Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONTAMINATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Estimating Persistent Mass Flux of Volatile Contaminants from the Vadose Zone to Ground Water

Contaminants may persist for long time periods within low permeability portions of the vadose zone where they cannot be effectively treated and are a potential continuing source of contamination to groundwater. Setting appropriate vadose zone remediation goals requires evaluating these persistent sources in terms of their impact on meeting groundwater remediation goals. One-dimensional approaches for estimating transport of volatile contaminants in the vadose zone are considered and compared to a one-dimensional flux-continuity-based assessment of vapor-phase contaminant movement from the vadose zone to the groundwater. The flux-continuity-based assessment demonstrates that the ability of the groundwater to move contaminant away from the water table controls the vapor-phase mass flux from the vadose zone across the water table. Limitations of the one-dimensional approaches are then discussed with respect to the need for further method development and application of two- or three-dimensional numerical modeling. The carbon tetrachloride (CT) plume at the U.S. Department of Energy Hanford Site is used as an example of a site where persistent vadose zone contamination needs to be considered in the context of groundwater remediation.

54 ENVIRONMENTAL SCIENCES↗

The phyto-remediation of radioactively contaminated land - a feasible approach or just bananas?

Soil is an essential component of all terrestrial ecosystems and is under increasing threat from human activity. Techniques available for removing radioactive contamination from soil and aquatic substrates are limited and often costly to implement; particularly over large areas. Frequently, bulk soil removal, with its attendant consequences, is a significant component of the majority of contamination incidents. Alternative techniques capable of removing contamination or exposure pathways without damaging or removing the soil are therefore of significant interest. An increasing number of old nuclear facilities are entering 'care and maintenance', with significant ground contamination issues. Phyto-remediation - the use of plants' natural metabolic processes to remediate contaminated sites is one possible solution. Its key mechanisms include phyto-extraction and phyto-stabilisation. These are analogues of existing remedial techniques. Further, phyto-remediation can improve soil quality and stability and restore functionality. Information on the application of phyto-remediation in the nuclear industry is widely distributed over an extended period of time and sources. It is therefore difficult to quickly and effectively identify which plants would be most suitable for phyto-remediation on a site by site basis. In response, a phyto-remediation tool has been developed to address this issue. Existing research and case studies were reviewed to understand the mechanisms of phyto-remediation, its effectiveness and the benefits and limitations of implementation. The potential for cost recovery from a phyto-remediation system is also briefly considered. An overview of this information is provided here. From this data, a set of matrices was developed to guide potential users through the plant selection process. The matrices take the user through a preliminary screening process to determine whether the contamination present at their site is amenable to phyto-remediation, and to give a rough indication as to what plants might be suitable. The second two allow the user to target specific plant species that would be most likely to successfully establish based on prevailing site conditions. The outcome of this study is a phyto-remediation tool that can facilitate the development of phyto-remediation projects, avoiding the need for in-depth research to identify optimal plant species on a case-by-case basis. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solar Development on Contaminated and Disturbed Lands

Land classified as contaminated and disturbed across the United States has the potential to host developments of utility-scale solar power. This report examines the prospect of developing utility- and commercial-scale concentrated solar power (CSP) and solar photovoltaics (PV) technologies on degraded and environmentally contaminated lands. The potential for solar development on contaminated anddisturbed lands was assessed, and for the largest and highest solar resource sites, the economic impacts and feasibility were evaluated. Developing solar power on contaminated and disturbed lands can help create jobs and revitalize local and state economies, and selecting these sites over greenfield sites can potentially have permitting and environmental mitigation advantages. The U.S.Department of Energy (DOE) SunShot goals call for 632 GW of PV and 83 GW of CSP to be deployed by 2050. Conservative land-use estimates of this study (10 acres per megawatt) show that there are disturbed and environmentally contaminated lands throughout the country that could be suitable for utility-scale solar power, and, that there is sufficient land area to meet SunShot solar deployment goals. The purpose of this assessment is to improve the understanding of these sites and facilitate solar developers' selection of contaminated and disturbed sites for development.

14 SOLAR ENERGY↗

Geochemical Characterization of Chromate Contamination in the 100 Area Vadose Zone at the Hanford Site

The major objectives of the proposed study were to: 1.) determine the leaching characteristics of hexavalent chromium [Cr(VI)] from contaminated sediments collected from 100 Area spill sites; 2.) elucidate possible Cr(VI) mineral and/or chemical associations that may be responsible for Cr(VI) retention in the Hanford Site 100 Areas through the use of i.) macroscopic leaching studies and ii.) microscale characterization of contaminated sediments; and 3.) provide information to construct a conceptual model of Cr(VI) geochemistry in the Hanford 100 Area vadose zone. In addressing these objectives, additional benefits accrued were: (1) a fuller understanding of Cr(VI) entrained in the vadose zone that will that can be utilized in modeling potential Cr(VI) source terms, and (2) accelerating the Columbia River 100 Area corridor cleanup by providing valuable information to develop remedial action based on a fundamental understanding of Cr(VI) vadose zone geochemistry. A series of macroscopic column experiments were conducted with contaminated and uncontaminated sediments to study Cr(VI) desorption patterns in aged and freshly contaminated sediments, evaluate the transport characteristics of dichromate liquid retrieved from old pipelines of the 100 Area; and estimate the effect of strongly reducing liquid on the reduction and transport of Cr(VI). Column experiments used the < 2 mm fraction of the sediment samples and simulated Hanford groundwater solution. Periodic stop-flow events were applied to evaluate the change in elemental concentration during time periods of no flow and greater fluid residence time. The results were fit using a two-site, one dimensional reactive transport model. Sediments were characterized for the spatial and mineralogical associations of the contamination using an array of microscale techniques such as XRD, SEM, EDS, XPS, XMP, and XANES. The following are important conclusions and implications. Results from column experiments indicated that most of contaminant Cr travels fast through the sediments and appears as Cr(VI) in the effluents. The significance of this for groundwater concentrations would, however, depend on the mass flux of recharge to the water table. adsorption of Cr(VI) to sediments from spiked Cr(VI) solution is low; calculated retardation coefficients are close to one. Calcium polysulfide solutions readily reduced Cr(VI) to Cr(III) in column experiments. However a significant amount of the Cr(VI) was mobilized ahead of the polysulfide solution front. This has significant implications for in-situ reductive remediation techniques. The experiments suggest that it would be difficult to design a remedial measure using infiltration of liquid phase reductants without increasing transport of Cr(VI) toward the water table. The microscopic characterization results are consistent with the column studies. Cr(VI) is found as ubiquitous coatings on sediment grain surfaces. Small, higher concentration, chromium sites are associated with secondary clay mineral inclusions, with occasional barium chromate minerals, and reduced to Cr(III) in association with iron oxides that are most likely magnetite primary minerals. Within the restricted access domains of sediment matrix, ferrous iron could also diffuse from in situ, high-surface-area minerals to cause the reductive immobilization of chromate. This process may be favored at microscale geochemical zones where ferrous iron could be supplied. Once nucleated, micrometer-scale precipitates are favored as growing locales for further accumulation, causing the formation of discrete zones of Cr(III).

54 ENVIRONMENTAL SCIENCES↗

Normalized Tritium Quantification Approach (NoTQA) a Method for Quantifying Tritium Contaminated Trash and Debris at LLNL

Several facilities and many projects at LLNL work exclusively with tritium. These operations have the potential to generate large quantities of Low-Level Radioactive Waste (LLW) with the same or similar radiological characteristics. A standardized documented approach to characterizing these waste materials for disposal as radioactive waste will enhance the ability of the Laboratory to manage them in an efficient and timely manner while ensuring compliance with all applicable regulatory requirements. This standardized characterization approach couples documented process knowledge with analytical verification and is very conservative, overestimating the radioactivity concentration of the waste. The characterization approach documented here is the Normalized Tritium Quantification Approach (NoTQA). This document will serve as a Technical Basis Document which can be referenced in radioactive waste characterization documentation packages such as the Information Gathering Document. In general, radiological characterization of waste consists of both developing an isotopic breakdown (distribution) of radionuclides contaminating the waste and using an appropriate method to quantify the radionuclides in the waste. Characterization approaches require varying degrees of rigor depending upon the radionuclides contaminating the waste and the concentration of the radionuclide contaminants as related to regulatory thresholds. Generally, as activity levels in the waste approach a regulatory or disposal facility threshold the degree of required precision and accuracy, and therefore the level of rigor, increases. In the case of tritium, thresholds of concern for control, contamination, transportation, and waste acceptance are relatively high. Due to the benign nature of tritium and the resulting higher regulatory thresholds, this less rigorous yet conservative characterization approach is appropriate. The scope of this document is to define an appropriate and acceptable characterization method for quantification of tritium contaminated trash and debris. The characterization technique is applicable to surface and subsurface tritium contaminated materials with surfaces amenable to swiping. Some limitations of this characterization technique are identified.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Final work plan : investigation of potential contamination at the former CCC/USDA grain storage facility in Hanover, Kansas.

The Commodity Credit Corporation (CCC), an agency of the U.S. Department of Agriculture (USDA), operated a grain storage facility at the northeastern edge of the city of Hanover, Kansas, from 1950 until the early 1970s. During this time, commercial grain fumigants containing carbon tetrachloride were in common use by the grain storage industry to preserve grain in their facilities. In February 1998, trace to low levels of carbon tetrachloride (below the maximum contaminant level [MCL] of 5.0 {micro}g/L) were detected in two private wells near the former grain storage facility at Hanover, as part of a statewide USDA private well sampling program that was implemented by the Kansas Department of Health and Environment (KDHE) near former CCC/USDA facilities. In April 2007, the CCC/USDA collected near-surface soil samples at 1.8-2 ft BGL (below ground level) at 61 locations across the former CCC/USDA facility. All soil samples were analyzed by the rigorous gas chromatograph-mass spectrometer analytical method (purge-and-trap method). No contamination was found in soil samples above the reporting limit of 10 {micro}g/kg. In July 2007, the CCC/USDA sampled indoor air at nine residences on or adjacent to its former facility to address the residents concerns regarding vapor intrusion. Low levels of carbon tetrachloride were detected at four of the nine homes. Because carbon tetrachloride found in private wells and indoor air at the site might be linked to historical use of fumigants containing carbon tetrachloride at its former grain storage facility, the CCC/USDA is proposing to conduct an investigation to determine the source and extent of the carbon tetrachloride contamination associated with the former facility. This investigation will be conducted in accordance with the intergovernmental agreement between the KDHE and the Farm Service Agency (FSA) of the USDA. The investigation at Hanover will be performed, on behalf of the CCC/USDA, by the Environmental Science Division of Argonne National Laboratory. Argonne is a nonprofit, multidisciplinary research center operated by UChicago Argonne, LLC, for the U.S. Department of Energy (DOE). The CCC/USDA has entered into an interagency agreement with DOE, under which Argonne provides technical assistance to the CCC/USDA with environmental site characterization and remediation at its former grain storage facilities. Seven technical objectives have been proposed for the Hanover investigation. They are as follows: (1) Identify the sources and extent of soil contamination beneath the former CCC/USDA facility; (2) Characterize groundwater contamination beneath the former CCC/USDA facility; (3) Determine groundwater flow patterns; (4) Define the vertical and lateral extent of the groundwater plume outside the former CCC/USDA facility; (5) Evaluate the aquifer and monitor the groundwater system; (6) Identify any other potential sources of contamination that are not related to activities of the CCC/USDA; and (7) Determine whether there is a vapor intrusion problem at the site attributable to the former CCC/USDA facility. The technical objectives will be accomplished in a phased approached. Data collected during each phase will be evaluated to determine whether the subsequent phase is necessary. The KDHE project manager and the CCC/USDA will be contacted during each phase and kept apprised of the results. Whether implementation of each phase of work is necessary will be discussed and mutually agreed upon by the CCC/USDA and KDHE project managers.

54 ENVIRONMENTAL SCIENCES↗

Uranium Contamination in the 300 Area: Emergent Data and their Impact on the Source Term Conceptual Model

The primary objectives of this characterization activity were to: 1) determine the extent of uranium contamination in the sediments, 2) quantify the leachable (labile) concentration of uranium in the sediments, and 3) create a data set that could be used to correlate the present data to existing 300 Area data. In order to meet these objectives, sediments collected from wells 399-2-5 (C5708), 299-3-22 (C5706) and 299-4-14 (C5707) were analyzed for moisture content, 1:1 sediment:water extracts (which provide soil pH, electrical conductivity [EC], cation, and anion data), total carbon and inorganic carbon content, 8 M nitric acid extracts (which provide a measure of the total leachable sediment content of the contaminants), microwave-assisted digestion (which results in total digestion of the sediment), and carbonate leaches (which provide an assessment of the concentration of labile uranium present in the sediments). Additionally, pore waters present in select samples were extracted using ultracentrifugation. The mobility characteristics of uranium vary within the multiple subsurface zones that contain residual contaminant uranium. Principal subsurface zones include 1) the vadose zone, 2) a zone through which the water table rises and falls, 3) the aquifer, and 4) a zone where groundwater and river water interact beneath the river shoreline. Principal controls on mobilization include the form of the residual uranium (e.g., crystalline minerals, amorphous precipitates/coatings, sorbed onto sediment), the transporting medium (e.g., water infiltration from the land surface, groundwater), and the rate of exchange between the form and transporting medium. The bicarbonate content of aqueous media strongly influences the rate of exchange, with relatively higher content enhancing mobility. Groundwater has a higher bicarbonate content than river water or other freshwater sources, such as utility and potable water systems. The variety of processes affecting the mobility of uranium in the subsurface, along with the numerous potential compartments where residual contamination may be located, presents challenges for predicting uranium movement through environmental pathways. The processes responsible for the persistence of the plume may involve cycling of uranium between the aquifer and overlying zone through which the water table fluctuates. Contaminated groundwater is moved upward into the lower vadose zone, and when the water table subsequently falls, contaminated moisture is left behind. Some of the uranium in groundwater may become sorbed to sediment in that zone, to subsequently slowly release. Also, near the Columbia River in the zone of groundwater/river water interaction, where the bicarbonate content is lowered because of infiltrating river water, the tendency for uranium to adsorb onto sediment is enhanced, thus slowing dissipation via the groundwater pathway. Fluctuations in the Columbia River stage are the driving mechanism for the rise and fall of the water table beneath the 300 Area, and also for creating the dynamic hydraulic and geochemical environment found in the zone of interaction beneath the shoreline.

300 Area↗

Technical Basis for Evaluating Surface Barriers to Protect Groundwater from Deep Vadose Zone Contamination

This document presents a strategy for evaluating the effectiveness of surface barriers for site-specific deep vadose zone remediation. The strategy provides a technically defensible approach to determine the depth to which a surface barrier can effectively isolate contaminants in the vadose at a specific site as a function of subsurface properties, contaminant distribution, barrier design, and infiltration control performance. The strategy also provides an assessment of additional data and information needs with respect to surface barrier performance for deep vadose zone applications. The strategy addresses the linkage between surface barriers and deep vadose zone in situ remediation activities, monitoring issues, and emerging science, technology, and regulatory objectives. In short, the report documents the existing knowledge base, identifies knowledge needs (based on data gaps), and suggests tasks whose outcomes will address those knowledge needs. More important, the report serves as a starting point to engage the regulator and stakeholder community on the viability of deploying surface barriers for deep vadose zone contamination. As that engagement unfolds, a systematic methodology can be formalized and instituted. The strategy is focused on deep vadose zone contamination and the methods needed to determine the impact to groundwater from those deep vadose zone contaminants. Processes that affect surface barrier performance, recharge in the areas surrounding the surface barrier, and the near-surface vadose zone beneath the barrier are acknowledged but are not addressed by this strategy. In addition, the collection of site-specific data on contaminant distribution and geologic structure and properties are programmatic responsibilities and are not provided by this strategy.

58 GEOSCIENCES↗

Optimized purification methods for metallic contaminant removal from directly recycled Li-ion battery cathodes

Metallic contaminants pose a significant challenge to the viability of directly recycling Li-ion batteries. To date, few strategies exist to selectively remove metallic impurities from mixtures of shredded end-of-life material (black mass; BM) without concurrently damaging the structure and electrochemical performance of the target active material. We herein present tailored methods to selectively ionize two major contaminants—Al and Cu—while retaining a representative cathode (LiNi 0.33 Mn 0.33 Co 0.33 O 2 ; NMC-111) intact. This BM purification process is conducted at moderate temperatures in a KOH-based solution matrix. We rationally evaluate approaches to increase both the kinetic corrosion rate and the thermodynamic solubility of Al 0 and Cu 0 , and evaluate the impact of these treatment conditions on the structure, chemistry, and electrochemical performance of NMC. Specifically, we explore the impacts of chloride-based salts, a strong chelating agent, elevated temperature, and sonication on the rate and extent of contaminant corrosion, while concurrently evaluating the effects on NMC. The reported BM purification process is then demonstrated on samples of “simulated BM” containing a practically relevant 1 wt% concentration of Al or Cu. Increasing the kinetic energy of the purifying solution matrix through elevated temperature and sonication accelerates the corrosion of metallic Al and Cu, such that ∼100% corrosion of 75 μm Al and Cu particles is achieved within 2.5 hr. Further, we determine that effective mass transport of ionized species critically impacts the efficacy of Cu corrosion, and that saturated Cl – hinders rather than accelerates Cu corrosion by increasing solution viscosity and introducing competitive pathways for Cu surface passivation. The purification conditions do not induce bulk structural damage to NMC, and electrochemical capacity is maintained in half-cell format. Testing in full cells suggests that a limited quantity of residual surface species are present after treatment, which initially disrupt electrochemical behavior at the graphite anode but are subsequently consumed. Process demonstration on simulated BM suggests that contaminated samples—which prior to treatment show catastrophic electrochemical performance—can be recovered to pristine electrochemical capacity. The reported BM purification method offers a compelling and commercially viable solution to address contamination, particularly in the “fine” fraction of BM where contaminant sizes are on the same order of magnitude as NMC and where traditional separation approaches are unfeasible. Thus, this optimized BM purification technique offers a pathway towards viable direct recycling of BM feedstocks that would otherwise be unusable.

25 ENERGY STORAGE↗

Options To Cleanup Site-wide Vadose Zone Contamination At The Hanford Site, WA, State

The U.S. Department of Energy (DOE) Hanford Site in south central Washington State lies along the Columbia River and is one of DOE's largest legacy waste management sites. Enormous radionuclide and chemical inventories exist below-ground. These include Resource Conservation and Recovery Act (RCRA) storage facilities where hazardous and radioactive contaminants were discharged and leaked to the soil surface and to the deep vadose zone and groundwater. The vadose zone is also contaminated from facilities regulated by the RCRA and Comprehensive Environmental Response Compensation and Liability Act (CERCLA) Act. Hanford now contains as much as 28,300 cubic meters of soil contaminated with radionuclides from liquid wastes released near processing facilities. The Hanford Federal Facility Agreement and Consent Order, Tri-Party Agreement (TPA) has set the completion of the cleanup of these sites by 2024. There are numerous technical and regulatory challenges to cleanup of the vadose zone at the Hanford site. This paper attempts to identify the categories of deep vadose zone problem and identifies a few possible regulatory options to clean up the site under the mix of state and federal regulatory authorities. There are four major categories of vadose contamination areas at the Hanford Site. The first is laterally extensive with intermediate depth (ground surface to about 45 meters depth) mostly related to high volume effluent discharge into cribs, ponds and ditches of designated CERCLA facilities. The second is dominated by laterally less extensive mostly related to leaks from RCRA tank farms. The later contamination is often commingled at depth with wastes from adjacent CERCLA facilities. The third category is from the high volume CERCLA facilities extending from the surface to more than 60 meters below ground. Contamination from the later category crosses the entire thickness of the vadose zone and reached groundwater. The fourth category is the lower volume waste sites. There are multiple management options to clean up the above four categories of vadose zones sites. The following are some of the options considered for detailed evaluation: - Maintain separate decision processes for each RCRA and CERCLA units/waste sites with a more accommodating schedule. - Create new vadose zone operable units with limited geographical boundaries regardless of site category/origin and make an integrated decision. - Expand the existing CERCLA groundwater operable units to include the deep vadose zone - Use a combination of the above. Each option has pros and cons and regulatory limitations. Detailed evaluation of these options is required to support a cost effective expedited cleanup. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Waste management attendant mercury issues involving mercury-contaminated debris at the Y-12 site, Oak Ridge, Tennessee - 15573

The purpose of this evaluation is to gain a better understanding of the extent of mercury contamination within the four Y-12 major mercury contaminated complexes, to identify strategies to reduce the quantity and concentration of mercury in the D and D debris prior to disposal, and to evaluate disposition options for the mercury-contaminated debris that are protective of human health and the environment. Although the focus of this evaluation is on the mercury-contaminated debris that exceeds regulatory requirements for direct land disposal, other media contaminated with mercury are noted when relevant to the discussions. The information presented in this report can be used to plan future D and D and remedial actions (RA) within Y-12 mercury-contaminated zones. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Land-use planning scenarios for contaminated land: comparing EPA, state, and tribal scenarios - 15642

Land-use planning focusing on future disposition of public lands, forests and, former agricultural or industrial land, must take into account demographic and economic factors as well as future needs and availability of recreational open space, arable land, and water for growing populations. Planning requires the balancing of competing interests for 'growth', open space, and preservation of cultural, ecological and natural resources Landscapes with soil, surface water, and groundwater contaminated by former military, industrial, mining or agricultural uses, pose special challenges, many of which have been addressed under the rubric of 'brown-fields'. Land-use decisions or recommendations can be based mainly on economic/social interests taking into account projected demographic changes, or they can be based mainly on environmental issues taking into account contamination levels, remediation costs and technologies, and health risk issues. Future land-use is interwoven with cleanup goals. Where unrestricted future land-use is anticipated or desired, cleanup levels for soil and groundwater must be low enough to allow such uses without unacceptable health risks. Where such cleanup levels are unattainable for fiscal or technological reasons, residual contamination will remain, and future uses, particularly for groundwater, must be restricted, requiring engineered barriers and institutional controls to interdict future exposure pathways from contaminated environmental media to receptors (residents, recreationists, employees). Although contamination and hazard may persist for centuries, planning beyond a generation or two incurs great uncertainties in demographics, policies, economic, and climate-related changes. The Environmental Protection Agency and various states have established categories of clean-up levels corresponding to future industrial, recreational and residential use, with variations on these themes. This paper examines the spectrum of land-uses, and emphasizes a distinctions between -residential- and -unrestricted- as applied to future land-uses, particularly involving groundwater. Land-use determinations can be proposed and evaluated by a myriad of regulatory policies, guidance documents, and processes, including comprehensive land-use planning documents, Baseline Risk Assessments, Remedial Investigation/Feasibility documents and Records of Decision - which are not the focus of this study. This study instead focuses on gradations in different residential, recreational and industrial land-use scenarios and their relation to contamination of soil and groundwater. The Consortium for Risk Evaluation with Stakeholder Participation (CRESP) instituted this study to help understand the varying land-use versus clean-up decisions at the Department of Energy's environmental management sites, particularly Hanford (Washington State). (authors)

54 ENVIRONMENTAL SCIENCES↗

Selective Determination of Methylmercury Levels in Mercury-Contaminated Topsoils from Oak Ridge, TN - 18163

Mercury (Hg) is a strong neurotoxin that affects the central and peripheral nervous system. Mercury has several organomercury species that bio-accumulate in many different environments. In early 1950's, elemental mercury was used for manufacturing of various components nuclear weapons systems in the Y-12 Security Complex in Oak Ridge, TN. The mercury released to the environment contaminated the facilities, soil, sediment, surface water, and groundwater within the boundaries of the Y-12 Plant and the downstream environment along the East Fork Poplar Creek. Remediation efforts have been made since then to alleviate the amount of mercury contamination that impacts the soil, water and wildlife at the Y-12 complex and surrounding areas. Yet, mercury levels in the water still exceed both the regulatory limits (51 ng/L) and the remediation goal (200 μg/L). Methylmercury (CH{sub 3}Hg) is the most toxic form of mercury that bio-accumulates exponentially compared to other forms of mercury. It is hypothesized that contaminated soils contain significant levels of methylmercury that contributes to contamination in nearby freshwater ecosystems in Y-12 complex. The objective of this study was to develop analytical method for selective determination of CH{sub 3}Hg from mercury-contaminated soils that contained elevated levels of inorganic mercury, Hg(II). Attempts were made to selectively extract CH{sub 3}Hg from spiked template soils via extraction in dilute hydrochloric (HCl) and nitric acids (HNO{sub 3}). The latter performed better than HCl affording quantitative extraction of CH{sub 3}Hg with minimal extraction of Hg(II). Under same circumstance, only about 5% of Hg(II) extracted from the soil matrix. Coprecipitation efforts were made using Bi(III), Fe(III) and La(III) alone and in conjunction with thiourea and L-cysteine. A combination of La(III) + L-cysteine afforded highest elimination of Hg(II) from solutions. Thiourea was not suitable for coprecipitation of Hg(II) as it also precipitated up to 67% of CH{sub 3}Hg from simulated soil solutions. Cold vapor generation (CVG) interfaced to ICP-MS was optimized for selective determination of CH{sub 3}Hg{sup +}. Calibration curves were established with CH{sub 3}Hg standards in La(III) and 0.1% L-cysteine and 5% (v/v) HNO{sub 3} by CVG-ICP-MS. The method was validated by determination of CH{sub 3}Hg in sediment reference material (SQC1238) and Estuarine sediment (ERM - CC580) containing trace levels of CH{sub 3}Hg in Hg(II) matrix. The procedure was applied to floodplain soils from Oak Ridge, TN. Methylmercury levels were in the range of 0.031 to 0.047 μg/g. The results indicated that CH{sub 3}Hg{sup +} levels were substantially lower inorganic Hg(II), still though CH{sub 3}Hg at these levels could be significant source of persistent mercury contamination in freshwater systems. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Self-Navigating Robotic Assistant for Long-term Wide Area Floor Contamination Monitoring - 18213

For Routine Contamination Testing (RCT) of an operational nuclear facility or one undergoing Decontamination and Decommissioning (D and D), workers utilize specified travel corridors (enclosed hallways or areas designated with tape or rope in open spaces) to minimize the risk of spreading contamination. Radiation health technicians must continually monitor these areas for contamination to minimize worker dose and prevent its spread to uncontrolled areas. For many sites, it is impractical for the technician to adequately survey such areas. The Nuclear Robotics Group (NRG) at UT Austin has developed a self-navigating robotic platform equipped with radiation detectors to augment the technician to improve both survey coverage and frequency. While maintaining a controlled velocity and floor-to-sensor distance, the system takes radiation measurements to identify and/or localize contamination sources. Readings above background levels are reported to a remote workstation to allow technicians to then respond accordingly. The completion of these mundane tasks by a robot allows the trained technicians to focus instead on operational tasks, D and D, or responding to alarms. The robot generates a map using a Lidar range sensor with established Simultaneous Localization and Mapping (SLAM) techniques. Range data is then compared to previously generated maps for robot localization and autonomous navigation. To maximize coverage, the robot executes a Complete Coverage Path Planning (CCPP) algorithm using a static map that is discretized into cells to assure comprehensive yet efficient coverage. As the system executes the generated plan, it builds a radiation map of the area for the technician to validate and verify the results. If contamination is detected, the robot will minimize the spread of contamination by stopping, sounding an alarm, and alerting the remote technician. The proposed system allows for long-term deployment with minimal human intervention. It is robust to both highly dynamic obstacles (i.e. personnel) and low dynamic changes (i.e. temporally stored cart) in the environment. This is accomplished through continuous spatiotemporal updating of the static map, and the utilization of a supervisory controller that allows the system to reliably respond to unexpected events or states (i.e. low battery, closed door, etc.). While the supervisory controller can respond to temporary complications, the system also recognizes the environment can change slowly over time necessitating that the CCPP automatically be updated to account for observed 'permanent' changes to the environment. To do this, the robot uses intermediate probabilistic data to make intelligent planning decisions offline while still maintaining local reactive obstacle avoidance and safety features. The self-updating of the map allows the robot to run longer without the need to remake the map, leading to more consistent monitoring data and less maintenance from the human technician. This paper will review the current system hardware, the CCPP algorithm, the supervisory controller, the probabilistic algorithm for identifying permanent changes, and recent experiments at UT Austin to experimentally validate the reported sensor coverage. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Plant Mounds as Concentration and Stabilization Agents for Actinide Soil Contaminants in Nevada

Plant mounds or blow-sand mounds are accumulations of soil particles and plant debris around the base of shrubs and are common features in deserts in the southwestern United States. An important factor in their formation is that shrubs create surface roughness that causes wind-suspended particles to be deposited and resist further suspension. Shrub mounds occur in some plant communities on the Nevada Test Site, the Nevada Test and Training Range (NTTR), and Tonopah Test Range (TTR), including areas of surface soil contamination from past nuclear testing. In the 1970s as part of early studies to understand properties of actinides in the environment, the Nevada Applied Ecology Group (NAEG) examined the accumulation of isotopes of Pu, 241Am, and U in plant mounds at safety experiment and storage-transportation test sites of nuclear devices. Although aerial concentrations of these contaminants were highest in the intershrub or desert pavement areas, the concentration in mounds were higher than in equal volumes of intershrub or desert pavement soil. The NAEG studies found the ratio of contaminant concentration of actinides in soil to be greater (1.6 to 2.0) in shrub mounds than in the surrounding areas of desert pavement. At Project 57 on the NTTR, 17 percent of the area was covered in mounds while at Clean Slate III on the TTR, 32 percent of the area was covered in mounds. If equivalent volumes of contaminated soil were compared between mounds and desert pavement areas at these sites, then the former might contain as much as 34 and 62 percent of the contaminant inventory, respectively. Not accounting for radionuclides associated with shrub mounds would cause the inventory of contaminants and potential exposure to be underestimated. In addition, preservation of shrub mounds could be important part of long-term stewardship if these sites are closed by fencing and posting with administrative controls.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Carbon contamination of extreme ultraviolet (EUV) mask and its effect on imaging

Carbon contamination of extreme ultraviolet (EUV) masks and its effect on imaging is a significant issue due to lowered throughput and potential effects on imaging performance. In this work, a series of carbon contamination experiments were performed on a patterned EUV mask. Contaminated features were then inspected with a reticle scanning electron microscope (SEM) and printed with the SEMA TECH Berkeley Microfield-Exposure tool (MET) [1]. In addition, the mask was analyzed using the SEMA TECH Berkeley Actinic-Inspection tool (AIT) [2] to determine the effect of carbon contamination on the absorbing features and printing performance. To understand the contamination topography, simulations were performed based on calculated aerial images and resist parameters. With the knowledge of the topography, simulations were then used to predict the effect of other thicknesses of the contamination layer, as well as the imaging performance on printed features.

36 MATERIALS SCIENCE↗

Water reactive polyurethane grouting for deep vadose zone contaminant immobilization

Contaminants in the deep vadose zone (DVZ) pose a long-term threat to groundwater, human health, and the environment. Polyurethane grouting is a type of chemical grouting that is potentially advantageous in immobilizing contaminants in DVZs. Polyurethane resin has low viscosity that makes it feasible to penetrate and fill the pore space between fine particles. Here, in this study a series of laboratory pressure grouting and leaching tests were conducted to simulate and assess the effectiveness of polyurethane grouting for immobilizing contaminants in DVZs. Soil with fine particles was prepared with 127 I (as iodide) that served as a non-radioactive surrogate for radioactive 129 I. After grouting and curing, leaching tests were used to measure and compare contaminant diffusivity and leachability index values. Additionally, changes in porosity and saturated hydraulic conductivity of grouted soil were measured. X-Ray Computer Tomography (XCT) results showed that the cured polyurethane was distributed nearly homogeneously and approximately half of the voids were filled with cured polyurethane. Grouting reduced the saturated hydraulic conductivity of soil by 37 %. The effective diffusivity decreased by more than 80 % as compared with the ungrouted soil. The leachability index of the grouted soil was 6.5; meeting the criteria established by the U.S. Nuclear Regulatory Commission (NRC) standard. The results obtained in this study provide a valuable assessment of polyurethane grouting for iodide immobilization in the DVZ and indicate this approach may be a viable method for contaminant remediation in DVZ soils.

Contaminant Diffusion↗

Long-lived contaminants in cyclotron-produced radiopharmaceuticals: measurement and dosimetry

Oxygenated target waters of cyclotron targets contain long-lived contaminants due to (p,n) reactions in the HAVAR target window that are spalled into the target water. These contaminants are largely removed during the synthesis of the final imaging agent. Currently the USP requires that the final drug product be 99.5% pure, so the total activity of the long-lived contaminants can be no more than 0.5% of the final radiopharmaceutical product. A method has been developed to identify and quantify the primary contaminants using high resolution gamma spectroscopy and VRF, a new spectrum analysis tool. Uptake, retention, and excretion functions for each of the contaminating isotopes in a soluble, injected chemical form have also been calculated using International Commission on Radiological Protection (ICRP) Publication 123 models and are presented in the Appendices A and B of Electronic Supplementary Material. In addition, specific organ and effective dose coefficients were also calculated using ICRP Publication 103 tissue weighting factors and are also presented in the Appendices A and B of Electronic Supplementary Material. As a result, typical imaging agents have contaminant loads far below the USP limit and contribute negligible doses to the patients receiving the drugs.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗