Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CAT SCANNING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

SU-E-T-378: Limits and Possibilities of a Simplistic Approach to Whole Breast Radiation Therapy Planning

Purpose: Challenges for radiation therapy in developing countries include unreliable infrastructure and high patient load. We propose a system to treat whole breast in the prone position without computed tomography and/or planning software. Methods: Six parameters are measured using calipers and levels with the patient prone in the treatment position. (1) The largest separation; (2) the angle that separation makes with the horizontal; (3) the separation 2 cm posterior to the nipple; (4) the vertical distance between these two separations; (5) the sup/inf length and (6) angle of the desired posterior field edge. The data in (5) (6) and (2) provide field length, collimator and gantry angles. Isocenter is set to the midpoint of (1), anterior jaw setting is 20cm (half-beam setup), and the dose is prescribed to a point 1.5 cm anterior to isocenter. MUs and wedge angles are calculated using an MU calculator and by requiring 100% dose at that point and 100-105% at the midpoint of (3). Measurements on 30 CT scans were taken to obtain the data 1-6. To test the resulting MU/wedge combinations, they were entered into Eclipse (Varian) and dose distributions were calculated. The MU/wedge combinations were recorded and tabulated. Results: Performing a dose volume histogram analysis, the contoured breast V95 was 90.5%, and the average V90 was 94.1%. The maximum dose never exceeded 114.5%, (average 108%). The lung V20 was <5% for 96.7%, and the heart V5 was <10% for 93.3% of our sample. Conclusion: A method to provide prone whole breast treatment without CT-planning was developed. The method provides reasonable coverage and normal tissue sparing. This approach is not recommended if imaging and planning capabilities are available; it was designed to specifically avoid the need for CT planning and should be reserved to clinics that need to avoid that step.

60 APPLIED LIFE SCIENCES↗

Coregistration of Prechemotherapy PET-CT for Planning Pediatric Hodgkin's Disease Radiotherapy Significantly Diminishes Interobserver Variability of Clinical Target Volume Definition

Purpose: To assess the interobserver variability in clinical target volume (CTV) definitions when using registered {sup 18}F-labeled deoxyglucose positron emission tomography (FDG-PET-CT) versus side-by-side image sets in pediatric Hodgkin's disease (HD). Methods and Materials: Prechemotherapy FDG-PET-CT scans performed in the treatment position were acquired from 20 children (median age, 14 years old) with HD (stages 2A to 4B) and registered with postchemotherapy planning CT scans. The patients had a median age of 14 years and stages of disease ranging between 2A and 4B. Image sets were coregistered using a semiautomatic coregistration system. The biological target volume was defined on all the coregistered images as a guide to defining the initial site of involvement and to avoid false-positive or negative results. Five radiation oncologists independently defined the CTV for all 20 patients: once using separate FDG-PET-CT images as a guide (not registered) to define CTVa and once using the registered FDG-PET-CT data to define CTVb. The total volumes were compared, as well as their coefficients of variation (COV). To assess the interobserver variability, the percentages of intersection between contours drawn by all observers for each patient were calculated for CTVa and for CTVb. Results: The registration of a prechemotherapy FDG-PET-CT scan caused a change in the CTV for all patients. Comparing CTVa with CTVb showed that the mean CTVb increased in 14 patients (range, 0.61%-101.96%) and decreased in 6 patients (range, 2.97%-37.26%). The COV for CTVb significantly decreased for each patient; the mean COVs for CTVa and CTVb were 45% (21%-65%) and 32% (13%-57%), respectively (p = 0.0004). The percentage of intersection among all CTVbs for the five observers increased significantly by 89.77% (1.99%-256.41%) compared to that of CTVa (p = 0.0001). Conclusions: High observer variability can occur during CT-based definition of CTVs for children diagnosed with HD. Registration of FDG-PET and planning CT images resulted in significantly greater consistency of tumor volume definition.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A patient alignment solution for lung SBRT setups based on a deformable registration technique

Purpose: In this work, the authors propose a novel registration strategy for translation-only correction scenarios of lung stereotactic body radiation therapy setups, which can achieve optimal dose coverage for tumors as well as preserve the consistency of registrations with minimal human interference. Methods: The proposed solution (centroid-to-centroidor CTC solution) uses the average four-dimensional CT (A4DCT) as the reference CT. The cone-beam CT (CBCT) is deformed to acquire a new centroid for the internal target volume (ITV) on the CBCT. The registration is then accomplished by simply aligning the centroids of the ITVs between the A4DCT and the CBCT. Sixty-seven cases using 64 patients (each case is associated with separate isocenters) have been investigated with the CTC method and compared with the conventional gray-value (G) mode and bone (B) mode registration methods. Dosimetric effects among the tree methods were demonstrated by 18 selected cases. The uncertainty of the CTC method has also been studied. Results: The registration results demonstrate the superiority of the CTC method over the other two methods. The differences in the D99 and D95 ITV dose coverage between the CTC method and the original plan is small (within 5%) for all of the selected cases except for one for which the tumor presented significant growth during the period between the CT scan and the treatment. Meanwhile, the dose coverage differences between the original plan and the registration results using either the B or G method are significant, as tumor positions varied dramatically, relative to the rib cage, from their positions on the original CT. The largest differences between the D99 and D95 dose coverage of the ITV using the B or G method versus the original plan are as high as 50%. The D20 differences between any of the methods versus the original plan are all less than 2%. Conclusions: The CTC method can generate optimal dose coverage to tumors with much better consistency compared with either the G or B method, and it is especially useful when the tumor position varies greatly from its position on the original CT, relative to the rib cage.

60 APPLIED LIFE SCIENCES↗

Thromboembolic Complications after Zenith{sup ®} Low Profile Endovascular Graft for Infrarenal Abdominal Aneurysms

PurposeThe purpose of this study was to objectify and evaluate risk factors for thromboembolic complications after treatment with a Zenith{sup ®} Low Profile Endovascular Graft (Zenith LP). Results were compared with those in the recent literature on endovascular aortic repair (EVAR) and with the thromboembolic complications in the patient group treated with a Zenith Flex Endovascular Graft in our institute in the period before the use of the Zenith LP.Materials and MethodsAll consecutive patients who were suitable for treatment with a Zenith LP endograft between October 2010 and December 2011 were included. The preprocedural computed tomography scan (CT), procedural angiographic images, and the postprocedural CT scans were evaluated for risk factors for and signs of thromboembolic complications. All patients treated between December 2007 and November 2012 with a Zenith Flex endograft were retrospectively evaluated for thromboembolic complications.ResultsIn the study period 17 patients were treated with a LP Zenith endograft. Limb occlusion occurred in 35 % of the patients. Limb occlusions occurred in 24 % of the limbs at risk (one limb occluded twice). In one patient two risk factors for limb occlusion were identified. Between December 2007 and November 2012, a total of 43 patients were treated with a Zenith Flex endograft. No limb occlusion or distal embolization occurred.ConclusionDespite that this was a small retrospective study, the Zenith LP endograft seems to be associated with more frequent thromboembolic complications compared with the known limb occlusion rates in the literature and those of the patients treated with a Zenith Flex endograft in our institute.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-580: New Tumor Modeling Using 3D Gel Dosimeter for Brain Stereoctactic Radiotherpy (SRT)

Purpose: The purpose of this study is to develop new tumor model using 3D printing with 3D dosimeter for brain stereoctactic radiotherpy (SRT). Methods: BANG{sup 3} polymer gel was prepared and the gel-filled glass vials were irradiated with a 6 MV photon beam to acquire the calibration curve that present the change of R2 (1/T{sub 2}) value with dose. Graded doses from 0 to 12 Gy with an interval of 2 Gy were delivered. A kit for calibration of gel dosimeter and an 2 tumor model phantoms with a spherical shape were produced using a 3D printer with a polylactic acid after its 3D images were created using Autodesk software. 3D printed tumor phantoms and EBT3 films were irradiated to compare with treatment plan. After irradiation, vials for calibration and tumor model phantoms were scanned at 9.4T MRI. The spin-spin relaxation times (T{sub 2}) according to the each dose were calculated to evaluate the dose response. Acquired images were analyzed using an ImageJ. Scanned MRI images of tumor models were transferred treatment planning system and these were registered to the CT images. In all treatment plans, two arc plans (CW and CCW) were designed to deliver 50 Gy for 10 fractions. For first PTV, treatment plan was accurately designed that 95% of dose to cover 100% of PTV. But 2nd PTV was not intentionally cover 100% of PTV to evaluate the intensity of delivered tumor phantom with polymer gel. We compared the 3D dose distributions obtained from measurements with the 3D printed phantom and calculated with the TPS. Results: 3D printed phantom with a polymer gel was successfully produced. The dose distributions showed qualitatively good agreement among gel, film, and RTP data. Conclusion: A hybrid phantom represents a useful to validate the 3D dose distributions for patient-specific QA.

60 APPLIED LIFE SCIENCES↗

Dose Calculation on KV Cone Beam CT Images: An Investigation of the Hu-Density Conversion Stability and Dose Accuracy Using the Site-Specific Calibration

Precise calibration of Hounsfield units (HU) to electron density (HU-density) is essential to dose calculation. On-board kV cone beam computed tomography (CBCT) imaging is used predominantly for patients' positioning, but will potentially be used for dose calculation. The impacts of varying 3 imaging parameters (mAs, source-imager distance [SID], and cone angle) and phantom size on the HU number accuracy and HU-density calibrations for CBCT imaging were studied. We proposed a site-specific calibration method to achieve higher accuracy in CBCT image-based dose calculation. Three configurations of the Computerized Imaging Reference Systems (CIRS) water equivalent electron density phantom were used to simulate sites including head, lungs, and lower body (abdomen/pelvis). The planning computed tomography (CT) scan was used as the baseline for comparisons. CBCT scans of these phantom configurations were performed using Varian Trilogy{sup TM} system in a precalibrated mode with fixed tube voltage (125 kVp), but varied mAs, SID, and cone angle. An HU-density curve was generated and evaluated for each set of scan parameters. Three HU-density tables generated using different phantom configurations with the same imaging parameter settings were selected for dose calculation on CBCT images for an accuracy comparison. Changing mAs or SID had small impact on HU numbers. For adipose tissue, the HU discrepancy from the baseline was 20 HU in a small phantom, but 5 times lager in a large phantom. Yet, reducing the cone angle significantly decreases the HU discrepancy. The HU-density table was also affected accordingly. By performing dose comparison between CT and CBCT image-based plans, results showed that using the site-specific HU-density tables to calibrate CBCT images of different sites improves the dose accuracy to {approx}2%. Our phantom study showed that CBCT imaging can be a feasible option for dose computation in adaptive radiotherapy approach if the site-specific calibration is applied.

61 RADIATION PROTECTION AND DOSIMETRY↗

WE-A-17A-09: Exploiting Electromagnetic Technologies for Real-Time Seed Drop Position Validation in Permanent Implant Brachytherapy

Purpose: To report on preliminary results validating the performance of a specially designed LDR brachytherapy needle prototype possessing both electromagnetic (EM) tracking and seed drop detection abilities. Methods: An EM hollow needle prototype has been designed and constructed in collaboration with research partner Philips Healthcare. The needle possesses conventional 3D tracking capabilities, along with a novel seed drop detection mechanism exploiting local changes of electromagnetic properties generated by the passage of seeds in the needle's embedded sensor coils. These two capabilities are exploited by proprietary engineering and signal processing techniques to generate seed drop position estimates in real-time treatment delivery. The electromagnetic tracking system (EMTS) used for the experiment is the NDI Aurora Planar Field Generator. The experiment consisted of dropping a total of 35 seeds in a prismatic agarose phantom, and comparing the 3D seed drop positions of the EMTS to those obtained by an image analysis of subsequent micro-CT scans. Drop position error computations and statistical analysis were performed after a 3D registration of the two seed distributions. Results: Of the 35 seeds dropped in the phantom, 32 were properly detected by the needle prototype. Absolute drop position errors among the detected seeds ranged from 0.5 to 4.8 mm with mean and standard deviation values of 1.6 and 0.9 mm, respectively. Error measurements also include undesirable and uncontrollable effects such as seed motion upon deposition. The true accuracy performance of the needle prototype is therefore underestimated. Conclusion: This preliminary study demonstrates the potential benefits of EM technologies in detecting the passage of seeds in a hollow needle as a means of generating drop position estimates in real-time treatment delivery. Such tools could therefore represent a potentially interesting addition to existing brachytherapy protocols for rapid dosimetry validation. Equipments and fundings for this project were provided by Philips Medical.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-G-BRD-08: End-To-End Targeting Accuracy of the Gamma Knife for Trigeminal Neuralgia

Purpose: Current QA procedures verify accuracy of individual equipment parameters, but may not include CT and MRI localizers. This study uses an end-to-end approach to measure the overall targeting errors in individual patients previously treated for trigeminal neuralgia. Methods: The trigeminal nerve is simulated by a 3 mm long, 3.175 mm (1/8 inch) diameter MRI contrast-filled cavity embedded within a PMMA plastic capsule. The capsule is positioned within the head frame such that the cavity position matches the Gamma Knife coordinates of 10 previously treated patients. Gafchromic EBT2 film is placed at the center of the cavity in coronal and sagittal orientations. The films are marked with a pin prick to identify the cavity center. Treatments are planned for delivery with 4 mm collimators using MRI and CT scans acquired with the clinical localizer boxes and acquisition protocols. Coordinates of shots are chosen so that the cavity is centered within the 50% isodose volume. Following irradiation, the films are scanned and analyzed. Targeting errors are defined as the distance between the pin prick and the centroid of the 50% isodose line. Results: Averaged over 10 patient simulations, targeting errors along the x, y and z coordinates (patient left-to-right, posterior-anterior, head-to-foot) were, respectively, −0.060 +/− 0.363, −0.350 +/− 0.253, and 0.364 +/− 0.191 mm when MRI was used for treatment planning. Planning according to CT exhibited generally smaller errors, namely 0.109 +/− 0.167, −0.191 +/− 0.144, and 0.211 +/− 0.94 mm. The largest errors in MRI and CT planned treatments were, respectively, y = −0.761 and x = 0.428 mm. Conclusion: Unless patient motion or stronger MRI image distortion in actual treatments caused additional errors, all patients received the prescribed dose, i.e., the targeted section of the trig±eminal nerve was contained within the 50% isodose surface in all cases.

60 APPLIED LIFE SCIENCES↗

Computer-aided pulmonary image analysis in small animal models

Purpose: To develop an automated pulmonary image analysis framework for infectious lung diseases in small animal models. Methods: The authors describe a novel pathological lung and airway segmentation method for small animals. The proposed framework includes identification of abnormal imaging patterns pertaining to infectious lung diseases. First, the authors’ system estimates an expected lung volume by utilizing a regression function between total lung capacity and approximated rib cage volume. A significant difference between the expected lung volume and the initial lung segmentation indicates the presence of severe pathology, and invokes a machine learning based abnormal imaging pattern detection system next. The final stage of the proposed framework is the automatic extraction of airway tree for which new affinity relationships within the fuzzy connectedness image segmentation framework are proposed by combining Hessian and gray-scale morphological reconstruction filters. Results: 133 CT scans were collected from four different studies encompassing a wide spectrum of pulmonary abnormalities pertaining to two commonly used small animal models (ferret and rabbit). Sensitivity and specificity were greater than 90% for pathological lung segmentation (average dice similarity coefficient > 0.9). While qualitative visual assessments of airway tree extraction were performed by the participating expert radiologists, for quantitative evaluation the authors validated the proposed airway extraction method by using publicly available EXACT’09 data set. Conclusions: The authors developed a comprehensive computer-aided pulmonary image analysis framework for preclinical research applications. The proposed framework consists of automatic pathological lung segmentation and accurate airway tree extraction. The framework has high sensitivity and specificity; therefore, it can contribute advances in preclinical research in pulmonary diseases.

60 APPLIED LIFE SCIENCES↗

Is Image Registration of Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography for Head-and-Neck Cancer Treatment Planning Necessary?

Purpose: To evaluate dosimetry and patterns of failure related to fluorodeoxyglucose-positron emission tomography (FDG-PET)-defined biological tumor volumes (BTVs) for head-and-neck squamous cell carcinoma (HNSCC) treated with definitive radiotherapy (RT). Methods and Materials: We conducted a retrospective study of 91 HNSCC patients who received pretreatment PET/CT scans that were not formally used for target delineation. The median follow-up was 34.5 months. Image registration was performed for PET, planning CT, and post-RT failure CT scans. Previously defined primary (CT{sub PRIMARY}) and nodal (CT{sub NODE}) gross tumor volumes (GTV) were used. The primary BTV (BTV{sub PRIMARY}) and nodal BTV (BTV{sub NODE}) were defined visually (PET{sub vis}). The BTV{sub PRIMARY} was also contoured using 40% and 50% peak PET activity (PET{sub 40,} PET{sub 50}). The recurrent GTVs were contoured on post-RT CT scans. Dosimetry was evaluated on the planning-CT and pretreatment PET scan. PET and CT dosimetric/volumetric data was compared for those with and without local-regional failure (LRF). Results: In all, 29 of 91 (32%) patients experienced LRF: 10 local alone, 7 regional alone, and 12 local and regional. BTVs and CT volumes had less than complete overlap. BTVs were smaller than CT-defined targets. Dosimetric coverage was similar between failed and controlled groups as well as between BTVs and CT-defined volumes. Conclusions: PET and CT-defined tumor volumes received similar RT doses despite having less than complete overlap and the inaccuracies of image registration. LRF correlated with both CT and PET-defined volumes. The dosimetry for PET- and/or CT-based tumor volumes was not significantly inferior in patients with LRF. CT-based delineation alone may be sufficient for treatment planning in patients with HNSCC. Image registration of FDG-PET may not be necessary.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Changes in Cervical Cancer FDG Uptake During Chemoradiation and Association With Response

Purpose: Previous research showed that pretreatment uptake of F-18 fluorodeoxyglucose (FDG), as assessed by the maximal standardized uptake value (SUV{sub max}) and the variability of uptake (FDG{sub hetero}), predicted for posttreatment response in cervical cancer. In this pilot study, we evaluated the changes in SUV{sub max} and FDG{sub hetero} during concurrent chemoradiation for cervical cancer and their association with post-treatment response. Methods and Materials: Twenty-five patients with stage Ib1-IVa cervical cancer were enrolled. SUV{sub max}, FDG{sub hetero}, and metabolic tumor volume (MTV) were recorded from FDG-positron emission tomography (PET)/computed tomography (CT) scans performed pretreatment and during weeks 2 and 4 of treatment and were evaluated for changes and association with response assessed on 3-month post-treatment FDG-PET/CT. Results: For all patients, the average pretreatment SUV{sub max} was 17.8, MTV was 55.4 cm{sup 3}, and FDG{sub hetero} was -1.33. A similar decline in SUV{sub max} was seen at week 2 compared with baseline and week 4 compared with week 2 (34%). The areas of highest FDG uptake in the tumor remained relatively consistent on serial scans. Mean FDG{sub hetero} decreased during treatment. For all patients, MTV decreased more from week 2 to week 4 than from pretreatment to week 2. By week 4, the average SUV{sub max} had decreased by 57% and the MTV had decreased by 30%. Five patients showed persistent or new disease on 3-month post-treatment PET. These poor responders showed a higher average SUV{sub max}, larger MTV, and greater heterogeneity at all 3 times. Week 4 SUV{sub max} (P=.037), week 4 FDG{sub hetero} (P=.005), pretreatment MTV (P=.008), and pretreatment FDG{sub hetero} (P=.008) were all significantly associated with post-treatment PET response. Conclusions: SUV{sub max} shows a consistent rate of decline during treatment and declines at a faster rate than MTV regresses. Based on this pilot study, pretreatment and week 4 of treatment represent the best time points for prediction of response.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-E-17A-06: Organ Dose in Abdomen-Pelvis CT: Does TG 111 Equilibrium Dose Concept Better Accounts for KVp Dependence Than Conventional CTDI?

Purpose: In CT imaging, a desirable quality assurance (QA) dose quantity should account for the dose variability across scan parameters and scanner models. Recently, AAPM TG 111 proposed to use equilibrium dose-pitch product, in place of CT dose index (CTDI100), for scan modes involving table translation. The purpose of this work is to investigate whether this new concept better accounts for the kVp dependence of organ dose than the conventional CTDI concept. Methods: The adult reference female extended cardiac-torso (XCAT) phantom was used for this study. A Monte Carlo program developed and validated for a 128-slice CT system (Definition Flash, Siemens Healthcare) was used to simulate organ dose for abdomenpelvis scans at five tube voltages (70, 80, 100, 120, 140 kVp) with a pitch of 0.8 and a detector configuration of 2x64x0.6 mm. The same Monte Carlo program was used to simulate CTDI100 and equilibrium dose-pitch product. For both metrics, the central and peripheral values were used together with helical pitch to calculate a volume-weighted average, i.e., CTDIvol and (Deq)vol, respectively. Results: While other scan parameters were kept constant, organ dose depended strongly on kVp; the coefficient of variation (COV) across the five kVp values ranged between 70–75% for liver, spleen, stomach, pancreas, kidneys, colon, small intestine, bladder, and ovaries, all of which were inside the primary radiation beam. One-way analysis of variance (ANOVA) for the effect of kVp was highly significant (p=3e−30). When organ dose was normalized by CTDIvol, the COV across the five kVp values reduced to 7–16%. The effect of kVp was still highly significant (p=4e−4). When organ dose was normalized by (Deq)vol, the COV further reduced to 4−12%. The effect of kVp was borderline significant (p=0.04). Conclusion: In abdomen-pelvis CT, TG 111 equilibrium dose concept better accounts for kVp dependence than the conventional CTDI. This work is supported by a faculty startup fund from the Cleveland State University.

60 APPLIED LIFE SCIENCES↗

Poster — Thur Eve — 31: Dosimetric Effect of Respiratory Motion on RapidArc Lung SBRT Treatment Delivered by TrueBeam Linear Accelerator

Volumetric modulated arc therapy (VMAT) allows fast delivery of stereotactic radiotherapy. However, the discrepancies between the calculated and delivered dose distributions due to respiratory motion and dynamic multileaf collimators (MLCs) interplay are not avoidable. The purpose of this study is to investigate RapidArc lung SBRT treatment delivered by the flattening filter-free (FFF) beam and flattened beam with Varian TrueBeam machine. CIRS Dynamic Thorax Phantom with in-house made lung tumor insertion was CT scanned both in free breathing and 4DCT. 4DCT was used to determine the internal target volume. The free breathing CT scan was used for treatment planning. A 5 mm margin was given to ITV to generate a planning target volume. Varian Eclipse treatment planning was used to generate RapidArc plans based on the 6 MV flattened beam and 6MV FFF beam. The prescription dose was 48 Gy in 4 fractions. At least 95% of PTV was covered by the prescribed dose. The RapidArc plans with 6 MV flattened beam and 6MV FFF beam were delivered with Varian TrueBeam machine. The dosimetric measurements were performed with Gafchromic XR-RV3 film, which was placed in the lung tumor insertion. The interplay between the dynamic MLC-based delivery of VMAT and the respiratory motion of the tumor degraded target coverage and created undesired hot or cold dose spots inside the lung tumor. Lung SBRT RapidArc treatments delivered by the FFF beam of TrueBeam linear accelerator is superior to the flattened beam. Further investigation will be performed by Monte Carlo simulation.

60 APPLIED LIFE SCIENCES↗

Decrease of the lumpectomy cavity volume after whole-breast irradiation affects small field boost planning

To determine whether small field boost (SFB) replanning is necessary when the lumpectomy cavity (LPC) decreases during whole-breast irradiation (WBI) and what parameters might predict a change in the SFB plan. Forty patients had computed tomography (CT) simulation (CT1) within 60 days of surgery and were resimulated (CT2) after 37.8-41.4 Gy for SFB planning. A 3-field photon plan and a single en face electron plan were created on both CTs and compared. In the 26 patients who had a {>=}5 cm{sup 3} and a {>=}25% decrease in lumpectomy cavity volume (LCV) between CT scans, the SFB plan using photons was different in terms of normal breast tissue volume irradiated (BTV) (p < 0.001), and field dimensions (p < 0.001). In 20/35 patients, the energy or field size changed for electron plans on CT2, but no tested characteristics predicted for a change. Less BTV was irradiated using electrons than photons in 29% (CT1) to 37% (CT2). SFB replanning needs to be individualized to each patient because of the variety of factors that can impact dosimetric planning. Replanning is recommended when using 3-field photons if the patient has experienced a {>=}5 cm{sup 3} and a {>=}25% decrease in LCV during WBI. Some patients may benefit from electron SFB replanning but no tested characteristics reliably predict those who may benefit the most. The amount of BTV irradiated is less with electrons than in photon plans and this has the potential to improve cosmesis, a clinically important outcome in breast-conserving therapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Objective index of image fidelity for JPEG2000 compressed body CT images

Compression ratio (CR) has been the de facto standard index of compression level for medical images. The aim of the study is to evaluate the CR, peak signal-to-noise ratio (PSNR), and a perceptual quality metric (high-dynamic range visual difference predictor HDR-VDP) as objective indices of image fidelity for Joint Photographic Experts Group (JPEG) 2000 compressed body computed tomography (CT) images, from the viewpoint of visually lossless compression approach. A total of 250 body CT images obtained with five different scan protocols (5-mm-thick abdomen, 0.67-mm-thick abdomen, 5-mm-thick lung, 0.67-mm-thick lung, and 5-mm-thick low-dose lung) were compressed to one of five CRs (reversible, 6:1, 8:1, 10:1, and 15:1). The PSNR and HDR-VDP values were calculated for the 250 pairs of the original and compressed images. By alternately displaying an original and its compressed image on the same monitor, five radiologists independently determined if the pair was distinguishable or indistinguishable. The kappa statistic for the interobserver agreement among the five radiologists' responses was 0.70. According to the radiologists' responses, the number of distinguishable image pairs tended to significantly differ among the five scan protocols at 6:1-10:1 compressions (Fisher-Freeman-Halton exact tests). Spearman's correlation coefficients between each of the CR, PSNR, and HDR-VDP and the number of radiologists who responded as distinguishable were 0.72, -0.77, and 0.85, respectively. Using the radiologists' pooled responses as the reference standards, the areas under the receiver-operating-characteristic curves for the CR, PSNR, and HDR-VDP were 0.87, 0.93, and 0.97, respectively, showing significant differences between the CR and PSNR (p=0.04), or HDR-VDP (p<0.001), and between the PSNR and HDR-VDP (p<0.001). In conclusion, the CR is less suitable than the PSNR or HDR-VDP as an objective index of image fidelity for JPEG2000 compressed body CT images. The HDR-VDP is more promising than the PSNR as such an index.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Irreversible Electroporation Lung Ablation: Preliminary Results in a Porcine Model

Objective: Irreversible electroporation (IRE) uses direct electrical pulses to create permanent 'pores' in cell membranes to cause cell death. In contrast to conventional modalities, IRE has a nonthermal mechanism of action. Our objective was to study the histopathological and imaging features of IRE in normal swine lung. Materials and Methods: Eleven female swine were studied for hyperacute (8 h), acute (24 h), subacute (96 h), and chronic (3 week) effects of IRE ablation in lung. Paired unipolar IRE applicators were placed under computed tomography (CT) guidance. Some applicators were deliberately positioned near bronchovascular structures. IRE pulse delivery was synchronized with the cardiac rhythm only when ablation was performed within 2 cm of the heart. Contrast-enhanced CT scan was performed immediately before and after IRE and at 1 and 3 weeks after IRE ablation. Representative tissue was stained with hematoxylin and eosin for histopathology. Results: Twenty-five ablations were created: ten hyperacute, four acute, and three subacute ablations showed alveolar edema and necrosis with necrosis of bronchial, bronchiolar, and vascular epithelium. Bronchovascular architecture was maintained. Chronic ablations showed bronchiolitis obliterans and alveolar interstitial fibrosis. Immediate post-procedure CT images showed linear or patchy density along the applicator tract. At 1 week, there was consolidation that resolved partially or completely by 3 weeks. Pneumothorax requiring chest tube developed in two animals; no significant cardiac arrhythmias were noted. Conclusion: Our preliminary porcine study demonstrates the nonthermal and extracellular matrix sparing mechanism of action of IRE. IRE is a potential alternative to thermal ablative modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Elastoplasty: First Experience in 12 Patients

Percutaneous vertebroplasty with polymethylmethacrylate (PMMA) is used increasingly for pain relief in symptomatic neoplastic or osteoporotic compression fractures. However, restoration of the stiffness of the treated vertebrae might propagate secondary fracture of adjacent vertebrae. Elastoplasty might prevent these secondary fractures. We assessed retrospectively our experience with elastoplasty in 12 patients, focusing on silicone migration. During the period from July 2011 to January 2012, all patients with an indication for vertebroplasty were treated with elastoplasty. The exclusion criterion was the presence of posterior wall defects. Chest computed tomography (CT) scans were performed to evaluate the presence of perivertebral leakage and pulmonary embolism. The prevalence of leakage was compared with the results obtained for vertebroplasty with PMMA reported in the literature. Other complications during the postprocedural period were recorded. Twenty-one vertebral bodies in 12 patients were treated with elastoplasty. Silicone pulmonary emboli were detected on the postprocedural chest CT in 60 % (6/10) of the patients. Leakage to the perivertebral venous plexus was seen in 67 % (14/21) of the treated vertebrae. One major complication occurred: severe, medication-resistant dyspnea developed in one patient with multiple peripheral silicone emboli. This preliminary evidence suggests that VK100 silicone cement should not be used in elastoplasty because of the increased risk of silicone pulmonary embolism, when compared with the use of PMMA, which occurs worldwide. The major technical disadvantage is that the time taken for the VK100 silicone material to achieve its final strength is too long for practical application.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

[{sup 18}F]Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography (PET/CT) Physiologic Imaging of Choroidal Melanoma: Before and After Ophthalmic Plaque Radiation Therapy

Purpose: To evaluate changes in [{sup 18}F]fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) standardized uptake values (SUV) in uveal melanoma before and after plaque brachytherapy. Methods and Materials: A cohort of 217 patients diagnosed with uveal melanoma and eligible for ophthalmic plaque brachytherapy underwent preoperative PET/CT to evaluate their intraocular tumor and screen for metastasis. Subsequent to undergoing plaque brachytherapy, patients' PET/CT SUV were periodically reevaluated over 42 months. Results: In this series, 37 (17%) choroidal melanoma patients were found to have an SUV of >2.0. Of these, 18 patients were able to undergo interval follow-up PET/CT scanning. There were 3 patients with T2, 11 patients with T3, and 4 patients with T4 melanomas according to 7th edition AJCC-UICC criteria. Mean apical thickness was 8.8 mm (range, 3-12.3 mm), and the largest mean tumor diameter was 15.1 mm (range, 12-19.9 mm). The mean initial SUV was 3.7 (range, 2.1-7.3). Patients were followed for a median 16 months (range, 6-42 months). The median time to a tumor SUV of 0 was 8.0 months (range, 6-18 months). There was one case of one interval increase in SUV that diminished after circumferential laser treatment. Conclusions: Intraocular PET/CT imaging provides a physiological assessment of tumor metabolism that can be used to evaluate changes after treatment. In this study, ophthalmic plaque radiation therapy was associated with extinguished tumor PET/CT SUV over time. PET/CT imaging can be used to assess choroidal melanomas for their response to treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗