Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fire Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Pyroshock Environments Characterized for Spacecraft Missions

Pyrotechnic shock, or pyroshock, is the transient response of a structure to loading induced by the ignition of pyrotechnic (explosive or propellant activated) devices. These devices are typically used to separate structural systems (e.g., separate a spacecraft from a launch vehicle) and deploy appendages (e.g., solar panels). Pyroshocks are characterized by high peak acceleration, high-frequency content, and short duration. Because of their high acceleration and high-frequency, pyroshocks can cause spaceflight hardware to fail. Verifying by test that spaceflight hardware can withstand the anticipated shock environment is considered essential to mission success. The Earth Observing System (EOS) AM-1 spacecraft for NASA's Mission to Planet Earth is scheduled to be launched on an Atlas IIAS vehicle in 1999, and the NASA Lewis Research Center is the launch vehicle integrator for this NASA Goddard Space Flight Center spacecraft. The EOS spacecraft was subjected to numerous ground shock tests to verify that its scientific instruments and avionics components will withstand the shock-induced vibration produced when the spacecraft separates from the launch vehicle. Shock test data from these tests represent the third largest available pyroshock database in the United States. Future spacecraft missions will directly benefit from the knowledge gained from these tests. The payload separation system used for EOS is a new system that operates by firing six separation nuts. This system was tested to verify its functional operation and to characterize the resulting shock levels. The launch vehicle contractor (Lockheed Martin Astronautics) and spacecraft contractor (Lockheed Martin Missiles & Space) completed 16 separation test firings. This resulted in an unusually large amount of pyroshock data. Typically, only one or two pyroshock test firings are performed for a spacecraft mission. Because of the size of this separation system shock database, engineers were able to perform unique statistical analyses to characterize the distribution of the test data. For example, it was proven that the shock data follow a lognormal distribution, a concept often assumed but rarely proven. The test-to-test repeatability of the shock source level was analyzed, and the effects of various test configurations and separation nut production lots were examined and quantified. Engineers investigated the change in shock level as the shock traveled from the spacecraft separation interface to the avionics components of the upper stage and analyzed the effects of the structural fidelity (simulator versus real) of the components and their weight on vibrational response. In addition, the shock attenuation with distance and across joints was quantified and compared with concepts originally generated in 1970, and the effects of separation nut preload and firing sequences effects were examined. Because of this EOS shock testing and the analyses performed at NASA Lewis, a significant amount of new information on pyroshock and its characteristics is now available to the aerospace industry. We hope that this information will help future spacecraft test planners to perform better and cheaper spacecraft separation shock tests and to better understand their test data.

Hughes, William O.↗

Battery activation system

Initiator is fired to set off gas generator; gas flows into manifold and as gas pressure increases, chlorotrifluoroethylene diaphragms transfer force to polyethylene bags filled with electrolyte. Small membrane at base of each bag is ruptured, allowing electrolyte to flow into cells.

Sollo, C.↗

Planetary Protection Considerations for Life Support and Habitation Systems

Life support systems for future human missions beyond low Earth orbit may include a combination of existing hardware components and advanced technologies. Discipline areas for technology development include atmosphere revitalization, water recovery, solid waste management, crew accommodations, food production, thermal systems, environmental monitoring, fire protection and radiation protection. Life support systems will be influenced by in situ resource utilization (ISRU), crew mobility and the degree of extravehicular activity. Planetary protection represents an additional set of requirements that technology developers have generally not considered. Planetary protection guidelines will affect the kind of operations, processes, and functions that can take place during future exploration missions, including venting and discharge of liquids and solids, ejection of wastes, use of ISRU, requirements for cabin atmospheric trace contaminant concentrations, cabin leakage and restrictions on what materials, organisms, and technologies that may be brought on missions. Compliance with planetary protection requirements may drive development of new capabilities or processes (e.g. in situ sterilization, waste containment, contaminant measurement) and limit or prohibit certain kinds of operations or processes (e.g. unfiltered venting). Ultimately, there will be an effect on mission costs, including the mission trade space. Planetary protection requirements need to be considered early in technology development programs. It is expected that planetary protection will have a major impact on technology selection for future missions.

Barta, Daniel J.↗

Safety considerations involved in testing, checkout and launch operations at Cape Kennedy

This paper concerns itself with identifying safety problems associated with launch operations conducted during preparations for manned space flights at Cape Kennedy. This includes transportation and assembly of large space vehicles in the Vehicle Assembly Building, rollout to Launch Pad 39, test, checkout, and the launch countdown. Under these broad categories, the risks of fuel and oxidizer loading, installation of pyrotechnics, and similar hazardous operations are discussed. The many aspects for fire and rescue requirements are examined. These encompass the water deluge systems on the Mobile Service Structure and the Mobile Launcher, the insulated fire and rescue tractor, slide wire escape system, fire proximity suits, self-contained breathing apparatus and emergency cutting tools. In addition, written procedures for tests, emergencies, rescue and backout, as well as certification of personnel and TV monitoring of the launch system are detailed.-

Bolger, P. H.↗

A feasibility study: California Department of Forestry and Fire Protection utilization of infrared technologies for wildland fire suppression and management

NASA's JPL has completed a feasibility study using infrared technologies for wildland fire suppression and management. The study surveyed user needs, examined available technologies, matched the user needs with technologies, and defined an integrated infrared wildland fire mapping concept system configuration. System component trade-offs were presented for evaluation in the concept system configuration. The economic benefits of using infrared technologies in fire suppression and management were examined. Follow-on concept system configuration development and implementation were proposed.

Nichols, J. D.↗

QUIC-URB and QUIC-fire extension to complex terrain: Development of a terrain-following coordinate system

Ensemble-based approaches to prescribed fire planning cannot be supported by CFD-based models like FIRETEC and WFDS because they are too computationally expensive and cannot leverage LES approaches like CAWFE and WRF-SFIRE because too coarse of resolution. QUIC-Fire was developed to fill this gap but it cannot currently address complex terrain, typical for instance of the Western United States. In this paper, we describe the extension of the diagnostic wind model QUIC-URB, the wind engine of QUIC-Fire, to a terrain-following coordinate system. In particular, the paper presents the mathematical derivation of the wind solver leading to a linear system of equations that are solved through the successive over-relaxation method. The model is validated against a standard test used in previous works (the Askervein Hill) and against a new dataset from measurements in the Socorro Mountains, New Mexico. The terrain-following implementation captured the correct phenomenology for the isolated Askervein Hill, with a wind speed up at the top of the hill. We report the model agreed well with measurements on the upwind side of the peak, but overestimated speed-up on the downwind side of the hill. This is due to the inability of the model to generate flow separation and wake-eddy dynamics. On a common laptop, the divergence-free wind field was obtained in 6 s, making the solver appealing for coupled fire–atmosphere simulations. The Socorro Mountain was highly complex, with many cliff faces, peaks, and valleys. Although the model captures the magnitude and direction of inlet and outlet areas of the domain, it performs rather poorly in the valley region and in the regions near the steep cliffs. Hence, the model shows good agreement with data in areas of open sloped terrain but lacks in areas where flow separation and thermally driven effects may be present (neither effect was addressed in this work). Results highlight that future work should focus on the implementation of parameterizations of wake-eddies, similar to QUIC-URB’s building parameterizations, and on thermodynamic-driven flow.

54 ENVIRONMENTAL SCIENCES↗

Drinking from the Fire Hose: Why the Flight Management System Can Be Hard to Train and Difficult to Use

The Flight Management Computer (FMC) and its interface, the Multi-function Control and Display Unit (MCDU) have been identified by researchers and airlines as difficult to train and use. Specifically, airline pilots have described the "drinking from the fire-hose" effect during training. Previous research has identified memorized action sequences as a major factor in a user s ability to learn and operate complex devices. This paper discusses the use of a method to examine the quantity of memorized action sequences required to perform a sample of 102 tasks, using features of the Boeing 777 Flight Management Computer Interface. The analysis identified a large number of memorized action sequences that must be learned during training and then recalled during line operations. Seventy-five percent of the tasks examined require recall of at least one memorized action sequence. Forty-five percent of the tasks require recall of a memorized action sequence and occur infrequently. The large number of memorized action sequences may provide an explanation for the difficulties in training and usage of the automation. Based on these findings, implications for training and the design of new user-interfaces are discussed.

Sherry, Lance↗

Risks and issues in fire safety on the Space Station

A fire in the inhabited portion of a spacecraft is a greatly feared hazard, but fire protection in space operations is complicated by two factors. First, the spacecraft cabin is an enclosed volume, which limits the resources for fire fighting and the options for crew escape. Second, an orbiting spacecraft experiences a balance of forces, creating a near-zero-gravity (microgravity) environment that profoundly affects the characteristics of fire initiation, spread, and suppression. The current Shuttle Orbiter is protected by a fire-detection and suppression system whose requirements are derived of necessity from accepted terrestrial and aircraft standards. While experience has shown that Shuttle fire safety is adequate, designers recognize that improved systems to respond specifically to microgravity fire characteristics are highly desirable. Innovative technology is particularly advisable for the Space Station, a forthcoming space community with a complex configuration and long-duration orbital missions, in which the effectiveness of current fire-protection systems is unpredictable. The development of risk assessments to evaluate the probabilities and consequences of fire incidents in spacecraft are briefly reviewed. It further discusses the important unresolved issues and needs for improved fire safety in the Space Station, including those of material selection, spacecraft atmospheres, fire detection, fire suppression, and post-fire restoration.

Friedman, Robert↗

Development of aircraft lavatory compartments with improved fire resistance characteristics. Phase 4: Sandwich panel decorative ink development

Five chemically different resin systems with improved fire resistance properties were studied for a possible screenprinting ink application. Fire resistance is hereby defined as the cured ink possessing improvements in flammability, smoke emission, and thermal stability. The developed ink is for application to polyvinyl fluoride film. Only clear inks without pigments were considered. Five formulations were evaluated compared with KC4900 clear acrylic ink, which was used as a baseline. The tests used in the screening evaluation included viscosity, smoke and toxic gas emission, limiting oxygen index (LOI), and polyvinyl fluoride film (PVF) printability. A chlorofluorocarbon resin (FPC461) was selected for optimization studies. The parameters for optimization included screenprinting process performance, quality of coating, and flammability of screenprinted 0.051-mm (0.002-in.) white Tedlar. The quality of the screenprinted coating on Tedlar is dependent on viscosity, curing time, adhesion to polyvinyl fluoride film, drying time (both inscreen and as an applied film), and silk screen mesh material and porosity.

Jayarajan, A.↗

Changes in marsh soils for six months after a fire

An examination is conducted of changes in soil-nutrient levels in marsh systems after a fire, in conjunction with studies of particulates and gases generated by such biomass combustion. Attention is given to data covering six months after the fire. It is noted that changes in soil property occur at different times after the fire, and persist for different intervals; this implies a need for long-term postfire observations. The marshes studied were representative of a variety of graminoid wetlands in the southeastern U.S. which periodically burn either naturally or upon prescription. Nitrogen transformations in flooded soils differ from those in well-drained ones.

Schmalzer, Paul A.↗

Characterizing Plug Load Energy Use and Savings Potential in Army Buildings

The Assistant Secretary of the Army (Installations, Energy and Environment) tasked the Pacific Northwest National Laboratory to examine plug loads in typical Army buildings. Plug loads (also known as miscellaneous electric loads (MELs)) represent the electricity used by appliances and devices that are plugged in or hardwired and serve functions outside of a building’s core end uses. Common plug loads include computers, printers, copiers, networking devices, refrigerators, and vending machines. They also include personal electronic devices such as televisions, smart phones, tablets, and gaming systems. Examples of hardwired MELs include elevators, air compressors, and fire and security systems. The findings from this study confirm that significant energy is consumed within Army buildings by plug load devices and hardwired MEL equipment. A number of opportunities are identified for reducing unnecessary energy use that could save the Army over $5 million per year when broadly applied. Army regulations clearly spell out expectations for the purchase and operation of information technology equipment (computers, laptops, monitors, printers, and multi-function devices). However, the policies regarding the shutdown or activation of sleep and other lower power modes after 30 minutes of inactivity (15 minutes for monitors) do not appear to be consistently followed. There are many effective approaches and pathways for impacting change as it relates to improving awareness, implementing measures, and adjusting behaviors to identify and reduce plug load energy use. The Army should prioritize and consider deploying all of these to better understand and manage plug load equipment to save energy and enhance resilience across their facilities. Engaging the building occupants who use these devices daily via outreach and education should be a strong component of the strategy. The focus should be on reducing waste without sacrificing productivity or the benefits that many of these devices provide. Continued evaluation of plug loads beyond that performed here is important to gather lessons from additional building and equipment types, and to stay aware of evolving device technology and management options. This will highlight additional needs for policies, best practices, control technologies, and education of personnel to achieve real reductions in energy waste from plug load equipment. It is recommended that this study may serve as the foundation for a broader and sustained focus on plug loads and MELs, towards simultaneously enhancing the productivity, readiness, and resilience of the Army while reducing energy use and demand, and freeing up resources to better support the mission.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Formation of stored heat by means of bled steam during times of load reduction and its use in peak load times

Technical possibilities and economic advantages of integrating hot water storage systems into power plants fired with fossil fuels are discussed. The systems can be charged during times of load reduction and then used for back-up during peak load periods. Investment costs are higher for such systems than for gas turbine power plants fired with natural gas or light oil installed to meet peak load demand. However, by improving specific heat consumption by about 1,000 kcal/k ohm, which thus reduces the related costs, investment costs will be compensated for, so that power production costs will not increase.

Bitterlich, E.↗

Power System Wildfire Risks and Potential Solutions: A Literature Review & Proposed Metric

Several fire risk evaluation, fire tracking, and fire response resources are available. The risk metrics and fire response programs are sometimes modified to include a power system context. The risk metrics often evaluate the risk of fires causing power system faults or outages, especially on transmission systems. The response programs are modified to ensure the safety of power system equipment and first responders as well as to coordinate power system outages to both ensure safety during an active fire and prevent fire ignition during high risk periods. Although some aspects of wildfire responses have been adapted to include power system concerns, adaptations to power system operations and maintenance to include wildfire risks and responses are still nascent. In particular, a risk metric that evaluates the potential for power system components to ignite wildfires is needed to help guide power system upgrade efforts and power system fire safety measures. This document serves as a brief literature review of wildfire risk metrics and response programs and how they relate to power systems. It also includes a proposed risk metric and structure for describing the risk of a power system component igniting a fire.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Considerations for Fire Service Response to Residential Battery Energy Storage System Incidents

Renewable energy sources (e.g., rooftop photovoltaics, wind turbines) are capable of addressing our grid-level energy challenges by reducing environmental impacts, increasing resiliency, and increasing the supply of input energy. However, renewable energy sources alone are not a complete solution. The generation of power from major renewable energy sources fluctuates with the weather, creating significant challenges in matching electrical power generation to electrical power consumption. The value of renewable power generation sources is multiplied when paired with battery energy storage systems (ESS), which can store excess power generated from renewable energy sources when it is not consumed and deliver that power later when demand exceeds base power generation. Residential ESS units are frequently installed to support renewable energy initiatives by storing energy from intermittent sources such as photovoltaic panels. Residential ESS units also offer an alternative to gas-powered generators or other backup power means. Lithium-ion batteries are the most common residential ESS technology due to their affordability and energy density. Though lithium-ion systems come with benefits, there is also a risk of thermal runaway within this technology which can result in flammable gas release, fire, and explosion. As the installations of these products increase, the frequency of response to fire incidents involving these products will increase. In response to this new and evolving hazard, UL Solutions (ULS) and UL Fire Safety Research Institute (FSRI) have partnered with the International Association of Fire Fighters (IAFF) to conduct a series of large-scale tests sponsored by the US Department of Energy to characterize the challenges for fire fighters responding to fires involving residential energy storage systems. The project focuses on developing size-up and tactical considerations to support the fire service in navigating the evolving modern fireground.

25 ENERGY STORAGE↗

Combustion Processes in the Aerospace Environment

The aerospace environment introduces new and enhanced fire hazards because the special atmosphere employed may increase the frequency and intensity of fires, because the confinement associated with aerospace systems adversely affects the dynamics of fire development and control, and because the hostile external environments limit fire control and rescue operations. Oxygen enriched atmospheres contribute to the fire hazard in aerospace systems by extending the list of combustible fuels, increasing the probability of ignition, and increasing the rates of fire spread and energy release. A system for classifying atmospheres according to the degree of fire hazard, based on the heat capacity of the atmosphere per mole of oxygen, is suggested. A brief exploration of the dynamics of chamber fires shows that such fires will exhibit an exponential growth rate and may grow to dangerous size in a very short time. Relatively small quantities of fuel and oxygen can produce a catastrophic fire in a closed chamber.

Huggett, Clayton↗