SEARCH · Engineering Papers
Results for “Data acquisition systems”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Implementation of a High-Speed Multichannel Data Acquisition System for Magnetic Diagnostics and Plasma Centroid Position Control in ISTTOK
In tokamak and other fusion devices, magnetic control is the main tool that allows to regulate the plasma current, position and shape; it is in charge of actuating the desired plasma current waveform, steering the plasma position to a given set point and maintain the plasma shape close to a prescribed plasma equilibrium. This work describes the application of several physics concepts and computational tools in order to obtain a novel optimal controller for the plasma centroid position, which has been implemented and tested in the real-time plasma control system at the ISTTOK tokamak. A key point for the development of the new control system was the installation of a recently upgraded hardware, that numerically integrates in real-time the magnetic probes signals.
The Data Acquisition System of the KOTO Experiment and the RCE Platform Technology Upgrade
Not provided.
High speed, multi-channel, user programmable digital data acquisition system.
As applications for radiation detection become more demanding, and in turn improvements are made in the technology of radiation detection, there is a need for high speed digital detector readout electronics matching these improvements. Specifically, full control over the on-line processing resources of modern digital electronics is desirable so that researchers can develop custom algorithms for special applications.In the proposed effort, the 500 MHz digital readout electronics previously developed by our company will be redesigned to allow user access to the on-line processing resources. In Phase I, the division of online processing into vendor and user firmware sections has been studied on existing hardware. In Phase II, the hardware will be upgraded to better facilitate the division, and the firmware will be restructured into a robust vendor logic block (providing standard functions such as host I/O, on-board memory I/O, energy computation, MCA spectra, timestamps, waveform capture, run statistics, and triggering and timing) and a user logic block for custom algorithms (with templates and examples for frequently used functions). Investigating several options to divide online processing, it was determined that the most promising approach is to “partition” a single FPGA integrated circuit into a vendor and user section, which is supported in newer devices. The analog front end of the existing electronics proved suitable for most applications, in particular high rate measurements with germanium detectors. The design architecture for new electronics was developed, combining one of the new FPGA device with the analog front end.
Improving the Event Data Server of the Fermilab Test Beam Data Acquisition System (OTSDAQ)
The Fermilab Test Beam Facility (FTBF) is a high-energy test beam used for precision tests of high-energy physics detectors. The FTBF has two beams lines, MTest and MCenter, which provides a variety particle types such as proton beam and secondary beams with muons, electrons, and kaons. The beam is variable in energy and intensity, and a target can be inserted into the beam to convert the protons to other particle types for users.
A lightweight low-cost data acquisition system for device testing.
Abstract not provided.
Real-time performance of commercial Intel-based VME Controllers for the CODA data acquisition system
Explore the source record for details and available documents.
Mini-DAQ: A lightweight, low-cost, high resolution, data acquisition system for wave energy converter testing.
Abstract not provided.
Commissioning of the Mu2e Data AcQuisition System and the Vertical Slice Test of the Straw Tracker
Explore the source record for details and available documents.
Commissioning of the Mu2e Data AcQuisition System and the Vertical Slice Test of the Straw Tracker
The report discusses the commissioning of the DAQ system of the Mu2e experiment. We studied how the tracker works and especially the tracker readout. We used a generator to send pulses and we tried to understand the output and non-output of the DTC, in order to validate the event and run format and all the failure modes. In section one, we describe Charged Lepton Flavour Violation, the main purpose of Mu2e, in section two we describe Mu2e experiment. Section three presents the tracker description and readout, meanwhile section four the DAQ system and event building. In section five, we start explaining the analysis we have done on events and all the failure modes we discovered. In section six, we have done an analysis of the logger and boardreader rate, we validated the generator frequency in section seven and studied the number of hits in function of the channel number in section eight. To conclude we investigated the channel to channel time differences in section nine and in section ten we explain our Monte Carlo simulation, reproducing ROCs readout.
Software and Hardware Development for the Mu2e Trigger and Data Acquisition System
Italian Summer Students Final reports
Software and Hardware Development for the Mu2e Trigger and Data Acquisition System
The Mu2e experiment at Fermilab will be 10,000 times more sensitive than previous experiments looking for muon-to-electron conversion. This precise and complex experimental apparatus will produce 200 million billion muons per year. The accelerator complex repurposes elements of the infrastructure that produced high energy proton and anti-protons beams for the Tevatron experiments to produce the high-intensity muon beams necessary for Mu2e and the Muon (g-2) experiments.
Multiple-Input Data Acquisition System (MIDAS) for Measuring the Carbon Content in Soil Using Inelastic Neutron Scattering
Explore the source record for details and available documents.
Training manual ACE-S/C data acquisition system /PCM decommutator/, revision 4
Explore the source record for details and available documents.
Precision calibration and reference voltage source for data acquisition systems
Hybrid integrated circuit operational amplifiers, which have inherent characteristics of low quiescent power dissipation and extended operational lifetime with high reliability, are source for digital systems. Amplifiers are coupled to Zener reference diode in current control and buffer configuration.
A digital matched filter technique for the tracking and data acquisition system
Design information and test results for a breadboard implementation of a digital matched filter for PN sequences are reported. The device is intended to expedite acquisition in PN spread-spectrum communication systems.
A long-range and long-life telemetry data-acquisition system for heart rate and multiple body temperatures from free-ranging animals
The system includes an implantable transmitter, external receiver-retransmitter collar, and a microprocessor-controlled demodulator. The size of the implant is suitable for animals with body weights of a few kilograms or more; further size reduction of the implant is possible. The ECG is sensed by electrodes designed for internal telemetry and to reduce movement artifacts. The R-wave characteristics are then specifically selected to trigger a short radio frequency pulse. Temperatures are sensed at desired locations by thermistors and then, based on a heartbeat counter, transmitted intermittently via pulse interval modulation. This modulation scheme includes first and last calibration intervals for a reference by ratios with the temperature intervals to achieve good accuracy even over long periods. Pulse duration and pulse sequencing are used to discriminate between heart rate and temperature pulses as well as RF interference.
Recycling isoelectric focusing with computer controlled data acquisition system
Isoelectric focusing is a high-resolution technique for separating and purifying large peptides, proteins, and other biomolecules. The apparatus described in the present paper constitutes a new approach to fluid stabilization and increased throughput. Stabilization is achieved by flowing the process fluid uniformly through an array of closely spaced filter elements oriented parallel both to the electrodes and the direction of the flow. This seems to overcome the major difficulties of parabolic flow and electroosmosis at the walls, while limiting the convection to chamber compartments defined by adjacent spacers. Increased throughput is achieved by recirculating the process fluid through external heat exchange reservoirs, where the Joule heat is dissipated.