogen/oxygen fuel cell

A mathematical model of a hydrogen/oxygen alkaline fuel cell is presented that can be used to predict the polarization behavior under various power loads. The major limitations to achieving high power densities are indicated and methods to increase the maximum attainable power density are suggested. The alkaline fuel cell model describes the phenomena occurring in the solid, liquid, and gaseous phases of the anode, separator, and cathode regions based on porous electrode theory applied to three phases. Fundamental equations of chemical engineering that describe conservation of mass and charge, species transport, and kinetic phenomena are used to develop the model by treating all phases as a homogeneous continuum.

Kimble, Michael C.↗

Anhydrous Proton-Conducting Membranes for Fuel Cells

Polymeric electrolyte membranes that do not depend on water for conduction of protons are undergoing development for use in fuel cells. Prior polymeric electrolyte fuel-cell membranes (e.g., those that contain perfluorosulfonic acid) depend on water and must be limited to operation below a temperature of 125 C because they retain water poorly at higher temperatures. In contrast, the present developmental anhydrous membranes are expected to function well at temperatures up to 200 C. The developmental membranes exploit a hopping-and-reorganization proton- conduction process that can occur in the solid state in organic amine salts and is similar to a proton-conduction process in a liquid. This process was studied during the 1970s, but until now, there has been no report of exploiting organic amine salts for proton conduction in fuel cells.

Narayanan, Sekharipuram↗

Analysis of a fuel cell on-site integrated energy system for a residential complex

The energy use and costs of the on-site integrated energy system (OS/IES) which provides electric power from an on-site power plant and recovers heat that would normally be rejected to the environment is compared to a conventional system purchasing electricity from a utility and a phosphoric acid fuel cell powered system. The analysis showed that for a 500-unit apartment complex a fuel OS/IES would be about 10% more energy conservative in terms of total coal consumption than a diesel OS/IES system or a conventional system. The fuel cell OS/IES capital costs could be 30 to 55% greater than the diesel OS/IES capital costs for the same life cycle costs. The life cycle cost of a fuel cell OS/IES would be lower than that for a conventional system as long as the cost of electricity is greater than $0.05 to $0.065/kWh. An analysis of several parametric combinations of fuel cell power plant and state-of-art energy recovery systems and annual fuel requirement calculations for four locations were made. It was shown that OS/IES component choices are a major factor in fuel consumption, with the least efficient system using 25% more fuel than the most efficient. Central air conditioning and heat pumps result in minimum fuel consumption while individual air conditioning units increase it, and in general the fuel cell of highest electrical efficiency has the lowest fuel consumption.

Simons, S. N.↗

Develop and test fuel cell powered on-site integrated total energy systems: Phase 3: Full-scale power plant development

The development of a commercially viable and cost-effective phospheric acid fuel cell powered on-site integrated energy system (OS/IES) is described. The fuel cell offers energy efficients in the range of 35-40% of the higher heating value of available fuels in the form of electrical energy. In addition, by utilizing the thermal energy generated for heating, ventilating and air-conditioning (HVAC), a fuel cell OS/IES could provide total energy efficiencies in the neighborhood of 80%. Also, the Engelhard fuel cell OS/IES offers the important incentive of replacing imported oil with domestically produced methanol, including coal-derived methanol.

Source record↗

Fuel cell on-site integrated energy system parametric analysis of a residential complex

A parametric energy-use analysis was performed for a large apartment complex served by a fuel cell on-site integrated energy system (OS/IES). The variables parameterized include operating characteristics for four phosphoric acid fuel cells, eight OS/IES energy recovery systems, and four climatic locations. The annual fuel consumption for selected parametric combinations are presented and a breakeven economic analysis is presented for one parametric combination. The results show fuel cell electrical efficiency and system component choice have the greatest effect on annual fuel consumption; fuel cell thermal efficiency and geographic location have less of an effect.

Simons, S. N.↗

Effect of Reactant Purity on Proton Exchange Membrane Fuel Cell Performance

NASA has set a goal to return to the Moon and to establish a sustained lunar presence. Many applicable lander and upperstage vehicle concepts utilize cryogenic H2 and O2 propellants. This propellant selection enables appealing potential mission concepts wherein electricity is generated by operating a fuel cell on residual H2 and O2 propellants. This concept depends on the capability of the fuel cell to utilize dry, propellant-grade reactants with concentrations of up to 30 percent He present. This study consists of the evaluation of a 12-cell non-flow-through proton exchange membrane fuel cell stack of 50 sq. cm active area with passive water removal. This stack was supplied with three levels of reactant purity: >99.999, 99.1, and 70 mol%, with the remainder made up of He. The reactant humidity and flow-through rate were also assessed as performance factors, and the fuel stack repeatedly supported a load profile with current densities up to 500 mA/sq. cm (25 A). The fuel cell performed consistently over the course of testing, with cell voltages decreasing approximately 50 mV at the maximum current density when supplied with reactants with 30 percent He present.

electrochemistry↗

Advanced Fuel Cell System Thermal Management for NASA Exploration Missions

The NASA Glenn Research Center is developing advanced passive thermal management technology to reduce the mass and improve the reliability of space fuel cell systems for the NASA exploration program. An analysis of a state-of-the-art fuel cell cooling systems was done to benchmark the portion of a fuel cell system s mass that is dedicated to thermal management. Additional analysis was done to determine the key performance targets of the advanced passive thermal management technology that would substantially reduce fuel cell system mass.

Burke, Kenneth A.↗

Teledyne Energy Systems, Inc., Proton Exchange Member (PEM) Fuel Cell Engineering Model Powerplant. Test Report: Initial Benchmark Tests in the Original Orientation

Proton Exchange Membrane (PEM) fuel cell technology is the leading candidate to replace the alkaline fuel cell technology, currently used on the Shuttle, for future space missions. During a 5-yr development program, a PEM fuel cell powerplant was developed. This report details the initial performance evaluation test results of the powerplant.

Loyselle, Patricia↗

High energy efficiency and high power density proton exchange membrane fuel cells: Electrode kinetics and mass transport

The development of proton exchange membrane (PEM) fuel cell power plants with high energy efficiencies and high power densities is gaining momentum because of the vital need of such high levels of performance for extraterrestrial (space, underwater) and terrestrial (power source for electric vehicles) applications. Since 1987, considerable progress has been made in achieving energy efficiencies of about 60 percent at a current density of 200 mA/sq cm and high power densities (greater than 1 W/sq cm) in PEM fuel cells with high (4 mg/sq cm) or low (0.4 mg/sq cm) platinum loadings in electrodes. The following areas are discussed: (1) methods to obtain these high levels of performance with low Pt loading electrodes - by proton conductor impregnation into electrodes, localization of Pt near front surface; (2) a novel microelectrode technique which yields electrode kinetic parameters for oxygen reduction and mass transport parameters; (3) demonstration of lack of water transport from anode to cathode; (4) modeling analysis of PEM fuel cell for comparison with experimental results and predicting further improvements in performance; and (5) recommendations of needed research and development for achieving the above goals.

Supramaniam Srinivasan↗

Proton Exchange Membrane Fuel Cell Engineering Model Powerplant. Test Report: Benchmark Tests in Three Spatial Orientations

Proton exchange membrane (PEM) fuel cell technology is the leading candidate to replace the aging alkaline fuel cell technology, currently used on the Shuttle, for future space missions. This test effort marks the final phase of a 5-yr development program that began under the Second Generation Reusable Launch Vehicle (RLV) Program, transitioned into the Next Generation Launch Technologies (NGLT) Program, and continued under Constellation Systems in the Exploration Technology Development Program. Initially, the engineering model (EM) powerplant was evaluated with respect to its performance as compared to acceptance tests carried out at the manufacturer. This was to determine the sensitivity of the powerplant performance to changes in test environment. In addition, a series of tests were performed with the powerplant in the original standard orientation. This report details the continuing EM benchmark test results in three spatial orientations as well as extended duration testing in the mission profile test. The results from these tests verify the applicability of PEM fuel cells for future NASA missions. The specifics of these different tests are described in the following sections.

Loyselle, Patricia↗

Vapor diffusion electrode improves fuel cell operation

Vapor diffusion type fuel cell electrode presents a nonwetting barrier to the liquid feedstocks so they may contact the electrolyte only in the vapor state. Thus, it effects feedstock mixing with the electrolyte at the electrolyte/catalyst interface but prevents feedstock decomposition and catalyst poisoning from liquid mingling.

Smith, J. O.↗

Fuel cells- Their electrochemistry

Book on fuel cells electrochemistry covering direct energy conversion methods, electrode kinetics, electrocatalysis, organic substances, electrochemical combustion, research techniques, etc

Bockris, J. OM.↗

Fuel cell with ionization membrane

A fuel cell is disclosed comprising an ionization membrane having at least one area through which gas is passed, and which ionizes the gas passing therethrough, and a cathode for receiving the ions generated by the ionization membrane. The ionization membrane may include one or more openings in the membrane with electrodes that are located closer than a mean free path of molecules within the gas to be ionized. Methods of manufacture are also provided.

Hartley, Frank T.↗