Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Critical Experiment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Investigating Similarity Differences for Light-water-Moderated and Polyethylene-Moderated Systems

Oak Ridge National Laboratory has performed validation studies in support of Pacific Northwest National Laboratory’s analysis of the Sum-of-Fractions method. Work in a companion paper examines the validation methods and results for various mixtures of fissile isotopes in various concentrations moderated and reflected by water and polyethylene. Those results indicate a greater coverage of critical experiments for validating water moderated and reflected systems versus those moderated and reflected with polyethylene.

07 ISOTOPE AND RADIATION SOURCES↗

Delayed Critical and Subcritical Experiments with Polyethylene Moderated Unreflected Thin 15 in. Diameter HEU Metal Plates

The thin ~15 in. diameter highly enriched uranium (HEU) metal plates were assembled to delayed criticality at the Oak Ridge Critical Experiments Facility (ORCEF) in 1969 with various thicknesses of polyethylene (varying from 1/16 to 2$\frac{3}{8}$ inches) between uranium metal plates. The average 235 U enrichment was 93.27 wt. %. These unreflected critical configurations contained 4$\frac{2}{3}$ to 20$\frac{5}{6}$ thin 15 in. diameter HEU metal plates (on loan from Los Alamos National Laboratory [LANL] and shipped to Oak Ridge National Laboratory [ORNL] on June 3, 1969). Depending on the thickness of polyethylene, the enriched uranium masses varying from 28,053 to 135,148 grams. Fractional plate sections consisted of the appropriate number of 60° pie sections. In addition to the measurement at delayed criticality, subcritical measurements were also performed by the inverse kinetic rod drop method. Prompt neutron decay constant measurements were also performed by the Rossi alpha and randomly pulsed neutron method using a time-tagged spontaneous fission californium neutron source; these are briefly reported here. At the time of these measurements in 1969, the thin HEU metal plates were in near-pristine condition with extremely little oxidation, allowing better descriptions of the uranium plates than the use of these plates in a heavily oxidized and deteriorated condition in recent reflected benchmark experiments at the LANL facility at the Nevada Test Site with these same thin highly enriched uranium metal plates. This report documents the experimental information for the measurements performed so that later researchers can perform the required uncertainty and calculational analyses and documentation to use these data for an International Nuclear Criticality Safety Benchmark Evaluation Program (ICSBEP) or a Nuclear Energy Agency (NEA) benchmark. Data from the experiments described should be acceptable for use as criticality safety benchmark experiments for the ICSBEP and the NEA nuclear criticality safety benchmark program once the uncertainty analysis on the measured neutron multiplication factors is completed. Additional data—such as the dimensional inspection reports, uranium isotopic information, and other relevant particulars—should be retrieved from the Y-12 Plant or LANL and incorporated in the final ICSBEP benchmark. Based on previous ICSBEP benchmarks with this enriched uranium metal at ORCEF, the uncertainties in $k_{eff}$ could be as low as ± 0.0002 for some configurations. Other experiments with smaller-diameter than 15 in. diameter HEU metal plates have been benchmarked in HEU-METFAST-001. The prompt neutron time decay measurements could be the basis for an International Reactor Physics Benchmark Program. Preparation of the present report is part of an effort at ORNL to document more than 15 undocumented critical and subcritical experiments enumerated in ORNL/TM-2019/18 and performed by ORNL at ORCEF and other US Department of Energy critical experiments facilities using more than 500 operational days of critical facility time. This work for this report publication was supported by the Nuclear Criticality, Radiation Transport and Safety NCSP Program at ORNL.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

NCERC 2024 Highlights

The National Nuclear Security Administration (NNSA) is entrusted with ensuring the safety, security, and reliability of the nation’s nuclear weapons stockpile while advancing programs aimed at reducing global nuclear proliferation. These critical mission objectives are achieved through the expertise of a highly skilled team of professionals. The operations at the National Criticality Experiments Research Center (NCERC) play a vital role in developing and enhancing knowledge and expertise in advanced nuclear technologies. NCERC supports a wide range of mission areas, including nuclear criticality safety, nuclear emergency response, and nuclear nonproliferation, safeguards, and arms control. It also provides support to the Department of Homeland Security, advances stockpile stewardship science, and delivers scientific expertise to other government agencies, such as NASA and the Defense Threat Reduction Agency. NCERC conducts experiments utilizing diverse nuclear materials, from small neutron-emitting sources for testing radiation detection equipment to larger quantities of uranium and plutonium for criticality experiments. A cornerstone of NCERC's mission portfolio includes the operation of four critical mass assembly machines—Planet, Comet, Flattop, and Godiva-IV—which are instrumental in advancing nuclear science and ensuring the nation’s nuclear security objectives.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quantifying Burst Repeatability for Godiva IV

The minimum resolvable relative change in the neutron source emission of Godiva IV between bursts, i.e., burst repeatability, was quantified using a combination of activation monitors and a resistance temperature detector (RTD). Measurements support changes in the neutron source emission between bursts can be determined with a precision of 2.7%. The measurements were performed during a series of twelve Godiva IV bursts and were a collaborative effort between Los Alamos National Laboratory, Sandia National Laboratories, and Pacific Northwest National Laboratory. Gold, iron, nickel, and sulfur activation monitors were positioned in a sample holder in the central cavity of Godiva IV for each burst. The RTD is part of the Godiva burst diagnostic system and is in a fixed location in the safety block of Godiva IV. It is used to determine the temperature rise of the burst, i.e., the difference between the maximum temperature recorded during the burst and the initial temperature prior to the burst. Differences in either the specific activity of the activation monitor reactions, or the temperature rise can be used to determine the relative change in the neutron source emission for separate bursts, but historic results have proven that each method is susceptible to various sources of biases which generally cannot be isolated using a single method. We address this issue by applying both measurement methods and analyzing the correlation between them. The results presented in this work will be used to support future experiments with Godiva IV at the National Criticality Experiments Research Center (NCERC).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Completion of IER 305: Molybdenum Sleeve Experiments and Preparations for Performing IER 441: Epithermal Tantalum Experiments [Slides]

This presentation includes a look into Sandia critical experiments including the 7uPCX, BUCCX, and assembly design. This presentation touches on the completion of IER 305 with CED-3b, CED-4a, and CED-4b. Finally, there are preparations to perform IER 441 including new hardware, critical configurations, and next steps.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Rossi-α Measurements on a System Consisting of Weapons Grade Plutonium Moderated by Polyethylene

A critical experiment was performed on the Planet assembly to provide nuclear data in a thermal neutron spectrum, in particular to provide experimental data to help validate thermal scattering laws for polyethylene. The fuel consisted of layers of weapons grade plutonium plates that were moderated and reflected by various thicknesses of high density polyethylene. Rossi-α measurements were performed on a slightly modified configuration from the configuration used for the critical measurements. The Rossi-α measurement techniques are discussed and results are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Proposed Methodology for Evaluating and Validating TSLs [Slides]

This presentation begins by providing an overview of the research and discusses recent efforts in validating thermal neutron scattering cross sections, including differential cross section measurements at ORNL for evaluation and validation, total cross section measurements at RPI, pulsed-neutron die-away experiments at LLNL, and integral criticality experiments by LLNL. The presentation also proposes a methodology not only for validating thermal scattering files that utilizes all available experimental data, but also for evaluating new libraries as demonstrated on polystyrene. In conclusion, polystyrene evaluation was conducted using multiple experiments, including differential and integral. The proposed methodology has been shown to improve neutron transport and files have been submitted to NNDC for inclusion in ENDF/B-VIII.1 release. MCT-012 & PCM-002 has been relatively insensitive to changes in $\mathcal{S}(α,β)$. The research found that differences in differential results don’t always propagate to differences in integral results, hence why evaluation of differential data important. Future work on the project is also discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigation of Benchmark $k$ eff Sensitivity and Uncertainty for 239 Pu fission in Specific Energy Ranges

Nuclear data at intermediate energies (from 1 to 100s of keV) are evaluated based on scarce differential data and theory unable to capture physics’ expected structure. There is also a lack of integral data. This is a known deficiency and is challenging to address. Calculated effective multiplication factor, k eff , values for intermediate energy experiments are ~25× further from experiment than for fast energies and are often well outside the experimental uncertainties. The goal of the PARADIGM (PARallel Approach of Differential and InteGral Measurements) project is to significantly re duce the uncertainties of intermediate energy nuclear data for 239 Pu. To this end, PARADIGM simultaneously optimizes experiments at both the Los Alamos Neutron Science Center (LANSCE) and National Criticality Experiments Research Center (NCERC). The combined set of data will inform new intermediate-energy nuclear data. By execution of differential and integral experiments, establishment of new theory, and undertaking nuclear data evaluation in parallel, the timeline to deliver improved nuclear data to users will be reduced significantly that is to three years. For the PARADIGM project, it was decided to optimize an integral experiment for two neutron energy ranges, within the full intermediate energy range. The low energy range goes from 1 to 30 keV, while the higher energy range goes from 30 to 600 keV. This work focuses on nuclear data sensitivities and uncertainties for 239 Pu fission for existing experiments in the International Criticality Safety Benchmark Evaluation Project (ICSBEP). When designing new experiments, it is important to understand what benchmarks currently exist. For a more traditional experiment design (in which a specific application model(s) exists), comparisons would be made between the application model(s) and existing benchmarks. For PARADIGM, there is no specific application model, but instead the specific nuclear data reaction and energy ranges of interest can be explored for existing benchmarks.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dual particle imaging: Applications in security and environmental imaging

Radiation imaging detectors have been applied in a variety of fields for detection, localization and characterization of radioactive sources. In this work, we describe a handheld detection system (H2DPI) that can simultaneously image neutrons and gamma rays, and reconstruct the energy spectra of the incident particles. This system was applied to the detection and characterization of a plutonium metal source in experiments performed at the National Criticality Experiments Research Center, where the 4.5 kg plutonium source was placed approximately 60 cm from the H2DPI. Neutron and gamma-ray images were measured that show good agreement with the known location of the source. Furthermore, the H2DPI was also used to measure the neutron spectrum, which shows the expected shape of a Watt fission spectrum, and the gamma-ray energy spectrum, which shows the energies common to plutonium metal. Finally, we describe the application of the H2DPI in augmented reality, whereby real-time neutron and gamma-ray imaging data can be streamed to the Microsoft HoloLens to allow the user to visualize the source locations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detecting and characterizing special nuclear material for nuclear nonproliferation applications

Abstract There is an urgent need for new, better instrumentation and techniques for detecting and characterizing special nuclear material (SNM), i.e., highly enriched uranium and plutonium. The development of improved instruments and techniques requires experiments performed with the SNM itself, which is of limited availability. This paper describes the findings of experiments performed at the National Criticality Experiments Research Center conducted using new instruments and techniques on unclassified, kg-quantity SNM objects. These experiments, performed in the framework of the Department of Energy, National Nuclear Security Administration Consortium for Monitoring, Technology, and Verification, focused on detecting, characterizing, and localizing SNM samples with masses ranging from 3.3 to 13.8 kg, including plutonium and highly enriched uranium using prototype detectors and techniques. The work demonstrates SNM detection and characterization using recently-developed prototype detection systems. Specifically, we present new results in passive detection and imaging of plutonium and uranium objects using gamma-ray and dual particle (fast neutron and gamma-ray) imaging. We also present a new analysis of the delayed neutron emissions during active interrogation of uranium using a neutron generator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pitch Variation Experiments in Water-Moderated Square-Pitched U(6.90)O 2 Fuel Rod Lattices with Fuel to Water Volume Ratios Spanning 0.08 to 0.67

The twenty-seven critical experiments in this series were performed in 2020 in the SCX at the Sandia Pulsed Reactor Facility. The experiments are grouped by fuel rod pitch. Case 1 is a base case with a pitch of 0.8001 cm and no water holes in the array. Cases 2 through 6 have the same pitch as Case 1 but contain various configurations with water holes, providing slight variations in the fuel-to-water ratio. Similarly, Case 7 is a base case with a pitch of 0.854964 cm and no water holes in the array. Cases 8 through 11 have the same pitch as Case 7 but contain various configurations with water holes. Cases 12 through 15 have a pitch of 1.131512 cm and differ according to the number of water holes in the array, with Case 12 having no water holes. Cases 16 through 19 have a pitch of 1.209102 cm and differ according to number of water holes in the array, with Case 16 having no water holes. Cases 20 through 23 have a pitch of 1.6002 cm and differ according to number of water holes in the array, with Case 20 having no water holes. Cases 24 through 27 have a pitch of 1.709928 cm and differ according to number of water holes in the array, with Case 24 having no water holes. As the experiment case number increases, the fuel-to-water volume ratio decreases.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Zeno: Critical Fluid Light Scattering Experiment

The Zeno (Critical Fluid Light Scattering) experiment is the culmination of a long history of critical fluid light scattering in liquid-vapor systems. The major limitation to making accurate measurements closer to the critical point was the density stratification which occurs in these extremely compressible fluids. Zeno was to determine the critical density fluctuation decay rates at a pair of supplementary angles in the temperature range 100 mK to 100 (mu)K from T(sub c) in a sample of xenon accurately loaded to the critical density. This paper gives some highlights from operating the instrument on two flights March, 1994 on STS-62 and February, 1996 on STS-75. More detail of the experiment Science Requirements, the personnel, apparatus, and results are displayed on the Web homepage at http://www.zeno.umd.edu.

Gammon, Robert W.↗

Update on the Benchmark Analysis of the Jupiter Experiments: Plutonium Moderated by Lead

The Jupiter experiment was a series of measurements in the summer of 2017 to analyze the effects of voids in lead moderated plutonium assemblies. This experiment was part of a larger campaign that took place at the National Criticality Experiments Research Center (NCERC) in collaboration with the Japan Atomic Energy Agency (JAEA) that also investigated assemblies with differing uranium enrichments. The purpose for this campaign was to provide data useful for a potential lead-bismuth cooled accelerator driven system. This data is needed due to the low number of benchmarks involving lead. Given the wide use of lead for shielding in addition to new reactor designs, there is a need for further benchmarking that this experiment could help fulfill. In addition, adding more benchmarks to the International Criticality Safety Benchmark Evaluation Project (ICSBEP) is helpful for further validation of simulation methods used for criticality safety. This summary is an update on the current progress of this analysis, and all results shown are preliminary.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Subcritical Assembly for Training and Education Use at the Oak Ridge National Laboratory

A near-final design has been completed for a new subcritical assembly at Oak Ridge National Laboratory (ORNL). This subcritical assembly will support the Nuclear Criticality Safety Program (NCSP) training and education program to augment current subcritical assembly capabilities at Sandia National Laboratories (SNL) and at the National Criticality Experiments Research Center (NCERC). Other collaborations have been proposed with the Sunrise Consortium and others. This proposed subcritical assembly uses legacy AGN-201M research reactor fuel plates that are available from the Y-12 National Security Complex. This subcritical assembly contains approximately 620 grams of 235 U as UO 2 particulates distributed homogeneously in radiation-stabilized polyethylene. The fuel plates will have a graphite neutron reflector to obtain a core multiplication, M, from 10 to 50, corresponding to a k eff of 0.9 to 0.95, respectively. The subcritical assembly will be able to support at least four experiments for the training courses: (1) the addition of fissile material to increase neutron multiplication (mass), (2) a core separation experiment (interaction), (3) the effect of adding moderators to the core (moderation), and (4) the effect of adding neutron absorbers to the core (poison/absorption). The proposed ORNL subcritical assembly will provide additional student bandwidth to support NCSP training courses and to provide for some backup capacity if nuclear facility operations are disrupted at SNL or NCERC due to some unforeseen issue. The subcritical assembly will be designed to be an inherently safe subcritical assembly—subcritical under all normal and abnormal conditions—and it will provide the capability to conduct hands-on training to support NCSP and general nuclear criticality safety (NCS) staff training and qualification goals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Subcritical Assembly for Training and Education Use at the Oak Ridge National Laboratory [Abstract]

A near-final design has been completed for a new subcritical assembly at Oak Ridge National Laboratory (ORNL). This subcritical assembly will support the Nuclear Criticality Safety Program (NCSP) training and education program to augment current subcritical assembly capabilities at Sandia National Laboratories (SNL) and at the National Criticality Experiments Research Center (NCERC). Other collaborations have been proposed with the Sunrise Consortium and others. This proposed subcritical assembly uses legacy AGN-201M research reactor fuel plates that are available from the Y-12 National Security Complex. This subcritical assembly contains approximately 620 grams of 235 U as UO 2 particulates distributed homogeneously in radiation-stabilized polyethylene. The fuel plates will have a graphite neutron reflector to obtain a core multiplication, M, from 10 to 50, corresponding to a k eff of 0.9 to 0.95, respectively. The subcritical assembly will be able to support at least four experiments for the training courses: (1) the addition of fissile material to increase neutron multiplication (mass), (2) a core separation experiment (interaction), (3) the effect of adding moderators to the core (moderation), and (4) the effect of adding neutron absorbers to the core (poison/absorption). The proposed ORNL subcritical assembly will provide additional student bandwidth to support NCSP training courses and to provide for some backup capacity if nuclear facility operations are disrupted at SNL or NCERC due to some unforeseen issue. The subcritical assembly will be designed to be an inherently safe subcritical assembly—subcritical under all normal and abnormal conditions—and it will provide the capability to conduct hands-on training to support NCSP and general nuclear criticality safety (NCS) staff training and qualification goals.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Integral Experiments Request 441 CED-3b Summary Report

Under IER-441, critical experiments were done with and without tantalum test rods within a central test region surrounded by 7uPCX fuel rods. The experiments were done in new critical assembly hardware designed to support the 7uPCX fuel in a 1.02 cm triangular-pitched array. Appendix I is a draft of section 1 of the ICSBEP benchmark evaluation of the experiments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗