Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Failure Rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Topology Optimization with a Manufacturability Objective

Part distortion and residual stress are critical factors for metal additive manufacturing (AM) because they can lead to high failure rates during both manufacturing and service. We present a topology optimization approach that incorporates a fast AM process simulation at each design iteration to provide predictions of manufacturing outcomes (i.e., residual stress, distortion, residual elastic energy) that can be optimized or constrained. The details of the approach and implementation are discussed, and an example design is presented that illustrates the efficacy of the method.

42 ENGINEERING↗

Operating Lifetime Study of Ultraviolet (UV) Light-Emitting Diode (LED) Products

Light-emitting diodes (LEDs) can emit radiation that spans the range from near infrared (IR) to all three bands of ultraviolet (UV) radiation: UV-A, UV-B, and UV-C. This report focuses on LEDs that emit in one of the three UV bands because they have the potential to displace lowpressure mercury vapor (LPMV) lamps in a variety of industrial processes, including ink and adhesive curing, medical procedures, and germicidal disinfection. However, before emerging UV LED technologies can displace LPMV lamps, the efficiency and reliability of these sources must meet the user’s expectations in each application. An earlier report focused on the construction and initial performance of commercial UV LED products in radiometric and current-voltage (IV) tests [1]. This report focuses on the long-term performance and reliability of the same set of commercial products. The intent of this report is to provide to the lighting industry a benchmark of the state of UV LEDs as of mid-2021 when these products were purchased. Understanding the failure modes and failure rates of UV LEDs is important in improving UV product reliability at the LED, lamp, and luminaire level and is critical to developing products with higher efficiency, lower carbon footprint, and significantly reduced environmental impact than LPMV lamps.

42 ENGINEERING↗

Enhanced Component Performance Study: Motor Driven Pumps 1998–2022

This report presents an enhanced performance evaluation of motor-driven pumps (MDPs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2022 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The MDP failure modes considered for standby systems are fail to start (FTS), fail to run (FTR) for one hour of operation (FTR=1H), FTR after one hour of operation (FTR>1H), and for normally running systems FTS and FTR. An eight-hour unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire study period. The following increasing trends were identified for MDPs for the most recent 10-year period: (1) Standby MDP frequency of start demands (demands per reactor year), (2) Standby MDP frequency of FTR=1H hours (hours per reactor year), (3) Standby MDP frequency of FTR>1H hours, and (4) Normally running MDP frequency of run hours. The following decreasing trends were identified for MDPs for the most recent 10-year period: (1) Standby MDP FTR=1H failure probability, (2) Normally running MDP FTR failure rate, (3) Standby MDP unavailability, (4) Standby MDP total unreliability (8-hour mission), and (5) Normally running MDP total unreliability (8-hour mission).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Instrumentation for the Investigation of Pitch Bearing Design and Reliability

Recently, there has been an increasing level of industry interest in pitch system and pitch bearing reliability. Pitch bearings are used in wind turbines to connect the blade root to the hub. Some populations of pitch bearings have demonstrated a 12% failure rate in 20 years. As rotor diameters continue to increase for tall land-based and offshore wind turbines, pitch bearings are becoming even larger in diameter, which can make them vulnerable to deflections and consequent stress concentrations. There is an increased need to more accurately study pitch bearing deformations, misalignment, load distributions, and contact stresses. A significant body of work has investigated fatigue lives and wear characteristics of pitch bearings on ground-based test rigs. NREL has also recently begun a research program related to pitch bearing reliability, recognizing its growing importance for wind turbines. The purpose of this paper is to describe a set of instrumentation that was recently installed on a 1.5 MW wind turbine at the NREL Flatirons Campus and provide an example data set. To the authors' knowledge, this will be the first publicly available pitch bearing data collection campaign on an operational wind turbine.

17 WIND ENERGY↗

Increasing Reliability and Safety of Hydrogen Components - Reliability Data Collection

Come learn about the new Hydrogen Component Reliability Database (HyCReD) and participate in discussions on hydrogen component reliability data collection, collaboration, and analysis. Funded by the U.S. Department of Energy's Office of Energy Efficiency and Renewable Energy under the Hydrogen and Fuel Cell Technologies Office, HyCReD is a collaborative project between the National Renewable Energy Laboratory, the University of Maryland, and hydrogen stakeholders to improve safety reliability for hydrogen facilities by integrating risk reduction methodologies and component reliability data taxonomies that support hydrogen infrastructure failure rate analysis.

component↗

Performance Test of Mini LVDT - ELVIS

The Institute for Energy (IFE) Technology has been a pioneer in the development of Linear Variable Differential Transformers (LVDTs) for in-pile testing, deploying over 2,200 units in various reactor environments with less than a 10% failure rate after five years of operation. This report focuses on the performance testing of IFE’s Mini LVDT, a compact sensor ideal for material test reactor experiments. The Mini LVDT, with a limited range of +/- 1.5 mm, offers excellent performance comparable to larger LVDTs, making it valuable in space-constrained applications. The development of an Enhanced Linear Variable Intrinsic Sensor (ELVIS) with internal temperature monitoring capabilities represents a significant advancement, addressing the critical need for real-time, accurate measurements in high-radiation and high-temperature environments. Two ELVIS prototypes were evaluated in terms of both temperature and displacement, showcasing promising results, though challenges with noise during temperature measurements were identified. This report summarizes the rigorous testing performed at Idaho National Laboratory (INL) and highlights the potential applications of Mini LVDTs and ELVIS in nuclear and other high-precision industries.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of LLM-Generated Kokkos Code Using Compile-Time and Run-Time Testing

Due to the growing use of large language models (LLMs) by developers and researchers, it has become essential to reliably evaluate their ability to generate code that uses specialized libraries. We explore the use of compile-time and run-time evaluation of LLM-generated Kokkos code through extending the methods used by OpenAI with the HumanEval dataset. Our evaluation framework is based on the first 40 prompts from the Kokkos138 dataset. We start by discussing two different forms of LLM prompting, using entirely plain English or providing pseudocode for added context. These two methods are used to generate Kokkos code with the Llama-3.1-8B-Instruct and CodeQwen1.5-7B-Chat models. We found that both forms of prompting led to high failure rates and difficulties with reliably parsing LLM-generated code, while prompts with pseudocode for context generally led to improved results on more complicated tests.

97 MATHEMATICS AND COMPUTING↗

Extending Component Lifetime And Improving Inverter Reliability (ECLAIIR)

Inverter reliability remains one of the most persistent challenges limiting the performance, availability, and economic viability of utility‑scale photovoltaic (PV) plants. Industry data consistently show that inverters account for the highest share of corrective maintenance events and unplanned outages across PV fleets. These failures result in energy losses, increased O&M costs, and reduced confidence in long‑term solar asset performance. Motivated by these challenges, this project—Extending Component Lifetime and Improving Inverter Reliability (ECLAIIR)—was undertaken to systematically investigate inverter degradation and failure mechanisms, develop predictive maintenance capabilities, and establish data‑driven pathways to improve service life and reduce the Levelized Cost of Energy (LCOE) for large‑scale PV systems. The primary goal of the project was to identify pre‑failure signatures in string inverters using both lab‑based accelerated lifetime testing and field‑based data and to develop predictive maintenance algorithms that can anticipate inverter faults before they occur. Through collaboration with inverter testing laboratory, solar PV plant owner, and failure‑analysis experts, the project advanced the technical understanding of inverter reliability. By instrumenting inverters with thermistors, humidity sensors, power‑quality meters, and acoustic sensors, the research established how multiple sensing modalities can reliably detect deviations from normal behavior hours to days before failure. These findings substantially enhance scientific understanding of inverter failure kinetics and provide the PV industry with the most comprehensive cross‑OEM characterization of early‑stage failure indicators reported to date. Technically, the project demonstrated the effectiveness of predictive maintenance by developing and validating the PreDICT (Predictive Diagnostics of PV Inverters Using Condition Monitoring and Trend Analysis) framework—a multi‑layer diagnostic architecture combining peer‑to‑peer analytics, historical trend modeling, and advanced machine‑learning techniques such as the Sequential Conditional Variational Autoencoder (SCVAE). This predictive model achieved more than 90% accuracy in detecting pre‑failure conditions and provided up to four days of lead time before inverter failure in field scenarios. Economically, the project’s LCOE analysis showed that predictive maintenance can reduce lifetime energy losses and minimize corrective maintenance interventions. Modeling indicated that, depending on inverter failure rates and replacement timelines, predictive maintenance can significantly reduce LCOE impacts associated with inverter downtime: from as high as 19.4% under conventional maintenance strategies to 0.1%–10.17% when predictive analytics are adopted. These results confirm that predictive maintenance is both technically feasible and economically advantageous for utilities and plant operators. The project’s findings also have broad public benefit. By improving inverter reliability and reducing downtime, predictive maintenance directly increases electricity generation from existing PV assets. Enhanced reliability lowers operational costs for utilities, which can translate over time into lower energy costs for consumers. Furthermore, the project’s technical publications, conference presentations, and industry workshops ensure that knowledge gained is shared broadly across the solar industry, supporting workforce development and enabling utilities of all sizes to adopt modern asset‑health monitoring practices. The retrofitting case study and service‑life prediction framework further support informed decision‑making for aging PV fleets, helping operators extend system life and reduce electronic waste. In summary, the ECLAIIR project significantly advanced the state of knowledge on inverter degradation, demonstrated the technical and economic value of predictive maintenance, and delivered actionable tools and insights that support more reliable, cost‑effective, and sustainable PV plant operation. The outcomes of this project will continue to inform utility practices, guide inverter design improvements, and strengthen the long‑term performance of solar assets nationwide.

14 SOLAR ENERGY↗

AGR-5/6/7 Irradiation Experiment Fission Product Mass Balance

This report presents the fission product mass balance for the AGR-5/6/7 TRISO fuel irradiation experiment. The fission product inventories deposited on capsule components outside of the fuel (e.g., stainless-steel shells, graphite holders, Grafoil disks, and associated hardware) were quantified as part of the post-irradiation examination (PIE) to assess the performance of this fuel. Comparisons were made between these inventories and depletion calculations, non-destructive measurements of fuel fission product inventories in the intact fuel compacts, prior AGR experiments, and results from among each of the five distinct AGR-5/6/7 capsules. The data served as estimates of the condensable fission products released from the fuel during irradiation. Excluding Capsule 1 (which experienced accidental damage during irradiation) and Capsule 3 (which was tested at very high irradiation temperatures of >1300°C), the results indicate that the AGR-5/6/7 fuel performed comparably to fuel from earlier AGR experiments. The mass balance results were also used to estimate the number of particles with in-pile SiC failures. Subject to the assumptions made in these estimates, and excluding Capsules 1 and 3, the in-pile SiC failure rates for AGR-5/6/7 are comparable to those observed in AGR-2.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neonatal respiratory support strategies—short and long-term respiratory outcomes

Mechanical ventilation (MV), although life-saving, is associated with chronic respiratory morbidity in both preterm and term born infants. New ventilation modes have been developed with the aim of minimising lung injury. These include invasive and non-invasive respiratory support strategies, techniques for less invasive surfactant administration (LISA) and closed-loop automated oxygen control (CLAC) systems. Increasingly, newborn infants with signs of respiratory distress are stabilised on continuous positive airway pressure (CPAP) and receive LISA. Early CPAP when compared to mechanical ventilation reduced the incidence of BPD and respiratory morbidity at 18 to 22 months corrected age. Nasal intermittent positive pressure ventilation reduced treatment failure rates compared to CPAP, but not bronchopulmonary dysplasia (BPD). LISA compared with intubation and surfactant delivery reduced BPD, but there is no evidence from randomised trials regarding long-term respiratory and neurodevelopmental outcomes. Synchronisation of positive pressure inflations with the infant's respiratory efforts used with volume targeting should be applied for infants requiring intubation as this strategy reduces BPD. A large RCT with long term follow up data demonstrated that prophylactic high frequency oscillatory ventilation (HFOV) improved respiratory and functional outcomes at school age, but those effects were not maintained after puberty. CLAC systems appear promising, but their effect on long term clinical outcomes has not yet been explored in randomised trials. Further studies are required to determine the role of newer ventilation modes such as neurally adjusted ventilator assist (NAVA). All such respiratory support strategies should be tested in randomised controlled trials powered to assess long-term outcomes.

Kaltsogianni, Ourania↗

Investigation of the Effect of Gate Oxide Screening with Adjustment Pulse on Commercial SiC Power MOSFETs

This paper presents a method to recover the negative threshold voltage shift during high field gate oxide screening of 1.2 kV 4H-SiC MOSFETs with an additional adjustment gate voltage pulse. To reduce field failure rates of the MOSFETs in operation, manufacturers perform a screening treatment to remove devices with extrinsic defects in the oxide. Current gate oxide screening procedures are limited to oxide fields at or below ~9 MV/cm for short durations (<1 s), which is not enough to remove all the devices with extrinsic defects. The results show that by implementing a lower field gate pulse, the threshold voltage shift can be partially recovered, and therefore the maximum screening field and time can be increased. However, both the initial screening pulse and the adjustment pulse require careful calibration to prevent significant degradation of the device threshold voltage, on-resistance, interface state density, or intrinsic lifetime. With a well calibrated set of pulses, higher screening fields can be utilized without significantly damaging the devices. This leads to an improvement in the overall screening efficiency of the process, reducing the number of devices with extrinsic oxide defects entering the field, and improving the reliability of the SiC MOSFETs in operation.

42 ENGINEERING↗

Amyloidogenesis: What Do We Know So Far?

The study of protein aggregation, and amyloidosis in particular, has gained considerable interest in recent times. Several neurodegenerative diseases, such as Alzheimer’s (AD) and Parkinson’s (PD) show a characteristic buildup of proteinaceous aggregates in several organs, especially the brain. Despite the enormous upsurge in research articles in this arena, it would not be incorrect to say that we still lack a crystal-clear idea surrounding these notorious aggregates. In this review, we attempt to present a holistic picture on protein aggregation and amyloids in particular. Using a chronological order of discoveries, we present the case of amyloids right from the onset of their discovery, various biophysical techniques, including analysis of the structure, the mechanisms and kinetics of the formation of amyloids. We have discussed important questions on whether aggregation and amyloidosis are restricted to a subset of specific proteins or more broadly influenced by the biophysiochemical and cellular environment. The therapeutic strategies and the significant failure rate of drugs in clinical trials pertaining to these neurodegenerative diseases have been also discussed at length. At a time when the COVID-19 pandemic has hit the globe hard, the review also discusses the plausibility of the far-reaching consequences posed by the virus, such as triggering early onset of amyloidosis. Finally, the application(s) of amyloids as useful biomaterials has also been discussed briefly in this review.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Target Selection and Validation of DESI Luminous Red Galaxies

The Dark Energy Spectroscopic Instrument (DESI) is carrying out a five-year survey that aims to measure the redshifts of tens of millions of galaxies and quasars, including 8 million luminous red galaxies (LRGs) in the redshift range 0.4 < z ≲ 1.0. Here we present the selection of the DESI LRG sample and assess its spectroscopic performance using data from Survey Validation (SV) and the first two months of the Main Survey. The DESI LRG sample, selected using g, r, z, and W1 photometry from the DESI Legacy Imaging Surveys, is highly robust against imaging systematics. The sample has a target density of 605 deg -2 and a comoving number density of 5 × 10 -4 h 3 Mpc -3 in 0.4 < z < 0.8; this is a significantly higher density than previous LRG surveys (such as SDSS, BOSS, and eBOSS) while also extending to z ~ 1. After applying a bright star veto mask developed for the sample, 98.9% of the observed LRG targets yield confident redshifts (with a catastrophic failure rate of 0.2% in the confident redshifts), and only 0.5% of the LRG targets are stellar contamination. The LRG redshift efficiency varies with source brightness and effective exposure time, and we present a simple model that accurately characterizes this dependence. In the appendices, we describe the extended LRG samples observed during SV.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance of the Quasar Spectral Templates for the Dark Energy Spectroscopic Instrument

Abstract Millions of quasar spectra will be collected by the Dark Energy Spectroscopic Instrument (DESI), leading to a fourfold increase in the number of known quasars. High-accuracy quasar classification is essential to tighten constraints on cosmological parameters measured at the highest redshifts DESI observes ( z > 2.0). We present spectral templates for identification and redshift estimation of quasars in the DESI Year 1 data release. The quasar templates are comprised of two quasar eigenspectra sets, trained on spectra from the Sloan Digital Sky Survey. The sets are specialized to reconstruct quasar spectral variation observed over separate yet overlapping redshift ranges and, together, are capable of identifying DESI quasars from 0.05 < z < 7.0. The new quasar templates show significant improvement over the previous DESI quasar templates regarding catastrophic failure rates, redshift precision and accuracy, quasar completeness, and the contamination fraction in the final quasar sample.

79 ASTRONOMY AND ASTROPHYSICS↗

Preliminary Target Selection for the DESI Luminous Red Galaxy (LRG) Sample

The DESI survey will observe more than 8 million candidate luminous red galaxies (LRGs) in the redshift range 0.3 < z < 1.0. In this work, we present a preliminary version of the DESI LRG target section developed using Legacy Surveys Data Release 8 g, r, z and W1 photometry. This selection yields a sample with a uniform surface density of ~600 deg –2 and very low predicted stellar contamination and redshift failure rates. During DESI Survey Validation, updated versions of this selection will be tested and optimized.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of cloud height, optical thickness, and phase retrievals from the CHROMA algorithm applied to Sentinel-3 OLCI data

We previously developed the Cloud Height Retrieval from O 2 Molecular Absorption (CHROMA) algorithm for the Ocean Color Instrument (OCI) on the new NASA Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission. Here, we apply CHROMA to observations from the Ocean Land Colour Instrument (OLCI) to guide expectations for PACE, as it will take some time to obtain large-scale validation data for OCI. We use cloud top height (CTH), phase, and (for liquid clouds) cloud optical thickness (COT) data from the ground-based Atmospheric Radiation Measurement (ARM) network to evaluate the OLCI retrievals. We found that OLCI and Moderate Resolution Imaging Spectroradiometer (MODIS) CTH compare similarly well to the ARM reference. OLCI has a tendency to underestimate CTH as CTH increases, and algorithm assumptions about cloud geometric thickness may contribute to this. ARM COT from multifilter shadowband radiometers (MFRSR) and Sun photometers are well-correlated with one another, albeit with a roughly 30 % offset on average; OLCI and MODIS COT agree more closely with the MFRSR data. OLCI retrieval uncertainty estimates show skill at telling low-uncertainty cases from high-uncertainty ones, although CTH uncertainties are underestimated. Additionally, we compare the OLCI data to satellite retrievals based on thermal infrared measurements from MODIS and Sea and Land Surface Temperature Radiometer (SLSTR) data. Differences are broadly consistent with physical expectations based on the A-band vs. thermal techniques, although one key challenge in such aggregated comparisons is different cloud masking sensitivities and algorithm failure rates meaning additional sampling differences are introduced. We conclude by discussing the transition to and possible enhancements for PACE OCI.

Sayer, Andrew M. [Univ. of Maryland Baltimore Coun↗

Development of reliability prediction technique for semiconductor diodes

New fundamental technique of reliability prediction for semiconductor diodes based on realistic mathematical models can be applied to component failure rate prediction including mechanical degradation, electrical degradation, environmental stress factors, and electrical load stress factors.

Ryerson, C. M.↗