Skylab program payload integration. Skylab film environmental effects

The effects of the Skylab environments on the 22 types of film used for data recording on Skylab were evaluated. Environmental histories and sensitometric curves for 114 rolls of film used for this evaluation are presented. Photographic parameters evaluated in detail were film fogging of black and white films, changes in maximum density of color film, latent image fading, and changes in film sensitivity. Other photographic and film physical anomalies such as electrostatic exposure, emulsion cracking, and reciprocity failure were also documented. Results based upon comparison of film sensitometric data for flight film with ground control film and ground test film are presented independently for each film type. The study showed that photographic film fulfilled the requirements of the Skylab applications in which it was used. Environmental film degradation, although present on almost every roll, did not preclude recording sufficient data to meet experiment requirements for all film, except film type SC-5. Specific conclusions are provided in the areas of further analyses, tests, and developments.

Source record↗

Insulating Cryogenic Pipes With Frost

Crystallized water vapor fills voids in pipe insulation. Small, carefully controlled amount of water vapor introduced into dry nitrogen gas before it enters aft fuselage. Vapor freezes on pipes, filling cracks in insulation. Ice prevents gaseous nitrogen from condensing on pipes and dripping on structure, in addition to helping to insulate all parts. Industrial applications include large refrigeration plants or facilities that use cryogenic liquids.

Stephenson, J. G.↗

Effect of Crystal Orientation on Fatigue Failure of Single Crystal Nickel Base Turbine Blade Superalloys

High Cycle Fatigue (HCF) induced failures in aircraft gas-turbine engines is a pervasive problem affecting a wide range of components and materials. HCF is currently the primary cause of component failures in gas turbine aircraft engines. Turbine blades in high performance aircraft and rocket engines are increasingly being made of single crystal nickel superalloys. Single-crystal Nickel-base superalloys were developed to provide superior creep, stress rupture, melt resistance and thermomechanical fatigue capabilities over polycrystalline alloys previously used in the production of turbine blades and vanes. Currently the most widely used single crystal turbine blade superalloys are PWA 1480/1493 and PWA 1484. These alloys play an important role in commercial, military and space propulsion systems. PWA1493, identical to PWA1480, but with tighter chemical constituent control, is used in the NASA SSME (Space Shuttle Main Engine) alternate turbopump, a liquid hydrogen fueled rocket engine. Objectives for this paper are motivated by the need for developing failure criteria and fatigue life evaluation procedures for high temperature single crystal components, using available fatigue data and finite element modeling of turbine blades. Using the FE (finite element) stress analysis results and the fatigue life relations developed, the effect of variation of primary and secondary crystal orientations on life is determined, at critical blade locations. The most advantageous crystal orientation for a given blade design is determined. Results presented demonstrates that control of secondary and primary crystallographic orientation has the potential to optimize blade design by increasing its resistance to fatigue crack growth without adding additional weight or cost.

Arakere, Nagaraj K.↗

Stress Corrosion Evaluation of Nitinol 60 for the International Space Station Water Recycling System

A stress corrosion cracking (SCC) evaluation of Nitinol 60 was performed because this alloy is considered a candidate bearing material for the Environmental Control and Life Support System (ECLSS), specifically in the Urine Processing Assembly of the International Space Station. An SCC evaluation that preceded this one during the 2013-2014 timeframe included various alloys: Inconel 625, Hastelloy C-276, titanium (Ti) commercially pure (CP), Ti 6Al-4V, extra-low interstitial (ELI) Ti 6Al-4V, and Cronidur 30. In that evaluation, most specimens were exposed for a year. The results of that evaluation were published in NASA/TM-2015-218206, entitled "Stress Corrosion Evaluation of Various Metallic Materials for the International Space Station Water Recycling System,"1 available at the NASA Scientific and Technical Information program web page: http://www.sti.nasa.gov. Nitinol 60 was added to the test program in 2014.

Torres, P. D.↗

An Engineering Approach to Analyze Damage Initiation Modes in Tapered Composite Structures

In this work an engineering approach is demonstrated for analyzing damage initiation modes in tapered composite structures. The analysis methodology includes simulation of the non-linear static response of tapered composite structures under static tension loads to predict the location of interfacial delamination initiation. Furthermore, the developed methodology provides a strength-based criterion to assess whether damage initiation will occur in the inter-laminar delamination or intra-laminar matrix cracking mode. Based on the results of the analysis, a tapered composite structure is fabricated and tested under displacement-controlled quasi-static tension loading. The damage initiation location captured experimentally is compared with the analysis towards achieving preliminary qualitative validation. The linear stiffness of the tapered composite structure is predicted within 15% of the experimental average thereby achieving preliminary quantitative validation.

Rao, Prabhakar M.↗

An Engineering Approach to Analyze Damage Initiation Modes in Tapered Composite Structures

In this work an engineering approach is demonstrated for analyzing damage initiation modes in tapered composite structures. The analysis methodology includes simulation of the non-linear static response of tapered composite structures under static tension loads to predict the location of interfacial delamination initiation. Furthermore, the developed methodology provides a strength-based criterion to assess whether damage initiation will occur in the inter-laminar delamination or intra-laminar matrix cracking mode. Based on the results of the analysis, a tapered composite structure is fabricated and tested under displacement-controlled quasi-static tension loading. The damage initiation location captured experimentally is compared with the analysis towards achieving preliminary qualitative validation. The linear stiffness of the tapered composite structure is predicted within 15% of the experimental average thereby achieving preliminary quantitative validation.

Prabhakar M Rao↗

Effectiveness of Shot Peening In Suppressing Fatigue Cracking At Non-Metallic Inclusions In Udimet(Registered Trademark)720

The fatigue lives of modern powder metallurgy disk alloys can be reduced over an order of magnitude by cracking at inherent non-metallic inclusions. The objective of this work was to study the effectiveness of shot peening in suppressing LCF crack initiation and growth at surface nonmetallic inclusions. Inclusions were carefully introduced at elevated levels during powder metallurgy processing of the nickel-base disk superalloy Udimet 720. Multiple strain-controlled fatigue tests were then performed on machined specimens with and without shot peened test sections at 427 C and 650 C. The low cycle fatigue lives and failure initiation sites varied as functions of inclusion content, shot peening, and fatigue conditions. A large majority of the failures in as-machined specimens with the introduced inclusions occurred at cracks initiating from inclusions intersecting the specimen surface. These inclusions reduced fatigue life by up to 100X, when compared to lives of material without inclusions residing at specimen surface. Large inclusions produced the greatest reductions in life for tests at low strain ranges and high strain ratios. Shot peening improved life in many cases by reducing the most severe effects of inclusions.

Barrie, Robert L.↗

Effectiveness of Shot Peening in Suppressing Fatigue Cracking at Non-Metallic Inclusions in Udimet(trademark) 720

The fatigue lives of modern powder metallurgy disk alloys can be reduced by over an order of magnitude by surface cracking at inherent non-metallic inclusions. The objective of this work was to study the effectiveness of shot peening in suppressing LCF crack initiation and growth at surface nonmetallic inclusions. Inclusions were carefully introduced at elevated levels during powder metallurgy processing of the nickel-base disk superalloy Udimet 720. Multiple strain-controlled fatigue tests were then performed on machined specimens at 427 and 650 C in peened and unpeened conditions. Analyses were performed to compare the low cycle fatigue lives and failure initiation sites as a function of inclusion content, shot peening, and fatigue conditions. A large majority of the failures in as-machined specimens with introduced inclusions occurred at cracks initiating from inclusions intersecting the specimen surface. The inclusions could reduce fatigue life by up to 100X. Large inclusions had the greatest effect on life in tests at low strain ranges and high strain ratios. Shot peening can be used to improve life in these conditions by reducing the most severe effects of inclusions.

Barrie, Robert L.↗

Proof test criteria for thin walled pressure vessels

A proof test criterion for assuring minimum service life requirements for aerospace pressure vessels is provided. The criteria proposed are based on the results of several experimental programs conducted on surface flaw specimens fabricated from 2219 aluminum base and weld metal. A description is presented of the stable crack growth behavior of surface flaws during loading. Conclusions derived from an experimental program are discussed. It is found that significant stable crack growth under increasing load can occur prior to failure. However, significant variability in results can be anticipated even when carefully controlled laboratory procedures are employed.

Finger, R. W.↗

Power module control moment gyro

The directed design modifications to the Skylab/ATM CMG for application to the Power Module include new rotors of a different material with high resistance to stress corrosion cracking. The spin bearing retainer fix which was determined during the post Skylab mission was incorporated, and the speed pickoff was improved through the use of pickoff thermal cycling screening tests. The unlimited gimbal freedom on box axes was incorporated using slip ring assemblies. The on-orbit replacement capability was also incorporated for the CMG assembly and the inverter assembly.

Source record↗

Deformation and failure of transversely loaded composite plates

Quasi-isotropic graphite/epoxy clamped circular plates were loaded under control point loading. Deflections and strains at various locations were monitored up to failure. Various damage mechanisms, such as intralaminar matrix cracking, delaminations and fiber breaks, are correlated with the strain records. The damage at various stages of deformation was characterized by means of X-radiography. Results are compared with an approximate isotropic plate theory.

Daniel, I. M.↗

Deployment, Foam Rigidization, and Structural Characterization of Inflatable Thin-Film Booms

Detailed investigation of the construction, packaging/deployment, foam rigidization, and structural characterization of polyimide film inflatable booms is described. These structures have considerable potential for use in space with solar concentrators, solar sails, space power systems including solar arrays, and other future missions. Numerous thin-film booms or struts were successfully constructed, inflated, injected with foam, and rigidized. Both solid-section and annular test articles were fabricated, using Kapton polyimide film, various adhesives, Styrofoam end plugs, and polyurethane pressurized foam. Numerous inflation/deployment experiments were conducted and compared to computer simulations using the MSC/DYTRAN code. Finite element models were developed for several foam-rigidized struts and compared to model test results. Several problems encountered in the construction, deployment, and foam injection/rigidization process are described. Areas of difficulty included inadequate adhesive strength, cracking of the film arid leakage, excessive bending of the structure during deployment, problems with foam distribution and curing properties, and control of foam leakage following injection into the structure. Many of these problems were overcome in the course of the research.

Schnell, Andrew R.↗

Vibration-based health characterization of multiple IMUs in UAV applications

Inertial measurement units (IMUs) are vital in UAV navigation for vehicle attitude and position estimation, especially in the frequently-occurring case of temporary loss of GPS capabilities. Degradation in these units could yield inaccurate position estimates, resulting in incorrect input for vehicle control systems. A wide variety of these units exist to meet the needs of UAV operators, general aviation, and military vehicles. In recent decades, lightweight and inexpensive MEMS sensors have grown in popularity with respect to UAVs. Studies into the failure modes of MEMS devices suggest that vibration is one of the leading causes of MEMS degradation. MEMS sensors are generally encased in their own hermetic packaging, as their small size and sensitivity cause them to be particularly vulnerable to air damping and particulate contamination when exposed. Exposure to excessive vibration can cause cracking in this packaging as well as damage to connecting electronics, with recorded results that cause sensors to act outside of their specifications, potentially providing unreliable input to controllers. A prior study from the Politecnico di Torino looked into the degradation of MEMS IMUs, specifically the AXIS-AIS402, for aerospace and vibrating environments. In the study, the authors found that after exposing MEMS IMUs to simulated vibrations from working conditions of aerospace applications, the sensors showed increased noise and increased bias instability. At NASA Ames, several widely-used MEMS IMUs were selected for a new IMU degradation study, comparing accelerometer performance before and after exposure to similar levels of vibration simulating aerospace conditions. The IMUs were selected from the Pixhawk autopilot systems, hobby sUAS, or prior experimental studies at NASA. Additionally, the industrial grade VectorNav-100 IMU was selected as a ground truth reference point to which the performance of the test sensors can be compared. In the study, each sensor is exposed to functional levels of UAV vibration as replicated on a single-frequency vibratory table in the NASA Ames SHARP Laboratory, and each accelerometer is characterized for bias, drift, and noise characteristics both before and after vibratory exposure. The focus of this study is to monitor the health of the IMU sensors and determine if sensor degradation can be detected from output error and frequency spectrum analysis, rather than from microscopic examination of the sensors. In this case, sensor degradation and faulty data can be more easily detectable by non-experts hoping to use these sensors as an important piece of an integrated package. In addition, specific sensor degradation modes potentially leading to in-flight hazards could be identified, such as accelerated levels of drift and altered temperature response. The overall goal of this work is to increase levels of safety for future users of these sensors and to provide a clear analysis of sensor limitations currently lacking in most sensor specification documentation.

IMUs↗

Fundamental investigation of stress corrosion cracking

Two principle areas studied were stress corrosion crack growth rates of a titanium alloy in liquid environments containing halide ions and pitting corrosion of titanium in bromide solutions. Two initial assumptions were made, that the rate of propagation was controlled by a macroscopic solution parameter and that this parameter was viscosity. A series of solutions were prepared using lithium chloride as the solute and water, methanol, glycerin, formic acid, acetone, dimethyl sulphoxide, etc. As solvents, these solutions were prepared with a 5:1 solvent-solute ratio. Viscosity was varied by changing the temperature and it was found: (1) In all solvents the velocity of cracking was proportional to the reciprocal of the viscosity. (2) Each solvent gave a separate relationship, (3) The temperature dependence and numerical values for the apparent activation energy of cracking and viscosity were the same.

Beck, T. R.↗

Creep of plasma sprayed zirconia

Specimens of plasma-sprayed zirconia thermal barrier coatings with three different porosities and different initial particle sizes were deformed in compression at initial loads of 1000, 2000, and 3500 psi and temperatures of 1100 C, 1250 C, and 1400 C. The coatings were stabilized with lime, magnesia, and two different concentrations of yttria. Creep began as soon as the load was applied and continued at a constantly decreasing rate until the load was removed. Temperature and stabilization had a pronounced effect on creep rate. The creep rate for 20% Y2O3-80% ZrO2 was 1/3 to 1/2 that of 8% Y2O3-92% ZrO2. Both magnesia and calcia stabilized ZrO2 crept at a rate 5 to 10 times that of the 20% Y2O3 material. A near proportionality between creep rate and applied stress was observed. The rate controlling process appeared to be thermally activated, with an activation energy of approximately 100 cal/gm mole K. Creep deformation was due to cracking and particle sliding.

Firestone, R. F.↗

Defect sensitivity of filament-wound structures in compression

Compression testing of 12-ply graphite/bismaleimide laminated plates with induced and natural defects is discussed, and emphasis is placed on resultant changes in strength and stiffness. Ply drops, ply cuts, and fiber crossovers are studied by comparison with a quasi-isotropic control group. It is observed that, as expected, failure initiates at the defects and progresses via delamination, sublaminate buckling, angle-ply cracking, and longitudinal ply failure. The ultimate stress is reduced by approximately 40 percent for all types of defects except the unsymmetrical cut-ply specimens which averages a 54-percent reduction. The average stiffness reduction of 10 percent is observed for specimens with induced defects. Fiber crossovers are found to reduce the laminate strength and stiffness significantly.

Jensen, David W.↗

Insights Developed Into the Damage Mechanism of Teflon FEP Thermal Control Material on the Hubble Space Telescope

Metalized Teflon FEP (DuPont; fluorinated ethylene propylene) thermal control material on the Hubble Space Telescope (HST) has been found to degrade in the space environment. Teflon FEP thermal control blankets retrieved during the first servicing mission were found to be embrittled on solar-facing surfaces and to contain microscopic cracks (the FEP surface is exposed to the space environment). During the second servicing mission, astronauts noticed that the FEP outer layer of the multilayer insulation blanketing covering the telescope was cracked in many locations. Large cracks were observed on the light shield, forward shell, and equipment bays. A tightly curled piece of cracked FEP from the light shield was retrieved during the second mission. This piece was severely embrittled, as witnessed by ground testing. A Failure Review Board was organized by NASA Goddard Space Flight Center to determine the mechanism causing the multilayer insulation degradation. This board included members of the Electro-Physics Branch of the NASA Glenn Research Center at Lewis Field. Density measurements of the retrieved materials obtained under the review board's investigations indicated that FEP from the first servicing mission was essentially unchanged from pristine FEP but that the second servicing mission FEP had increased in density in comparison to pristine FEP (ref. 1). The results were consistent with crystallinity measurements taken using x-ray diffraction and with results from solid-state nuclear magnetic resonance tests (see the table and ref. 1). Because the second servicing mission FEP was embrittled and its density and crystallinity had increased in comparison to pristine FEP, board researchers expected that the first servicing mission FEP, which was also embrittled, would also have increased in crystallinity and density, but it did not. Because the retrieved second servicing mission material curled while in space, it experienced a higher temperature extreme during thermal cycling (estimated at 200 C) than the first servicing mission material (estimated at 50 C). Therefore, Glenn initiated and conducted an investigation of the effects of heating pristine FEP and FEP that had been exposed on the Hubble Space Telescope. Samples of pristine and first and second servicing mission FEP were heated to 200 C and evaluated for changes in density and morphology. We hoped that the results would help explain why FEP degrades in the Hubble Space Telescope space environment.

deGroh, Kim K.↗