The Detectability and Localization Accuracy of Implanted Fiducial Markers Determined on In-Room Computerized Tomography (CT) and Electronic Portal Images (EPI)

Many different methods of image guidance are available for radiotherapy treatment (IGRT). The aims of the study were (1) to determine the optimal diameter of gold markers for IGRT to the prostate; (2) to compare, using the Siemens Primatom, the relative merits of in-room computerized tomography (CT) and electronic portal image (EPI) for locating the marker seeds. Gold markers of differing widths were embedded in 2 phantoms (perspex slabs and anthropomorphic). Images were acquired with an amorphous silicon flat panel detector (Siemens Optivue 500) and with the in-room CT scanner (Siemens Somatom Balance). The EPIs were reviewed independently by 6 operators to determine which diameter marker could be best visualized. The optimal marker technique was determined by comparing the investigators' observed marker co-ordinates with the known locations within the phantom. The visibility of all markers on anterior-posterior EPIs was 100%. On the lateral EPI, of a possible 180 visualizations of 1.2-, 1.0-, and 0.8-mm diameter markers, 176 (97.8%), 151 (83.9%), and 132 (73.3%), respectively, were successful. On EPI, the average deviation of fiducial markers from the known position was less than 0.5 mm in any direction. On CT, the largest deviation (2.17 mm) of markers from the known coordinate position was in the superior-inferior direction, reflecting the 3.0-mm slice thickness used. EPI accurately located internal markers in all dimensions. The availability of 'gold standard' CT imagery at the treatment unit does not improve how accurately the position of markers in a phantom can be defined compared with EPI. However, CT imagery does provide important soft tissue information, the benefits of which are being investigated further.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-F-CAMPUS-I-02: Validation of a CT X-Ray Source Characterization Technique for Dose Computation Using An Anthropomorphic Thorax Phantom

Purpose: To experimentally validate a rotational kV x-ray source characterization technique by computing CT dose in an anthropomorphic thorax phantom using an in-house dose computation algorithm (kVDoseCalc). Methods: The lateral variation in incident energy spectra of a GE Optima big bore CT scanner was found by measuring the HVL along the internal, full bow-tie filter axis. The HVL and kVp were used to generate the x-ray spectra using Spektr software, while beam fluence was derived by dividing the integral product of the spectra and in-air mass-energy absorption coefficients by in-air dose measurements along the bow-tie filter axis. Beams produced by the GE Optima scanner were modeled at 80 and 140 kVp tube settings. kVDoseCalc calculates dose by solving the linear Boltzmann transport equation using a combination of deterministic and stochastic methods. Relative doses in an anthropomorphic thorax phantom (E2E SBRT Phantom) irradiated by the GE Optima scanner were measured using a (0.015 cc) PTW Freiburg ionization chamber, and compared to computations from kVDoseCalc. Results: The agreement in relative dose between dose computation and measurement for points of interest (POIs) within the primary path of the beam was within experimental uncertainty for both energies, however points outside the primary beam were not. The average absolute percent difference for POIs within the primary path of the beam was 1.37% and 5.16% for 80 and 140 kVp, respectively. The minimum and maximum absolute percent difference for both energies and all POIs within the primary path of the beam was 0.151% and 6.41%, respectively. Conclusion: The CT x-ray source characterization technique based on HVL measurements and kVp can be used to accurately compute CT dose in an anthropomorphic thorax phantom.

60 APPLIED LIFE SCIENCES↗

Quantitative Assessment of Image-Guided Radiotherapy for Paraspinal Tumors

Purpose: To evaluate stereotactic positioning uncertainties of patients with paraspinal tumors treated with fractionated intensity-modulated radiotherapy; and to determine whether target-point correction via rigid registration is sufficient for daily patient positioning. Patients and Methods: Forty-five patients with tumors at the cervical, thoracic, and lumbar spine received regular control computed-tomography (CT) scans using an in-room CT scanner. All patients were immobilized with the combination of Scotch cast torso and head masks. The positioning was evaluated regarding translational and rotational errors by applying a rigid registration algorithm based on mutual information. The registration box was fitted to the target volume for optimal registration in the high-dose area. To evaluate the suitability of the rigid registration result for correcting the target volume position we subsequently registered three small subsections of the upper, middle, and lower target volume. The resulting residual deviations reflect the extent of the elastic deformations, which cannot be covered by the rigid-body registration procedure. Results: A total of 321 control CT scans were evaluated. The rotational errors were negligible. Translational errors were smallest for cervical tumors (-0.1 +- 1.1, 0.3 +- 0.8, and 0.1 +- 0.9 mm along left-right, anterior-posterior, and superior-inferior axes), followed by thoracic (0.8 +- 1.1, 0.3 +- 0.8, and 1.1 +- 1.3 mm) and lumbar tumors (-0.7 +- 1.3, 0.0 +- 0.9, and 0.5 +- 1.6 mm). The residual deviations of the three subsections were <1 mm. Conclusions: The applied stereotactic patient setup resulted in small rotational errors. However, considerable translational positioning errors may occur; thus, on the basis of these data daily control CT scans are recommended. Rigid transformation is adequate for correcting the target volume position.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A rapid noninvasive characterization of CT x-ray sources

Purpose: The aim of this study is to generate spatially varying half value layers (HVLs) that can be used to construct virtual equivalent source models of computed tomography (CT) x-ray sources for use in Monte Carlo CT dose computations. Methods: To measure the spatially varying HVLs, the authors combined a cylindrical HVL measurement technique with the characterization of bowtie filter relative attenuation (COBRA) geometry. An apparatus given the name “HVL Jig” was fabricated to accurately position a real-time dosimeter off-isocenter while surrounded by concentric cylindrical aluminum filters (CAFs). In this geometry, each projection of the rotating x-ray tube is filtered by an identical amount of high-purity (type 1100 H-14) aluminum while the stationary radiation dose probe records an air kerma rate versus time waveform. The CAFs were progressively nested to acquire exposure data at increasing filtrations to calculate the HVL. Using this dose waveform and known setup geometry, each timestamp was related to its corresponding fan angle. Data were acquired using axial CT protocols (i.e., rotating tube and stationary patient table) at energies of 80, 100, and 120 kVp on a single CT scanner. These measurements were validated against the more laborious conventional step-and-shoot approach (stationary x-ray tube). Results: At each energy, HVL data points from the COBRA-cylinder technique were fit to a trendline and compared with the conventional approach. The average relative difference in HVL between the two techniques was 1.3%. There was a systematic overestimation in HVL due to scatter contamination. Conclusions: The described method is a novel, rapid, accurate, and noninvasive approach that allows one to acquire the spatially varying fluence and HVL data using a single experimental setup in a minimum of three scans. These measurements can be used to characterize the CT beam in terms of the angle-dependent fluence and energy spectra along the bowtie filter direction, which can serve as input for accurate CT dose computations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-I-86: Evaluation of the New RaySafe Unfors X2 Dosimetry System

Purpose: To evaluate the new RaySafe Unfors X2 (X2) dosimetry system and compare it to the operation of the RaySafe Unfors Xi (Xi) and Radcal Accugold (RCAG) dosimetry systems. The comparison was done for the radiographic/fluoroscopic detectors, mammography detectors and the CT ionization chambers. Methods: This study used several R/F rooms, GE AMX4 portable x-ray unit, Siemens Biograph 16 slice CT scanner and a Hologic Dimensions mammography unit to evaluate the dosimetry systems. The three X2 detectors were compared to similar detectors of the older Xi and RCAG detectors under clinical conditions used for diagnostic medical physics testing. Measurements of kVp, HVL and exposure were made under identical conditions. Results: For radiography and fluoroscopy the three systems agreed to within +2 kVp in the 60 to 140 kVp range, HVL measurements agreed to within +2 mm Al and the exposures agreed to within +5%. The RCAG 6 cc ionization chamber measured at least 3% higher than the diode systems. The X2 R/F detector appeared to be transparent to the fluoroscopy AEC system. For exposures made using both the CT ACR dose phantoms, the X2 agreed to within +3% of the other two systems. For mammography measurements, the three systems agreed to within +0.4kVp (25-49 kVp range), HVL measurements agreed to within +0.05 mm Al and the exposures agreed to within +1% of the ionization chamber. Conclusion: The X2 system is a new version of the older Xi system. The system is faster, more robust, very easy to use, has a larger dynamic range, produced less errors and stores 1000 exposures. The measurements showed that the system performs well in the clinical environment and the X2 is within + 5% agreement of the other two calibrated systems.

60 APPLIED LIFE SCIENCES↗

MO-E-17A-09: Has Cancer Risk for Pediatric CT Increased Or Decreased? An Analysis of Cohort Data From 2004-2013

Purpose: To analyze CT radiation dosimetry trends in a pediatric population imaged with modern (2004-2013) CT technology Methods: The institutional review board approved this retrospective review. Two cohorts of pediatric patients that received CT scans for treatment or surveillance for Wilms tumor (n=73) or Neuroblastoma (n=74) from 2004–2013 were included in this study. Patients were scanned during this time period on a GE Ultra (8 slice; 2004–2007), a GE VCT (2008–2011), or a GE VCT-XTe (2011–2013). Each patient's individual or combined chest, abdomen, and pelvic CT exams (n=4138) were loaded onto a PACS workstation (Intelerad, Canada) and measured to calculate their effective diameter and SSDE. Patient SSDE was used to estimate patient organ dosimetry based on previously published data. Patient's organ dosimetry were sorted by gender, weight, age, scan protocol (i.e., chest, abdomen, or pelvis), and CT scanner technology and averaged accordingly to calculate population averaged absolute and effective dose values. Results: Patient radiation dose burden calculated for all genders, weights, and ages decreased at a rate of 0.2 mSv/year (4.2 mGy/year; average organ dose) from 2004–2013; overall levels decreased by 50% from 3.0 mSv (60.0 mGy) to 1.5 mSv (25.9 mGy). Patient dose decreased at equal rates for both male and female, and for individual scan protocols. The greatest dose savings was found for patients between 0–4 years old (65%) followed by 5-9 years old (45%), 10–14 years old (30%), and > 14 years old (21%). Conclusion: Assuming a linear-nothreshold model, there always will be potential risk of cancer induction from CT. However, as demonstrated among these patient populations, effective and organ dose has decreased over the last decade; thus, potential risk of long-term side effects from pediatric CT examinations has also been reduced.

60 APPLIED LIFE SCIENCES↗

TH-E-17A-10: Markerless Lung Tumor Tracking Based On Beams Eye View EPID Images

Purpose: Dynamic tumor tracking or motion compensation techniques have proposed to modify beam delivery following lung tumor motion on the flight. Conventional treatment plan QA could be performed in advance since every delivery may be different. Markerless lung tumor tracking using beams eye view EPID images provides a best treatment evaluation mechanism. The purpose of this study is to improve the accuracy of the online markerless lung tumor motion tracking method. Methods: The lung tumor could be located on every frame of MV images during radiation therapy treatment by comparing with corresponding digitally reconstructed radiograph (DRR). A kV-MV CT corresponding curve is applied on planning kV CT to generate MV CT images for patients in order to enhance the similarity between DRRs and MV treatment images. This kV-MV CT corresponding curve was obtained by scanning a same CT electron density phantom by a kV CT scanner and MV scanner (Tomotherapy) or MV CBCT. Two sets of MV DRRs were then generated for tumor and anatomy without tumor as the references to tracking the tumor on beams eye view EPID images. Results: Phantom studies were performed on a Varian TrueBeam linac. MV treatment images were acquired continuously during each treatment beam delivery at 12 gantry angles by iTools. Markerless tumor tracking was applied with DRRs generated from simulated MVCT. Tumors were tracked on every frame of images and compared with expected positions based on programed phantom motion. It was found that the average tracking error were 2.3 mm. Conclusion: This algorithm is capable of detecting lung tumors at complicated environment without implanting markers. It should be noted that the CT data has a slice thickness of 3 mm. This shows the statistical accuracy is better than the spatial accuracy. This project has been supported by a Varian Research Grant.

60 APPLIED LIFE SCIENCES↗

SU-E-I-34: Evaluating Use of AEC to Lower Dose for Lung Cancer Screening CT Protocols

Purpose: The National Lung Screening Trial mandated manual low dose CT technique factors, where up to a doubling of radiation output could be used over a regular to large patient size range. Recent guidance from the AAPM and ACR for lung cancer CT screening recommends radiation output adjustment for patient size either through AEC or a manual technique chart. This study evaluated the use of AEC for output control and dose reduction. Methods: The study was performed on a multidetector helical CT scanner (Aquillion ONE, Toshiba Medical) equipped with iterative reconstruction (ADIR-3D), AEC was adjusted with a standard deviation (SD) image quality noise index. The protocol SD parameter was incrementally increased to reduce patient population dose while image quality was evaluated by radiologist readers scoring the clinical utility of images on a Likert scale. Results: Plots of effective dose vs. body size (water cylinder diameter reported by the scanner) demonstrate monotonic increase in patient dose with increasing patient size. At the initial SD setting of 19 the average CTDIvol for a standard size patient was ∼ 2.0 mGy (1.2 mSv effective dose). This was reduced to ∼1.0 mGy (0.5 mSv) at an SD of 25 with no noticeable reduction in clinical utility of images as demonstrated by Likert scoring. Plots of effective patient diameter and BMI vs body size indicate that these metrics could also be used for manual technique charts. Conclusion: AEC offered consistent and reliable control of radiation output in this study. Dose for a standard size patient was reduced to one-third of the 3 mGy CTDIvol limit required for ACR accreditation of lung cancer CT screening. Gary Arbique: Research Grant, Toshiba America Medical Systems; Cecelia Brewington: Research Grant, Toshiba America Medical Systems; Di Zhang: Employee, Toshiba America Medical Systems.

60 APPLIED LIFE SCIENCES↗

SU-C-201-02: Dosimetric Verification of SBRT with FFF-VMAT Using a 3-D Radiochromic/Optical-CT Dosimetry System

Purpose: With an increasing use of small field size and high dose rate irradiation in the advances of radiotherapy techniques, such as stereotactic body radiotherapy (SBRT) and stereotactic radiosurgery (SRS), an in-depth quality assurance (QA) system is required. The purpose of this study is to investigate a high resolution optical CT-based 3D radiochromic dosimetry system for SBRT with intensity modulated radiotherapy (IMRT) and flattening filter free (FFF) volumetric modulated arc therapy (VMAT). Methods: Cylindrical PRESAGE radiochromic dosimeters of 10cm height and 11cm diameter were used to validate SBRT. Four external landmarks were placed on the surface of each dosimeter to define the isocenter of target. SBRT plans were delivered using a Varian TrueBeam™ linear accelerator (LINAC). Three validation plans, SBRT with IMRT (6MV 600MU/min), FFF-VMAT (10MV 2400MU/min), and mixed FFF-VMAT (6MV 1400MU/min, 10MV 2400MU/min), were delivered to the PRESAGE dosimeters. Each irradiated PRESAGE dosimeter was scanned using a single laser beam optical CT scanner and reconstructed with a 1mm × 1mm high spatial resolution. The comparison of measured dose distributions of irradiated PRESAGE dosimeters to those calculated by Pinnacle{sup 3} treatment planning system (TPS) were performed with a 10% dose threshold, 3% dose difference (DD), and 3mm distance-to-agreement (DTA) Gamma criteria. Results: The average pass rates for the gamma comparisons between PRESAGE and Pinnacle{sup 3} in the transverse, sagittal, coronal planes were 94.6%, 95.9%, and 96.4% for SBRT with IMRT, FFF-VMAT, and mixed FFF-VMAT plans, respectively. A good agreement of the isodose distributions of those comparisons were shown at the isodose lines 50%, 70%, 80%, 90% and 98%. Conclusion: This study demonstrates the feasibility of the high resolution optical CT-based 3D radiochromic dosimetry system for validation of SBRT with IMRT and FFF-VMAT. This dosimetry system offers higher precision QA with 3D dose information for small beams compared to what is currently available.

60 APPLIED LIFE SCIENCES↗

SU-F-T-626: Intracranial SRS Re-Treatment Without Acquisition of New CT Images

Purpose: Linear accelerator based stereotactic radiosurgery (SRS) for multiple intracranial lesions with frequent surveillance is becoming a popular treatment option. This strategy leads to retreatment with SRS as new lesions arise. Currently, each course of treatment uses magnetic resonance (MR) and computed tomography (CT) images for treatment planning. We propose that new MR images, with course 1 CT images, may be used for future treatment plans with negligible loss of dosimetric accuracy. Methods: Ten patients that received multiple courses of SRS were retrospectively reviewed. The treatment plans and contours from non-initial courses were copied to the initial CTs and recalculated. Doses metrics for the plans calculated on the initial CTs and later CTs were compared. All CT scans were acquired on a Philips CT scanner with a 600 mm field of view and 1 mm slice thickness (Philips Healthcare, Andover, MA). All targets were planned to 20 Gy and calculated in Eclipse V. 13.6 (Varian, Palo Alto, CA) using analytic anisotropic algorithm with 1 mm calculation grid. Results: Sixteen lesions were evaluated. The mean time between courses was 250 +/− 215 days (range 103–979). The mean target volume was 2.0 +/− 2.9 cc (range 0.1–10.1). The average difference in mean target dose between the two calculations was 0.2 +/− 0.3 Gy (range 0.0 – 1.0). The mean conformity index (CI) was 1.28 +/− 0.14 (range 1.07 – 1.82). The average difference in CI was 0.03 +/− 0.16 (range 0.00 – 0.44). Targets volumes < 0.5 cc showed the largest changes in both metrics. Conclusion: Continued treatment based on initial CT images is feasible. Dose calculation on the initial CT for future treatments provides reasonable dosimetric accuracy. Changes in dose metrics are largest for small volumes, and are likely dominated by partial volume effects in target definition.

60 APPLIED LIFE SCIENCES↗

Changes realized from extended bit-depth and metal artifact reduction in CT

Purpose: High-Z material in computed tomography (CT) yields metal artifacts that degrade image quality and may cause substantial errors in dose calculation. This study couples a metal artifact reduction (MAR) algorithm with enhanced 16-bit depth (vs standard 12-bit) to quantify potential gains in image quality and dosimetry. Methods: Extended CT to electron density (CT-ED) curves were derived from a tissue characterization phantom with titanium and stainless steel inserts scanned at 90-140 kVp for 12- and 16-bit reconstructions. MAR was applied to sinogram data (Brilliance BigBore CT scanner, Philips Healthcare, v.3.5). Monte Carlo simulation (MC-SIM) was performed on a simulated double hip prostheses case (Cerrobend rods embedded in a pelvic phantom) using BEAMnrc/Dosxyz (400 000 0000 histories, 6X, 10 Multiplication-Sign 10 cm{sup 2} beam traversing Cerrobend rod). A phantom study was also conducted using a stainless steel rod embedded in solid water, and dosimetric verification was performed with Gafchromic film analysis (absolute difference and gamma analysis, 2% dose and 2 mm distance to agreement) for plans calculated with Anisotropic Analytic Algorithm (AAA, Eclipse v11.0) to elucidate changes between 12- and 16-bit data. Three patients (bony metastases to the femur and humerus, and a prostate cancer case) with metal implants were reconstructed using both bit depths, with dose calculated using AAA and derived CT-ED curves. Planar dose distributions were assessed via matrix analyses and using gamma criteria of 2%/2 mm. Results: For 12-bit images, CT numbers for titanium and stainless steel saturated at 3071 Hounsfield units (HU), whereas for 16-bit depth, mean CT numbers were much larger (e.g., titanium and stainless steel yielded HU of 8066.5 {+-} 56.6 and 13 588.5 {+-} 198.8 for 16-bit uncorrected scans at 120 kVp, respectively). MC-SIM was well-matched between 12- and 16-bit images except downstream of the Cerrobend rod, where 16-bit dose was {approx}6.4% greater than 12-bit. Absolute film dosimetry in a region downstream of a stainless steel rod revealed that 16-bit calculated dose, with and without MAR, agreed more closely with film results (1%-2% less than film) as compared to 12-bit reconstructions (5.6%-6.5% less than film measurements). Gamma analysis revealed that 16-bit dose calculations were better matched to film results than 12-bit ({approx}10% higher pass rates for 16-bit). Similar results were observed in two patient cases; the largest discrepancy was observed for a femur case where 12-bit doses, both with and without MAR correction, were 6-7 Gy lower ({approx}17%-20% of the prescription dose) as compared to 16-bit dose calculations. However, when beams are not directly traversing metal, such as a prostate cancer case with bilateral hip prostheses; the impact of 16-bit reconstruction was diminished. Conclusions: These results suggest that it may be desirable to implement 16-bit MAR-corrected images for treatment planning purposes, which can provide a more accurate dosimetric approach coupled with improved visualization by suppression of CT artifacts.

61 RADIATION PROTECTION AND DOSIMETRY↗

Sci—Fri PM: Dosimetry—01: Radiation-induced refraction artefacts in the optical CT readout of polymer gel dosimeters

Polymer gel dosimeters (PGDs) are a desirable tool for the verification of advanced radiotherapy treatments. Fully 3D, deformable, and tissue-equivalent, the PGD polymerizes wherever it absorbs dose. To measure the dose absorbed by a PGD, optical computed tomography (CT) can be used to evaluate, in full 3D, the opacity distribution that coincides with polymerization. In addition to an increase in opacity with dose, an increase in refractive index (RI) is also known to occur in irradiated polymer gels. The increase in RI is slight and was previously assumed insignificant. This work reveals the effects that radiation-induced RI changes can have on the optical CT readout of PGDs. A fan-beam optical CT scanner was used to image a cylindrical PGD irradiated by a pair of 3×3 cm{sup 2}, 6 MV photon beams in an orthogonal arrangement. Investigative scans were performed to evaluate refraction errors occurring: i) within the plane, and ii) out of the plane of the fan-beam. In-plane refraction was shown to cause distinct streaking artefacts along dose gradients (i.e. RI gradients) due to higher intensity rays being refracted into more opaque regions. Out-of-plane refraction was shown to produce severe, widespread artefacts due to rays missing the detector array. An iterative Savitzky-Golay filtering technique was developed to reduce both types of artefacts by specifically targeting structured errors in sinogram space. Results introduce a new category of imaging artefacts to be aware of when using optical CT for PGD readout.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-G-IeP2-09: Iodine Imaging at Spectral CT with a Dual-Layer Detector

Purpose: To evaluate the attenuation response of iodine and the accuracy of iodine quantification on a detector-based spectral CT scanner. Methods: A Gammex 461A phantom was scanned using a dual-layer detector (IQon, Philips) at 120 kVp using helical acquisition with a CDTIvol of 15 mGy to approximate the hospital’s clinical body protocol. No modifications to the standard protocol were necessary to enable spectral imaging. Iodine inserts at 6 concentrations (2, 5, 7.5, 10, 15, 20 mg/ml) were scanned individually at the center of the phantom and the 20 mg/ml insert was additionally scanned at the 3, 6, and 12 o’clock positions. Scans were repeated 10 times. Conventional, virtual monoenergetic (40–200 keV) and iodine-no-water images (with pixel values equal to iodine concentration of corresponding tissue) were reconstructed from acquired data. A circular ROI (diameter=30 pixels) was used in each conventional and monoenergetic image to measure the mean and standard deviation of the CT number in HU and in each iodine-no-water image to measure iodine concentration in mg/ml. Results: Mean CT number and contrast-to-noise ratio (CNR) measured from monoenergetic images increased with decreasing keV for all iodine concentrations and matched measurements from conventional images at 75 keV. Measurements from the 20 ml insert showed the CT number is independent of location and CNR is a function only of noise, which was higher in the center. Measured concentration from iodine-no-water images matched phantom manufacturer suggested concentration to within 6% on average for inserts at the center of the phantom. Measured concentrations were systematically higher due to optimization of iodine quantification parameters for clinical mixtures of iodine and blood/tissue. Conclusion: Spectral acquisition and reconstruction with a dual-layer detector represents the physical behavior of iodine as expected and accurately quantifies the material concentration. This should permit a variety of clinical applications including lesion characterization, vessel patency, and myocardial perfusion. This study was performed as part of a research agreement among Philips Healthcare, University Hospitals of Cleveland, and Case Western Reserve University.

60 APPLIED LIFE SCIENCES↗

On the feasibility of comprehensive high-resolution 3D remote dosimetry

Purpose: This study investigates the feasibility of remote high-resolution 3D dosimetry with the PRESAGE®/Optical-CT system. In remote dosimetry, dosimeters are shipped out from a central base institution to a remote institution for irradiation, then shipped back to the base institution for subsequent readout and analysis. Methods: Two nominally identical optical-CT scanners for 3D dosimetry were constructed and placed at the base (Duke University) and remote (Radiological Physics Center) institutions. Two formulations of PRESAGE® (SS1, SS2) radiochromic dosimeters were investigated. Higher sensitivity was expected in SS1, which had higher initiator content (0.25% bromotrichloromethane), while greater temporal stability was expected in SS2. Four unirradiated PRESAGE® dosimeters (two per formulation, cylindrical dimensions 11 cm diameter, 8.5–9.5 cm length) were imaged at the base institution, then shipped to the remote institution for planning and irradiation. Each dosimeter was irradiated with the same simple treatment plan: an isocentric 3-field “cross” arrangement of 4 × 4 cm open 6 MV beams configured as parallel opposed laterals with an anterior beam. This simple plan was amenable to accurate and repeatable setup, as well as accurate dose modeling by a commissioned treatment planning system (Pinnacle). After irradiation and subsequent (within 1 h) optical-CT readout at the remote institution, the dosimeters were shipped back to the base institution for remote dosimetry readout 3 days postirradiation. Measured on-site and remote relative 3D dose distributions were registered to the Pinnacle dose calculation, which served as the reference distribution for 3D gamma calculations with passing criteria of 5%/2 mm, 3%/3 mm, and 3%/2 mm with a 10% dose threshold. Gamma passing rates, dose profiles, and color-maps were all used to assess and compare the performance of both PRESAGE® formulations for remote dosimetry. Results: The best agreements between the Pinnacle plan and dosimeter readout were observed in PRESAGE® formulation SS2. Under 3%/3 mm 3D gamma passing criteria, passing rates were 91.5% ± 3.6% (SS1) and 97.4% ± 2.2% (SS2) for immediate on-site dosimetry, 96.7% ± 2.4% (SS1) and 97.6% ± 0.6% (SS2) for remote dosimetry. These passing rates are well within TG119 recommendations (88%–90% passing). Under the more stringent criteria of 3%/2 mm, there is a pronounced difference [8.0 percentage points (pp)] between SS1 formulation passing rates for immediate and remote dosimetry while the SS2 formulation maintains both higher passing rates and consistency between immediate and remote results (differences ≤ 1.2 pp) at all metrics. Both PRESAGE® formulations under study maintained high linearity of dose response (R{sup 2} > 0.996) for 1–8 Gy over 14 days with response slope consistency within 4.9% (SS1) and 6.6% (SS2), and a relative dose distribution that remained stable over time was demonstrated in the SS2 dosimeters. Conclusions: Remote 3D dosimetry was shown to be feasible with a PRESAGE® dosimeter formulation (SS2) that exhibited relative temporal stability and high accuracy when read off-site 3 days postirradiation. Characterization of the SS2 dose response demonstrated linearity (R{sup 2} > 0.998) over 14 days and suggests accurate readout over longer periods of time would be possible. This result provides a foundation for future investigations using remote dosimetry to study the accuracy of advanced radiation treatments. Further work is planned to characterize dosimeter reproducibility and dose response over longer periods of time.

60 APPLIED LIFE SCIENCES↗

SU-E-I-82: Improving CT Image Quality for Radiation Therapy Using Iterative Reconstruction Algorithms and Slightly Increasing Imaging Doses

Purpose: Iterative reconstruction (IR) algorithms are developed to improve CT image quality (IQ) by reducing noise without diminishing spatial resolution or contrast. For CT in radiation therapy (RT), slightly increasing imaging dose to improve IQ may be justified if it can substantially enhance structure delineation. The purpose of this study is to investigate and to quantify the IQ enhancement as a result of increasing imaging doses and using IR algorithms. Methods: CT images were acquired for phantoms, built to evaluate IQ metrics including spatial resolution, contrast and noise, with a variety of imaging protocols using a CT scanner (Definition AS Open, Siemens) installed inside a Linac room. Representative patients were scanned once the protocols were optimized. Both phantom and patient scans were reconstructed using the Sinogram Affirmed Iterative Reconstruction (SAFIRE) and the Filtered Back Projection (FBP) methods. IQ metrics of the obtained CTs were compared. Results: IR techniques are demonstrated to preserve spatial resolution as measured by the point spread function and reduce noise in comparison to traditional FBP. Driven by the reduction in noise, the contrast to noise ratio is doubled by adopting the highest SAFIRE strength. As expected, increasing imaging dose reduces noise for both SAFIRE and FBP reconstructions. The contrast to noise increases from 3 to 5 by increasing the dose by a factor of 4. Similar IQ improvement was observed on the CTs for selected patients with pancreas and prostrate cancers. Conclusion: The IR techniques produce a measurable enhancement to CT IQ by reducing the noise. Increasing imaging dose further reduces noise independent of the IR techniques. The improved CT enables more accurate delineation of tumors and/or organs at risk during RT planning and delivery guidance.

60 APPLIED LIFE SCIENCES↗

Development of a method to estimate organ doses for pediatric CT examinations

Purpose: To develop a method for estimating doses to primarily exposed organs in pediatric CT by taking into account patient size and automatic tube current modulation (ATCM). Methods: A Monte Carlo CT dosimetry software package, which creates patient-specific voxelized phantoms, accurately simulates CT exposures, and generates dose images depicting the energy imparted on the exposed volume, was used. Routine head, thorax, and abdomen/pelvis CT examinations in 92 pediatric patients, ranging from 1-month to 14-yr-old (49 boys and 43 girls), were simulated on a 64-slice CT scanner. Two sets of simulations were performed in each patient using (i) a fixed tube current (FTC) value over the entire examination length and (ii) the ATCM profile extracted from the DICOM header of the reconstructed images. Normalized to CTDI{sub vol} organ dose was derived for all primary irradiated radiosensitive organs. Normalized dose data were correlated to patient’s water equivalent diameter using log-transformed linear regression analysis. Results: The maximum percent difference in normalized organ dose between FTC and ATCM acquisitions was 10% for eyes in head, 26% for thymus in thorax, and 76% for kidneys in abdomen/pelvis. In most of the organs, the correlation between dose and water equivalent diameter was significantly improved in ATCM compared to FTC acquisitions (P < 0.001). Conclusions: The proposed method employs size specific CTDI{sub vol}-normalized organ dose coefficients for ATCM-activated and FTC acquisitions in pediatric CT. These coefficients are substantially different between ATCM and FTC modes of operation and enable a more accurate assessment of patient-specific organ dose in the clinical setting.

60 APPLIED LIFE SCIENCES↗

Poster — Thur Eve — 20: CTDI Measurements using a Radiochromic Film-based clinical protocol

The purpose of the study was evaluating accuracy and reproducibility of a radiochromic film-based protocol to measure computer tomography dose index (CTDI) as a part of annual QA on CT scanners and kV-CBCT systems attached to linear accelerators. Energy dependence of Gafchromic XR-QA2 ® film model was tested over imaging beam qualities (50 – 140 kVp). Film pieces were irradiated in air to known values of air-kerma (up to 10 cGy). Calibration curves for each beam quality were created (Film reflectance change Vs. Air-kerma in air). Film responses for same air-kerma values were compared. Film strips were placed into holes of a CTDI phantom and irradiated for several clinical scanning protocols. Film reflectance change was converted into dose to water and used to calculate CTDIvol values. Measured and tabulated CTDIvol values were compared. Average variations of ±5.2% in the mean film reflectance change were observed in the energy range of 80 to 140 keV, and 11.1% between 50 and 140 keV. Measured CTDI values were in average 10% lower than tabulated CTDI values for CT-simulators, and 44% higher for CBCT systems. Results presented a mean variation for the same machine and protocol of 2.6%. Variation of film response is within ±5% resulting in ±15% systematic error in dose estimation if a single calibration curve is used. Relatively large discrepancy between measured and tabulated CTDI values strongly support the trend towards replacing CTDI value with equilibrium dose measurement in the center of cylindrical phantom, as suggested by TG- 111.

07 ISOTOPE AND RADIATION SOURCES↗

Low tube voltage dual source computed tomography to reduce contrast media doses in adult abdomen examinations: A phantom study

Purpose: To evaluate the potential of low tube voltage dual source (DS) single energy (SE) and dual energy (DE) computed tomography (CT) to reduce contrast media (CM) dose in adult abdominal examinations of various sizes while maintaining soft tissue and iodine contrast-to-noise ratio (CNR). Methods: Four abdominal phantoms simulating a body mass index of 16 to 35 kg/m{sup 2} with four inserted syringes of 0, 2, 4, and 8 mgI/ml CM were scanned using a 64-slice DS-CT scanner. Six imaging protocols were used; one single source (SS) reference protocol (120 kV, 180 reference mAs), four low kV SE protocols (70 and 80 kV using both SS and DS), and one DE protocol at 80/140 kV. Potential CM reduction with unchanged CNRs relative to the 120 kV protocol was calculated along with the corresponding increase in radiation dose. Results: The potential contrast media reductions were determined to be approximately 53% for DS 70 kV, 51% for SS 70 kV, 44% for DS 80 kV, 40% for SS 80 kV, and 20% for DE (all differences were significant, P < 0.05). Constant CNR could be achieved by using DS 70 kV for small to medium phantom sizes (16–26 kg/m{sup 2}) and for all sizes (16–35 kg/m{sup 2}) when using DS 80 kV and DE. Corresponding radiation doses increased by 60%–107%, 23%–83%, and 6%–12%, respectively. Conclusions: DS single energy CT can be used to reduce CM dose by 44%–53% with maintained CNR in adult abdominal examinations at the cost of an increased radiation dose. DS dual-energy CT allows reduction of CM dose by 20% at similar radiation dose as compared to a standard 120 kV single source.

60 APPLIED LIFE SCIENCES↗