Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy use”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Understanding Multifamily Energy Use in Brownsville-Corpus Christi-McAllen-Victoria Areas: Building Stock Segmentation for Retrofit Planning

This report is an addendum to a publication series that focuses on approximately 100 different local geographies, or "clusters". This addendum expands the report series to include large multifamily building characteristics as well as energy and emission data for each local geography. The intention of this addendum is to help policymakers at the city, county, and state levels better understand building energy use and emissions in large multifamily buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Understanding Multifamily Energy Use in the Greater Central Virginia and Eastern Shore Area: Building Stock Segmentation for Retrofit Planning

This report is an addendum to a publication series that focuses on approximately 100 different local geographies, or "clusters". This addendum expands the report series to include large multifamily building characteristics as well as energy and emission data for each local geography. The intention of this addendum is to help policymakers at the city, county, and state levels better understand building energy use and emissions in large multifamily buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Understanding Multifamily Energy Use in the Knoxville-Chattanooga-Asheville and Greenville, SC Area: Building Stock Segmentation for Retrofit Planning

This report is an addendum to a publication series that focuses on approximately 100 different local geographies, or "clusters". This addendum expands the report series to include large multifamily building characteristics as well as energy and emission data for each local geography. The intention of this addendum is to help policymakers at the city, county, and state levels better understand building energy use and emissions in large multifamily buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Understanding Multifamily Energy Use in Rural West Texas and Oklahoma and Southern New Mexico: Building Stock Segmentation for Retrofit Planning

This report is an addendum to a publication series that focuses on approximately 100 different local geographies, or "clusters". This addendum expands the report series to include large multifamily building characteristics as well as energy and emission data for each local geography. The intention of this addendum is to help policymakers at the city, county, and state levels better understand building energy use and emissions in large multifamily buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Understanding Multifamily Energy Use in the Greater Nashville and Hopkinsville-Bowling Green Area: Building Stock Segmentation for Retrofit Planning

This report is an addendum to a publication series that focuses on approximately 100 different local geographies, or "clusters". This addendum expands the report series to include large multifamily building characteristics as well as energy and emission data for each local geography. The intention of this addendum is to help policymakers at the city, county, and state levels better understand building energy use and emissions in large multifamily buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Understanding Multifamily Energy Use in Small Urban Areas in the Dakotas, Idaho, Montana, and Wyoming: Building Stock Segmentation for Retrofit Planning

This report is an addendum to a publication series that focuses on approximately 100 different local geographies, or "clusters". This addendum expands the report series to include large multifamily building characteristics as well as energy and emission data for each local geography. The intention of this addendum is to help policymakers at the city, county, and state levels better understand building energy use and emissions in large multifamily buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Understanding Multifamily Energy Use in the Spokane-Coeur d'Alene-Lewiston-Yakima-Wenatchee Area: Building Stock Segmentation for Retrofit Planning

This report is an addendum to a publication series that focuses on approximately 100 different local geographies, or "clusters". This addendum expands the report series to include large multifamily building characteristics as well as energy and emission data for each local geography. The intention of this addendum is to help policymakers at the city, county, and state levels better understand building energy use and emissions in large multifamily buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Life Cycle Assessment of Pasture-based Agrivoltaic Systems: Emissions and Energy Use of Integrated Rabbit Production

Agrivoltaic systems, which deliberately maximize the utility of a single parcel of land for both solar photovoltaic (PV) electricity production and agriculture, have been demonstrated as a viable technology that can ameliorate competing land uses and meet growing energy and food demands efficiently. The goal of this study is to assess the environmental impacts of a novel pasture-based agrivoltaic concept: co-farming rabbits and solar PV. A life cycle assessment (LCA) quantified the impacts of 1) the integrated agrivoltaic concept in comparison to conventional practices including 2) separate rabbit farming and PV production and 3) separate rabbit farming and conventional electricity production. The impact assessment methods employed to determine the environmental impacts were IPCC 2013 global warming potential 100a V1.03 and fossil energy demand V1.11. The results indicate that the pasture-based agrivoltaic system produces the least amount of greenhouse gas emissions (3.8 million kg CO₂ equivalent) and demands the least amount of fossil energy (46 million MJ) per functional unit of cumulative MWh output of electricity and cumulative kg of meat over 30 years in comparison to the two other scenarios under study. The pasture-based agrivoltaic system features a dual synergy that consequently produces 69.3% less emissions and demands 82.9% less fossil energy compared to non-integrated production. The potential for agrivoltaic systems to significantly reduce environmental impacts revealed by this LCA, which was limited to emissions and fossil energy demand, demonstrates that integrated solar and pasture-based agricultural systems are superior to conventional practices in terms of their comparatively lower emission and energy intensity. These findings provide empirical support for increased agrivoltaic system development more broadly.

14 SOLAR ENERGY↗

Understanding Multifamily Energy Use in the Greater Columbia-Fayetteville-Jefferson City-Joplin-Springfield-Wichita Areas: Building Stock Segmentation for Retrofit Planning

This report is an addendum to a publication series that focuses on approximately 100 different local geographies, or "clusters". This addendum expands the report series to include large multifamily building characteristics as well as energy and emission data for each local geography. The intention of this addendum is to help policymakers at the city, county, and state levels better understand building energy use and emissions in large multifamily buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effect of water velocity and temperature on energy use, behaviour and mortality of pallid sturgeon Scaphirhynchus albus larvae

Abstract Natural reproduction of pallid sturgeon Scaphirhynchus albus has been limited for decades and a recruitment bottleneck is hypothesized to occur during the larval stage of development. In this study, we evaluated the effects of water velocity and temperature on the swimming activity, energy use, settling behaviour and mortality of endogenously feeding larvae. The swimming activity of drifting sturgeon larvae ( i.e. , fish exhibiting negative rheotaxis) increased at low water velocity. In subsequent experiments, we observed greater energy depletion and resultant mortality of larvae in no‐flow environments (0 cm s −1 ) compared to tanks with water velocity ranging from 3.5 to 8.3 cm s −1 . The growth rate of drifting larvae was positively related to water temperature (18.7–23.3°C), but reduced growth rate at low water temperature (18.7°C) resulted in protracted development that extended average drift duration by ~4 days compared to larvae reared at 23.3°C. This study provides evidence that cooler summer water temperatures, characteristic of present‐day conditions in the upper Missouri River, can reduce larval development and extend both the drift duration and distance requirements of S. albus . Moreover, if dispersed into low velocity environments, such as in reservoir headwaters, larvae may experience increased mortality owing to a mismatch between early life stage drift requirements and habitat conditions in the river. Manipulation of water releases to increase seasonal water temperature below dams may aid survival of S. albus larvae by shortening the time and distance spent drifting.

Mrnak, Joseph T.↗

Small Hydropower Plant Response Improvement Using Energy Storage

Small hydropower plants contribute significantly to global power generation. However, due to limited storage, these can have low ramping capacity and poor load-frequency regulation. These can prevent small hydropower plants from being used in isolated grids as backup power to critical loads and rural areas. In this paper, a control architecture for frequency control is proposed that facilitates the use of energy storage to improve the response of standalone small hydropower plants. The frequency controller generates power commands using proportional control on frequency deviation and a user-defined power setpoint, and this incorporates with a current controller that facilitates power injection. The distinctive feature of the controller design is that it takes into account frequency thresholds and storage constraints to enable power injections, and it provides the capability to perform automated and manual recharge of the energy storage. Simulations using detailed nonlinear models demonstrate the improved performance of the hydropower with energy storage using the proposed controller. Automated and manual recharge and the impact of the energy storage constraints on the performance of the hydropower plant are demonstrated.

13 HYDRO ENERGY↗

Convergent Protocols for Computing Protein–Ligand Interaction Energies Using Fragment-Based Quantum Chemistry

Fragment-based quantum chemistry methods offer a way to sidestep the steep nonlinear scaling of electronic structure calculations so that large molecular systems can be investigated using high-level methods. Here, we use fragmentation to compute protein–ligand interaction energies in systems with several thousand atoms, using a new software platform for managing fragment-based calculations that implements a screened many-body expansion. Convergence tests using a minimal-basis semiempirical method (HF-3c) indicate that two-body calculations, with single-residue fragments and simple hydrogen caps, are sufficient to reproduce interaction energies obtained using conventional supramolecular electronic structure calculations, to within 1 kcal/mol at about 1% of the computational cost. We also demonstrate that the HF-3c results are illustrative of trends obtained with density functional theory in basis sets up to augmented quadruple-ζ quality. Strategic deployment of fragmentation facilitates the use of converged biomolecular model systems alongside high-quality electronic structure methods and basis sets, bringing ab initio quantum chemistry to systems of hitherto unimaginable size. This will be useful for generation of high-quality training data for machine learning applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Magnetized ICF implosions: Ignition at low laser energy using designs with more ablator mass remaining

This paper is the first work to redesign a spherical ICF implosion to best utilize the benefits of applying an external magnetic field. The sub-ignition experiment N170601 is taken as the baseline design, which used 1.57 MJ of laser energy. The optimum magnetized design benefits from increasing the shell thickness by 14 μ m and decreasing the ice thickness by 18 μ m, resulting in a neutron yield of 8.9 × 10 17 . This is 34 × greater than the unmagnetized simulation of the same design, and 18.5 × the greatest unmagnetized simulation across all designs simulated. The resultant implosion velocity for the magnetized design is lower, which would also reduce ablation front instability growth. This design was found by using a simplified 1D magnetization model and then validated against full 2D extended-MHD capsule simulations with radiation asymmetries applied to correct the shape.

Walsh, Christopher A. [Lawrence Livermore National↗

Modeling and analysis of synthetic liquid fuel production from CO 2 and nuclear energy using methanol-to-diesel process

Electrofuels (e-fuels) are synthetic fuels produced from carbon dioxide (CO 2 ) and electricity for blending with or replacing petroleum fuels. Nuclear energy is an attractive energy feedstock for e-fuel production because of its low environmental footprint and its ability to provide steady heat and power essential for e-fuels production. We modeled and evaluated the cost and environmental footprint of e-fuels production in the distillate range for three nuclear power scales, 100, 500, and 1000 MWe, through methanol and olefins intermediates leveraging commercial or high technology readiness level (TRL) processes. Compared to the commonly studied e-fuels from Fischer Tropsch process that has a distillate yield of <70% with the rest being low value naphtha, the proposed process via methanol intermediate increases the product selectivity with distillate yield of 96% and only 4% naphtha. The modeled process has a carbon conversion ratio of 98%, and a process energy efficiency of 56% relative to the total equivalent nuclear electricity input. The e-fuel plant economics and GHG emissions were estimated by considering CO 2 collected from ethanol plants adjacent to nuclear power plants. The estimated minimum fuel selling prices (MFSP) of e-fuel is in the range of $5.7-$9.1/gal depending on e-fuel plant scale, electricity cost, and CO 2 transportation distance. The corresponding e-fuels life cycle GHG emissions is estimated in the range of 5-6 gCO 2 e/MJ of liquid fuel using the R&D Greenhouse gases, Regulated Emissions, and Energy use in Technologies (R&D GREET) model.

10 SYNTHETIC FUELS↗

Inequalities in global residential cooling energy use to 2050

Intersecting socio-demographic transformations and warming climates portend increasing worldwide heat exposures and health sequelae. Cooling adaptation via air conditioning (AC) is effective, but energy-intensive and constrained by household-level differences in income and adaptive capacity. Using statistical models trained on a large multi-country household survey dataset (n = 673,215), we project AC adoption and energy use to mid-century at fine spatial resolution worldwide. Globally, the share of households with residential AC could grow from 27% to 41% (range of scenarios assessed: 33-48%), implying up to a doubling of residential cooling electricity consumption, from 1220 to 1940 (scenarios range: 1590-2377) terawatt-hours yr. –1 , emitting between 590 and 1,365 million tons of carbon dioxide equivalent (MtCO 2 e). AC access and utilization will remain highly unequal within and across countries and income groups, with significant regressive impacts. Up to 4 billion people may lack air-conditioning in 2050. Our global gridded projections facilitate incorporation of AC’s vulnerability, health, and decarbonization effects into integrated assessments of climate change.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Managing Army Plug Load Equipment Energy Use: Vending Machines

Vending machines consume the most energy of individual plug load devices common to Army buildings. As a group, they rank fourth in total electricity consumption, behind only clothes dryers, laptop computers, and telecom loads. Upgrading 80% of the estimated 22,000 refrigerated vending machines on Army installations to the latest ENERGY STAR ® performance and optimizing their efficiency settings could save 31 million kWh and $2 million per year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantifying Airport Employee Commuting and Related Energy Use: A Comparison of Six US Airports

There has been growing research interest in understanding the energy signatures of airport access and egress as air travel continues to grow. However, these findings generally focus on airport access from the perspective of air travelers rather than ground access modes by airport employees. Using a data set of employment records, this paper uses residential location data of airport employees to estimate the energy implications of employee commuting at six major US airports based on commuting mode choice information from the US Census. This analysis reveals a high degree of variance in commuting energy usage by employees between different airports.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heat Loss Characteristics and Energy Use of Piperazine with the Advanced Stripper (PZAS) at the UT-SRP Pilot Plant

Heat duty and heat loss were measured at the pilot plant at UT Austin. Heat loss was measured with energy balances using water. Heat loss was studied using surface temperature measurements over 68 different locations at the pilot plant. Surface temperature measurements indicated that bare metal surfaces were the primary source of heat loss from the pilot plant. Heat loss from bare metal surfaces was at least 50% controlled by natural convection and in many cases was as high as 75% natural convection controlled. Measured heat loss at the pilot plant was 20100 BTU/hr and overall heat loss did not show any dependence on the heat rate of the plant. Compared to PZAS™ at the National Carbon Capture Center, heat loss relative to heat rate was higher at 38%. The relative heat loss at the pilot plants was found to decrease by 20% per MW of added capacity. Measured net heat duty was found to be dependent on measured lean loading and cold rich bypass flow rate. Measured net heat duty was between 2.2 and 2.4 GJ/tonne at an optimum lean loading of 0.2–0.21 mol/mol. Data reconciliation by Aspen Plus® Data Fit™ underpredicted CO2 flow rate by 20% due to an overprediction of lean loading by 19%, indicating a necessary change in thermodynamic parameters in the model. This resulted in an over prediction of heat duty by 33% on average.

Amine scrubbing, stripper, energy requirement, hea↗