Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Biomarker”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Maghemite Formation via Organics and the Prospect for Maghemite as a Biomarker Mineral on Mars

One of the major questions on Mars is the origin of the magnetic component in the surface material. Our work on maghemite formation suggests that alteration of femhydrite in the presence of organics would provide a plausible formation scenario for this magnetic soil component and further suggests that maghemite might be an important biomarker mineral on Mars. Identification of biomarker minerals is an important aspect of Astrobiology . The iron oxide mineral maghemite is thought to be one of the magnetic components in the Martian surface material; however, it is a rare mineral on the Earth and requires a reducing agent for synthesis. Organic material serves as a reductant in maghemite formation during forest fires on Earth and may play an important role in maghemite formation on Mars through low-temperature heating (e.g., volcanism, impacts). This study involves analysis of magnetite, maghemite and hematite formation under Martian environmental conditions from femhydrite in the presence and absence of organics. A dehydrated version of the mineral femhydrite is thought to be present in Martian soil/dust grains and could have formed at an earlier time on Mars when water was present. Our work indicates that low-temperature alteration of femhydrite in the presence of organic material could be an important mechanism on Mars.

Bishop, Janice↗

Analysis of complex-type chromosome exchanges in astronauts' lymphocytes after space flight as a biomarker of high-LET exposure

High-LET radiation is more efficient in producing complex-type chromosome exchanges than sparsely ionizing radiation, and this can potentially be used as a biomarker of radiation quality. To investigate if complex chromosome exchanges are induced by the high-LET component of space radiation exposure, damage was assessed in astronauts' blood lymphocytes before and after long duration missions of 3-4 months. The frequency of simple translocations increased significantly for most of the crewmembers studied. However, there were few complex exchanges detected and only one crewmember had a significant increase after flight. It has been suggested that the yield of complex chromosome damage could be underestimated when analyzing metaphase cells collected at one time point after irradiation, and analysis of chemically-induced PCC may be more accurate since problems with complicated cell-cycle delays are avoided. However, in this case the yields of chromosome damage were similar for metaphase and PCC analysis of astronauts' lymphocytes. It appears that the use of complex-type exchanges as biomarker of radiation quality in vivo after low-dose chronic exposure in mixed radiation fields is hampered by statistical uncertainties.

manned↗

Microscopic physical biomarkers in carbonate hot springs: implications in the search for life on Mars

Physical evidence of life (physical biomarkers) from the deposits of carbonate hot springs were documented at the scale of microorganisms--submillimeter to submicrometer. The four moderate-temperature (57 to 72 degrees C), neutral pH springs reported on in this study, support diverse communities of bacteria adapted to specific physical and chemical conditions. Some of the microbes coexist with travertine deposits in endolithic communities. In other cases, the microbes are rapidly coated and destroyed by precipitates but leave distinctive mineral fabrics. Some microbes adapted to carbonate hot springs produce an extracellular polymeric substance which forms a three-dimensional matrix with living cells and cell remains, known as a biofilm. Silicon and iron oxides often coat the biofilm, leading to long-term preservation. Submicrometer mineralized spheres composed of calcium fluoride or silica are common in carbonate hot spring deposits. Sphere formation is biologically mediated, but the spheres themselves are apparently not fossils or microbes. Additionally, some microbes selectively weather mineral surfaces in distinctive patterns. Hot spring deposits have been cited as prime locations for exobiological exploration of Mars. The presence of preserved microscopic physical biomarkers at all four sites supports a strategy of searching for evidence of life in hot spring deposits on Mars.

NASA Center JSC↗

The Role of Radiation in Making Meteoritic Organics and False Biomarkers

The tons of organic material that come to the Earth every day on meteorites and dust particles probably helped to make the Earth habitable, and possibly played a role in the origin of life. These compounds."include amino acids, nucleo bases, vesicle forming fatty acids, and many others. Lab experiments suggest that low temperature radiation chemistry could account for many of these chemicals. If we find evidence of Life elsewhere in the Solar System it will probably be in form of chemical biomarkers, quintessentially biological molecules that indicate the presence of micro-organisms. While most people think of the molecules above as good biomarkers, they are not.

Bernstein, Max↗

Biomarker for Space Radiation Risk: Painting Analysis of Chromosome Aberrations Induced by Energetic Heavy Ions in Human Cells

Energetic heavy ions pose a great health risk to astronauts in extended ISS and future Lunar and Mars missions. High-LET heavy ions are particularly effective in causing various biological effects, including cell inactivation, genetic mutations, cataracts and cancer induction. Most of these biological endpoints are closely related to chromosomal damage, which can be utilized as a biomarker for radiation insults. Over the years, we have studied chromosomal damage in human fibroblast, epithelia and lymphocyte cells exposed in vitro to energetic charged particles generated at several accelerator facilities in the world. We have also studied chromosome aberrations in astronaut s peripheral blood lymphocytes before and after space flight. Various fluorescence in situ hybridization painting techniques have been used to identify from only the telomere region of the chromosome to every chromosome in a human cell. We will summarize the results of the investigations, and discuss the unique radiation signatures and biomarkers for space radiation exposure.

Hada, Megumi↗

Hydrocyclone/Filter for Concentrating Biomarkers from Soil

The hydrocyclone-filtration extractor (HFE), now undergoing development, is a simple, robust apparatus for processing large amounts of soil to extract trace amounts of microorganisms, soluble organic compounds, and other biomarkers from soil and to concentrate the extracts in amounts sufficient to enable such traditional assays as cell culturing, deoxyribonucleic acid (DNA) analysis, and isotope analysis. Originally intended for incorporation into a suite of instruments for detecting signs of life on Mars, the HFE could also be used on Earth for similar purposes, including detecting trace amounts of biomarkers or chemical wastes in soils.

Ponce, Adrian↗

Organic Biomarker-Based Assays to Evaluate Total Bioburden and Organic Compounds on Space Flight Hardware

Meeting planetary protection (PP) requirements for space flight hardware may involve bioburden reduction by dry heat microbial reduction (DHMR). The NASA standard assay to demonstrate the reduction of organisms involves the swabbing of surfaces, heat shock of the extracted samples, plating of the samples on Trypticase Soy Agar (TSA), and counting colony forming units after an incubation period. The standard assay uses enumeration of heat tolerant spore-formers as a proxy for total bioburden and is generally expected to provide a lower limit. We suggest that a better estimate of the total bioburden could be obtained through sampling and analysis of organic biomarkers. As biological organisms are fundamentally organic in chemistry (i.e. carbon containing materials) it is important to characterize the biomarker compounds that are released from organisms that 1) exist on flight hardware before microbial reduction and 2) left behind from the killed organisms following microbial reduction.

Locke, Darren R.↗

Assessing the Relationships Between Sensorimotor Biomarkers and Post-Landing Functional Task Performance

Spaceflight drives adaptive changes in healthy individuals appropriate for sensorimotor function in a microgravity environment. These changes are maladaptive for return to earth's gravity. The inter-individual variability of sensorimotor decrements is striking, although poorly understood. The goal of this study is to identify a set of behavioral, neuroimaging and genetic measures that can be used to predict early post-flight performance on a set of sensorimotor tasks. Astronauts are recruited who previously participated in sensorimotor field tests and/or posturography soon after long-duration spaceflight. Behavioral tests include assessments of sensory dependency and adaptability. Visual dependency involves treadmill walking while viewing a moving virtual visual scene. Vestibular thresholds are measured while seated during lateral translations. Proprioception dependency is measured during one-legged stance on a horizontal air-bearing surface. Ground assessment of adaptability is performed (1) during treadmill walking with a virtual linear hallway and a moving walking surface, and (2) during multiple trials of navigating an obstacle course while wearing reversing prisms. The neuroimaging tests will characterize individual differences in regional brain volumes (using Structural MRI) and white matter microstructure (using Diffusion Tensor Imaging) to serve as potential predictors of adaptive capacity. The genetic tests will utilize saliva samples to examine variations in four genes chosen because of their ability to differentiate sensorimotor adaptation ability in a normative population, including Catechol-O-methyltransferase (COMT), Dopamine Receptor D2 (DRD2), Brain-derived neurotrophic factor (BDNF) and the α2-adrenergic receptor. Twenty-one ISS crewmembers have been tested to date, including 6 from this past year after testing resumed post-COVID. This cohort includes 9 first-time fliers, 4F, and mission durations lasting 182 ± 32 days, mean ± std. We are utilizing a combination of three post-flight functional task outcomes: tandem walk, recovery from fall and dynamic posturography. There is considerable variability among the post-flight performance outcomes for the 21 participants to date. Based on a partial sample using an ordinal scale survey, 80% indicated their ability to perform functional tasks were more impacted postflight relative to inflight with 50% indicating they needed to restrict movements for a longer period postflight relative to inflight. While there is a strong association within tests obtained at different R+0 timepoints, by R+24 hr performance on one post-flight test does not necessarily correlate with performance on other post-flight tests. There are apparent relationships between individual measures and specific post-flight outcome measures; however, additional data is needed to draw conclusions. Preliminary statistical analysis indicates combining biomarkers will increase predictive power and this will be explored with future analyses. Our preliminary findings underscore the importance of a comprehensive post-flight test battery including different types of tasks with varying sensory feedback. We expect that understanding the relationships between these sensorimotor biomarkers and post-flight functional task performance will improve both our understanding of the individual variability and our strategy to optimize sensorimotor countermeasures.

S J Wood↗

Assessing the Relationships Between Sensorimotor Biomarkers and Post-Landing Functional Task Performance

Spaceflight drives adaptive changes in healthy individuals appropriate for sensorimotor function in a microgravity environment. These changes are maladaptive for return to earth's gravity. The inter-individual variability of sensorimotor decrements is striking, although poorly understood. The goal of this study is to identify a set of behavioral, neuroimaging and genetic measures that can be used to predict early post-flight performance on a set of sensorimotor tasks. Astronauts are recruited who previously participated in sensorimotor field tests and/or posturography soon after long-duration spaceflight. Behavioral tests include assessments of sensory dependency and adaptability. Visual dependency involves treadmill walking while viewing a moving virtual visual scene. Vestibular perceptual thresholds are measured while seated during lateral translations. Proprioception dependency is measured during one-legged stance on a horizontal air-bearing surface. Ground assessment of adaptability is performed(1) during treadmill walking with a virtual linear hallway and a moving walking surface, and (2) during multiple trials of navigating an obstacle course while wearing reversing prisms(adaptive Functional Mobility Test, aFMT). The neuroimaging tests will characterize individual differences in regional brain volumes (using Structural MRI) and white matter microstructure(using Diffusion Tensor Imaging) to serve as potential predictors of adaptive capacity. The genetic tests will utilize saliva samples to examine variations in four genes chosen because of their ability to differentiate sensorimotor adaptation ability in a normative population, including Catechol-O-methyltransferase (COMT), Dopamine Receptor D2 (DRD2), Brain-derived neurotrophic factor (BDNF) and the α2-adrenergic receptor. Twenty-seven ISS crewmembers have been tested to date, including 6 from this past year. This cohort includes 10first-time fliers, 6F, and mission durations lasting 178.6 ± 30.5 days, mean ± std. We are utilizing a combination of three post-flight functional task outcomes: tandem walk, recovery from fall and dynamic posturography. There is considerable variability among the post-flight performance outcomes for the 27participants to date. Based on a partial sample using an ordinal scale survey, 70% indicated their ability to perform functional tasks were more impacted postflight relative to inflight with 50% indicating they needed to restrict movements for a longer period postflight relative to inflight. While there is a strong association within tests obtained at different R+0 timepoints, by R+24 hr performance on one post-flight test does not necessarily correlate with performance on other post-flight tests. There are apparent relationships between individual measures and specific post-flight outcome measures, e.g., the cumulative time to complete the aFMT is significantly correlated to pre-to-post-flight changes in tandem walk (rho= 0.64, p = 0.001). Preliminary statistical analysis indicates combining biomarkers will increase predictive power and this will be explored with future analyses. Our preliminary findings underscore the importance of a comprehensive post-flight test battery including different types of tasks with varying sensory feedback. We expect that understanding the relationships between these sensorimotor biomarkers and post-flight functional task performance will improve both our understanding of the individual variability and our strategy to optimize sensorimotor countermeasures

S J Wood↗

Oculometric Biomarkers of Visuomotor Deficits in Clinically Asymptomatic Patients With Systemic Lupus Erythematosus Undergoing Long-Term Hydroxychloroquine Treatment

Introduction: This study examines a set of oculomotor measurements, or “oculometric” biomarkers, as potential early indicators of visual and visuomotor deficits due to retinal toxicity in asymptomatic Systemic Lupus Erythematosus (SLE) patients on long-term hydroxychloroquine (HCQ) treatment. The aim is to identify subclinical functional impairments that are otherwise undetectable by standard clinical tests and to link them to structural retinal changes. Methods: We measured oculomotor responses in a cohort of SLE patients on chronic HCQ therapy using a previously established behavioral task and analysis technique. We also examined the relationship between oculometrics, OCT measures of retinal thickness, and standard clinical perimetry measures of visual function in our patient group using Bivariate Pearson Correlation and a Linear Mixed-Effects Model (LMM). Results: Significant visual and visuomotor deficits were found in 12 asymptomatic SLE patients on long-term HCQ therapy compared to a cohort of 17 age-matched healthy controls. Notably, six oculometrics were significantly different. The median initial pursuit acceleration was 22%, steady-state pursuit gain 16%, proportion smooth 7%, and target speed responsiveness 31% lower, while catch-up saccade amplitude was 46% and fixation error 46% larger. Excluding the two patients with diagnosed mild toxicity, four oculometrics, all but fixation error and proportion smooth, remained significantly impaired compared to controls. Across our population of 12 patients (24 retinae), we found that pursuit latency, initial acceleration, steady-state gain, and fixation error were linearly related to retinal thickness even when age was accounted for, while standard measures of clinical function (Mean Deviation and Pattern Standard Deviation) were not. Discussion: Our data show that specific oculometrics are sensitive early biomarkers of functional deficits in SLE patients on HCQ that could be harnessed to assist in the early detection of HCQ-induced retinal toxicity and other visual pathologies, potentially providing early diagnostic value beyond standard visual field and OCT evaluations.

eye movements↗

Biomarkers for the detection, prognois and evaluation of active tuberculosis

The global TS surveillance workshop aims to address the problems with current methods for the detection of TB, and tracking emergence of resistant strains. The purpose of the attached presentation is to review the current methods in the detection of pathogen biomarkers for TB and if that technology has promise for diagnosis of TB. A summary of three biomarkers and some data on their detection strategies is presented. Some of the work is from LANL work but much of it is derived from literature references on the subject.

60 APPLIED LIFE SCIENCES↗

Automated assessment of bilateral breast volume asymmetry as a breast cancer biomarker during mammographic screening

The biological concept of bilateral symmetry as a marker of developmental stability and good health is well established. Although most individuals deviate slightly from perfect symmetry, humans are essentially considered bilaterally symmetrical. Consequently, increased fluctuating asymmetry of paired structures could be an indicator of disease. There are several published studies linking bilateral breast size asymmetry with increased breast cancer risk. These studies were based on radiologists manual measurements of breast size from mammographic images. We aim to develop a computerized technique to assess fluctuating breast volume asymmetry in screening mammograms and investigate whether it correlates with the presence of breast cancer. Using a large database of screening mammograms with known ground truth we applied automated breast region segmentation and automated breast size measurements in CC and MLO views using three well established methods. All three methods confirmed that indeed patients with breast cancer have statistically significantly higher fluctuating asymmetry of their breast volumes. However, statistically significant difference between patients with cancer and benign lesions was observed only for the MLO views. The study suggests that automated assessment of global bilateral asymmetry could serve as a breast cancer risk biomarker for women undergoing mammographic screening. Such biomarker could be used to alert radiologists or computer-assisted detection (CAD) systems to exercise increased vigilance if higher than normal cancer risk is suspected.

Williams, Alex C↗

Multi-analyte analysis of saliva biomarkers as predictors of periodontal and pre-implant disease

The present invention relates to methods of measuring biomarkers to determine the probability of a periodontal and/or peri-implant disease. More specifically, the invention provides a panel of biomarkers that, when used in combination, can allow determination of the probability of a periodontal and/or peri-implant disease state with extremely high accuracy.

59 BASIC BIOLOGICAL SCIENCES↗

Biomarkers of high-grade serous ovarian carcinomas

The present disclosure provides biomarkers useful for determining the prognosis of conditions such as ovarian cancer. The presently disclosed subject matter provides angiogenic biomarkers and methods and compositions for predicting overall survival (OS) in women with high-grade serous carcinomas (HGSCs). The presently disclosed subject matter provides compositions and methods that enable rationally directed therapies to improve outcome in women with HGSC.

Reihani, Sharareh↗

NNA-DNA adducts as biomarkers for detecting exposure to thirdhand smoke

NNA-derived specific adducts represent an integrated biomarker of exposure to thirdhand smoke (THS) as NNA is unique to THS. The NNA-dG covalent binding adduct could serve as such a biomarker, and play a role in identifying individuals exposed to THS, thus providing critical information for early detection and prevention.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mechanism-based biomarker gene sets for glutathione depletion-related hepatotoxicity in rats

Chemical-induced glutathione depletion is thought to be caused by two types of toxicological mechanisms: PHO-type glutathione depletion [glutathione conjugated with chemicals such as phorone (PHO) or diethyl maleate (DEM)], and BSO-type glutathione depletion [i.e., glutathione synthesis inhibited by chemicals such as L-buthionine-sulfoximine (BSO)]. In order to identify mechanism-based biomarker gene sets for glutathione depletion in rat liver, male SD rats were treated with various chemicals including PHO (40, 120 and 400 mg/kg), DEM (80, 240 and 800 mg/kg), BSO (150, 450 and 1500 mg/kg), and bromobenzene (BBZ, 10, 100 and 300 mg/kg). Liver samples were taken 3, 6, 9 and 24 h after administration and examined for hepatic glutathione content, physiological and pathological changes, and gene expression changes using Affymetrix GeneChip Arrays. To identify differentially expressed probe sets in response to glutathione depletion, we focused on the following two courses of events for the two types of mechanisms of glutathione depletion: a) gene expression changes occurring simultaneously in response to glutathione depletion, and b) gene expression changes after glutathione was depleted. The gene expression profiles of the identified probe sets for the two types of glutathione depletion differed markedly at times during and after glutathione depletion, whereas Srxn1 was markedly increased for both types as glutathione was depleted, suggesting that Srxn1 is a key molecule in oxidative stress related to glutathione. The extracted probe sets were refined and verified using various compounds including 13 additional positive or negative compounds, and they established two useful marker sets. One contained three probe sets (Akr7a3, Trib3 and Gstp1) that could detect conjugation-type glutathione depletors any time within 24 h after dosing, and the other contained 14 probe sets that could detect glutathione depletors by any mechanism. These two sets, with appropriate scoring systems, could be promising biomarkers for preclinical examination of hepatotoxicity.

60 APPLIED LIFE SCIENCES↗

Improving low-level plasma protein mass spectrometry-based detection for candidate biomarker discovery and validation

Methods. To improve the detection of low abundance protein candidate biomarker discovery and validation, particularly in complex biological fluids such as blood plasma, increased sensitivity is desired using mass spectrometry (MS)-based instrumentation. A key current limitation on the sensitivity of electrospray ionization (ESI) MS is due to the fact that many sample molecules in solution are never ionized, and the vast majority of the ions that are created are lost during transmission from atmospheric pressure to the low pressure region of the mass analyzer. Two key technologies, multi-nanoelectrospray emitters and the electrodynamic ion funnel have recently been developed and refined at Pacific Northwest National Laboratory (PNNL) to greatly improve the ionization and transmission efficiency of ESI MS based analyses. Multi-emitter based ESI enables the flow from a single source (typically a liquid chromatography [LC] column) to be divided among an array of emitters (Figure 1). The flow rate delivered to each emitter is thus reduced, allowing the well-documented benefits of nanoelectrospray 1 for both sensitivity and quantitation to be realized for higher flow rate separations. To complement the increased ionization efficiency afforded by multi-ESI, tandem electrodynamic ion funnels have also been developed at PNNL, and shown to greatly improve ion transmission efficiency in the ion source interface.2, 3 These technologies have been integrated into a triple quadrupole mass spectrometer for multiple reaction monitoring (MRM) of probable biomarker candidates in blood plasma and show promise for the identification of new species even at low level concentrations.

59 BASIC BIOLOGICAL SCIENCES↗

Multichannel waveguides for the simultaneous detection of disease biomarkers

The sensor team at the Los Alamos National Laboratory has developed a waveguide-based optical biosensor that has previously been used for the detection of biomarkers associated with diseases such as tuberculosis, breast cancer, anthrax and influenza in complex biological samples (e.g., serum and urine). However, no single biomarker can accurately predict disease. To address this issue, we developed a multiplex assay for the detection of components of the Bacillus anthracis lethal toxin on single mode planar optical waveguides with tunable quantum dots as the fluorescence reporter. This limited ability to multiplex is still insufficient for accurate detection of disease or for monitoring prognosis. In this manuscript, we demonstrate for the first time, the design, fabrication and successful evaluation of a multichannel planar optical waveguide for the simultaneous detection of at least three unknown samples in quadruplicate. We demonstrate the simultaneous, rapid (30 min), quantitative (with internal standard) and sensitive (limit of detection of 1 pM) detection of protective antigen and lethal factor of Bacillus anthracis in complex biological samples (serum) using specific monoclonal antibodies labeled with quantum dots as the fluorescence reporter.

59 BASIC BIOLOGICAL SCIENCES↗