Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Control Samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Taste Perception of Branched Maltooligosaccharides

Oral processing of starch generates linear and branched maltooligosaccharides (MOS). This study investigates the impact of branching and the degree of polymerization (DP) on MOS taste detection. Three branched MOS samples (A−C) were enzymatically prepared from gelatinized waxy corn starch and characterized using reducing-end assays, MALDI-TOF MS, β-amylase hydrolysis, and GC-MS linkage analysis. Samples A, B, and C had average DPs of 6, 10, and 18, respectively, with α-1,6 branch points comprising 9−13% of glycosidic bonds; linear MOS were negligible. In triangle tests, participants evaluated MOS samples and a maltose control at 75 mM, with and without lactisole, a sweet receptor inhibitor. All samples were detectable without lactisole (d′ = 1.81−2.9; p < 0.05), but not with lactisole (d′ = 0−0.61; p > 0.05). These findings demonstrate that α-1,6 branching enables MOS detection via the sweet receptor, not the putative “starchy” receptor, underscoring the importance of glycosidic structure in carbohydrate taste perception.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tailoring the rheological properties of high protein suspension by thermal-mechanical treatment

The viscoelasticity of concentrated protein suspensions associates closely with the mixing efficiency and cleaning frequency of facility during high-protein food development. This study investigated the effects of thermal-mechanical treatment on the viscoelasticity of milk protein isolate (MPI) suspensions and their underlying mechanisms to develop protein ingredient with low viscoelasticity. MPI suspensions (20%) were treated at 25, 50 and 85°C for 10-60 min under constant shear (100 s -1 ), followed by storage at 4°C. The viscosity (η) of MPI suspension treated at 50°C and 85°C was similar to 1-10% as those treated at 25 ° C. After four days of storage at 4°C, η showed the least value in 50°C-treated samples compared to those at 25 ° C and 85 ° C. The η and storage modulus (G') was decreased with prolonged treatment at 25 and 50°C, whereas opposite trend was found in 85°C treated samples. Differential scanning calorimetry found proteins in 50°C treated samples had smaller enthalpy than those in the control and 25°C treated samples. Protein surface hydrophobicity was increased slightly from 25°C to 50°C, but remarkably in 85°C treated samples. Ultra-small angle x-ray scattering showed the radius of gyration (R-g) of casein micelle was similar to 38 nm at 25°C and 50°C treated samples but increased to similar to 44 nm 85°C treated samples with reduced compactness. A new sphere-like structure with R-g of 18 nm was generated in 85°C treated samples. These findings suggested modulating temperature during thermal-mechanical treatment is essential to alter protein structures and morphology for desirable rheological properties.

59 BASIC BIOLOGICAL SCIENCES↗

Silicon Dioxide Deposited Using Atmospheric Pressure Plasma Chemical Vapor Deposition for Improved Adhesion and Water Intrusion Resistance for Lightweight Manufacturing

This work aims to demonstrate the barrier coating, and adhesion promoting properties of silica-based coatings deposited using an atmospheric pressure plasma torch (APPT). This is achieved by applying an industrial grade adhesive to silica thin films deposited, on the surfaces to be joined, using atmospheric pressure plasma chemical vapor deposition (APP-CVD), to make single joint lap shear samples of different metal combinations commonly found in lightweight manufacturing such as aluminum and magnesium as well as steel. To deposit these thin films, two separate silicon based organic precursors, hexamethyldisiloxane (HMDSO), and tetraehylorthosilicate (TEOS), are used. Here, samples are bonded using DuPont Betamate 1486 adhesive, and the lap shear results for these films are compared to the lap shear results of a chemically cleaned control using the same adhesive. The APPT uses a microwave power supply and gas mixtures of N 2 and Ar. The adhesion of the films are tested using lap shear, and elevated temperature water soaks are conducted on the joints as well to simulate environmental exposure. Lap shear results from samples with silica thin films max shear stress are 25%-115% increase compared to control samples depending on material. After exposure to water soak the max shear strength of the joints decreased by less than 15%, which demonstrates the films capabilities as a water barrier. Film morphology is examined using Scanning Electron Microscopy (SEM), and the film’s composition and approximate thickness are obtained using Rutherford Backscattering Spectroscopy (RBS).

36 MATERIALS SCIENCE↗

3rd harmonic magnetometry assessment of NbTiN-based SIS structures

In the quest for alternative superconducting materials to bring accelerator cavity performance beyond the bulk niobium (Nb) intrinsic limits, a promising concept proposes that superconductor-insulator-superconductor (SIS) thin film structures can delay magnetic flux penetration in accelerator cavities to higher fields [1]. NbTiN is a candidate superconductor for such structures. We have demonstrated high quality NbTiN and AlN deposited by reactive direct current magnetron sputtering (DCMS), both for individual layers and multilayers. Interface quality has been assessed for bi-layer stacks with various NbTiN and AlN thicknesses from 500 and 30 nm down to 3 and 1 nm. These SIS structures show continued sharp interfaces. The Hfp enhancement of the films was examined with 3rd harmonic magnetometry. The system was designed and built in an ongoing collaboration with CEA Saclay. It can measure 1? to 2? samples on a temperature controlled stage. This contribution presents the assessment of the first penetration field enhancement with 3rd harmonic magnetometry for standalone films and multilayer nanostructures.

Valente, Anne-Marie↗

Perspective: Biochemical and Physical Constraints Associated With Preparing Thin Specimens for Single-Particle Cryo-EM

While many aspects of single-particle electron cryo-microscopy (cryo-EM) of biological macromolecules have reached a sophisticated level of development, this is not yet the case when it comes to preparing thin samples on specimen grids. As a result, there currently is considerable interest in achieving better control of both the sample thickness and the amount of area that is useful, but this is only one aspect in which improvement is needed. This Perspective addresses the further need to prevent the macromolecular particles from making contact with the air-water interface, something that can result in preferential orientation and even structural disruption of macromolecular particles. This unwanted contact can occur either as the result of free diffusion of particles during the interval between application, thinning and vitrification of the remaining buffer, or—when particles have been immobilized—by the film of buffer becoming too thin prior to vitrification. An opportunity now exists to apply theoretical and practical insights from the fields of thin-film physical chemistry and interfacial science, in an effort to bring cryo-EM sample preparation to a level of sophistication that is comparable to that of current data collection and analysis.

59 BASIC BIOLOGICAL SCIENCES↗

New Projections for Dark Matter Searches with Paleo-Detectors

Paleo-detectors are a proposed experimental technique to search for dark matter (DM). In lieu of the conventional approach of operating a tonne-scale real-time detector to search for DM-induced nuclear recoils, paleo-detectors take advantage of small samples of naturally occurring rocks on Earth that have been deep underground (≳5 km), accumulating nuclear damage tracks from recoiling nuclei for O(1)Gyr. Modern microscopy techniques promise the capability to read out nuclear damage tracks with nanometer resolution in macroscopic samples. Thanks to their O(1)Gyr integration times, paleo-detectors could constitute nuclear recoil detectors with keV recoil energy thresholds and 100 kilotonne-yr exposures. This combination would allow paleo-detectors to probe DM-nucleon cross sections orders of magnitude below existing upper limits from conventional direct detection experiments. In this article, we use improved background modeling and a new spectral analysis technique to update the sensitivity forecast for paleo-detectors. We demonstrate the robustness of the sensitivity forecast to the (lack of) ancillary measurements of the age of the samples and the parameters controlling the backgrounds, systematic mismodeling of the spectral shape of the backgrounds, and the radiopurity of the mineral samples. Specifically, we demonstrate that even if the uranium concentration in paleo-detector samples is 10−8 (per weight), many orders of magnitude larger than what we expect in the most radiopure samples obtained from ultra basic rock or marine evaporite deposits, paleo-detectors could still probe DM-nucleon cross sections below current limits. For DM masses ≲ 10 GeV/c2, the sensitivity of paleo-detectors could still reach down all the way to the conventional neutrino floor in a Xe-based direct detection experiment.

Baum, Sebastian (ORCID:0000000167929381)↗

Toward the validation of crowdsourced experiments for lightness perception

Crowdsource platforms have been used to study a range of perceptual stimuli such as the graphical perception of scatterplots and various aspects of human color perception. Given the lack of control over a crowdsourced participant’s experimental setup, there are valid concerns on the use of crowdsourcing for color studies as the perception of the stimuli is highly dependent on the stimulus presentation. Here, we propose that the error due to a crowdsourced experimental design can be effectively averaged out because the crowdsourced experiment can be accommodated by the Thurstonian model as the convolution of two normal distributions, one that is perceptual in nature and one that captures the error due to variability in stimulus presentation. Based on this, we provide a mathematical estimate for the sample size needed to produce a crowdsourced experiment with the same power as the corresponding in-person study. We tested this claim by replicating a large-scale, crowdsourced study of human lightness perception with a diverse sample with a highly controlled, in-person study with a sample taken from psychology undergraduates. Our claim was supported by the replication of the results from the latter. These findings suggest that, with sufficient sample size, color vision studies may be completed online, giving access to a larger and more representative sample. With this framework at hand, experimentalists have the validation that choosing either many online participants or few in person participants will not sacrifice the impact of their results.

97 MATHEMATICS AND COMPUTING↗

Benchmarking of X‐Ray Fluorescence Microscopy with Ion Beam Implanted Samples Showing Detection Sensitivity of Hundreds of Atoms

Abstract Single impurities in insulators are now often used for quantum sensors and single photon sources, while nanoscale semiconductor doping features are being constructed for electrical contacts in quantum technology devices, implying that new methods for sensitive, non‐destructive imaging of single‐ or few‐atom structures are needed. X‐ray fluorescence (XRF) can provide nanoscale imaging with chemical specificity, and features comprising as few as 100 000 atoms have been detected without any need for specialized or destructive sample preparation. Presently, the ultimate limits of sensitivity of XRF are unknown – here, gallium dopants in silicon are investigated using a high brilliance, synchrotron source collimated to a small spot. It is demonstrated that with a single‐pixel integration time of 1 s, the sensitivity is sufficient to identify a single isolated feature of only 3000 Ga impurities (a mass of just 350 zg). With increased integration (25 s), 650 impurities can be detected. The results are quantified using a calibration sample consisting of precisely controlled numbers of implanted atoms in nanometer‐sized structures. The results show that such features can now be mapped quantitatively when calibration samples are used, and suggest that, in the near future, planned upgrades to XRF facilities might achieve single‐atom sensitivity.

36 MATERIALS SCIENCE↗

Compilation of a Solar Mirror Materials Database and an Analysis of Natural and Accelerated Mirror Exposure and Degradation

The National Renewable Energy Laboratory (NREL) has been conducting exposure experiments on solar reflectors for over four decades. Thousands of mirror samples from over one hundred suppliers have been exposed to and monitored in a range of relevant environments. These test conditions include outdoor test settings and several controlled laboratory environments. These samples have been rigorously individually characterized using a series of reflectance measurements, visual inspections, and in some cases, in-depth composition analysis to identify degradation modes, reflectance losses, and other mirror properties integral to understanding the solar reflector's life cycle. Here, this paper compiles the decades of measurement data into a concise statistical analysis. It includes exposure and degradation data for numerous reflector types, including secondary-surface reflector permutations of polymer and glass superstrates with silver and aluminum reflectors as well as front-surface reflectors. The results herein are intended to analyze environmental stressors and degradation trends among various historical and state-of-the-art solar reflectors. It may be used to support solar reflector design, effective testing methodology, and inform manufacturing decisions moving forward. Presented are the results of the compiled database and an initial analysis for degradation rate modeling using full-spectrum and wavelength-dependent approaches. The database is a growing resource hosted on a live, publicly accessible website. In conjunction with the analysis presented here, it provides a valuable resource to the solar reflector manufacturing and testing industry.

14 SOLAR ENERGY↗

Modernizing the Legacy Fission Wire Measurement System for the Advanced Test Reactor-Critical Facility

Operational lifetime extensions of existing research reactors have emphasized the need for refurbishment, replacements, and upgrades to supporting equipment and instrumentation. The Advanced Test Reactor (ATR) at Idaho National Laboratory (INL), which entered service in 1967, has recently completed the sixth core internals change-out and has scheduled operations until at least 2040. Reactor maintenance and operational risk management is critically important in the research reactor community, however supporting measurement systems sometimes get overlooked when maintenance is planned. The Fission Wire Measurement System (FWMS) is a custom measurement system designed in the 1960s to measure the beta-particle activity of irradiated uranium-aluminum fission wires. This measurement is conducted to determine the fission rate profile of the Advanced Reactor Test Critical (ATR-C) facility. The ATR-C is an open-pool, low-power test reactor that was purpose driven to resemble ATR and is used to qualify experiment configurations and verify core models prior to full-power experiment irradiations in ATR. A power distribution measurement in ATR-C uses uranium-aluminum wires that are distributed throughout the ATR-C core to validate simulation and modeling results. These measurements require 340 to 1500 wires to be irradiated and measured within a 12-hour window. The activity of the wires is measured in the required time with the FWMS, which was put into service in 1965 at the Radiation Measurements Laboratory (RML). The system consists of 4 measurement channels and one reference channel, each with a 2-pi proportional gas flow detector and the measurement channels each have an automated sample changer. This legacy system is crucial to the continued operations of ATR and has undergone some minor hardware upgrades since 1965, however the system presently relies on custom control boards, custom gas ion chambers, analog amplifiers/discriminators, and a user interface (UI) for the system written in outdated code. Much of the equipment and software is custom with no commercial replacements or support and limited documentation. The existing control software requires an operating system that is no longer supported, creating more vulnerabilities to continued operations. A project is underway with a third-party vendor to design, build, and document a new control and data acquisition system (CDAS) for the FWMS. The new upgrade will replace the control system, computer, UI, sample changer motors, and main power supply while maintaining the interface with existing detector hardware. The upgraded system will be operated in parallel with the current hardware and software to conduct validation testing. This equipment upgrade demonstrates the commitment at ATR to ensuring successful operations and potential future research reactors at INL.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Design improvements for a recirculating reactor: Enhanced temperature measurement and sample-isolated reactivity in steady-state kinetic studies

Building upon a previous recirculating reactor design [S.A. Tenney, K. Xie, J.R. Monnier, A. Rodriguez, R.P. Galhenage, S. Audrey, D.A. Chen, Rev. Sci. Instrum. 84, 104101 (2013)], we present significant improvements that address key limitations in steady-state kinetic measurements for heterogeneous catalysis. The enhanced reactor design features direct sample heating with a focused IR lamp and temperature measurement in direct contact with the sample, enabling more accurate temperature control and improved kinetic analysis. A critical advancement is the isolation of sample reactivity from reactor wall contributions, ensuring that only the sample contributes to measured reaction rates. This was a limitation in earlier designs where the entire reactor contributed to the observed reactivity. The system incorporates a bypass flow cell for direct comparison with powder catalysts under identical conditions using a standard plug-flow reactor configuration. We demonstrate these capabilities through CO oxidation experiments on Pt(111) single crystals and graphene-passivated Pt(111), highlighting the system's ability to differentiate catalytic activity in model systems and directly compare them with high surface area powder catalysts. This reactor is particularly suited for thin films and low surface area catalysts that are not effectively evaluated in traditional flow reactors, especially for samples with low numbers of active sites or slow reaction rates.

36 MATERIALS SCIENCE↗

Progress Report on Graphite-Salt Interaction Studies (FY21)

This report summarizes the activities performed in FY21 to investigate the interactions between nuclear graphite and molten salts, such as FLiNaK. First, building on last year’s achievements, the team improved the procedure for measurements on pressurized salt intrusion in nuclear graphite and performed new experiments at variable pressures with specimens of different sizes and shapes. Additionally, the team actively provided suggestions and comments for ASTM D8091, Standard Guide for Impregnation of Graphite with Molten Salts , which came up for periodic revision in 2021. Second, the team expanded its capabilities to further characterize salt-impregnated graphite by procuring and installing a laser-induced breakdown spectroscopy (LIBS) instrument capable of producing a 3D chemical composition of a surface and subsurface region of specimens. A methodology for accurately analyzing information was developed, and a manuscript was submitted for publication. The LIBS instrument sample cell is sealed in controlled inert atmosphere, which is an advantage for using humidity-sensitive samples and Be-contaminated samples. This aligns with the team’s effort to expand the capabilities of handling FLiBe and Becontaining materials in two newly installed glovebox units. Third, the team performed preliminary tribology tests for pebble graphite wear in contact with stainless steel in dry state and in molten salt at high temperature. These tests are needed to establish the baseline for the wear of pebble graphite by friction against metallic walls. The friction and wear of pebbles in the fluoride salt-cooled hightemperature reactor are expected to generate dust, which is a concern for other components’ properties and safe reactor operation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Method Validation Summary for L16.2 AD-ISO-0015 for ISO-17025 / NFAC Applications

Methods for the analysis of semi-volatile organic compounds are employed at Savannah River National Laboratory (SRNL) for routine and non-routine samples from tank waste, process control, waste acceptance, and a wide array of other process and research samples. A method has been developed by SRNL, based on existing methods for semi-volatile analysis, for the analysis of nitroaromatic high explosives by gas chromatography / mass spectrometry in soils and sediments. Relative to past work performed at SRNL on nitroaromatic explosives, this developed, optimized, and validated method can achieve lower limits of detection and quantitation, greater precision, lower bias, higher linearity, and accuracy across a greater linear range.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Method and apparatus for in situ synthesis of SiC, SiC ceramic matrix composites, and SiC metal matrix composites during additive manufacturing

Methods and apparatuses for in situ synthesis of SiC, CMCs, and MMCs are disclosed, comprising: providing an apparatus having: an electromagnetic energy source; an autofocusing scanner; a powder system for SiC and one or more powders; a powder delivery system; a shielding gas comprising argon and/or nitrogen; and a computer coupled to and configured to control the energy source, scanner, powder system, and powder delivery system to deposit layers of the sample; programming the computer with specifications of the sample; using the computer to control electromagnetic radiation, mixing ratio, and powder deposition parameters based on the specifications of the sample; and using the autofocusing scanner to focus and scan the electromagnetic radiation onto the sample while the powders are concurrently deposited by the powder delivery system onto the sample to create a melting pool to deposit one or more layers onto the sample. Other embodiments are described and claimed.

Liu, Jian↗

Videos, photos, and AI-derived grain size data associated with “High-throughput AI Video Surveys Enable Reproducible Multiscale Sediment Size Mapping, with Implications for Hydrobiogeochemical Parameterization”

NOTE: The manuscript associated with this data package is currently in review. The data may be revised based on reviewer feedback. Upon manuscript acceptance, this data package will be updated with the final dataset and additional metadata. This data package is associated with the manuscript “High-throughput AI Video Surveys Enable Reproducible Multiscale Sediment Size Mapping, with Implications for Hydrobiogeochemical Parameterization” under review. This data package includes five data types: 1) raw photos and videos from drone survey and walking smartphone surveys; 2) images derived from raw videos; 3) manual labeling of reference scales; 4) metadata for all images and photo resolution derived from artificial intelligence (AI) models or manual labels, 5) grain size data obtained from AI models for all photos, 6) metadata and grain size data after quality control, 7) summaries of sample efficiency for all data, and 8) computational fluid dynamics (CFD) data used to support hydro-biogeochemical (HBGC) parameter estimation. Such data is used to 1) demonstrate significant improvements in accuracy, efficiency, and quality control for grain size data collection with the help of AI models, 2) study the spatial heterogeneity of grain size and observation reproducibility based on tens of thousands of data points generated by the AI models, and 3) evaluate the impacts of grain size heterogeneity on key HBGC parameters across sediment-to-reach and hourly-to-yearly scales. In particular, the data package contains 116 folders and 179696 files. The files include 41 videos in .mov format, 64047 photos in .jpg format, 13541 video-derived photos in .png format, 12747 segmentation mask data in .tif format, 12747 segmentation data in .json format, 24771 .csv files that with metadata and grain size for each individual photo as well as water depth and velocity data from CFD and observation, 51791 .txt files of raw AI predicted labels, and 11 flight record data in .srt format. The summary for all metadata and grain size statistics information is included in “Scales_V3_NG.csv” and “Statistics_V3_NG.csv”. The summary for data that pass data quality control (QC) level 0-2 is included in “QCStatistics_V3_NG.csv”. The QC level 0 represents photos whose photo resolution is positive, excluding photos that miss reference scale. The QC level 1 means reference scale circularity uncertainty is less than 5% for smartphone images while representing photo resolution is larger than 0.44 mm/pixel for drone images. The QC level 2 means excluding photos whose grain number is less than 100, a minimum number of grains recommended by classic literature. The summary for each video’s name, length, frame rates, survey area, grain number, survey efficiency, etc. can be found in “QCSummary_V3_NG.csv”. The summary for site name, GPS coordinates, and number of images at each site can be found in “SitesSummary_V3_*.csv” files. Overall computational efficiency summary is reported in Table 4 of accompanying manuscript. Additionally, the nitrate concentration data used in this work was downloaded from an existing dataset published on ESS-DIVE (Boat-Dragged Sensor Hanford Reach.csv; Conner A. et al., 2020). We thank the United States Forest Service, Washington Department of Fish and Wildlife, Washington Department of Natural Resources, Cowiche Canyon Conservatory, Port of Benton, and the Confederated Tribes and Bands of the Yakama Nation for access to field locations where the data were collected. We also thank the Yakama Nation Tribal Council and Yakama Nation Fisheries for working with us to facilitate data collection and optimization of data usage according to their values and worldview.

54 ENVIRONMENTAL SCIENCES↗

Learning Stochastic Parametric Differentiable Predictive Control Policies

We present a scalable unsupervised learning-based method for obtaining explicit control policies for model predictive control problems for stochastic linear systems with additive uncertainties subject to nonlinear chance constraints. We call the proposed method stochastic parametric differentiable predictive control (SP-DPC), which extends the recently proposed deterministic DPC policy optimization algorithm. We formulate the SP-DPC as a deterministic approximation to the stochastic parametric constrained optimal control problem via independent sampling of the problem's parameters and uncertainties. This formulation allows us to directly compute the policy gradients via automatic differentiation of the problem's value function, evaluated over sampled parameters and uncertainties. In particular, the computed expectation of the problem's value function is backpropagated through the finite-time closed-loop system rollouts parametrized by a known nominal system dynamics model and neural control policy. We also provide theoretical probabilistic guarantees on closed-loop stability and chance constraints satisfaction for systems controlled by learned neural policies. We demonstrate the computational efficiency and scalability of the proposed policy optimization algorithm in three numerical examples, including systems with a large number of states or subject to nonlinear constraints.

Drgona, Jan↗