Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CLOCK”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

p-Wave Cold Collisions in an Optical Lattice Clock

We study ultracold collisions in fermionic ytterbium by precisely measuring the energy shifts they impart on the atoms' internal clock states. Exploiting Fermi statistics, we uncover p-wave collisions, in both weakly and strongly interacting regimes. With the higher density afforded by two-dimensional lattice confinement, we demonstrate that strong interactions can lead to a novel suppression of this collision shift. In addition to reducing the systematic errors of lattice clocks, this work has application to quantum information and quantum simulation with alkaline-earth atoms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Large Momentum Transfer Clock Atom Interferometry on the 689 nm Intercombination Line of Strontium

We report the first realization of large momentum transfer (LMT) clock atom interferometry. Using single-photon interactions on the strontium $^1S_{0^–}^3P_1$ transition, we demonstrate Mach-Zehnder interferometers with state-of-the-art momentum separation of up to 141 $\textit{ℏk}$ and gradiometers of up to 81 $\textit{ℏk}$. Furthermore, we circumvent excited state decay limitations and extend the gradiometer duration to 50 times the excited state lifetime. Because of the broad velocity acceptance of the interferometry pulses, all experiments are performed with laser-cooled atoms at a temperature of 3 μK. This work has applications in high-precision inertial sensing and paves the way for LMT-enhanced clock atom interferometry on even narrower transitions, a key ingredient in proposals for gravitational wave detection and dark matter searches.

74 ATOMIC AND MOLECULAR PHYSICS↗

Hamiltonian engineering of spin-orbit–coupled fermions in a Wannier-Stark optical lattice clock

Engineering a Hamiltonian system with tunable interactions provides opportunities to optimize performance for quantum sensing and explore emerging phenomena of many-body systems. An optical lattice clock based on partially delocalized Wannier-Stark states in a gravity-tilted shallow lattice supports superior quantum coherence and adjustable interactions via spin-orbit coupling, thus presenting a powerful spin model realization. The relative strength of the on-site and off-site interactions can be tuned to achieve a zero density shift at a “magic” lattice depth. This mechanism, together with a large number of atoms, enables the demonstration of the most stable atomic clock while minimizing a key systematic uncertainty related to atomic density. Interactions can also be maximized by driving off-site Wannier-Stark transitions, realizing a ferromagnetic to paramagnetic dynamical phase transition.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Observation of millihertz-level cooperative Lamb shifts in an optical atomic clock

Collective couplings of atomic dipoles to a shared electromagnetic environment produce a wide range of many-body phenomena. We report on the direct observation of resonant electric dipole-dipole interactions in a cubic array of atoms in the many-excitation limit. The interactions produce spatially dependent cooperative Lamb shifts when spectroscopically interrogating the millihertz-wide optical clock transition in strontium-87. We show that the ensemble-averaged shifts can be suppressed below the level of evaluated systematic uncertainties for optical atomic clocks. Additionally, we demonstrate that excitation of the atomic dipoles near a Bragg angle can enhance these effects by nearly an order of magnitude compared with nonresonant geometries. Our work demonstrates a platform for precise studies of the quantum many-body physics of spins with long-range interactions mediated by propagating photons.

Science & Technology - Other Topics↗

Quantum nonlocal modulation cancelation with distributed clocks

We demonstrate nonlocal modulation of entangled photons with truly distributed radio frequency (RF) clocks. Leveraging a custom radio-over-fiber (RFoF) system characterized via classical spectral interference, we validate its effectiveness for quantum networking by multiplexing the RFoF clock with one photon from a frequency-bin-entangled pair and distributing the coexisting quantum-classical signals over fiber. Phase modulation of the two photons reveals nonlocal correlations in excellent agreement with theory: in-phase modulation produces additional sidebands in the joint spectral intensity, while out-of-phase modulation is nonlocally canceled. Our simple, feedback-free design attains subpicosecond synchronization—namely, drift less than ~0.5 ps in a 5.5 km fiber over 30 min (fractionally only ~2×10 -8 of the total fiber delay)—and should facilitate frequency-encoded quantum networking protocols such as high-dimensional quantum key distribution and entanglement swapping, unlocking frequency-bin qubits for practical quantum communications in deployed metropolitan-scale networks.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Shift Register Clock Rate Effects on Coincidence Collection 50MHz versus 4MHz Comparison Tests

The following report identifies and quantifies the timing differences between the older slower Shift Register Coincidence/Multiplicity modules and today’s modern higher speed devices. Modern high speed Shift Register Coincidence/Multiplicity instruments employ high speed internal clocks that run at frequencies more than ten times the older units, typically 50MHz. These higher speed clocks allow for a finer time resolution when recording input pulses.

Nuclear Disarmament, Safeguards, & Physical Protec↗

Proton Improvement Plan II (PIP-II) Clock and Timing

The PIP-II timing system is planned to be a two-part system consisting of a global timing system (referred to as ACLK) that provides high level, event-based timing for the whole Fermilab accelerator complex while the second part is a RF synchronized clock system unique to the PIP-II Linac itself (referred to as LCLK). The ACLK System will make use of an external 10 MHz GPS based signal source as a reference for its 650 MHz phase lock as it is the reference frequency for the TCLK output of the system (needed to support legacy hardware around complex). The LCLK System will use a PIP-II Linac RF reference (162.5 MHz) from the Linac LLRF system to allow beam synchronized event placement. Both the ACLK and LCLK systems will have a clock output with a data frame of 16 event bits + 32 data bits with frames broadcast at 650 MHz, phase locked to the 10MHz reference in the case of ACLK and the PIP-II LLRF sourced 162.5 MHz reference in the case of LCLK.

43 PARTICLE ACCELERATORS↗

Characterization of Soft Error Rate Against Memory Elements Spacing and Clock Skew in a Logic with Triple Modular Redundancy in a 65nm Process

Single Event Effects introduce soft errors in ASICs. Design methodologies like Triple ModularRedundancy (TMR) with clock skew insertion, a system level redundancy technique is a commonpractice by designers to mitigate soft errors. However, the optimal spacing between memoryelements in a TMR in 65nm process hasn't been addressed so far. RD53SEU is a mini ASICdevelopment under the framework of the CERN RD53 collaboration to characterize the soft errorrates against the separation spacing and clock skew between memory elements in a TMR. Thisarticle describes the architecture and design aspects of the various test structures on the RD53SEUtest chip.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Artificial Intelligence-Assisted Method for Dementia Detection Using Images from the Clock Drawing Test

Background: Widespread dementia detection could increase clinical trial candidates and enable appropriate interventions. Since the Clock Drawing Test (CDT) can be potentially used for diagnosing dementia-related disorders, it can be leveraged to develop a computer-aided screening tool. Objective: To evaluate if a machine learning model that uses images from the CDT can predict mild cognitive impairment or dementia. Methods: Images of an analog clock drawn by 3,263 cognitively intact and 160 impaired subjects were collected during in-person dementia evaluations by the Framingham Heart Study. We processed the CDT images, participant’s age, and education level using a deep learning algorithm to predict dementia status. Results: When only the CDT images were used, the deep learning model predicted dementia status with an area under the receiver operating characteristic curve (AUC) of 81.3% ± 4.3%. A composite logistic regression model using age, level of education, and the predictions from the CDT-only model, yielded an average AUC and average F1 score of 91.9% ±1.1% and 94.6% ±0.4%, respectively. Conclusion: Our modeling framework establishes a proof-of-principle that deep learning can be applied on images derived from the CDT to predict dementia status. When fully validated, this approach can offer a cost-effective and easily deployable mechanism for detecting cognitive impairment.

Neurosciences & Neurology↗

Clocking connector replaces adapter cables

Single cable using simplified, versatile clocking connector satisfies clocking variations that previously required many cables. Connector consists of specially fabricated grommet follower dial housing, dial assembly, and modified insert.

Arriola, S.↗

Measurement of the gravitational redshift using a clock in an orbiting satellite

A hydrogen maser clock is proposed for enclosure in an orbiting satellite to measure the gravitational effect on time scales with high accuracy. This experiment is used to test the principle of equivalence for clocks in space. Extremely narrow linewidth of Fe-57 radiation and absorption due to Mossbauer effect over 75 ft vertical distance was used to confirm the prediction of the equivalence principle to 1 part in 100. The fractional frequency shift of a satellite-borne oscillator observed from earth is also given.

Vessot, R. F. C.↗

A fault-tolerant clock

Computers must operate correctly even though one or more of components have failed. Electronic clock has been designed to be insensitive to occurrence of faults; it is substantial advance over any known clock.

Daley, W. P.↗

Recent field test results using OMEGA transmissions for clock synchronization

The results are presented of clock synchronization experiments using OMEGA transmissions from North Dakota on 13.10 kHz and 12.85 kHz. The OMEGA transmissions were monitored during April 1974 from NASA tracking sites located at Madrid, Spain; Canary Island; and Winkfield, England. The sites are located at distances between 6600 kilometers (22,100 microseconds) to 7300 kilometers (24,400 microseconds) from North Dakota. The data shows that cycle identification of the received signals was accomplished. There are, however, discrepancies between the measured and calculated propagation delay values which have not been explained, but seem to increase with distance between the receiver and the transmitter. The data also indicates that three strategically located OMEGA transmitting stations may be adequate to provide worldwide coverage for clock synchronization to within plus or minus two (2) microseconds.

Chi, A. R.↗

A relativistic analysis of clock synchronization

The relativistic conversion between coordinate time and atomic time is reformulated to allow simpler time calculations relating analysis in solar-system barycentric coordinates (using coordinate time) with earth-fixed observations (measuring earth-bound proper time or atomic time.) After an interpretation of terms, this simplified formulation, which has a rate accuracy of about 10 to the minus 15th power, is used to explain the conventions required in the synchronization of a world wide clock network and to analyze two synchronization techniques-portable clocks and radio interferometry. Finally, pertinent experiment tests of relativity are briefly discussed in terms of the reformulated time conversion.

Thomas, J. B.↗

VLBI clock synchronization

The potential accuracy of VLBI (very long baseline interferometry) for clock epoch and rate comparisons was demonstrated by results from long- and short-baseline experiments. It was found that atomic clocks at widely separated sites (several thousand kilometers apart) can be synchronized to within several nanoseconds from a few minutes of VLBI observations and to within one nanosecond from several hours of observations.

Counselman, C. C., III↗