Current Progress on the High-Field Cable Testing Facility at Fermilab

Fermi National Accelerator Laboratory (Fermilab) is constructing a new High Field Vertical Magnet Test Facility (HFVMTF) with capabilities comparable to the European facilities EDIPO and FRESCA2. The facility, located at Fermilab, will feature a background magnetic field of 15 T, generated by a magnet provided by Lawrence Berkeley National Laboratory (LBNL). The HFVMTF will support two U.S. national programs under the DOE Office of Science: the U.S. Fusion Energy Science (FES) program and the Magnet Development Program (MDP). It will enable the testing of HTS samples in high magnetic fields across a wide range of temperatures and facilitate the development of hybrid magnets combining LTS and HTS superconductors. This paper presents an overview of the current progress in constructing the facility, including updates on the test cryostat, power supplies, and systems for quench protection and monitoring.

Velev, G. [Fermilab]↗

Detection of high-frequency gravitational waves using SRF cavities

Today, apart from some isolated R\&D efforts, there are no GW experiments, yet which explore a large part of the vast frequency range above the LIGO/Virgo band. It is planned to establish an experiment at DESY and Fermilab to search for high-frequency GWs in the frequency range of 10\,kHz to 100\,MHz. The basic idea is to use superconducting radiofrequency (SRF) cavities to detect tiny harmonic deformations induced by GWs which change the boundary conditions of the oscillating electromagnetic field. This paper summarizes the challenging environmental boundary requirements, and the R\&D to operate a cavity using a LLRF system which pushes beyond state-of-the-art accuracy and resolutions and a seismic noise mitigated cryostat at 1.8\,K. The focus of this paper is the warm and cold commissioning of a prototype cavity, built 20 years ago during the MAGO collaboration, and its first measurement in our collaborative research project.

Giaccone, Bianca [Fermilab]↗

Experimental Investigation of Plasma Processing for PIP-II SSR2 Cavities

Field emission and multipacting are critical factors that limit the achievable operational gradient of superconducting radio frequency (SRF) cavities. Plasma processing (PP) has been demonstrated as an effective in-situ technique for mitigating hydrocarbon-induced field emission and multipacting across a range of cavity geometries. In this work, we present the initial development and subsequent application of plasma processing for PIP-II type II spoke resonators (SSR2). The process was carried out at room temperature on an SSR2 cavity equipped with the CM-style high-power coupler and installed in the cryostat. Cavity performance was evaluated through comparative cold tests conducted before and after plasma processing.

Giaccone, Bianca [Fermilab] (ORCID:000000027275846↗

Warm to cold correlations and other test results of the MQXFA Low-Beta Quadrupole magnets for the High-Luminosity Large Hadron Collider

The production of the MQXFA low-beta quadrupole magnets for the High Luminosity LHC (HL-LHC) is quite advanced with about 20 magnets cold tested in vertical cryostat. The MQXFA magnets are fabricated by the US HL-LHC Accelerator Upgrade Project (AUP) and are being used in the Q1 and Q3 Inner Triplet (IT) elements of the HL-LHC, whereas CERN is fabricating similar magnets for Q2a and Q2b IT elements. These large-aperture, high-gradient quadrupole magnets are first-of-the-kind accelerator magnets introducing Nb_3Sn conductor to High Energy Physics colliders. At this point of MQXFA production there is sufficient data to look at warm to cold correlations for the HL-LHC and for future use of Nb_3Sn magnets in particle accelerators. Examples of warm-cold correlations discussed in this paper are: field quality (including the use of magnetic shims for low-order harmonics correction), magnetic length, magnetic axis and magnetic field angle. A summary of main test data will also be presented and discussed.

Kurian, F. [Brookhaven]↗

Optimizing TinyTPC Test Stand for Low Energy Event Reconstruction

Introducing dopants into liquid argon offers a promising avenue to enhance the sensitivity and performance of LAr detectors such as DUNE. To explore this opportunity, we are optimizing and deploying the TinyTPC test stand, a compact time projection chamber with LArPix readout to study the effects of photosensitive dopants on the charge detected. TinyTPC enables comparative measurements of low-energy responses under various operational configurations and provides a platform to study the behavior of pixel readouts at low energy. We ensured system reliability through continuous current and voltage monitoring, modeling the detector's electrical behavior, and indirectly estimating total resistance under testing conditions. We ran the Blanche cryostat under various thresholds and gain configurations to evaluate their potential impact to low-energy event reconstruction and advancing R&D efforts for dopant integration in neutrino detectors

Van Loenen, Drew [Franciscan U. Steubenville]↗

Automating Testing of DUNE Electronics via a Finite State Machine

The Deep Underground Neutrino Experiment (DUNE) is a flagship international collaboration designed to study neutrinos tiny, nearly massless particles that may hold answers to fundamental questions about the Universe. Fermilab s Robotic Test Stand (RTS) plays a critical role in ensuring the quality of approximately 50,000 Application-Specific Integrated Circuit (ASIC) chips that will be used in DUNE s massive liquid argon detectors. These electronics will be inside the cryostat; therefore, they will need to have a high yield of working chips and low noise. To improve the automation and reliability of the RTS, this project focused on designing and implementing a Python-based finite state machine (FSM) to manage chip handling workflows. The FSM was developed as a modular software framework to coordinate robotic arm movements, manage chip tray positions, and monitor system states during testing. Key features include robust error handling routines, a pause/resume system for safe mid-cycle interruptions, and a simulation mode for iterative testing without hardware dependencies. The system was designed to prepare for seamless integration with RTS hardware components such as the robotic arm and vision system. This integration will streamline collaboration and enable efficient deployment of updates across the six total institutions performing testing. The outcomes of this internship contribute to Fermilab s mission to advance high-energy physics and support the DOE s national goals by directly improving the testing of equipment to be used in DUNE. The project also provided valuable experience in software design and contributing to the success of DUNE.

Kang, Caleb [William Rainey Harper Coll.]↗

Using Simulation to Interpret LArS's Results

Scintillation light analysis in liquid argon based neutrino detectors is restrained in capability due to uncertainty in fundamental constants critical to the analysis process. One such property is the Rayleigh scattering length of liquid argon. In the fall of 2023, the TallBo cryostat, located in the Noble Liquid Testing Facility (NLTF) at Fermilab, was used to study the scattering length of liquid argon in the Liquid Argon Scattering (LArS) experiment. Due to systematic errors unknown during measurement analysis, LArS s measurements were quite uncertain. By simulating the LArS experiment, we found that the downturn in detector count rate as a function of liquid argon height at low heights was caused by a misplaced silicon photo multiplier (SiPM). With concentrated effort, we may be able to successfully correct this effect by understanding the relationship between the specified Rayleigh scattering length and the measured attenuation length. With this information and further progression in analysis, we may be able to extract corrected measurements from the LArS data and attain a tangible experimental measurement of the scattering length of liquid argon.

Breaux, Auto D. [Tulane U.]↗

Studying MeV Scale Neutron Interactions in DUNE ND-LAr 2x2 Demonstrator

The Deep Underground Neutrino Experiment (DUNE) is a long-baseline neutrino oscillation experiment designed to make high-precision measurements of neutrino oscillation parameters and probe for new physics using a neutrino beam produced at Fermilab and measured at a near detector complex and a far detector located 1,300 km away at the Sanford Underground Research Facility. Precise neutrino energy reconstruction is essential for these measurements, with neutron production in neutrino–argon interactions representing a significant source of systematic uncertainty, as neutrons can carry away significant energy, making their detection and characterization crucial. DUNE’s near detector complex includes ND-LAr, a Liquid Argon Time Projection Chamber (LArTPC) detector designed to mirror the far detector technology and constrain neutrino–argon interaction systematics. The DUNE 2x2 Demonstrator, a pixelated LArTPC based on the ArgonCube design, serves as a prototype for ND-LAr. During 2x2 operations from October to November 2026, an Americium–Beryllium (AmBe) neutron source was deployed near the detector cryostat to obtain a high-statistics sample of neutron interactions. This poster presents progress in studying MeV-scale neutron interactions in this dataset by identifying de-excitation gammas from neutron capture on argon, providing a method for neutron identification and charge readout system calibration in future DUNE detectors.

Mao, Edgar [Syracuse U.] (ORCID:0009000600893306)↗

Design of a shipping fixture for a compact cryomodule hermetic assembly

Two conduction-cooled 915 MHz superconducting radio frequency hermetic assemblies must be safely transported from the Jefferson Lab in Newport News, VA to General Atomics in San Diego, CA for perfor-mance testing in a custom horizontal test cryostat. One hermetic assembly consists of a 2-cell 915 MHz cavity, a coaxial fundamental power coupler, and the warm-to-cold transition beam tubes. The second hermetic assembly consists of a 2-cell 915 MHz cavity only. The assemblies will be transported on a flatbed air-ride trailer over the approximate 4000 km distance. Design requirements included adequate attenuation of 4g vertical axis, 5g beamline axis, and 1.5g lateral axis shock events. The isolation system was designed using helical wire-rope isolators with modal and transient finite element analysis performed in Ansys. Results show shock attenuation of a 10 ms half-sine pulse input to < 1g in the vertical axis, < 1.5g in the beam-line axis, and < 0.5g in the lateral axis for both assem-blies at the specified design loads and all structural stresses are kept below the material yield limits. Addi-tionally, the natural frequencies of both isolation sys-tems adequately attenuate the fundamental modes of the critical structures.

Accelerator Physics↗

R$\&$D of Power Over Fiber in harsh environments and its novel application for the DUNE Photon Detection System

The Deep Underground Neutrino Experiment (DUNE) is a next generation long-baseline neutrino experiment that will send an intense beam of neutrinos through two detector complexes: a near detector complex located at Fermilab (Chicago), and a far detector complex located $\sim$ 1.5 km underground at Sanford Underground Research Facility (SURF) in South Dakota. One of the DUNE Far Detector (FD) modules will employ the Vertical Drift (VD) Technology, which will vertically drift the ionized electrons from the cathode plane suspended at the mid-height of the active volume of the cryostat. The Photon Detection System (PDS) will be installed along the cathode and behind the field cage to increase the photon detection coverage. Due to the high voltage ($\sim$300 kV) present at the cathode, conventional copper cables cannot be used to power the photon detectors. Therefore, Power-over-Fiber (PoF) technology will be deployed to power the PDS based on optical power transmission over optical fibers. This poster presents the R$&$D campaign on different PoF components under harsh environments and its novel application in the DUNE PDS.

Martinez caicedo, David Alejandro [South Dakota Sc↗

The Readout Electronics of the Mu2e Electromagnetic Calorimeter

The Mu2e electromagnetic calorimeter has been designed to measure ~100 MeV electrons with energy resolution σE/E <10%, time resolution σt < 500ps and position resolution σx < 1cm. The detector is composed of 1348 un-doped CsI crystals coupled to two large area Silicon Photomultipliers (SiPMs). Each SiPM is connected to a Front End Electronics (FEE) chip which hosts the shaping amplifier and the high voltage linear regulator. A group of 20 FEE is controlled by one Mezzanine Board (MB) which transmits the amplified signals to one Digitizer ReAdout Controller board (DiRAC). The DiRAC samples the waveforms at 200 MHz with 12-bit ADCs, packs the data according to the Mu2e custom format and transmits them to the event builder through an optical transceiver. To limit the number of pass-through connectors and the length of the cables, the readout and digitization electronics is located inside the detector cryostat and close to the interaction target. The boards will have to sustain a neutron fluence of about 5x10 10 n/cm 2 @ 1 MeVeq (Si)/y and a Total Ionizing Dose of about 12 krad, while working into a 1T magnetic field and a vacuum of 10 (-4) Torr. This harsh operational environment has made the electronics design challenging and required an extended campaign of tests to select and qualify the employed electronic components. In this paper we report on the board architecture and design, on the qualification of the prototypes, as well as on the results of the first vertical slice test of the Mu2e calorimeter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Construction, installation and operation of ProtoDUNE-SP

The single-phase liquid argon TPC at CERN (ProtoDUNE-SP) is an engineering prototype for the first module of the DUNE far detector. This prototype, which has dimensions of a cube of about 10 m edge, provides full validation of the use of the membrane tank technology for large dimension cryostats. Furthermore, the very high performance of the protoDUNE-SP TPC with more than 500 days of continuous and stable operation, demonstrated the reliability of the LAr detection technology at a scale never tested before. In this talk we will review the main characteristics and milestones of the construction and installation of protoDUNE-SP which provide a series of benchmarks for DUNE. The performance for several different detector working points will also be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A LArTPC with Vertical Drift for the DUNE Far Detector

The Far Detector of the Deep Underground Neutrino Experiment (DUNE) will be a large LArdetector located at a baseline of 1300 kilometers, 1.5 km deep underground. It is planned to bemade up of four modules, each with a total mass of 17 kt of LAr, at least the first two of which willconsist in Liquid Argon Time Projection Chambers (LArTPCs). To prove the feasibility of theLArTPC technology at the kiloton scale, the ProtoDUNE Single and Dual-Phase detectors wereconstructed and operated at the CERN Neutrino facility.This document describes the Vertical Drift detector concept, which is proposed to instrument thesecond DUNE module. It consists of a TPC where the electrons drift vertically, with a cathodesuspended at mid-height, towards anodes placed at the bottom and top of the detector. The anodeswould be made out of printed PCBs instead of wires, and the new disposition would allow the topreadout electronics to be accessible during the lifetime of the experiment. An enhanced photo-detection system is also proposed, with the photo-sensors placed on the cryostat walls and thecathode, but posing a challenge in terms of power and signal transmission. Studies are ongoingboth to overcome the technical challenges of this new design and to finalize the concept.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SAND - System for on-Axis Neutrino Detection - in the DUNE Near Detector Complex

The DUNE experiment aims to precisely measure the long baseline neutrino oscillation parameters. The DUNE Far Detector consists of four liquid argon time-projection chambers (total LAr mass of 17 kton for each cryostat), that will be installed at the Sanford Underground Research Facility (SURF) in South Dakota, 1300 km from the proton beam target. The Near Detector complex, located at Fermilab, is fundamental for limiting the systematic uncertainties, due to the neutrino/antineutrino flux and to the cross-section. It comprises three complementary detectors: ND-Lar, ND-Gar and SAND (System for on-Axis Neutrino Detection). ND-Lar and ND-Gar can move off-axis, while SAND is the only detector permanently on-axis, whose primary goal is to monitor the beam and to measure the flux. In this talk, the SAND design and the expected performances will be described together with its role within the Near Detector complex for the DUNE physics program.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Solid Polarized Target Development Facility at Jefferson Lab

Solid polarized targets are a crucial tool used in scattering experiments to investigate different properties of the nucleon. The equipment used to produce, measure, and maintain conditions for the polarized material is complex in comparison to nonpolarized targets. This, in combination with the frequency of polarized experiments run at Jefferson Lab, limits the opportunity to refine and build upon experience gained from previously constructed targets. To address this, the Jefferson Lab Target Group has begun the construction of a permanent facility dedicated to creating and testing material for Dynamic Nuclear Polarization. The design elements and manufacture of the test cryostat along with the incorporation of other DNP associated equipment will be presented.

Brock, James [Thomas Jefferson National Accelerato↗

Operational Experience of the NML Cryogenic Plant at the FAST Test Facility

The NML cryogenic plant cools two individually cryostated superconducting radio frequency (SRF) capture cavities and one prototype ILC cryomodule with eight SRF cavities. This complex accelerates electrons at 150 MeV for the Integrable Optics Test Accelerator (IOTA) ring, located at the Fermilab Accelerator Science and Technology (FAST) facility. The cryogenic plant is composed of two nitrogen precooled Tevatron satellite refrigerators, two Mycom 2016C compressors, a cryogenic distribution system, a Frick purifier compressor, two charcoal bed adsorber purifiers, and a liquid ring vacuum pump with a roots booster. The SRF cavities are immersed in a 2.0 K liquid helium bath, shielded with a 5 K gaseous helium shield and a liquid nitrogen cooled thermal shield. Since 2019, this R&D accelerator complex has gone through four science runs with an average duration of 12 months. Operational experience for each run, availability metrics, performance data and common outages are presented in this paper.

Wallace, Timothy [Fermilab] (ORCID:000900051589302↗

MicroBooNE BNB Inclusive Overlay Sample (With Wire Info)

MicroBooNE samples are provided for collaborative development in two different formats: HDF5, targeting the broadest audience, and artroot, targeting users that are familiar with the software infrastructure of Fermilab neutrino experiments and more in general of HEP experiments. The HDF5 files are stored on Zenodo, together with a list of artroot files accessible with xrootd.This sample includes simulated interactions of neutrinos from the Booster Neutrino Beam (BNB), overlaid on top of cosmic ray data. The sample is inclusive, i.e. it includes all types of neutrinos and interactions, with relative abundance matching our nominal flux and cross section models. Interactions are simulated in in the whole cryostat volume.The HDF5 files in this sample include the information at the wire waveform level (after deconvolution and finding of regions of interest). As this information significantly increases the file size, this sample contains about 17% of the events of the corresponding sample without wire information.More documentation, including detailed description of content, recipes, and example usage, at https://github.com/uboone/OpenSamples.Suggested text for acknowledgment is the following:We acknowledge the MicroBooNE Collaboration for making publicly available the data sets [data set DOIs] employed in this work. These data sets consist of simulated neutrino interactions from the Booster Neutrino Beamline overlaid on top of cosmic data collected with the MicroBooNE detector [2017 JINST 12 P02017].In addition, we request that software products resulting from the usage of the datasets are also made publicly available.

Abratenko, Polina↗

MicroBooNE BNB Inclusive Overlay Sample (No Wire Info)

MicroBooNE samples are provided for collaborative development in two different formats: HDF5, targeting the broadest audience, and artroot, targeting users that are familiar with the software infrastructure of Fermilab neutrino experiments and more in general of HEP experiments. The HDF5 files are stored on Zenodo, together with a list of artroot files accessible with xrootd.This sample includes simulated interactions of neutrinos from the Booster Neutrino Beam (BNB), overlaid on top of cosmic ray data. The sample is inclusive, i.e. it includes all types of neutrinos and interactions, with relative abundance matching our nominal flux and cross section models. Interactions are simulated in in the whole cryostat volume.The HDF5 files in this sample do not include the information at the wire waveform level ("NoWire" label), allowing for larger number of events to be included in the data set.More documentation, including detailed description of content, recipes, and example usage, at https://github.com/uboone/OpenSamples.Suggested text for acknowledgment is the following:We acknowledge the MicroBooNE Collaboration for making publicly available the data sets [data set DOIs] employed in this work. These data sets consist of simulated neutrino interactions from the Booster Neutrino Beamline overlaid on top of cosmic data collected with the MicroBooNE detector [2017 JINST 12 P02017].In addition, we request that software products resulting from the usage of the datasets are also made publicly available.