At least 289 records · Page 16

The calibration of carbon nanotube based bionanosensors

We derive the calibration constants necessary for using single-walled carbon nanotubes (CNTs) as nanoscale mass sensors. The CNT resonators are assumed to be either in cantilevered or in bridged configurations. Two cases, namely, when the added mass can be considered as a point mass and when the added mass is distributed over a larger area is considered. Closed-form transcendental equations have been derived for the frequency shift due to the added mass. Using the energy principles, generalized nondimensional calibration constants have been derived for an explicit relationship between the added mass and the frequency shift. A molecular mechanics model based on the universal force field potential is used to validate the new results presented. The results indicate that the distributed nature of the mass to be detected has considerable effect on the performance of the sensor.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

SOLAR FLOWS AND THEIR EFFECT ON FREQUENCIES OF ACOUSTIC MODES

We have calculated the effects of large-scale solar flows, such as the meridional circulation, giant convection cells, and solar rotation on the helioseismic splitting coefficients using quasi-degenerate perturbation theory (QDPT). Our investigation reveals that the effect of poloidal flows like the large-scale meridional circulation are difficult to detect in observational data of the global acoustic modes since the frequency shifts are much less than the errors. However, signatures of large-scale convective flows may be detected if their amplitude is sufficiently large by looking for frequency shifts due to nearly degenerate modes coupled by convection. In this comprehensive study, we attempt to put limits on the magnitude of flow velocities in giant cells by comparing the splitting coefficients obtained from the QDPT treatment with observational data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Method and apparatus for measuring frequency and phase difference

The present invention is a system for deriving direct digital indications of frequency and phase difference between two incoming pulse trains adaptable for collision avoidance systems or the like. A pair of radar beams are directed toward a target and corresponding beams returning therefrom are detected. A digital difference circuit forms a pulse train from the Doppler shift frequencies of each beam pair having a repetition rate functionally related to the difference in magnitude of the shift frequencies. Pulses from the pulse train are counted as a function of time. Visual indications thereof on display are correlative to target position relative to beams.

Shores, Paul↗

Robust Vector BOTDA Signal Processing with Probabilistic Machine Learning

This paper presents a novel probabilistic machine learning (PML) framework to estimate the Brillouin frequency shift (BFS) from both Brillouin gain and phase spectra of a vector Brillouin optical time-domain analysis (VBOTDA). The PML framework is used to predict the Brillouin frequency shift (BFS) along the fiber and to assess its predictive uncertainty. We compare the predictions obtained from the proposed PML model with a conventional curve fitting method and evaluate the BFS uncertainty and data processing time for both methods. The proposed method is demonstrated using two BOTDA systems: (i) a BOTDA system with a 10 km sensing fiber and (ii) a vector BOTDA with a 25 km sensing fiber. The PML framework provides a pathway to enhance the VBOTDA system performance.

47 OTHER INSTRUMENTATION↗

Doppler Lidar (DL) Instrument Handbook

The Doppler lidar (DL) is an active remote sensing instrument that provides range- and time-resolved measurements of radial velocity and attenuated backscatter. The principle of operation is similar to radar in that pulses of energy are transmitted into the atmosphere; the energy scattered back to the transceiver is collected and measured as a time-resolved signal. From the time delay between each outgoing transmitted pulse and the backscattered signal, the distance to the scatterer is inferred. The radial or line-of-sight velocity of the scatterers is determined from the Doppler frequency shift of the backscattered radiation. The DL uses a heterodyne detection technique in which the return signal is mixed with a reference laser beam (i.e., local oscillator) of known frequency. An onboard signal processing computer then determines the Doppler frequency shift from the spectra of the heterodyne signal. The energy content of the Doppler spectra can also be used to determine attenuated backscatter.

99 GENERAL AND MISCELLANEOUS↗

Nonlinear frequency up-conversion of femtosecond pulses from an erbium fibre laser to the range of 0.8 - 1 {mu}m in silica fibres

We consider different mechanisms of nonlinear frequency up-conversion of femtosecond pulses emitted by an erbium fibre system ({lambda} = 1.5 {mu}m) to the range of 0.8 - 1.2 {mu}m in nonlinear silica fibres. The generation efficiency and the centre frequencies of dispersive waves are found as functions of the parameters of the fibre and the input pulse. Simple analytical estimates are obtained for the spectral distribution of the intensity and the frequency shift of a wave packet in the region of normal dispersion during the emission of a high-order soliton under phase matching conditions. In the geometrical optics approximation the frequency shifts are estimated in the interaction of dispersive waves with solitons in various regimes. (extreme light fields and their applications)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quartz Crystal Microbalance (QCM) monitor of contamination for LES-8/9

A Quartz Crystal Microbalance (QCM) was used to monitor condensable contamination during the launching of two Lincoln Laboratory Experimental Satellites--LES-8 and LES-9. The QCM was installed on the dispenser truss and measured contamination by means of a frequency shift of a quartz crystal oscillator. By using a special crystal cut and a second reference quartz crystal, the sensor had extreme sensitivity and remarkable temperature independence. A 1-Hz frequency shift, which corresponds to 3.5 x 10 to the -9th power g/sq cm was resolved by the flight instrumentation.

Lynch, J. T.↗

Microcantilever-based gas sensor employing two simultaneous physical sensing modes

According to one embodiment, a system for detecting and identifying gases includes a piezoresistive microcantilever transducer, wherein dissipation of heat from the piezoresistive microcantilever into one or more gases is measured by changes in an electrical resistance of the piezoresistor, a vibrating microcantilever transducer, wherein shifts are measured in resonant frequency of the vibrating microcantilever due to viscous damping thereof by the one or more gases, and a subsystem for correlating the measured resistance changes and the resonant frequency shifts to the one or more gases. In another embodiment, a method for detecting and identifying one or more gases includes determining dissipation of heat from a microcantilever into one or more gases, and determining shifts in resonant frequency of the microcantilever due to viscous damping thereof by the one or more gases. Other systems, methods, and computer program products are also described according to more embodiments.

47 OTHER INSTRUMENTATION↗

Method and apparatus for measuring frequency and phase difference

A system for deriving direct digital indications of frequency and phase difference between two incoming pulse trains adaptable for collision avoidance systems or the like. A pair of radar beams 152 and 152A are directed toward a target 153 and corresponding beams 154 and 154A returning therefrom are detected. A digital difference circuit 110 forms a pulse train 66 from the Doppler shift frequencies of each beam pair having a repetition rate functionally related to the difference in magnitude of the shift frequencies. Pulses from the pulse train are counted as a function of time. Visual indications thereof on display 144 are correlative to target position relative to beams 152 and 152A.

Kobayashi, Herbert S.↗

Short-term changes in solar oscillation frequencies and solar activity

It is shown that the frequencies of solar rho-mode oscillations change significantly over periods as short as one month. These changes correlate significantly with variations in the strength of surface solar activity as measured by the average, over the sun's visible surface, of the magnitude of the line-of-sight magnetic field component from magnetograms. The frequency and mean magnetic variations are found to obey a linear relationship. It is seen that the mean frequency shift at any time depends on the history of solar activity over an interval of, at most, several months prior to the measurement and conclude that the dominant mechanism of the frequency shift is correlated with surface magnetic activity.

Woodard, M. F.↗

High-fidelity imaging of a band insulator in a three-dimensional optical lattice clock

Here, we report on the observation of a high-density, band insulating state in a three-dimensional optical lattice clock. Filled with a nuclear-spin-polarized degenerate Fermi gas of 87 Sr, the three-dimensional (3D) lattice has one atom per site in the ground motional state, thus guarding against frequency shifts due to contact interactions. At this high density where the average distance between atoms is comparable to the probe wavelength, conventional imaging techniques at saturation intensity suffer from large systematic errors. To spatially probe frequency shifts in the clock and measure thermodynamic properties of this system, accurate imaging techniques at high optical depths are required. Using a combination of highly saturated fluorescence and absorption imaging, we confirm the density distribution in our 3D optical lattice in agreement with a single spin band insulating state. Combining our clock platform with this high filling fraction opens the door to studying new classes of long-lived, many-body states arising from dipolar interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Formulation and Comparison of Two Real-Time Predictive Gear Shift Algorithms for Connected/Automated Heavy-Duty Vehicles

Our work investigates the problem of predictive gear scheduling for fuel consumption minimization in connected/automated heavy trucks. The literature highlights the fuel economy benefits of such predictive scheduling, but there is a need to optimize such scheduling online, in real time. To address this need, we begin by using dynamic programming (DP) to schedule gear shifting offline, in a manner that achieves a globally optimal Pareto tradeoff between the conflicting objectives of minimizing fuel consumption and shift frequency. The computational cost of DP is unfavorable for online implementation, but we present two algorithms addressing this issue. Both algorithms rely on the fact that in the Pareto limit where fuel consumption minimization is the sole objective, DP furnishes a simple static shift map . Our first algorithm trains a recurrent neural network to prune the shift schedule generated by this map. The second algorithm performs this pruning in a direct manner tailored to reduce the schedule's rain flow count. We simulate these algorithms for different drive cycles. Both algorithms achieve a reasonable tradeoff between fuel consumption and gear shift frequency. Yet, the rain flow count algorithm is both more effective in approaching the DP-based Pareto front and more computationally efficient.

33 ADVANCED PROPULSION SYSTEMS↗

A Technique for Adjusting Eigenfrequencies of WGM Resonators

A simple technique has been devised for making small, permanent changes in the eigenfrequencies (resonance frequencies) of whispering-gallery-mode (WGM) dielectric optical resonators that have high values of the resonance quality factor (Q). The essence of the technique is to coat the resonator with a thin layer of a transparent polymer having an index of refraction close to that of the resonator material. Successive small frequency adjustments can be made by applying successive coats. The technique was demonstrated on a calcium fluoride resonator to which successive coats of a polymer were applied by use of a hand-made wooden brush. To prevent temperature- related frequency shifts that could interfere with the verification of the effectiveness of this technique, the temperature of the resonator was stabilized by means of a three-stage thermoelectric cooler. Measurements of the resonator spectrum showed the frequency shifts caused by the successive coating layers.

Strekalov, Dmitry↗

Research and Development of Non-Spectroscopic MEMS-Based Sensor Arrays for Targeted Gas Detection

In this report, we present our progress during Fiscal Year 2012 (FY12) in the research and development of a non-spectroscopic method for noble gas detection. During Fiscal Year 2011 (FY11), we demonstrated that coating-free damped resonance detection (cfDRD) could be used for the selective sensing of pure gases and simple (binary) admixtures. Specifically, it was found that a sensor response signature comprised of both resonant peak shape change and frequency shift data exhibited increased chemical selectivity over a response signature based only on the latter contribution. The sensor response signature is presently comprised of three distinct data inputs: two channels from the cfDRD sensor component [shape change (attenuation/amplification), frequency shift], and one from a thermal conductivity detection (TCD) sensor component. A single commercial-off-the-shelf (COTS) resonator (Bruker Active Probe microcantilever) was excited into either its 1 st or 4 th resonant modes, where it was found that the latter was apparently insensitive to compositional changes in the surrounding gas; this difference was attributed to the ~20x difference in average flexural displacement in the former versus the latter, and the expected dominance of inertial effects in the damping phenomenon.

42 ENGINEERING↗

Compression and Probing C−H···I Hydrogen Bonds of Iodoform under High Pressure by X-ray Diffraction and Raman Scattering

High-pressure methods were applied to investigate the structural stability and hydrogen bonding of polar molecules of iodoform by synchrotron radiation X-ray diffraction and Raman spectra measurements, respectively. Up to a pressure of 40 GPa, no phase transitions were observed. The discontinuous frequency shift of the C-H stretching band is believed to be related to the enhancement of the C-H{hor_ellipsis}I weak hydrogen bonds under high pressures. Ab initio calculations were performed, and the results predict the frequency shift of the C-H stretching vibration as C-H{hor_ellipsis}I interacts via hydrogen bonding. The bulk modulus is 17.3 {+-} 0.8 GPa, with a pressure derivative of 5.2.

08 HYDROGEN↗

Method and System for Producing Images of an Object

A method and system are provided to produce images of an object. A receiving station is positioned in view of a range-coded signal emitting satellite and the object. The receiving station is sensitive to direct transmission of the range-coded signal and reflections of the range-coded signal from the object. Both range from the receiving station to the object and a Doppler frequency shift history between the receiving station and the object is determined using the direct transmission and reflections of the range-coded signal. An image is formed using the two-dimensional record provided by the range and the Doppler frequency shift history.

Katzberg, Stephen J.↗

Radiometric Spacecraft Tracking for Deep Space Navigation

Interplanetary spacecraft navigation relies on three types of terrestrial tracking observables.1) Ranging measures the distance between the observing site and the probe. 2) The line-of-sight velocity of the probe is inferred from Doppler-shift by measuring the frequency shift of the received signal with respect to the unshifted frequency. 3) Differential angular coordinates of the probe with respect to natural radio sources are nominally obtained via a differential delay technique of (Delta) DOR (Delta Differential One-way Ranging). The accuracy of spacecraft coordinate determination depends on the measurement uncertainties associated with each of these three techniques. We evaluate the corresponding sources of error and present a detailed error budget.

ranging↗