Computer-aided detection of interstitial abnormalities in chest radiographs using a reference standard based on computed tomography

A computer-aided detection (CAD) system is presented for the localization of interstitial lesions in chest radiographs. The system analyzes the complete lung fields using a two-class supervised pattern classification approach to distinguish between normal texture and texture affected by interstitial lung disease. Analysis is done pixel-wise and produces a probability map for an image where each pixel in the lung fields is assigned a probability of being abnormal. Interstitial lesions are often subtle and ill defined on x-rays and hence difficult to detect, even for expert radiologists. Therefore a new, semiautomatic method is proposed for setting a reference standard for training and evaluating the CAD system. The proposed method employs the fact that interstitial lesions are more distinct on a computed tomography (CT) scan than on a radiograph. Lesion outlines, manually drawn on coronal slices of a CT scan of the same patient, are automatically transformed to corresponding outlines on the chest x-ray, using manually indicated correspondences for a small set of anatomical landmarks. For the texture analysis, local structures are described by means of the multiscale Gaussian filter bank. The system performance is evaluated with ROC analysis on a database of digital chest radiographs containing 44 abnormal and 8 normal cases. The best performance is achieved for the linear discriminant and support vector machine classifiers, with an area under the ROC curve (A{sub z}) of 0.78. Separate ROC curves are built for classification of abnormalities of different degrees of subtlety versus normal class. Here the best performance in terms of A{sub z} is 0.90 for differentiation between obviously abnormal and normal pixels. The system is compared with two human observers, an expert chest radiologist and a chest radiologist in training, on evaluation of regions. Each lung field is divided in four regions, and the reference standard and the probability maps are converted into region scores. The system performance does not significantly differ from that of the observers, when the perihilar regions are excluded from evaluation, and reaches A{sub z}=0.85 for the system, with A{sub z}=0.88 for both observers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Determination of elemental impurities in plastic calibration standards using laser induced breakdown spectroscopy

Dual-energy computed tomography (CT) scanning is a rapidly emerging imaging technique employed in nondestructive evaluation of various materials. CT has been used for characterizing rocks and visualizing multiphase flow through rocks for over 25 years. The most common technique for dual-energy CT scanning relies on homogeneous calibration standards to produce the most accurate decoupled data. However, the use of calibration standards with impurities increases the probability of error in the reconstructed data and results in poor rock characterization. Laser-induced breakdown spectroscopy was used to determine impurity concentration in a set of commercially purchased calibration standards used in dual-energy scanning for material identification with coal samples. Two calibration models were developed by using univariate calibration with the internal ratio method and multiple linear regression. Seven elements (Al, Fe, Mg, Na, Ni, Sr, and Ti) were examined in five different samples containing varying amounts of each ion to compare calibration from univariate data analysis and from multivariate data analysis. The contaminant concentrations were also measured by a commercially available inductively coupled plasma optical emission spectroscopy instrument, and the data were used as a reference in developing calibration curves for a modified version of the single linear regression model and the multiple linear regression model.

01 COAL, LIGNITE, AND PEAT↗

A method for patient dose reduction in dynamic contrast enhanced CT study

Purpose: In dynamic contrast enhanced CT (DCE-CT) study, prolonged CT scanning with high temporal resolution is required to give accurate and precise estimates of kinetic parameters. However, such scanning protocol could lead to substantial radiation dose to the patient. A novel method is proposed to reduce radiation dose to patient, while maintaining high accuracy for kinetic parameter estimates in DCE-CT study. Methods: The method is based on a previous investigation that the arterial impulse response (AIR) in DCE-CT study can be predicted using a population-based scheme. In the proposed method, DCE-CT scanning is performed with relatively low temporal resolution, hence, giving rise to reduction in patient dose. A novel method is proposed to estimate the arterial input function (AIF) based on the coarsely sampled AIF. By using the estimated AIF in the tracer kinetic analysis of the coarsely sampled DCE-CT study, the calculated kinetic parameters are able to achieve a high degree of accuracy. The method was tested on a DCE-CT data set of 48 patients with cervical cancer scanned at high temporal resolution. A random cohort of 34 patients was chosen to construct the orthonormal bases of the AIRs via singular value decomposition method. The determined set of orthonormal bases was used to fit the AIFs in the second cohort (14 patients) at varying levels of down sampling. For each dataset in the second cohort, the estimated AIF was used for kinetic analyses of the modified Tofts and adiabatic tissue homogeneity models for each of the down-sampling schemes between intervals from 2 to 15 s. The results were compared with analyses done with the ''raw'' down-sampled AIF. Results: In the first group of 34 patients, there were 11 orthonormal bases identified to describe the AIRs. The AIFs in the second group were estimated in high accuracy based on the 11 orthonormal bases established in the first group along with down-sampled AIFs. Using the 11 orthonormal bases, the estimated AIFs for the second group were found to have an averaged maximal percentage error of 3.4%{+-} 7.5% in all sampling schemes up to 15 s. The results of kinetic analysis with the proposed method compared with down sampling alone showed that the proposed method is superior in maintaining the accuracy in volume transfer constant (K{sup trans} ) after 9 s down-sampling interval, blood volume (v{sub b} ) for almost all down-sampling intervals, and blood flow (F) after 11 s down-sampling interval. The preliminary results suggested that the proposed method is able to support scanning intervals of 10-15 s at a cost of 6.2%-10.0% loss in accuracy of K{sup trans} and 10.9%-19.4% in v{sub b}, and the scanning intervals of 12-15 s at a cost of 9.7%-14.6% for F in DEC-CT studies for patients with cervix cancer. Conclusions: The proposed method of AIF estimation allows low scanning frequency in DCE-CT study to reduce radiation dose to patient, while maintaining relatively high accuracy in the kinetic parameter estimates. The initial results suggested that the method is applicable for DCE-CT studies for patients with cervical cancer.

60 APPLIED LIFE SCIENCES↗

SU-F-T-397: Evaluating the Impact of Bladder Filling Status for the Organs at Risk Dose Distribution in Cervical Cancer Patients with Intensity Modulated Radiotherapy

Purpose: To investigate the impact of bladder filling status of the organs at risk (OARs) on dose distribution during intensity modulated radiotherapy (IMRT) for cervical cancer patients. Methods: Twelve cervical cancer patients treated with IMRT were selected for this study. The prescription dose was 45Gy/25 fractions with the 6 MV photon beam. All patients performed two CT scans, one with an empty bladder, the other one with bladder filled. For the registration of two CT scans, the fusion was automatically carried out upon the bony anatomy. The OARs (bladder, rectum, pelvic bone and small intestine) were delineated to planning CT to evaluate the dose distributions. These dose distributions were compared between empty bladder and bladder filling. Results: The bladder volume with empty bladder and bladder filling was 403.2±124.13cc and 101.4±87.5cc, respectively. There were no statistical differences between empty bladder and bladder filling in the mean value of pelvic bone V10Gy, V20Gy, V40Gy; rectum V40Gy and V45Gy. The bladder V40Gy and V45Gy were lower in the bladder filling group than in the empty bladder group (63.7%±5.8% vs 87.5%±7.8%, 45.1%±9.5% vs 62.4%±11.8%, respectively). The V45Gy for small intestine in the bladder filling group was significantly less than the empty bladder group (146.7cc±95.3cc vs 245.7cc±101.8cc). Conclusion: Our study finds that the bladder filling status did not have a significant impact on dose distribution in the rectum and pelvic bone. However, the changes of bladder filling have a large impact on bladder and small intestine doses. A full bladder is strongly recommended during treatment for cervical cancer patients.

60 APPLIED LIFE SCIENCES↗

COBRA:COMPUTED-TOMOGRAPHY BASED RANDOM-FIELD APPROXIMATION

SF-25-115 COBRA (COmputed-tomography Based Random-field Approximation) is a Python application for generating statistically equivalent random fields from CT-scan imagery. It leverages Karhunen–Loève expansions to model microstructural variability, enabling users to: Preprocess CT scans (filtering and Gaussian transformation); Fit covariance kernels fromempirical data; Solve eigenproblems to obtain KL modes; Sample random fields onsistent with fitted statistics; Postprocess samples back into the physical domain.

Hu, Tianchen↗

Retrospective Analysis of Artifacts in Four-Dimensional CT Images of 50 Abdominal and Thoracic Radiotherapy Patients

Purpose: To quantify the type, frequency, and magnitude of artifacts in four-dimensional (4D) CT images acquired using a multislice cine method. Methods and Materials: Fifty consecutive patients who underwent 4D-CT scanning and radiotherapy for thoracic or abdominal cancers were included in this study. All the 4D-CT scans were performed on the GE multislice PET/CT scanner with the Varian Real-time Position Management system in cine mode. The GE Advantage 4D software was used to create 4D-CT data sets. The artifacts were then visually and quantitatively analyzed. We performed statistical analyses to evaluate the relationships between patient- or breathing-pattern-related parameters and the occurrence as well as magnitude of artifacts. Results: It was found that 45 of 50 patients (90%) had at least one artifact (other than blurring) with a mean magnitude of 11.6 mm (range, 4.4-56.0 mm) in the diaphragm or heart. We also observed at least one artifact in 6 of 20 lung or mediastinal tumors (30%). Statistical analysis revealed that there were significant differences between several breathing-pattern-related parameters, including abdominal displacement (p < 0.01), for the subgroups of patients with and without artifacts. The magnitude of an artifact was found to be significantly but weakly correlated with the abdominal displacement difference between two adjacent couch positions (R = 0.34, p < 0.01). Conclusions: This study has identified that the frequency and magnitude of artifacts in 4D-CT is alarmingly high. Significant improvement is needed in 4D-CT imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Method to measure orientation of discontinuous fiber embedded in the polymer matrix from computerized tomography scan data

Usage of discontinuous glass fibers in injection and compression molded resin components is rapidly increasing to improve their mechanical properties. Since added fiber contributes to more strength along the fiber direction compared to transverse direction, the mechanical properties of such components strongly depend on the fiber orientation. Thus it is important to estimate the fiber orientation distribution in such materials. Here, we are presenting recently developed method to estimate fiber orientation from 3D image of fibers generated using micro CT scan. Typically the 3D images from CT scan are very large and it becomes difficult to separate each fiber and extract end point information. In this paper a novel method to address this challenge is presented. The micro-CT images were broken into finite volume, reducing data size, and then each fiber was reduced to its own center line, further reducing the data size, using Mimics Innovation Suite (Materialise NV). These 3D centerlines were then used to quantify the 2nd order orientation tensor. Our results from the proposed method are compared with the measurements using well established industry standard approach called method of ellipses for validation. The key challenges in estimating the fiber orientation are identified and future improvements are proposed.

36 MATERIALS SCIENCE↗

Inferring Positions of Tumor and Nodes in Stage III Lung Cancer From Multiple Anatomical Surrogates Using Four-Dimensional Computed Tomography

Purpose: To investigate the feasibility of modeling Stage III lung cancer tumor and node positions from anatomical surrogates. Methods and Materials: To localize their centroids, the primary tumor and lymph nodes from 16 Stage III lung cancer patients were contoured in 10 equal-phase planning four-dimensional (4D) computed tomography (CT) image sets. The centroids of anatomical respiratory surrogates (carina, xyphoid, nipples, mid-sternum) in each image set were also localized. The correlations between target and surrogate positions were determined, and ordinary least-squares (OLS) and partial least-squares (PLS) regression models based on a subset of respiratory phases (three to eight randomly selected) were created to predict the target positions in the remaining images. The three-phase image sets that provided the best predictive information were used to create models based on either the carina alone or all surrogates. Results: The surrogate most correlated with target motion varied widely. Depending on the number of phases used to build the models, mean OLS and PLS errors were 1.0 to 1.4 mm and 0.8 to 1.0 mm, respectively. Models trained on the 0%, 40%, and 80% respiration phases had mean ({+-} standard deviation) PLS errors of 0.8 {+-} 0.5 mm and 1.1 {+-} 1.1 mm for models based on all surrogates and carina alone, respectively. For target coordinates with motion >5 mm, the mean three-phase PLS error based on all surrogates was 1.1 mm. Conclusions: Our results establish the feasibility of inferring primary tumor and nodal motion from anatomical surrogates in 4D CT scans of Stage III lung cancer. Using inferential modeling to decrease the processing time of 4D CT scans may facilitate incorporation of patient-specific treatment margins.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intra and Interfraction Mediastinal Nodal Region Motion: Implications for Internal Target Volume Expansions

The purpose of this study was to determine the intra and interfraction motion of mediastinal lymph node regions. Ten patients with nonsmall-cell lung cancer underwent controlled inhale and exhale computed tomography (CT) scans during two sessions (40 total datasets) and mediastinal nodal stations 1-8 were outlined. Corresponding CT scans from different sessions were registered to remove setup error and, in this reference frame, the centroid of each nodal station was compared for right-left (RL), anterior-posterior (AP), and superior-inferior (SI) displacement. In addition, an anisotropic volume expansion encompassing the change of the nodal region margins in all directions was used. Intrafraction displacement was determined by comparing same session inhale-exhale scans. Interfraction reproducibility of nodal regions was determined by comparing the same respiratory phase scans between two sessions. Intrafraction displacement of centroid varied between nodal stations. All nodal regions moved posteriorly and superiorly with exhalation, and inferior nodal stations showed the most motion. Based on anisotropic expansion, nodal regions expanded mostly in the RL direction from inhale to exhale. The interpatient variations in intrafraction displacement were large compared with the displacements themselves. Moreover, there was substantial interfractional displacement ({approx}5 mm). Mediastinal lymph node regions clearly move during breathing. In addition, deformation of nodal regions between inhale and exhale occurs. The degree of motion and deformation varies by station and by individual. This study indicates the potential advantage of characterizing individualized nodal region motion to safely maximize conformality of mediastinal nodal targets.

61 RADIATION PROTECTION AND DOSIMETRY↗

TU-H-CAMPUS-IeP1-05: A Framework for the Analytic Calculation of Patient-Specific Dose Distribution Due to CBCT Scan for IGRT

Purpose: To investigate the feasibility of an analytic framework to estimate patients’ absorbed dose distribution owing to daily cone-beam CT scan for image-guided radiation treatment. Methods: To compute total absorbed dose distribution, we separated the framework into primary and scattered dose calculations. Using the source parameters such as voltage, current, and bowtie filtration, for the primary dose calculation, we simulated the forward projection from the source to each voxel of an imaging object including some inhomogeneous inserts. Then we calculated the primary absorbed dose at each voxel based on the absorption probability deduced from the HU values and Beer’s law. In sequence, all voxels constructing the phantom were regarded as secondary sources to radiate scattered photons for scattered dose calculation. Details of forward projection were identical to that of the previous step. The secondary source intensities were given by using scatter-to- primary ratios provided by NIST. In addition, we compared the analytically calculated dose distribution with their Monte Carlo simulation results. Results: The suggested framework for absorbed dose estimation successfully provided the primary and secondary dose distributions of the phantom. Moreover, our analytic dose calculations and Monte Carlo calculations were well agreed each other even near the inhomogeneous inserts. Conclusion: This work indicated that our framework can be an effective monitor to estimate a patient’s exposure owing to cone-beam CT scan for image-guided radiation treatment. Therefore, we expected that the patient’s over-exposure during IGRT might be prevented by our framework.

60 APPLIED LIFE SCIENCES↗

Four-Dimensional Computed Tomography Scan Analysis of Tumor and Organ Motion at Varying Levels of Abdominal Compression During Stereotactic Treatment of Lung and Liver

Purpose: To investigate the effectiveness of different abdominal compression levels on tumor and organ motion during stereotactic body radiotherapy of lower lobe lung and liver tumors using four-dimensional (4D)-CT scan analysis. Methods and Materials: Three 4D-CT scans were acquired for 10 patients first using with no compression and then compared with two different levels of abdominal compression. The position of the tumor and various organs were defined at the peak inspiratory and expiratory phases and compared to determine the maximum motion. Results: Mean ({+-}SD) medium compression force (MC) and high compression force (HC) were 47.6 {+-} 16.0 N and 90.7 {+-} 27.1 N, respectively. Mean overall tumor motion was 13.6 mm (2{sigma} [2 sigma] 11.5-15.6), 8.3 mm (2{sigma} 6.0-10.5), and 7.2 mm (2{sigma} 5.4-9.0) for no compression, MC, and HC, respectively. A significant difference in the control of both superior-inferior (SI) and overall motion of tumors was seen with the application of MC and HC when compared with no compression (p < 0.0001 for both). High compression force improved SI and overall tumor motion compared with MC, but this was only significant for SI motion (p = 0.04 and p = 0.06). Significant control of organ motion was only seen in the pancreas (p = 0.01). Conclusions: Four-dimensional CT shows significant control of both lower lobe lung and liver tumors using abdominal compression. High levels of compression improve SI tumor motion when compared with MC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preliminary Studies for a CBCT Imaging Protocol for Offline Organ Motion Analysis: Registration Software Validation and CTDI Measurements

Cone-beam X-ray volumetric imaging in the treatment room, allows online correction of set-up errors and offline assessment of residual set-up errors and organ motion. In this study the registration algorithm of the X-ray volume imaging software (XVI, Elekta, Crawley, United Kingdom), which manages a commercial cone-beam computed tomography (CBCT)-based positioning system, has been tested using a homemade and an anthropomorphic phantom to: (1) assess its performance in detecting known translational and rotational set-up errors and (2) transfer the transformation matrix of its registrations into a commercial treatment planning system (TPS) for offline organ motion analysis. Furthermore, CBCT dose index has been measured for a particular site (prostate: 120 kV, 1028.8 mAs, approximately 640 frames) using a standard Perspex cylindrical body phantom (diameter 32 cm, length 15 cm) and a 10-cm-long pencil ionization chamber. We have found that known displacements were correctly calculated by the registration software to within 1.3 mm and 0.4{sup o}. For the anthropomorphic phantom, only translational displacements have been considered. Both studies have shown errors within the intrinsic uncertainty of our system for translational displacements (estimated as 0.87 mm) and rotational displacements (estimated as 0.22{sup o}). The resulting table translations proposed by the system to correct the displacements were also checked with portal images and found to place the isocenter of the plan on the linac isocenter within an error of 1 mm, which is the dimension of the spherical lead marker inserted at the center of the homemade phantom. The registration matrix translated into the TPS image fusion module correctly reproduced the alignment between planning CT scans and CBCT scans. Finally, measurements on the CBCT dose index indicate that CBCT acquisition delivers less dose than conventional CT scans and electronic portal imaging device portals. The registration software was found to be accurate, and its registration matrix can be easily translated into the TPS and a low dose is delivered to the patient during image acquisition. These results can help in designing imaging protocols for offline evaluations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Use of Three-Dimensional Ultrasound in the Detection of Breast Tumor Bed Displacement During Radiotherapy

Purpose: To evaluate the feasibility and usefulness of a three-dimensional ultrasound (3D-US) image-guided system in identifying and tracking the tumor bed (TB) for planning and daily localization before radiation delivery for breast cancer. Methods and Materials: Twenty breast cancer patients underwent two CT scans at the time of simulation and just before their boost. Three-dimensional ultrasound images were acquired immediately after the CT scans, to which the images were automatically fused. Three-dimensional ultrasound images were also acquired immediately before treatment. Spatial and temporal TB differences between CT and US were evaluated. Results: The TB was not visible on US and CT in 1 subject who had and 1 subject who had not received chemotherapy before whole-breast radiotherapy. The mean (SD) TB volume overlap was 78% (14%). The mean centroid position of the TB on CT vs. US differed by 0.1, 0.2, and 0.4 mm in the anterior-posterior, left-right, and superior-inferior directions. The mean (SD) absolute radial displacement of the TB on each fraction from the treatment plan was 10.8 (6.3) mm. Conclusions: The TB was well visualized by US for the majority of patients. Clinically insignificant differences in the displacements calculated by paired CT vs. paired US demonstrate the feasibility of using 3D-US. The present study suggests that a 10-mm planning target volume margin could result in undercoverage of the clinical target volumes in 50% of treatments. Multimodality planning and image-guided radiotherapy with US potentially offers an accurate and non-ionizing solution for the daily definition of the TB position during partial-breast irradiation and boost treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dataset documenting reaction-induced changes to five fractured foamed wellbore cement cores during CO2 fluid flow

This dataset consists of reconstructed CT scans for four fractured foamed cement cores, generated in the lab using Portland Class H cement, and associated processed data. The cements were exposed to reactive brines, and CT scans were take at different time points through the experiment. The CT imaging allows for the tracking of dissolution-induced changes to fracture morphology, as well as alteration and dissolution in the cement matrix.

Computed Tomography↗

TU-CD-BRA-08: Single-Energy Computed Tomography-Based Pulmonary Perfusion Imaging: Proof-Of-Principle in a Canine Model

Purpose: Pulmonary perfusion imaging has provided significant insights into pulmonary diseases, and can be useful in radiotherapy. The purpose of this study was to prospectively establish proof-of-principle in a canine model for single-energy CT-based perfusion imaging, which has the potential for widespread clinical implementation. Methods: Single-energy CT perfusion imaging is based on: (1) acquisition of inspiratory breath-hold CT scans before and after intravenous injection of iodinated contrast medium, (2) deformable image registration (DIR) of the two CT image data sets, and (3) subtraction of the pre-contrast image from post-contrast image, yielding a map of Hounsfield unit (HU) enhancement. These subtraction image data sets hypothetically represent perfused blood volume, a surrogate for perfusion. In an IACUC-approved clinical trial, we acquired pre- and post-contrast CT scans in the prone posture for six anesthetized, mechanically-ventilated dogs. The elastix algorithm was used for DIR. The registration accuracy was quantified using the target registration errors (TREs) for 50 pulmonary landmarks in each dog. The gradient of HU enhancement between gravity-dependent (ventral) and non-dependent (dorsal) regions was evaluated to quantify the known effect of gravity, i.e., greater perfusion in ventral regions. Results: The lung volume difference between the two scans was 4.3±3.5% on average (range 0.3%–10.1%). DIR demonstrated an average TRE of 0.7±1.0 mm. HU enhancement in lung parenchyma was 34±10 HU on average and varied considerably between individual dogs, indicating the need for improvement of the contrast injection protocol. HU enhancement in ventral (gravity-dependent) regions was found to be greater than in dorsal regions. A population average ventral-to-dorsal gradient of HU enhancement was strong (R{sup 2}=0.94) and statistically significant (p<0.01). Conclusion: This canine study demonstrated relatively accurate DIR and a strong ventral-to-dorsal gradient of HU enhancement, providing proof-of-principle for single-energy CT pulmonary perfusion imaging. This ongoing study will enroll more dogs and investigate the physiological significance. This study was supported by a Philips Healthcare/Radiological Society of North America (RSNA) Research Seed Grant (RSD1458)

60 APPLIED LIFE SCIENCES↗

Reducing radiation dose to selected organs by selecting the tube start angle in MDCT helical scans: A Monte Carlo based study

Purpose: Previous work has demonstrated that there are significant dose variations with a sinusoidal pattern on the peripheral of a CTDI 32 cm phantom or on the surface of an anthropomorphic phantom when helical CT scanning is performed, resulting in the creation of ''hot'' spots or ''cold'' spots. The purpose of this work was to perform preliminary investigations into the feasibility of exploiting these variations to reduce dose to selected radiosensitive organs solely by varying the tube start angle in CT scans. Methods: Radiation dose to several radiosensitive organs (including breasts, thyroid, uterus, gonads, and eye lenses) resulting from MDCT scans were estimated using Monte Carlo simulation methods on voxelized patient models, including GSF's Baby, Child, and Irene. Dose to fetus was also estimated using four pregnant female models based on CT images of the pregnant patients. Whole-body scans were simulated using 120 kVp, 300 mAs, both 28.8 and 40 mm nominal collimations, and pitch values of 1.5, 1.0, and 0.75 under a wide range of start angles (0 deg. - 340 deg. in 20 deg. increments). The relationship between tube start angle and organ dose was examined for each organ, and the potential dose reduction was calculated. Results: Some organs exhibit a strong dose variation, depending on the tube start angle. For small peripheral organs (e.g., the eye lenses of the Baby phantom at pitch 1.5 with 40 mm collimation), the minimum dose can be 41% lower than the maximum dose, depending on the tube start angle. In general, larger dose reductions occur for smaller peripheral organs in smaller patients when wider collimation is used. Pitch 1.5 and pitch 0.75 have different mechanisms of dose reduction. For pitch 1.5 scans, the dose is usually lowest when the tube start angle is such that the x-ray tube is posterior to the patient when it passes the longitudinal location of the organ. For pitch 0.75 scans, the dose is lowest when the tube start angle is such that the x-ray tube is anterior to the patient when it passes the longitudinal location of the organ. Conclusions: Helical MDCT scanning at pitch 1.5 and pitch 0.75 results in ''cold spots'' and ''hot spots'' that are created both at surface and in-depth locations within patients. For organs that have a relatively small longitudinal extent, dose can vary considerably with different start angles. While current MDCT systems do not provide the user with the ability to control the tube start angle, these results indicate that in these specific situations (pitch 1.5 or pitch 0.75, small organs and especially small patients), there could be significant dose savings to organs if that functionality would be provided.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-92: Clinical Benefit for Breast and Chest Wall Setup in Using a Breast Board

Purpose: To validate benefit of using a breast board (BB) by analyzing the geometry and dosimetry changes of the regions of interest (ROIs) between CT scans with and without BB. Methods: Seven patients, two chest walls (CW) and five breasts, use BB at CT simulation and no BB at diagnostic CT were included. By using deformable image registration software (Velocity AI), diagnostic CT and planning CT were rigidly co-registered according to the thoracic cage at the target. The heart and the target were then deformedly matched and the contours of the planned ROIs were transferred to the diagnostic CT. Which were brought back to the planning CT data set though the initial rigid co-registration in order to keep the deformed ROIs redefined in the diagnostic CT. Anatomic shifts and volume changes of a ROI beyond the rigid translation were recorded and dosimetry changes to ROIs were compared with recalculated DVHs. Results: Patient setup without the BB had small but systematic heart shifts superiorly by ∼5 mm. Torso rotations in two cases moved the heart in opposite directions by ∼10 mm. The breast target volume, shape, and locations were significantly changed with arm extension over the head but not in cases with the arm extended laterally. Breast setup without BB could increase the mean dose to the heart and the maximal dose to the anterior ventricle wall by 1.1 and 6.7 Gy, respectively. Conclusion: A method for evaluation of breast setup technique is introduced and applied for patients. Results of systematic heart displacement without using the BB and the potential increase of heart doses encourage us to further investigate the current trend of not using a BB for easy setup and CT scans. Using a BB would likely increase patient sag during prolonged IMRT and real-time patient position monitoring is clinically desired.

60 APPLIED LIFE SCIENCES↗

Effect of CT contrast on volumetric arc therapy planning (RapidArc and helical tomotherapy) for head and neck cancer

The objectives of the study were to evaluate the effect of intravenous contrast in the dosimetry of helical tomotherapy and RapidArc treatment for head and neck cancer and determine if it is acceptable during the computed tomography (CT) simulation to acquire only CT with contrast for treatment planning of head and neck cancer. Overall, 5 patients with head and neck cancer (4 men and 1 woman) treated on helical tomotherapy were analyzed retrospectively. For each patient, 2 consecutive CT scans were performed. The first CT set was scanned before the contrast injection and secondary study set was scanned 45 seconds after contrast. The 2 CTs were autoregistered using the same Digital Imaging and Communications in Medicine coordinates. Tomotherapy and RapidArc plans were generated on 1 CT data set and subsequently copied to the second CT set. Dose calculation was performed, and dose difference was analyzed to evaluate the influence of intravenous contrast media. The dose matrix used for comparison included mean, minimum and maximum doses of planning target volume (PTV), PTV dose coverage, and V{sub 45} {sub Gy}, V{sub 30} {sub Gy}, and V{sub 20} {sub Gy} organ doses. Treatment planning on contrasted images generally showed a lower dose to both organs and target than plans on noncontrasted images. The doses for the points of interest placed in the organs and target rarely changed more than 2% in any patient. In conclusion, treatment planning using a contrasted image had insignificant effect on the dose to the organs and targets. In our opinion, only CT with contrast needs to be acquired during the CT simulation for head and neck cancer. Dose calculations performed on contrasted images can potentially underestimate the delivery dose slightly. However, the errors of planning on a contrasted image should not affect the result in clinically significant way.

61 RADIATION PROTECTION AND DOSIMETRY↗