Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DEPTH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Observed damage during Argon gas cluster depth profiles of compound semiconductors

Argon Gas Cluster Ion Beam (GCIB) sources have become very popular in XPS and SIMS in recent years, due to the minimal chemical damage they introduce in the depth-profiling of polymer and other organic materials. These GCIB sources are therefore particularly useful for depth-profiling polymer and organic materials, but also (though more slowly) the surfaces of inorganic materials such as semiconductors, due to the lower roughness expected in cluster ion sputtering compared to that introduced by monatomic ions. We have examined experimentally a set of five compound semiconductors, cadmium telluride (CdTe), gallium arsenide (GaAs), gallium phosphide (GaP), indium arsenide (InAs), and zinc selenide (ZnSe) and a high-κ dielectric material, hafnium oxide (HfO), in their response to argon cluster profiling. An experimentally determined HfO etch rate of 0.025 nm/min (3.95 × 10{sup −2} amu/atom in ion) for 6 keV Ar gas clusters is used in the depth scale conversion for the profiles of the semiconductor materials. The assumption has been that, since the damage introduced into polymer materials is low, even though sputter yields are high, then there is little likelihood of damaging inorganic materials at all with cluster ions. This seems true in most cases; however, in this work, we report for the first time that this damage can in fact be very significant in the case of InAs, causing the formation of metallic indium that is readily visible even to the naked eye.

36 MATERIALS SCIENCE↗

Derivation of effective penetration depth of femtosecond laser pulses in metal from ablation rate dependence on laser fluence, incidence angle, and polarization

Ablation rate dependence on laser fluence for copper subjected to oblique femtosecond laser irradiation has been determined experimentally in order to investigate processing induced by oblique irradiation. A difference of ablation rate between p-polarized and s-polarized oblique irradiation is clearly observed. Effective penetration depth is defined to explain the ablation rate dependence instead of using optical penetration depth, which is treated as a key value for determining the ablation rate in conventional theory. The effective penetration depth for copper is presented in simple formulas as a function of laser incidence angle for each polarization.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Crack depth profiling using guided wave angle dependent reflectivity

Tomographic corrosion monitoring techniques have been developed, using two rings of sensors around the circumference of a pipe. This technique is capable of providing a detailed wall thickness map, however this might not be the only type of structural damage. Therefore this concept is expanded to detect and size cracks and small corrosion defects like root corrosion. The expanded concept uses two arrays of guided-wave transducers, collecting both reflection and transmission data. The data is processed such that the angle-dependent reflectivity is obtained without using a baseline signal of a defect-free situation. The angle-dependent reflectivity is the input of an inversion scheme that calculates a crack depth profile. From this profile, the depth and length of the crack can be determined. Preliminary experiments show encouraging results. The depth sizing accuracy is in the order of 0.5 mm.

42 ENGINEERING↗

Depth profile characterization with noncollinear beam mixing

Noncollinear beam mixing is an ultrasonic approach to quantify elastic nonlinearity within a subsurface volume of material. The technique requires interaction between two beams of specific frequency, angle, and vibration mode to generate a third beam propagating from the intersection volume. The subsurface depth to interaction zone is controlled by changing the separation distance between the two input transducers, and the amplitude of the third generated beam is proportional to the elastic nonlinearity within the interaction zone. Therefore, depth profiling is possible if a suitable parameter is established to normalize the detected signal independent of propagation distances and input amplitudes. This foundational effort has been conducted toward developing such a parameter for depth profile measurements in homogeneous aluminum that includes corrective terms for attenuation, beam overlap noise, beam spread, and input amplitudes. Experimental and analytical results are provided, and suggested applications and improvements are discussed toward characterizing subsurface material property profiles.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Long range surface plasmon resonance with ultra-high penetration depth for self-referenced sensing and ultra-low detection limit using diverging beam approach

Using an insulator-metal-insulator structure with dielectric having refractive index (RI) larger than the analyte, long range surface plasmon (SP) resonance exhibiting ultra-high penetration depth is demonstrated for sensing applications of large bioentities at wavelengths in the visible range. Based on the diverging beam approach in Kretschmann-Raether configuration, one of the SP resonances is shown to shift in response to changes in the analyte RI while the other is fixed; thus, it can be used as a built in reference. The combination of the high sensitivity, high penetration depth and self-reference using the diverging beam approach in which a dark line is detected of the high sensitivity, high penetration depth, self-reference, and the diverging beam approach in which a dark line is detected using large number of camera pixels with a smart algorithm for sub-pixel resolution, a sensor with ultra-low detection limit is demonstrated suitable for large bioentities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

STARSPOTS-TRANSIT DEPTH RELATION OF THE EVAPORATING PLANET CANDIDATE KIC 12557548b

Violent variation of transit depths and an ingress-egress asymmetry of the transit light curve discovered in KIC 12557548 have been interpreted as evidence of a catastrophic evaporation of atmosphere with dust ( M-dot {sub p}∼>1 M{sub ⊕} Gyr{sup –1}) from a close-in small planet. To explore what drives the anomalous atmospheric escape, we perform time-series analysis of the transit depth variation of Kepler archival data for ∼3.5 yr. We find a ∼30% periodic variation of the transit depth with P {sub 1} = 22.83 ± 0.21 days, which is within the error of the rotation period of the host star estimated using the light curve modulation, P {sub rot} = 22.91 ± 0.24 days. We interpret the results as evidence that the atmospheric escape of KIC 12557548b correlates with stellar activity. We consider possible scenarios that account for both the mass loss rate and the correlation with stellar activity. X-ray and ultraviolet (XUV)-driven evaporation is possible if one accepts a relatively high XUV flux and a high efficiency for converting the input energy to the kinetic energy of the atmosphere. Star-planet magnetic interaction is another possible scenario, though huge uncertainty remains for the mass loss rate.

79 ASTRONOMY AND ASTROPHYSICS↗

Depth-Dependent Critical Behavior in V2H

Using x-ray diffuse scattering, we investigate the critical behavior of an order-disorder phase transition in a defective 'skin layer' of V{sub 2}H. In the skin layer, there exist walls of dislocation lines oriented normal to the surface. The density of dislocation lines within a wall decreases continuously with depth. We find that, because of this inhomogeneous distribution of defects, the transition effectively occurs at a depth-dependent local critical temperature. A depth-dependent scaling law is proposed to describe the corresponding critical ordering behavior.

36 MATERIALS SCIENCE↗

Nonexponential London Penetration Depth of FeAs-Based Superconducting RFeAsO[subscript 0.9]F[subscript 0.1] (R=La, Nd) Single Crystals

The superconducting penetration depth {lambda}(T) has been measured in RFeAsO{sub 0.9}F{sub 0.1} (R=La, Nd) single crystals (R-1111). In Nd-1111, we find an upturn in {lambda}(T) upon cooling and attribute it to the paramagnetism of the Nd ions, similar to the case of the electron-doped cuprate Nd-Ce-Cu-O. After the correction for paramagnetism, the London penetration depth variation is found to follow a power-law behavior, {Delta}{lambda}L(T) {proportional_to} T{sup 2} at low temperatures. The same T{sup 2} variation of {lambda}(T) was found in nonmagnetic La-1111 crystals. Analysis of the superfluid density and of penetration depth anisotropy over the full temperature range is consistent with two-gap superconductivity. Based on this and on our previous work, we conclude that both the RFeAsO (1111) and BaFe{sub 2}As{sub 2} (122) families of pnictide superconductors exhibit unconventional two-gap superconductivity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

ODDS: Real-Time Object Detection Using Depth Sensors on Embedded GPUs

Detecting objects that are carried when someone enters or exits a room is very useful for a wide range of smart building applications including safety, security, and energy efficiency. While there has been a significant amount of work on object recognition using large-scale RGB image datasets, RGB cameras are too privacy invasive in many smart building applications and they work poorly in the dark. Additionally, deep object detection networks require powerful and expensive GPUs. We propose a novel system that we call ODDS (Object Detector using a Depth Sensor) that can detect objects in real-time using only raw depth data on an embedded GPU, e.g., NVIDIA Jetson TX1. Hence, our solution is significantly less privacy invasive (even if the sensor is compromised) and less expensive, while maintaining a comparable accuracy with state of the art solutions. Specifically, we resort to training a deep convolutional neural network using raw depth images, with curriculum based learning to improve accuracy by considering the complexity and imbalance in object classes and developing a sparse coding based technique that speeds up the system ~2× with minimal loss of accuracy. Based on a complete implementation and real-world evaluation, we see ODDS achieve 80.14% mean average precision in object detection in real-time (5-6 FPS) on a Jetson TX1.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Real-Time Fine Grained Occupancy Estimation Using Depth Sensors on ARM Embedded Platforms

Occupancy estimation is an important primitive for a wide range of applications including building energy efficiency, safety, and security. In this paper, we explore the potential of using depth sensors to detect, estimate, identify, and track occupants in buildings. While depth sensors have been widely used for human detection and gesture recognition, computer vision algorithms are typically run on a powerful computer like XBOX or Intel R CoreTM i7 processor. In this work, we develop a prototype system called FORK using off-the-shelf components that performs the entire depth data processing on a cheaper and low power ARM processor in real-time. As ARM processors are extremely weak in running computer vision algorithms, FORK is designed to detect humans and track them in a very efficient way by leveraging a novel lightweight model based approach instead of traditional approaches based on histogram of oriented gradients (HOG) features. Unlike other camera based approaches, FORK is much less privacy invasive (even if the sensor is compromised). Based on a complete implementation, real-world deployment, and extensive evaluation at realistic scenarios, we observe that FORK achieves over 99% accuracy in real-time (4-9 FPS) in occupancy estimation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Migration depths of adult steelhead Oncorhynchus mykiss in relation to dissolved gas supersaturation in a regulated river system

Adult steelhead tagged with archival transmitters primarily migrated through a large river corridor at depths > 2 m, interspersed with frequent but short (< 5 min) periods closer to the surface. The recorded swimming depths and behaviours probably provided adequate hydrostatic compensation for the encountered supersaturated dissolved gas conditions and probably limited development of gas bubble disease (GBD). Results parallel those from a concurrent adult Chinook salmon study, except steelhead experienced greater seasonal variability and were more likely to have depth-uncompensated supersaturation exposure in some dam tailraces, perhaps explaining the higher incidence of GBD in this species.

13 HYDRO ENERGY↗

High resolution depth profiling using near-total-reflection hard x-ray photoelectron spectroscopy

By adjusting the incidence angle of incoming x rays near the critical angle of x-ray total reflection, photoelectron intensity is strongly modulated due to the variation of x-ray penetration depth. Photoelectron spectroscopy combined with near-total reflection exhibits tunable surface sensitivity, providing depth-resolved information. In this Review, we first describe the experimental setup and specific data analysis process. We then review three different examples that show the broad application of this method. Furthermore, the emphasis is on its applications correlated to oxide heterostructures, especially quantitative depth analyses of compositions and electronic states. In the last part, we discuss the limitations of this technique, mostly in terms of the range of samples that can be studied.

36 MATERIALS SCIENCE↗

SU-E-T-93: Activation of Psoralen at Depth Using Kilovoltage X-Rays: Physics Considerations in Implementing a New Teletherapy Paradigm

Purpose: Psoralen is a UV-light activated anti-cancer biotherapeutic used for treating skin lesions (PUVA) and advanced cutaneous T-cell lymphoma (ECP). To date psoralen has not been used to treat deep seated tumors due to difficulty in generating UV-light at depth. We recently demonstrated psoralen activation at depth by introducing energy converting particles that absorb kV x-ray radiation and re-emit UV-light. Our in-vitro work found that 0.2–1Gy using 40–100kVp x-rays combined with psoralen and particles can induce a substantial apoptotic response beyond that expected from the sum of individual components. In preparation for a phase I clinical trial of canine companion animals, we address the physics and dosimetry considerations for applying this new teletherapy paradigm to an in-vivo setting. Methods: The kV on-board imaging (OBI) system mounted on a medical linear accelerator (Varian) was commissioned to deliver the prescribed dose (0.6Gy) using 80 and 100kVp. Dosimetric measurements included kVp, HVL, depth dose, backscatter factors, collimator and phantom scatter factors, field size factors, and blade leakage. Absolute dosimetry was performed following AAPM TG61 recommendations and verified with an independent kV dose meter. We also investigated collimated rotational delivery to minimize skin dose using simple dose calculations on homogeneous cylindrical phantoms. Results: Single beam delivery is feasible for shallow targets (<5cm) without exceeding skin tolerance, while a rotational delivery may be utilized for deeper targets; skin dose is ∼75% of target dose for 80kVp collimated rotational delivery to a 3cm target within a 20cm phantom. Heat loading was tolerable; 0.6Gy to 5cm can be delivered before the anode reaches 75% capacity. Conclusion: KV teletherapy for Psoralen activation in deep seated tissue was successfully commissioned for a Varian OBI machine for use in a phase I clinical trial in canines. Future work will use Monte Carlo dosimetry to investigate dose in presence of bone. Research funded by Immunolight LLC. H. Walder, Z. Fathi, & W. Beyer are employees of Immunolight LLC which holds a patent on the technology. Drs. Adamson and Oldham are consultants to Immunolight LLC.

60 APPLIED LIFE SCIENCES↗

SU-E-T-678: Response Calibration Using Electron Depth-Dose Data for MRI-Based 3D Polymer Gel Dosimetry

Purpose: To evaluate a calibration method using the depth-dose data of an electron beam for MRI-based polymer gel dosimetry. Methods: MAGAT was manufactured in-house to fill two 400mL-cylindrical phantoms and nine 22mL-glass vials. Phantom-A was irradiated along the cylinder axis with a 9MeV electron beam of 6 cm x 6 cm field size (FS). Phantom-B was irradiated with a 6MV photon beam of 3 cm x 3 cm FS by a 360-degree arc technique. Eight vials were irradiated in a water-bath to various doses with a 20 cm x 20 cm FS 6MV photon beam. All irradiated phantoms and one un-irradiated vial were scanned with a 3T MRI scanner to obtain the spin-spin relaxation rate (R2) distributions. By comparing the measured R2-to-depth data with the known depth-dose data for Phantom-A, R2-to-dose calibration data were obtained (e-beam method). Another calibration data were obtained from the 9 vials data (9-vial method). We tested two regression equations, i.e., third-order polynomial and tangent functions, and two dose normalization methods, i.e., one-point and two-point methods. Then, these two calibration methods were used to obtain the 3D dose distribution of Phantom-B and evaluated by comparing the measured data with the dose distribution from a treatment planning system. The comparison was made with gamma passing rate (2%/2mm criteria). Results: We did not observe a clear advantage of the e-beam method over the 9-vial method for the 3D dose comparison with the test case. Nevertheless, we found that the e-beam method required a smaller dose scaling for the dose comparison. Furthermore, the tangent function showed better data fitting than the polynomial function with smaller uncertainty of the estimated coefficients. Conclusions: Considering the overall superior performance, we recommend the e-beam method with the tangent function as the regression equation and one-point dose normalization for the MRI-based polymer gel dosimetry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Influence of soil depth, irrigation, and plant genotype on the soil microbiome, metaphenome, and carbon chemistry

ABSTRACT Climate change is causing an increase in drought in many soil ecosystems and a loss of soil organic carbon. Calcareous soils may partially mitigate these losses via carbon capture and storage. Here, we aimed to determine how irrigation-supplied soil moisture and perennial plants impact biotic and abiotic soil properties that underpin deep soil carbon chemistry in an unfertilized calcareous soil. Soil was sampled up to 1 m in depth from irrigated and planted field treatments and was analyzed using a suite of omics and chemical analyses. The soil microbial community composition was impacted more by irrigation and plant cover treatments than by soil depth. By contrast, metabolomes, lipidomes, and proteomes differed more with soil depth than treatments. Deep soil (>50 cm) had higher soil pH and calcium concentrations and higher levels of organic acids, bicarbonate, and triacylglycerides. By contrast, surface soil (0–5 cm) had higher concentrations of soil organic matter, organic carbon, oxidizable carbon, and total nitrogen. Surface soils also had higher amounts of sugars, sugar alcohols, phosphocholines, and proteins that reflect osmotic and oxidative stress responses. The lipidome was more responsive to perennial tall wheatgrass treatments compared to the metabolome or proteome, with a striking change in diacylglyceride composition. Permanganate oxidizable carbon was more consistently correlated to metabolites and proteins than soil organic and inorganic carbon and soil organic matter. This study reveals specific compounds that reflect differences in organic, inorganic, and oxidizable soil carbon fractions that are impacted by interactions between irrigation-supplied moisture and plant cover in calcareous soil profiles. IMPORTANCE Carbon is cycled through the air, plants, and belowground environment. Understanding soil carbon cycling in deep soil profiles will be important to mitigate climate change. Soil carbon cycling is impacted by water, plants, and soil microorganisms, in addition to soil mineralogy. Measuring biotic and abiotic soil properties provides a perspective of how soil microorganisms interact with the surrounding chemical environment. This study emphasizes the importance of considering biotic interactions with inorganic and oxidizable soil carbon in addition to total organic carbon in carbonate-containing soils for better informing soil carbon management decisions.

59 BASIC BIOLOGICAL SCIENCES↗

Сomposition Depth Profiling of the GaAs Native Oxide Irradiated by an Ar{sup +} Ion Beam

The elemental and chemical compositions throughout the thickness of the GaAs native oxide layer slightly irradiated by Ar{sup +} ions have been studied by synchrotron-based photoelectron spectroscopy at different photon energies enabling variation of probing depth. The presence of only two phases was observed: of the gallium oxide Ga{sub 2}O{sub 3} and elementary arsenic As{sup o} generated due to complete decay of arsenic oxides under the ion irradiation. Depth composition profiles were determined nondestructively. Despite inhomogeneous depth distribution, these profiles demonstrated domination (90 at %) of the dielectric Ga{sub 2}O{sub 3} phase virtually throughout all the oxide thickness (~2 nm).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Data depth based clustering analysis

Here, this paper proposes a new algorithm for identifying patterns within data, based on data depth. Such a clustering analysis has an enormous potential to discover previously unknown insights from existing data sets. Many clustering algorithms already exist for this purpose. However, most algorithms are not affine invariant. Therefore, they must operate with different parameters after the data sets are rotated, scaled, or translated. Further, most clustering algorithms, based on Euclidean distance, can be sensitive to noises because they have no global perspective. Parameter selection also significantly affects the clustering results of each algorithm. Unlike many existing clustering algorithms, the proposed algorithm, called data depth based clustering analysis (DBCA), is able to detect coherent clusters after the data sets are affine transformed without changing a parameter. It is also robust to noises because using data depth can measure centrality and outlyingness of the underlying data. Further, it can generate relatively stable clusters by varying the parameter. The experimental comparison with the leading state-of-the-art alternatives demonstrates that the proposed algorithm outperforms DBSCAN and HDBSCAN in terms of affine invariance, and exceeds or matches the ro-bustness to noises of DBSCAN or HDBSCAN. The robust-ness to parameter selection is also demonstrated through the case study of clustering twitter data.

58 GEOSCIENCES↗

Dataset: Occupancy Detection, Tracking, and Estimation Using a Vertically Mounted Depth Sensor

Occupancy detection, tracking, and estimation has a wide range of applications including improving building energy efficiency, safety, and security of the occupants. As depth sensors are getting cheaper, they offer a viable solution to estimate occupancy accurately in a non-privacy invasive manner. Even though there are publicly available depth datasets, they do not consider placing the sensor in the ceiling looking downwards to estimate occupancy. We deployed four Kinect for XBOX One in four CMU classrooms and conference rooms for a period of four weeks in 2017 and collected over 6 TB of depth data. We annotate this huge dataset by labelling bounding boxes around occupants and release the annotated dataset.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗