Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMMERCIAL SECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Connected Loads – Grid Connected Appliances: Deployment IoT Solution for Fault Detection and Diagnostics

As one of the most energy-intensive end-uses in the commercial buildings sector, supermarkets consume around 50 kWh/ft 2 ( or 537.6 kWh/m 2 ) of electricity annually, or more than 2 million kWh of electricity per year for a typical store. The biggest consumer of energy in a supermarket is its refrigeration system, which accounts for 40–60% of its total electricity usage and is equivalent to about 2–3% of the total energy consumed by commercial buildings in United States, or around 0.5 quadrillion Btu (or 0.53 quadrillion KJ). Also, the supermarket refrigeration system is one of the biggest consumers of refrigerants. Current supermarket refrigeration systems rely on high global warming potential hydrofluorocarbon refrigerants. Reducing refrigerant usage or using environment friendly alternatives can result in significant climate benefits. Transcritical CO2 refrigeration systems have attracted more attention in recent years because of their zero-carbon emission advantages compared with traditional refrigerants. These systems are widely used in commercial buildings such as supermarkets. The refrigeration system can also be adapted to handle flexible building loads and be integrated into grid response transactive control to balance the supply and demand of the electric grid. Even minor improvements in the efficiency and operational reliability of supermarket refrigeration systems can create significant value in terms of saving energy, improving food quality, protecting the environment, reducing carbon footprint, and enhancing electric grid resilience. For decarbonization, the new administration has set a target to reduce greenhouse gas emissions by 50– 52% by 2030 and targeting a carbon-neutral economy by 2050. For electrification, the goal is to achieve 100% clean electricity by 2035. Such decarbonization and electrification in the building sector require that energy consumption in buildings be reduced significantly. Therefore, the building sector must continuously adopt new technologies to achieve its energy and carbon emission goals. One of the most fundamental technologies is the Internet of Things (IoT). IoT has proven to be an effective solution for the building domain, including building information/energy modeling, smart buildings, etc. Although much progress has been made in the development of IoT-based building energy systems, there is still a lack of reliable, scalable, and affordable IoT-based automated fault and degradation diagnostics (AFDDs) solutions. Such solutions would enable deployment of advanced algorithms into real systems to archive the projected energy benefits. This study reviews existing IoT solutions developed for building energy– related application and developed a simple but effective AFDD IoT deployment solution, including developing a suitable IoT architecture and conducting easy and scalable deployment by leveraging a common cloud-based IoT service.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

In-space Servicing, Assembly, and Manufacturing (ISAM) State of Play 2022 Edition

The future of spaceflight will yield increasingly more ambitious missions to support civil, national security, and commercial space sectors. Achieving these ambitious missions is not feasible using the traditional paradigm of launching an integrated, fully functioning system on a single launch vehicle. For example, science and human exploration missions will desire payloads that are larger than any foreseeable launch vehicle fairing, national security missions will require persistent assets that are mobile and resilient, and commercial space missions will require cost-effective ways to update to the latest technology on orbit. In-space Servicing, Assembly, and Manufacturing (ISAM) can vastly expand the performance, availability, and lifetime of space systems compared to the traditional paradigm of launching an asset with no intent to ever touch it again. ISAM capabilities foster an ecosystem that changes the space operations paradigm, creating the foundation for sustainable exploration and serving as a multiplier for other capabilities like space logistics, power generation, and reusability. Previous achievements in ISAM have enabled ambitious human and robotic space missions. NASA’s International Space Station (ISS) operations and maintenance, servicing missions of the Hubble Space Telescope (HST), and Northrop Grumman’s Mission Extension Vehicle (MEV) demonstrate the dramatic operational missions that can be achieved using ISAM capabilities. Many current and upcoming flight demonstrations are advancing areas that will enable the next generation of civil, national security, and commercial space missions. This document describes the current state of ISAM missions, capabilities, and developments. Compiling and organizing the available ISAM capabilities will help mission designers incorporate ISAM technologies into their concepts, create the starting point for technology development plans and roadmaps, and provide technologists a survey of the field they are developing. This document divides the ISAM capabilities into 11 capability areas that describe the functions or activities that would be performed in space using ISAM. This version of the ISAM State of Play is part of a continuing journey to encourage the use of ISAM capabilities in space. Compiling and organizing the current state of ISAM provides a simple resource for those working in the ISAM ecosystem to ensure that the advancements being made build upon the investments of the past. The state of play is ever changing as new capabilities are developed, and this document will be periodically updated to ensure that it is relevant to those who need it in the future.

ISAM↗

SUbsonic Single Aft eNgine (SUSAN) Power/Propulsion System Hardware-in-the-Loop Test Results

Electrified Aircraft Propulsion (EAP) technology offers a promising path forward for reducing greenhouse gas emissions and other negative environmental effects from the commercial aviation sector. EAP systems can reduce fuel burn and improve performance over state-of the-art designs, however the increased complexity and highly coupled nature of these systems present challenges that require new control approaches. The SUbsonic Single Aft eNgine (SUSAN) Electrofan is a concept aircraft developed by NASA as a reference design for a commercial transport aircraft with a highly integrated hybrid-electric powertrain. This paper summarizes the results of a Hardware-in-the-Loop (HIL) test of a control architecture developed for the SUSAN power/propulsion system (PPS). The test was performed in the Hybrid Propulsion Emulation Rig (HyPER) facility at the NASA Glenn Research Center (GRC) and involved a real-time reference model of the SUSAN PPS and control system running with a sub-scale electro-mechanical system replacing one of the PPS subsystems. A side-by-side comparison of the simulated and real systems in the HIL test results shows that the control architecture functions well in both the simulation and the real-time HIL environment. In both cases the controller is able to simultaneously deliver the required thrust response and balance power levels between the electrical and turbomachinery subsystems.

Jonah J Sachs-Wetstone↗

SUbsonic Single Aft eNgine (SUSAN) Power/Propulsion System Hardware-in-the-Loop Test Results

Electrified Aircraft Propulsion (EAP) technology offers a promising path forward for reducing greenhouse gas emissions and other negative environmental effects from the commercial aviation sector. EAP systems can reduce fuel burn and improve performance over state-of the-art designs, however the increased complexity and highly coupled nature of these systems present challenges that require new control approaches. The SUbsonic Single Aft eNgine (SUSAN) Electrofan is a concept aircraft developed by NASA as a reference design for a commercial transport aircraft with a highly integrated hybrid-electric powertrain. This paper summarizes the results of a Hardware-in-the-Loop (HIL) test of a control architecture developed for the SUSAN power/propulsion system (PPS). The test was performed in the Hybrid Propulsion Emulation Rig (HyPER) facility at the NASA Glenn Research Center (GRC) and involved a real-time reference model of the SUSAN PPS and control system running with a sub-scale electro-mechanical system replacing one of the PPS subsystems. A side-by-side comparison of the simulated and real systems in the HIL test results shows that the control architecture functions well in both the simulation and the real-time HIL environment. In both cases the controller is able to simultaneously deliver the required thrust response and balance power levels between the electrical and turbomachinery subsystems.

EAP↗

Use of a State-Level Integrated Assessment Model for Policy Analysis: An Uncertainty Analysis of Energy and Water

This presentation discusses some recent uncertainty assessment work being done on climate policy issues at the state level. The work is being done with the Platform for Regional Integrated Modeling and Analysis (PRIMA), a new climate change policy assessment framework developed at Pacific Northwest National Laboratory in Richland and Seattle, Washington and College Park, Maryland. The central computaional engine of PRIMA is the Global Change Assessment Model (GCAM), a dynamic-recursive integrated assessment model of the world economy, climate policy, and climate change that that has been regionalized to provide policy analysis down to the level of U.S. states. The PRIMA framework also includes detailed sectoral models that address issues in the energy-land-water interface geospatially at the sub-national level as the climate change and socioeconomic change occur. This presentation illustrates two uncertainty analyses conducted with GCAM and with water demand and supply components of PRIMA. The energy uncertainty analysis was conducted with GCAM alone and examines the impact of aggressive residential and commercial building equipment standards across the United States in the context of socioeconomic and climate uncertainty. The analysis focuses on the impact on future net energy service costs under aggressive standards in the residential and commercial building sectors from 2005 to 2050. The analysis uses a combination of discrete scenarios and Monte Carlo sampling approaches to address uncertainties. Results for Arizona and Florida are used to illustrate whether aggressive building equipment standards save energy and reduce net energy service costs when compared with current standards. Analysis of the output indicates a robust result under a broad range of future socioeconomic, policy, and climate scenarios. The water uncertainty analysis demonstrates a multi-model approach used to bound the prospects for future water shortages in Florida, given socioeconomic uncertainty and future water supply under a future climate. In this analysis, water demands from GCAM are coupled with a water management model that simulates regulated streamflows and water supply deficits given naturalized streamflows, water demands, and reservoir operating rules. The naturalized streamflows are simulated with a regional earth system model coupled to a river routing model. The climate is obtained from a regional climate projection of the Intergovernmental Panel on Climate Change (IPCC) Representative Concentration Pathway 8.5 (RCP 8.5) for all of the river basins in the United States. GCAM is used in Monte Carlo mode to estimate the outer bounds of water demand given socioeconomic uncertainty and RCP 8.5 climate. Future water demand is downscaled to a river basin level for Florida in high, low, and middle cases and is compared with available water supply for the same region for RCP 8.5 climate to identify the potential location and severity of water shortages.

Climate change, policy, mitigation, impacts, uncer↗

Connected Loads – Grid Connected Appliances: Commercial Refrigeration System Fault Detection and Diagnostics

As one of the most energy-intensive end-uses in the commercial buildings sector, supermarkets consume around 50 kWh/ft 2 (or 537.6 kWh/m 2 ) of electricity annually, or more than 2 million kWh of electricity per year for a typical store. The biggest consumer of energy in a supermarket is its refrigeration system, which accounts for 40–60% of its total electricity usage and is equivalent to about 2–3% of the total energy consumed by commercial buildings in United States, or around 0.5 quadrillion Btu (or 0.53 quadrillion KJ). Also, the supermarket refrigeration system is one of the biggest consumers of refrigerants. Current supermarket refrigeration systems rely on high global warming potential hydrofluorocarbon refrigerants. Reducing refrigerant usage or using environment friendly alternatives can result in significant climate benefits. Transcritical CO2 refrigeration systems have attracted more attention in recent years because of their zero-carbon emission advantages compared with traditional refrigerants. These systems are widely used in commercial buildings such as supermarkets. The refrigeration system can also be adapted to handle flexible building loads and be integrated into grid response transactive control to balance the supply and demand of the electric grid. Even minor improvements in the efficiency and operational reliability of supermarket refrigeration systems can create significant value in terms of saving energy, improving food quality, protecting the environment, reducing carbon footprint, and enhancing electric grid resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Job/Task Analysis: Enhancing the Commercial Building Workforce Through the Development of Foundational Materials; Preprint

For many commercial building operation job categories, industry consensus has not been reached on the knowledge, skills, and abilities that practitioners should possess. The goal of this guidance is to help streamline the minimum competencies taught or tested by organizations catering to building operations and maintenance personnel while providing a basis for developing and comparing new andexisting training programs in the commercial building sector. The developed JTAs will help individuals identify opportunities to enhance their professional skills, enable industry to identify an appropriately skilled workforce, and allow training providers to ensure that they are providing the highest quality product possible.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy and resource consumption

The present and projected energy requirements for the United States are discussed. The energy consumption and demand sectors are divided into the categories: residential and commercial, transportation, and industrial and electrical generation (utilities). All sectors except electrical generation use varying amounts of fossile fuel resources for non-energy purposes. The highest percentage of non-energy use by sector is industrial with 71.3 percent. The household and commercial sector uses 28.4 percent, and transportation about 0.3 percent. Graphs are developed to project fossil fuel demands for non-energy purposes and the perdentage of the total fossil fuel used for non-energy needs.

Source record↗

Does Commercial Space Really Need MOA?

The Mission Operations Assurance (MOA) discipline actively participates as a project member to achieve their common objective of full mission success while also providing an independent risk assessment to the Project Manager. The cornerstone element of MOA is the independent assessment of the risks the project faces in executing its mission. Especially as the project approaches critical mission events, it becomes imperative to clearly identify and assess the risks the project faces. This has been the paradigm for robotic space exploration missions, but does the same apply to commercial space operations? This is the question which is the driver for this year's MOA track at the 18th Annual Improving Space Operations workshop in April at the Jet Propulsion Laboratory, and the question we examine in this paper. Corollaries to this driving question are why shouldn't MOA apply and are there factors beyond mission success with acceptable risk which apply to commercial space operations that are not present in government scientific missions? To address these questions, areas we focus on include risk (both mission and profit) management for commercial space operations and the practical extension of robotic mission MOA to commercial space operations. Another key area to look at is command file errors which are a major concern for deep space robotic missions, but can we worry about them less with manned missions or unmanned supply mission? Further, with the growing concern about space debris, we delve into the role of MOA relative to End-of-Mission activities. This paper examines these topics and in particular the perspectives presented at the workshop to begin charting the appropriate course for MOA in the emerging sector of Commercial Space Operations.

commercial space↗

Enabling America on the Space Frontier: The Evolution of NASA’s Commercial Space Development Toolkit

Throughout NASA’s history, the Agency has supported the development and growth of the U.S. commercial space sector via various mechanisms that have nurtured the technology, companies, people, and ideas driving an industry that today is a significant contributor to the American and global economies. This report identifies 17 such mechanisms and qualitatively examines how they have been applied across four distinct periods in NASA’s history: 1915–1960, which covers NASA’s predecessor, the National Advisory Committee on Aeronautics (NACA), and NASA’s pre-Apollo years; 1961–1980, the Apollo era; 1981–2010, the Space Shuttle era; and 2011–present, the post-Shuttle commercial era. These eras are defined by dominant technologies, programs, or economic trends. Not all 17 mechanisms were applied during each era; some are relatively recent conceptions, while others have been used throughout the history of NASA and NACA. Additionally, there is inevitably some overlap between the mechanisms; this overlap adds an element of subjectivity to the categorizations in this report. In most eras, and for most mechanisms, there are far more examples than can reasonably be summarized in a single document. Therefore, this report should not be considered an exhaustive review of every iteration of any given mechanism’s implementation. Finally, with many of these mechanisms, such as contracts, commercial space capabilities sometimes resulted as a serendipitous by-product rather than a planned outcome.

economic policy↗

Demonstration of the carbon capture with building make-up air unit

Building-integrated carbon capture technology has the potential to reduce the cost of CO 2 capture while improving indoor air quality (IAQ). To promote the adoption of CO 2 capture in a building environment, this study investigated the possibility of integrating carbon capture technology with an existing rooftop make-up air unit (MAU) system to trap CO 2 . Here, in this study, a modular compact CO 2 capture system containing amine-functionalized polymer fibers was examined. The system, which was installed at the exhaust of the MAU, captures CO 2 before it leaves the building to enter the atmosphere as a greenhouse gas. The demonstrated average amount of CO 2 captured was 1.1–1.4 mmol/g of adsorbent material. Techno-economic analysis (TEA) was further performed on the CO 2 capture system, considering material costs, energy costs, as well as transportation and regeneration costs. These results were then used to estimate the levelized cost per ton CO 2 captured (LCOC). To achieve LCOC below $\$$100/t-CO 2 , adsorbents should have working capacities of 4.9 t and 3 t-CO 2 /year for 5 years and 10 years of operation, respectively. In summary, this study highlights a viable path toward the decarbonization of the commercial buildings sector and provides quantitative performance and economic insight on the suitability of building-integrated carbon capture technology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Efficient Low-Lift cooling with Radiant Distribution, Thermal Storage and Variable-Speed Chiller Controls

The U.S. Department of Energy’s Building Technologies Program goal is to develop cost-effective technologies and building practices that will enable the design and construction of net-zero energy buildings by 2025. To support this goal, Pacific Northwest National Laboratory evaluated an integrated technology that through utilization of synergies between emerging heating, ventilation and air conditioning systems can significantly reduce energy consumption in buildings. This set consists of thermal storage, dedicated outdoor air system, radiant heating/cooling with a variable speed low-lift-optimized vapor compression system. The results show that the low-lift cooling system provides significant energy savings in many building types and climates locations. This market represents well over half of the entire U.S. commercial building sector. This analysis shows that significant cooling system efficiency gains can be achieved by integrating low-lift cooling technologies. The cooling energy savings for a standard-performance building range from 37% to 84% and, for a high-performance building, from -9% to 70%.

25 ENERGY STORAGE↗

Upgrading Limiting Peak-Power Analysis Techniques with Modern Validation and Uncertainty Quantification for the Advanced Test Reactor

Here, this work demonstrates the acceptability of the 2D deterministic transport code, HELIOS, to replace the legacy diffusion code, PDQ, for computing the peak-power performance parameters of the Advanced Test Reactor (ATR). The 95% Confidence Rule, commonly used in the commercial reactor sector, is explored to develop the so-called “reliability factors” which provide statistical confidence that the peak-power limits within the hottest location along a fuel plate, referred to as the hot-stripe, will not be exceeded. Additionally, an alternative “legacy” methodology was explored that attempts to mimic the exact PDQ analysis process used for defining the peak-power limits. The legacy methodology, involves interpolating power between regions at azimuthal boundaries subtending the regions of interest. In order to apply the 95% Confidence Rule, a statistically significant calculation-to-measurement bias must first be established. Unlike the commercial world where thousands of power observations can be collected every cycle using on-line flux mapping instrumentation, the ATR power distribution must be measured during “depressurized” zero-power measurements using fission wires in polyethylene wands. In 2012, fission wire activation data was collected during a flux run in the Advanced Test Reactor – Critical facility. Also to improve statistical validity, archival data from ATR zero power flux runs from 1977, 1986, and 1994 were digitized from scanned reports and used to create new benchmark models. Borrowing from least-squares adjustment methods commonly used for neutron activation spectroscopy, adjusted fission wire powers were calculated for all four datasets. The mean and standard deviation of the bias between a priori calculated and adjusted wire-powers was then taken as the bias and uncertainty used in the 95% Confidence Rule.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The Role of Energy Storage in Commercial Building

Motivation and Background of Study This project was motivated by the need to understand the full value of energy storage (thermal and electric energy storage) in commercial buildings, the opportunity of benefits for building operations and the potential interactions between a building and a smart grid infrastructure. On-site or local energy storage systems are not new to the commercial building sector; they have been in place in US buildings for decades. Most building-scale storage technologies are based on thermal or electrochemical storage mechanisms. Energy storage technologies are not designed to conserve energy, and losses associated with energy conversion are inevitable. Instead, storage provides flexibility to manage load in a building or to balance load and generation in the power grid. From the building owner's perspective, storage enables load shifting to optimize energy costs while maintaining comfort. From a grid operations perspective, building storage at scale could provide additional flexibility to grid operators in managing the generation variability from intermittent renewable energy resources (wind and solar). To characterize the set of benefits, technical opportunities and challenges, and potential economic values of storage in a commercial building from both the building operation's and the grid operation's view-points is the key point of this project. The research effort was initiated in early 2010 involving Argonne National Laboratory (ANL), the National Renewable Energy Laboratory (NREL), and Pacific Northwest National Laboratory (PNNL) to quantify these opportunities from a commercial buildings perspective. This report summarizes the early discussions, literature reviews, stakeholder engagements, and initial results of analyses related to the overall role of energy storage in commercial buildings. Beyond the summary of roughly eight months of effort by the laboratories, the report attempts to substantiate the importance of active DOE/BTP R&D activities in this space.

14 SOLAR ENERGY↗

Software-Defined Solutions for Managing Energy Use in Small to Medium Sized Commercial Buildings

The Project uses state-of-the-art computer science to extend the benefits of Building Automation Systems (BAS) typically found in large buildings (>100,000 square foot) to medium-sized commercial buildings (<50,000 sq ft). The BAS developed in this project, termed OpenBAS, uses an open-source and open software architecture platform, user interface, and plug-and-play control devices to facilitate adoption of energy efficiency strategies in the commercial building sector throughout the United States. At the heart of this “turn key” BAS is the platform with three types of controllers—thermostat, lighting controller, and general controller—that are easily “discovered” by the platform in a plug-and-play fashion. The user interface showcases the platform and provides the control system set-up, system status display and means of automatically mapping the control points in the system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Uncrewed Aerial Systems for Emergency Medical First Response: A Market Research Report

This report presents the findings from market research conducted for NASA’s Aerial Aid Convergent Aeronautics Solutions (CAS) exploration project, which aims to assess the current state of the market and technological readiness for Uncrewed Aerial Systems (UAS) for medical emergency first response. The research reveals a robust and rapidly growing market for UAS, with a notable emerging sector for Drones as First Responders (DFR). Despite this growth, DFR applications are currently limited by regulatory, technical, and other challenges, which restrict their use primarily to manned remote video surveillance, and therefore are primarily employed by police units. To our knowledge, there is no evidence of UAS being utilized by medical first responders for scene assessment. Limited evidence exists for closely related applications; however, these are mostly confined to pilot programs for the delivery of medical supplies or equipment. Although there has been discussion around fully autonomous DFR applications for medical purposes such as UAS ambulances or patient transport drones, these applications are generally not yet operational in practice. The technology for full autonomy, especially in guidance and control, has seen significant advancements, and recent Federal Aviation Administration (FAA)regulations are likely to accelerate adoption. Computer vision algorithms for fully autonomous medical emergency response scene surveillance are primed for advancement and deployment. A notable gap likely exists between advancements in computer vision research and what is being integrated in the commercial DFR sector. This gap is primarily due to challenges such as quality assurance for autonomous systems, the availability of application-specific training datasets for computer vision algorithms, regulatory constraints, and public perception and privacy concerns.

Joshua M Fody↗

Commercial Building Energy Asset Rating Program -- Market Research

Under contract to Pacific Northwest National Laboratory, HaydenTanner, LLC conducted an in-depth analysis of the potential market value of a commercial building energy asset rating program for the U.S. Department of Energy (DOE) Office of Energy Efficiency and Renewable Energy. The market research objectives were to: (1) Evaluate market interest and need for a program and tool to offer asset rating and rapidly identify potential energy efficiency measures for the commercial building sector. (2) Identify key input variables and asset rating outputs that would facilitate increased investment in energy efficiency. (3) Assess best practices and lessons learned from existing national and international energy rating programs. (4) Identify core messaging to motivate owners, investors, financiers, and others in the real estate sector to adopt a voluntary asset rating program and, as a consequence, deploy high-performance strategies and technologies across new and existing buildings. (5) Identify leverage factors and incentives that facilitate increased investment in these buildings. To meet these objectives, work consisted of a review of the relevant literature, examination of existing and emergent asset and operational rating systems, interviews with industry stakeholders, and an evaluation of the value implication of an asset label on asset valuation. This report documents the analysis methodology and findings, conclusion, and recommendations. Its intent is to support and inform the DOE Office of Energy Efficiency and Renewable Energy on the market need and potential value impacts of an asset labeling and diagnostic tool to encourage high-performance new buildings and building efficiency retrofit projects.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗