Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fluorescence Detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Remote detection of OH

This is a remote measurement technique utilizing a XeCl excimer laser tuned to the Q sub 21 1 rotational transition of the 0-0, A-X band at 307.847 nm. A wavemeter is under development to monitor, on a pulse-to-pulse basis, both the laser lineshape and absolute wavelength. Fluorescence is detected with a multiple Fabry-Perot type filter with a spectral resolution on the order of 0.001 nm. This is tuned to the overlapping Q sub 2 2, Q sub 12 2, Q sub 2 3, and Q sub 12 3 rotational transitions at 308.986 nm. The fringe pattern from this filter is imaged using a discrete, multi-anode detector which has a photon gain of 10 to the 8th power. This permits the simultaneous monitoring of OH fluorescence, N2 and/or O2 rotational Raman scattering and broadband background levels. The use of three etalons in series provides sufficient rejection, approx. greater than 10 to the 10th power, against the laser radiation only 1.2 nm away.

Mcdermid, I. Stuart↗

Evaluation of an event-driven 3FI ASIC for spectroscopic X-ray detection with synchrotron radiation

The novel design and evaluation on the NSLS-II beamline of the 3FI application-specific integrated circuit (ASIC) bump-bonded to a simple, planar, 2D segmented silicon sensor are presented. The ASIC was developed for full-field fluorescence spectral X-ray imaging (3FI). It is a small-scale prototype that features a square array of 32 × 32 pixels, and the size of the pixels is 100 µm × 100 µm. The ASIC was implemented in a 65 nm CMOS integrated circuit fabrication process. Each pixel incorporates a charge-sensitive amplifier, a shaping filter, a discriminator, a peak detector and a sample-and-hold circuit, allowing detection of events and storage of signal amplitudes. The system operates in a frameless event-driven readout mode, outputting analog values for threshold-triggered events, allowing high-speed multi-element X-ray fluorescence data acquisition. The 3FI ASIC achieves per-channel spectrometric performance at a power consumption of only 200 µW per pixel, with nearly all dissipation confined to the analog front-end. An energy resolution is measured at the level of 308 eV full width at half-maximum (FWHM) at 8.04 keV (Cu Kα), and 138 eV FWHM at 3.69 keV (Ca Kα). This per-pixel capability makes the prototype suitable for in situ trace element microanalysis in biological and environmental studies. Moreover, the frameless architecture of the detector is designed to address limitations of conventional X-ray fluorescence microscopy, which typically requires mechanical scanning, by enabling continuous high-throughput data acquisition in future full-field implementations.

47 OTHER INSTRUMENTATION↗

Development of a Sodium LIDAR for Spaceborne Missions

We are currently developing laser and electro-optic technologies to remotely measure Sodium (Na) by adapting existing lidar technology with space flight heritage. The developed instrumentation will serve as the core for the planning of a Heliophysics mission targeted to study the composition and dynamics of Earths mesosphere based on a spaceborne lidar that will measure the mesospheric Na layer. There is a pressing need in the Ionosphere Thermosphere - Mesosphere (ITM) community for high-resolution measurements that can characterize small-scale dynamics (i.e. Gravity Waves with wavelengths smaller than a few hundred km) and their effects in the Mesosphere-Lower-Termosphere (MLT) on a global basis. This is compelling because they are believed to be the dominant contributors to momentum transport and deposition in the MLT, which largely drive the global circulation and thermal structure and interactions with the tides and planetary waves in this region. We are developing a spaceborne remote sensing technique that will enable acquisition of global Na density, temperature and wind measurements in the MLT with the spatial and temporal resolution required to resolve issues associated with the structure, chemistry, dynamics, and energetics of this regionA nadir-pointing spaceborne Na Doppler resonance fluorescence LIDAR on board of the ISS will essentially make high-resolution, in time and space, Na density, temperature and vertical wind measurements, from 75-115 km (MLT region). Our instrument concept consisted of a high-energy laser transmitter at 589 nm and highly sensitive photon counting detector that allows for range-resolved atmospheric-sodium-temperature profiles. The atmospheric temperature is deduced from the linewidth of the resonant fluorescence from the atomic sodium vapor D2 line as measured by our tunable laser. We are currently developing a high power energy laser that allows for some day time sodium lidar observations with the help of a narrow bandpass filter based on etalon or atomic sodium Faraday filter with 5 to 10 pm optical bandwidth. The current baseline detector for the lidar instrument is a 16-channel Photomultiplier Tube with receiver electronics that has been space-qualified for the ICESat-2ATLAS mission. Our technique uses the 16-channels as a photon-number-resolving single detector to provide the required full-spectroscopic sodium lineshape waveform for recovering Mesospheric temperature profiles. In this paper, we will describe our instrument concept for a future Heliophysics space mission based on board of the International Space Station (ISS).

lidar↗

Novel xenon calibration scheme for two-photon absorption laser induced fluorescence of hydrogen

Two photon absorption laser induced fluorescence (TALIF) measurements of neutral hydrogen and its isotopes are typically calibrated by performing TALIF measurements on krypton with the same diagnostic system and using the known ratio of the absorption cross sections [K. Niemi et al., J. Phys. D 34, 2330 (2001)]. Here we present the measurements of a new calibration method based on a ground state xenon scheme for which the fluorescent emission wavelength is nearly identical to that of hydrogen, thereby eliminating chromatic effects in the collection optics and simplifying detector calibration. We determine that the ratio of the TALIF cross sections of xenon and hydrogen is 0.024 ± 0.001.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct measurement of 235 U in spent fuel rods with Gamma-ray mirrors

We report here that direct measurement of plutonium and uranium X-rays and gamma-rays is a highly desirable nondestructive analysis method for the use in reprocessing fuel environments. The high background and intense radiation from spent fuel make direct measurements difficult to implement since the relatively low activity of uranium and plutonium is masked by the high activity from fission products. To overcome this problem, we make use of a grazing incidence optic to selectively reflect K α and K β fluorescence of Special Nuclear Materials (SNM) into a high-purity position-sensitive germanium detector and obtain their relative ratios.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Synchrotron radiation-based Mössbauer spectra of {sup 174}Yb measured with internal conversion electrons

A detection system for synchrotron-radiation (SR)-based Mössbauer spectroscopy was developed to enhance the nuclear resonant scattering counting rate and thus increase the available nuclides. In the system, a windowless avalanche photodiode (APD) detector was combined with a vacuum cryostat to detect the internal conversion (IC) electrons and fluorescent X-rays accompanied by nuclear de-excitation. As a feasibility study, the SR-based Mössbauer spectrum using the 76.5 keV level of {sup 174}Yb was observed without {sup 174}Yb enrichment of the samples. The counting rate was five times higher than that of our previous system, and the spectrum was obtained within 10 h. This result shows that nuclear resonance events can be more efficiently detected by counting IC electrons for nuclides with high IC coefficients. Furthermore, the windowless detection system enables us to place the sample closer to the APD elements and is advantageous for nuclear resonant inelastic scattering measurements. Therefore, this detection system can not only increase the number of nuclides accessible in SR-based Mössbauer spectroscopy but also allows the nuclear resonant inelastic scattering measurements of small single crystals or enzymes with dilute probe nuclides that are difficult to measure with the previous detection system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Secured Optical Communications Using Quantum Entangled Two-Photon Transparency Modulation

A system and method is disclosed wherein optical signals are coded in a transmitter by tuning or modulating the interbeam delay time (which modulates the fourth-order coherence) between pairs of entangled photons. The photon pairs are either absorbed or not absorbed (transparent) by an atomic or molecular fluorescer in a receiver, depending on the inter-beam delay that is introduced in the entangled photon pairs. Upon the absorption, corresponding fluorescent optical emissions follow at a certain wavelength, which are then detected by a photon detector. The advantage of the disclosed system is that it eliminates a need of a coincidence counter to realize the entanglement-based secure optical communications because the absorber acts as a coincidence counter for entangled photon pairs.

Kojima, Jun↗

Synchrotron-based Scattered Radiation from Phantom Materials used in X-ray CT

Synchrotron-based scattered radiation form low-contrast phantom materials prepared from polyethylene, polystyrene, nylon, and Plexiglas is used as test objects in X-ray CT was examined with 8, 10 and 12 keV X-rays. These phantom materials of medical interest will contains varying proportions of low atomic number elements. The assessment will allowed us to estimate the fluorescence to total scattered radiation. Detected the fluorescence spectra and the associated scattered radiation from calcium hydroxyapatite phantom with 8, 10 and 12 keV synchrotron X-rays. Samples with Bonefil (60% and 70% of calcium hydroxyapatite) and Bone cream (35-45% of calcium hydroxyapatite), were used. Utilized the X-ray micro-spectroscopy beamline facility, X27A, available at NSLS, BNL, USA. The primary beam with a spot size of the order of {approx}10 {micro}m, has been used for focusing. With this spatial resolution and high flux throuput, the synchrotron-based scattered radiation from the phantom materials were measured using a liquid-nitrogen-cooled 13-element energy-dispersive high-purity germanium detector.

58 GEOSCIENCES↗

Photon Activation Analysis--An Analytical Application Of High-Energy Electron Accelerators

Photon activation analysis (PAA) was introduced about contemporarily with the other activation analysis methods (neutron, NAA, and charged particle activation, CPAA). Nonetheless, for different reasons, PAA has been applied less frequently than the other techniques mentioned. The incident photon energy should exceed about 12 MeV (except in some special rare applications) so as to obtain appreciably high activity yields of the product nuclides. Thus, cyclic electron accelerators (LINACs or microtrons) are used for activation preferably. The predominant photonuclear reaction is of the ({gamma},n)-type. Thus, normally neutron-deficient nuclides are produced. These usually emit gamma rays, annihilation quanta and characteristic X-ray fluorescence, all of whom can be used for analytical evaluation. The spectrometry equipment is the same as used for the other activation techniques (semiconductor detectors, sodium iodide crystals in coincidence geometry). Being uncharged high energy photons have a large penetration power, thus do not suffer from strong matrix absorption. Although not having a detection power as large as in NAA (in the most cases), PAA offers several further convincing advantages, e.g. several elements not or hardly detectable by NAA can be analysed: Titanium, nickel, thallium, lead, bismuth and, in particular, the light elements carbon, nitrogen, oxygen, fluorine, phosphorus. Several typical applications will be described.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Sealed, UHV Compatible, Soft X-ray Detector Utilizing Gas Electron Multipliers

An advanced soft X-ray detector has been designed and fabricated for use in synchrotron experiments that utilize X-ray absorption spectroscopy in the study a wide range of materials properties. Fluorescence X-rays, in particular C{sub K} at 277eV, are converted in a low pressure gas medium, and charge multiplication occurs in two gas electron multipliers, fabricated in-house from glass reinforced laminate, to enable single photon counting. The detector satisfies a number of demanding characteristics often required in synchrotron environments, such as UHV compatibility compactness, long-term stability, and energy resolving capability.

43 PARTICLE ACCELERATORS↗

Progress on the Development of XRF Imaging and Analysis at the Siam Photon Laboratory

XRF imaging and analysis at the Siam Photon Laboratory have been recently developed for supporting various applications in x-ray micro analysis. An experimental setup for white beam x-ray fluorescent imaging has been installed at the beamline BL2 for elemental and quantitative analyses. A white micro beam of 163x170 {mu}m{sup 2}(FWHM) measured by wire scanning has been delivered to samples using a polycapillary x-ray half-lens. The fluorescent emissions of characteristic x-rays (1 keV and above) are detected by a Si-PIN detector. XRF imaging of Ni grids on supporting glass and XRF analysis on a trace-element standard were conducted for testing the apparatus. The test results on these samples as well as the necessary software developed for elemental identification and imaging are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast-scanning high-flux microprobe for biological X-ray fluorescence microscopy and microXAS

There is a growing interest in the biomedical community in obtaining information concerning the distribution and local chemical environment of metals in tissues and cells. Recently, biological X-ray fluorescence microscopy (XFM) has emerged as the tool of choice to address these questions. A fast-scanning high-flux X-ray microprobe, built around a recently commissioned pair of 200 mm-long Rh-coated silicon Kirkpatrick-Baez mirrors, has been constructed at BioCAT beamline 18ID at the Advanced Photon Source. The new optical system delivers a flux of 1.3 x 10{sup 12} photons s{sup -1} into a minimum focal spot size of {approx}3-5 {micro}m FWHM. A set of Si drift detectors and bent Laue crystal analyzers may be used in combination with standard ionization chambers for X-ray fluorescence measurements. BioCAT's scanning software allows fast continuous scans to be performed while acquiring and storing full multichannel analyzer spectra per pixel on-the-fly with minimal overhead time (<20 ms per pixel). Together, the high-flux X-ray microbeam and the rapid-scanning capabilities of the BioCAT beamline allow the collection of XFM and micro X-ray absorption spectroscopy (microXAS) measurements from as many as 48 tissue sections per day. This paper reports the commissioning results of the new instrument with representative XFM and microXAS results from tissue samples.

43 PARTICLE ACCELERATORS↗

Calibration of X-ray detectors in the 8 to 115 keV energy range and their application to diagnostics on the National Ignition Facility

The calibration of X-ray diagnostics is of paramount importance to the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory (LLNL). National Security Technologies LLC (NSTec) fills this need by providing a wide variety of calibration and diagnostic development services in support of the ongoing research efforts at NIF. The X-ray source in the High Energy X-ray lab utilizes induced fluorescence in a variety of metal foils to produce a beam of characteristic X rays ranging from 8 to 111 keV. Presented are the methods used for calibrating a High Purity Germanium detector, which has been absolutely calibrated using radioactive check sources, compared against a silicon photodiode calibrated at Physikalisch Technische Bundesanstalt (PTB). Also included is a limited presentation of results from the recent calibration of the upgraded Filter Fluorescer X ray Spectrometer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-Ray Diffraction on Mars: Scientific Discoveries Made by the CheMin Instrument

The Mars Science Laboratory Curiosity landed in Gale crater in August 2012 with the goal to identify and characterize habitable environments on Mars. Curiosity has been studying a series of sedimentary rocks primarily deposited in fluviolacustrine environments approximately 3.5 Ga. Minerals in the rocks and soils on Mars can help place further constraints on these ancient aqueous environments, including pH, salinity, and relative duration of liquid water. The Chemistry and Mineralogy (CheMin) X-ray diffraction and X-ray fluorescence instrument on Curiosity uses a Co X-ray source and charge-coupled device detector in transmission geometry to collect 2D Debye-Scherrer ring patterns of the less than 150 micron size fraction of drilled rock powders or scooped sediments. With an angular range of approximately 2.52deg 20 and a 20 resolution of approximately 0.3deg, mineral abundances can be quantified with a detection limit of approximately 1-2 wt. %. CheMin has returned quantitative mineral abundances from 16 mudstone, sandstone, and aeolian sand samples so far. The mineralogy of these samples is incredibly diverse, suggesting a variety of depositional and diagenetic environments and different source regions for the sediments. Results from CheMin have been essential for reconstructing the geologic history of Gale crater and addressing the question of habitability on ancient Mars.

Rampe, E. B.↗

The Lunar Atmosphere as a Cosmic-Ray Detector

The recent discovery of a tenuous sodium (Na) atmosphere on the Moon and Mercury has renewed interest in studying the lunar atmosphere since the physics involved for the two bodies is thought to be of similar nature. Na came as a surprise because it had been missed by in situ UV measurements made during the Apollo program. The new lunar observations involve the visible D1 (5896 ) and D2 (5890 ) wavelengths which are highly efficient at scattering sunlight. Although its lunar source and morphology is still not completely understood, Na is present as a collisionless exosphere - apparently in the form of a cometary-type coma with a tail that can extend hundreds of lunar radii during Leonid showers. The global shape of the atmosphere, in particular for the shaded antisolar side, has been modelled by Smyth. Since planetary atmospheres can be used as cosmic-ray (CR) spectrometers by means of their fluorescence excited by CR-induced air shower particles, the subject of the Moon s atmosphere as a CR detector will be discussed here.

Wilson, T. L.↗

TU-AB-201-09: Calibration of An Element of a New Directional Pd-103 Planar Source Array

Purpose: The CivaSheet™ is a new directional Pd-103 planar source array, with a variable number of discrete source elements referred to as “dots”. Each dot consists of a polymer capsule containing {sup 103}Pd and a gold shield that attenuates radiation on one side of the device to define hot and cold dose regions. Fluorescence from the gold shield is observed in the dot spectrum. Since CivaSheet™ is a planar directional source, conventional methods used for calibration of azimuthally symmetric sources are not applicable. The purpose of this work is to establish an air-kerma-strength standard and a transfer to a well chamber for clinical calibration. Methods: Primary air-kerma strength measurement of the dots was performed using a variable-aperture free-air chamber (VAFAC). Charge measurements were recorded using a well chamber with a custom insert. Anisotropy measurements were performed using a Sodium-Iodide detector. Spectral measurements were performed using a low-energy germanium detector and compared to a source without gold. The dot geometry was modeled using the MCNP6 radiation transport code. Results: Air-kerma strength measurements of a batch of four dots performed with the VAFAC were within ±1.5% of the average measured value and the measurement precision was within ±0.5%. Anisotropy measurements indicated uniform emission within the measurement uncertainty for the solid angle defining the VAFAC aperture used. Charge measurements of each dot using the well chamber in four cardinal angle source orientations were within ±1.5% of the average measured values. The spectral study of a dot resulted in identification of fluorescence from the gold shield and primary spectral energies that were compared to MCNP6 simulations. Conclusion: Calibration procedures for the new directional Pd-103 source dot were established for future clinical use, based on the results of experimental and Monte Carlo investigations. This work was partially supported by NCI contract (HHSN261201200052C) through CivaTech Oncology Inc.

60 APPLIED LIFE SCIENCES↗

X-ray Fluorescence (XRF) Assay Using Laser Compton Scattered (LCS) X-rays

Laser Compton Scattered (LCS) X-rays are produced as a result of the interaction between accelerated electrons and a laser beam. The yield of LCS X-rays is dependent on the laser power, angle of collision between interacting particles, and the electron linear accelerator's (linac) electron beam energy and its current. One of our research goals at the Idaho Accelerator Center (IAC) focuses on applications such as detection and imaging of fissionable isotopes for nuclear non-proliferation, safeguards and homeland security. Quasi monochromatic LCS X-rays offer much better signal-to-noise ratios for such applications. The energy of LCS X-rays is tunable, that enable element-specific analysis. Two sharp 36.5 keV and 98.4 keV LCS peaks were observed in two separate experiments based on electron beams tuned at 32 MeV and 37 MeV, that were brought in collision with the (Power){sub peak} = 4 GW Nd.YAG laser operating at 532 nm and 266 nm wavelengths. The linac was operating at 60 Hz with an electron beam pulse length of about 50 ps and a peak current of about 7 A. We exploited X-ray fluorescence (XRF) techniques to identify elemental K{alpha}{sub 1}, K{alpha}{sub 2}, and K{beta}{sub 1} lines in a high-purity germanium (HPGe) detector, with a 0.5 mm thick Beryllium (Be) absorbing layer, emitted from tin (Sn), cadmium (Cd), silver (Ag), gold (Au), and lead (Pb) foils with thicknesses ranging from 25-500 {mu}m, following absorption of 36.1 keV and 98.4 keV LCS X-rays. These reference foils were used for the proof of principle, and some have atomic numbers near to that of relevant fission products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗