Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Demagnetization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

MAGNETIC HYGIENE CONTROL ON LCLS-II CRYOMODULES FABRICATED AT JLAB

Jefferson Lab (JLab) is in collaboration with Fermi Na-tional Accelerator Laboratory (Fermilab) to build 18 cryomodules to install at the SLAC National Accelerator Laboratory?s tunnel as part of the Linac Coherent Light Source upgrade project (LCLS-II). Each LCLS-II cry-omodule hosts 8 superconducting niobium cavities that adopt the nitrogen doping technique, which aims to en-hance the cavity quality factor Qo to reduce the consumption of liquid helium used to cool down the cavities. It is known that the Qo of niobium cavities is affected by cavity surface magnetic field. Traditionally, magnetic shields made of high magnetic permeability mu-metals are employed as a passive shielding of the ambient magnetic fluxes. During the LCLS-II cryomodule development, magnetic hygiene control that includes magnetic shielding and demagnetization of parts and the whole-machine is implemented. JLab and Fermilab worked closely on developing magnetic hygiene control procedures, identifying relevant tools, investigating causes of magnetization, magnetic field monitoring, etc. This paper focuses on JLab?s experiences with LCLS-II cryomodule magnetic hygiene control during its fabrication.

Cheng, Guangfeng↗

Unique Lanthanide-Free Motor Construction

This project pursued the development of a non-rare-earth permanent magnet motor architecture. It incorporated a novel rotor geometry that allowed the use of lower energy Al-Ni-Co high flux, low coercivity magnet material. This material was not readily adopted at the start of the project, due to demagnetization within existing magnetic circuit designs, a problem that was overcome with the final design produced in the project. The result of the research and testing showed that it is feasible to produce an AlNiCo motor, meeting the DOE performance targets, while exceeding DOE 2015 cost targets and nearly meeting 2020 cost targets.

33 ADVANCED PROPULSION SYSTEMS↗

Design and Manufacture of Tunable Permanent Magnet Based Quadrupole for Next Generation Electron-Ion Colliders [Slides]

The goal of this project is to design and construct of a prototype of quadrupole permanent magnet for the magnet transport lattice for an electron-ion collider. The technical objectives are not only to achieve the field gradient of 34.42T/m in the region of interest, at a radius 16.0mm, relative to the quadrupole axis (z-axis), but also lower the unwanted field harmonics below one unit out of 10,000, especially for Sextupole, Octupole, and Decapole components. The innovation is 1) modular design for cost saving, and 2) adjusting mechanism of each modular magnet for field tuning. The 300-mm long, quadrupole magnet assembly consists of 12 modules of 100-mm long magnet. The magnetic field tuning was implemented by two ways: first, adjusting mechanically the pole tip position for a majority of field tuning, and second, applying the passive shims for a fine field tuning. The magnetic design and optimization of the quadrupole magnet was performed using finite element analysis. The permanent magnet choice was EEC-N44SH grade with the minimum coercivity of 987kA/m (12.4kOe), which has enhanced resistance to demagnetization due to the radiation. The 3D computer-aided design of quadrupole magnet assembly was created based on the magnetic design results. The overall dimensions are 514x500x300mm and its weight is ~470kg (1,050lbs). The weight and volume were minimized through the optimization. Electron Energy Corporation’s vertically integrated manufacturing capability and over 48-years magnet production experience enabled us to implement a “fast prototyping” process and build two quadrupole magnets. Using wire EDM machines, the pole tip profile was precisely fabricated within ±25µm tolerance. The field gradient 34.22T/m was measured using the real time data acquisition system and a 3D Hall probe mounted on the precision XYZ station with the resolution of 1µm (0.00004”). The magnetic field harmonics were measured using a harmonic coil at the Brookhaven National Laboratory, Upton, NY. Faro® laser tracker was used to track the position of each quadrupole while adjusting the pole location mechanically. The normal harmonics were measured up to 20-poles. Overall the 2 nd magnet test data is better than the 1st magnet because of a better symmetry. The adjusting pole technique was proved effective to lower the Sextupole harmonics from -3.14 to -0.71 unit. The Octupole harmonics was improved from -5.67 to -3.45 unit, still not satisfactory. It is found that the proposed approach is not practical and efficient in terms of the mass production although the modular concept can save the manufacturing cost. Another finding is in reality it is hard to adjust mechanically due to the limit of laser tracker resolution .001” and tweak magnetically the field due to the limited harmonics data. Importantly the Brookhaven National Laboratory’s harmonics data doesn’t indicate where the strong/weak field position, which requires another field map test at each measurement. To resolve these, two alternative solutions are introduced; 1) electromagnet correcting coils and 2) 8-pieces quadrupole magnet.

43 PARTICLE ACCELERATORS↗

Repair and Retuning of 3-m long In-Vacuum Undulator at NSLS-II

A 3.0 m long In-Vacuum Undulator (IVU) is employed at the National Synchrotron Light Source II (NSLS-II) for the Hard X-ray Nanoprobe (HXN) beamline providing structural and X-ray fluorescence imaging with world-leading spatial resolution. On July 1st 2018 a gearbox shaft in the gap drive train assembly sheared due to corrosion fatigue caused by stress due to mechanical misalignment. The device was extracted from the storage ring and measured. The magnetic field measurements detected a degradation of the magnetic performance as well as a localized demagnetization of the magnetic modules of the first 3 upstream periods. This paper describes the mechanical repairs and the magnetic phase shimming optimization implemented to restore the spectral performance of the device.

36 MATERIALS SCIENCE↗

The application of macroscopic flakes for Fe-6.5%Si bulk magnetics with superior magnetic properties

Inductors are used in power electronics to convert current to different frequency and voltage. They are used extensively from where power is generated all the way to electric vehicles and portable electronic devices. The soft magnetic materials used in the inductors is critical for the performance of the inductors. Currently, a majority of the inductor uses powder core. The use of powder is not ideal as the 3D granule powders generate large demagnetization field working against the applied field, resulting in reduced permeability and efficiency. In this paper, 2D flakes were used to replace the 3D granules as the feedstock for fabricating inductor core. The crystalline Fe-Si based crystalline soft magnetic material in the form of flakes approximately 0.1mm thick, 1mm long and 2mm wide were prepared via melt spinning. The flakes were then coated with insulating materials before compacted into a toroid. The effect of coating thickness and concentration on magnetic properties of the toroidal sample are studied. It was also found that the magnetic cores made by flakes surpass the cores made by same size powder with larger permeability and lower iron losses.

Fe-6.5%Si Steel↗

Magnetic Avalanche Detector using Single-Molecule Magnets

Here we discuss the results of the 9 month add-on project: “Magnetic Avalanche Detector using Single-Molecule Magnets”. The key point of the projects was to design a cryogenic system that is capable of applying magnetic fields high enough to magnetize the Single-Molecule Magnets (SMMs), maintain temperatures below 1K, and be able to detect magnetic avalanches of the SMM domains. We were able to achieve these goals. Our system was able to magnetize and sense the magnetization of SMM crystals. Moreover, we were able to detect avalanche demagnetization events caused by an alpha particle interacting with a magnetized SMM.

47 OTHER INSTRUMENTATION↗

Cryogenic Performance of the SPT-SLIM Receiver

The South Pole Telescope Shirokoff Line Intensity Mapper (SPT-SLIM) is a millimeter-wave line-intensity mapping experiment, deployed on the South Pole Telescope (SPT) during the 2024-2025 Austral Summer season. This pathfinder experiment serves to demonstrate the on-sky operation of multi-pixel on-chip spectrometer technology. We present on the cryogenic performance of the SPT-SLIM receiver for this Year 1 observing campaign. The SPT-SLIM receiver utilizes an Adiabatic Demagnetization Referigerator (ADR) for cooling the focal plane of superconducting filterbank spectrometers to a temperature of 150mK. We demonstrate stable thermal performance of the focal plane module during observing operations in line with thermal modelling, enabling a cryogenic operation efficiency above 80%. We also report on the receiver control system design utilizing the Observatory Control System (OCS) platform for automated cryogenic operation on the SPT.

Young, Matthew [Fermilab]↗

AL-CRADA-2025-01 Final Report: American-Made Wind Turbine Materials Recycling Prize Accelerate! Phase 2

This report summarizes the Phase 2 achievements of the Wind Turbine Materials Recycling Prize project led by Critical Materials Recycling (CMR) in partnership with Ames National Laboratory. The team demonstrated the technical feasibility and economic viability of recovering and reusing rare-earth Nd-Fe-B magnets from end-of-life (EOL) wind turbine generators. Through mechanical disassembly, demagnetization, and precision processing, magnets were harvested and characterized to assess structural, compositional, and magnetic properties. Results showed that recovered magnets performed on par with commercial-grade counterparts, enabling their integration into actuator and motor prototypes without redesign. System-level modeling and finite-element simulations validated operational performance, while Life Cycle Cost (LCC) analysis revealed up to 20% material cost savings and 2–3% reductions in overall motor system costs. Life Cycle Assessment (LCA) further confirmed substantial environmental benefits, including a ~94% reduction in global warming potential relative to virgin magnet production. The project’s success was enabled by a tightly integrated partnership between industry and national lab experts, illustrating a viable path for domestic magnet-to-magnet recycling. These findings support a scalable, circular solution for rare-earth material recovery, reducing dependence on imported critical minerals and advancing sustainable clean energy technologies.

Lograsso, Thomas [Ames Laboratory (AMES), Ames, IA↗

Investigating the Performance of a Fully Laminated Flux-Focusing Magnetic Gearbox

This paper presents here the design investigation and experimental testing of a flux-focusing magnetic gearbox with a fully laminated rotor structure. The unique feature of this flux-focusing magnetic gearbox design is that the three rotors are each made of a single lamination stack, and the central modulation structure is retained in place without the use of a resin filler such as epoxy. Ferromagnetic bridges are used to connect individual pole pieces together. It is shown that the use of the ferromagnetic bridges reduces the calculated torque density from 156 Nm/L to 139 Nm/L (a reduction of 11%). The experimentally measured torque density is, however, only 97 Nm/L. The reason for this discrepancy is associated with the demagnetization of the magnets.

42 ENGINEERING↗

Efficient Optical Control of Magnon Dynamics in van der Waals Ferromagnets

Optical control of magnons in two-dimensional (2D) materials promises new functionalities for spintronics and magnonics in atomically thin devices. Here, we report control of magnon dynamics, using laser polarization, in a ferromagnetic van der Waals (vdW) material, Fe 3.6 Co 1.4 GeTe 2 . The magnon amplitude, frequency, and lifetime are controlled and monitored by time-resolved pump-probe spectroscopy. We show substantial (over 25%) and continuous modulation of magnon dynamics as a function of incident laser polarization. Our results suggest that the modification of the effective demagnetization field and magnetic anisotropy by the pump laser pulses with different polarizations is due to anisotropic optical absorption. This implies that pump laser pulses modify the local spin environment, which enables the launch of magnons with tunable dynamics. Our first-principles calculations confirm the anisotropic optical absorption of different crystal orientations. Our findings suggest a new route for the development of opto-spintronic or opto-magnonic devices.

36 MATERIALS SCIENCE↗

EVIDENCE FOR QUASI-ADIABATIC MOTION OF CHARGED PARTICLES IN STRONG CURRENT SHEETS IN THE SOLAR WIND

We investigate quasi-adiabatic dynamics of charged particles in strong current sheets (SCSs) in the solar wind, including the heliospheric current sheet (HCS), both theoretically and observationally. A self-consistent hybrid model of an SCS is developed in which ion dynamics is described at the quasi-adiabatic approximation, while the electrons are assumed to be magnetized, and their motion is described in the guiding center approximation. The model shows that the SCS profile is determined by the relative contribution of two currents: (i) the current supported by demagnetized protons that move along open quasi-adiabatic orbits, and (ii) the electron drift current. The simplest modeled SCS is found to be a multi-layered structure that consists of a thin current sheet embedded into a much thicker analog of a plasma sheet. This result is in good agreement with observations of SCSs at ∼1 au. The analysis of fine structure of different SCSs, including the HCS, shows that an SCS represents a narrow current layer (with a thickness of ∼10{sup 4} km) embedded into a wider region of about 10{sup 5} km, independently of the SCS origin. Therefore, multi-scale structuring is very likely an intrinsic feature of SCSs in the solar wind.

79 ASTRONOMY AND ASTROPHYSICS↗

Paleomagnetic and rock-magnetic studies of the Permian Cutler and Elephant Canyon formations in Utah.

Study of the Permian Cutler formation and the upper 15 meters of the Permian Elephant Canyon formation at 0.6-meter stratigraphic intervals southwest of Moab in eastern Utah. The directions of natural remanent magnetization show a pronounced streak distribution, but thermal demagnetization successfully isolates the stable paleomagnetic direction. All directions are reversed, and no significant long-term change in pole position is observed throughout the entire section. The pole calculated from the Elephant Canyon data lies at 43.6 N, 119.6 E; the Cutler pole lies at 44.4 N, 116.2 E. Rock-magnetic analyses suggest that the secondary magnetization results from the iron hydroxides and was acquired after recent surface exposure.

Gose, W. A.↗

Magnetocaloric pump

Very cold liquids and gases such as helium, neon, and nitrogen can be pumped by using magnetocaloric effect. Adiabatic magnetization and demagnetization are used to alternately heat and cool slug of pumped fluid contained in closed chamber.

Brown, G. V.↗

Cause of secondary magnetization in lunar samples, part C

The unstable component of the magnetization found in lunar samples was investigated by returning a demagnetized tracer igneous rock sample from Apollo 12 to the moon on Apollo 16. After the return of the sample, the soft component was similar to the original soft component of the first trip. It is concluded that the soft component is an artifact of the trip.

Pearce, G. W.↗

Remanent magnetization of the lunar surface.

Two lines of evidence support each other in suggesting that a large volume of the rocks near the lunar surface possess a uniform remanent magnetization with an intensity of about .000002 emu/g. The first line is the discovery by several groups of investigators of weak but stable remanent magnetizations in igneous samples returned from the first four Apollo missions. Although the mechanism of acquisition of this remanence has not been definitely established, several lines of evidence, including thermal demagnetization, suggest that it is a thermoremanent magnetization (TRM) carried by iron. Many of the breccias are similarly magnetized. The second line is the measurement of significant fields at the Apollo sites and the discovery of large-scale anomalies by the sub-satellite magnetometer experiment.

Pearce, G. W.↗