Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Curved detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

The Challenges Ahead for Multimessenger Analyses of Gravitational Waves and Kilonova: A Case Study on GW190425

In recent years, there have been significant advances in multimessenger astronomy due to the discovery of the first, and so far only confirmed, gravitational wave event with a simultaneous electromagnetic (EM) counterpart, as well as improvements in numerical simulations, gravitational wave (GW) detectors, and transient astronomy. This has led to the exciting possibility of performing joint analyses of the GW and EM data, providing additional constraints on fundamental properties of the binary progenitor and merger remnant. Here, in this work, we present a new Bayesian framework that allows inference of these properties, while taking into account the systematic modeling uncertainties that arise when mapping from GW binary progenitor properties to photometric light curves. We extend the relative binning method presented in Zackay et al. to include extrinsic GW parameters for fast analysis of the GW signal. The focus of our EM framework is on light curves arising from r-process nucleosynthesis in the ejected material during and after merger, the so-called kilonova, and particularly on black hole–neutron star systems. As a case study, we examine the recent detection of GW190425, where the primary object is consistent with being either a black hole or a neutron star. We show quantitatively how improved mapping between binary progenitor and outflow properties, and/or an increase in EM data quantity and quality are required in order to break degeneracies in the fundamental source parameters.

79 ASTRONOMY AND ASTROPHYSICS↗

Multi-Parameter Nonlinear Gain Correction of X-Ray Transition Edge Sensors for the X-Ray Integral Field Unit

With its array of 3840 Transition Edge Sensors (TESs), the Athena X-ray Integral Field Unit (X-IFU) will provide spatially resolved high-resolution spectroscopy (2.5 eV up to 7 keV) from 0.2 to 12 keV, with an absolute energy scale accuracy of 0.4 eV. Slight changes in the TES operating environment can cause significant variations in its energy response function, which may result in systematic errors in the absolute energy scale. We plan to monitor such changes at pixel level via onboard X-ray calibration sources and correct the energy scale accordingly using a linear or quadratic interpolation of gain curves obtained during ground calibration. However, this may not be sufficient to meet the 0.4 eV accuracy required for the XIFU. In this contribution, we introduce a newtwo-parameter gain correction technique, based on both the pulse-height estimate of a fiducial line and the baseline value of the pixels. Using gain functions that simulate ground calibration data, we show that this technique can accurately correct deviations in detector gain due to changes in TES operating conditions such as heat sink temperature, bias voltage, thermal radiation loading and linear amplifier gain. We also address potential optimisations of the onboard calibration source and compare the performance of this new technique with those previously used.

Cucchetti, E.↗

Modelling the Soft X-Ray and EUV Emission in Classical Novae: EUVE and ROSAT Observations of V1974 Cygni

We have conducted an extensive analysis of the observability of Classical Novae with the EUVE Lex/B and Al/Ti/C detectors. Predicted count rates have been computed using optically thin, isothermal plasma models for solar and metal-rich compositions, and hot ONeMg white dwarf model atmospheres. We find EUVE to be quite sensitive to both the EUV and soft X-ray emission emitted by the underlying hot white dwarf during novae outbursts, except for the coolest temperatures with very high intervening hydrogen column density. These results are used to interpret the emission detected during the EUVE all-sky survey of Nova Cygni 1992 (approx. = V1974 Cyg), 279-290 days after visual maximum. We find the best fit to the observed emission from V1974 Cyg arises from a hot ONeMg white dwarf with surface temperature approx. 4 x l0(exp 5) K and a mas of approx. 1.2 solar mass, and derive an interstellar hydrogen column density of approx. 3 x 10(exp 21)/sq cm. Virtually all this emission arises from supersoft X-rays rather than the EUV. We also report the detection of V1974 Cyg with the EUVE Deep Survey detector at 549 days after visual maximum. This observation is compatible with the above properties, indicating that the mechanism responsible for the soft X-ray emission, connected with the underlying white dwarf, had not yet entirely turned off. We also present analysis of a ROSAT PSPC observation which is contemporaneous with the EUVE survey observations; this independently confirms the high column density we derived from the EUVE survey observation. Light curves for the EUVE and ROSAT observations are presented. Statistical tests for variability show that all of these observations are indeed highly variable over various time scales. The EUVE survey data shows one day variations, the EUVE DS data show approx. 30 minute fluctuations, while the ROSAT data vary rapidly on time scales of seconds. The EUVE data shows no periodic variability on any time scale. The implications of the rapid variability are briefly discussed.

Stringfellow, Guy S.↗

Differential Mobility Spectrometry: Preliminary Findings on Determination of Fundamental Constants

The electron capture detector (ECD) has been used for 40+ years (1) to derive fundamental constants such as a compound's electron affinity. Given this historical perspective, it is not surprising that differential mobility spectrometry (DMS) might be used in a like manner. This paper will present data from a gas chromatography (GC)-DMS instrument that illustrates the potential capability of this device to derive fundamental constants for electron-capturing compounds. Potential energy curves will be used to provide possible explanation of the data.

Limero, Thomas↗

Performance Analysis of a Hardware Implemented Complex Signal Kurtosis Radio-Frequency Interference Detector

Radio-frequency interference (RFI) is a known problem for passive remote sensing as evidenced in the L-band radiometers SMOS, Aquarius and more recently, SMAP. Various algorithms have been developed and implemented on SMAP to improve science measurements. This was achieved by the use of a digital microwave radiometer. RFI mitigation becomes more challenging for microwave radiometers operating at higher frequencies in shared allocations. At higher frequencies larger bandwidths are also desirable for lower measurement noise further adding to processing challenges. This work focuses on finding improved RFI mitigation techniques that will be effective at additional frequencies and at higher bandwidths. To aid the development and testing of applicable detection and mitigation techniques, a wide-band RFI algorithm testing environment has been developed using the Reconfigurable Open Architecture Computing Hardware System (ROACH) built by the Collaboration for Astronomy Signal Processing and Electronics Research (CASPER) Group. The testing environment also consists of various test equipment used to reproduce typical signals that a radiometer may see including those with and without RFI. The testing environment permits quick evaluations of RFI mitigation algorithms as well as show that they are implementable in hardware. The algorithm implemented is a complex signal kurtosis detector which was modeled and simulated. The complex signal kurtosis detector showed improved performance over the real kurtosis detector under certain conditions. The real kurtosis is implemented on SMAP at 24 MHz bandwidth. The complex signal kurtosis algorithm was then implemented in hardware at 200 MHz bandwidth using the ROACH. In this work, performance of the complex signal kurtosis and the real signal kurtosis are compared. Performance evaluations and comparisons in both simulation as well as experimental hardware implementations were done with the use of receiver operating characteristic (ROC) curves. The complex kurtosis algorithm has the potential to reduce data rate due to onboard processing in addition to improving RFI detection performance.

microwaves↗

Performance Analysis of a Hardware Implemented Complex Signal Kurtosis Radio-Frequency Interference Detector

Radio-frequency interference (RFI) is a known problem for passive remote sensing as evidenced in the L-band radiometers SMOS, Aquarius and more recently, SMAP. Various algorithms have been developed and implemented on SMAP to improve science measurements. This was achieved by the use of a digital microwave radiometer. RFI mitigation becomes more challenging for microwave radiometers operating at higher frequencies in shared allocations. At higher frequencies larger bandwidths are also desirable for lower measurement noise further adding to processing challenges. This work focuses on finding improved RFI mitigation techniques that will be effective at additional frequencies and at higher bandwidths. To aid the development and testing of applicable detection and mitigation techniques, a wide-band RFI algorithm testing environment has been developed using the Reconfigurable Open Architecture Computing Hardware System (ROACH) built by the Collaboration for Astronomy Signal Processing and Electronics Research (CASPER) Group. The testing environment also consists of various test equipment used to reproduce typical signals that a radiometer may see including those with and without RFI. The testing environment permits quick evaluations of RFI mitigation algorithms as well as show that they are implementable in hardware. The algorithm implemented is a complex signal kurtosis detector which was modeled and simulated. The complex signal kurtosis detector showed improved performance over the real kurtosis detector under certain conditions. The real kurtosis is implemented on SMAP at 24 MHz bandwidth. The complex signal kurtosis algorithm was then implemented in hardware at 200 MHz bandwidth using the ROACH. In this work, performance of the complex signal kurtosis and the real signal kurtosis are compared. Performance evaluations and comparisons in both simulation as well as experimental hardware implementations were done with the use of receiver operating characteristic (ROC) curves.

radiometers↗

Characterization of the response of radiochromic film to quasi-monoenergetic x rays through a cross-calibration with image plates

Radiochromic film (RCF) and image plates (IPs) are both commonly used detectors in diagnostics fielded at inertial confinement fusion (ICF) and high-energy-density physics (HEDP) research facilities. Due to the intense x-ray background in all ICF/HEDP experiments, accurately calibrating the optical density of RCF as a function of x-ray dose, and the photostimulated luminescence per photon of IPs as a function of x-ray energy, is necessary for interpreting experimental results. Various measurements of the sensitivity curve of different IPs to x rays have been performed [Izumi et al., Proc. SPIE 8850, 885006 (2013) and Rosenberg et al., Rev. Sci. Instrum. 90(1), 013506 (2019)]; however, calibrating RCF is a tedious process that depends on factors such as the orientation in which the RCF is scanned in the film scanner and the batch of RCF used. These issues can be mitigated by cross-calibrating RCF with IPs to enable the use of IPs for the determination of dose on the RCF without scanning the RCF. Here, the first cross-calibration of RCF with IPs to quasi-monoenergetic titanium, copper, and molybdenum K-line x rays is presented. It is found that the IP-inferred dose rates on the RCF for the Ti and Mo x rays agree well with the measured dose rates, while the IP-inferred dose rate for the Cu x rays is larger than the measured dose rate by ∼2×. Explanations for this discrepancy and plans for future work are discussed.

Instruments & Instrumentation↗

Diurnal Lightning Distributions as Observed by the Optical Transient Detector (OTD) and the Lightning Imaging Sensor (LIS)

Data obtained from the OTD (April 1995 to March 2000) and LIS (December 1997 to December 2005) satellites (70 and 35 degree inclination low earth orbits, respectively) are used to statistically determine the number of flashes in the diurnal cycle both as a function of local and universal time. Also included are global flash density maps. The data are further subdivided by season, continental versus oceanic, night time versus day time, northern versus southern hemisphere, and other regions of interest. The data include corrections for detection efficiency and instrument view time. The data are compared with both the "Carnegie Curve" and the diurnal global thunderstorm contributions from thunderday statistics from different continents, and are found to agree closely in phase and amplitude with the global thunderday statistics. The analysis also indicates that the southern hemisphere spring (September to November) has larger amplitude than the southern hemisphere fall (March to May). This may be due to differences in the contribution from the Brazilian rain forest during these periods. In general, as highlighted by a difference analysis, more lightning is observed in local springtime than the fall for continental locations, while oceanic regions display an opposite effect. For some areas of the world, the peak of diurnal curve appears to be shifted to later in the evening.

Bailey, Jeff C.↗

Preliminary Design of a New Pulsed-Neutron Die--Away Experiments with Absorbers (IER-552 CED-1)

This report presents the preliminary design (CED-1) of IER-552, pulsed-neutron die-away (PNDA) experiments with absorbers, to be conducted by Lawrence Livermore National Laboratory (LLNL). The goal of the PNDA experiments with absorbing materials is to produce high-quality, low-cost integral benchmarks that can be used to validate cross sections that are high priority nuclear data for the Department of Energy’s Nuclear Criticality Safety Program (NCSP). PNDA experiments can be used to generate nuclear data validation benchmarks quickly and cheaply, as they do not require fissile material or a nuclear facility to conduct them. The original PNDA experiments were set up at LLNL under IER-501. Extending the PNDA experiments to include absorbing materials leverages existing facilities and resources at LLNL to validate cross sections, with a basic experiment design that uses a neutron generator to impinge a short, mono-energetic neutron pulse on a poisoned, moderating target sample. The neutron pulse lasts 100 µs, after which the neutron population in the sample reaches thermal equilibrium and later spatial equilibrium. In this fully equilibrized state, the neutron population has a characteristic decay-time eigenvalue. The eigenvalue can be used as an integral parameter to validate nuclear data involved with neutron scattering and absorption. Two observables can be measured: the neutron population and the population of secondary γ-rays produced by inelastic and capture reactions. This report explores the feasibility of both approaches. For γ-ray measurements, this allows for direct measurement of reactions of interest for validation. During the neutron burst time, inelastic (prompt) γ-rays dominate, and these data can be isolated for validation of neutron inelastic scattering data. After the pulse ends, neutron capture (delayed) γ-rays dominate and are produced by many reaction channels as neutrons slow down to thermal energies. Two sets of γ-ray spectra (inelastic, capture) can be produced for validation. Additionally, the time-dependent decay of the capture γ-ray population when the neutron population is thermalized and in its fundamental mode can be used for validation. Two experiments can be imagined where pulsed neutrons are used to validate the nuclear data of absorbing materials. The first integrates well into the existing PNDA testbed at LLNL. The absorber material would be introduced into a moderating target and the same neutron generator, neutron detectors, electronics, and shielding box used for IER-501 would be employed. From the same experimental setup, many absorbing materials can be validated by simply changing the neutron poison in the moderator. The only significant modification would be the introduction of a γ-ray detector. Such an experiment would primarily serve to validate nuclear data in the thermal energy range. The second kind of experiment would validate the fast and epithermal energy range. It would involve pulsing neutron into a bare assembly of the absorber material and measuring the die-away of neutrons. The fast leakage of such an assembly requires nanosecond neutron-generator pulse widths and fast detectors/electronics that could measure ~200 ns die-away curves. This kind of experiment would ideally be performed at a cyclotron, like that available at Lawrence Berkeley National Laboratory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Discovery of a soft X-ray flux from AN Ursae Majoris

During November 1975, the soft X-ray detectors on the SAS 3 satellite scanned across AN Ursae Majoris, a star very similar to AM Herculis in its unusual optical properties. A soft (0.1-0.4 keV) X-ray flux averaging 2.8 x 10 to the -11th erg/sq cm-sec was detected from AN UMa, as had been anticipated by analogy with AM Her. Folding the X-ray flux measurement with the known binary period reveals an X-ray light curve with approximately 100% modulation, and thereby secures the identification of the X-ray source as AN UMa. Unlike the case in AM Her, the X-ray minimum in AN UMa occurs midway between optical linear-polarization peaks.

Hearn, D. R.↗

Characterization and Optimization of Skipper CCDs for the SOAR Integral Field Spectrograph

We present results from the characterization and optimization of Skipper charge-coupled devices (CCDs) for use in a focal plane prototype for the Southern Astrophysical Research Integral Field Spectrograph (SIFS). We tested eight Skipper CCDs and selected six for SIFS based on performance results. The Skipper CCDs are 6k × 1k, 15 μm pixels, thick, fully depleted, p-channel devices that have been thinned to ~250 μm, backside processed, and treated with an anti-reflective coating. We demonstrate a single-sample readout noise of <4.3 e - rms pixel -1 in all amplifiers. We optimize the readout sequence timing to achieve a readout noise of 0.5 e - rms pixel -1 after 74 non-destructive measurements, which can be accomplished in a region covering 5% of the detector area in a readout time of <4 minutes. We demonstrate single-photon-counting in all 24 amplifiers (four amplifiers per detector) with a readnoise of σ N ~ 0.18 e - rms pixel -1 after N samp = 400 samples, and we constrain the degree of nonlinearity to be ≲1% at low signal levels (0 e - to 50 e - ). Clock-induced charge (CIC) remains an important issue when the Skipper CCD is configured to provide a large full-well capacity. We achieve a CIC rate of <1.45 × 10 -3 e - pixel -1 frame -1 for a full-well capacity of ~900 e - , which increases to a CIC rate of ~3 e - pixel -1 frame -1 for full-well capacities ~40,000-65,000 e - . We also perform conventional CCD characterization measurements such as charge transfer inefficiency (3.44 × 10 -7 on average), dark current (~2 × 10 -4 e - pixel -1 s -1 ), photon transfer curves, cosmetic defects (<0.45% “bad” pixels), and charge diffusion (point-spread function < 7.5 μm) to verify that these properties are consistent with expectations from conventional p-channel CCDs used for astronomy. Furthermore, we provide the first measurements of the brighter-fatter effect and absolute quantum efficiency (≳80% between 450 and 980 nm; ≳90% between 600 and 900 nm) using Skipper CCDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Signatures of rotating black holes in quantum superposition

A new approach for operationally studying the effects of spacetime in quantum superpositions of semiclassical states has recently been proposed by some of the authors. This approach was applied to the case of a (2+1)-dimensional Bañados-Teitelboim-Zanelli (BTZ) black hole in a superposition of masses, where it was shown that a two-level system interacting with a quantum field residing in the spacetime exhibits resonant peaks in its response at certain values of the superposed masses. Here, we extend this analysis to a mass-superposed rotating BTZ black hole, considering the case where the two-level system corotates with the black hole in a superposition of trajectories. We find similar resonances in the detector response function at rational ratios of the superposed outer horizon radii, specifically in the case where the ratio of the inner and outer horizons is fixed. This suggests a connection with Bekenstein’s seminal conjecture concerning the discrete horizon spectra of black holes in quantum gravity, generalized to the case of rotating black holes. Here, our results further indicate that deeper insights into quantum-gravitational phenomena may be accessible via tools in relativistic quantum information and curved spacetime quantum field theory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Preliminary Experiences with the Rexon UL-320-FDR: An Automated Thermoluminescent Dosimeter Reader with Removable Contact Heating Planchets and an Infrared Temperature Feedback System

The Rexon UL-320 FDR is a novel resistive-heating thermoluminescent dosimeter reader with a unique temperature measurement system and an automated dosimeter processing mechanism. The removable contact heating planchets have black-body adhesives on the back for capturing temperature information with infrared sensors. A heating cycle feedback loop ensures accurate, precise, and reproducible heating sequences. Heating rates between 0.8 and 40°C s -1 for up to 1,000 s are possible. Photomultiplier tube sensitivity and drift, dark current counts, and planchet glow were measured experimentally. Additionally, 25 LiF:Mg,Ti dosimeters were calibrated to demonstrate reader performance. Sensitivity was optimized at 1,200 V, which produced the highest reference light count to dark current count ratio while extending photomultiplier tube life. Dark current counts measured with typical time-temperature profiles for LiF:Mg,Ti were below 10 counts per channel but increased by up to 2.5% for more extreme heating cycles. Reader sensitivity drifts of up to 10% were observed during extended automated operations with typical time-temperature profiles. Total counts resulting from planchet glow decreased with faster heating rates. Calibrations performed with LiF:Mg,Ti dosimeters yielded results comparable to more established reader designs. Spikes were observed in ~3% of the glow curves from planchet dust and oil burning off at elevated temperatures. The use of N 2 gas and sensitivity drift corrections are recommended to improve dosimetry performance for the UL-320 FDR reader.

61 RADIATION PROTECTION AND DOSIMETRY↗

Diurnal Lightning Distributions as Observed by the Optical Transient Detector (OTD) and the Lightning Imaging Sensor (LIS)

Data obtained from the OTD (April 1995 to March 2000) and LIS (December 1997 to December 2005) satellites (70 and 35 degree inclination low earth orbits, respectively) are used to statistically determine the number of flashes in the diurnal cycle both as a function of local and universal time. Also included are global flash density maps. The data is further subdivided by season, continental versus oceanic, night time versus day time, northern versus southern hemisphere, and other regions of interest such as the Brazilian rain forest and the Congo. The data includes corrections for detection efficiency and instrument view time. The data was compared with the "Carnegie Curve" and the diurnal global thunderstorm contributions from thunderday statistics fiom different continents as derived by Whipple and Scrase, 1936. Initial results indicate that the northern hemisphere fall (September to November) has a larger amplitude than the northern hemisphere spring (March to May). This may be due to the differences in the contribution of the Brazilian rain forest during these periods (the main lightning peak starts in September and ends in February with a secondary peak in April). For some areas of the world, the peak of the diurnal curve appears to be shifted to later in the evening.

Blakeslee, R. J.↗

Asteroid surface compositions from infrared spectroscopic observations - Results and prospects

Advances in IR detector technology, the increased availability of large aperture telescopes, and the techniques of Fourier transform spectroscopy now permit IR (with wavelengths greater than 1 micron) spectroscopic observations of asteroid surfaces. Asteroids already observed include Ceres, Vesta, and Eros. These initial results demonstrate that such studies can contribute new data concerning asteroid compositions. Some of the most diagnostic features of mineral spectra are in the IR spectral region, and for featureless spectra characterized only by slopes the extension of the spectral reflectivity curve into the IR provides tighter constraints on possible mineralogies. A systematic study of additional asteroids should exploit even further this new observational link to problems of meteorite origin and solar system evolution.

Larson, H. P.↗

β- and γ-Counting for Pre-detonation Nuclear Forensics on Eu-155

Post-detonation nuclear forensics was performed at Los Alamos National Laboratory (LANL) on 155Eu, a fission product on the wing of the fission product production curve whose yield is sensitive to fission fuel and neutron energy. With a half-life of 4.753 years, 155Eu provides a longer-lived option for these measurements than other fission products with similar mass numbers. The Chemistry Division Group - Nuclear and Radiochemistry, at LANL routinely measures a suite of fission products from 235U fissions in thermal neutron flux experiments known as thermal calibration exercises, using a mixture of gas proportional β-decay counting and γ-spectrometry on HPGe detectors. The fission products of interest are reported relative to a high-yield reference fission product from the same sample to create a running average ratio specific to neutron energy and fuel type; Equation 1 below shows the ratio-of-ratios R-value measured fission products are reported in: R i x = [A( i X)/A( 99 Mo)] unknown [A( i X)/A( 99 Mo)] 235 U n,th where A denotes activity, i X is the nuclide of interest, and 235 U n,th denotes irradiations of 235 U with thermal neutrons. Measurements of unknown fission spectra are ratioed to a running-average of thermal calibration results, and the resulting R-value can be referred to as against a library of irradiation conditions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Production of microchannel plates using nano-scale additive manufacturing

Microchannel plate (MCP) detectors have been the workhorse detector for many applications, including space borne ultra-violet imaging and spectrographic instruments. Recent advances in additive manufacturing (AM) have enabled fabrication of complex structures with nano-scale resolution facilitating the production of highly customizable MCPs. Using AM to produce MCPs potentially has many advantages over traditional fused glass substrates, including better material control (e.g., more robust glasses or ceramics), better control of microscopic features (e.g., unique pore geometries to improve performance), and better control of macroscopic features (e.g., printing precision curved surfaces for focal plane matching). Through a collaboration with industry, national laboratory, and university partners, small format microcapillary array substrates were produced using a standard polymer photoresin. In conclusion, these substrates were functionalized using atomic layer deposition and their performance was compared to current state-of-the-art Pb-glass and borosilicate-glass MCPs.

36 MATERIALS SCIENCE↗

Study of spectral/radiometric characteristics of the thematic mapper for land use applications

The previous characterization of scan-related low-frequency noise was confirmed and extended through analysis of reflective-band data from another nighttime acquisition. Amplitude and phase relationships of the level shifts were determined for each detector in each of free full frames. Analysis of scan-direction-related signal droop effects in nighttime data from the reflective bands was begun with encouraging initial observations. Also, an effort to characterize high-frequency noise in the reflective bands through Fourier analysis of nighttime data was initiated. Recommendations are made relative to the choice of radiometric calibration constants in the thematic mapper image processing system for the routine processing of TM data. Non-linear (piece-wise linear) calibration curves are recommended.

Malila, W. A.↗