Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electromagnetic Simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Beam Measurements of the Tianlai Dish Radio Telescope using an Unmanned Aerial Vehicle

Precision measurement of the beam pattern of an antenna is very important for many applications. While traditionally such measurement is often made in a microwave anechoic chamber or at a test range, measurement using an unmanned aerial vehicle offers a number of advantages: the measurement can be made for the assembled antenna on site, thus reflecting the actual characteristics of the antenna of interest, and more importantly, it can be performed for larger antennas which cannot be steered or easily measured using the anechoic chamber and test range. Here we report our beam measurement experiment with UAV for a 6 meter dish used in the Tianlai array, which is a radio astronomy experiment. Due to the dish's small collecting area, calibration with an astronomical source only allows for determining the antenna beam pattern over a very limited angular range. We describe in detail the setup of the experiment, the components of the signal transmitting system, the design of the flight path and the procedure for data processing. We find the UAV measurement of the beam pattern agrees very well with the astronomical source measurement in the main lobe, but the UAV measurement can be extended to the fourth side lobe. The measured position and width of each lobe also shows good agreement with electromagnetic field simulation. This UAV-based approach of beam pattern measurement is flexible and inexpensive, and the technique may also be applied to other experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Grid Forming Control of PMSG-based Wind Turbines under Fault Conditions

Grid-forming control is widely envisioned as core technology ensuring stable operation of future power systems with increasing deployment of converter-interfaced renewable generation. However, research on grid forming control of wind turbines, especially under faults, is still in its early stages. In this context, this paper augments dual-port grid-forming control for type IV wind turbines with auxiliary controls to enable reliable fault ride through capabilities. In particular, the proposed control does not require a dc chopper or mode switching to grid-following control. Instead, energy-balancing dual-port GFM control is augmented with active rotor speed damping control and threshold virtual impedance for current limiting during faults. Different operating conditions of wind turbines are considered in a detailed electromagnetic transient simulation study to validate the effectiveness of the proposed control.

Lyu, Xue↗

FIDVR Capability of Hybrid Grid-Forming PV Power Plants During Feeder Restoration

Grid-forming inverters must optimally transfer power from dc-coupled photovoltaic arrays and batteries into an ac grid. Further, they must be able to restore single-phase induction motors (SPIMs) and withstand fault-induced delayed voltage-recovery (FIDVR) events. These resilience and reliability challenges are addressed here by: (i) engineering a controller to optimally operate dc-coupled hybrid resources; (ii) modeling residential air-conditioning compressors for restoration/FIDVR studies; and (iii) analyzing SPIM thermal-relay performance under limited inverter currents and designing an electronic protection for stalled SPIMs. Furthermore, these contributions are demonstrated via electromagnetic-transient simulations and can be helpful to understand recommendations by the North American Electric Reliability Corporation.

14 SOLAR ENERGY↗

Small-Signal Stability of Grid-Forming Converters Under Fault Conditions

Threshold virtual impedance (TVI)-based current limiting for grid-forming converters (GFMs) has gained great interest due to its ability to maintain voltage source behaviour during faults. However, sequence component extraction (SCE) and negative-sequence control (NSC) are often overlooked in small-signal stability assessments during faults. This paper develops small-signal sequence impedance models for GFMs under four well-known SCE methods based on TVI current limiting control during symmetrical fault conditions. Using the developed impedance models, the impacts of SCE and NSC, and the voltage and current control loop bandwidths, on system stability during faults are investigated. Additionally, since negative-sequence TVI (TVI-) is typically added along with its positive-sequence counterpart, which is often inductive, inductive and resistive TVI- are examined. The findings suggest that a higher voltage or current control loop bandwidth has a negative impact on system stability, while SCE and NSC largely reduce the stable range for voltage and current control loop bandwidth during faults, and that the severity of such impacts is determined by the particular SCE method. Furthermore, it is observed that inductive TVI- significantly degrades system stability, while resistive TVI- can enhance stability when suitable SCE methods are appropriately selected and designed. Matlab/Simulink electromagnetic transient simulations validate these analytical results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transient Stability-Enhancing Method for Grid-Forming Inverters Under Current Limiting

The primary controller of a grid-forming (GFM) inverter governs the internal reference voltage and angle, which enables the inverter to naturally synchronize and share power with the connected grid; however, during disturbances on the grid caused by, e.g., line faults, overloading, or frequency and phase shifts, a GFM inverter can be pushed into a current-limited operation to protect the device against thermal damage. This can lead to a windup of the internal reference frequency generated by the primary controller and cause a total loss of synchronism with the grid. Here, to make the primary controller of GFM inverters more robust against transient instability, this paper proposes a method that manipulates the reference signals governed by the primary controller by introducing the concept of fictitious power. The fictitious power counteracts the integrator windup in the primary controller, which enables the current-limited inverter to conceive a stable operating point. This method is benchmarked against five state-of-the-art GFM inverter stabilization methods to evaluate its stability-enhancing performance. Full-order electromagnetic-transient simulations and experimental results of a hardware inverter test setup validate the benefits of the method to improve the transient stability of GFM inverters in the face of grid disturbances.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Laplace-Domain Circuit Model for Fault and Stability Analysis Considering Unbalanced Topology

For systems subject to unbalanced faults, analytical model building for stability assessment is a challenging task. This letter presents a straightforward modeling approach. A generalized dynamic circuit representation is achieved by use of the Laplacian transform variable s . Here, we translate the voltage and current relationship at the fault location into the relationship of three subsystems. The final circuit model is an interconnected sequence network with impedances in the Laplace domain. This circuit can be directly converted from a steady-state sequence network. This modeling procedure is illustrated by an example case of an induction motor served by a grid through a series compensated line. Electromagnetic transient simulation results demonstrate that sub-synchronous oscillations can be mitigated when a single-line to ground fault is applied at the motor terminal. Stability analysis results based on the dynamic circuit corroborate the simulation results. What's more, the derived circuit effortlessly reveals why unbalance can enhance stability.

42 ENGINEERING↗

Criteria for Grid-Forming Inverters Transitioning Between Current Limiting Mode and Normal Operation

Here, this letter focuses on the fault recovery analysis of inverters using multi-loop droop based grid-forming control, taking into account different current limiting strategies. A criterion is proposed to determine when the inverter can exit the current limiting mode after fault clearance. The theoretical findings are verified through electromagnetic transient simulations using the direct (d)-axis priority-based current limiting method, circular current limiting method, and virtual impedance method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

GIST (Grid Impedance Scan Tool) [SWR-22-73]

NREL has developed GIST (Grid Impedance Scan Tool) to scan the impedance response of inverter-based resources such as land-based and offshore wind power plants, solar power plants, etc., from their electromagnetic transient simulation models to evaluate their impact on grid stability. GIST can scan impedance response of inverter-based resources from vendor-supplied black-box simulation models without requiring internal proprietary details, enabling detailed stability analysis of power systems with high levels of inverter-based generation.

Shah, Shahil↗

HiTEM

SAND2025-03438O HiTEM3d v1.0 is a user-friendly software designed to simulate how electromagnetic signals move through large geological environments, particularly around wellbores. It helps geophysicists and resource explorers understand subsurface conditions more effectively and affordably. By simplifying complex geological models, HiTEM3d allows users to visualize and analyze electromagnetic fields, making it easier to identify valuable resources like minerals or water. Its efficient processing capabilities ensure quick results, making it an essential tool for anyone involved in geophysical research or exploration. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Weiss, Chester [Sandia National Lab. (SNL-CA), Liv↗

Fundamental absorption bandwidth to thickness limit for transparent homogeneous layers

Abstract Past work has considered the analytic properties of the reflection coefficient for a metal-backed slab. The primary result established a fundamental relationship for the minimal layer thickness to bandwidth ratio achievable for an absorber. There has yet to be establishment of a similar relationship for non-metal-backed layers, and here we present the universal result based on the Kramers–Kronig relations. Our theory is validated with transfer matrix calculations of homogeneous materials, and full-wave numerical simulations of electromagnetic metamaterials. Our results place more general fundamental limits on absorbers and thus will be important for both fundamental and applied studies.

Padilla, Willie J.↗

FY19 FES Theory Performance Target (Final Report)

Understanding the relevant turbulent transport mechanisms at the edge of a high-performance tokamak is essential for predicting and optimizing the H-mode pedestal structure in future burning plasma devices. Global electromagnetic gyrokinetic simulations will be performed based on representative experimental pedestal scenarios in order to clarify which instabilities are most important for each of the particle and heat transport channels. Edge transport modeling will be performed in order to estimate and bound the particle and heat sources—e.g., the ionization density source and the atomic energy loss channels due to ionization, charge exchange, and radiation. Comparisons will be made with data from the DIII-D, JET, C-Mod and NSTX or MAST experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of the Protection Improvements for a Weak Grid Area With High Inverter-Based Resources (IBRs)

This project designs enhanced protection scheme for the real-world weak grid area with a high penetration of IBRs. As the existing protection schemes are originally designed for traditional synchronous machines, we first evaluate if the protection scheme will continue to operate reliably in systems with high levels of IBRs. Hardware relays are tested using a controller-hardware-in-the-loop setup. PSCAD electromagnetic transient simulation with IBR original equipment manufacturer black-box models is used to perform fault studies and generate COMTRADE data, which are replayed by a real-time digital simulator (RTDS) to feed input to the hardware relays. Three scenarios are analyzed: normal operation, an N-1 contingency, and an IBR-only scenario. The evaluation results reveal the following: 1) the protection scheme remains reliable under normal conditions and N-1 contingencies and 2) in IBR-only scenarios, differential protection (87L) continues to operate reliably, whereas local protection elements, such as distance and directional elements, fail because of the lack of regulated negative sequence current contributed by IBRs. Enhanced protection is designed to address the challenge of lack of negative sequence current from IBRs, including increased restraining factors a2 and k2 to block 32Q or using V instead QV ORDER for ground faults, enhanced mho distance element with voltage and phase angle supervision for L-L faults. The efficacy of enhanced protection logic is validated and proven to work reliably. Additionally, IEEE Std. 2800-2022 negative sequence current compliant GFL and GFM IBRs from another vendor are tested and proven to work reliably without need for enhanced logic. Therefore, this work provides valuable decision-making for utilities facing protection system challenges due to IBRs, either designing enhanced protection scheme or requesting their IBRs being IEEE Std. 2800-2022 compliant to produce regulated negative sequence current for protection relay to make correct decision.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Flexible Magnetic Polymer Composite Substrate with Ba 1.5 Sr 1.5 Z Hexaferrite Particles of VHF/Low UHF Patch Antennas for UAVs and Medical Implant Devices

Our goal is to fabricate flexible magnetic polymer composites as antenna substrates for very high frequency (VHF)/low ultra high frequency (UHF) antennas for unmanned aerial vehicles (UAVs) and medical devices. Magnetodielectric materials, which have permeability (μ) similar to permittivity (ε), have attracted great attention, because they facilitate miniaturization of microwave devices while keeping or enhancing electromagnetic characteristics. Mechanically millled Ba 1.5 Sr 1.5 Co 2 Fe 24 O 41 (Ba 1.5 Sr 1.5 Z) hexaferrite particles were used to increase permeability in the interesting frequency band. The microwave properties of Ba 1.5 Sr 1.5 Z composites were predicted and measured. Hansen’s zero-order analysis of antenna bandwidth and electromagnetic field simulation showed that the hexaferrite-based flexible composite could enhance a bandwidth and achieve the miniaturization of antennas as well. The magnetic antenna substrates can be a good solution to integrate antennas into the UAVs whose dimensions are comparable to or larger than communication wavelength.

36 MATERIALS SCIENCE↗

Evaluating Protection System Performance for a Real-World Weak Grid Area With High Inverter-Based Resources

This paper evaluates an existing protection scheme implemented in a real-world weak grid area with a high penetration of inverter-based resources (IBRs). The study aims to assess the reliability and adequacy of protection schemes originally designed for traditional synchronous machine systems and determine whether they can continue to operate reliably in systems with high levels of IBRs. Hardware relays are tested using a controller-hardware-in-the-loop setup. PSCAD electromagnetic transient simulation with an IBR original equipment manufacturer black-box model is used to perform fault studies and generate COMTRADE data, which are replayed by a realtime digital simulator (RTDS) to feed input to the hardware relays. Three scenarios are analyzed: normal operation, an N-1 contingency, and an IBR-only scenario. The evaluation results reveal the following: 1) the protection scheme remains reliable under normal conditions and N-1 contingencies and 2) in IBRonly scenarios, differential protection (87L) continues to operate reliably, whereas local protection elements, such as distance and directional elements, fail because of the lack of regulated negative sequence current contributed by IBRs. These findings provide utilities with valuable insights for improving their protection systems in high-IBRs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of electrical test procedures for qualification of spacecraft against EID. Volume 2: Review and specification of test procedures

A combined experimental and analytical program to develop system electrical test procedures for the qualification of spacecraft against damage produced by space-electron-induced discharges (EID) occurring on spacecraft dielectric outer surfaces is described. A review and critical evaluation of possible approaches to qualify spacecraft against space electron-induced discharges (EID) is presented. A variety of possible schemes to simulate EID electromagnetic effects produced in spacecraft was studied. These techniques form the principal element of a provisional, recommended set of test procedures for the EID qualification spacecraft. Significant gaps in our knowledge about EID which impact the final specification of an electrical test to qualify spacecraft against EID are also identified.

Wilkenfeld, J. M.↗

Heating of thermal helium in the equatorial magnetosphere - A simulation study

The heating of He(+) ions observed by the GEOS satellite at L of about seven starting from an initial anisotropic proton distribution is studied. A simulation of electromagnetic ion cyclotron waves in a plasma consisting of hot anisotropic protons, a dominant thermal hydrogen plasma, and a minority species of helium ions is utilized. It is shown that the thermal ions are heated to 100 times their initial temperature due to the growth of large-amplitude ion cyclotron waves. He(+) ions are heated mainly in the perpendicular direction, and they are heated more than cold H(+) ions. The He(+) ions are heated in a two-step process. First, they are set into oscillations by the growing wave until some of the ions reach a parallel velocity on the order of the resonant velocity; then, strong heating occurs.

Omura, Y.↗

Relativistic dispersion modifications to the cyclotron maser theory of planetary radio emissions

The effects of relativistic dispersion on the electron-cyclotron maser instability are investigated by linear theory, electromagnetic particle simulation, and quasilinear theory. When vsq/csq greater than or = omega pesq/Omega sq for the energetic electrons, the instability is localized just below k c/Omega e = 1, and the growth rate is strongly peaked for emission at 90 deg to the magnetic field. Saturation of the instability is due to perpendicular diffusion in momentum space, and the saturation level increases as omega pe/Omega e is decreased. Applications of the maser instability to the generation of the Earth's auroral kilometric radiation are discussed.

Pritchett, P. L.↗