Quantitative Approach to Failure Mode and Effect Analysis for Linear Accelerator Quality Assurance

Purpose: To determine clinic-specific linear accelerator quality assurance (QA) TG-142 test frequencies, to maximize physicist time efficiency and patient treatment quality. Methods and Materials: A novel quantitative approach to failure mode and effect analysis is proposed. Nine linear accelerator-years of QA records provided data on failure occurrence rates. The severity of test failure was modeled by introducing corresponding errors into head and neck intensity modulated radiation therapy treatment plans. The relative risk of daily linear accelerator QA was calculated as a function of frequency of test performance. Results: Although the failure severity was greatest for daily imaging QA (imaging vs treatment isocenter and imaging positioning/repositioning), the failure occurrence rate was greatest for output and laser testing. The composite ranking results suggest that performing output and lasers tests daily, imaging versus treatment isocenter and imaging positioning/repositioning tests weekly, and optical distance indicator and jaws versus light field tests biweekly would be acceptable for non-stereotactic radiosurgery/stereotactic body radiation therapy linear accelerators. Conclusions: Failure mode and effect analysis is a useful tool to determine the relative importance of QA tests from TG-142. Because there are practical time limitations on how many QA tests can be performed, this analysis highlights which tests are the most important and suggests the frequency of testing based on each test's risk priority number.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Making and breaking terahertz waves with fluid plasmas

Vigorous research efforts during the past several decades have successfully closed the “terahertz gap” between microwaves and infrared light, offering new and increasingly efficient ways to produce, detect, and manipulate radiation fields in the terahertz (THz) frequency range. In our laboratory, THz time-domain spectroscopy (THz-TDS) and optical-pump THz-probe (OPTP) experiments have been routinely utilized as ultrafast spectroscopy tools to investigate a variety of emerging quantum materials and metamaterials. The ultrafast THz pulses are produced by femtosecond laser excitation of photoconductive antennas, semiconductor surfaces (InAs), and nonlinear crystals (ZnTe, GaSe, and LiNbO 3 ). Photoconductive antennas and nonlinear crystals also allow for the coherent detection of these pulses in the time domain, with amplitude and phase spectra obtained in the frequency domain via fast Fourier transform. Although such solid-state schemes are highly desirable in many aspects and thus also commonly utilized in many research laboratories and industrial applications, they typically suffer from limited bandwidths due to the absorption and frequency dispersion induced primarily by phonon resonances, limiting THz applications such as spectroscopy of emerging materials, imaging and detection, and biomedical characterization.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Imaging the event-prone coronary artery plaque

Acute coronary events, the dreaded manifestation of coronary atherosclerosis, remain one of the main contributors to mortality and disability in the developed world. The majority of those events are associated with atherosclerotic plaques-related thrombus formation following an acute disruption, that being rupture or erosion, of an event-prone lesion. These historically termed vulnerable plaques have been the target of numerous benchtop and clinical research endeavors, yet to date without solid results that would allow for early identification and potential treatment. Technological leaps in cardiovascular imaging have provided novel insights into the formation and role of the event-prone plaques. From intracoronary optical coherence tomography that has enhanced our understanding of the pathophysiological mechanisms of plaque disruption, over coronary computed tomography angiography that enables non-invasive serial plaque imaging, and positron emission tomography poised to be rapidly implemented into clinical practice to the budding field of plaque imaging with cardiac magnetic resonance, we summarize the invasive and non-invasive imaging modalities currently available in our armamentarium. Finally, the current status and potential future imaging directions are critically appraised.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-462: Lessons Learned From a Machine Incident Reporting System

Purpose: Linear accelerators must operate with minimal downtime. Machine incident logs are a crucial tool to meet this requirement. They providing a history of service and demonstrate whether a fix is working. This study investigates the information content of a large department linear accelerator incident log. Methods: Our department uses an electronic reporting system to provide immediate information to both key department staff and the field service department. This study examines reports for five linac logs during 2015. The report attributes for analysis include frequency, level of documentation, who solved the problem, and type of fix used. Results: Of the reports, 36% were documented as resolved. In another 25% the resolution allowed treatment to proceed although the reported problem recurred within days. In 5% only intermediate troubleshooting was documented. The remainder lacked documentation. In 60% of the reports, radiation therapists resolved the problem, often by clearing the appropriate faults or reinitializing a software or hardware service. 22% were resolved by physics and 10% by field service engineers. The remaining 8% were resolved by IT, Facilities, or resolved spontaneously. Typical fixes, in order of scope, included clearing the fault and moving on, closing and re-opening the patient session or software, cycling power to a sub-unit, recalibrating a device (e.g., optical surface imaging), and calling in Field Service (usually resolving the problem through maintenance or component replacement). Conclusion: The reports with undocumented resolution represent a missed opportunity for learning. Frequency of who resolves a problem scales with the proximity of the person’s role (therapist, physicist, or service engineer), which is inversely related to the permanence of the resolution. Review of lessons learned from machine incident logs can form the basis for guidance to radiation therapists and medical physicists to minimize equipment downtime and ensure safe operation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Deep learning-based temporal deconvolution for photon time-of-flight distribution retrieval

The acquisition of the time of flight (ToF) of photons has found numerous applications in the biomedical field. Over the last decades, a few strategies have been proposed to deconvolve the temporal instrument response function (IRF) that distorts the experimental time-resolved data. However, these methods require burdensome computational strategies and regularization terms to mitigate noise contributions. Herein, we propose a deep learning model specifically to perform the deconvolution task in fluorescence lifetime imaging (FLI). The model is trained and validated with representative simulated FLI data with the goal of retrieving the true photon ToF distribution. Its performance and robustness are validated with well-controlled in vitro experiments using three time-resolved imaging modalities with markedly different temporal IRFs. The model aptitude is further established with in vivo preclinical investigation. Overall, these in vitro and in vivo validations demonstrate the flexibility and accuracy of deep learning model-based deconvolution in time-resolved FLI and diffuse optical imaging.

Pandey, Vikas (ORCID:0000000154771095)↗

In-plane ultrasonic needle tracking using a fiber-optic hydrophone

Purpose: Accurate and efficient guidance of needles to procedural targets is critically important during percutaneous interventional procedures. Ultrasound imaging is widely used for real-time image guidance in a variety of clinical contexts, but with this modality, uncertainties about the location of the needle tip within the image plane lead to significant complications. Whilst several methods have been proposed to improve the visibility of the needle, achieving accuracy and compatibility with current clinical practice is an ongoing challenge. In this paper, the authors present a method for directly visualizing the needle tip using an integrated fiber-optic ultrasound receiver in conjunction with the imaging probe used to acquire B-mode ultrasound images. Methods: Needle visualization and ultrasound imaging were performed with a clinical ultrasound imaging system. A miniature fiber-optic ultrasound hydrophone was integrated into a 20 gauge injection needle tip to receive transmissions from individual transducer elements of the ultrasound imaging probe. The received signals were reconstructed to create an image of the needle tip. Ultrasound B-mode imaging was interleaved with needle tip imaging. A first set of measurements was acquired in water and tissue ex vivo with a wide range of insertion angles (15°–68°) to study the accuracy and sensitivity of the tracking method. A second set was acquired in an in vivo swine model, with needle insertions to the brachial plexus. A third set was acquired in an in vivo ovine model for fetal interventions, with insertions to different locations within the uterine cavity. Two linear ultrasound imaging probes were used: a 14–5 MHz probe for the first and second sets, and a 9–4 MHz probe for the third. Results: During insertions in tissue ex vivo and in vivo, the imaged needle tip had submillimeter axial and lateral dimensions. The signal-to-noise (SNR) of the needle tip was found to depend on the insertion angle. With the needle tip in water, the SNR of the needle tip varied with insertion angle, attaining values of 284 at 27° and 501 at 68°. In swine tissue ex vivo, the SNR decreased from 80 at 15° to 16 at 61°. In swine tissue in vivo, the SNR varied with depth, from 200 at 17.5 mm to 48 at 26 mm, with a constant insertion angle of 40°. In ovine tissue in vivo, within the uterine cavity, the SNR varied from 46.4 at 25 mm depth to 18.4 at 32 mm depth, with insertion angles in the range of 26°–65°. Conclusions: A fiber-optic ultrasound receiver integrated into the needle cannula in combination with single-element transmissions from the imaging probe allows for direct visualization of the needle tip within the ultrasound imaging plane. Visualization of the needle tip was achieved at depths and insertion angles that are encountered during nerve blocks and fetal interventions. The method presented in this paper has strong potential to improve the safety and efficiency of ultrasound-guided needle insertions.

60 APPLIED LIFE SCIENCES↗

Metallic and porous Ti nanorod arrays for visible-IR light absorption and dendrite-free stable lithium-metal batteries

It is still a challenging task to prepare highly porous nanorod arrays of metals formed on substrates for optical and energy storage applications. Herein, we demonstrate the design and synthesis of black color, metallic and highly porous Ti nanorod arrays as novel current collectors for dendrite-free and highly stable Li-metal anodes. The high porosity of metallic nanorod arrays provides numerous heterogeneous nucleation sites and huge contact area and large space for the accommodation of Li metal. The conductive metallic Ti nanorod arrays enhance electrode integration. Effectively, it eliminates formation Li dendrites and demonstrates superior cycling stability over 300 cycles. Additionally, the unique porous structures of the nanorod arrays can decrease the amplitude of forced vibration in narrow space leading to light absorption. Interestingly, the metal is black instead of metallic color. The black metallic nanorod arrays can absorb more than 96% of both visible and infra-red lights. Furthermore, this black color metallic porous nanorod arrays may find additional applications in aerospace, energy, biomedical, defence, and chemical industries.

25 ENERGY STORAGE↗

WE-AB-BRB-01: Memorial Introduction; Storage Phosphor Panels for Radiation Therapy Dosimetry

Despite widespread IMRT treatments at modern radiation therapy clinics, precise dosimetric commissioning of an IMRT system remains a challenge. In the most recent report from the Radiological Physics Center (RPC), nearly 20% of institutions failed an end-to-end test with an anthropomorphic head and neck phantom, a test that has rather lenient dose difference and distance-to-agreement criteria of 7% and 4 mm. The RPC report provides strong evidence that IMRT implementation is prone to error and that improved quality assurance tools are required. At the heart of radiation therapy dosimetry is the multidimensional dosimeter. However, due to the limited availability of water-equivalent dosimetry materials, research and development in this important field is challenging. In this session, we will review a few dosimeter developments that are either in the laboratory phase or in the pre-commercialization phase. 1) Radiochromic plastic. Novel formulations exhibit light absorbing optical contrast with very little scatter, enabling faster, broad beam optical CT design. 2) Storage phosphor. After irradiation, the dosimetry panels will be read out using a dedicated 2D scanning apparatus in a non-invasive, electro-optic manner and immediately restored for further use. 3) Liquid scintillator. Scintillators convert the energy from x-rays and proton beams into visible light, which can be recorded with a scientific camera (CCD or CMOS) from multiple angles. The 3D shape of the dose distribution can then be reconstructed. 4) Cherenkov emission imaging. Gated intensified imaging allows video-rate passive detection of Cherenkov emission during radiation therapy with the room lights on. Learning Objectives: To understand the physics of a variety of dosimetry techniques based upon optical imaging To investigate the strategies to overcome respective challenges and limitations To explore novel ideas of dosimeter design Supported in part by NIH Grants R01CA148853, R01CA182450, R01CA109558. Brian Pogue is founder and president of the company DoseOptics LLC, dedicated to developing and commercializing the first dedicated Cerenkov imaging camera and system for radiation dose imaging. Work reported in this talk does not involve the use of DoseOptics technology.; H. Li, this work was supported in part by NIH Grant No. R01CA148853; S. Beddar, NIH funding R01-CA182450.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRB-02: Methods and Applications of 3D Radiochromic Dosimetry

Despite widespread IMRT treatments at modern radiation therapy clinics, precise dosimetric commissioning of an IMRT system remains a challenge. In the most recent report from the Radiological Physics Center (RPC), nearly 20% of institutions failed an end-to-end test with an anthropomorphic head and neck phantom, a test that has rather lenient dose difference and distance-to-agreement criteria of 7% and 4 mm. The RPC report provides strong evidence that IMRT implementation is prone to error and that improved quality assurance tools are required. At the heart of radiation therapy dosimetry is the multidimensional dosimeter. However, due to the limited availability of water-equivalent dosimetry materials, research and development in this important field is challenging. In this session, we will review a few dosimeter developments that are either in the laboratory phase or in the pre-commercialization phase. 1) Radiochromic plastic. Novel formulations exhibit light absorbing optical contrast with very little scatter, enabling faster, broad beam optical CT design. 2) Storage phosphor. After irradiation, the dosimetry panels will be read out using a dedicated 2D scanning apparatus in a non-invasive, electro-optic manner and immediately restored for further use. 3) Liquid scintillator. Scintillators convert the energy from x-rays and proton beams into visible light, which can be recorded with a scientific camera (CCD or CMOS) from multiple angles. The 3D shape of the dose distribution can then be reconstructed. 4) Cherenkov emission imaging. Gated intensified imaging allows video-rate passive detection of Cherenkov emission during radiation therapy with the room lights on. Learning Objectives: To understand the physics of a variety of dosimetry techniques based upon optical imaging To investigate the strategies to overcome respective challenges and limitations To explore novel ideas of dosimeter design Supported in part by NIH Grants R01CA148853, R01CA182450, R01CA109558. Brian Pogue is founder and president of the company DoseOptics LLC, dedicated to developing and commercializing the first dedicated Cerenkov imaging camera and system for radiation dose imaging. Work reported in this talk does not involve the use of DoseOptics technology.; H. Li, this work was supported in part by NIH Grant No. R01CA148853; S. Beddar, NIH funding R01-CA182450.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRB-03: Real-Time Volumetric Scintillation Dosimetry for Radiation Therapy

Despite widespread IMRT treatments at modern radiation therapy clinics, precise dosimetric commissioning of an IMRT system remains a challenge. In the most recent report from the Radiological Physics Center (RPC), nearly 20% of institutions failed an end-to-end test with an anthropomorphic head and neck phantom, a test that has rather lenient dose difference and distance-to-agreement criteria of 7% and 4 mm. The RPC report provides strong evidence that IMRT implementation is prone to error and that improved quality assurance tools are required. At the heart of radiation therapy dosimetry is the multidimensional dosimeter. However, due to the limited availability of water-equivalent dosimetry materials, research and development in this important field is challenging. In this session, we will review a few dosimeter developments that are either in the laboratory phase or in the pre-commercialization phase. 1) Radiochromic plastic. Novel formulations exhibit light absorbing optical contrast with very little scatter, enabling faster, broad beam optical CT design. 2) Storage phosphor. After irradiation, the dosimetry panels will be read out using a dedicated 2D scanning apparatus in a non-invasive, electro-optic manner and immediately restored for further use. 3) Liquid scintillator. Scintillators convert the energy from x-rays and proton beams into visible light, which can be recorded with a scientific camera (CCD or CMOS) from multiple angles. The 3D shape of the dose distribution can then be reconstructed. 4) Cherenkov emission imaging. Gated intensified imaging allows video-rate passive detection of Cherenkov emission during radiation therapy with the room lights on. Learning Objectives: To understand the physics of a variety of dosimetry techniques based upon optical imaging To investigate the strategies to overcome respective challenges and limitations To explore novel ideas of dosimeter design Supported in part by NIH Grants R01CA148853, R01CA182450, R01CA109558. Brian Pogue is founder and president of the company DoseOptics LLC, dedicated to developing and commercializing the first dedicated Cerenkov imaging camera and system for radiation dose imaging. Work reported in this talk does not involve the use of DoseOptics technology.; H. Li, this work was supported in part by NIH Grant No. R01CA148853; S. Beddar, NIH funding R01-CA182450.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRB-04: Cherenkov Imaging for Radiation Therapy Dose Verification On Patients

Despite widespread IMRT treatments at modern radiation therapy clinics, precise dosimetric commissioning of an IMRT system remains a challenge. In the most recent report from the Radiological Physics Center (RPC), nearly 20% of institutions failed an end-to-end test with an anthropomorphic head and neck phantom, a test that has rather lenient dose difference and distance-to-agreement criteria of 7% and 4 mm. The RPC report provides strong evidence that IMRT implementation is prone to error and that improved quality assurance tools are required. At the heart of radiation therapy dosimetry is the multidimensional dosimeter. However, due to the limited availability of water-equivalent dosimetry materials, research and development in this important field is challenging. In this session, we will review a few dosimeter developments that are either in the laboratory phase or in the pre-commercialization phase. 1) Radiochromic plastic. Novel formulations exhibit light absorbing optical contrast with very little scatter, enabling faster, broad beam optical CT design. 2) Storage phosphor. After irradiation, the dosimetry panels will be read out using a dedicated 2D scanning apparatus in a non-invasive, electro-optic manner and immediately restored for further use. 3) Liquid scintillator. Scintillators convert the energy from x-rays and proton beams into visible light, which can be recorded with a scientific camera (CCD or CMOS) from multiple angles. The 3D shape of the dose distribution can then be reconstructed. 4) Cherenkov emission imaging. Gated intensified imaging allows video-rate passive detection of Cherenkov emission during radiation therapy with the room lights on. Learning Objectives: To understand the physics of a variety of dosimetry techniques based upon optical imaging To investigate the strategies to overcome respective challenges and limitations To explore novel ideas of dosimeter design Supported in part by NIH Grants R01CA148853, R01CA182450, R01CA109558. Brian Pogue is founder and president of the company DoseOptics LLC, dedicated to developing and commercializing the first dedicated Cerenkov imaging camera and system for radiation dose imaging. Work reported in this talk does not involve the use of DoseOptics technology.; H. Li, this work was supported in part by NIH Grant No. R01CA148853; S. Beddar, NIH funding R01-CA182450.

60 APPLIED LIFE SCIENCES↗

Waterproof AlInGaP optoelectronics on stretchable substrates with applications in biomedicine and robotics

Inorganic light-emitting diodes and photodetectors represent important, established technologies for solid-state lighting, digital imaging and many other applications. Eliminating mechanical and geometrical design constraints imposed by the supporting semiconductor wafers can enable alternative uses in areas such as biomedicine and robotics. Here we describe systems that consist of arrays of interconnected, ultrathin inorganic light-emitting diodes and photodetectors configured in mechanically optimized layouts on unusual substrates. Light-emitting sutures, implantable sheets and illuminated plasmonic crystals that are compatible with complete immersion in biofluids illustrate the suitability of these technologies for use in biomedicine. Waterproof optical-proximity-sensor tapes capable of conformal integration on curved surfaces of gloves and thin, refractive-index monitors wrapped on tubing for intravenous delivery systems demonstrate possibilities in robotics and clinical medicine. Furthermore, these and related systems may create important, unconventional opportunities for optoelectronic devices.

36 MATERIALS SCIENCE↗

NASA spinoffs to bioengineering and medicine

Through the active transfer of technology, the National Aeronautics and Space Administration (NASA) Technology Utilization (TU) Program assists private companies, associations, and government agencies to make effective use of NASA's technological resources to improve U.S. economic competitiveness and to provide societal benefit. Aerospace technology from areas such as digital image processing, space medicine and biology, microelectronics, optics and electrooptics, and ultrasonic imaging have found many secondary applications in medicine. Examples of technology spinoffs are briefly discussed to illustrate the benefits realized through adaptation of aerospace technology to solve health care problems. Successful implementation of new technologies increasingly requires the collaboration of industry, universities, and government, and the TU Program serves as the liaison to establish such collaborations with NASA. NASA technology is an important resource to support the development of new medical products and techniques that will further advance the quality of health care available in the U.S. and worldwide.

Biomedical Engineering/instrumentation/trends↗

Silicon nanoparticle-functionalized fiberglass pads for sampling

We used wet treatment to immobilize luminescent silicon nanoparticles on industrial glass fibers to impart optical and chemical functions to the fiber. Carpets or pads consisting of thousands of fibers are processed in parallel, enhancing the sensitivity of detection and the sampled volume. Treated pads exhibit strong luminescence, characteristic of the luminescence of the particles; showing no shift, broadening, or reduction of quantum efficiency. We demonstrate that drawing material by the pad due to physical adsorption can be reversed. We also demonstrate that allylamine can be covalently attached by photoinduced irradiation reactions, which results in imprinting the amine emission spectrum, providing spectral recognition. The imprint accompanied with a blue-shifting of the luminescence spectrum of the probe, allowing examination of the effect of termination on the nanoparticle structure. The shift is found to be consistent with an increase in the bandgap of the Si nanoparticle and is consistent with Quantum Monte Carlo calculations. In addition to sampling, the nano probe pad has the potential to enable a variety of biomedical applications through subsequent attachment.

36 MATERIALS SCIENCE↗

Femtosecond wavelength-tunable laser system using gain managed nonlinear amplifier

Optical parametric amplifiers require a seed energy at the spectral range of interest for amplification. In the case of pulsed laser systems, seed pulse characteristics such as spectral energy density and spectral uniformity influence laser system design and performance. In this letter, we present the design and modeling of a few micro-joules, wavelength-tunable, femtosecond parametric amplifier system. We employ a gain-managed nonlinear fiber amplifier output as the seed pulse. This seed pulse is relatively uniform across its bandwidth from 1010 to 1180 nm. Its spectral energy density averages 600 pJ/nm, 30 times higher than conventional counterparts. The overall amplification gain is 175, and the conversion efficiency is 17.5%. The inherent quasi-linear chirp of the seed pulse is utilized to alter the output wavelength. Our tunable femtosecond laser is an enabling technology for high-demand applications such as time-resolved spectroscopy, nonlinear and advanced material research, and biomedical imaging and microscopy modalities.

47 OTHER INSTRUMENTATION↗

NASA Open Science Data Repository: Biomedical FAIR Data, Analysis Tools, User Communities, and Discoveries for Deep Space Missions

Increased biomedical risks and challenges associated with deep space missions require new knowledge discovery, new health countermeasures, and development of novel ecosystems, life support, crop production, and biomedical support capabilities. To meet NASA’s Moon to Mars strategic program goals for Human and Biological Sciences, findable, accessible, interoperable, reusable (FAIR), and maximally open-access data is going to be required to enable humanity to thrive in deep space. Indeed, this cornerstone perspective on FAIR and maximally open access data was also recommended in the recent 2023-2032 Decadal Survey from the National Academies of Sciences, Engineering, and Medicine. The NASA Open Science Data Repository (OSDR) is a maximally open access and FAIR database, and meets various scientific, technical, and operational spaceflight needs. It offers public users and submitters the ability to upload, download, search, share, analyze, and visualize data across ‘omics, physiological, phenotypic, behavioral, bioimaging, video, and environmental monitoring telemetry datasets. OSDR includes NASA GeneLab, NASA Ames Life Sciences Data Archive, and the NASA Biological Institutional Scientific Collection. OSDR has >455 studies with datasets from model organisms and non-NASA human astronauts. There are ~12 datasets from the Inspiration 4 (I4) mission, spanning metagenomics, comprehensive metabolic panels, clonal hematopoiesis, spatial transcriptomics, proteomics, and cytokine panels. In the interest of data privacy, two I4 datasets have raw FASTQ and FASTA files relating to the epitranscriptome, and a new request feature is live in OSDR (with a backend review process established) which was developed based on industry norms. OSDR also recently began a collaboration with the European Space Agency (ESA) to scientifically curate and make available >200 terabytes of human and model organism space-relevant data. The OSDR submission portal is designed to ingest and curate ~25 ‘omics assay data types, and ~50 physiological-phenotypic-imaging assay data types, spanning ultrasonography, micro-computed tomography, histology, morphometric photography, rebound tonometry, gait analysis, optical coherence tomography, novel object recognition, flow cytometry, and immunohistochemistry. A suite of analysis tools are available for OSDR users including: 1) an Environmental Data Application to compare radiation, CO2, relative humidity, temperature, and other telemetry across missions and subjects, 2) the RadLab database, a collaboration between NASA, ESA, the German and Italian Space Agencies, and the Bulgarian Academy of Sciences, which compiles radiation measurements relevant to human spaceflight and provides tools for accessing and manipulating the data, and 3) a Multi-study visualization tool which enables users to look across and combine GeneLab’s omics datasets across different experiments and missions. There are ~600 volunteer OSDR Analysis Working Group (AWG) members who: 1) provide feedback on scientific standards for reuse (subject and assay metadata; processing pipelines; dataset formats and uniformed structures for machine-readability), and 2) collaborate to mine-reuse OSDR data conducting scientific analysis. OSDR has enabled 60 publications as of September 2023, many directly from AWG collaborations most notably the Cell Press package in 2020. Lastly, there are at least 15 articles which mine OSDR data part of a package of ~50 articles across Nature Portfolio with research stemming from I4, the Japan Aerospace Exploration Agency, NASA Space Biology, and the NASA Human Research Program.

open access↗

Hybrid quantitative simulation on the in-line phase-contrast x-ray imaging of three dimensional samples under actual clinic imaging parameters

A hybrid model combining Monte Carlo method with diffraction theory of wave optics has been developed and applied to quantitatively simulate the in-line diffractive phase-contrast x-ray imaging of three dimensional tissue samples under actual clinic imaging parameters. The primary microcosmic interactions of medical-energy x-ray within matter including photoabsorption, Compton scattering, and coherent scattering, have been taken into account in the Monte Carlo simulation. A diffraction processing based on Fresnel diffraction theory is carried out to simulate the macroscopic diffraction effect. A comparison with experiment results has also been performed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-583: Comparison of EBT3 Radiochromic Film Densitometry with Narrow Bandwidth LED Source in Point, Slot and Full Aperture Geometries

Purpose: Film densitometers optimized for radiochromic EBT3 film are not commercially available and flatbed document scanners are limited by broad spectral overlap of the red green and blue channels and polarization effects. Non-polarized, narrow bandwith, intensity stabilized light emitting diode (LED) light sources were constructed and transmission measurements compared for point, slot and full aperture geometries. Methods: LED’s with 10 nm bandwidths were focused to 1 mm spots for point scanning. The LED’s back-illuminated a 6 mm diameter diffuser near the focal point of a 25 cm diameter Fresnel lens for slot and full aperture transmission imaging. Films were located at the aperture plane, 15 cm from the lens and imaged with a 16 bit digital camera with 50 mm lens. Sheets, 10×8 cm, were irradiated to 25 Gy with a 4×4 cm 6 MV photon beam. Transmission measurements with a 633nm, linearly polarized laser were used as lowacceptance angle reference geometry. Results: LED intensity stabilized to <1% within one minute of startup. The useful transmission range increased as the acceptance angle decreased, laser(∼2%)> spot(∼3%)> slot(∼5%)> full aperture(∼10%). The Fresnel lens introduced a 4-fold polarization symmetry that increased radially causing a 2% change in transmission at 10 cm from the optic axis for EBT3 film. Polarized spot densitometer and laser transmission were similar. Conclusion: Spectrally filtered LED sources were effective for transmission measurements of radiochromic films. Because of polarization sensitivity of EBT3 film, the scanning spot geometry is the most general for measuring unpolarised transmission of larger film sizes, ie > 15×15 cm. Due to EBT3 film scatter, spot scanning should provide the most accurate profiles of high dose gradients, for a given acceptance angle. The spot scanning densitometer provided useful transmission to ∼5, 25, >25 Gy with 635, 590 and 530 nm light respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗