Laboratory Evaluation of Commercial Utility Microgrid Controller Test Results

The functional requirements of many microgrid controllers (MGCs) are expanding and evolving to meet growing utility and community needs. At a high level, the utility microgrid controller serves resilience and reliability use cases by coordinating transitions between grid-connected and islanded states and by managing the system during island operations. This includes control scenarios that require the microgrid controller to use flexible microgrid boundaries, maintain energy balance, coordinate with peer systems, and manage grid-forming (GFM) and grid-following (GFL) distributed energy resources (DER). In order to evaluate these functional enhancements, microgrid controller test plans must also be developed to ensure that the implemented controllers provide adequate performance. This report provides MGC test plans for both island operation and transition functions. The functions covered in this report include feeder level energy management, island constraint management, secondary voltage and frequency control, black start, and synchronized reconnection. This second edition update also includes results from applying the tests to a commercial utility microgrid controller. These results evaluate the performance and reliability of the controller under various operational scenarios. It identifies specific areas where the controller excels and highlights gaps that need to be addressed for future enhancements. The application of these test plans on real-world system behavior provides insights on commercial equipment readiness for field deployment. These test cases can be applied to utility-managed microgrid controllers that exclusively manage utility-owned equipment; the tests also apply to third-party managed microgrid controllers that coordinate with utility- and customer-owned equipment. The report can also be used by technology developers and project developers in industry to evaluate control strategies and performance characteristics for community microgrid controllers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Commercialization of the Transportation-Security, Tracking, and Reporting System (T-STAR)

The Transportation-Security, Tracking, and Reporting System (T-STAR) was developed by the National Nuclear Security Administration, NA-21, Office of Radiological Security (ORS) to provide a transportation security system for detection and tracking during transport of Category 1 and Category 2 radiological material. Few off-the-shelf systems for conveyance tracking offer detection of a cargo compartment breach or a removal of the cargo. Systems that do offer this capability often require permanent installation through modifying of the conveyance itself. This is not sustainable in many countries where ORS is building use, storage, and transport security capacity. The development of T-STAR has moved from fielding robust prototypes deployed in countries ranging from North America, Latin America and Central Asia to a commercially produced product that can now be deployed to provide enhanced security during transit. Each prototype deployment resulted in important lessons learned, which informed the requirements for the final commercial product. T-STAR uses both cellular and Iridium satellite modems to provide redundant communications to provide the configuration, status, and alerts to a server monitoring the shipment, which is accessible using a multilanguage browser-based user interface. A wireless security system employing using Z-wave sensors for intrusion detection located in the conveyance provide low cost but effective solution for a wide range of conveyance types. Additional capabilities include the ability to monitor a vehicles’ CANBUS (Controller Area Network) system, an ethernet port for high throughput sensor information such as video cameras, and the ability to power and use advanced external sensor payloads. These features make the T-STAR a capable and expandable security gateway that can be deployed on a variety of conveyances from box trucks to open trailers. The ability to provide tracking, monitoring, and detection provide a key component in overall best practices designed to protect shipments of radioactive material.

Schultze, Michael [ORNL] (ORCID:0000000283205671)↗

Case Study: The Tower Companies' Commercial Office Solar PV

This case study describes how the Tower Companies selected and successfully executed onsite solar photovoltaic installations at its commercial office properties and highlights the resulting increase in asset value.

solar, solar PV, photovoltaic, onsite solar, comme↗

Bay Area Regional Energy: Network Integrated Commercial Retrofits (BRICR) Project. Final Report

The BRICR project applied large-scale building energy modeling concepts with the aim of reducing the cost of energy efficiency targeting, design, and project development, and measurement of energy savings for energy efficiency programs implemented by local governments that serve small and medium commercial buildings (SMB). The project leveraged the services and resources of existing local government energy programs serving disadvantaged and hard-to-reach SMB customers. In contrast to programs run by utilities, local government programs generally do not have direct access to energy billing records for an entire class of customers in a geographic area, which prior research demonstrated useful for large-scale building energy model baseline development and calibration. , However, local governments are rich in public records that offer important clues about physical attributes and uses that, along with behavior, determine energy use. Relying only on public records, BRICR demonstrated development of credible baseline energy models for 3,792 office, retail, and hotel buildings. Publicly disclosed annual energy use data from a local energy benchmarking program and anonymized data from the Building Performance Database, the nation’s largest dataset about energy-related characteristics of buildings, were utilized to validate and calibrate energy models via an innovative method comparing distributions of energy intensity by fuel type for portfolios of buildings of similar size, vintage, and use. Portfolio calibration does not provide certainty that an energy model fits an individual building; the method is useful when billing data is not accessible – a common situation for researchers, energy service providers and ESCOs, local governments, and any party other than a utility. A software component was developed, the BRICR gem, which automates simulation when relevant data is added or edited by the user to a file saved in the standardized BuildingSync XML schema for energy audit data. The component was demonstrated as a simplified means to generate a mass of energy models corresponding to public records containing basic attributes such as building scale, location, use, year built, and aspect ratio in combination with building energy code prototype data corresponding to use and vintage. The component was also demonstrated as a simplified means to automate energy simulation when attributes are revised; the intention was to enable iterative improvement of the baseline model and energy savings estimates for common energy conservation measures as users revise relevant attributes based on their observations. In the context of institutional change and uncertainty for the participating local government energy programs, 13 whole building retrofits were completed. Impacts were measured by applying the CalTRACK2.0 methods to standardize measurement of normalized metered energy consumption. The GRIDMeter methods of stratified sampling and individual load shape analysis were applied to adjust for impacts of the effect of COVID-19 on retrofitted buildings in the context of all local buildings of similar size and use. Excluding impacts of the pandemic, retrofitted buildings demonstrated between 1.6% and 25.1% reduction in energy use. The project contributed use cases and feedback that helped inform evolution of the software tools and data formats that were combined for the first time in the BRICR project.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Data Centers in the Commercial Sector

This fact sheet summarizes some of the key needs, barriers, and opportunities related to data center management and operations in the Commercial Sector.

data center, data center management, commercial bu↗

Commercial PACE Financing for New Construction

This fact sheet provides an overview for building owners and developers to take advantage of commercial property assessed clean energy (CPACE) financing for new construction, adaptive reuse, or renovation projects.

Commercial PACE, CPACE, Microgrid, Renewables, new↗

Thermal Energy Storage in Commercial Buildings

Space heating and cooling account for as much as 40% of energy used in commercial buildings. Aligning this energy consumption with renewable energy generation through practical and viable energy storage solutions will be pivotal in achieving 100% clean energy by 2050. Integrated on-site renewable energy sources and thermal energy storage systems can provide a significant reduction of carbon emissions and operational costs for the building owner.

buildings energy storage↗

Energy Technology Commercialization and Entrepreneurship: Insights From the U.S. Department of Energy's Office of Technology Transitions 2024 Energy Technology University Prize Faculty Track

The Energy Technology University Prize (EnergyTech UP) was established in 2022 with the goal of challenging student teams to develop impactful business plans for energy technologies of their choosing. EnergyTech UP is part of the The American Made Challenges program portfolio, funded by the U.S. Department of Energy. EnergyTech UP is specifically funded by the Department of Energy's Office of Technology Transfer (OTT) and is administrated by staff at the National Renewable Energy Laboratory (NREL). Since its inception, the annual prize has attracted applications from approximately 1,948 students across nearly every U.S. state and territory, awarding over $1 million in funds to student teams. In 2024, the prize expanded to include a Faculty Track, which invited faculty members from degree-granting institutions across the U.S. to design entrepreneurship-based curricula or educational activities. This new track aims to foster innovation in energy entrepreneurship education by leveraging the expertise of faculty to create robust, practical, and inclusive learning experiences. This report summarizes the themes, strategies and impacts identified in proposals from EnergyTech UP's inaugural Faculty Track. Our primary data for organizing insights are the Faculty Track applications themselves. This evaluation of 2024 EnergyTech UP Faculty Track applications aims to support future EnergyTech UP Faculty Track applicants as well as others who are interested in promoting, developing, and/or implementing educational activities that focus on energy commercialization and entrepreneurship at their institutions. By presenting insights from 2024 entries to the Faculty Track, we hope to contribute to a growing inventory of open-source curriculum development resources and provide materials to facilitate the growth of similar programs at a variety of collegiate institutions.

adoption readiness level↗

U.S. Commercial Building Stock Analysis of COVID-19 Mitigation Strategies

The COVID-19 pandemic highlights the importance of improving building indoor air quality to reduce occupants' chances of contracting airborne illness. The ASHRAE Epidemic Task Force (ASHRAE-ETF) released several COVID-19 mitigation strategies at the onset of the pandemic. This study explores four of those recommendations for reducing transmission of COVID-19 inside buildings: (1) 100% outdoor air ventilation, (2) MERV-13 or better filters, (3) demand control ventilation removal, and (4) HVAC flushing mode. These recommendations were simulated and assessed using ComStock, a model of the U.S. commercial building stock. The study showed the 100% outdoor air ventilation recommendation had the largest impact on energy consumption, noncoincident peak demand, and thermostat violations. Removing demand control ventilation had the smallest national aggregate impact, installing MERV-13 filters led to slight increases in energy use and peak demand, and HVAC outdoor air flushing led to modest energy use and peak demand increases.

building energy modelling↗

A systematic feature extraction and selection framework for data-driven whole-building automated fault detection and diagnostics in commercial buildings

In data-driven automated fault detection and diagnostics (AFDD) modeling for building energy systems, feature engineering is a critical process of extracting information from high-dimensional and noisy sensor measurement and turning it into informative and representative inputs or features for data-driven modeling. However, few studies specifically discuss the feature engineering, especially the interactions between feature extraction and feature selection in whole-building AFDD. We developed a systematic feature extraction and selection framework for whole-building AFDD. In this framework, features are aggressively extracted from raw sensor data using statistical feature extraction techniques with various window sizes and statistics. With many features extracted, a hybrid feature selection algorithm that combines the filter and wrapper method then selects the best feature set. The framework considers diversity in the duration of fault behavior among fault types in whole-building AFDD, thus achieving high model generalization. We implemented our developed framework in a virtual testbed calibrated with measured data from Oak Ridge National Laboratory's Flexible Research Platform designed to mimic the operation of a typical small commercial building. The AFDD model is trained by the simulation data generated from the virtual testbed. The results show that (1) the developed framework improves the generalization of the AFDD model by 10.7% compared with literature-reported feature extraction and selection methods and (2) features with diverse window sizes and statistics are selected, providing insight into physical systems beyond the current understanding of buildings and faults and improving the detection and diagnostics of multiple fault types.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CH 4 combustion over a commercial Pd/CeO 2 -ZrO 2 three-way catalyst: Impact of thermal aging and sulfur exposure

Thermal aging and sulfur poisoning are major problems influencing the efficiency and lifetime of natural gas three-way catalysts (TWCs) during real-world operation. In the present study, thermal aging and sulfur-induced deactivations on CH 4 combustion were investigated over commercial monolithic honeycombs, i.e., Pd/CexZr 1-x O 2 (CZ)-based TWCs that are thermally aged in the bench (HTA), followed by being operated behind the stoichiometric natural gas engine in high sulfur fuel (HTA + S). In this work, both HTA and HTA + S samples show degraded performance in CH 4 combustion relative to the fresh one, which are caused by the reconstruction of Pd species induced by thermal aging and the decreased reducibility of the support. The 18 O 2 labelling experiments show that in all cases CH 4 combustion proceeds via a MvK mechanism in which lattice O (OL) plays a key role. The sulfation aging (HTA + S sample) promotes the activation of CH 4 and O 2 by forming Pd δ+ -(SO$_4^{2-}$) δ- and Ce 3+ -VO couples at the interface as compared to HTA sample. However, such a promotion effect could be compromised by the blocking effect of sulfate on the exchange of O L from the bulk to the surface and across the surface. The fundamental understanding of thermal and S deactivation mechanisms from this study could help to predict a real-world lifetime use curve of natural gas TWCs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Damage evolution and ductile fracture of commercially-pure titanium sheets subjected to simple tension and cyclic bending under tension

This paper describes a study into the evolution of damage in commercial-purity titanium (CP–Ti) sheets subjected to cyclic bending under tension (CBT) and uniaxial tension (simple tension, ST). Sections were taken from sheets that were strained to various levels under both methods and were imaged using X-ray computed tomography (XCT) to reveal insights into the size, density, and distribution of microvoids in the sheets. Digital image correlation (DIC) was also used to observe the surface strain of CBT and ST sheets during testing. These results showed that elongation to failure (ETF) for CBT deformation is about 2.5× higher than for ST, local longitudinal strains in the bulk of the CBT sample are around 1.3× higher than the peak strain in the ST necked region, and 1.7× higher in the localized region of CBT failure. It was found that the volume-density of voids in both sheets followed a similar exponential increase with strain, reaching nearly 45× higher in the CBT than the ST sheets before the onset of failure, mainly due to the higher strain levels achieved. A higher volume density of voids developed in the center of sheets at high levels of strain, for both processes, with the density in the sheet center becoming approximately double that found near the edges. Scanning electron microscopy (SEM) was used to examine the fracture surface of CBT and ST sheets after failure. The observations are presented and discussed highlighting the CBT process as effective to delay ductile fracture of the CP-Ti sheets.

Commercially pure titanium↗

Evaluation of thermostat location for multizone commercial building performance

In multi-zone buildings, it is often found that a single shared thermostat controls more than one conditioned zones. Although these shared zones are supposed to have similar thermal needs (e.g., cooling and heating load), in reality, they are not mainly due to different orientations, sizes of windows, occupancy, space types, etc. This can cause unnecessary energy waste or thermal discomfort for the occupants. How to quantify this impact in multizone buildings remains a research gap. Therefore, this study aims to evaluate the impact of different sensor (i.e., thermostat) locations for multizone commercial buildings through a comprehensive modeling study. Here, two different scenarios for the sensor locations were selected to evaluate the impact in terms of energy and thermal comfort. The scenario (1) is that one to five sensors distributed among the five zones, but the sensor readings from selected zones will be used for no-sensor zones, which is no-mean sensor scenario. The scenario (2) is that one to five sensors distributed among the five zones, but the average temperature from the shared zones will be used for each of the shared zones, which is a mean sensor scenario. The uncertainty analysis was performed for different sensor location scenarios.(a)The major findings from an energy perspective, for scenario (1), the differences of cooling energy go as high as 17% more or 12% less, compared with the baseline. For heating energy consumption, the discrepancies go as high as 51% more or 52% less, compared with baseline. For site energy consumption, the discrepancies go as high as 3.2% more or 3.2% less, compared with baseline. For fan energy consumption, the discrepancies go as high as 3.2% more or as low as 1.0% less, compared with baseline. For scenario (2), the discrepancies of cooling energy go as high as 3% more, or 0.5% less, compared with the baseline. For heating energy consumption, the discrepancies, are go as high as 10.1% more or as low as 3.0% less, compared with baseline. For site energy consumption, the discrepancies go as high as 1.3% more or 0.3% less, compared with baseline. For fan energy consumption, the discrepancies go as high as 3.1% more or as low as 1.0% less, compared with baseline.(b) In terms of the indoor thermal comfort, for the no-mean-sensor scenarios, the discrepancies of unmet hours for cooling mode can be as high as 1,200 h, compared with the baseline. The discrepancies of unmet hours for heating mode can be as high as 740 h, compared with the baseline. For the mean-sensor scenarios, the discrepancies of unmet hours for cooling mode can be as high as 750 h, compared with the baseline. The discrepancies of unmet hours for heating mode can be as high as 50 h, compared with the baseline.

42 ENGINEERING↗

Rare Earth Production in the United States: A Concise Review of Resource Development and Commercial Processes

This review article presents a concise review of estimated resources, processing methods and challenges involved in domestic rare earth mining projects in the United States (US). It also highlights the current status of major mining projects, anticipated rare earth production in the near future, and commercial projects utilizing non-traditional feedstocks for rare earth production and recycling. Based on the current industry outlook, opportunities for R&D have also been highlighted. Perspective on domestic rare earth production capability is essential because global rare earth production is currently dominated by China. Given potential export controls by China, this imbalance has created supply chain risk. The US and other countries have limited rare earth production capacity and relatively little expertise in rare earth processing. However, in the last decade, efforts have been made by several nations, including the US, to reduce their reliance on China for rare earth and other critical minerals. The US is currently investing in projects to develop domestic rare earth separation and refining capacity. These projects are discussed here. When backed by R&D and government support, these projects have potential to make significant progress towards establishment of domestic rare earth separation capabilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Understanding Advanced Vehicle Technology Adoption Potential in Commercial Fleets Across Major Trucking Sectors

Adopting advanced vehicle technologies, such as battery-electric, hybrid, and hydrogen fuel cell vehicles, can be an effective strategy for reducing fleet owners' operating costs. However, different trucking sectors, such as private and for-hire carriers and short- or long-haul operations, may face unique challenges in adopting those vehicle technologies due to their own operational needs and budget constraints. Current studies on fleet-wide vehicle technology projections frequently overlook such sectoral differences and fail to capture variation in adoption potential across sectors. This study addresses this gap by analyzing the disparities in the total cost of ownership (TCO) and payback period (PBP) among a large and heterogeneous sample of fleet owners. It aims to understand the sectoral differences in the long-term potential for adopting advanced vehicle technologies. Utilizing the 2021 US Vehicle Inventory and Use Survey (US VIUS), which offers data on various commercial vehicle sectors, their operational patterns, and current vehicle assets, this research estimates the TCO and PBP for individual trucks over multiple future years. The results reveal variation in the cost-effectiveness of different vehicle technologies across trucking sectors, as well as the potential technology landscape in both the short and long term. The findings from this study can inform policymakers and practitioners on how to prioritize sectors with lower barriers for advanced vehicle technology adoption and support industries that face challenges in switching to advanced vehicles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Decarbonizing or illusion? How carbon emissions of commercial building operations change worldwide

To lead the low-carbon transition in global buildings, this study is the first to use the generalized Divisia index method (GDIM) to identify the factors driving carbon emissions and assess the decarbonization performance in commercial building operations (CBOs) of sixteen countries during 2000–2019. Results show that (1) while the global carbon emissions from CBOs have increased at a modest rate of 0.9%/yr, this trend runs counter to the declining emissions in the U.S. (-1.1%/yr) and the significant growth in China (14.4%/yr), which can be attributed to the impact of economy-related factors. (2) The U.S. and China, as the largest emitters, contributed 66.8% of the samples’ decarbonization of CBOs (919.1 million tons of carbon dioxide). (3) Most countries’ CBOs had a decarbonization efficiency level of less than 10%, except for Spain (27.8%). Spain excelled in both areas of per capita and per floor area with an average efficiency of nearly 30%. Moreover, ridge regression successfully confirms the stability of GDIM results and it should be noted GDIM has limitations in characterizing the end-use activity. Overall, this study tracks the historical decarbonization of global CBOs and offers benchmarks for different emitters to forecast the dynamic of building emissions along with economic booms.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization of commercial vehicles’ start-up operations from in-use data

Diesel engines produce disproportionate levels of emissions when the engine and after-treatment systems are operating at low temperatures. This situation arises most commonly when the vehicle is first started after overnight. To quantify emissions attributable to vehicle starts, a sizable collection of on-road commercial vehicle operating data is analyzed to identify start-up events and inspect associated emissions. Data was obtained from the National Renewable Energy Laboratory’s (NREL’s) Fleet DNA and from the Center for Environmental Research & Technology (CE-CERT). Included are 500 + diesel vehicles with more than 42,000 recorded days, drawn from 25 vocational categories across the United States. Analysis shows that vehicle behavior, in terms of engine cold- and warm-operation, starts per day, soak time, and warm-up duration, differs significantly between vehicle vocations. Also, weighting factors for cold- and hot-starts currently used in the U.S. Environmental Protection Agency’s Federal Test Procedure (FTP) for heavy-duty emissions certification accurately represent real-world operations. Although the FTP includes a comparable fraction of cold operation, the hot fraction is much shorter than real-world operation due to limited test duration. The investigation also revealed that real-world engines operate for a significant amount of time when the engine coolant is in the “hot-stabilized” region, but the selective catalytic reduction (SCR) temperature is below its effective operating temperature of 200 °C. Of the vehicles under investigation, almost 20% of their operational time is within this condition. Therefore, novel approaches to raise and maintain SCR temperature are highly required to further reduce engine emissions.

33 ADVANCED PROPULSION SYSTEMS↗

Evaluation of the Passive Cooling Potential of Thermal Mass Inherent in Medium to Large Commercial Buildings

Typical commercial construction inherently contains large surface areas of relatively thin mass located in the floor slabs. This research asks how effective this mass could be for passive cooling, relative to other mass depths, if it were to be exposed and used as thermal mass. Although much of the rich literature on thermal mass has been conducted with far greater mass depths, a more limited amount of research suggests that because the surface heat transfer rate is limited, the focus should be on the surface area of exposed mass, not its depth. This presents an opportunity for more buildings to behave more thermally massively, if the mass inherent in typical floor slabs contains utility, particularly over diurnal cycles. In all climates analyzed, it was found that there is a pronounced shoulder where energy savings from passive cooling of increasing mass depths was steep until roughly 7.5–10 cm, and beyond this point the achieved energy savings diminished rapidly. When considering the embodied energy of concrete, the incremental benefit of added mass beyond a typical topping slab of 10 cm does not justify the incremental embodied energy cost from a total energy standpoint alone.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗