Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy usage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Combining Reclaimed PET with Bio-Based Monomers Enables Plastics Upcycling

Less than 30% of PET plastic is recycled in the United States. The low reclamation rate may be due to mechanical recycling accounting for the majority of commercial PET recycling. Mechanical recycling yields a lower-quality recycled plastic than the process of chemically recycling back to the monomer phase, which can be energetically and economically expensive. In this work, recently published in Joule, reclaimed PET bottles are chemically recycled and converted into higher-value fiberglass-reinforced plastics (FRPs).This presentation will focus on the supply-chain level energy and greenhouse gas emissions intensities associated with this novel upcycling route. The Materials Flows through Industry supply chain analysis tool, developed at NREL, is used to estimate these impacts. Depending on the extent and speed of adoption, this strategy for plastic upcycling could lead to significant energy usage and emissions reductions over the traditional FRP supply chain. Overall, this approach may provide an economic incentive for plastics recycling and renewable feedstock use through the creation of higher-value FRPs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Crowder College MARET Center (Final Scientific Technical Report)

Following decades of success in solar energy projects, the Missouri Legislature designated Crowder College in 1992 as the State's renewable energy education center. The resulting Missouri Alternative and Renewable Energy Technology (MARET) Center is recognized internationally for its contributions to the energy field. The mission of the MARET Center is to expand renewable energy throughout the region with education, applied research, and economic development. Educational programs include certification and transfer degrees encompassing green construction, solar thermal energy, solar electricity, and wind. The MARET Center also assists in new product development and other business support services in renewable energy. The Missouri Alternative and Renewable Energy Technology (MARET) Center at Crowder College hopes to eventually develop a 27,500 ft 2 facility as a living laboratory to support solar and other renewable and sustainable energy development through professional degrees, new product development and commercialization, renewable energy business incubation, and consumer education. The primary objective of the current project was to complete Stage One of this building, with solar, wind, and geothermal technologies installed to power its 9,216 ft 2 office, classroom, and research spaces. This MARET Center includes a modular roof structure that permits both solar module mounting and daylighting, PV/thermal hybrid modules pioneered in Crowder Solar Decathlon homes, modular electrical management subsystems; and modular delivery systems for heating and cooling the structure. The MARET Facility will operate as a Net Positive energy building, consistently producing surplus energy for distributed generation on the utility grid. The modular design of the energy systems within the building is to serve as a scalable and repeatable model for a wide variety of building applications and climate zones. As a living laboratory of renewable energy, exploring and validating new applications of solar and other renewable technologies, the MARET Facility will house a wide variety of programs which will advance implementation of renewable energy throughout the region. These program goals include; Curriculum in renewable energy for pre-engineering transfer programs; Certification and degree programs for technical degrees for Energy Efficiency, Wind, Photovoltaic and Solar Thermal professionals; Short courses and workshops for building management and design professionals; Public education and demonstration projects in renewable energy through conferences and K-12 educational outreach; Technical degree offering in building construction incorporating “best practices” for energy efficiency and renewables; and Business incubators for new renewable energy businesses and new product development. The new MARET facility will support the mission of the US Department of Energy (DOE) Solar Program, “to improve America’s security, environmental quality, and economic prosperity through public-private partnerships that bring reliable and affordable solar energy technologies to the marketplace,” through a variety of educational and business assistance programs. Further, technical innovations planned for the MARET facility and its applied research activities will advance the Solar Program strategic goals to “reduce the cost of solar energy to the point it becomes competitive in relevant energy markets (e.g., buildings, power plants) and for solar technology to enable a sustainable solar industry.” Overarching Goals relative to program needs, future expansion, flexibility, quality of materials, and construction and operational costs:; Experimental: The structure and systems of the building operate as an educational resource. The systems are meant to be a source for data collection and study for building users and instructors; Educational: Part of the evolution of this building and its ongoing goals is to use the building as an educational tool, one where new ideas developed in the world and especially at Crowder can be tested further as part of MARET's curriculum; LEED Platinum: achieve highest level of LEED certification; Net Zero: The building will utilize existing wind and alternate energy sources on campus and add solar PVT panels and achieve as close as possible to a net zero energy usage; and Phase II: The phase II portion of this project will expand the Internet student area, additional classrooms, and labs, as well as an auditorium and exhibit area.

14 SOLAR ENERGY↗

SCORE (Synthesis of COnsists as Rolling Energy microgrids) (Final Technical Report)

The SCORE toolset is an open source, web-based application to assess the impact of new powering technologies on railroad performance, specifically technologies capable of both putting power into the rail (motive force) and taking power from the rail (regeneration). SCORE’s primary goal is generate trade studies to analyze different powering and train make-up options to minimize energy usage and greenhouse gas generation. At the core of generating these trade spaces is calculating the optimal powering policy for the train given the makeup of the train, the route, and time constraints. This paper presents details on the algorithms used in SCORE to compute this powering policies that is fast and accurate, discusses its implementation in an Energy-Longitudinal Train Dynamics (E-LTD) model, compares it to naïve approaches, and demonstrates its use across a variety of train/route pairs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Short-Term Energy and Meteorological Impacts on Thanksgiving CO2 in Salt Lake City

Abstract Long-term, high-frequency atmospheric CO2 measurements at multiple sites in the Salt Lake City (SLC), Utah, reveal that annual and monthly CO2 variability aligns with a priori estimates of emissions from anthropogenic and biological sources. In this study, we investigate whether short-term fluctuations in anthropogenic emissions, as captured in the Vulcan3 dataset for the United States, can be detected in atmospheric CO2 observations. Specifically, we focus on Thanksgiving holidays, when traffic and energy usage patterns differ from the rest of November. Onroad CO2 emissions exhibit a double peak during weekday morning and evening rush hours but remain relatively low on weekends and Thanksgiving. Interestingly, CO2 mole fractions during Thanksgiving were higher than the rest of November at all SLC monitoring sites, particularly from 2008 to 2013. This increase is partially attributed to elevated energy-related emissions — especially residential sources — and meteorological factors such as weak wind speeds, cold temperature, and a low planetary boundary layer height (PBLH).

 While CO₂ emissions and mole fraction patterns align over time, notable spatial differences exist. For instance, the near-highway site in Murray shows the highest CO₂ mole fractions despite low local emissions, suggesting pollution transport via highways and wind advection. Random Forest model-based SHapley Additive exPlanations (SHAP) analysis reveals that onroad emissions dominate CO2 contributions on weekdays and weekends, while energy-related emissions play a larger role during Thanksgiving, alongside meteorological drivers such as wind speed and PBLH. Across six urban cities, CO2 emissions display a consistent pattern: residential and commercial (onroad) emissions peak during Thanksgiving (weekday) with substantial (minimal) year-to-year variability. These findings highlight that urban CO₂ variability is driven by the combined influence of emissions and meteorology, underscoring the need for integrated mitigation strategies. Additionally, multi-site measurements are essential for accurate source attribution and the development of effective policy interventions. 

Ryoo, Ju-Mee (ORCID:0000000234256296)↗

Smart photovoltaics based on dye-sensitized solar cells using photochromic spiropyran derivatives as photosensitizers

In this paper, smart photovoltaic (SPV) devices, integrating both functions of solar cells and smart windows, was fabricated based on dye-sensitized solar cells using photochromic spiropyran derivatives SIBT as photosensitizers. SPV devices have self-regulated power conversion efficiency (PCE) and light transmission responding to the incident spectra due to the photoisomerization of SIBT. SIBT isomerize from closed-ring form to open-ring form under UV illumination, accompanied with enhanced visible light absorption and electron delocalization. Therefore, increased PCE and absorption in SPV devices were observed under UV treatment and the devices can be restored gradually to the initial status when kept in dark. The SPV devices have self-regulation of PCE and sunlight transmission responding to the changing sun spectra in different times of a day, providing a proper energy usage and a better sun-shading.

36 MATERIALS SCIENCE↗

Holographic patterning of high-performance on-chip 3D lithium-ion microbatteries

Significance Microscale batteries can deliver energy at the actual point of energy usage, providing capabilities for miniaturizing electronic devices and enhancing their performance. Here, we demonstrate a high-performance microbattery suitable for large-scale on-chip integration with both microelectromechanical and complementary metal-oxide–semiconductor (CMOS) devices. Enabled by a 3D holographic patterning technique, the battery possesses well-defined, periodically mesostructured porous electrodes. Such battery architectures offer both high energy and high power, and the 3D holographic patterning technique offers exceptional control of the electrode’s structural parameters, enabling customized energy and power for specific applications.

25 ENERGY STORAGE↗

Energy-Optimal Vehicle Longitudinal Motion Control via Pontryagin’s Minimum Principle and Ultra-Local Model

Longitudinal vehicle motion control is essential for enhancing performance and optimizing a vehicle’s energy usage. However, it remains a challenging task due to the nonlinear and uncertain nature of vehicle dynamics, along with varying driving conditions. This paper presents a novel ultra-local optimal control approach based on Pontryagin’s Minimum Principle (PMP) that circumvents the need for detailed system identification by employing an ultra-local model. The control objective is to minimize the total energy consumption under boundary conditions while ensuring smooth traction force generation. The proposed approach is evaluated using a high-fidelity vehicle model in three representative scenarios: (i) nominal driving, (ii) a change in tire road friction coefficient (TRFC) from 0.5 to 0.65 and road slope from 0% to 5% during the maneuver, with target velocity unchanged, and (iii) a change in target velocity from 20 m/s to 0 m/s during the maneuver, while maintaining nominal TRFC and slope conditions. The simulation results demonstrate that the proposed method delivers robust performance, effectively balancing consumption and tracking accuracy in all tested scenarios.

Waleed khan, Muhammad [The University of Texas at ↗

Quantifying Energy Flows in PV Circularity Processes: Preprint

As sustainability and end-of-life management become a hot topic to timely address in the PV community, a proper evaluation of the benefits of circular pathways such as recycling, reuse, and remanufacturing has not been performed holistically beyond material flows or LCA analysis. Energy flows are critical for evaluating energy generation technologies. Previously they have been used to compare renewables to fossil generation and then between PV technologies. This paper brings energy flows to bear on reaching circular pathways for PV. The energy flows to track energy usage, generation, and losses complementary to the mass flows are presented for silicon through the leverage of the PV ICE framework.

circular economy↗

Improving Gas Furnace Performance: A Field and Laboratory Study at End of Life

In 2010, natural gas provided 54% of total residential space heating energy the U.S. on a source basis, or 3.5 Quadrillion Btu. Natural gas burned in furnaces accounted for 92% of that total, and boilers and other equipment made up the remainder. A better understanding of installed furnace performance is a key to energy savings for this significant energy usage. Natural gas furnace performance can be measured in many ways. The annual fuel utilization efficiency (AFUE) rating provides a fixed value under specified conditions, akin to the EPA miles per gallon rating for new vehicles. The AFUE rating is provided by the manufacturer to the consumer and is a way to choose between models tested on the same basis. This value is commonly used in energy modeling calculations. ASHRAE 103 is a consensus furnace testing standard developed by the engineering community. The procedure provided in the standard covers heat-up, cool down, condensate heat loss, and steady-state conditions and an imposed oversize factor. The procedure can be used to evaluate furnace performance with specified conditions or with some variation chosen by the tester. In this report the ASHRAE 103 test result will be referred to as Annualized Efficiency (AE) to avoid confusion, and any non-standard test conditions will be noted. Aside from these two laboratory tests, steady state or flue loss efficiency can be measured in the field under many conditions; typically as found or tuned to the manufacturers recommended settings. In this report, AE and steady-state efficiency will be used as measures of furnace performance.

03 NATURAL GAS↗

Model Quality and Measurement Density Impact on Volt/Volt Ampere Reactive Optimization Performance

The operation of the utility grid is being reshaped by the continuous addition of distributed energy resources and advanced metering infrastructure, which challenge existing grid control strategies. Some utilities deploy advanced distribution management systems (ADMS) to assist with the consolidation of various applications and to augment situational awareness in response to the new power delivery dynamics. An ADMS is an integrated software platform that provides utilities with a way to enhance their reliability, control, and optimization with advanced applications, such as volt/VAR optimization (VVO). A VVO application could serve as a vehicle to deliver cost savings by providing the utility with a method to reduce rates by controlling the voltage and decreasing the energy usage in their service territory. Some utilities are reluctant to integrate an ADMS, because it is a significant investment that requires approval from the public regulatory commission and/or their customers. This paper evaluates the impact on VVO performance when using a lower-quality network model supplemented with additional measurements, which could provide an implementation for cost savings. The results show that a better model quality would provide the highest energy savings; however, some level of telemetry is necessary in all scenarios to prevent voltage exceedances.

24 POWER TRANSMISSION AND DISTRIBUTION↗

NREL RSF Energy Model 2011

Modern buildings are complex energy systems that must be controlled for energy efficiency. The Research Support Facility (RSF) at the National Renewable Energy Laboratory (NREL) has hundreds of controllers -- computers that communicate with the building's various control systems -- to control the building based on tens of thousands of variables and sensor points. These control strategies were designed for the RSF's systems to efficiently support research activities. Many events that affect energy use cannot be reliably predicted, but certain decisions (such as control strategies) must be made ahead of time. NREL researchers modeled the RSF systems to predict how they might perform. They then monitor these systems to understand how they are actually performing and reacting to the dynamic conditions of weather, occupancy, and maintenance. This submission includes the Energy Model from the RSF Systems Model. Comparing actual performance (metered) with expected performance (modeled) is key to understand corrective actions to ensure performance as originally intended. The Energy Model in this submission was made to model energy usage in the RSF and was compared to actual metered data to verify the model. Measured data and Weather data related to the RSF Systems Model can be found in the "Related Datasets" section of this submission.

2011↗

Energy characteristics of multi-chiller load distribution algorithms in a large office building

Here, this study evaluates the energy efficiency of multi-chiller systems in large office buildings, focusing on their optimization across various climate zones as defined by ASHRAE. Using EnergyPlus for simulations, the research examines five different load distribution algorithms in multi-chiller systems that range from one to ten chillers, aiming to understand their effectiveness in 15 distinct climate zones. The primary objectives of the study include identifying the energy efficiency of multi-chiller systems in each climate zone, determining the appropriate number of chillers for each zone, and evaluating the performance of the load distribution algorithms. Based on the U.S. Department of Energy’s commercial building model, the results suggest that multi-chiller systems can significantly reduce cooling energy consumption in various climates. Among the algorithms evaluated, the Sequential Uniform Part Load Ratio (SUPLR) algorithm demonstrates notable efficiency, especially in the 4A climate zone (Baltimore), where it achieves substantial energy savings. Applying the SUPLR algorithm in a multi-chiller setup with four chillers in this zone leads to an estimated 24.5 % reduction in energy usage, equivalent to 183 MW annually. The research indicates that a range of 3 to 5 chillers is typically optimal for most climate zones. In-depth analysis in the 4A climate zone highlights the importance of minimizing operation hours at low Part Load Ratios (PLR) to ensure that chillers operate at a high Coefficient of Performance (COP). This strategy underscores the potential of well-designed multi-chiller systems to reduce cooling energy demand, particularly in climates with transitional seasons. This study provides an overview of the energy-saving potential of multi-chiller systems, applicable across a variety of climatic scenarios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimized Gear Selection to Maximize Energy Savings in Electric Traction Drives for Medium and Heavy Duty Vehicles

Multi‑gear transmission systems are commonly used in electric traction drives for medium and heavy‑duty vehicles, while most passenger‑vehicle electric drivetrains rely on a single fixed ratio to reduce cost, weight, and complexity. Using multiple gear ratios can enable downsizing of the motor and inverter while still meeting performance requirements. Additionally, appropriately chosen ratios allow the motor to operate more frequently in high‑efficiency regions, improving overall energy usage and reducing operating costs over the drive cycle. This paper presents a systematic approach for selecting optimal gear ratios for electric drive systems. A neural‑network model is first developed to represent motor losses across the full torque–speed range using data generated from finite element analysis. This model enables fast, accurate evaluation of motor efficiency under varying operating conditions. A genetic‑algorithm‑based optimization framework is then applied to identify gear ratios that maximize energy cost savings over the drive cycle, with the resulting optimal ratios stored for real‑time implementation.

Gadiyar, Nishanth [ORNL] (ORCID:0000000348267524)↗

Advanced co-simulation framework for assessing the interplay between occupant behaviors and demand flexibility in commercial buildings

With buildings contributing significantly to electricity usage, enabling demand flexibility becomes a challenge, especially when accounting for occupant comfort. This study introduces an innovative co-simulation framework integrating multiple models: heating, ventilation, and air conditioning (HVAC) system, building zone load, indoor airflow, supervisory control, and occupant comfort and behavior. Uniquely, this framework allows for a comprehensive and dynamic analysis of building systems and occupant interactions in demand response events. Using this framework, we conducted a case study using a typical small office building model. Specifically, we focused on three areas: (1) the impact of indoor airflow modeling on energy use, occupant comfort, and behaviors forecasting, (2) the impact of occupant behaviors on demand flexibility, and (3) occupant comfort and behaviors under demand response events. Key performance indicators such as energy use, flexibility factor, durations of occupant discomfort and occupant behaviors were analyzed. Our findings indicated variations in energy usage and occupant comfort within demand flexibility events, marked by uncertainty boundaries, with variability in demand shedding up to 57.9%. Here, we concluded that this framework is suitable for analyzing typical commercial buildings and their HVAC systems in terms of demand flexibility potential under the impact of occupant behaviors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrated and Advanced Lighting Controls: The Next Frontier in Energy Savings?

Lighting energy use has significantly declined as a portion of overall building energy usage due largely to the uptake of more efficient light-emitting diode technology. Although the per unit cost of lighting controls has declined, the installation and use of lighting controls are low and the installation and use of advanced controls are abysmally low. Increased use of advanced and connected lighting controls, and the ability to integrate lighting with other building systems (e.g., heat and air, plug loads, miscellaneous loads) that make the building “smarter,” offer the potential for additional energy savings. Studies into the performance of new, advanced lighting control technologies in commercial buildings have generated new findings. Although each field evaluation has interesting results individually, an analysis of their collective findings across a spectrum of commercial building types will help establish the current state of the technology and implications related to market readiness. This paper will analyze results from available field evaluation studies (recently completed as well as ongoing) of retrofit sites and share findings and insights including: • The amount of energy savings that may be expected from these systems. • Cost effectiveness, monetization, and cost points of these systems. • Ideal characteristics of these systems the most viable. • Lessons learned from the installation, commissioning, and occupant response of these systems. The results will support Department of Energy research investments and help inform efficiency programs of the potential of these emerging technologies and how they may fit within the clean energy future.

Myer, Michael↗

Next-generation building energy management systems and implications for electricity markets.

The U.S. national electric grid is facing significant changes due to aggressive federal and state targets to decrease emissions while improving grid efficiency and reliability. Additional challenges include supply/demand imbalances, transmission constraints, and aging infrastructure. A significant number of technologies are emerging under this environment including renewable generation, distributed storage, and energy management systems. In this paper, we claim that predictive energy management systems can play a significant role in achieving federal and state targets. These systems can merge sensor data and predictive statistical models, thereby allowing for a more proactive modulation of building energy usage as external weather and market signals change. A key observation is that these predictive capabilities, coupled with the fast responsiveness of air handling units and storage devices, can enable participation in several markets such as the day-ahead and real-time pricing markets, demand and reserves markets, and ancillary services markets. Participation in these markets has implications for both market prices and reliability and can help balance the integration of intermittent renewable resources. In addition, these emerging predictive energy management systems are inexpensive and easy to deploy, allowing for broad building participation in utility centric programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Model Predictive Control of the Exit Part Temperature for an Austenitization Furnace

Quench hardening is the process of strengthening and hardening ferrous metals and alloys by heating the material to a specific temperature to form austenite (austenitization), followed by rapid cooling (quenching) in water, brine or oil to introduce a hardened phase called martensite. The material is then often tempered to increase toughness, as it may decrease from the quench hardening process. The austenitization process is highly energy-intensive and many of the industrial austenitization furnaces were built and equipped prior to the advent of advanced control strategies and thus use large, sub-optimal amounts of energy. The model computes the energy usage of the furnace and the part temperature profile as a function of time and position within the furnace under temperature feedback control. In this paper, the aforementioned model is used to simulate the furnace for a batch of forty parts under heuristic temperature set points suggested by the operators of the plant. A model predictive control (MPC) system is then developed and deployed to control the the part temperature at the furnace exit thereby preventing the parts from overheating. An energy efficiency gain of 5.3% was obtained under model predictive control compared to operation under heuristic temperature set points tracked by a regulatory control layer.

36 MATERIALS SCIENCE↗

Electrical and Thermal Load Impacts of Three District Heating and Cooling Designs for an Existing Community in Washington, DC

District energy systems that provide building heating and cooling are a promising option to provide low-cost, energy efficient heating and cooling solutions for communities. As some buildings move to electrified heating designs, there may be significant increases in electric grid demand, particularly in the winter. District energy systems may be able to help reduce these high electrical demands on the electric grid, while also providing decreased overall energy consumption with an increased flexibility in electrical energy usage. To evaluate and compare district options for district-based heating and cooling, an existing neighborhood of Washington, DC consisting of 35 existing buildings was selected as a case study. This study models and compares a fourth generation (4G) district heating and cooling systems that provide hot and chilled water from a central plant directly to each prosumer and a fifth generation (5G) district heating and cooling systems that provide near-ambient water via geothermal boreholes to interface with an energy transfer station with a heat pump at each prosumer. These district systems are compared against a baseline of the non-connected buildings with their self-contained and current HVAC systems. The neighborhood was selected as a good candidate for a district system for its diversity of loads (mix of different commercial and property types) and the availability of building characteristics. URBANopt District Energy Systems (DES) was used to model the buildings and create initial Modelica models for the district systems. Finally, the DES models were tuned and simulated in Dymola, and the outputs were post-processed for verification and to calculate the electrical and thermal grid impact metrics. This is the first documentation of this workflow and its complete analysis. The three designed systems are compared via their grid metrics including: total energy consumption, electrical demand peak loads, daily peak-to-valley ratios, and system ramping. A detailed discussion is provided about how each system impacts and interacts with the electric grid.

15 GEOTHERMAL ENERGY↗