Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FILM BOILING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Phase change in liquid face seals

A study is made of boiling (or phase change) in liquid face seals. An appropriate model is set up and approximate solutions obtained. Some practical illustrative examples are given. Major conclusions are that (1) boiling may occur more often than has been suspected particularly when the sealed liquid is near saturation conditions, (2) the temperature variation in a seal clearance region may not be very great and the main reason for boiling is the flashing which occurs as the pressure decreases through the seal clearance, and (3) there are two separate values of the parameter film-thickness/angular-velocity-squared (and associated radii where phase change takes place) which provide the same separating force under a given set of operating conditions. For a given speed seal face excursions about the larger spacing are stable, but excursions about the smaller spacing are unstable, leading to a growth to the larger spacing or a catastrophic collapse.

Hughes, W. F.↗

CTF Validation and Verification: Version 4.3

Coolant-Boiling in Rod Arrays- Two Fluids (COBRA-TF) is a thermal/hydraulic (T/H) simulation code designed for light water reactor (LWR) analysis. It uses a two-fluid, three-field (i.e., fluid film, fluid drops, and vapor) modeling approach. Both subchannel and 3D Cartesian forms of nine conservation equations are available for LWR modeling. The code was originally developed by Pacific Northwest Laboratory in 1980 and has been used and modified by several institutions over the last several decades. COBRA-TF is also used at the Pennsylvania State University (PSU) by the Reactor Dynamics and Fuel Modeling Group (RDFMG) and has been improved, updated, and subsequently became the CTF. One part of the improvement process includes validating the methods in CTF. This document seeks to provide a certain level of certainty and confidence in the predictive capabilities of the code for the scenarios it was designed to model—rod bundle geometries with operating conditions that are representative of prototypical pressurized water reactor (PWR)s and boiling water reactor (BWR)s in both normal and accident conditions. This is done by modeling a variety of experiments that simulate these scenarios and then presenting a qualitative and quantitative analysis of the results that demonstrates the accuracy to which CTF is capable of capturing specific quantities of interest.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

CTF Validation and Verification: Version 4.4

Coolant-Boiling in Rod Arrays- Two Fluids (COBRA-TF) is a thermal/hydraulic (T/H) simulation code designed for light water reactor (LWR) analysis. It uses a two-fluid, three-field (i.e., fluid film, fluid drops, and vapor) modeling approach. Both subchannel and 3D Cartesian forms of nine conservation equations are available for LWR modeling. The code was originally developed by Pacific Northwest Laboratory in 1980 and has been used and modified by several institutions over the last several decades. COBRA-TF is also used at the Pennsylvania State University (PSU) by the Reactor Dynamics and Fuel Modeling Group (RDFMG) and has been improved, updated, and subsequently became the CTF. One part of the improvement process includes validating the methods in CTF. This document seeks to provide a certain level of certainty and confidence in the predictive capabilities of the code for the scenarios it was designed to model—rod bundle geometries with operating conditions that are representative of prototypical pressurized water reactor (PWR)s and boiling water reactor (BWR)s in both normal and accident conditions. This is done by modeling a variety of experiments that simulate these scenarios and then presenting a qualitative and quantitative analysis of the results that demonstrates the accuracy to which CTF is capable of capturing specific quantities of interest.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fast photo-switchable surfaces for boiling heat transfer applications

Several milligrams of the ruthenium-centered organometallic complex, ruthenium bis-4,4 Prime -di(thiomethyl)-2,2 Prime -bipyridine, mono-2 -(2-pyridyl)-1,3-oxathiane ([Ru{l_brace}(HS-CH{sub 2}){sub 2}-bpy{r_brace}{sub 2}{l_brace}pox{r_brace}](PF{sub 6}){sub 2}) were synthesized and used to produce a self assembled monolayer film on a gold substrate. X-ray photoelectron spectroscopy analysis of the film detected the presence of bound thiolate, which is an indication of a chemisorbed film. Water contact angle measurements were performed before and after 5 min of visible light irradiation using an ozone-free 1000 W Xe(Hg) arc source with a 425-680 nm long pass mirror. The contact angle changed from 52 Degree-Sign pre-irradiation (hydrophilic state) to 95 Degree-Sign post-irradiation (hydrophobic state).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

CTF Validation and Verification Manual

Coolant-Boiling in Rod Arrays- Two Fluids (COBRA-TF) is a Thermal/Hydraulic (T/H) simulation code designed for Light Water Reactor (LWR) analysis. It uses a two-fluid, three-field (i.e. fluid film, fluid drops, and vapor) modeling approach. Both sub-channel and 3D Cartesian forms of nine conservation equations are available for LWR modeling. The code was originally developed by Pacific Northwest Laboratory in 1980 and has been used and modified by several institutions over the last several decades. COBRA-TF is also used at the Pennsylvania State University (PSU) by the Reactor Dynamics and Fuel Management Group (RDFMG), and has been improved, updated, and subsequently became the PSU RDFMG version of COBRA-TF (CTF). One part of the improvement process includes validating the methods in CTF. This document seeks to provide a certain level of certainty and confidence in the predictive capabilities of the code for the scenarios it was designed to model--rod bundle geometries with operating conditions that are representative of prototypical Pressurized Water Reactor (PWR)s and Boiling Water Reactor (BWR)s in both normal and accident conditions. This is done by modeling a variety of experiments that simulate these scenarios and then presenting a qualitative and quantitative analysis of the results that demonstrates the accuracy to which CTF is capable of capturing specific quantities of interest.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

CTF 4.0 Validation and Verification

Coolant-Boiling in Rod Arrays- Two Fluids (COBRA-TF) is a Thermal/Hydraulic (T/H) simulation code designed for Light Water Reactor (LWR) analysis. It uses a two-fluid, three-field (i.e. fluid film, fluid drops, and vapor) modeling approach. Both sub-channel and 3D Cartesian forms of nine conservation equations are available for LWR modeling. The code was originally developed by Pacific Northwest Laboratory in 1980 and has been used and modified by several institutions over the last several decades. COBRA-TF is also used at the Pennsylvania State University (PSU) by the Reactor Dynamics and Fuel Modeling Group (RDFMG) and has been improved, updated, and subsequently became the PSU RDFMG version of COBRA-TF (CTF). One part of the improvement process includes validating the methods in CTF. This document seeks to provide a certain level of certainty and confidence in the predictive capabilities of the code for the scenarios it was designed to model—rod bundle geometries with operating conditions that are representative of prototypical Pressurized Water Reactor (PWR)s and Boiling Water Reactor (BWR)s in both normal and accident conditions. This is done by modeling a variety of experiments that simulate these scenarios and then presenting a qualitative and quantitative analysis of the results that demonstrates the accuracy to which CTF is capable of capturing specific quantities of interest.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

CTF Validation and Verification (V.4.2)

Coolant-Boiling in Rod Arrays- Two Fluids (COBRA-TF) is a thermal/hydraulic (T/H) simulation code designed for Light Water Reactor (LWR) analysis. It uses a two-fluid, three-field (i.e. fluid film, fluid drops, and vapor) modeling approach. Both sub-channel and 3D Cartesian forms of nine conservation equations are available for LWR modeling. The code was originally developed by Pacific Northwest Laboratory in 1980 and has been used and modified by several institutions over the last several decades. COBRA-TF is also used at the Pennsylvania State University (PSU) by the Reactor Dynamics and Fuel Modeling Group (RDFMG) and has been improved, updated, and subsequently became the PSU RDFMG version of COBRA-TF (CTF). One part of the improvement process includes validating the methods in CTF. This document seeks to provide a certain level of certainty and confidence in the predictive capabilities of the code for the scenarios it was designed to model-rod bundle geometries with operating conditions that are representative of prototypical Pressurized Water Reactor (PWR)s and Boiling Water Reactor (BWR)s in both normal and accident conditions. This is done by modeling a variety of experiments that simulate these scenarios and then presenting a qualitative and quantitative analysis of the results that demonstrates the accuracy to which CTF is capable of capturing specific quantities of interest.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Phase change in liquid face seals. II - Isothermal and adiabatic bounds with real fluids

Analytical studies of phase change effects in parallel and tapered liquid face seals are presented. An isothermal and adiabatic model of low Reynolds number flow are considered by numerical integration of the descriptive equations for a real fluid, and its thermodynamic properties are calculated for each step, using a computer program for the steam tables or fluid thermodynamic properties. It was shown that for low leakage rate the isothermal model is more accurate and for high leakage rates the adiabatic model is more accurate; that both models yield the same conclusions regarding stability; and that the transient of collapse is described by the adiabatic model which predicts a catastrophic collapse and then either failure or explosive return to a larger film thickness value. Finally, it is shown that converging seals may become unstable and the mass leakage rate is reduced significantly below the all liquid value when boiling occurs.

Hughes, W. F.↗

Initiation of Flash Boiling of Multicomponent Miscible Mixtures with Application to Transportation Fuels and Their Surrogates

This paper presents methodologies to predict thermodynamic conditions that initiate flash boiling by spontaneous nucleation of liquids consisting of hundreds of miscible liquids and their lower order surrogate mixtures. The methods are illustrated with a kerosene-based fuel and a seven-component surrogate for it. The predictions are compared to measurements of nucleation temperatures obtained from a pulse-heating technique that rapidly heats a microscale platinum film immersed in a pool of the test fluid. Nucleation temperatures are predicted using a generalized corresponding states principle (GCSP), and a modification of classical nucleation theory that considers the mixture as a pseudo single component fluid (PSCF). The intent is to offer a simple means to predict the initiation of flash boiling that can have important consequences for fuel efficiency in combustion engines. We show that contact angle has a strong effect such that predicted and measured spontaneous nucleation temperatures agree for a given heating rate only if contact angle is accounted for in the theory. For low heating rates (less than 2 × 10 7 K/s), predicted nucleation temperatures, assuming a spherical bubble, are 13% higher than measurements. The gap is closed to about 6% as the heating rate reaches 3 × 10 8 K/s (the highest that could be reached in the experiments) and to less than 1% when the measured nucleation temperature is extrapolated to an asymptotic (zero contact angle) limit. Here, the PSCF method (using mixture properties as mole fraction averages of mixture component properties evaluated at the same reduced temperatures as the mixtures) and the GSCP predict virtually identical nucleation temperatures, while the GCSP method does not require any mixture property values.

42 ENGINEERING↗

Interfacial mode coupling as the origin of the enhancement of T c in FeSe films on SrTiO 3

Films of iron selenide (FeSe) one unit cell thick grown on strontium titanate (SrTiO 3 or STO) substrates have recently shown superconducting energy gaps opening at temperatures close to the boiling point of liquid nitrogen (77 K), which is a record for the iron-based superconductors. The gap opening temperature usually sets the superconducting transition temperature T c , as the gap signals the formation of Cooper pairs, the bound electron states responsible for superconductivity. To understand why Cooper pairs form at such high temperatures, we examine the role of the SrTiO 3 substrate. Here we report high-resolution angle-resolved photoemission spectroscopy results that reveal an unexpected characteristic of the single-unit-cell FeSe/SrTiO 3 system: shake-off bands suggesting the presence of bosonic modes, most probably oxygen optical phonons in SrTiO 3 , which couple to the FeSe electrons with only a small momentum transfer. Such interfacial coupling assists superconductivity in most channels, including those mediated by spin fluctuations. Our calculations suggest that this coupling is responsible for raising the superconducting gap opening temperature in single-unit-cell FeSe/SrTiO 3 .

36 MATERIALS SCIENCE↗

Investigations of the small-scale thermal behavior of sol-gel thermites.

Sol-gel thermites, formulated from nanoporous oxides and dispersed fuel particles, may provide materials useful for small-scale, intense thermal sources, but understanding the factors affecting performance is critical prior to use. Work was conducted on understanding the synthesis conditions, thermal treatments, and additives that lead to different performance characteristics in iron oxide sol-gel thermites. Additionally, the safety properties of sol-gel thermites were investigated, especially those related to air sensitivity. Sol-gel thermites were synthesized using a variety of different techniques and there appear to be many viable routes to relatively equivalent thermites. These thermites were subjected to several different thermal treatments under argon in a differential scanning calorimeter, and it was shown that a 65 C hold for up to 200 minutes was effective for the removal of residual solvent, thus preventing boiling during the final thermal activation step. Vacuum-drying prior to this heating was shown to be even more effective at removing residual solvent. The addition of aluminum and molybdenum trioxide (MoO{sub 3}) reduced the total heat release per unit mass upon exposure to air, probably due to a decrease in the amount of reduced iron oxide species in the thermite. For the thermal activation step of heat treatment, three different temperatures were investigated. Thermal activation at 200 C resulted in increased ignition sensitivity over thermal activation at 232 C, and thermal activation at 300 C resulted in non-ignitable material. Non-sol-gel iron oxide did not exhibit any of the air-sensitivity observed in sol-gel iron oxide. In the DSC experiments, no bulk ignition of sol-gel thermites was observed upon exposure to air after thermal activation in argon; however ignition did occur when the material was heated in air after thermal treatment. In larger-scale experiments, up to a few hundred milligrams, no ignition was observed upon exposure to air after thermal activation in vacuum; however ignition by resistively-heated tungsten wire was possible. Thin films of thermite were fabricated using a dispersed mixture of aluminum and iron oxide particles, but ignition and propagation of these films was difficult. The only ignition and propagation observed was in a preheated sample.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Percolation effect in thick film superconductors: Using a Bi(Pb)SrCaCuO based paste to prepare a superconducting planar transformer

A thick film superconductor paste has been developed to study the properties of granulated superconductor materials, to observe the percolation effect and to confirm the theory of the conducting mechanism in the superconducting thick films. This paste was also applied to make a superconducting planar transformer. Due to the T(sub c) and advantageous current density properties the base of the past was chosen to be of Bi(Pb)SrCaCu) system. For contacts a conventional Ag/Pt paste was used. The critical temperature of the samples were between 110 K and 115 K depending on the printed layer thickness. The critical current density -at the boiling temperature of the liquid He- was between 200 - 300 A/sq cm. The R(T) and V(I) functions were measured with different parameters. The results of the measurements have confirmed the theory of conducting mechanism in the material. The percolation structure model has been built and described. As an application, a superconducting planar thick film transformer was planned and produced. Ten windings of the transformer were printed on one side of the alumina substrate and one winding was printed on the other side. The coupling between the two sides was possible through the substrate. The samples did not need special drying and firing parameters. After the preparation, the properties of the transformer were measured. The efficiency ans the losses were determined. Finally, some fundamental advantages and problems of the process were discussed.

Sali, Robert↗

CTF Theory Manual (V.4.2)

Coolant-Boiling in Rod Arrays—Two Fluids (COBRA-TF) is a thermal/hydraulic (T/H) simulation code designed for light water reactor (LWR) vessel analysis. It uses a two-fluid, three-field (i.e. fluid film, fluid drops, and vapor) modeling approach. Both sub-channel and 3D Cartesian forms of 9 conservation equations are available for LWR modeling. The code was originally developed by Pacific Northwest Laboratory in 1980 and had been used and modified by several institutions over the last few decades. COBRA-TF also found use at the Pennsylvania State University (PSU) by the Reactor Dynamics and Fuel Modeling Group (RDFMG) and has been improved, updated, and subsequently re-branded as CTF. As part of the improvement process, it was necessary to generate sufficient documentation for the open-source code which had lacked such material upon being adopted by RDFMG. This document serves mainly as a theory manual for CTF, detailing the many two-phase heat transfer, drag, and important accident scenario models contained in the code as well as the numerical solution process utilized. Coding of the models is also discussed, all with consideration for updates that have been made when transitioning from COBRA-TF to CTF. Further documentation outside of this manual is also available at RDFMG which focus on code input deck generation and source code global variable and module listings

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Acoustic Insights into Flow Condensation Mechanisms

Two-phase thermal management systems, with both boiling and condensation processes, offer great potential and heat transfer coefficients that are orders of magnitude higher than traditional single-phase systems. However, two-phase flows can suffer from a wide range of interfacial instabilities leading to significant thermal performance degradation. In this study, we aim to detect regime transitions and characterize dominating physical mechanisms of flow condensation, such as turbulent diffusion in annular liquid film and interfacial waves, using an integrated system of acoustic, modal, and optical sensing techniques and thermofluidic characterizations. A wideband acoustic emissions sensor and high-sensitivity accelerometer are utilized to capture acoustic and vibrational signatures that signal the onset of liquid film formation and interfacial waves during flow pattern transitions. Compared to optical imaging, wideband acoustic emission sensing allows for higher sampling rates to capture high-frequency interface oscillations critical to the flow regime transitions and works well even for condensation in opaque tubes. Acoustic features (e.g., amplitude, frequency, energy, duration) are correlated with thermofluidic processes (e.g., capillary flows, turbulent flows, boiling, condensation). By relating thermal performance metrics with these dynamic signatures in acoustic and modal regimes, we explore the ability to probe and monitor critical flow regime transitions and transport efficiency in flow condensation.

Acoustic Modal Regimes↗

Centrifugal inertia effects in two-phase face seal films

A simplified, semianalytical model has been developed to analyze the effect of centrifugal inertia in two-phase face seals. The model is based on the assumption of isothermal flow through the seal, but at an elevated temperature, and takes into account heat transfer and boiling. Using this model, seal performance curves are obtained with water as the working fluid. It is shown that the centrifugal inertia of the fluid reduces the load-carrying capacity dramatically at high speeds and that operational instability exists under certain conditions. While an all-liquid seal may be starved at speeds higher than a 'critical' value, leakage always occurs under boiling conditions.

Basu, P.↗

Unified descriptor for enhanced critical heat flux during pool boiling of hemi-wicking surfaces

Boiling heat transfer is dictated by interfacial phenomena at the three-phase contact line where vapor bubbles form on the surface. Structured surfaces have shown significant enhancement in critical heat flux (CHF) during pool boiling by tailoring interfacial phenomena. This CHF enhancement has been primarily explained by two structural effects: roughness, which extends the contact line length at the bubble base, and wickability, the ability to imbibe liquid through surface structures by capillary pumping. Here, in this work, we show that CHF enhancement on structured surfaces cannot be described by roughness or wickability alone. This result was confirmed using systematically designed micropillar surfaces with controlled roughness and wickability. Further, we performed a scaling analysis and derived a unified descriptor, which represents the combined effects of thin film density and volumetric wicking rate. This unified descriptor shows a reasonable correlation with CHF values with our experiments and literature data. This work provides important insights in understanding the role of surface structures on CHF enhancement, thereby providing guidelines for the systematic design of surface structures for enhanced pool boiling heat transfer.

42 ENGINEERING↗

Transmittance jump in a thin aluminium layer during laser ablation

A jump in the transmittance (from ∼0.1% to ∼50% for ∼1 ns) of an optical gate on a Mylar film (a thin aluminium layer on a Lavsan substrate) irradiated by nanosecond (10{sup -7} – 10{sup -8} s) pulses of a neodymium laser with an intensity up to 0.1 GW cm{sup -2} has been recorded. The mechanism of a fast (10{sup -10} – 10{sup -11} s) increase in the transmittance of the aluminium layer upon its overheating (without boiling) to the metal – insulator phase-transition temperature is discussed. (interaction of laser radiation with matter. laser plasma)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Superconductivity in Oxides Generated by Percolating Electron or Hole Bipolarons

It is remarkable that in over three decades since the discovery of high-temperature superconductivity (HTS) in cuprates, no other class of materials has been found to exhibit this property above the liquid nitrogen boiling point at ambient pressure. Here, we describe the conformation of hole and electron bipolarons in doped cuprates and tungstates. Important similarities and differences between them are discussed. Both hole and electron bipolarons can percolate forming filaments or clusters in the bulk or on the surfaces as well. Upon cooling, these electronic objects can show superconducting properties. It is proposed that oxygen-reduced tungsten oxide WO{sub 3−x} in bulk or thin film form is a promising material to explore the HTS. Such material would be another example of bipolaronic superconductivity similar to cuprates. However, there is also an important difference: in the cuprates, holes predominantly enter the oxygen orbitals and hole bipolarons are composed of three-spin polarons, whereas in the tungstates, doped electrons are located on tungsten ions and W{sup 5+}–O{sup 2−}–W{sup 5+}electron bipolarons form from 5d{sup 1} W{sup 5+} polarons.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗