Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Collective motion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Influence of Load Profile on Biomechanics of the Squat and Deadlift

Long duration space travel will expose astronauts to extended periods of reduced gravity. Since gravity is not present to assist loading, astronauts will use resistive and aerobic exercise regimes for the duration of the space flight to counteract the effect reduced gravity has on the body. Astronauts will exercise on a flywheel based device on the second Orion Exploration Mission (EM2). The effect that the flywheel load profile has on biomechanics is unknown when compared to free weights or a simulated free weight profile. The purpose of this evaluation is to compare the differences in lower body kinematics and kinetics between the flywheel and free weight profile. Test subjects were instrumented with reflective markers for motion capture data collection while exercising on the Device for Aerobic and Resistive Training (DART) prototype developed by TDA Research, Inc. of Wheat Ridge, CO. Exercises performed were either the squat while wearing a harness or deadlift while grasping a T-bar, both of which interfaced with the DART through a rope cable. The DART, a motorized device controlled via software, is capable of producing different load profiles. Profiles include simulated free weights with adjustable eccentric overload capability and flywheel. Test variables included the applied device load and the load profile, both set through the DART software interface. Motion capture data was collected with a 12 camera system (Smart-DX, BTS Bioengineering, Brooklyn, NY). Bilateral ground reaction force data were collected with force plates (P6000, BTS Bioengineering). DART cable force was recorded through an internal load cell. Data was collected from a total of four test subjects. The three repetition maximum was determined for each test subject for both squat and deadlift. High, medium and low loads were determined based on this maximum. The test subject performed five repetitions of each exercise at each load and each test trial was repeated twice. Cadence was controlled during exercising. Biomechanical data were used to drive the models utilizing the OpenSim software platform. Subject specific models were scaled to match the anthropometrics of the test subjects and used to estimate the peak joint angle, joint range of motion, the peak joint moment and the joint moment impulse of the lower extremity joints and the lumbar joint.These are preliminary results because the data analysis is ongoing. There was a lot of inter-subject variability, however, in general, there was a greater peak lumbar flexion angle for the flywheel squat exercise. There was a trend towards a greater range of motion at the hip for the squat exercise with free weight. There was also a greater hip extension, lumbar extension and ankle plantar flexion impulse moment during the squat exercise with free weight. During the deadlift exercise, the peak knee flexion angle and peak knee extension moment were greater when using the free weight profile. For deadlift, the hip extension, lumbar extension and ankle plantar flexion impulse moment tended to be greater with the free weight profile. Overall, the kinematic and kinetic outcomes for the flywheel profile were either statistically the same as free weight profile in many cases, significantly reduced in a few cases, and rarely higher.

Bioengineering↗

Intermediate scattering functions of a rigid body monoclonal antibody protein in solution studied by dissipative particle dynamic simulation

In the past decade, there was increased research interest in studying internal motions of flexible proteins in solution using Neutron Spin Echo (NSE) as NSE can simultaneously probe the dynamics at the length and time scales comparable to protein domain motions. However, the collective intermediate scattering function (ISF) measured by NSE has the contributions from translational, rotational, and internal motions, which are rather complicated to be separated. Widely used NSE theories to interpret experimental data usually assume that the translational and rotational motions of a rigid particle are decoupled and independent to each other. To evaluate the accuracy of this approximation for monoclonal antibody (mAb) proteins in solution, dissipative particle dynamic computer simulation is used here to simulate a rigid-body mAb for up to about 200 ns. The total ISF together with the ISFs due to only the translational and rotational motions as well as their corresponding effective diffusion coefficients is calculated. The aforementioned approximation introduces appreciable errors to the calculated effective diffusion coefficients and the ISFs. For the effective diffusion coefficient, the error introduced by this approximation can be as large as about 10% even though the overall agreement is considered reasonable. Thus, we need to be cautious when interpreting the data with a small signal change. In addition, the accuracy of the calculated ISFs due to the finite computer simulation time is also discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Redox-Promoting Protein Motions in Rubredoxin

Proteins are dynamic objects, constantly undergoing conformational fluctuations, yet the linkage between internal protein motion and function is widely debated. This manuscript reports on the characterization of temperature-activated collective and individual atomic motions of oxidized rubredoxin, a small 53 residue protein from thermophilic Pyrococcus furiosus (RdPf), by neutron scattering and computational simulations. The changes in motion have been explored in connection to their role in promoting reduction of the Fe+3 ion which is responsible for the electron transfer function of RdPf. Just above the dynamical transition temperature of 220 K which marks the onset of significant anharmonic motions of the protein, the computer simulations show both a significant reorientation of the average electrostatic force experienced by the Fe+3 ion and a dramatic rise in its strength. At higher temperatures, additional anharmonic modes become activated which dominate the electrostatic fluctuations experienced by the ion. At 360 K, close to the optimal growth temperature of Pyrococcus furiosus, computer simulations show that three anharmonic modes involving two conserved residues located at the protein active site (Ile7 and Ile40) give rise to the majority of the electrostatic fluctuations experienced by the Fe+3 ion and include displacements which allow solvent access to the ion. The low-frequency, high amplitude motions of these residues at low temperatures may be precursors of the high temperature, anharmonic motions necessary for protein function.

59 BASIC BIOLOGICAL SCIENCES↗

Microscopic derivation of five-dimensional collective Hamiltonian of large-amplitude quadrupole motion: application to shape coexistence in proton-rich Se isotopes

We present a new microscopic approach which consists of the constrained Hartree-Fock-Bogoliubov (CHFB) and the local quasiparticle random-phase approximation (LQRPA) to construct the five-dimensional quadrupole collective Hamiltonian for large-amplitude collective dynamics. The excitation spectra and the electric quadrupole transitions between the low-lying states in {sup 68}Se are calculated by solving the collective Schroedinger equation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evolution of the N = 40 neutron subshell in 20 ≤ Z ≤ 30 nuclei within the dispersive optical model

The evolution of single-particle neutron spectra in the N = 40 isotones {sup 60}Ca, {sup 62}Ti, {sup 64}Cr, {sup 66}Fe, {sup 68}Ni, and {sup 70}Zn is calculated on the basis of the mean-field model featuring a dispersive optical potential. The results of these calculations agree with the idea that the degree of collectivity becomes higher in the {sup 64}Сr nucleus and that the coupling of single-particle motion to this collectivity becomes stronger, as well as with available experimental data, which are indicative of the closure of the N = 40 subshell in {sup 68}Ni and of the trend toward this closure in {sup 60}Ca.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of the Test Section Walls at the 14- by 22-Foot Subsonic Tunnel

The test section walls of the NASA Langley Research Center 14- by 22-Foot Subsonic Tunnel are known to move under thermal and pressure loads. Videogrammetry was used to measure wall motion during the summer of 2002. In addition, a laser distancemeter was used to measure the relative distance between the test section walls at a single point. Distancemeter and videogrammetry results were consistent. Data were analyzed as a function of temperature and pressure to determine their effects on wall motion. Data were collected between 50 and 100 F, 0 and 0.315 Mach, and dynamic pressures of 0 and 120 psf. The overall motion of each wall was found to be less than 0.25 in. and less than facility personnel anticipated. The results show how motion depends on the temperature and pressure inside the test section as well is the position of the boundary layer vane. The repeatability of the measurements was +/-0.06 in. This report describes the methods used to record the motion of the test section walls and the results of the data analysis. Future facility plans include the development of a suitable wall restraint system and the determination of the effects of the wall motion on tunnel calibration.

Lunsford, Charles B.↗

Incorporation of Melittin Enhances Interfacial Fluidity of Bicontinuous Microemulsions

The effect of an antimicrobial peptide, melittin, on the long-range collective and local undulation motions of bicontinuous microemulsions (BμEs) was evaluated using dynamic light scattering (DLS) and neutron spin echo (NSE) spectroscopy. Small-angle neutron scattering (SANS) was also used to study the effect of melittin on the structure and the correlation length of BμEs. BμEs were isolated from Winsor-III systems formed by mixing aqueous melittin solutions containing sodium dodecyl sulfate with dodecane/1-pentanol mixtures at optimal salinity. An increase of melittin concentration linearly increased the diffusivity of the microemulsions (D DLS ) and decreased the bending rigidity (κ NSE ) up to an aqueous melittin concentration of 2 g/L, thus indicating an increase of interfacial fluidity. Further increase of melittin concentration above 2 g/L did not change D DLS and slightly increased κ NSE . The changes reflect differences of interaction between melittin and BμE surfactant monolayers at different melittin concentrations. At low concentrations, melittin is highly associated with the surfactant monolayers, likely ion-paired to the sulfate surfactant head groups and perhaps partially penetrating into the surfactant tail region. Above 2 g/L, an apparent saturation concentration, added melittin is less strongly associated with the monolayers. In contrast, the bare bending constant derived from SANS data (κ bare ) underwent only a minor decrease. Noting that κ bare reflects contributions from both the elasticity and saddle-splay moduli, this suggests that κ bare is not an effective indicator of dynamics for the BμEs investigated. Our study demonstrates that amphiphilic solubilizates can have a complex impact on dynamics of surfactant monolayers in microemulsions, with implications for transmembrane diffusion and the kinetics of release from the microemulsion phase, which are important characteristics for the use of BμEs as delivery vehicles and host systems for (bio)chemical reactions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Simulation of radioactive plume transport in the atmosphere including dynamics of particle aggregation and breakup

Accurate prediction of the atmospheric transport of debris particles relies heavily on our knowledge of the size distribution of the particles within a debris cloud. Assuming a fixed particle size during simulations is not always viable since the size distribution of the debris can change during transport. Various microphysical processes, such as aggregation and breakup, influence debris particles and dictate any changes to the size distribution. To track those changes that can occur, a population balance model can be adopted and instituted within a model framework. Nonetheless, many of the models that simulate the transport of radioactive debris following a device-driven fission incident have historically neglected to consider these processes. As such, this work describes our effort to develop a modeling framework capable of simulating the transport and deposition of a radioactive plume generated from a fission incident with a dynamic population balance including particle aggregation and breakup. Herein the impact of aggregation and breakup, individually and collectively, on the particle size distribution is explored using the developed framework. When simulating aggregation, for example, six mechanisms, including Brownian coagulation, the convective enhancement to Brownian coagulation, van der Waals-viscous force correction for Brownian coagulation, gravitational collection, turbulent inertial motion, and turbulent shear, are considered. Brownian coagulation and its corrections have, as one would expect, a large impact on relatively small aggregates. Aggregates with a diameter that is less than or equal to 1.0 μm, for instance, comprise 50.6 vol % of all aggregates in the absence of aggregation and 31.2 vol % when Brownian coagulation and its corrections are considered. Gravitational collection and, to a much lesser extent, turbulent shear and turbulent inertial motion are, conversely, of great importance to relatively large aggregates (i.e., diameter greater than 3.0 μm). Additionally, the individual effects of atmospheric and particle parameters, such as wind speed and particle density, are examined. Of the parameters examined, turbulent energy dissipation and aggregate fractal dimension (i.e., aggregate shape with lower values representing more irregular particles) were of substantial importance since both terms directly impact aggregate stability and, by extension, the breakup rate. Large-scale transport and deposition simulations in a dry atmosphere are also presented and discussed as a proof of concept.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Recent Improvements and Verification of A Full Body Model in Opensim

BACKGROUND: The dynamic feasibility [1,2] criterion, that the subject’s Center of Pressure (COP) be located within the Base of Support (BOS) which outlines the feet, has aided in assessing the stability of human motion recorded on earth while performing the recorded tasks in lunar gravity or as countermeasures exercises on a vibration isolation and stabilization system in microgravity. The convex hull of the BOS on the platform under the subject’s feet was estimated using virtual markers on the feet of the scaled subject model. The COP was calculated using the ground reaction forces and moments determined from motion capture data with biomechanical modeling tools [3]. Occasionally, large-amplitude oscillatory spikes or “artifacts” were observed in the subject’s linear and angular momentum derivatives, affecting some COP data derived from motion capture. The purpose of this investigation was to assess and improve the accuracy of model scaling and BOS estimation as well as to determine the efficacy of model adjustments in mitigating artifacts influencing motion capture-derived ground reaction force and COP results. METHODS: To aid evaluation of proposed process and model updates, motion capture data were collected for two subjects during unit test and range of motion trials, lunar tasks, and countermeasures exercise motions. Markers were added to the full body Plug-in Gait marker set [4] during data collection. New markers were placed on the front, back, sides, and top of the head to improve scaling using distances between marker pairs. Medial elbow markers were added to stabilize the upper arm during OpenSim Inverse Kinematics (IK) [5]. Finally, markers were added on the outer edge of the heels and on the outside edges of the first and last toes on each foot. These additional foot markers were made available to test new automated foot scaling techniques and to calculate the error between the subject’s estimated and recorded BOS. The modified unscaled OpenSim Full Body Rajagopal Model [6,7] was adjusted using some previously investigated techniques [8] to mitigate rapid shifts in joint angles occurring during IK, as these were found to cause the spike artifacts observed in subsequent stages of analysis. Since OpenSim models use Euler angles and rotation sequences, the arm axes of rotation were adjusted, and the pelvis order of rotation was changed to minimize the likelihood of encountering “gimbal lock” during common human motion. The model clavicle, arm, elbow, wrist, pelvis, and ankle angle limits were adjusted to better accommodate the full human range of motion seen in exercise and lunar data. The shoulder joint center was calculated using a “pivoting” algorithm [9], and both shoulder joint center and upper arm markers were included during IK to provide additional shoulder stability on a case-by-case basis. The quality of IK results was assessed by three criteria: minimizing error between recorded motion capture markers and model markers, checking for reasonable rates of change in joint angles between fames (i.e., no IK artifacts), and ensuring the absence of spikes in the inertial forces and angular momentum derivatives calculated using a custom OpenSim plugin [10]. RESULTS: The additional markers placed on the subject during data collection allowed the head and feet to be scaled more accurately using distances between new marker pairs. Scaling with BOS markers placed on the subject and removing the limit on subtalar angle resulted in more accurate BOS determination. Unrealistically large changes in joint angles between frames could be reduced by including clavicle, sternum, and medial elbow markers during IK. In cases with large arm ranges of motion, results could be further improved by running IK using medial elbow and virtual shoulder joint center markers. Model adjustments significantly improved the IK results affecting COP calculation and increased the accuracy of BOS estimation.

C A Bell↗

Focused Ultrasound Surgery Control Using Local Harmonic Motion: VX2 Tumor Study

The objective of this study was to develop a real-time method for controlling focused ultrasound surgery using ultrasound imaging. The approach uses measurements of localized harmonic motion (LHM) in order to perform controlled FUS exposures by detecting changes in the elastic properties of tissues during coagulation. Methods: Nine New Zealand rabbits with VX2 tumors implanted in the thigh were used for this study. LHM was generated within the tumors by periodic induction of radiation force using a FUS transducer (80-mm focal length, 100-mm diameter, 20-mm central hole, 1.485-MHz). Tissue motion was tracked by collecting and cross-correlating RF signals during the motion using a separate diagnostic transducer (3-kHz PRF, 5-MHz). After locating the tumor in MR images, a series of sonications were performed to treat the tumors using a reduction in LHM amplitude to control the exposure. Results: LHM was successfully used to control the sonications. A LHM amplitude threshold value was determined at which changes were considered significant and then the exposure was started and stopped when the LHM amplitude dropped below the threshold. The appearance of a lesion was then verified by MRI. The feasibility of LHM measurements to control FUS exposure was validated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CalWave - TEAMER UMaine 2021 Tank Testing

This is the data submission to the teamer report for RFTS1 during which tank testing at UMaine W2 tank occurred. This submission includes the relevant information and recorded data of CalWave's UMaine wave tank testing conducted under TEAMER Request for Support Round 1. During the testing CalWave assessed an autonomous control approach for changing PTO gain parameters based on "on board" sea state detection. The data submitted includes an overview of normalized PTO gains based on sea state values and for a set of 8 relevant sea states the WEC motion. All data was collected on CalWave's SCADA system and UMaine's motion tracking system. The data submitted suffices the creation of figures as shown in the PDF report submitted alongside the data and the submission includes excel sheets (parameter gains), MATLAB structures (absorber motion), and the mentioned PDF report.

16 TIDAL AND WAVE POWER↗

Dynamics and Control of a Tethered Enhanced Gravity Tractor Performing Asteroid Deflection

The dynamics and control of an Enhanced Gravity Tractor (EGT) augmented with a tether for deflecting an asteroid are studied. A conventional EGT consists of collected asteroidal mass collocated with the spacecraft. Because of the presence of a tether, the collected mass is placed where the EGT would have been without a tether, and the spacecraft is placed farther away from the asteroid. Doing so improves the fuel efficiency and safety margin of the EGT operation without significantly sacrificing the gravitational attraction between the asteroid and the EGT. The tether is modeled as a series of particles connected by spring-dashpot systems. Physical properties of the tether are selected to be similar to those of the SPECTRA-1000, Kevlar-29, and Kevlar-49 fibers. It is assumed that control is applied only to the spacecraft, and there is no active control associated with the collected mass. A Proportional-Derivative (PD) controller is employed to maintain the spacecraft and the collected mass at desired positions relative to the asteroid. Numerical simulations of tethered EGT operations at 2008 EV5, Itokawa, Apophis, and a fictitious ellipsoidal asteroid are performed. It is demonstrated that a PD controller is capable of accomplishing the control objectives. The gravity gradient and the control force keep the tether stretched throughout a normal tethered EGT operation, and the load on the tether is well within the design limit of the tether material. While including multiple particles in the tether model is essential in capturing details of tether vibration, the number of particles does not significantly affect the motions of the collected mass and the spacecraft. In addition, the distance from the asteroid mass center to the collected mass should be chosen judiciously in the case of a rotating slender asteroid; some distance ranges should be avoided as excessive lateral oscillations can be excited by resonance between the asteroid rotation and tether pendular motion.

Shen, Haijun↗

Biomechanical Modeling of Split-leg Squat and Heel Raise on the Hybrid Ultimate Lifting Kit (HULK)

Long duration space travel will expose astronauts to extended periods of reduced gravity. Since gravity is not present to aid loading, astronauts will use resistive and aerobic exercise regimes for the duration of the space flight to minimize the loss of bone density, muscle mass and aerobic capacity that occurs during exposure to a reduced gravity environment. Unlike the International Space Station (ISS), the area available for an exercise device in the next generation of spacecraft is limited and therefore compact resistance exercise device prototypes are being developed. The Advanced Resistive Exercise Device (ARED) currently on the ISS is being used as a benchmark for the functional performance of these new devices. Biomechanical data collection and computational modeling aid the device design process by quantifying the joint torques and musculoskeletal forces that occur during exercises performed on the prototype devices. Computational models currently use OpenSim software, an open source code for musculoskeletal modeling, with biomechanical input data from subjects for estimation of muscle and joint loads. Subjects are instrumented with reflective markers for motion capture data collection while exercising on the Hybrid Ultimate Lifting Kit (HULK) prototype device. Ground reaction force data is collected with force plates under the feet and device loading is recorded through load cells internal to the HULK. This data is input into the OpenSim biomechanical model, which has been scaled to match the anthropometrics of the test subject, to calculate the loads on the body. Multiple exercises are performed and evaluated during a test session such as a full squat, single leg squat, heel raise and dead lift. Variables for these exercises include applied device load, narrow or wide foot stance, slow or fast cadence and the harness or long bar interface between the test subject and the device. Data from free weights are compared to the resistively loaded exercise device. The focus of this presentation is to summarize the results from the single-leg squat and heel raise exercises performed during three sessions occurring in 2015. Differences in loading configuration, cadence and stance produce differences in kinematics, joint toques and force and muscle forces.

computational modeling↗

Squat Biomechanical Modeling Results from Exercising on the Hybrid Ultimate Lifting Kit

Long duration space travel will expose astronauts to extended periods of reduced gravity. Since gravity is not present to aid loading, astronauts will use resistive and aerobic exercise regimes for the duration of the space flight to minimize loss of bone density, muscle mass and aerobic capacity that occurs during exposure to a reduced gravity environment. Unlike the International Space Station (ISS), the area available for an exercise device in the next generation of spacecraft is limited and therefore compact resistance exercise device prototypes are being developed. The Advanced Resistive Exercise Device (ARED) currently on the ISS is being used as a benchmark for the functional performance of these new devices. Biomechanical data collection and computational modeling aid the device design process by quantifying the joint torques and the musculoskeletal forces that occur during exercises performed on the prototype devices. The computational models currently under development utilize the OpenSim software, an open source code for musculoskeletal modeling, with biomechanical input data from test subjects for estimation of muscle and joint loads. The subjects are instrumented with reflective markers for motion capture data collection while exercising on the Hybrid Ultimate Lifting Kit (HULK) prototype device. Ground reaction force data is collected with force plates under the feet and device loading is recorded through load cells internal to the HULK. Test variables include applied device load, narrow or wide foot stance, slow or fast cadence and the harness or long bar interface between the test subject and the device. Data is also obtained using free weights for a comparison to the resistively loaded exercise device. This data is input into the OpenSim biomechanical model, which has been scaled to match the anthropometrics of the test subject, to calculate the body loads. The focus of this presentation is to summarize the results from the full squat exercises across the different test variables.

Bioengineering↗

Stability of exact solutions of the (2 + 1)-dimensional nonlinear Schrödinger equation with arbitrary nonlinearity parameter κ

In this work, we consider the nonlinear Schrödinger equation (NLSE) in 2+1 dimensions with arbitrary nonlinearity exponent κ in the presence of an external confining potential. Exact solutions to the system are constructed, and their stability as we increase the 'mass' (i.e., the L 2 norm) and the nonlinearity parameter κ is explored. Here we observe both theoretically and numerically that the presence of the confining potential leads to wider domains of stability over the parameter space compared to the unconfined case. Our analysis suggests the existence of a stable regime of solutions for all κ as long as their mass is less than a critical value M*(κ). Furthermore, we find that there are two different critical masses, one corresponding to width perturbations and the other one to translational perturbations. The results of Derrick's theorem are also obtained by studying the small amplitude regime of a four-parameter collective coordinate (4CC) approximation. A numerical stability analysis of the NLSE shows that the instability curve M*(κ) versus κ lies below the two curves found by Derrick's theorem and the 4CC approximation. In the absence of the external potential, κ = 1 demarcates the separation between the blowup regime and the stable regime. In this 4CC approximation, for κ < 1, when the mass is above the critical mass for the translational instability, quite complicated motions of the collective coordinates are possible. Energy conservation prevents the blowup of the solution as well as confines the center of the solution to a finite spatial domain. We call this regime the 'frustrated' blowup regime and give some illustrations. In an appendix, we show how to extend these results to arbitrary initial ground state solution data and arbitrary spatial dimension d.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Coupled Multimodal Dynamics of Hydrogen-Containing Ion Networks in Water-Deficient, Sodium Hydroxide-Aluminate Solutions

The (meta)stability of low water activity sodium hydroxide/aluminate (Na + OH–/Al(OH) 4 –) electrolytes dictates kinetics in the Bayer process for aluminum refining and high-level nuclear waste processing. We utilized quasi-elastic neutron scattering (QENS) and proton nuclear magnetic resonance spectroscopy ( 1 H NMR) in extremely concentrated sodium aluminate solutions to investigate the picosecond (ps) to microsecond (ms) timescale motions of H-bearing species (Al(OH) 4 – monomers/clusters, OH– and H 2 O). In the QENS data, in contrast to typical liquids, no short-time translational diffusion was observed at 293 K, but two types of localized motions were found: (i) local backbone tumbling or a formation of large hydrated ion clusters on the order of 40–60 ps; and (ii) much slower, complex, and collective dynamics of the ensemble of H-bearing species on the order of 350–750 ps. Variable temperature, pulsed field gradient, diffusion-ordered 1H NMR was used to determine the ensemble translational motion along with relaxometry to calculate rotational correlation coefficients. The ensemble rotational correlation times were on the order of 184–300 ps from 1 H NMR, which is consistent with the timescale of the QENS components. Complementary molecular dynamics simulation of NaOH solutions exhibit extensive ion networks potentially responsible for the observed dynamical coupling of water with the motion of large hydrated ion clusters. Understanding these collective motions will aid in predicting the behavior of complex solutions during aluminum production and during nuclear waste processing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

String-Like Transport in Superionic Conductors

Superionic or fast-ion conductors are multicomponent solid-state systems in which one sublattice becomes mobile and exhibits extraordinarily high ionic conductivity before the melting within the solid state. Uranium dioxide (UO{sub 2}) - the fuel material of choice in most nuclear reactors - shows superionic behavior, although the mechanism of fast ion transport of the mobile oxygen ions, and its implication, is not well-understood. UO{sub 2} belongs to the category of Type II superionics wherein the conductivity rises gradually with increasing temperature, without an attendant phase change. In a recent work, using atomistic simulations and available neutron and x-ray scattering data, we have shown that all Type II superionic conductors exhibit a well-defined onset of dynamic disorder at a characteristic temperature T{sub α} = (∼2000 K for UO{sub 2}). Unlike the familiar superionic or Bredig transition temperature T{sub α} (∼2650 K for UO{sub 2}) that is associated with a second-order thermodynamic phase transition, T{sub α} represents an order-disorder (O-D) transition that marks a structural and kinetic crossover from a crystalline state to a semi-ordered state. In the temperature range between T{sub α} and T{sub λ}, the oxygen ions in UO{sub 2} exhibit jammed dynamics even though the mobile oxygen ions favor collective hopping from one native crystalline site to another. This cooperative dynamics manifests as dynamical heterogeneity (DH) - the tendency of highly mobile oxygen ions to form dynamic clusters, and dynamical facilitation (DF) - the mode of system relaxation facilitated solely through the kinetic ions transferring their mobility to neighboring ions. The jammed dynamics portrayed by the oxygen ions is similar to that observed in supercooled liquids and glassy materials, and other disordered systems such as granular media and polymers. In the current work, we probe the ionic dynamics in UO{sub 2} for the presence of another ubiquitous signature of glassy and jammed systems, namely, the one-dimensional string-like motion of the mobile species. Unlike the uncorrelated vacancy exchanges and interstitial migration in defected crystalline states, the string motion is a collective mechanism among the mobile species wherein each member of the string induces the next member to move in a correlated, sequential fashion. Using atomistic simulations, we demonstrate that oxygen ions in UO{sub 2} are transported through a string-like mechanism in the temperature range between T{sub α} and T{sub λ}, and the probability distribution of occurrence of the strings varies exponentially with string length. The discovery of string-like motion of the oxygen ions is somewhat surprising given the crystalline underpinning of the mobile species and the dynamic tendency of the oxygen ions to hop between lattice sites. In addition to dynamical heterogeneity and dynamical facilitation, our work has added one more entry, namely the occurrence of string-like transport, to the list of phenomenological similarities between superionic conductors and jammed systems. Using atomistic simulations, we have established the occurrence of string-like ionic motion among the oxygen ions in UO{sub 2} between temperatures T{sub α} - the order-disorder (O-D) transition temperature, and T{sub λ} - the Bredig transition temperature. As observed in other jammed systems, the length of the strings is observed to have an exponential distribution implying that the probability of occurrence of a smaller string is much higher than that of a longer string. Interestingly, using Temperature-Accelerated Dynamics (TAD) we have also established that string-like hopping takes place at temperatures lower than T{sub α}; these results will be published elsewhere. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Preliminary Sensorimotor and Cardiovascular Results from the Joint Russian/U.S. Pilot Field Test in Preparation for the Full Field Test

Ongoing collaborative research efforts between NASA's Neuroscience and Cardiovascular Laboratories, and the Institute of Biomedical Problems' (IBMP) Sensory-Motor and Countermeasures Laboratories have been measuring functional sensorimotor, cardiovascular and strength responses following bed rest, dry immersion, short-duration (Space Shuttle) and long-duration (Mir and International Space Station [ISS]) space flights. While the unloading paradigms associated with dry immersion and bed rest does serve as acceptable flight analogs, testing of crew responses following the long-duration flights previously has not been possible until a minimum of 24 hours after landing. As a result, it is not possible to estimate the nonlinear trend of the early (<24 hours) recovery process nor is it possible to accurately assess the full impact of the decrements associated with long-duration flight. To overcome these limitations, both the Russian and U.S. programs have implemented testing at the landing site. By joint agreement, this research effort has been identified as the functional Field Test (FT). For practical reasons the FT has been divided into two phases: the full FT and a preliminary pilot version (PFT) of the FT that is reduced in both length and scope. The primary goal of this research is to determine functional abilities in long-duration space-flight crews beginning as soon after landing as possible (< 2 hours) with one to three immediate follow-up measurements on the day of landing. This goal has both sensorimotor and cardiovascular elements, including evaluations of NASA's new anti-orthostatic compression garment and the Russian Kentavr garment. Functional sensorimotor measurements will include, but are not limited to, assessing hand/eye coordination, egressing from a seated position, walking normally without falling, measuring of dynamic visual acuity, discriminating different forces generated with both the hands and legs, recovering from a fall, coordinated walking involving tandem heel-to-toe placement, and determining postural ataxia while standing. The cardiovascular portion of the investigation includes measuring blood pressure and heart rate during a timed stand test in conjunction with postural ataxia testing (quiet stance sway) as well as cardiovascular responses during the other functional tasks. In addition to the immediate post-landing collection of data for the full FT, postflight data will be acquired between one and three more other times within the 24 hours after landing and will continue over the subsequent weeks until functional sensorimotor and cardiovascular responses have returned to preflight normative values. The PFT represents a single trial run comprised of a jointly agreed upon subset of tests from the full FT and relies heavily on IBMP's Sensory-Motor and Countermeasures Laboratories for content and implementation. The PFT has been collected on several ISS missions. Testing included: (1) a sit-to-stand test, (2) recovery from a fall where the crewmember began in the prone position on the ground and then stood for 3 minutes while cardiovascular stability was determined and postural ataxia data were acquired, and (3) a tandem heel-totoe walk test to determine changes in the central locomotor program. Video, cardiovascular parameters (heart rate and blood pressure), data from body-worn inertial sensors, and severity of postflight motion sickness were collected for each test session. In summary, the level of functional deficit is expected to be most profound during the acquisition of gravity loads immediately after landing when the demands for crew intervention in response to emergency operations will be greatest. Clearly measureable performance parameters such as ability to perform a seat egress, recover from a fall or the ability to see clearly when walking, and related physiologic data (orthostatic responses) are required to provide an evidence base for characterizing programmatic risks and the degree of variability among crewmembers for exploration missions where the crew will be unassisted after landing. Overall, these early functional and related physiologic measurements will allow estimation of nonlinear sensorimotor and cardiovascular recovery trends that has not been previously captured in over 50 years of space flight.

Reschke, M. F.↗