Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FINGERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Evaluation of two-phase relative permeability and capillary pressure relations for unstable displacements in a pore network

A series of displacement experiments was conducted using five wetting-nonwetting immiscible fluid pairs in a homogenous and uniform pore network. The micromodel was initially saturated with either polyethylene glycol 200 (PEG) or water as a wetting fluid, which was subsequently displaced by a nonwetting fluid (dodecane, hexadecane, or mineral oil) at different flow rates. The experiments were designed to allow determinations of nonwetting fluid relative permeabilities ( ), fluid saturations ( ), and capillary pressure heads ( ). In the displacements, nonwetting fluid saturations increased with increasing flow rates for all five fluid pairs, and viscous fingering, capillary fingering, and stable displacement were observed. Viscous fingering occurred when PEG was displaced by either dodecane or hexadecane. For the water displacements, capillary fingers were observed at low capillary numbers. Due to unstable fingering phenomena, values for the PEG displacements were smaller than for the water displacements. A fitting exercise using the Brooks-Corey (1964) relationship showed that the fitted entry pressure heads are reasonably close to the computed entry pressure head. The fitted pore geometry factor, S n values for the displacements are considerably lower than what is expected for displacements in homogeneous, highly uniform, porous systems, demonstrating the impact of unstable displacement on the apparent value of S n . It was shown that a continuum-based multiphase model could be used to predict the average behavior for wetting fluid drainage in a pore network as long as independently fitted - and - relations are used. The use of a coupled approach through the Brooks-Corey pore geometry factor underpredicts observed values.

36 MATERIALS SCIENCE↗

Simulation of Coupled Processes of Flow, Transport, and Storage of CO 2 in Saline Aquifers

This report is the final scientific one for the award DE- FE0000988 entitled “Simulation of Coupled Processes of Flow, Transport, and Storage of CO 2 in Saline Aquifers.” The work has been divided into six tasks. In task, “Development of a Three-Phase Non-Isothermal CO 2 Flow Module,” we developed a fluid property module for brine-CO 2 mixtures designed to handle all possible phase combinations of aqueous phase, sub-critical liquid and gaseous CO 2 , supercritical CO 2 , and solid salt. The thermodynamic and thermophysical properties of brine-CO 2 mixtures (density, viscosity, and specific enthalpy of fluid phases; partitioning of mass components among the different phases) use the same correlations as an earlier fluid property module that does not distinguish between gaseous and liquid CO 2 -rich phases. We verified the fluid property module using two leakage scenarios, one that involves CO 2 migration up a blind fault and subsequent accumulation in a secondary “parasitic” reservoir at shallower depth, and another investigating leakage of CO 2 from a deep storage reservoir along a vertical fault zone. In task, “Development of a Rock Mechanical Module,” we developed a massively parallel reservoir simulator for modeling THM processes in porous media brine aquifers. We derived, from the fundamental equations describing deformation of porous elastic media, a momentum conservation equation relating mean stress, pressure, and temperature, and incorporated it alongside the mass and energy conservation equations from the TOUGH2 formulation, the starting point for the simulator. In addition, rock properties, namely permeability and porosity, are functions of effective stress and other variables that are obtained from the literature. We verified the simulator formulation and numerical implementation using analytical solutions and example problems from the literature. For the former, we matched a one-dimensional consolidation problem and a two-dimensional simulation of the Mandel-Cryer effect. For the latter, we obtained a good match of temperature and gas saturation profiles, and surface uplift, after injection of hot fluid into a model of a caldera structure. In task, “Incorporation of Geochemical Reactions of Selected Important Species,” we developed a novel mathematical model of THMC processes in porous and fractured saline aquifers, simulating geo-chemical reactions associated with CO 2 sequestration in saline aquifers. Two computational frameworks, sequentially coupled and fully coupled, were used to simulate the reactions and transport. We verified capabilities of the THMC model to treat complex THMC processes during CO 2 sequestration by analytical solutions and we constructed reactive transport models to analyze the THMC process quantitatively. Three of these are 1D reactive transport under chemical equilibrium, a batch reaction model with equilibrium chemical reactions, and a THMC model with CO 2 dissolution. In task “Study of Instability in CO 2 Dissolution-Diffusion-Convection Processes,” We reviewed literature related to the study of density driven convective flows and on the instability of CO 2 dissolution-diffusion-convection processes. We ran simulations that model the density-driven flow instability that would occur during CO 2 sequestration. CO 2 diffused through the top of the system and dissolved in the aqueous phase there, increasing its density. Density fingers formed along the top boundary, and coalesced into a few prominent ones, causing convective flow that forced the fluid to the system bottom. These simulations were in two and three dimensions. We ran additional simulations of convective mixing with density contrast caused by variable dissolved CO 2 concentration in saline water, modeled after laboratory experiments in which supercritical CO2 was circulated in the headspace above a brine saturated packed sand in a pressure vessel. As CO 2 dissolved into the upper part of the saturated sand, liquid phase density increases causing instability and setting off convective mixing. We obtained good agreement with the laboratory experiments, which were characterized by finger development and associated mixing of dissolved CO 2 into the system. We then varied a wide range of parameters and conceptual models in order to analyze the possibility of convective mixing under different conditions, such as various boundary conditions, and chemical reaction conditions. The CO 2 fingers from different simulations showed great differences as time progressed, caused by permeability heterogeneity. The early time diffusive phenomenon was captured by fine grid resolution, and the permeability heterogeneity affected the pattern of the CO 2 fingers. In addition, the fingers from three-dimensional simulations tended to be larger and flatter than the two-dimensional ones. In task “Implementation of Efficient Parallel Computing Technologies,” we made enhancements and modifications to our code in order to substantially increase the grid size that could be run. We installed and ran it on various platforms, including a multi-core PC and a cluster, and verified the numerical implementation and parallel code using an example problem from the literature. This problem, with a grid size of sixty million, utilized the cluster’s entire memory and all of its processors. In task “Implementation of General Fracture Conceptual Models,” we used the MINC approach, a generalization of the double-porosity concept, to model flow through porous and fractured media. In this approach, flow within the matrix is described by subdividing the matrix into nested volumes, with flow occurring between adjacent nested matrix volumes as well as between the fractures and the outer matrix volume. We generalized Hooke’s law to a thermo-multi- poroelastic medium, and derived from the fundamental equations describing deformation of porous and fractured elastic media a momentum conservation equation for thermo-multi- poroelastic media. This equation is a generalization to multi-poroelastic media of the one derived in Task 3.0 for single porosity media. We describe two simulations to provide model verification and application examples. The first, one-dimensional consolidation of a double-porosity medium, is compared to an analytical solution. The second is a match of published results from the literature, a simulation of CO 2 injection into hypothetical aquifer-caprock systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

EVA space suit Evaporative Cooling/Heating Glove System (ECHGS)

A new astronaut glove, the Evaporative Cooling/Heating Glove System (ECHGS), was designed and developed to allow the handling of objects between -200 F and +200 F. Active heating elements, positioned at each finger pad, provide additional heat to the finger pads from the rest of the finger. A water evaporative cooling system provides cooling by the injection of water to the finger areas and the subsequent direct evaporation to space. Thin, flexible insulation has been developed for the finger areas to limit thermal conductivity. Component and full glove tests have shown that the glove meets and exceeds the requirements to hold a 11/2 inch diameter bar at + or - 200 F for three minutes within comfort limits. The ECHGS is flexible, lightweight and comfortable. Tactility is reasonable and small objects can be identified especially by the fingertips beyond the one half width active elements.

Coss, F. A.↗

Orbital maneuvering end effectors

This invention relates to an end effector device for grasping and maneuvering objects such as berthing handles of a space telescope. The device includes a V-shaped capture window defined as inclined surfaces in parallel face plates which converge toward a retainer recess in which the handle is retained. A pivotal finger (30) meshes with a pair of pivoted fingers which rotate in counterrotation. The fingers rotate to pull a handle within the capture window into recess where latches lock handle in the recess. To align the capture window, plates may be cocked plus or minus five degrees on base. Drive means is included in the form of a motor coupled with a harmonic drive speed reducer, which provides for slow movement of the fingers at a high torque so that large articles may be handled. Novelty of the invention is believed to reside in the combined intermeshing finger structure, drive means and the harmonic drive speed reducer, which features provide the required maneuverability and strength.

Myers, W. Neill↗

Wire perturbations in the Staffman-Taylor problem

Zocchi et al. (1987) discovered that when two wires are symmetrically placed along the center of a Hele-Shaw cell, symmetric but narrow fingers of dimensionless width lambda less than 0.5 develop. The value of lambda decreases as the pushing velocity increases, but at a certain critical finger width the finger suddenly undergoes a transition to the asymmetrical state. A simple theory to predict this critical finger width as a function of D, the dimensionless distance between two wires is developed by assuming that the finger opens up a negative angle at the contact point.

Hong, D. C.↗

Passively activated prehensile digit for a robotic end effector

A common hydraulic reservoir holds one or more rows of slidable pistons or fingers in a base or hand. The individual fingers in each row expose graduated cross sectional fluid application areas to the hydraulic fluid in the reservoir, with the smallest fluid application area in the center of the row and graduating to progressive larger fluid areas towards both ends of each row. The fingers are elongated pistons. Exposed outer ends of each piston extending away from the reservoir, house a transverse pad to contact an object to be held. The transverse pads are universally ball-joint and spring-center mounted in a longitudinally located opening at the outer tapered end of each finger. Simple and effective capacitance metering in the reservoir is provided for each finger.

Earl R Collins, Jr↗

Concept for a large master/slave-controlled robotic hand

A strategy is presented for the design and construction of a large master/slave-controlled, five-finger robotic hand. Each of the five fingers will possess four independent axes each driven by a brushless DC servomotor and, thus, four degrees-of-freedom. It is proposed that commercially available components be utilized as much as possible to fabricate a working laboratory model of the device with an anticipated overall length of two-to-four feet (0.6 to 1.2 m). The fingers are to be designed so that proximity, tactile, or force/torque sensors can be imbedded in their structure. In order to provide for the simultaneous control of the twenty independent hand joints, a multilevel master/slave control strategy is proposed in which the operator wears a specially instrumented glove which produces control signals corresponding to the finger configurations and which is capable of conveying sensor feedback signals to the operator. Two dexterous hand master devices are currently commercially available for this application with both undergoing continuing development. A third approach to be investigated for the master control mode is the use of real-time image processing of a specially patterned master glove to provide the respective control signals for positioning the multiple finger joints.

Grissom, William A.↗

A study of space-rated connectors using a robotic end-effector

The fabrication and testing of a pair of robot fingers designed to grasp two types of Orbital Replacement Unit (ORU) interfaces, the H Handle type and the Micro Square type are discussed. A closed-form solution is given for the force inverse kinematics. A numerical solution using the Newton-Raphson Method for force forward kinematics is given. Mathematical expressions are derived to compute forces/torques applied to the finger. Suggestions are given for improving finger fabrication. The results of numerous experiments conducted to study the characteristics and feasibility of the fingers are given. The first part of the study was devoted to obtaining data on the forces applied by the finger to the interfaces under various translational and rotational misalignments; the second part was devoted to determining the maximum allowed capture angles that would insure successful mating; and the third part was devoted to the processing and interpretation of the forces/torque data.

Nguyen, Charles C.↗

Rotationally actuated prosthetic helping hand

A prosthetic device has been developed for below-the-elbow amputees. The device consists of a cuff, a stem, a housing, two hook-like fingers, an elastic band for holding the fingers together, and a brace. The fingers are pivotally mounted on a housing that is secured to the amputee's upper arm with the brace. The stem, which also contains a cam, is rotationally mounted within the housing and is secured to the cuff, which fits over the amputee's stump. By rotating the cammed stem between the fingers with the lower arm, the amputee can open and close the fingers.

Norton, William E.↗

Fine manipulation with multifinger hands

The existence of two- and three-finger grasps in the presence of arbitrarily small friction is shown for two- and three-dimensional smooth objects using a simple technique. No convexity of the objects is assumed. The existence of finger gaits for rotating a planar object using three and four fingers is proved. Additional results for smooth convex objects which describe two different finger gaits using four fingers are presented.

Hong, J.↗

Preloaded latching device

A latching device is disclosed which is lever operated sequentially to actuate a set of collet fingers to provide a radial expansion and to actuate a force mechanism to provide a compressive gripping force for attaching first and second devices to one another. The latching device includes a body member having elongated collet fingers which, in a deactuated condition, is insertable through bores on the first and second devices so that gripping terminal portions on the collet fingers are proximate to the end of the bore of the first device while a spring assembly on the body member is located proximate to the outer surface of a second device. A lever is rotatable through 90 deg to move a latching rod to sequentially actuate and expand collet fingers and to actuate the spring assembly by compressing it. During the first 30 deg of movement of the lever, the collet fingers are actuated by the latching rod to provide a radial expansion and during the last 60 deg of movement of the lever, the spring assembly acts as a force mechanism and is actuated to develop a compressive latching force on the devices. The latching rod and lever are connected by a camming mechanism. The amount of spring force in the spring assembly can be adjusted; the body member can be permanently attached by a telescoping assembly to one of the devices; and the structure can be used as a pulling device for removing annular bearings or the like from blind bores.

Wesselski, Clarence J.↗

Numerical simulation of torus-driven plasma transport in the Jovian magnetosphere

The Rice convection model has been modified for application to the transport of Io-generated plasma through the Jovian magnetosphere. The new code, called the RCM-J, has been used for several ideal-magnetohydrodynamic (MHD) numerical simulations to study how interchange instability causes an initially assumed torus configuration to break up. In simulations that start from a realistic torus configuration but include no energetic particles, the torus disintegrates too quickly (approximately 50 hours). By adding an impounding distribution of energetic particles to suppress the interchange instability, resonable lifetimes were obtained. For cases in which impoundment is insufficient to produce ideal-MHD stability, the torus breaks up predominantly into long fingers, unless the initial condition strongly favors some other geometrical form. If the initial torus has more mass on one side of the planet than the other, fingers form predominatly on the heavy side (which we associate with the active sector). Coriolis force bends the fingers to lag corotation. The simulation results are consistent with the idea that the fingers are formed with a longitudinal thickness that is roughly equal to the latitudinal distance over which the invariant density declines at the outer edges of the initial torus. Our calculations give an average longitudinal distance between plasma fingers of about 15 deg which corresponds to 20 to 30 minutes of rotation of the torus. We point to some Voyager and Ulysses data that are consistent with this scale of torus longitudinal irregularity.

Yang, Y. S.↗

Long-Term Reliability of High Speed SiGe/Si Heterojunction Bipolar Transistors

Accelerated lifetime tests were performed on double-mesa structure Si/Si0.7Ge0.3/Si npn heterojunction bipolar transistors, grown by molecular beam epitaxy, in the temperature range of 175C-275C. Both single- and multiple finger transistors were tested. The single-finger transistors (with 5x20 micron sq m emitter area) have DC current gains approximately 40-50 and f(sub T) and f(sub MAX) of up to 22 GHz and 25 GHz, respectively. The multiple finger transistors (1.4 micron finger width, 9 emitter fingers with total emitter area of 403 micron sq m) have similar DC current gain but f(sub T) of 50 GHz. It is found that a gradual degradation in these devices is caused by the recombination enhanced impurity diffusion (REID) of boron atoms from the p-type base region and the associated formation of parasitic energy barriers to electron transport from the emitter to collector layers. This REID has been quantitatively modeled and explained, to the first order of approximation, and the agreement with the measured data is good. The mean time to failure (MTTF) of the devices at room temperature is estimated from the extrapolation of the Arrhenius plots of device lifetime versus reciprocal temperature. The results of the reliability tests offer valuable feedback for SiGe heterostructure design in order to improve the long-term reliability of the devices and circuits made with them. Hot electron induced degradation of the base-emitter junction was also observed during the accelerated lifetime testing. In order to improve the HBT reliability endangered by the hot electrons, deuterium sintered techniques have been proposed. The preliminary results from this study show that a deuterium-sintered HBT is, indeed, more resistant to hot-electron induced base-emitter junction degradation. SiGe/Si based amplifier circuits were also subjected to lifetime testing and we extrapolate MTTF is approximately 1.1_10(exp 6) hours at 125iC junction temperature from the circuit lifetime data.

Ponchak, George E.↗

Compression under a mechanical counter pressure space suit glove

Background: Current gas-pressurized space suits are bulky stiff shells severely limiting astronaut function and capability. A mechanical counter pressure (MCP) space suit in the form of a tight elastic garment could dramatically improve extravehicular activity (EVA) dexterity, but also be advantageous in safety, cost, mass and volume. The purpose of this study was to verify that a prototype MCP glove exerts the design compression of 200 mmHg, a pressure similar to the current NASA EVA suit. Methods: Seven male subjects donned a pressure measurement array and MCP glove on the right hand, which was placed into a partial vacuum chamber. Average compression was recorded on the palm, the bottom of the middle finger, the top of the middle finger and the dorsum of the hand at pressures of 760 (ambient), 660 and 580 mmHg. The vacuum chamber was used to simulate the pressure difference between the low breathing pressure of the current NASA space suits (approximately 200 mmHg) and an unprotected hand in space. Results: At ambient conditions, the MCP glove compressed the dorsum of the hand at 203.5 +/- 22.7 mmHg, the bottom of the middle finger at 179.4 +/- 16.0 mmHg, and the top of the middle finger at 183.8 +/- 22.6 mmHg. The palm compression was significantly lower (59.6 +/- 18.8 mmHg, p<0.001). There was no significant change in glove compression with the chamber pressure reductions. Conclusions: The MCP glove compressed the dorsum of the hand and middle finger at the design pressure.

NASA Discipline Life Sciences Technologies↗

Coordinated turn-and-reach movements. I. Anticipatory compensation for self-generated coriolis and interaction torques

When reaching movements involve simultaneous trunk rotation, additional interaction torques are generated on the arm that are absent when the trunk is stable. To explore whether the CNS compensates for such self-generated interaction torques, we recorded hand trajectories in reaching tasks involving various amplitudes and velocities of arm extension and trunk rotation. Subjects pointed to three targets on a surface slightly above waist level. Two of the target locations were chosen so that a similar arm configuration relative to the trunk would be required for reaching to them, one of these targets requiring substantial trunk rotation, the other very little. Significant trunk rotation was necessary to reach the third target, but the arm's radial distance to the body remained virtually unchanged. Subjects reached at two speeds-a natural pace (slow) and rapidly (fast)-under normal lighting and in total darkness. Trunk angular velocity and finger velocity relative to the trunk were higher in the fast conditions but were not affected by the presence or absence of vision. Peak trunk velocity increased with increasing trunk rotation up to a maximum of 200 degrees /s. In slow movements, peak finger velocity relative to the trunk was smaller when trunk rotation was necessary to reach the targets. In fast movements, peak finger velocity was approximately 1.7 m/s for all targets. Finger trajectories were more curved when reaching movements involved substantial trunk rotation; however, the terminal errors and the maximal deviation of the trajectory from a straight line were comparable in slow and fast movements. This pattern indicates that the larger Coriolis, centripetal, and inertial interaction torques generated during rapid reaches were compensated by additional joint torques. Trajectory characteristics did not vary with the presence or absence of vision, indicating that visual feedback was unnecessary for anticipatory compensations. In all reaches involving trunk rotation, the finger movement generally occurred entirely during the trunk movement, indicating that the CNS did not minimize Coriolis forces incumbent on trunk rotation by sequencing the arm and trunk motions into a turn followed by a reach. A simplified model of the arm/trunk system revealed that additional interaction torques generated on the arm during voluntary turning and reaching were equivalent to < or =1.8 g (1 g = 9.81 m/s(2)) of external force at the elbow but did not degrade performance. In slow-rotation room studies involving reaching movements during passive rotation, Coriolis forces as small as 0.2 g greatly deflect movement trajectories and endpoints. We conclude that compensatory motor innervations are engaged in a predictive fashion to counteract impending self-generated interaction torques during voluntary reaching movements.

NASA Discipline Neuroscience↗

Haptic stabilization of posture: changes in arm proprioception and cutaneous feedback for different arm orientations

Postural sway during quiet stance is attenuated by actively maintained contact of the index finger with a stationary surface, even if the level of applied force (<1 N) cannot provide mechanical stabilization. In this situation, changes in force level at the fingertip lead changes in center of foot pressure by approximately 250 ms. These and related findings indicate that stimulation of the fingertip combined with proprioceptive information about the hand and arm can serve as an active sensor of body position relative to the point of contact. A geometric analysis of the relationship between hand and torso displacement during body sway led to the prediction that arm and hand proprioceptive and finger somatosensory information about body sway would be maximized with finger contact in the plane of body sway. Therefore, the most postural stabilization should be possible with such contact. To test this analysis, subjects touched a laterally versus anteriorly placed surface while in each of two stances: the heel-to-toe tandem Romberg stance that reduces medial-lateral stability and the heel-to-heel, toes-outward, knees-bent, "duck stance" that reduces fore-aft stability. Postural sway was always least with finger contact in the unstable plane: for the tandem stance, lateral fingertip contact was significantly more effective than frontal contact, and, for the duck stance, frontal contact was more effective than lateral fingertip contact. Force changes at the fingertip led changes in center of pressure of the feet by approximately 250 ms for both fingertip contact locations for both test stances. These results support the geometric analysis, which showed that 1) arm joint angles change by the largest amount when fingertip contact is maintained in the plane of greatest sway, and 2) the somatosensory cues at the fingertip provide both direction and amplitude information about sway when the finger is contacting a surface in the unstable plane.

Non-NASA Center↗

Novel Shapes of Miscible Interfaces Observed

The dynamics of miscible displacements in a cylindrical tube are being investigated experimentally and numerically, with a view to understand the complex processes that occur, for example, in enhanced oil recovery, hydrology, and filtration. We have observed complex shapes of the interface between two liquids that mix with each other when the less viscous liquid is displaced by the more viscous one in a tube. A less viscous fluid that displaces a more viscous fluid is known to propagate in the form of a "finger," and a flight experiment proposed by Maxworthy et al. to investigate the miscible-interface dynamics is currently being developed by NASA. From the current theory of miscible displacements, which was developed for a porous medium satisfying Darcy's law, it can be shown that in the absence of gravity the interface between the fluids is destabilized and thus susceptible to fingering only when a more viscous fluid is displaced by a less viscous one. Therefore, if the interface is initially flat and the more viscous fluid displaces the less viscous fluid, the interface ought to be stable and remain flat. However, numerical simulations by Chen and Meiburg for such displacement in a cylindrical tube show that the interface is unstable and a finger of the more viscous fluid is indeed formed. Preliminary experiments performed at the NASA Glenn Research Center show that not only can fingering occur when the more viscous fluid displaces a less viscous one in a cylindrical tube, but also that under certain conditions the advancing finger achieves a sinuous or snakelike shape. These experiments were performed using silicone oils in a vertical pipette of small diameter. In the initial configuration, the more viscous fluid rested on top of the less viscous one, and the interface was nominally flat. A dye was added to the upper liquid for ease of observation of the interface between the fluids. The flow was initiated by draining the lower fluid from the bottom of the pipette, at speeds less than 0.1 mm/sec.

Balasubramaniam, Ramaswamy↗

Development and Test of Robotically Assisted Extravehicular Activity Gloves

Over the past two years, the High Performance EVA Glove (HPEG) project under NASA's Space Technology Mission Directorate (STMD) funded an effort to develop an electromechanically-assisted space suit glove. The project was a collaboration between the Johnson Space Center's Software, Robotics, and Simulation Division and the Crew and Thermal Systems division. The project sought to combine finger actuator technology developed for Robonaut 2 with the softgoods from the ILC Phase VI EVA glove. The Space Suit RoboGlove (SSRG) uses a system of three linear actuators to pull synthetic tendons attached to the glove's fingers to augment flexion of the user's fingers. To detect the user's inputs, the system utilizes a combination of string potentiometers along the back of the fingers and force sensitive resistors integrated into the fingertips of the glove cover layer. This paper discusses the development process from initial concepts through two major phases of prototypes, and the results of initial human testing. Initial work on the project focused on creating a functioning proof of concept, designing the softgoods integration, and demonstrating augmented grip strength with the actuators. The second year of the project focused on upgrading the actuators, sensors, and software with the overall goal of creating a system that moves with the user's fingers in order to reduce fatigue associated with the operation of a pressurized glove system. This paper also discusses considerations for a flight system based on this prototype development and address where further work is required to mature the technology.

Rogers, Jonathan M.↗