Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electrical signals”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Space Technology for Patient Monitoring

A contract for the development of an astronaut monitoring system in the early days of the space program provided Mennen Medical, Inc. with a foundation in telemetry that led to the development of a computerized medical electronic system used by hospitals. Mennen was the first company to adopt solid state design in patient monitoring and to offer multipatient telemetry monitoring. Telemetry converts instrument data to electrical signals and relays them to a remote receiver where they are displayed. From a central station, a nurse can monitor several patients. Company products include VISTA systems and Horizon 2000 Monitor.

Source record↗

Vitamin D Investigation

The solar dosimeter, a spinoff from NASA solar cell technology, measures the amount of solar radiation to which its wearer is exposed. It was used in a University of Cincinnati Medical Center investigation into the effect of sunlight exposure on maintaining vitamin D status in infants. The infants were exposed to sunlight and records were kept by mothers. Each baby wore a solar dosimeter. The two circular "eyes" in the instrument are silicon photovoltaic detectors which collect solar energy, convert it to electric signals and transmit the charge to E-cells that record the charge by plating silver ions onto an electrode. The time required to plate the silver measures the radiation received. The University found the solar dosimeter to be very effective.

Source record↗

Automatic Welding System

Robotic welding has been of interest to industrial firms because it offers higher productivity at lower cost than manual welding. There are some systems with automated arc guidance available, but they have disadvantages, such as limitations on types of materials or types of seams that can be welded; susceptibility to stray electrical signals; restricted field of view; or tendency to contaminate the weld seam. Wanting to overcome these disadvantages, Marshall Space Flight Center, aided by Hayes International Corporation, developed system that uses closed-circuit TV signals for automatic guidance of the welding torch. NASA granted license to Combined Technologies, Inc. for commercial application of the technology. They developed a refined and improved arc guidance system. CTI in turn, licensed the Merrick Corporation, also of Nashville, for marketing and manufacturing of the new system, called the CT2 Optical Trucker. CT2 is a non-contracting system that offers adaptability to broader range of welding jobs and provides greater reliability in high speed operation. It is extremely accurate and can travel at high speed of up to 150 inches per minute.

Source record↗

Human Tissue Stimulator

Neurodyne Corporation Human Tissue Stimulator (HTS) is a totally implantable system used for treatment of chronic pain and involuntary motion disorders by electrical stimulation. It was developed by Pacesetter Systems, Inc. in cooperation with the Applied Physics Laboratory. HTS incorporates a nickel cadmium battery, telemetry and command systems technologies of the same type as those used in NASA's Small Astronomy Satellite-3 in microminiature proportions so that the implantable element is the size of a deck of cards. The stimulator includes a rechargeable battery, an antenna and electronics to receive and process commands and to report on its own condition via telemetry, a wireless process wherein instrument data is converted to electrical signals and sent to a receiver where signals are presented as usable information. The HTS is targeted to nerve centers or to particular areas of the brain to provide relief from intractable pain or arrest involuntary motion. The nickel cadmium battery can be recharged through the skin. The first two HTS units were implanted last year and have been successful. Extensive testing is required before HTS can be made available for general use.

Source record↗

Radiant Temperature Nulling Radiometer

A self-calibrating nulling radiometer for non-contact temperature measurement of an object, such as a body of water, employs a black body source as a temperature reference, an optomechanical mechanism, e.g., a chopper, to switch back and forth between measuring the temperature of the black body source and that of a test source, and an infrared detection technique. The radiometer functions by measuring radiance of both the test and the reference black body sources; adjusting the temperature of the reference black body so that its radiance is equivalent to the test source; and, measuring the temperature of the reference black body at this point using a precision contact-type temperature sensor, to determine the radiative temperature of the test source. The radiation from both sources is detected by an infrared detector that converts the detected radiation to an electrical signal that is fed with a chopper reference signal to an error signal generator, such as a synchronous detector, that creates a precision rectified signal that is approximately proportional to the difference between the temperature of the reference black body and that of the test infrared source. This error signal is then used in a feedback loop to adjust the reference black body temperature until it equals that of the test source, at which point the error signal is nulled to zero. The chopper mechanism operates at one or more Hertz allowing minimization of l/f noise. It also provides pure chopping between the black body and the test source and allows continuous measurements.

Robert Ryan↗

A laser microsurgical method of cell wall removal allows detection of large-conductance ion channels in the guard cell plasma membrane

Application of patch clamp techniques to higher-plant cells has been subject to the limitation that the requisite contact of the patch electrode with the cell membrane necessitates prior enzymatic removal of the plant cell wall. Because the wall is an integral component of plant cells, and because cell-wall-degrading enzymes can disrupt membrane properties, such enzymatic treatments may alter ion channel behavior. We compared ion channel activity in enzymatically isolated protoplasts of Vicia faba guard cells with that found in membranes exposed by a laser microsurgical technique in which only a tiny portion of the cell wall is removed while the rest of the cell remains intact within its tissue environment. "Laser-assisted" patch clamping reveals a new category of high-conductance (130 to 361 pS) ion channels not previously reported in patch clamp studies on plant plasma membranes. These data indicate that ion channels are present in plant membranes that are not detected by conventional patch clamp techniques involving the production of individual plant protoplasts isolated from their tissue environment by enzymatic digestion of the cell wall. Given the large conductances of the channels revealed by laser-assisted patch clamping, we hypothesize that these channels play a significant role in the regulation of ion content and electrical signalling in guard cells.

Non-NASA Center↗

New Gear Transmission Error Measurement System Designed

The prime source of vibration and noise in a gear system is the transmission error between the meshing gears. Transmission error is caused by manufacturing inaccuracy, mounting errors, and elastic deflections under load. Gear designers often attempt to compensate for transmission error by modifying gear teeth. This is done traditionally by a rough "rule of thumb" or more recently under the guidance of an analytical code. In order for a designer to have confidence in a code, the code must be validated through experiment. NASA Glenn Research Center contracted with the Design Unit of the University of Newcastle in England for a system to measure the transmission error of spur and helical test gears in the NASA Gear Noise Rig. The new system measures transmission error optically by means of light beams directed by lenses and prisms through gratings mounted on the gear shafts. The amount of light that passes through both gratings is directly proportional to the transmission error of the gears. A photodetector circuit converts the light to an analog electrical signal. To increase accuracy and reduce "noise" due to transverse vibration, there are parallel light paths at the top and bottom of the gears. The two signals are subtracted via differential amplifiers in the electronics package. The output of the system is 40 mV/mm, giving a resolution in the time domain of better than 0.1 mm, and discrimination in the frequency domain of better than 0.01 mm. The new system will be used to validate gear analytical codes and to investigate mechanisms that produce vibration and noise in parallel axis gears.

Oswald, Fred B.↗

Multifrequency Ultra-High Resolution Miniature Scanning Microscope Using Microchannel And Solid-State Sensor Technologies And Method For Scanning Samples

A miniature, ultra-high resolution, and color scanning microscope using microchannel and solid-state technology that does not require focus adjustment. One embodiment includes a source of collimated radiant energy for illuminating a sample, a plurality of narrow angle filters comprising a microchannel structure to permit the passage of only unscattered radiant energy through the microchannels with some portion of the radiant energy entering the microchannels from the sample, a solid-state sensor array attached to the microchannel structure, the microchannels being aligned with an element of the solid-state sensor array, that portion of the radiant energy entering the microchannels parallel to the microchannel walls travels to the sensor element generating an electrical signal from which an image is reconstructed by an external device, and a moving element for movement of the microchannel structure relative to the sample. Discloses a method for scanning samples whereby the sensor array elements trace parallel paths that are arbitrarily close to the parallel paths traced by other elements of the array.

Wang, Yu↗

Laserfax

The photo shows an Associated Press technician receiving a photograph prepared by means of a high speed, high resolution facsimile system known as Laserfax, so called because it employs a laser beam to scan the photo being sent. Laser scanning data is converted to electrical signals and transmitted to news bureaus within the Associated Press network via microwave radio or telephone lines. At the other end, another laser sweeps reconverted imagery onto a special, light-sensitive, dry silver paper. The paper is then heat processed to reproduce the photograph. Manufactured by Harris Electronics Systems Inc., Melbourne, Florida, Laserfax incorporates NASA thermal control coating technology developed by Jet Propulsion Laboratory for use on spacecraft antennas; the coatings block absorption of solar radiation which would interfere with the antenna's proper operation. Harris Electronics Systems, originally Radiation, Inc., reused the NASA technology in development of Laserfax. A NASA technical support package provided information about the thermal properties that could be expected of various coatings for the facsimile system's paper rollers; this information served as a design base for the infrared heat source used in developing the photo. Although relatively new, Laserfax is in extensive service. It is manufactured in several models. One of them is the type used by the Associated Press, its news bureaus and affiliated newspapers, radio and television stations. Other models have been sold in large numbers to law enforcement agencies for transmitting high quality fingerprints and identification photos. Laserfax is also in service with the National Weather Service, which converts satellite imagery to weather photographs and relays them to local weather stations, television stations, newspapers and airlines.

Source record↗

Patient Monitoring

In photo above, the electrocardiogram of a hospitalized patient is being transmitted by telemetry. Widely employed in space operations, telemetry is a process wherein instrument data is converted to electrical signals and sent to a receiver where the signals are reconverted to usable information. In this instance, heart readings are picked up by the electrode attached to the patient's body and delivered by wire to the small box shown, which is a telemetry transmitter. The signals are relayed wirelessly to the console in the background, which converts them to EKG data. The data is displayed visually and recorded on a printout; at the same time, it is transmitted to a central control station (upper photo) where a nurse can monitor the condition of several patients simultaneously. The Patient Monitoring System was developed by SCI Systems, Inc., Huntsville, Alabama, in conjunction with Abbott Medical Electronics, Houston, Texas. In developing the system, SCI drew upon its extensive experience as a NASA contractor. The company applied telemetry technology developed for the Saturn launch vehicle and the Apollo spacecraft; instrumentation technology developed for heart, blood pressure and sleep monitoring of astronauts aboard NASA's Skylab long duration space station; and communications technology developed for the Space Shuttle.

Source record↗

Voice Controlled Wheelchair

Michael Condon, a quadraplegic from Pasadena, California, demonstrates the NASA-developed voice-controlled wheelchair and its manipulator, which can pick up packages, open doors, turn a TV knob, and perform a variety of other functions. A possible boon to paralyzed and other severely handicapped persons, the chair-manipulator system responds to 35 one-word voice commands, such as "go," "stop," "up," "down," "right," "left," "forward," "backward." The heart of the system is a voice-command analyzer which utilizes a minicomputer. Commands are taught I to the computer by the patient's repeating them a number of times; thereafter the analyzer recognizes commands only in the patient's particular speech pattern. The computer translates commands into electrical signals which activate appropriate motors and cause the desired motion of chair or manipulator. Based on teleoperator and robot technology for space-related programs, the voice-controlled system was developed by Jet Propulsion Laboratory under the joint sponsorship of NASA and the Veterans Administration. The wheelchair-manipulator has been tested at Rancho Los Amigos Hospital, Downey, California, and is being evaluated at the VA Prosthetics Center in New York City.

Source record↗

The Lunar Orbiter: A Spacecraft to Advance Lunar Exploration

The film describes the Lunar Orbiter's mission to photograph landing areas on the Moon. The Orbiter will be launched from Cape Kennedy using an Atlas Agena booster rocket. Once it is boosted in a trajectory toward the Moon, the Orbiter will deploy two-way earth communication antennas and solar panels for electricity. Attitude control jets will position the solar panels toward the sun and a tracker for a fix on its navigational star. The Orbiter will be put in an off-center orbit around the Moon where it will circle from four to six days. Scientists on Earth will study the effects of the Moon's gravitational field on the spacecraft, then the orbit will be lowered to 28 miles above the Moon's surface. Engineers will control the Orbiter manually or by computer to activate two camera lenses. The cameras will capture pictures of 12,000 square miles of lunar surface in 25 and 400 square mile increments. Pictures will be sent back to Earth using solar power to transmit electrical signals. The signals will be received by antennas at Goldstone, CA, and in Australia and Spain. Incoming photographic data will be electronically converted and processed to produce large-scale photographic images. The mission will be directed from the Space Flight Operations Facility in Pasadena, CA by NASA and Boeing engineers. After the photographic mission, the Orbiter will continue to circle the Moon providing information about micrometeoroids and radiation in the vicinity.

Source record↗

Overview of the LISA Phasemeter

The LISA phasemeter is required to measure the phase of an electrical signal with an error less than 3 (micro)cycles/pHz over times scales from 1 to 1000 seconds. This phase sensitivity must be achieved in the presence of laser phase fluctuations 108 times larger than the target sensitivity. Other challenging aspects of the measurement are that the heterodyne frequency varies from 2 to 20 MHz and the signal contains multiple frequency tones that must be measured. The phasemeter architecture uses high-speed analog to digital conversion followed by a digital phase locked loop. An overview of the phasemeter architecture is presented along with results for the breadboard LISA Phasemeter demonstrating that critical requirements are met.

offset phase locks↗

Sensor tip for a robotic gripper and method of manufacture

A sensor tip (10) for use in a robotic hand has a three-dimensional compliant elastomeric body (12) with an outer boundary (22) having a circular base (24) and a convex surface (26) extending therefrom. Four strain transducers (14, 16, 18, and 20) produce electrical signals indicative of the strain at various positions near the boundary of the elastomeric body (12) resulting from forces exerted upon the sensor tip (10) by an object which the robotic hand is manipulating. The transducers (14, 16, 18, and 20) are positioned about the convex surface (26) so as to produce signals that may be decoupled to determine the normal and tangential forces and the applied torque. A buffer amplifier circuit (34), one for each of the transducers (14, 16, 18, and 20), receives the signals and provides quasi-steady state force information. The circuit (34) connects the respective transducer (40) in a feedback loop around an amplifier (36) and has desirable attributes for static charge buffering. The sensor tip (10) is calibrated to determine proportionality constants for the decoupling algorithm for use of a force delivering system (60), which uses voice coils (74) to apply a force that is linearly related to the current introduced to each of the coils (74). A method of manufacture of the sensor tip (10) results in improved bonding between the transducers (14, 16, 18, and 20) and the elastomeric body (12) for better performance and longer life of the sensor tip (10).

Lorenz, Robert D.↗

Automated mass spectrometer analysis system

An automated mass spectrometer analysis system is disclosed, in which samples are automatically processed in a sample processor and converted into volatilizable samples, or their characteristic volatilizable derivatives. Each volatilizable sample is sequentially volatilized and analyzed in a double focusing mass spectrometer, whose output is in the form of separate ion beams all of which are simultaneously focused in a focal plane. Each ion beam is indicative of a different sample component or different fragments of one or more sample components and the beam intensity is related to the relative abundance of the sample component. The system includes an electro-optical ion detector which automatically and simultaneously converts the ion beams, first into electron beams which in turn produce a related image which is transferred to the target of a vilicon unit. The latter converts the images into electrical signals which are supplied to a data processor, whose output is a list of the components of the analyzed sample and their abundances. The system is under the control of a master control unit, which in addition to monitoring and controlling various power sources, controls the automatic operation of the system under expected and some unexpected conditions and further protects various critical parts of the system from damage due to particularly abnormal conditions.

Kuppermann, Aron↗

Method and apparatus for determining the physical properties of materials using dynamic light scattering techniques

A system for determining the physical properties of materials through the use of dynamic light scattering is disclosed. The system includes a probe, a laser source for directing a laser beam into the probe, and a photodetector for converting scattered light detected by the probe into electrical signals. The probe includes at least one optical fiber connected to the laser source and a second optical fiber connected to the photodetector. Each of the fibers may adjoin a gradient index microlens which is capable of providing a collimated laser beam into a scattering medium. The position of the second optical fiber with respect to the optical axis of the probe determines whether homodyne or self-beating detection is provided. Self-beating detection may be provided without a gradient index microlens. This allows a very small probe to be constructed which is insertable through a hypodermic needle or the like into a droplet extending from such a needle. A method of detecting scattered light through the use of a collimated, Gaussian laser beam is also provided. A method for controlling the waist and divergence of the optical field emanating from the free end of an optical fiber is also provided.

Dhadwal, Harbans S.↗

Stereo optical guidance system for control of industrial robots

A device for the generation of basic electrical signals which are supplied to a computerized processing complex for the operation of industrial robots. The system includes a stereo mirror arrangement for the projection of views from opposite sides of a visible indicia formed on a workpiece. The views are projected onto independent halves of the retina of a single camera. The camera retina is of the CCD (charge-coupled-device) type and is therefore capable of providing signals in response to the image projected thereupon. These signals are then processed for control of industrial robots or similar devices.

Powell, Bradley W.↗

Sensor tip for a robotic gripper and method of manufacture

A sensor tip (10) for use in a robotic hand has a three-dimensional compliant elastomeric body (12) with an outer boundary (22) having a circular base (24) and a convex surface (26) extending therefrom. Four strain transducers (14, 16, 18, and 20) produce electrical signals indicative of the strain at various positions near the boundary of the elastomeric body (12) resulting from forces exerted upon the sensor tip (10) by an object which the robotic hand is manipulating. The transducers (14, 16, 18, and 20) are positioned about the convex surface (26) so as to produce signals that may be decoupled to determine the normal and tangential forces and the applied torque. A buffer amplifier circuit (34), one for each of the transducers (14, 16, 18, and 20), receives the signals and provides quasi-steady state force information. The circuit (34) connects the respective transducer (40) in a feedback loop around an amplifier (36) and has desirable attributes for static charge buffering. The sensor tip (10) is calibrated to determine proportionality constants for the decoupling algorithm for use of a force delivering system (60), which uses voice coils (74) to apply a force that is linearly related to the current introduced to each of the coils (74). A method of manufacture of the sensor tip (10) results in improved bonding between the transducers (14, 16, 18, and 20) and the elastomeric body (12) for better performance and longer life of the sensor tip (10).

Lorenz, Robert D.↗