Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ERROR DETECTING CODE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

A satellite mobile communication system based on Band-Limited Quasi-Synchronous Code Division Multiple Access (BLQS-CDMA)

Discussed here is a new approach to code division multiple access applied to a mobile system for voice (and data) services based on Band Limited Quasi Synchronous Code Division Multiple Access (BLQS-CDMA). The system requires users to be chip synchronized to reduce the contribution of self-interference and to make use of voice activation in order to increase the satellite power efficiency. In order to achieve spectral efficiency, Nyquist chip pulse shaping is used with no detection performance impairment. The synchronization problems are solved in the forward link by distributing a master code, whereas carrier forced activation and closed loop control techniques have been adopted in the return link. System performance sensitivity to nonlinear amplification and timing/frequency synchronization errors are analyzed.

Degaudenzi, R.↗

Towards Realistic and High Fidelity Models for Nuclear Reactor Power Synthesis Simulation with Self-Powered Neutron Detectors

As presented in this report, a weighting function–based inferencing method is being applied to synthesize the power distribution in next-generation and university research reactors based on simulated self power neutron detector (SPND) responses. The overall goal is to assess the impacts of sensor uncertainty and true power distribution perturbations on the error in the synthesized power distribution. Regarding sensor uncertainty, the NuScale Small Modular Reactor (SMR) and the Westinghouse AP1000 serve as testbeds for analyzing the impact of varying the sensor uncertainty, as well as varying the number of sensors per sensor string in the reactor core. The reactor models are informed by Monte Carlo N-Particle (MCNP) neutron flux tallies. For the NuScale SMR and Westinghouse AP1000, the SPND response functions (i.e., the response of the SPNDs to individual segments of fuel) were determined homogeneously. Regarding an analysis of power distribution perturbation detection, the Texas A&M Testing, Research, Isotopes, General Atomics Reactor (TAMU TRIGA) reactor was used as a demonstration case with one particular arrangement of SPNDs; the response functions for this reactor model were determined heterogeneously, making this a uniquely high-fidelity demonstration of perturbation detection. Finally, SPND models generated in the Geometry and Tracking 4 (Geant4) code have been generated and tested for comparison with traditionally implemented analytical SPND models, with the intent for Geant4 integration with the full methodological framework. SPND current outputs as a function of distance from some fuel assembly segment in the NuScale SMR are compared with the analytically determined currents. Results from the sensor uncertainty simulations for the NuScale SMR and AP1000 indicate that the average error in the inferred power distribution on the fuel assembly segment level is reasonably low, being slightly less than the random uncertainty applied to all respective SPNDs in both cores. For example, if all SPNDs in the core have a random uncertainty of 5%, then the corresponding fuel assembly segment level error (i.e. difference between the true and inferred local power) is ~2–3%. However, the maximum error in the inferred power distribution on the fuel assembly segment level can be considerably high (>15%) when SPND random uncertainties start to exceed ~3%. In general, the average and maximum errors in the inferred power distribution were slightly higher in the AP1000 as opposed to the NuScale SMR for the sensor string configurations considered herein. Another result determined from analysis of the sensor uncertainty simulations was that increasing the number of SPNDs per string does not clearly reduce inferred power distribution error and can in fact make the error large in some cases; however, this assessment may skewed due to imposed iteration limits. Results from the perturbation detection demonstration using the high-fidelity TAMU TRIGA model indicate that, given the arrangement of 17 SPND strings and 4 SPNDs per string considered herein, there is a clear, provable ability to infer a localized Gaussian-type peak perturbation in the 3D power distribution. Such a perturbation was detected with an average fuel assembly segment level error of 0.19%, and the general visualization of the detected perturbation clearly indicates that the magnitude and shape were appropriately resolved. Finally, the electrical current output generated by the Geant4 modeled SPND indicates significant magnitude differences than the analytically modeled SPND, demonstrating the need for accurate SPND models which account for finite sensor geometry effects to inform the power synthesis work described herein.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Arithmetic algorithms for error-coded operands.

Arithmetic algorithms for separate and nonseparate codes are considered. The nonseparate AN code is formed when an uncoded operand X is multiplied by the check modulus A to give the coded operand AX. The separate codes are the residue code, and the inverse-residue code, which has significant advantages in fault detection of repeated-use faults. A set of algorithms for low-cost AN-coded operands is discussed together with questions of their implementation in a byte-organized arithmetic processor. Algorithms for inverse-residue coded operands of the STAR computer are also examined.

Avizienis, A.↗

Executable assertions and flight software

It is pointed out that executable assertions can be used for dynamic testing of software. An executable assertion is a logical statement about the variables or a block of code. If there is no error during execution then the assertion statement results in a true value. Assertions are useful for testing purposes throughout the lifecycle of software. They can be used for validation during the design phase, and for exception handling and error detection during the operation phase. The present investigation has the objective to study the use of executable assertions for testing flight software. Attention is given to details regarding executable assertions, the digital flight control system, testing flight software, and preliminary experimental results.

Mahmood, A.↗

Fast Correction For Doppler In MDPSK Signals

Detector of multiple differential phase-shift-keyed (MDPSK) signals designed to effect combination of open-loop estimation of frequency and differential detection of digital modulation. Improved design expected to decrease probability of bit errors in situations in which carrier frequency uncertain and signals transmitted in bursts too short to allow closed-loop tracking of carrier frequency - for example, in transmission of digitally-coded voice signals in land-mobile/satellite communications at ultra-high frequencies.

Simon, M. K.↗

SENSITIVITY OF BLIND PULSAR SEARCHES WITH THE FERMI LARGE AREA TELESCOPE

We quantitatively establish the sensitivity to the detection of young to middle-aged, isolated, gamma-ray pulsars through blind searches of Fermi Large Area Telescope (LAT) data using a Monte Carlo simulation. We detail a sensitivity study of the time-differencing blind search code used to discover gamma-ray pulsars in the first year of observations. We simulate 10,000 pulsars across a broad parameter space and distribute them across the sky. We replicate the analysis in the Fermi LAT First Source Catalog to localize the sources, and the blind search analysis to find the pulsars. We analyze the results and discuss the effect of positional error and spin frequency on gamma-ray pulsar detections. Finally, we construct a formula to determine the sensitivity of the blind search and present a sensitivity map assuming a standard set of pulsar parameters. The results of this study can be applied to population studies and are useful in characterizing unidentified LAT sources.

79 ASTRONOMY AND ASTROPHYSICS↗

WE-D-BRA-04: Online 3D EPID-Based Dose Verification for Optimum Patient Safety

Purpose: To develop an online 3D dose verification tool based on EPID transit dosimetry to ensure optimum patient safety in radiotherapy treatments. Methods: A new software package was developed which processes EPID portal images online using a back-projection algorithm for the 3D dose reconstruction. The package processes portal images faster than the acquisition rate of the portal imager (∼ 2.5 fps). After a portal image is acquired, the software seeks for “hot spots” in the reconstructed 3D dose distribution. A hot spot is in this study defined as a 4 cm{sup 3} cube where the average cumulative reconstructed dose exceeds the average total planned dose by at least 20% and 50 cGy. If a hot spot is detected, an alert is generated resulting in a linac halt. The software has been tested by irradiating an Alderson phantom after introducing various types of serious delivery errors. Results: In our first experiment the Alderson phantom was irradiated with two arcs from a 6 MV VMAT H&N treatment having a large leaf position error or a large monitor unit error. For both arcs and both errors the linac was halted before dose delivery was completed. When no error was introduced, the linac was not halted. The complete processing of a single portal frame, including hot spot detection, takes about 220 ms on a dual hexacore Intel Xeon 25 X5650 CPU at 2.66 GHz. Conclusion: A prototype online 3D dose verification tool using portal imaging has been developed and successfully tested for various kinds of gross delivery errors. The detection of hot spots was proven to be effective for the timely detection of these errors. Current work is focused on hot spot detection criteria for various treatment sites and the introduction of a clinical pilot program with online verification of hypo-fractionated (lung) treatments.

60 APPLIED LIFE SCIENCES↗

Targeting safety improvements through identification of incident origination and detection in a near-miss incident learning system

Purpose: Radiation treatment planning involves a complex workflow that has multiple potential points of vulnerability. This study utilizes an incident reporting system to identify the origination and detection points of near-miss errors, in order to guide their departmental safety improvement efforts. Previous studies have examined where errors arise, but not where they are detected or applied a near-miss risk index (NMRI) to gauge severity. Methods: From 3/2012 to 3/2014, 1897 incidents were analyzed from a departmental incident learning system. All incidents were prospectively reviewed weekly by a multidisciplinary team and assigned a NMRI score ranging from 0 to 4 reflecting potential harm to the patient (no potential harm to potential critical harm). Incidents were classified by point of incident origination and detection based on a 103-step workflow. The individual steps were divided among nine broad workflow categories (patient assessment, imaging for radiation therapy (RT) planning, treatment planning, pretreatment plan review, treatment delivery, on-treatment quality management, post-treatment completion, equipment/software quality management, and other). The average NMRI scores of incidents originating or detected within each broad workflow area were calculated. Additionally, out of 103 individual process steps, 35 were classified as safety barriers, the process steps whose primary function is to catch errors. The safety barriers which most frequently detected incidents were identified and analyzed. Finally, the distance between event origination and detection was explored by grouping events by the number of broad workflow area events passed through before detection, and average NMRI scores were compared. Results: Near-miss incidents most commonly originated within treatment planning (33%). However, the incidents with the highest average NMRI scores originated during imaging for RT planning (NMRI = 2.0, average NMRI of all events = 1.5), specifically during the documentation of patient positioning and localization of the patient. Incidents were most frequently detected during treatment delivery (30%), and incidents identified at this point also had higher severity scores than other workflow areas (NMRI = 1.6). Incidents identified during on-treatment quality management were also more severe (NMRI = 1.7), and the specific process steps of reviewing portal and CBCT images tended to catch highest-severity incidents. On average, safety barriers caught 46% of all incidents, most frequently at physics chart review, therapist’s chart check, and the review of portal images; however, most of the incidents that pass through a particular safety barrier are not designed to be capable of being captured at that barrier. Conclusions: Incident learning systems can be used to assess the most common points of error origination and detection in radiation oncology. This can help tailor safety improvement efforts and target the highest impact portions of the workflow. The most severe near-miss events tend to originate during simulation, with the most severe near-miss events detected at the time of patient treatment. Safety barriers can be improved to allow earlier detection of near-miss events.

60 APPLIED LIFE SCIENCES↗

Laying the Foundation for a Predictive Theory of Electroweak Nuclear Phenomena

Reliable model-independent predictions of nuclear processes such as beta-decay and neutrinonucleus scattering are important for many fundamental science and mission-related investigations; For example, accurate descriptions of as beta-decay are required for modeling the anti-neutrino spectrum of nuclear reactor, whether for trying to detect new physics such as sterile neutrinos, or remotely identifying the purpose of that reactor. For these activities, we need accurate calculations, as well as careful and thorough analyses of theoretical error and uncertainty in the underlying models and the many-body methods and codes used in solving that model. Unfortunately, modern theoretical calculations of these processes are inadequate for this task. At the heart of this inadequacy is the interaction between nucleons and other particles known as nuclear currents. Historically, descriptions of nuclear currents took into account only the simplest of particle interactions. Recently, the development of an effective field theory known as chiral EFT has been used to derive large corrections to these particle interactions. However, the complex nature of these corrections inhibited their use in ab initio methods of predicting nuclear processes. We developed a novel method to address these complexities and applied it in a series of benchmark and demonstrative calculations using state-of-the-art quantum few-nucleon solvers. Specifically, we studied the role of two-nucleon currents in electroweak processes using light nuclei (i.e., nuclei containing fewer than five nucleons) as a workbench to compute these processes and quantify their uncertainties using Bayesian extensions of the EFT.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Safeguards Envelope: The First Steps

The possibility exists for real time accountancy and assay of nuclear materials as they move through a reprocessing facility. This project aims to establish working parameters and local figures of merit to identify possible diversion in real time with minimal operational impact. Factors such as pH, NOX gas concentration, flow speeds and radiation fields are rarely taken into account in safeguards methodologies and will be included to increase the confidence of location and assay of nuclear materials. An adaptable, real data model is being created of the contactors of the Advanced Fuel Cycle Facility and will be analyzed using the appropriate modeling codes. This model will then be subjected to three, diversion scenarios and a figure of merit methodology will be utilized to create the operational parameters under which these diversion scenarios would be detected. This analysis for figure of merit methodology will include statistical fluctuations, operator error, and a rudimentary analysis of transient conditions. The long term goal of the project includes expansion universally over the plant, methods of detection without requiring access to proprietary information, and an evaluation of the requirements for future figure of merit methodologies.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Development of a novel quality assurance system based on rolled-up and rolled-out radiochromic films in volumetric modulated arc therapy

Purpose: To develop a cylindrical phantom with rolled-up radiochromic films and dose analysis software in the rolled-out plane for quality assurance (QA) in volumetric modulated arc therapy (VMAT). Methods: The phantom consists of an acrylic cylindrical body wrapped with radiochromic film inserted into an outer cylindrical shell of 5 cm thickness. The rolled-up films with high spatial resolution enable detection of specific dose errors along the arc trajectory of continuously irradiated and modulated beams in VMAT. The developed dose analysis software facilitates dosimetric evaluation in the rolled-up and rolled-out planes of the film; the calculated doses on the corresponding points where the rolled-up film was placed were reconstructed into a rectangular dose matrix equivalent to that of the rolled-out plane of the film. The VMAT QA system was implemented in 3 clinical cases of prostate, nasopharynx, and pelvic metastasis. Each calculated dose on the rolled-out plane was compared with measurement values by modified gamma evaluation. Detected positions of dose disagreement on the rolled-out plane were also distinguished in cylindrical coordinates. The frequency of error occurrence and error distribution were summarized in a histogram and in an axial view of rolled-up plane to intuitively identify the corresponding positions of detected errors according to the gantry angle. Results: The dose matrix reconstructed from the developed VMAT QA system was used to verify the measured dose distribution along the arc trajectory. Dose discrepancies were detected on the rolled-out plane and visualized on the calculated dose matrix in cylindrical coordinates. The error histogram obtained by gamma evaluation enabled identification of the specific error frequency at each gantry angular position. The total dose error occurring on the cylindrical surface was in the range of 5%-8% for the 3 cases. Conclusions: The developed system provides a practical and reliable QA method to detect dosimetric errors according to the gantry angle. Film dosimetry based on rolled-up and rolled-out techniques leads to dose verification in the subspaces of the 3D dose volume. The system can be employed as an alternative tool to detect the pitfalls of planar dose verification.

61 RADIATION PROTECTION AND DOSIMETRY↗

Spatiotemporally Adaptive Compression for Scientific Dataset with Feature Preservation – A Case Study on Simulation Data with Extreme Climate Events Analysis

Scientific discoveries are increasingly constrained by limited storage space and I/O capacities. For time-series simulations and experiments, their data often need to be decimated over timesteps to accommodate storage and I/O limitations. In this paper, we propose a technique that addresses storage costs while improving post-analysis accuracy through spatiotemporal adaptive, error-controlled lossy compression. We investigate the trade-off between data precision and temporal output rates, revealing that reducing data precision and increasing timestep frequency lead to more accurate analysis outcomes. Additionally, we integrate spatiotemporal feature detection with data compression and demonstrate that performing adaptive error-bounded compression in higher dimensional space enables greater compression ratios, leveraging the error propagation theory of a transformation-based compressor. To evaluate our approach, we conduct experiments using the well-known E3SM climate simulation code and apply our method to compress variables used for cyclone tracking. Our results show a significant reduction in storage size while enhancing the quality of cyclone tracking analysis, both quantitatively and qualitatively, in comparison to the prevalent timestep decimation approach. Compared to three state-of-the-art lossy compressors lacking feature preservation capabilities, our adaptive compression framework improves perfectly matched cases in TC tracking by 26.4-51.3% at medium compression ratios and by 77.3-571.1% at large compression ratios, with a merely 5–11% computational overhead.

Gong, Qian↗

Generalised form factor dark matter in the Sun

We study the effects of energy transport in the Sun by asymmetric dark matter with momentum and velocity-dependent interactions, with an eye to solving the decade-old Solar Abundance Problem. We study effective theories where the dark matter-nucleon scattering cross-section goes as v{sub rel}{sup 2n} and q{sup 2n} with n=−1,0,1 or 2, where v{sub rel} is the dark matter-nucleon relative velocity and q is the momentum exchanged in the collision. Such cross-sections can arise generically as leading terms from the most basic nonstandard DM-quark operators. We employ a high-precision solar simulation code to study the impact on solar neutrino rates, the sound speed profile, convective zone depth, surface helium abundance and small frequency separations. We find that the majority of models that improve agreement with the observed sound speed profile and depth of the convection zone also reduce neutrino fluxes beyond the level that can be reasonably accommodated by measurement and theory errors. However, a few specific points in parameter space yield a significant overall improvement. A 3–5 GeV DM particle with σ{sub SI}∝q{sup 2} is particularly appealing, yielding more than a 6σ improvement with respect to standard solar models, while being allowed by direct detection and collider limits. We provide full analytical capture expressions for q- and v{sub rel}-dependent scattering, as well as complete likelihood tables for all models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance of the ICAO standard core service modulation and coding techniques

Aviation binary phase shift keying (A-BPSK) is described and simulated performance results are given that demonstrate robust performance in the presence of hardlimiting amplifiers. The performance of coherently-detected A-BPSK with rate 1/2 convolutional coding are given. The performance loss due to the Rician fading was shown to be less than 1 dB over the simulated range. A partially coherent detection scheme that does not require carrier phase recovery was described. This scheme exhibits similiar performance to coherent detection, at high bit error rates, while it is superior at lower bit error rates.

Lodge, John↗

SU-E-T-442: Sensitivity of Quality Assurance Tools to Delivery Errors On a Magnetic Resonance-Imaging Guided Radiation Therapy (MR-IGRT) System

Purpose: To test the sensitivity of the quality assurance (QA) tools actively used on a clinical MR-IGRT system for potential delivery errors. Methods: Patient-specific QA procedures have been implemented for a commercially available Cobalt-60 MR-IGRT system. The QA tools utilized were a MR-compatible cylindrical diode-array detector (ArcCHECK) with a custom insert which positions an ionization chamber (Exradin A18) in the middle of the device, as well as an in-house treatment delivery verification program. These tools were tested to investigate their sensitivity to delivery errors. For the ArcCHECK and ion chamber, a baseline was established with a static field irradiation to a known dose. Variations of the baseline were investigated which included rotated gantry, altered field size, directional shifts, and different delivery time. In addition, similar variations were tested with the automated delivery verification program that compared the treatment parameters in the machine delivery logs to the ones in the plan. To test the software, a 3-field conformal plan was generated as the baseline. Results: ArcCHECK noted at least a 13% decrease in passing rate from baseline in the following scenarios: gantry rotation of 1 degree from plan, 5mm change in field size, 2mm lateral shift, and delivery time decrease. Ion chamber measurements remained consistent for these variations except for the 5 second decrease in delivery time scenario which resulted in an 8% difference from baseline. The delivery verification software was able to detect and report the simulated errors such as when the gantry was rotated by 0.6 degrees, the beam weighting was changed by a percent, a single multileaf collimator was moved by 1cm, and the dose was changed from 2 to 1.8Gy. Conclusion: The results show that the current tools used for patient specific QA are capable of detecting small errors in RT delivery with presence of magnetic field.

60 APPLIED LIFE SCIENCES↗

SU-C-BRD-06: Sensitivity Study of An Automated System to Acquire and Analyze EPID Exit Dose Images

Purpose: The dosimetric consequences of errors in patient setup or beam delivery and anatomical changes are not readily known. A new product, PerFRACTION (Sun Nuclear Corporation), is designed to detect these errors by comparing the EPID exit dose image from each field of each fraction to those from baseline fraction images. This work investigates the sensitivity of PerFRACTION to detect the deviation of induced errors in a variety of realistic scenarios. Methods: Eight plans were created mimicking potential delivery or setup errors. The plans consisted of a nominal field and the field with an induced error. These were used to irradiate the EPID simulating multiple fractions with and without the error. Integrated EPID images were acquired in clinical mode and saved in ARIA. PerFRACTION automatically pulls the images into its database and performs the user defined comparison. In some cases, images were manually pushed to PerFRACTION. We varied the distance-to-agreement or dose tolerance until PerFRACTION showed failing pixels in the affected region and recorded the values. We induced errors of 1mm and greater in jaw, MLC, and couch position, 2 degree collimation rotation (patient yaw), and 0.5% to 1.5% in machine output. Both static and arc fields with the rails in or out were also acquired and compared. Results: PerFRACTION detected position errors of the jaws, MLC, and couch with an accuracy of better than 0.5 mm, and 0.2 degrees for collimator and gantry error. PerFRACTION detected a machine output error within 0.2% and detected the change in rail position. Conclusion: A new automated system for monitoring daily treatments for machine or patient variations from the first fraction using integrated EPID images was found to be sensitive enough to detect small positional, angular, and dosimetric errors within 0.5mm, 0.2 degrees, and 0.2%, respectively. Sun Nuclear Corporation has provided a software license for the product described.

60 APPLIED LIFE SCIENCES↗

Final Draft of RACER Audit

This document describes the approach Waste and Environmental Services - Environmental Data and Analysis plans to take to resolve the issues presented in a recent audit of the WES-EDA Environmental Database relative to the RACER database. A majority of the issues discovered in the audit will be resolved in May 2011 when the WES-EDA Environmental Database, along with other LANL databases, are integrated and moved to a new vendor providing an Environmental Information Management (EIM) system that allows reporting capabilities for all users directly from the database. The EIM system will reside in a publicly accessible LANL cloud-based software system. When this transition occurs, the data quality, completeness, and access will change significantly. In the remainder of this document, this new structure will be referred to as the LANL Cloud System In general, our plan is to address the issues brought up in this audit in three ways: (1) Data quality issues such as units and detection status, which impinge upon data usability, will be resolved as soon possible so that data quality is maintained. (2) Issues requiring data cleanup, such as look up tables, legacy data, locations, codes, and significant data discrepancies, will be addressed as resources permit. (3) Issues associated with data feed problems will be eliminated by the LANL Cloud System, because there will be no data feed. As discussed in the paragraph above, in the future the data will reside in a publicly accessible system. Note that report writers may choose to convert, adapt, or simplify the information they receive officially through our data base, thereby introducing data discrepancies between the data base and the public report. It is not always possible to incorporate and/or correct these errors when they occur. Issues in the audit will be discussed in the order in which they are presented in the audit report. Clarifications will also be noted as the audit report was a draft document, at the time of this response.

AUDITS↗