Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Coils”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Polyphase wireless power transfer systems, coil assemblies and resonant networks

Polyphase wireless power transfer systems are provided. The transfer system may be used for charging hybrid and electric vehicles. The systems are capable of transferring over 50 KW over an air gap of 15 cm. The systems use a rotating magnetic field to transfer power. The system may comprise transmitter coil assembly. The coil assembly may be one or more layers. The system may employ either unipolar or bipolar coils. The transmitter also comprises compensating capacitance connected in series with at least one coil for each phase. A value of the compensating capacitance for each phase is determined such that the transmitter has at least two independently excitable resonant modes at a resonant frequency. The transmitter is compatible with a plurality of different receivers including three-phase, single phase with a circular coil and single phase with DD coils.

Pries, Jason L.↗

Crystalline Structure in Thin Films of DEH-PPV Homopolymer And PPV-B-PI Rod-Coil Block Copolymers

The rod orientation and crystalline packing of a model semiconducting rodlike polymer, poly(2,5-di(2{prime}-ethylhexyloxy)-1,4-phenylenevinylene) (DEH-PPV), is shown to affect the self-assembly of weakly segregated rod-coil block copolymers. The in-plane packing of DEH-PPV rods in lamellar poly(2,5-di(2{prime}-ethylhexyloxy)-1,4-phenylenevinylene-b-isoprene) (DEH-PPV-b-PI) diblock copolymers is nearly identical to that observed in DEH-PPV homopolymers for compositions ranging from 0.42 to 0.82 vol % coil block. The crystal structure of DEH-PPV, characterized by grazing incidence X-ray diffraction and electron diffraction, consists of a tetragonal unit cell having c = 0.665 nm with a = b = 1.348 nm. The polymer chain axis is aligned along the [001] direction, and the nearest neighbor rod-rod spacing along 110 is 1.0 nm. As-cast thin films of DEH-PPV homopolymer demonstrate chain alignment primarily perpendicular to the substrate in 5100 g/mol homopolymer, while for 3500 g/mol homopolymer the chains align both perpendicular and parallel to the substrate. For the DEH-PPV-b-PI block copolymers, a sharper 001 reflection is observed due to the effect of microphase separation, improving alignment and stacking of the rods. The lamellar phases have a smectic A-like packing structure with the rods oriented parallel to the lamellar normal regardless of coil fraction; however, at coil fractions above about 0.8 the crystalline lattice of the rods becomes rapidly disordered as evidenced by loss of all but the two strongest Bragg reflections. This suggests that the constraints of packing into the unit cell outweigh the chain stretching and segment-segment repulsion energies that are predicted to lead to a transition from normal (smectic A) to tilted (smectic C) rod orientation within the lamellae at high coil fraction; increasing coil fraction breaks apart the crystalline lattice rather than distorting it into a tilted polymorph.

36 MATERIALS SCIENCE↗

Reproducibility of the coil positioning in Nb3Sn magnet models through magnetic measurements.

The random part of the integral field harmonics in a series of superconducting magnets has been used in the past to identify the reproducibility of the coil positioning. Using a magnetic model and a MonteCarlo approach, coil blocks are randomly moved and the amplitude that best fits the magnetic measurements is interpreted as the reproducibility of the coil position. Previous values for r.m.s. coil displacements for Nb-Ti magnets range from 0.05 to 0.01 mm. In this paper, we use this approach to estimate the reproducibility in the coil position for Nb{sub 3}Sn short models that have been built in the framework of the FNAL core program (HFDA dipoles) and of the LARP program (TQ quadrupoles). Our analysis shows that the Nb{sub 3}Sn models manufactured in the past years correspond to r.m.s. coil displacements of at least 5 times what is found for the series production of a mature Nb-Ti technology. On the other hand, the variability of the field harmonics along the magnet axis shows that Nb3Sn magnets have already reached values similar to these obtained for Nb-Ti ones.

43 PARTICLE ACCELERATORS↗

Fast Algorithm for Evaluating Critical Current of High-Temperature Superconducting Pancake Coil

Second-generation (2G) high-temperature superconducting (HTS) tapes are now capable of carrying very high transport current and promising for a wide range of applications. The critical current of HTS coils is important for applications, such as superconducting electric machines, superconducting magnetic energy storage, and superconducting magnets. Therefore, precisely and quickly calculating critical current of HTS coils is very important for designing HTS devices. This paper provides a fast algorithm for evaluating critical current of HTS pancake coil. The fast algorithm is realized through a stationary model, which is based on finite element method (FEM) software. The stationary model means that the model is solved by stationary study instead of time-dependent study. To validate this method, a pancake HTS coil was wound and its critical current was measured. Meanwhile, an axial symmetric stationary model was built according to the geometry of the measured HTS coil. By comparing measured and calculated results, the effectiveness of the stationary model was demonstrated. Moreover, the stationary model is compared with H formulation model. The calculated results by the two models are nearly the same. However, by using stationary calculation, the stationary model can remarkably speed up the computational process. Due to the advantage of calculating speed, the stationary model can be used to characterize and design large-scale HTS applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Mid-range adiabatic wireless energy transfer via a mediator coil

A technique for efficient mid-range wireless energy transfer between two coils via a mediator coil is proposed. By varying the coil frequencies, three resonances are created: emitter-mediator (EM), mediator-receiver (MR) and emitter-receiver (ER). If the frequency sweeps are adiabatic and such that the EM resonance precedes the MR resonance, the energy flows sequentially along the chain emitter-mediator-receiver. If the MR resonance precedes the EM resonance, then the energy flows directly from the emitter to the receiver via the ER resonance; then the losses from the mediator are suppressed. This technique is robust against noise, resonant constraints and external interferences. - Highlights: Black-Right-Pointing-Pointer Efficient and robust mid-range wireless energy transfer via a mediator coil. Black-Right-Pointing-Pointer The adiabatic energy transfer is analogous to adiabatic passage in quantum optics. Black-Right-Pointing-Pointer Wireless energy transfer is insensitive to any resonant constraints. Black-Right-Pointing-Pointer Wireless energy transfer is insensitive to noise in the neighborhood of the coils.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Proton deflectometry of a capacitor coil target along two axes

A developing application of laser-driven currents is the generation of magnetic fields of picosecond–nanosecond duration with magnitudes exceeding $B=10~\text{T}$. Single-loop and helical coil targets can direct laser-driven discharge currents along wires to generate spatially uniform, quasi-static magnetic fields on the millimetre scale. Here, we present proton deflectometry across two axes of a single-loop coil ranging from 1 to 2 mm in diameter. Comparison with proton tracking simulations shows that measured magnetic fields are the result of kiloampere currents in the coil and electric charges distributed around the coil target. Using this dual-axis platform for proton deflectometry, robust measurements can be made of the evolution of magnetic fields in a capacitor coil target.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

New printed circuit boards magnetic coils in the vacuum vessel of J-TEXT tokamak for position measurement

Four sets of magnetic diagnostic coils, which are printed on machinable ceramic printed circuit boards (PCB), are designed, fabricated, installed, and tested in the Joint Texas Experimental Tokamak (J-TEXT) vacuum vessel for detecting the plasma radial and vertical displacements relative to the geometric center of the vacuum vessel in Ohmic discharges. Each coordinate is determined by a pair of variable cross-section Rogowski and saddle coils, which measure the tangential and normal magnetic fields (relative to the coil surface). These coils are suitable for mass production and offer advantages in vacuum compatibility and temperature tolerance that are important for J-TEXT. Position measurements using PCB coils are compared with those from soft x-ray image system and match the position well.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Type-I superconductor pick-up coil in superconducting quantum interference device-based ultra-low field nuclear magnetic resonance

In ultra-low field nuclear magnetic resonance (ULF-NMR) with strong prepolarization field (B{sub p}), type-II superconducting pick-up coils may be vulnerable to flux pinning from the strong B{sub p}. Pick-up coils made of NbTi, Nb, and Pb were evaluated in terms of acquired NMR signal quality. The type-II pick-up coils showed degraded signals above 61 mT maximum exposure, while the Pb pick-up coil exhibited no such degradation. Furthermore, a negative counter pulse following a strong B{sub p} was shown to follow magnetic hysteresis loop to unpin the trapped flux in the type-II pick-up coil and restore the NMR signal.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Neutron resonance spin flippers: Static coils manufactured by electrical discharge machining

Radiofrequency spin flippers (RFSF) are key elements of Neutron Resonance Spin Echo (NRSE) spectrometers, which allow performing controlled manipulations of the beam polarization. We report on the design and test of a new type of RFSF which originality lies in the new manufacturing technique for the static coil. The largely automated procedure ensures reproducible construction as well as an excellent homogeneity of the neutron magnetic resonance condition over the coil volume. Two salient features of this concept are the large neutron window and the closure of the coil by a μ-metal yoke which prevents field leakage outside of the coil volume. These properties are essential for working with large beams and enable new applications with coils tilted with respect to the beam axis such as neutron Larmor diffraction or the study of dispersive excitations by inelastic NRSE.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diagnosing electric and magnetic fields in laser-driven coil targets

Laser-driven capacitor coils are widely used to generate intense magnetic fields for various applications in high-energy-density (HED) physics research. Accurate measurement of the magnetic fields is essential but challenging, due to the overlapping contributions from magnetic and electric fields in proton radiography, which is the primary tool diagnosing the field generation around the coils. In this study, we systematically analyze proton radiographs obtained from laser-driven capacitor-coil targets along two orthogonal axes under various electromagnetic field conditions, including magnetic field only, electric field only, and combined electromagnetic fields. By analyzing key features in the radiographs, we distinguish and characterize the respective contributions from magnetic and electric fields. Using detailed simulations validated by experimental benchmarks, methods to isolate and quantify the magnetic field and electric field are given. The methods are successfully applied to determine the electric current and charge distribution in a double coil configuration. Our findings provide insights into improving the diagnostic capability of proton radiography, potentially leading to more accurate measurements of electromagnetic fields and enhancing the utility of laser-driven capacitor coils in HED experiments.

electromagnetic field diagnostics↗

Forensic Analysis of Faulted NSTX-U Inner Poloidal Field Coil

The failure of the NSTX-U PF1A upper coil suspended plasma operations during the project's first operational campaign after commissioning. Initial nondestructive testing and examination of the failed coil was followed by extensive nondestructive radiography. Destructive testing facilitated visual borescope/videoscope inspection through the cooling path, vacuum testing, and electrical testing of every conductor segment. One conductor cooling path visually evidenced a void through the sidewall of the cooling path in a layer-to-layer region. The identified void in the conductor cooling path was not proximal to a braze or joggle. Electrical testing indicated that the voided conductor segment was a member of a group of 14 conductor segments that evidenced low-resistance connectivity. Four braze joints and two lead segments were subjected to 400-lbf/in 2 hydrostatic pressure testing followed by helium leak testing and evidenced that there were no detectable leaks in the tested cooling path segments. The faulted region was proximal to the center of the coil pack and evidenced historical electrical pitting and molten conductor debris. Samples of the epoxy resin insulation system were extracted and analyzed with dynamic mechanical analysis and differential scanning calorimetry techniques. Epoxy resin insulation samples were subjected to immersion testing per ASTM D570. Metallurgical samples were extracted from the coil pack conductors and subjected to hardness testing and grain structure analysis. The base material testing results indicated no abnormalities. In conclusion, the coil incipient failure was determined to most likely have resulted from conductive material located between conductor and insulation layers.

25 ENERGY STORAGE↗

Calibration and Localization of Optically Pumped Magnetometers Using Electromagnetic Coils

In this paper, we propose a method to estimate the position, orientation, and gain of a magnetic field sensor using a set of (large) electromagnetic coils. We apply the method for calibrating an array of optically pumped magnetometers (OPMs) for magnetoencephalography (MEG). We first measure the magnetic fields of the coils at multiple known positions using a well-calibrated triaxial magnetometer, and model these discreetly sampled fields using vector spherical harmonics (VSH) functions. We then localize and calibrate an OPM by minimizing the sum of squared errors between the model signals and the OPM responses to the coil fields. We show that by using homogeneous and first-order gradient fields, the OPM sensor parameters (gain, position, and orientation) can be obtained from a set of linear equations with pseudo-inverses of two matrices. The currents that should be applied to the coils for approximating these low-order field components can be determined based on the VSH models. Computationally simple initial estimates of the OPM sensor parameters follow. As a first test of the method, we placed a fluxgate magnetometer at multiple positions and estimated the RMS position, orientation, and gain errors of the method to be 1.0 mm, 0.2°, and 0.8%, respectively. Lastly, we calibrated a 48-channel OPM array. The accuracy of the OPM calibration was tested by using the OPM array to localize magnetic dipoles in a phantom, which resulted in an average dipole position error of 3.3 mm. The results demonstrate the feasibility of using electromagnetic coils to calibrate and localize OPMs for MEG.

47 OTHER INSTRUMENTATION↗

Lessons Learned During the Manufacture of the NCSX Modular Coils

The National Compact Stellarator Experiment's (NCSX) modular coils presented a number of engineering and manufacturing challenges due to their complex shapes, requirements for high dimensional accuracy and high current density requirements due to space constraints. Being the first of their kind, these coils required the implementation of many new manufacturing and measuring techniques and procedures. This was the first time that these manufacturing techniques and methods were applied in the production of coils at the laboratory. This resulted in a steep learning curve for the first several coils. Through the effective use of procedures, tooling modifications, involvement and ownership by the manufacturing workforce, and an emphasis on safety, the assembly team was able to reduce the manufacturing times and improve upon the manufacturing methods. This paper will discuss the learning curve and steps that were taken to improve the manufacturing efficiency and reduce the manufacturing times for the modular coils without forfeiting quality.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements on Subscale Y-Ba-Cu-O Racetrack Coils at 77 K and Self-Field

YBa{sub 2}Cu{sub 3}O{sub 7-{delta}} (YBCO) tapes carry significant amount of current at fields beyond the limit of Nb-based conductors. This makes the YBCO tapes a possible conductor candidate for insert magnets to increase the bore field of Nb{sub 3}Sn high-field dipoles. As an initial step of the YBCO insert technology development, two subscale racetrack coils were wound using Kapton-insulated commercial YBCO tapes. Both coils had two layers; one had 3 turns in each layer and the other 10 turns. The coils were supported by G10 side rails and waxed strips and not impregnated. The critical current of the coils was measured at 77 K and self-field. A 2D model considering the magnetic-field dependence of the critical current was used to estimate the expected critical current. The measured results show that both coils reached 80%-95% of the expected values, indicating the feasibility of the design concept and fabrication process.

43 PARTICLE ACCELERATORS↗

Endovascular Management of Visceral Artery Pseudoaneurysms: Transcatheter Coil Embolization Using the Isolation Technique

PurposeTo describe our experiences with treatment of visceral artery pseudoaneurysms (VAPA) by transcatheter coil embolization using an isolation technique and to propose indications for treating VAPA with this method.Materials and MethodsWe treated 37 patients with VAPA endovascularly: There were 15 pancreaticoduodenal arcade, 10 hepatic, 5 renal, 3 splenic, and 1 each left gastric, gastroepiploic, adrenal, and superior mesenteric artery pseudoaneurysms. Preprocedure computed tomography (CT) and/or angiographic studies confirmed the presence of VAPA in all 37 patients. Using the isolation technique, we embolized vessels at sites distal and proximal to the pseudoaneurysm.ResultsTranscatheter coil embolization with the isolation technique was technically successful in 33 (89%) of 37 patients, and angiogram confirmed the complete disappearance of the VAPA in 32 patients. No major complications occurred during the procedures. In a patient with a pancreaticoduodenal arcade artery pseudoaneurysm, we were unable to control hemorrhage. In 30 of 32 patients who recovered after transcatheter coil embolization using the isolation technique, follow-up CT scan showed no flow in VAPA; they survived without rebleeding. Two of the 32 patients (6%) with confirmed complete disappearance of VAPA on angiogram and CT scan obtained the day after the procedure manifested rebleeding during follow-up.ConclusionTranscatheter coil embolization using the isolation technique is an effective alternative treatment in patients with VAPA. In combination with coil embolization, the isolation technique is particularly useful in patients whose pseudoaneurysms present surgical difficulties.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Portal Vein Embolization before Right Hepatectomy: Improved Results Using n-Butyl-Cyanoacrylate Compared to Microparticles Plus Coils

Background: There is currently no consensus in the literature on which embolic agent induces the greatest degree of liver hypertrophy after portal vein embolization (PVE). Only experimental results in a pig model have demonstrated an advantage of n-butyl-cyanoacrylate (NBCA) over 3 other embolic materials (hydrophilic gel, small and large polyvinyl alcohol particles) for PVE. Therefore, the aim of this human study was to retrospectively compare the results of PVE using NBCA with those using spherical microparticles plus coils. Methods: A total of 34 patients underwent PVE using either NBCA (n = 20), or spherical microparticles plus coils (n = 14). PVE was decided according to preoperative volumetry on the basis of contrast-enhanced CT. Groups were compared for age, sex, volume of the left lobe before PVE and future remnant liver ratio (FRL) (volume of the left lobe/total liver volume - tumor volume). The primary end point was the increase in left lobe volume 1 month after PVE. Secondary end points were procedure complications and biological tolerance. Results: Both groups were similar in terms of age, sex ratio, left lobe volume, and FRL before PVE. NBCA induced a greater increase in volume after PVE than did microparticles plus coils (respectively, +74 {+-} 69 % and +23 {+-} 14 %, p < 0.05). The amount of contrast medium used for the procedure was significantly larger when microparticles and coils rather than NBCA were used (respectively, 264 {+-} 43 ml and 162 {+-} 34 ml, p < 0.01). The rate of PVE complications as well as the biological tolerance was similar in both groups. Conclusion: NBCA seems more effective than spherical microparticles plus coils to induce left-lobe hypertrophy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Amplatzer Vascular Plugs Versus Coils for Embolization of Pulmonary Arteriovenous Malformations in Patients with Hereditary Hemorrhagic Telangiectasia

PurposeCoil embolization of pulmonary arteriovenous malformations (PAVMs) has a high re-canalization/re-perfusion rate. Embolization with Amplatzer plugs has been previously described, but the long-term efficacy is not established. This study reports the experience of a referral medical center with the use of coils and Amplatzer plugs for treating PAVMs in patients with hereditary hemorrhagic telangiectasia.MethodsThe study was approved by the Institutional Review Board with waiver of informed consent. The cohort included all patients who underwent PAVM embolization in 2004–2014 for whom follow-up imaging scans were available. The medical files were retrospectively reviewed for background data, embolization method (coils, Amplatzer plugs, both), and complications. Re-canalization of treated PAVMs was assessed from intrapulmonary angiograms (following percutaneous procedures) or computed tomography angiograms. Fisher’s exact test and Pearson Chi-squared test or t test were used for statistical analysis, with significance at p < 0.05.Results16 patients met the study criteria. Imaging scans were available for 63 of the total 110 PAVMs treated in 41 procedures. Coils were used for embolization in 37 PAVMs, Amplatzer plugs in 21, and both in five. Median follow-up time was 7.7 years (range 1.4–18.9). Re-canalization was detected in seven vessels, all treated with coils; there were no cases of re-canalization in plug-occluded vessels (p = 0.0413).ConclusionThe use of Amplatzer plugs for the embolization of PAVMs in patients with hemorrhagic telangiectasia is associated with a significantly lower rate of re-canalization of feeding vessels than coils. Long-term prospective studies are required to confirm these findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Global stochastic optimization of stellarator coil configurations

In the construction of a stellarator, the manufacturing and assembling of the coil system is a dominant cost. These coils need to satisfy strict engineering tolerances, and if those are not met the project could be cancelled as in the case of the National Compact Stellarator Experiment (NCSX) project. Therefore, our goal is to find coil configurations that increase construction tolerances without compromising the performance of the magnetic field. In this paper, we develop a gradient-based stochastic optimization model which seeks robust stellarator coil configurations in high dimensions. In particular, we design a two-step method: first, we perform an approximate global search by a sample efficient trust-region Bayesian optimization; second, we refine the minima found in step one with a stochastic local optimizer. To this end, we introduce two stochastic local optimizers: BFGS applied to the sample average approximation; and Adam, equipped with a control variate for variance reduction. Numerical simulations performed on a W7-X-like coil configuration demonstrate that our global optimization approach finds a variety of promising local solutions at less than 0.1% of the cost of previous work, which considered solely local stochastic optimization.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗