Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DC power distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Highly Efficient Amplifier for Ka-Band Communications

An amplifier developed under a Small Business Innovation Research (SBIR) contract will have applications for both satellite and terrestrial communications. This power amplifier uses an innovative series bias arrangement of active devices to achieve over 40-percent efficiency at Ka-band frequencies with an output power of 0.66 W. The amplifier is fabricated on a 2.0- by 3.8-square millimeter chip through the use of Monolithic Microwave Integrated Circuit (MMIC) technology, and it uses state-of-the-art, Pseudomorphic High-Electron-Mobility Transistor (PHEMT) devices. Although the performance of the MMIC chip depends on these high-performance devices, the real innovations here are a unique series bias scheme, which results in a high-voltage chip supply, and careful design of the on-chip planar output stage combiner. This design concept has ramifications beyond the chip itself because it opens up the possibility of operation directly from a satellite power bus (usually 28 V) without a dc-dc converter. This will dramatically increase the overall system efficiency. Conventional microwave power amplifier designs utilize many devices all connected in parallel from the bias supply. This results in a low-bias voltage, typically 5 V, and a high bias current. With this configuration, substantial I(sup 2) R losses (current squared times resistance) may arise in the system bias-distribution network. By placing the devices in a series bias configuration, the total current is reduced, leading to reduced distribution losses. Careful design of the on-chip planar output stage power combiner is also important in minimizing losses. Using these concepts, a two-stage amplifier was designed for operation at 33 GHz and fabricated in a standard MMIC foundry process with 0.20-m PHEMT devices. Using a 20-V bias supply, the amplifier achieved efficiencies of over 40 percent with an output power of 0.66 W and a 16-dB gain over a 2-GHz bandwidth centered at 33 GHz. With a 28-V bias, a power level of 1.1 W was achieved with a 12-dB gain and a 36-percent efficiency. This represents the best reported combination of power and efficiency at this frequency. In addition to delivering excellent power and gain, this Ka-band MMIC power amplifier has an efficiency that is 10 percent greater than existing designs. The unique design offers an excellent match for spacecraft applications since the amplifier supply voltage is closely matched to the typical value of spacecraft bus voltage. These amplifiers may be used alone in applications of 1 W or less, or several may be combined or used in an array to produce moderate power, Ka-band transmitters with minimal power combining and less thermal stress owing to the combination of excellent efficiency and power output. The higher voltage operation of this design may also save mass and power because the dc-dc power converter is replaced with a simpler voltage regulator.

Source record↗

Harnessing distributed GPU computing for generalizable graph convolutional networks in power grid reliability assessments

Although machine learning (ML) has emerged as a powerful tool for rapidly assessing grid contingencies, prior studies have largely considered a static grid topology in their analyses. This limits their application, since they need to be re-trained for every new topology. Here, this paper explores the development of generalizable graph convolutional network (GCN) models by pre-training them across a range of grid topologies and contingency types. We found that a GCN model with auto-regressive moving average (ARMA) layers with a line graph representation of the grid offered the best predictive performance in predicting voltage magnitudes (VM) and voltage angles (VA). We introduced the concept of phantom nodes to consider disparate grid topologies with a varying number of nodes and lines. For pre-training the GCN ARMA model across a variety of topologies, distributed graphics processing unit (GPU) computing afforded us significant training scalability. The predictive performance of this model on grid topologies that were part of the training data is substantially better than the direct current (DC) approximation. Although direct application of the pre-trained model to topologies that are not part of the grid is not particularly satisfactory, fine-tuning with small amounts of data from a specific topology of interest significantly improves predictive performance. In general, this paper highlights the feasibility of training large-scale GNN models to assess the reliability of power grids by considering a wide variety of grid topologies and contingency types. With the advent of foundational models in ML and the exponential increase in GPU computing clusters, generalizable ML models will significantly enhance how utilities manage power systems and make decisions in real-time or near-real-time.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Modular Wide-bandgap String Inverters for Low-cost Medium-voltage Transformerless PV Systems

The proposed technology combines advances in wide-bandgap power electronics with breakthroughs in distributed and decentralized control to produce ultra-low-cost medium-voltage transformerless PV inverters that are composed of stackable lightweight blocks. Taken together, the proposed circuit designs and accompanying control strategies will yield integrated control+circuit (C2) blocks, each comprising a converter and local controller, that can be assembled in a modular fashion to obtain distributed conversion interfaces for next-generation commercial and utility-scale PV systems. We will utilize SiC devices to obtain C2 blocks that can individually operate at a voltage and power in excess of 1 kV and 100 kW, respectively, such that ensembles of series-connected blocks perform direct dc to three-phase ac conversion at medium voltages (e.g., 12 kV–35 kV) and at multi-MW power levels.

42 ENGINEERING↗

New options for satellite power systems /SPS/

The operation of a satellite power system (SPS) involves the conversion of solar energy into electrical energy with the aid of facilities carried by a geosynchronous satellite, the transmission of the obtained energy to earth in the form of microwave radio frequency energy, and the conversion of the energy received on earth into dc current for distribution into the network. Attention is given to questions concerning suitable microwave radiation density, details of space transportation for the construction of the SPS, and suitable approaches for the transformation of the solar energy into electric energy. It appears that a Rankine cycle using cesium as the main working fluid and a steam bottoming cycle might have advantages over a Brayton cycle concept considered earlier. In the area of solar photovoltaic concepts GaAlAs cells have advantages over silicon cells related to lighter weight, efficiency, and resistance to space radiation. The required amount of gallium seems to become available.

Hanley, G. M.↗

Energy considerations regarding pulsed arc production of nanomaterials

Atmospheric arc discharge volumes have been estimated from the light distribution emitted during evaporation of graphite and molybdenum disulphide (MoS 2 ) anodes. These data have been correlated to the peak power in the case of pulsed arc discharge held at different frequencies (1, 2 and 5 Hz). The measured power density values and the corresponding specific energies per particle have been compared to DC values, and showed that pulsed arc discharges deliver electrical power more efficiently than DC arc discharges do with yet lower thermal loads. In particular, the power density of ≈1 kW/cm 3 characteristic of pulsed arcs (10-20 kW/cm 3 in DC) suffices to provide 15 eV/particle to the arc plasma (≈10 eV/particle or less in DC). Such an energy balance resulted in high ionization rates of the ablated material and production yields of carbon nanotubes around 10 11 cm -2 kWh -1 . Lastly, in situ probe experiments showed that pulsed arcs enhance the transport to substrate of the generated nanoparticles, such as graphene and MoS 2 monolayers. Pulsed anodic arcs open the possibility to generate further nanomaterials thanks to a more rational power investment and a better control of the discharge region.

42 ENGINEERING↗

Modular HF Isolated MV String Inverters Enable a New Paradigm for Large PV Farms

The “Modular HF Isolated MV String Inverters Enable a New Paradigm for Large PV Farms” project focuses on exploring alternative power converter and system-level plant configurations to achieve the lowest cost and highest energy output for a given solar plus storage (e.g., PV + battery) plant, including the use of medium voltage (MV) collection while taking into account detailed models of all elements. To realize this objective, four approaches were utilized (i) employ a novel Medium Voltage String Inverter (MVSI) topology (soft switching solid state transformer – S4T) to convert 1000 Vdc to 4.16 kVac; (ii) plant collection using standard, low-cost overhead MV distribution network; (iii) enable energy storage integration without additional converter cost to achieve dispatchability of the PV resource; and (iv) provide advanced functionality (autonomous operation, track ISO signals for dynamic balancing and ancillary services, and PV farm operation as a virtual grid resource). Subsequently and in alignment with the previously mentioned approaches, the project was structured in five efforts (i) S4T MVSI simulation and design; (ii) system analysis and storage optimization; (iii) financial analysis; (iv) power converter prototype build and test; and (v) regulatory and commercial impact study. The outcomes provided by each effort can be summarized as follows (i) Project explored the use of MV AC distribution architecture for hybrid PV+storage utility-scale PV farms; (ii) Detailed loss and LCOE analysis for AC and DC side BESS architecture, including multiple converter topologies, as well as for proposed MVSI/MDCT systems; (iii) MVSI was built and holds promise but needs lower-cost high-voltage Si-C devices, which does not seem possible in the near term; (iv) MDCT provides a simpler modular building block – validated through HIL and farm level modeling, simulation and experimental validation; (v) 300 kVA MDCT prototype built and tested, technology is being commercialized; and (vi) Regulatory model of utility building PV plants, where PV panels are treated as DC generation (IPP), seems viable and can allow improved grid integration.

14 SOLAR ENERGY↗

Energy Systems Integration Facility (ESIF): World-Class Systems Integration Capabilities and Research

The Energy Systems Integration Facility (ESIF), located at the National Renewable Energy Laboratory (NREL) South Table Mountain campus, is a world-renowned user facility for research and development of modern, advanced, and clean energy technologies. ESIF is distinguished by its continuously evolving, highly integrated systems that span throughout the building, connecting research capabilities across multiple laboratories and test areas. The primary ESIF research systems include: [1] data, cyber, and control networks, [2] research electrical distribution buses (REDB), [3] thermal integration infrastructure, and [4] hydrogen systems. The data, cyber, and control networks provide monitoring, control, communication, automation, visualization, and time series data storage and tagging capabilities for research projects and ESIF systems, including facility safety functions. The REDB system consists of four dedicated AC and DC electrical power networks that can connect devices located across the facility through versatile, automatic circuit configuration to support complex power electronics experiments up to the megawatt-scale. The thermal integration infrastructure consists of three temperature-conditioned water loops that provide heating and cooling interfaces and capabilities for thermal energy research. The hydrogen systems provide megawatt-scale hydrogen production, drying, compression, high-pressure storage, and delivery to laboratory end uses, including hydrogen fuel cell vehicle fueling. The ESIF research systems interconnect and extend throughout the various lab areas of the facility to create elaborate networks composed of diverse technologies for cutting-edge research. The ESIF capabilities are operated and stewarded by the ESIF Research Operations group, who also actively upgrade and advance the systems to ensure they remain ahead of anticipated research - enabling the success of many pioneering energy integration projects. The poster, created by members of the ESIF Research Operations team, highlights and summarizes the four core integrated systems at ESIF. The poster was first presented at the internal NREL Energize Forum on May 13th, 2024, and received the "Best Poster" award.

capabilities↗

Space station common module network topology and hardware development

Conceptual space station common module power management and distribution (SSM/PMAD) network layouts and detailed network evaluations were developed. Individual pieces of hardware to be developed for the SSM/PMAD test bed were identified. A technology assessment was developed to identify pieces of equipment requiring development effort. Equipment lists were developed from the previously selected network schematics. Additionally, functional requirements for the network equipment as well as other requirements which affected the suitability of specific items for use on the Space Station Program were identified. Assembly requirements were derived based on the SSM/PMAD developed requirements and on the selected SSM/PMAD network concepts. Basic requirements and simplified design block diagrams are included. DC remote power controllers were successfully integrated into the DC Marshall Space Flight Center breadboard. Two DC remote power controller (RPC) boards experienced mechanical failure of UES 706 stud-mounted diodes during mechanical installation of the boards into the system. These broken diodes caused input to output shorting of the RPC's. The UES 706 diodes were replaced on these RPC's which eliminated the problem. The DC RPC's as existing in the present breadboard configuration do not provide ground fault protection because the RPC was designed to only switch the hot side current. If ground fault protection were to be implemented, it would be necessary to design the system so the RPC switched both the hot and the return sides of power.

Anderson, P.↗

Managing Workplace Charging: Argonne National Laboratory’s Reservation-Based Smart EV Charging Platform

The Smart Electric Power Alliance (SEPA) partnered with Argonne National Laboratory (Argonne) to produce a case study on Argonne’s workplace electric vehicle (EV) charging program, designed to optimize employees’ ability to reserve EV chargers and allow Argonne to implement a workplace managed charging solution. Formally known as EVrez, the program offers Argonne’s employees access to more than 50 Level 2 chargers and 4 DC fast chargers (DCFC). Employees must reserve and manage their EV sessions through the EVrez mobile app platform. This report outlines the EVrez program, from inception to maturity, highlighting key learnings and best practices from the Argonne team. As other workplaces seek to offer their own workplace charging offerings, this report highlights foundational steps and considerations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sail GTS ground system analysis: Avionics system engineering

A comparison of two different concepts for the guidance, navigation and control test set signal ground system is presented. The first is a concept utilizing a ground plate to which crew station, avionics racks, electrical power distribution system, master electrical common connection assembly and marshall mated elements system grounds are connected by 4/0 welding cable. An alternate approach has an aluminum sheet interconnecting the signal ground reference points between the crew station and avionics racks. The comparison analysis quantifies the differences between the two concepts in terms of dc resistance, ac resistance and inductive reactance. These parameters are figures of merit for ground system conductors in that the system with the lowest impedance is the most effective in minimizing noise voltage. Although the welding cable system is probably adequate, the aluminum sheet system provides a higher probability of a successful system design.

Lawton, R. M.↗

Light extinction by aerosols during summer air pollution

In order to utilize satellite measurements of optical thickness over land for estimating aerosol properties during air pollution episodes, the optical thickness was measured from the surface and investigated. Aerosol optical thicknesses have been derived from solar transmission measurements in eight spectral bands within the band lambda 440-870 nm during the summers of 1980 and 1981 near Washington, DC. The optical thicknesses for the eight bands are strongly correlated. It was found that first eigenvalue of the covariance matrix of all observations accounts for 99 percent of the trace of the matrix. Since the measured aerosol optical thickness was closely proportional to the wavelength raised to a power, the aerosol size distribution derived from it is proportional to the diameter (d) raised to a power for the range of diameters between 0.1 to 1.0 micron. This power is insensitive to the total optical thickness. Changes in the aerosol optical thickness depend on several aerosol parameters, but it is difficult to identify the dominant one. The effects of relative humidity and accumulation mode concentration on the optical thickness are analyzed theoretically, and compared with the measurements.

Kaufman, Y. J.↗

Parallel arrays of Josephson junctions for submillimeter local oscillators

In this paper we discuss the influence of the DC biasing circuit on operation of parallel biased quasioptical Josephson junction oscillator arrays. Because of nonuniform distribution of the DC biasing current along the length of the bias lines, there is a nonuniform distribution of magnetic flux in superconducting loops connecting every two junctions of the array. These DC self-field effects determine the state of the array. We present analysis and time-domain numerical simulations of these states for four biasing configurations. We find conditions for the in-phase states with maximum power output. We compare arrays with small and large inductances and determine the low inductance limit for nearly-in-phase array operation. We show how arrays can be steered in H-plane using the externally applied DC magnetic field.

Pance, Aleksandar↗

Isotope engineering for spin defects in van der Waals materials

Abstract Spin defects in van der Waals materials offer a promising platform for advancing quantum technologies. Here, we propose and demonstrate a powerful technique based on isotope engineering of host materials to significantly enhance the coherence properties of embedded spin defects. Focusing on the recently-discovered negatively charged boron vacancy center ($${{{{{{{{\rm{V}}}}}}}}}_{{{{{{{{\rm{B}}}}}}}}}^{-}$$ V B − ) in hexagonal boron nitride (hBN), we grow isotopically purified h 10 B 15 N crystals. Compared to$${{{{{{{{\rm{V}}}}}}}}}_{{{{{{{{\rm{B}}}}}}}}}^{-}$$ V B − in hBN with the natural distribution of isotopes, we observe substantially narrower and less crowded$${{{{{{{{\rm{V}}}}}}}}}_{{{{{{{{\rm{B}}}}}}}}}^{-}$$ V B − spin transitions as well as extended coherence timeT 2 and relaxation timeT 1 . For quantum sensing,$${{{{{{{{\rm{V}}}}}}}}}_{{{{{{{{\rm{B}}}}}}}}}^{-}$$ V B − centers in our h 10 B 15 N samples exhibit a factor of 4 (2) enhancement in DC (AC) magnetic field sensitivity. For additional quantum resources, the individual addressability of the$${{{{{{{{\rm{V}}}}}}}}}_{{{{{{{{\rm{B}}}}}}}}}^{-}$$ V B − hyperfine levels enables the dynamical polarization and coherent control of the three nearest-neighbor 15 N nuclear spins. Our results demonstrate the power of isotope engineering for enhancing the properties of quantum spin defects in hBN, and can be readily extended to improving spin qubits in a broad family of van der Waals materials.

Science & Technology - Other Topics↗

Fault Current Control and Protection in a Standalone DC Microgrid Using Adaptive Droop and Current Derivative

This report presents a novel fault detection, characterization, and fault current control algorithm for a standalone solar-photovoltaic (PV) based dc microgrids. The protection scheme is based on the current derivative algorithm. The overcurrent and current directional/differential comparison based protection schemes are incorporated for the dc microgrid fault characterization. For a low impedance fault, the fault current is controlled based on the current/voltage thresholds and current direction. Generally, the droop method is used to control the power-sharing between the converters by controlling the reference voltage. In this article, an adaptive droop scheme is also proposed to control the fault current by calculating a virtual resistance R droop , and to control the converter output reference voltage. For a high impedance fault, differential comparison method is used to characterize the fault. These algorithms effectively control the converter pulsewidth and reduce the flow of source current from a particular converter, which helps to increase the fault clearing time. Additionally, a trip signal is sent to the corresponding dc circuit breaker (DCCB), to isolate the faulted converter, feeder or a dc bus. The dc microgrid protection design procedure is detailed, and the performance of the proposed method is verified by simulation analysis.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis and design of DC-link capacitor in cascaded H-bridge multilevel active front-end converter

Medium-voltage grid-tied systems often use a cascaded H-bridge multi-level active front-end. In this converter, dc link bus capacitors play an important role in stabilizing the converter and enabling both active and reactive power injections. The present work provides analytical expressions for the capacitor current, which are essential for optimizing system design (especially capacitor size vs. lifetime). Then, the expression is incorporated into the grid connected bidirectional power system model. Consequently, this work contributes to the guiding principles to choose accurate dc link capacitor ratings against grid-side power delivery requirements. DC-link capacitors come with an expiration date which is dependent on the operating power and voltage values. Lack of information about the lifetime of the dc-link capacitor creates uncertainty in the duration of online operation of the converter, thus increasing the probability of a contingency outage. The lifetime of the capacitor can range from only a few seconds of online operation of the station due to under-sizing, to a compromised quality of power flowing through other solid state devices which may not have been designed for the transients that are caused by over-sizing of the dc-link capacitor. A better estimate of the lifetime of these capacitors can help maximize usage and maintain scheduled outages more efficiently, without disruption in service.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power conditioning for large dc motors for space flight applications

The design and performance of a prototype power-conditioning system for use with large brushless dc motors on NASA space missions are discussed in detail and illustrated with extensive diagrams, drawings, and graphs. The 5-kW 8-phase parallel module evaluated here would be suitable for use in the Space Shuttle Orbiter cargo bay. A current-balancing magnetic assembly with low distributed inductance permits high-speed current switching from a low-voltage bus as well as current balancing between parallel MOSFETs.

Veatch, Martin S.↗