Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Distributed control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Transactive Control of Commercial Buildings for Demand Response

Transactive control is a type of distributed control strategy that uses market mechanism to engage self-interested responsive loads to achieve power balance in the electrical power grid. In this paper, we propose a transactive control approach of commercial building Heating, Ventilation, and Air- Conditioning (HVAC) systems for demand response. We first describe the system models, and identify their model parameters using data collected from Systems Engineering Building (SEB) located on our Pacific Northwest National Laboratory (PNNL) campus. We next present a transactive control market structure for commercial building HVAC system, and describe its agent bidding and market clearing strategies. Several case studies are performed in a simulation environment using Building Control Virtual Test Bed (BCVTB) and calibrated SEB EnergyPlus model. We show that the proposed transactive control approach is very effective at peak clipping, load shifting, and strategic conservation for commercial building HVAC systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrating System to Edge-of-Network Architecture and Management for SHINES (SEAMS) Technologies of High Penetration Grids

Consistent with the U.S. DOE’s EERE SHINES FOA objectives, the goal of this project was to enable integration from EMS to variable DER in a way that delivered visibility and opportunities for managing and controlling distributed resources using SEAMS technologies. This project implemented several SHINES technologies, which included: (1) three Stem battery systems; (2) six ConnectDER PV collars; (3) two E-Gear PV/Battery storage interfaces; and (4) eight Kitu smart inverter emulators. A Siemens Energy IP DEMS was deployed in a development environment and integrated with the SHINES technologies via OpenADR and IEEE 2030.5 protocols with documented architecture. In the case of IEEE 2030.5, a suite of technologies including a gateway, an API, software and a server from Kitu Systems (the Citadel, Convoy, Kitu Crosslink API, and Kitu Spark) were used to demonstrate that the utility could achieve visibility of distributed energy resources (DER) and control of single and multiple DER systems with a single command. The project also included a LCOE analysis of SHINES technologies compared to traditional system and circuit mitigation measures.

14 SOLAR ENERGY↗

Consensus-Based Approach for Active Power Control and Reserve Estimation in Distributed PV Systems

With the increased adoption of distributed energy resources (DER), they are expected to contribute to power system reliability services and enhance power system stability. This paper presents a distributed consensus control approach for the real-time active power reserve estimation and power management in distributed PV (photovoltaic) systems. The proposed method estimates the cumulative active power reserve from numerous PV generators using only the sparse communication network for a DER aggregator to provide active power regulation services. The real-time active power reserve estimation using the proposed approach can be used by DER aggregators to manage curtailment in distributed PV systems to maintain stipulated reserves and further to provide power system frequency regulation. Using the proposed approach, the DER aggregator only requires measurements at the feeder substation and it does not require information from individual DER units, thereby improving system resiliency. The proposed distributed consensus control method is validated on IEEE 123 testbed using PSCAD simulations.

active power reserve↗

Consensus-Based Approach for Active Power Control and Reserve Estimation in Distributed PV Systems: Preprint

With the increased adoption of distributed energy resources (DER), they are expected to contribute to power system reliability services and enhance power system stability. This paper presents a distributed consensus control approach for the real-time active power reserve estimation and power management in distributed PV (photovoltaic) systems. The proposed method estimates the cumulative active power reserve from numerous PV generators using only the sparse communication network for a DER aggregator to provide active power regulation services. The real-time active power reserve estimation using the proposed approach can be used by DER aggregators to manage curtailment in distributed PV systems to maintain stipulated reserves and further to provide power system frequency regulation. Using the proposed approach, the DER aggregator only requires measurements at the feeder substation and it does not require information from individual DER units, thereby improving system resiliency. The proposed distributed consensus control method is validated on IEEE 123 testbed using PSCAD simulations.

active power reserve↗

A Distributed Intelligent Automated Demand Response Building Management System

The goal of the 2.5 year Distributed Intelligent Automated Demand Response (DIADR) project was to reduce peak electricity load of Sutardja Dai Hall at UC Berkeley by 30% while maintaining a healthy, comfortable, and productive environment for the occupants. We sought to bring together both central and distributed control to provide “deep” demand response1 at the appliance level of the building as well as typical lighting and HVAC applications. This project brought together Siemens Corporate Research and Siemens Building Technology (the building has a Siemens Apogee Building Automation System (BAS)), Lawrence Berkeley National Laboratory (leveraging their Open Automated Demand Response (openADR), Auto-­Demand Response, and building modeling expertise), and UC Berkeley (related demand response research including distributed wireless control, and grid-­to-­building gateway development). Sutardja Dai Hall houses the Center for Information Technology Research in the Interest of Society (CITRIS), which fosters collaboration among industry and faculty and students of four UC campuses (Berkeley, Davis, Merced, and Santa Cruz). The 141,000 square foot building, occupied in 2009, includes typical office spaces and a nanofabrication laboratory. Heating is provided by a district heating system (steam from campus as a byproduct of the campus cogeneration plant); cooling is provided by one of two chillers: a more typical electric centrifugal compressor chiller designed for the cool months (Nov-­ March) and a steam absorption chiller for use in the warm months (April-­October). Lighting in the open office areas is provided by direct-­indirect luminaries with Building Management System-­based scheduling for open areas, and occupancy sensors for private office areas. For the purposes of this project, we focused on the office portion of the building. Annual energy consumption is approximately 8053 MWh; the office portion is estimated as 1924 MWh. The maximum peak load during the study period was 1175 kW. Several new tools facilitated this work, such as the Smart Energy Box, the distributed load controller or Energy Information Gateway, the web-­based DR controller (dubbed the Central Load-­Shed Coordinator or CLSC), and the Demand Response Capacity Assessment & Operation Assistance Tool (DRCAOT). In addition, an innovative data aggregator called sMAP (simple Measurement and Actuation Profile) allowed data from different sources collected in a compact form and facilitated detailed analysis of the building systems operation. A smart phone application (RAP or Rapid Audit Protocol) facilitated an inventory of the building’s plug loads. Carbon dioxide sensors located in conference rooms and classrooms allowed demand controlled ventilation. The extensive submetering and nimble access to this data provided great insight into the details of the building operation as well as quick diagnostics and analyses of tests. For example, students discovered a short-­cycling chiller, a stuck damper, and a leaking cooling coil in the first field tests. For our final field tests, we were able to see how each zone was affected by the DR strategies (e.g., the offices on the 7th floor grew very warm quickly) and fine-­tune the strategies accordingly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enabling Interoperable SCADA Communications for PV Inverters through Embedded Controllers

The percentage integration of photovoltaic (PV) inverters in the field has increased significantly in the past 5 years. Regardless of the size of the PV plants and the inverters (residential vs. commercial), it is becoming crucial that these devices have the capability to communicate with peers (other smart devices) and with components that are at a hierarchy above the inverters (e.g., supervisory control and data acquisition (SCADA) systems, distributed controllers, and data managers). This project aims to develop a standard SCADA software code for inverters’ embedded controllers that will enable interoperability with other components in the system. To achieve this, the code will be developed using two different protocols: Distributed Network Protocol 3 and International Electrotechnical Commission 61850. The developed code is aimed to be deployed in simple embedded controllers. It will be tested in the National Renewable Energy Laboratory’s (NREL’s) Energy Systems Integration Facility. The tested code will then be made available through Triangle MicroWorks’s (TMW’s) software platform. The primary objectives of this project include training the NREL team with TMW’s embedded controller libraries, developing an interoperable communication code for embedded controllers, successfully testing and deploying the code, and demonstrating the newly developed code in a conference.

14 SOLAR ENERGY↗

Feedforward Control of Fuel Distribution on Advanced Dual-Fuel Engines with Varying Intake Valve Closing Timings

This study examines the dynamics and control of an engine operated with late intake valve closure (LIVC) timings in a dual-fuel combustion mode. The engine features a fuel delivery system in which diesel is direct-injected and natural gas is port-injected. Despite the benefits of LIVC and dual-fuel strategy, combining these two techniques resulted in efficiency losses due to the variability of the combustion process across cylinders. The difference in power production across cylinders ranges from 9% at an IVC of 570°ATDC* to 38% at an IVC of 620 °ATDC and indicates an increasingly uneven fuel distribution as the intake valve remains open longer in the compression stroke. This paper describes an approach for controlling the amount of fuel injected into each cylinders’ port of an inline six- cylinder heavy-duty dual-fuel engine to minimize the variations in fuel distribution across cylinder. Since measuring the actual fuel reaching each cylinder is not a practical option on stock engines, this study aimed to produce a feedforward control technique. Using a model developed on an engine simulation software, the optimal fuel injection amounts at each cylinder port across 125 operating conditions (consisting of sweeps of five engine speeds, five engine loads, and five IVC timings) were determined by using PI controllers that adjust the amount of fuel injected at each port based on the amount of fuel reaching the cylinders. The results from the PI controller were expressed as a function of the operating condition (engine speed, engine load, and IVC timing); and consequently, could be reproduced without relying on a measurement of the amount of fuel reaching each cylinder. The feedforward control strategy, unlike the PI controller, is easily implementable on a stock engine and significantly reduces the variations in fuel distribution across cylinders.

Kassa, Mateos↗

Optimal Distribution System Voltage Regulation using State Estimation and DER Grid-Support Functions

Increasing solar energy penetrations may create challenges for distribution system operations because production variability can lead to large voltage deviations or protection system miscoordination. Instituting advanced management systems on distribution systems is one promising method for combating these challenges by intelligently controlling distribution assets to regulate voltage and ensure protection safety margins. While it is generally not the case today, greater deployment of power system sensors and interoperable distributed energy resources (DER)e.g., photovoltaic (PV) inverters, energy storage systems (ESS), electric vehicles (EVs)will enable situational awareness, control, and optimization of distribution systems. In this work, a control system was created which measures power system parameters to estimate the status of a feeder, forecasts the distribution state over a short-term horizon, and issues optimal set point commands to distribution-connected equipment to regulate voltage and protect the system. This two-year project integrated multiple research innovations into a management system designed to safely allow PV penetrations of 50% or greater. The integrated software was demonstrated through extensive real-time (RT) and power hardware-in-the-loop studies and a field demonstration on a live power system with a 684 kVA PV system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

State-Constrained Grid-Forming Inverter Control for Robust Operation of AC Microgrids

The control of grid-forming inverters has become an important problem to achieve high efficiency, reliability, and resilience of the future power grid. The distributed control that utilizes a sparse communication network has been proposed for AC microgrids, in which each DG only has access to the information of a small number of its neighboring DGs, reducing the computational complexity and improving the resiliency to faults and unknown parameters. However, these approaches have not provided a clear analysis of the coupling between active/reactive power injections and the voltage magnitude/frequency or a distributed updating law with a solid theoretical foundation. Additionally, in the existing approaches, tracking the references from the secondary control may violate operational constraints.

Xu, Ying↗

Quantum Reinforcement Learning for Volt-VAR Control in Power Distribution Systems

Volt-VAR control (VVC) is crucial in active distribution networks for optimizing voltage profiles and minimizing network losses. While traditional deep reinforcement learning (DRL) algorithms exhibit promise for VVC, they often require extensive computational resources to handle such a high-dimensional problem. As a potential solution, quantum reinforcement learning (QRL) algorithms integrate the computational capabilities of quantum computing into the DRL framework. However, existing QRL algorithms struggle with complex VVC problems due to the limitations of current quantum hardware. To bridge this gap, this paper proposes an innovative QRL algorithm featuring an end-to-end architecture that integrates a classical autoencoder, variational quantum circuits (VQCs), and classical post-processing layers. This design efficiently compresses high-dimensional grid states, enabling VQCs to leverage quantum advantages while producing multiple control device outputs tailored for VVC tasks. Numerical studies on three representative distribution systems verify the effectiveness and scalability of the proposed QRL algorithm, and demonstrate its enhanced performance over classical approaches with only approximately 1% of the parameters. Additionally, the robustness of our developed algorithm is validated through noisy quantum environments.

97 MATHEMATICS AND COMPUTING↗

Decimeter-scale mapping of carbonate-controlled trace element distribution in Neoarchean cuspate stromatolites

We present that ancient stromatolites can provide key insights into the early evolution of life on Earth. Neoarchean fenestrate stromatolites from the ~2520 Ma Upper Nauga Formation (Transvaal Supergroup, South Africa) preserve cuspate morphologies. They possess clearly delineated support and drape structures interpreted as dolomitized microbial mat material. Petrographic observations show that the biogenic structures are composed of planar-s to non-planar ferroan dolomite, encased in ferroan calcite, including herringbone calcite textures. The cuspate stromatolites were analyzed using Synchrotron Rapid Scanning X-Ray Fluorescence (SRS-XRF) and more conventional techniques to determine: (i) whether element distributions could be distinguished in ancient stromatolites at both cm to dm scales, (ii) whether element distributions show variation between biogenic and abiogenic textures, and (iii) the sample’s paragenesis. The distributions of Ca, Fe, Mn, Pb, Cu, As, Br, Al, Si, P, and S directly correspond to dolomitized stromatolitic structures and show trace element distributions are principally controlled by calcite and dolomite occurrence. Dolomite formation was mainly driven by seawater-derived fluids given the high concentrations of Fe and retention of marine shale-normalized rare earth element and yttrium (REY SN ) patterns, however the spatial association of dolomite to stromatolite structures may reflect microbially-influenced mineral nucleation. Lastly, given the complexity of this sample’s paragenetic evolution, trace metal distributions cannot be conclusively tied to specific metabolic pathways, bioaccumulation or passive binding, however, the results show SRS-XRF can be used for quantifiable, spatial, in-situ investigation of ancient microbialites.

58 GEOSCIENCES↗

Predictive and Cooperative Voltage Control with Probabilistic Load and Solar Generation Forecasting

This paper proposes predictive cooperative voltage control method in a power system with high penetration of photovoltaic (PV) units. Cooperative distributed control of the reactive power output of PV inverters is coordinated with operation of voltage regulators (VRs) to maintain system voltages within an appropriate bandwidth. Probabilistic forecasting of the solar power generation and the loads is applied to estimate voltage changes which, in turn, are used to set the VR tap positions for preventing large voltage fluctuations with the lowest risk considering the voltage distribution estimation. The fine tuning of voltage adjustment is achieved by cooperative control of PV inverters to maintain a uniform voltage profile across the system. The proposed method is tested on the modified IEEE 123-node test feeder with high PV penetration using real insolation data and with constant loads replaced by several different load profiles. Simulation results demonstrate the effectiveness of the coordinated approach for voltage control with cooperative PV and predictive VR controls taking into account probabilistic load and solar power forecasts.

Cooperative Control↗

Online Stochastic Optimization of Networked Distributed Energy Resources

Our work investigates distributed control and incentive mechanisms to coordinate distributed energy resources (DERs) with both continuous and discrete decision variables as well as device dynamics in distribution grids. We formulate a multi-period social welfare maximization problem, and based on its convex relaxation propose a distributed stochastic dual gradient algorithm for managing DERs. Moreover, we extend it to an online realtime setting with time-varying operating conditions, asynchronous updates by devices, and feedback being leveraged to account for nonlinear power flows as well as reduce communication overhead. The resulting algorithm provides a general online stochastic optimization algorithm for coordinating networked DERs with discrete power setpoints and dynamics to meet operational and economic objectives and constraints. We characterize the convergence of the algorithm analytically and evaluate its performance numerically.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparing Cetane Number Measurement Methods

Cetane number is one of the most important fuel performance metrics for mixing controlled compression-ignition “diesel” engines, quantifying a fuel’s propensity for autoignition when injected into end-of-compression-type temperature and pressure conditions. The historical default and referee method on a Cooperative Fuel Research (CFR) engine configured with indirect fuel injection and variable compression ratio is cetane number (CN) rating. A subject fuel is evaluated against primary reference fuel blends, with heptamethylnonane defining a low-reactivity endpoint of CN = 15 and hexadecane defining a high-reactivity endpoint of CN = 100. While the CN scale covers the range from zero (0) to 100, typical testing is in the range of 30 to 65 CN. Alternatively, several constant-volume combustion chamber (CVCC)-based cetane rating devices have been developed to rate fuels with an equivalent derived cetane number (DCN) or indicated cetane number (ICN). These devices measure ignition delay for fuel injected into a fixed volume of high-temperature and high-pressure air to simulate end-of-compression-type conditions. In this study, a range of novel fuel compounds are evaluated across three CVCC methods: the Ignition Quality Tester (IQT), Fuel Ignition Tester (FIT), and Advanced Fuel Ignition Delay Analyzer (AFIDA). Resulting DCNs and ICNs are compared for fuels within the normal diesel fuel range of reactivity, as well as very high (~100) and very low DCNs/ICNs (~5). Distinct differences between results from various devices are discussed. This is important to consider because some new, high-efficiency advanced compression-ignition (CI) engine combustion strategies operate with more kinetically controlled distributed combustion as opposed to mixing controlled diffusion flames. These advanced combustion strategies may benefit from new fuel chemistries, but current rating methods of CN, DCN, and ICN may not fully describe their performance. In addition, recent evidence suggests ignition delay in modern on-road diesel engines with high-pressure common rail fuel injection systems may no longer directly correlate to traditional CN fuel ratings. Simulated end-of-compression conditions are compared for CN, DCN, and ICN and discussed in the context of modern diesel engines to provide additional insight. Results highlight the potential need for revised and/or multiple fuel test conditions to measure fuel performance for advanced CI strategies.

47 OTHER INSTRUMENTATION↗

Distillation Column Flooding Predictor

The Flooding Predictor™ is a patented advanced control technology proven in research at the Separations Research Program, University of Texas at Austin, to increase distillation column throughput by over 6%, while also increasing energy efficiency by 10%. The research was conducted under a U. S. Department of Energy Cooperative Agreement awarded to George Dzyacky of 2ndpoint, LLC. The Flooding Predictor™ works by detecting the incipient flood point and controlling the column closer to its actual hydraulic limit than historical practices have allowed. Further, the technology uses existing column instrumentation, meaning no additional refining infrastructure is required. Refiners often push distillation columns to maximize throughput, improve separation, or simply to achieve day-to-day optimization. Attempting to achieve such operating objectives is a tricky undertaking that can result in flooding. Operators and advanced control strategies alike rely on the conventional use of delta-pressure instrumentation to approximate the column’s approach to flood. But column delta-pressure is more an inference of the column’s approach to flood than it is an actual measurement of it. As a consequence, delta pressure limits are established conservatively in order to operate in a regime where the column is never expected to flood. As a result, there is much “left on the table” when operating in such a regime, i.e. the capacity difference between controlling the column to an upper delta-pressure limit and controlling it to the actual hydraulic limit. The Flooding Predictor™, an innovative pattern recognition technology, controls columns at their actual hydraulic limit, which research shows leads to a throughput increase of over 6%. Controlling closer to the hydraulic limit also permits operation in a sweet spot of increased energy-efficiency. In this region of increased column loading, the Flooding Predictor is able to exploit the benefits of higher liquid/vapor traffic that produce increased contact area and lead to substantial increases in separation efficiency – which translates to a 10% increase in energy efficiency on a BTU/bbl basis. The Flooding Predictor™ operates on the principle that between five to sixty minutes in advance of a flooding event, certain column variables experience an oscillation, a pre-flood pattern. The pattern recognition system of the Flooding Predictor™ utilizes the mathematical first derivative of certain column variables to identify the column’s pre-flood pattern(s). This pattern is a very brief, highly repeatable, simultaneous movement among the derivative values of certain column variables. While all column variables experience negligible random noise generated from the natural frequency of the process, subtle pre-flood patterns are revealed among sub-sets of the derivative values of column variables as the column approaches its hydraulic limit. The sub-set of column variables that comprise the pre-flood pattern is identified empirically through in a two-step process. First, 2ndpoint’s proprietary off-line analysis tool is used to mine historical data for pre-flood patterns. Second, the column is flood-tested to fine-tune the pattern recognition for commissioning. Then the Flooding Predictor™ is implemented as closed-loop advanced control strategy on the plant’s distributed control system (DCS), thus automating control of the column at its hydraulic limit.

02 PETROLEUM↗

Smarter Grid Solutions | National Renewable Energy Laboratory: Active Management Integration: June 2015 - November 2016

This report presents the project results for the NREL INTEGRATE demonstration project: Active Network Management (ANM) Integration. Consistent with the INTEGRATE program's objective of increasing the grid's clean energy hosting capacity and providing grid services in a holistic manner, the project demonstrated the use of ANM to enable very high penetrations of solar PV and wind energy systems. Results obtained using a representative North American distribution system showed ANM's autonomous distributed control doubled the interconnected wind and solar systems by managing thermal and voltage constraints in real-time. These generators flexibly interconnected to the grid via ANM's end-to-end control architecture, and were managed and coordinated with other smart distributed energy resources (DER; e.g. EVs, battery ESS, controllable load) to unlock the grid's dynamic hosting capacity. As a smart grid application to standardize grid integration of diverse renewable generation sources, ANM provides the industry with a scalable, cost-effective alternative to traditional transmission and distribution (T&D) reinforcements. This project considered three use cases of the application of ANM: a Smart Home demonstration of ANM control of residential scale devices (PV, EV, and battery ESS); a Smart Campus demonstration of high penetration megawatt-scale DER (PV, EVs, battery ESS, and controllable load) behind a single point-of-common-coupling (PCC), and a Smart Distribution demonstration that combined prior use cases along with additional community/utility-scale DER at very high aggregate penetration levels. The Smart Distribution use case provided an integrated perspective of ANM across all distribution grid DER device scales (incorporating aggregated Smart Homes and the Smart Campus) in order to showcase how these devices can support smart grid services to manage DER related constraints in a safe and reliable manner; and likewise how ANM integrates with grid modernization initiatives. The ANM system was deployed in NREL's Energy Systems Integration Facility (ESIF), and project industry advisors attended an on-site demonstration and a set of workshops in order to review project outcomes and evaluate the relevance of ANM for increasing the grid hosting capacity. The outcomes of this effort include an assessment of opportunities for field deployment of ANM to address existing interconnection challenges, as well as consolidating project advisor suggestions for investment in ANM and potential future pilots for more advanced schemes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hierarchical Model-Free Transactive Control of Building Loads to Support Grid Services

Residential buildings consume 4.4 quads of electricity annually, approximately 37% of the total electricity consumption in the United States. This represents a vast resource that can be used for demand management and other ancillary services. This project aims to develop a robust, scalable hierarchical transactional control mechanism incorporating elements of model-free control (MFC) and game theory to harness buildings to provide ancillary services to the grid. This approach is being taken to address the challenges of incorporating traditional transactional control schemes into existing buildings. The challenges include small individual building sizes requiring aggregation of many buildings, unpredictable energy usage that makes model identification difficult, and satisfying the sensitive occupant comfort constraints. In the proposed approach, by separating the control mechanism into two layers above and below the load aggregator, MFC can be used below the aggregator to modulate flexible building loads in response to pricing signals with guaranteed performance. This allows the burden of identifying an accurate model of the system to be shifted to the above-aggregator layer, where fluctuations in individual building usage have less impact on predicted building system behavior. Game theory concepts can then be used to determine pricing curves and control signals among regional aggregators. Managing this control in a game-theoretic approach will allow us to build in financial incentives that increase customer engagement. Additionally, the usage of MFC necessitates less burdensome computational and communication requirements, thus, it is easily deployable on small, embedded devices. In a broader sense, developing a strategy capable of effectively incorporating residential and small commercial buildings will allow greater throughput of existing and emerging grid services in addition to future transactive energy grid management methods. Using MFC within a hierarchical control architecture will allow the shifting of existing forecasting challenges to an aggregate level, where dynamics are slower and more predictable. This will enable a smooth interface between the grid services requests of utilities and the reliable control required by participating buildings. MFC, which supports distributed control architecture, permits a scalable solution that can be deployed to neighborhood-size systems as well as individual buildings. This project focuses on three objectives: (1) developing the mathematical framework, algorithm toolkit, and software toolset of the two-layer transactive control testbed; (2) developing a scalable solution for application over many residential and small-size commercial buildings with sparse distributed communication; and (3) field testing and implementation on hardware of the control strategies developed in the previous two objectives. The research and development activities are focused and designed to be impactful within the relevant 2025 targets timeframe. An open-source control framework for exploiting variability and dispatchability of building loads will be delivered as the outcome of the project. This capability enables greater participation of loads in electricity markets and ancillary services that are both useful for the utility and financially beneficial for building owners.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

3D model generation using an airborne swarm

Using an artificial kinematic field to provide co-ordination between multiple inspection UAVs, the authors herein demonstrate full 3D modelling capability based on a photogrammetric system. The operation of the system is demonstrated by generating a full 3D surface model of an intermediate level nuclear waste storage drum. Such drums require periodic inspection to ensure that drum distortion or corrosion is carefully monitored. Performing this inspection with multiple airborne platforms enables rapid inspection of structures that are inaccessible to on-surface remote vehicles and are in human-hazardous environments. A three-dimensional surface-meshed model of the target can then be constructed in post-processing through photogrammetry analysis of the visual inspection data. The inspection environment uses a tracking system to precisely monitor the position of each aerial vehicle within the enclosure. The vehicles used are commercially available Parrot AR. Drone quadcopters, controlled through a computer interface connected over an IEEE 802.11n (WiFi) network, implementing a distributed controller for each vehicle. This enables the autonomous and distributed elements of the control scheme to be retained, while alleviating the vehicles of the control algorithm’s computational load. The control scheme relies on a kinematic field defined with the target at its centre. This field defines the trajectory for all the drones in the volume relative to the central target, enabling the drones to circle the target at a set radius while avoiding drone collisions. This function enables complete coverage along the height of the object, which is assured by transitioning to another inspection band only after completing circumferential coverage. Using a swarm of vehicles, the time until complete coverage can be significantly reduced.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗