Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Commercial Buildings Integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Open Data Integration (ODIN): A Concurrent, Distributed Message-Based Architecture and Framework for Disaster Response

The Runtime for Airspace Concept Evaluation (RACE) is an open-source software architecture and framework to build configurable, highly concurrent and distributed message-based systems that offer scalable, low-latency performance on commodity hardware. RACE was used in commercial aviation applications to rapidly build systems that span several machines (including synchronized displays), interface existing hardware simulators and other live data feeds, and incorporate sophisticated visualization components such as NASA WorldWind. These RACE applications validated elements of the FAA’s System Wide Information Management (SWIM) Program, handling up to 1000 messages/sec from diverse sources (SFDPS, TFM-DATA, TAIS, ASDE-X, ITWS and local ADS) for 4,500 simultaneous flights tracked in the next-generation air transportation system’s digital backbone. We have since generalized RACE to support Open Data Integration (ODIN) applications outside aviation. Systems built with RACE/ODIN can be deployed in the field, on commodity hardware, and operate with limited or intermittent connectivity to the outside world. Our primary use case is a web-server with local/persistent data storage that runs within and only serves the stakeholder network (e.g. an incident command post). We are tailoring the RACE/ODIN system to support wildland fire management for the upcoming NASA Wildland Fire Safety Demonstration Series. RACE-ODIN is under consideration for application in the Scalable Traffic Management for Emergency Response Operations project, or STEReO, which aims to create a system that can be deployed during emergencies, to coordinate multiple elements of disaster response. Such data sources predominantly come from existing services on the internet (e.g. weather and satellite data, imported from so called "edge servers") but can also include dynamic (real-time) data from computer simulations and within the stakeholder network (such as aircraft and personnel tracking information). We will present the architecture and ODIN system demonstration incorporating local data from instrumented power-line towers, interpolated weather data and geospatial data from space-based platforms.

Joseph C Coughlan↗

Open Data Integration (ODIN): A Concurrent, Distributed Message-Based Architecture and Framework for Disaster Response

The Runtime for Airspace Concept Evaluation (RACE) is an open-source software architecture and framework to build configurable, highly concurrent and distributed message-based systems that offer scalable, low-latency performance on commodity hardware. RACE was used in commercial aviation applications to rapidly build systems that span several machines (including synchronized displays), interface existing hardware simulators and other live data feeds, and incorporate sophisticated visualization components such as NASA WorldWind. These RACE applications validated elements of the FAA’s System Wide Information Management (SWIM) Program, handling up to 1000 messages/sec from diverse sources (SFDPS, TFM-DATA, TAIS, ASDE-X, ITWS and local ADS) for 4,500 simultaneous flights tracked in the next-generation air transportation system’s digital backbone. We have since generalized RACE to support Open Data Integration (ODIN) applications outside aviation. Systems built with RACE/ODIN can be deployed in the field, on commodity hardware, and operate with limited or intermittent connectivity to the outside world. Our primary use case is a web-server with local/persistent data storage that runs within and only serves the stakeholder network (e.g. an incident command post). We are tailoring the RACE/ODIN system to support wildland fire management for the upcoming NASA Wildland Fire Safety Demonstration Series. RACE-ODIN is under consideration for application in the Scalable Traffic Management for Emergency Response Operations project, or STEReO, which aims to create a system that can be deployed during emergencies, to coordinate multiple elements of disaster response. Such data sources predominantly come from existing services on the internet (e.g. weather and satellite data, imported from so called "edge servers") but can also include dynamic (real-time) data from computer simulations and within the stakeholder network (such as aircraft and personnel tracking information). We will present the architecture and ODIN system demonstration incorporating local data from instrumented power-line towers, interpolated weather data and geospatial data from space-based platforms.

Guillaume P Brat↗

The human dimensions of energy use in buildings: A review

The “human dimensions” of energy use in buildings refer to the energy-related behaviors of key stakeholders that affect energy use over the building life cycle. Stakeholders include building designers, operators, managers, engineers, occupants, industry, vendors, and policymakers, who directly or indirectly influence the acts of designing, constructing, living, operating, managing, and regulating the built environments, from individual building up to the urban scale. Among factors driving high-performance buildings, human dimensions play a role that is as significant as that of technological advances. However, this factor is not well understood, and, as a result, human dimensions are often ignored or simplified by stakeholders. This work presents a review of the literature on human dimensions of building energy use to assess the state-of-the-art in this topic area. The paper highlights research needs for fully integrating human dimensions into the building design and operation processes with the goal of reducing energy use in buildings while enhancing occupant comfort and productivity. This research focuses on identifying key needs for each stakeholder involved in a building's life cycle and takes an interdisciplinary focus that spans the fields of architecture and engineering design, sociology, data science, energy policy, codes, and standards to provide targeted insights. Greater understanding of the human dimensions of energy use has several potential benefits including reductions in operating cost for building owners; enhanced comfort conditions and productivity for building occupants; more effective building energy management and automation systems for building operators and energy managers; and the integration of more accurate control logic into the next generation of human-in-the-loop technologies. The review concludes by summarizing recommendations for policy makers and industry stakeholders for developing codes, standards, and technologies that can leverage the human dimensions of energy use to reliably predict and achieve energy use reductions in the residential and commercial buildings sectors.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Costs to Automate Demand Response - Taxonomy and Results from Field Studies and Programs

During the past decade, the technology to automate demand response (DR) in buildings and industrial facilities has advanced significantly. Automation allows rapid, repeatable, reliable operation. This study focuses on costs for DR automation in commercial buildings with some discussion on residential buildings and industrial facilities. DR automation technology relies on numerous components, including communication systems, hardware and software gateways, standards-based messaging protocols, controls and integration platforms, and measurement and telemetry systems. This report compares cost data from several DR automation programs and pilot projects, evaluates trends in the cost per unit of DR and kilowatts (kW) available from automated systems, and applies a standard naming convention and classification or taxonomy for system elements. Median costs for the 56 installed automated DR systems studied here are about $200/kW. The deviation around this median is large with costs in some cases being an order of magnitude great or less than the median. This wide range is a result of variations in system age, size of load reduction, sophistication, and type of equipment included in cost analysis. The costs to automate fast DR systems for ancillary services are not fully analyzed in this report because additional research is needed to determine the total cost to install, operate, and maintain these systems. However, recent research suggests that they could be developed at costs similar to those of existing hot-summer DR automation systems. This report considers installation and configuration costs and does include the costs of owning and operating DR automation systems. Future analysis of the latter costs should include the costs to the building or facility manager costs as well as utility or third party program manager cost.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enhancing Performance Contracts with Monitoring-Based Commissioning (MBCx)

To support federal and commercial building owners in understanding, procuring, and implementing monitoring-based commissioning (MBCx) software tools, this report provides an overview of their capabilities, the MBCx process, and how MBCx can be integrated into—and benefit—each phase of a performance contract. This report is intended to spur increased use of MBCx in performance contracts, whether an agency has previously installed or is considering adding MBCx at the time of their project. Additionally, case studies illustrate successful experiences using MBCx within performance contracts at a university campus and across a large number of buildings managed by the General Services Administration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Challenges in Making Metal Large-scale Complex Parts for Additive Manufacturing: A Case Study Based on the Additive Manufacturing Excavator (AME)

The Additive Manufacturing Excavator (AME) contained several key components that were 3D printed at The Manufacturing Demonstration Facility (MDF) of Oak Ridge National Laboratory (ORNL); it was presented at and performed a live demonstration for the CONEXPO 2017 exhibition in Las Vegas, Nevada in March of 2017. This paper presents challenges in building functional, large-scale metal parts based on a case study of the excavator. The excavator’s metal arm was 3D printed using a modified Wolf Robotics automated metal inert gas (MIG) welding cell. Tasks included designing a new type of slicer for the metal additive manufacturing (AM) process, integrating the slicing software with the Wolf Robotics system, developing the deposition process, characterizing geometric features and material properties, managing heat, designing mechanical components for metal AM, and developing a machining approach to achieve the final part. Two fully functional excavator arms were printed and machined. Integrated hydraulics passageways that also served as structural stiffeners were included in the build for demonstration purposes. As a direct result of this project, Wolf Robotics is now working towards a commercially available large-scale metal AM system.

Nycz, Andrzej↗

IN2 Profile: Go Electric Provides Grid Stabilizing Energy Service Solutions to Utilities

Through the Wells Fargo Innovation Incubator (IN²) program, Go Electric will validate their Link DR technology, which is an advanced, uninterruptable power supply that provides secure power, lowers facility energy costs, integrates renewables, and generates income from utility demand response programs. The IN² program launched in October 2014 and is part of Wells Fargo’s 2020 Environmental Commitment to provide $100 million to environmentally-focused nonprofits and universities. The goal is to create an ecosystem that fosters and accelerates the commercialization of promising commercial buildings technologies that can provide scalable solutions to reduce the energy impact of buildings. According to the Department of Energy, nearly 40 percent of energy consumption in the U.S. today comes from buildings at an estimated cost of $413 billion.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Building America Case Study: Evaluation of Residential Integrated Space/Water Heat Systems, Illinois and New York (Fact Sheet)

This multi-unit field demonstration of combined space and water heating (combi) systems was conducted to help document combi system installation and performance issues that needed to be addressed through research. The objective of the project was to put commercialized forced-air tankless combi units into the field through local contractors that were trained by manufacturers and GTI staff under the auspices of utility-implemented Emerging Technology Programs. With support from PARR, NYSERDA and other partners, the project documented system performance and installations in Chicago and New York. Combi systems were found to save nearly 200 therms in cold climates at efficiencies between about 80% and 94%. Combi systems using third-party air handler units specially designed for condensing combi system operation performed better than the packaged integrated combi systems available for the project. Moreover, combi systems tended to perform poorly when the tankless water heaters operating at high turn-down ratios. Field tests for this study exposed installation deficiencies due to contractor unfamiliarity with the products and the complexity of field engineering and system tweaking to achieve high efficiencies. Widespread contractor education must be a key component to market expansion of combi systems. Installed costs for combi systems need to come down about 5% to 10% to satisfy total resource calculations for utility-administered energy efficiency programs. Greater sales volumes and contractor familiarity can drive costs down. More research is needed to determine how well heating systems such as traditional furnace/water heater, combis, and heat pumps compare in similar as-installed scenarios, but under controlled conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization of Single-mode Chalcogenide Optical Fiber for Mid-Infrared Applications

Chalcogenide fibers display a wide transmission window ranging from 2-10.6 μm, ideally suited to the development of passive and active mid-infrared (MIR) sensors. They are essential building blocks for the integration and miniaturization of laser-based MIR optical systems for terrestrial, airborne and space-based sensing platforms. Single-mode chalcogenide fibers have only recently become commercially available and therefore performance data and standard reproducible processing techniques have not been widely reported. In this paper we present a method for producing high quality facets on commercial single-mode As-Se fibers with core and cladding diameters of 28.1 and 169.9μm respectively. The emitted beam profile from these fibers, using the 9.4μm line of a tunable CO 2 laser, showed the presence of leaky cladding modes due to waveguiding conditions created by the protective acrylate jacket. These undesirable cladding modes were easily suppressed by applying a gallium coating on the cladding near both input and output facets. We provide experimental data of efficient mode suppression and the emission of a circular near-perfect Gaussian beam profile from the fiber. A model to determine appropriate placement of gallium coatings to minimize processing while maximizing cladding mode suppression is currently underway. Furthermore, analyses of the beam, acquired by scanning an HgCdTe detector, yielded a 1/e 2 numerical aperture of 0.11 with a full width half maximum divergence of 11° for these fibers. The availability of single-mode MIR fibers, in conjunction with recent advances in room temperature quantum cascade lasers (QCL), could provide compact and light-weight transmitter solutions for several critical defense and nuclear non-proliferation needs.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Status of SPCA-ANL Software Development, Software Quality Assurance, and Application (FY2025)

SPCA-ANL is a simulation tool used to perform deterministic analyses of sodium spray and pool fires. Development of the SPCA-II (Spray Pool Combustion Analysis) code began in the mid- 1980s as part of the Clinch River Breeder Reactor (CRBR) Project. At that time, development of SPCA-II, which was led by Rockwell International, was focused on treatment of large-scale sodium spray, stream, and pool fires that were anticipated to be prototypic of the steam generator building cells in CRBR. Under more recent DOE NE programmatic activities, the SPCA-II code was recovered from existing literature and underwent minor modifications to generate a stable executable. This recovered version of the code was not formally released. As part of the Versatile Test Reactor (VTR) Project in the 2010s, the SPCA-II code underwent key modifications to improve stability, address modeling deficiencies, improve consistency between the code manual and software, and address numerous bugs. At this point, SPCA-II was renamed SPCA-ANL. Given that SPCA-II served as the original basis for SPCA-ANL, both codes share an integrated history. Following termination of the VTR Project, the DOE NE Fast Reactor Program resumed support of the software with the goal of building and maintaining software infrastructure that can enable commercial-grade dedication of SPCA-ANL by an end user. Version 1.0, the first external release of SPCA-ANL, was generated in June 2024. This report summarizes the development and maintenance activities completed for SPCAANL in FY2025. This year’s work was focused on improving quality and usability of the code. The provisional Software Quality Assurance (SQA) program has been established and was used to test the procedures for infrastructure improvements, code development, bug fixes, and code releases, as described in the following sections of this report. A code Version 1.0.1 was released in FY25, as described in Chapter 4.

97 MATHEMATICS AND COMPUTING↗

DISSPATCH H2: Assessing Subsurface Storage Potential for Hydrogen

This project evaluates the technical feasibility of long-term underground hydrogen storage in the Anadarko Basin, integrating subsurface science, reservoir engineering, and system-level analysis to build a cohesive understanding of how hydrogen may be stored and recovered in porous media. Although salt caverns currently dominate commercial-scale hydrogen storage, their limited geographic availability necessitates alternative options that can support a more resilient energy system. Depleted oil and gas reservoirs offer a widely distributed and potentially high-capacity solution, but their suitability depends on formation-specific geologic, petrophysical, microbial, and operational factors. This study provides the first coordinated assessment of these factors within the Simpson Group of Oklahoma.

03 NATURAL GAS↗

CLIPS application user interface for the PC

The majority of applications that utilize expert system development programs for their knowledge representation and inferencing capability require some form of interface with the end user. This interface is more than likely an interaction through the computer screen. When building an application the user interface can prove to be the most difficult and time consuming aspect to program. Commercial products currently exist which address this issue. To keep pace C Language Integrated Production System (CLIPS) will need to find a solution for their lack of an easy to use Application User Interface (AUI). This paper represents a survey of the DoD CLIPS' user community and provides the backbone of a possible solution.

Jenkins, Jim↗

An open control sequence specification to scale building demand flexibility via analytics software

For over two decades, researchers and practitioners have showcased the ability of large commercial buildings to provide grid services by shedding or shifting load. Various utility demand response (DR) and virtual power plant (VPP) programs throughout the United States are presently utilizing these demand-side resources. However, growth of these programs have been limited, in part due to the high cost necessary to integrate the DR control strategies into the building automation system (BAS). Implementing these strategies involves adjusting control sequences, necessitating dozens of hours of customized programming per building, limiting their adoption to large organizations and progressive owners. Recent efforts by researchers and industry have demonstrated the capability of energy management and information systems (EMIS), originally designed for fault detection and diagnostics, to interface with existing BAS and perform supervisory control to optimize building operations. While these approaches are quickly being adopted by industry, demand flexibility (DF) control strategies remain limited in product offerings. One of the challenges is the lack of documented best-practice DF sequences, despite the rich literature on field implementations. This paper develops a new open-specification for a zone-based temperature adjustment shed strategy for commercial building HVAC systems, describing the specification’s implementation in two EMIS tools in both experimental and field settings. Both implementations successfully reduced electric load by at least 40% on average during the called event, while maintaining temperature limits. This study’s detailed process from specification to deployment shows the potential for scalability as well as highlights challenges related to integration with heterogeneous BAS products.

Granderson, Jessica↗

Continuation Power Flow Analysis for PV Integration Studies at Distribution Feeders

This paper presents a method for conducting continuation power flow simulation on high-solar penetration distribution feeders. A load disaggregation method is developed to disaggregate the daily feeder load profiles collected in substations down to each load node, where the electricity consumption of residential houses and commercial buildings are modeled using actual data collected from single family houses and commercial buildings. This allows the modeling of power flow and voltage profile along a distribution feeder on a continuing fashion for a 24- hour period at minute-by-minute resolution. By separating the feeder into load zones based on the distance between the load node and the feeder head, we studied the impact of PV penetration on distribution grid operation in different seasons and under different weather conditions for different PV placements.

AC Chronological Power Flow↗

DSO+T: Integrated System Simulation (DSO+T Study: Volume 2)

This report summarizes an integrated co-simulation model used by the Distribution System Operator with Transactive (DSO+T) study to represent an electrical generation, delivery, and end-load systems for the purposes of assessing the viability and value proposition of transactive energy coordination of flexible assets versus a business-as-usual case. The integrated co-simulation model includes the bulk generation and transmission system, including the day-ahead and real-time scheduling and dispatch of thermal generators. Forty distribution system operators were modelled in detail, including tens of thousands of residential and commercial buildings and their flexible end-loads. These included HVAC systems, residential water heaters, electric vehicles, and stationary, behind-the-meter, batteries. Both wholesale market and end-load results for the business-as-usual case are presented and compared to actual ERCOT system data to assess the accuracy and representativeness of the resulting model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Parametric study of solid-solid translucent phase change materials in building windows

Thermal energy storage and solar radiation management are crucial to improve the sustainability and energy efficiency of buildings. Compared with the implementation of phase change materials (PCMs) in opaque components, the energy saving potential of incorporating PCMs in transparent glazing windows is much less studied and not well understood. Here we present a comprehensive parametric study of novel PCM windows for building energy saving with a focus on optimizing and quantitatively distinguishing the contributions from the optical and thermal properties of the PCM, which is particularly useful for the design of solid-solid PCM windows. We investigate a reference commercial office building using EnergyPlus by developing an equivalent model of our PCM window that is compatible with EnergyPlus's modeling capabilities. Compared with a clear-clear double-pane window, the integration of 3 mm solid-solid PCMs with optimal properties in warm, mixed, and cold climates can respectively save up to 17.2%, 14.0%, and 5.8% energy for the HVAC (heating, ventilation, and air conditioning) system, and 9.4%, 6.7%, and 3.2% energy for the whole building. We also demonstrate that these energy savings are most sensitive to the solar absorptance of PCMs for all three climates. The optimal transition temperature varies with climate and is related to the climate and solar radiation heat gain. Other issues are also briefly discussed, such as hysteresis, window orientations, and the effect of interior lighting. Finally, although the optimal PCM windows show energy saving performance comparable with low-emissivity windows, the PCM windows provide a unique advantage in terms of shifting HVAC loads which can provide benefits to the electrical grid.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluating the Impact of Off-Design CHP Performance on the Optimal Sizing and Dispatch on Hybrid Renewable-CHP Distributed Energy Resources

The maturation of distributed energy resources (DER) has prompted the exploration of their deployment in commercial building applications due to their potential to supply energy at lower costs and emissions rates compared to centralized generation. While several software tools exist for evaluating the techno-economic potential of integrated renewable energy and combined heat and power (CHP) systems for distributed generation applications, many suffer from poor accuracy in capturing off-design (part load and changes in ambient air temperature and pressure) performance characteristics of microturbines, combustion turbines, or internal combustion engines. Thus, this paper presents a methodology for integrating these off-design characteristics in the mixed-integer linear program within REopt, a hybrid DER screening tool. The economic impact of the CHP off-design performance is observed through several application studies of various hybrid system configurations in different climates. Each study indicates how CHP off-design performance influences optimal sizing and dispatch decisions and therefore overall system economic value. We observe through case studies that modeling without the off-design effects, depending on the CHP prime mover and site, can result in Net Present Value predictions of hybrid systems that can be overoptimistic in frequently hot climates (up to 52%), too conservative in frequently cold climates (up to 11%), or unaffected (+/-1%) in temperate climates. Cases also highlight several advantages of hybrid systems relative to non-hybrid systems such as total economic value and the systems' ability to mitigate potentially negative consequences attributed to off-design performance.

ambient de-rate↗

HP-FLEX: Field demonstration of the semantics-driven configuration of a Model Predictive Control system to make heat pumps flexible

Model Predictive Control (MPC) has demonstrated significant potential for optimizing building operations and enabling demand flexibility. However, the widespread adoption of MPC is hindered by complex manual configuration and commissioning processes that must be conducted by control experts working alongside building operators. These challenges drive up costs and reduce scalability, particularly when technical human resources and building automation systems are limited, such as in small and medium commercial buildings (SMCBs). This paper demonstrates how semantic standards, specifically ASHRAE 223P, can accelerate the adoption of MPC applications for load flexibility in SMCBs. The authors present a replicable control framework, titled “HP-FLEX” that leverages a building’s semantic model to bootstrap the required data configuration for an MPC controller developed for optimizing heat pump systems as flexible grid resources. The semantic model helps streamline the deployment workflow, particularly for site setup, data/control commissioning, and model setup. This integration enhances portability, transferability, and scalability of the HP-FLEX MPC, which has been developed to support MPC-based supervisory HVAC controllers in SMCBs. Additionally, the paper details the required building and thermostat metadata information to enable the HP-FLEX MPC based on field demonstrations. The new workflow was tested in a small commercial building located in California, U.S., and demonstrated a load shifting performance of 9% based on a dynamic pricing signal that varies by the hour. This work provides a practical pathway for transitioning sophisticated building applications from custom to standardized semantic representations, supporting the broader adoption of advanced control strategies like MPC. The framework also establishes a foundation for evolving metadata requirements as applications mature while maintaining compatibility with industry standards.

Paul, Lazlo↗