Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Beam cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Wire-coil insert optimization for high-heat-load/flux synchrotron components

Many synchrotron components require high levels of internal-flow, forced-convection heat transfer to minimize surface temperatures, thermal gradients, and thermally induced stress on high-power beam-interacting surfaces. Wire-coil inserts, physically similar to a common spring, are mechanically fitted inside of component cooling passages to optimize heat transfer performance. They are routinely used in Advanced Photon Source (APS) front end and beamline high-heat-load/flux components to significantly enhance convection heat transfer-up to 400% compared to plain open passages. This has the additional benefit of greatly reducing coolant flow requirements for these components. Using several cooling passage sizes, five different wire sizes, and a range of pitch values, an experimental investigation conducted at the APS has determined the average heat transfer coefficient and resulting pressure loss as a function of water flow rate for 65 different wire-coil inserts. Data from this study have been non-dimensionalized and generalized to yield relationships that can be used to determine the heat transfer performance and resulting pressure loss for any given wire-coil insert that may be used at the APS. Through data reduction, the wire-coil insert characteristic dimensions have also been optimized to yield the highest heat transfer enhancement while minimizing the coolant flow requirements. These generalized expressions for wirecoil inserts will be presented, and they can be used by scientists and engineers during the component design process to evaluate achievable heat transfer performance and associated pressure loss, aiding in the establishment of optimized operating parameters and cooling passage flow distribution schemes.

43 PARTICLE ACCELERATORS↗

Imaging Electrons in Two Dimensional Materials (Final report)

Two-dimensional (2D) materials have extraordinary characteristics that offer promising new approaches for science and technology. Electrons in graphene can move ballistically through a sheet, even though it is only a single atom thick. And transition metal dichalcogenide materials can be cleaved into 2D flakes of all types – metals, semiconductors, insulators, magnetic materials, and superconductors. To benefit from these discoveries, the science needs to be understood to transform 2D materials into useful new devices and systems. The evolution in time of atomic scale graphene structures has been studied in time with a transmission electron microscope (TEM), and ballistic transport of electrons in graphene was been imaged using a cooled scanning probe microscope (SPM), as well as electron motion in MoS 2 . Graphene is only one atom thick but is extremely strong, creating the opportunity to fabricate atomic scale structures in the lateral direction. Using an atomic resolution TEM, a suspended sheet of graphene can be shaped by a Si impurity atom on its surface that acts like a chisel to open up apertures, one atom at a time. The electrons in the TEM provide both the chiseling energy and the ability to image the results. Electrons and holes in graphene form a new type of electronic system with conical conduction and valence bands that meet at the Dirac point, with no energy gap. For moderate densities, the carriers form a Fermi liquid with ballistic transport over micron-scale distances. Using a cooled SPM the cyclotron orbit of electrons in graphene has been imaged. In the magnetic focusing regime, electrons leaving a point contact circle around and leave from a second point contact when the cyclotron diameter is equal to the contact spacing. The paths of electrons are focused - they enter at different angles but converge again at the exiting contact. When the SPM tip knocks an electron out of its orbit, an imaging signal is created. The ballistic motion of carriers in graphene opens the way for ballistic devices that manipulate beams of electrons and holes. Our collaborator Gil-Ho Lee, in Philip Kim's group, created a collimating contact by placing zig-zag absorbers on either side of entering electrons. Our cooled SPM was used to image the electron beam and determine its 9-degree halfwidth. By changing the gate voltage, a collimated beam of holes was also created, opening the way for colliding beam experiments. Coherent beams of carriers are desirable for quantum information processing. Via Andreev reflection, superconducting contacts can covert Cooper pairs in a superconductor to an ingoing and outgoing electrons and holes. Using our cooled SPM, Andreev reflection was imaged from a superconducting contact on a graphene device. Magnetic focusing was used to create an incoming beam of electrons and an outgoing beam of holes, detected by a third point contact. The images show a clear transition from normal reflection above the superconducting transition temperature to Andreev reflection as the device is cooled. Transition metal dichalcogenides offer a wide array of materials that can be exfoliated into ultrathin 2D sheets. A cooled SPM can be used to detect quantum dots as well as to image electron flow. The tip charge capacitively couples to electrons on the dot, acting as a gate to tune the dot conductance. Coulomb blockade peaks appear as a bullseye pattern in an SPM image as the tip is raster scanned above the dot. This approach was used to detect quantum dots in a MoS 2 channel as the carrier density was reduced and electrons pooled in low energy points. Through our DOE supported research, cooled SPM imaging has proven to be a very useful tool to uncover the motion of electrons and holes in the new quantum materials graphene and MoS 2 .

36 MATERIALS SCIENCE↗

Proton Dynamics Scenarios in the Integrable Optics Test Accelerator (IOTA) at Fermilab

The Integrable Optics Test Accelerator (IOTA) at Fermilab provides a versatile platform for studying the interplay of space-charge, impedance, and non-linear optics in high-intensity hadron beams within synchrotrons and storage rings. This report examines the parameters and dynamics of 2.5~MeV proton beam operations in two configurations of the bare IOTA lattice: one for demonstrating Non-linear Integrable Optics with the Danilov-Nagaitsev magnet, and the other for use with electron cooling. We offer order-of-magnitude estimates of the transverse emittance growth rate as a function of beam intensity, highlighting contributions from residual gas scattering, intra-beam scattering, and space-charge effects. Under nominal conditions, the beam lifetime is projected to be less than 7~minutes at low intensity with the current vacuum quality, and fewer than 100,000~turns at high intensity due to strong space-charge effects. The calculations presented here will guide strategies to mitigate emittance growth and inform future IOTA experiments.

43 PARTICLE ACCELERATORS↗

Achieving a large transverse emittance ratio in the Relativistic Heavy Ion Collider: Beam experiments, analytical estimates, and implications for the Electron-Ion Collider

The Electron-Ion Collider (EIC), to be built at Brookhaven National Laboratory, will collide a polarized high-energy electron beam with polarized proton and light ion beams in the center-of-mass energy range of 20–140 GeV, achieving a maximum peak luminosity of up to 1 × 10 34 cm − 2 s − 1 for the proton and electron collisions. To achieve such a high luminosity, the EIC will employ small, flat beams at the interaction point, which requires a transverse emittance ratio of about 11:1. Since 2017, we have carried out a series of beam experiments to test the feasibility of achieving such a large emittance ratio in the Relativistic Heavy Ion Collider (RHIC). Thanks to the existing stochastic cooling and decoupling feedback system in RHIC, we successfully demonstrated a large transverse emittance ratio of 11:1 with gold ion beams in 2023. In this article, we will present more details and data analysis for these experiments, along with analytical estimates and numerical multiparticle simulations, and provide an outlook for future EIC coupling compensation. Published by the American Physical Society 2025

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design and Prototyping of a Novel Toroid Magnet System for the MOLLER Experiment at Jefferson Lab

The Thomas Jefferson National Accelerator Facility (JLab) has designed a unique spectrometer system to measure the weak interaction between electrons. The experiment ?Measurement of Lepton-Lepton Electroweak Reaction? (MOLLER) requires leveraging the recent 12 GeV electron beam upgrade and will run in JLab for 3 years. Focusing the signal for the MOLLER experiment requires five water-cooled toroidal magnets, each with unique geometry and with 7-fold symmetry. This system of magnets provides the magnetic field required to separate the incident beam electrons scattered from the target electrons (Møller scattering) and protons (elastic e-p scattering) in a liquid hydrogen target. The conceptual design was developed by the MOLLER collaboration and was given to JLab in the form of amp turns and physical location, with additional physics requirements. This paper presents prototyping of the coils and magnet support system and discusses the lessons learned during the process along with the plans for full magnet testing and installation. The JLab Magnet Group along with the MOLLER collaboration developed the specification document that includes keep out zones to design the set of magnets. JLab contracted the design of the first toroid magnet in the magnet (TM0) to Massachusetts Institute of Technology. The other four toroid magnets (TM1 through TM4) have been designed by JLab and are in the process of fabrication and assembly. Prototype coils of TM1-TM4 have been fabricated by Everson-Tesla Incorporated, PA (USA). The manuscript presents the unique challenges of the design, alignment, high current density, operating range, high radiation dose, and vacuum environment.

Kashy, David↗

Calibrating cryogenic temperature of TEM specimens using EELS

Cryogenic Scanning/Transmission Electron Microscopy has been established as a leading method to image sensitive biological samples and is now becoming a powerful tool to understand materials' behavior at low temperatures. However, achieving precise local temperature calibration at low temperatures remains a challenge, which is especially crucial for studying phase transitions and emergent physical properties in quantum materials. In this study, we employ electron energy loss spectroscopy (EELS) to measure local cryogenic specimen temperatures. Here we use the temperature-dependent characteristics of aluminum's bulk plasmon peak in EEL spectra, which shifts due to changes in electron density caused by thermal expansion and contraction. We successfully demonstrate the versatility of this method by calibrating different liquid nitrogen cooling holders in various microscopes, regardless of whether a monochromated or non-monochromated electron beam is used. Temperature discrepancies between the actual temperature and the setpoint temperatures are identified across a range from room temperature to 100 K. This work demonstrates the importance of temperature calibrations at intermediate temperatures and presents a straightforward, robust method for calibrating local temperatures of cryogenically-cooled specimens in electron microscopes.

36 MATERIALS SCIENCE↗

Conjugate Heat Transfer Analysis in Pressurized Helium Gas Cooling Channels

Los Alamos National Laboratory (LANL) is working with NorthStar Medical Radioisotopes (NMR) on their efforts to produce Mo-99 from the irradiation of Mo-100 targets. The NMR target consists of an Inconel window that allows the electron beam to penetrate and irradiate a stack of Mo-100 disks. The irradiation process generates large amounts of heat and is cooled using pressurized helium gas flowing at 400 g/s. LANL provides both numerical analysis support and experimental support. Computational fluid dynamics (CFD) and conjugate heat transfer (CHT) analysis are performed on the NMR target to analyze the helium flow and volumetric heating through the NMR system. In this iteration of numerical analysis, we update the Mo-100 disk thickness to 0.74 mm and the gap between the Inconel window and the first disk to 0.69 mm. Estimates of the heat flux from the electron beams from Monte Carlo N-Particle code (MCNP) analysis were combined with CFD to perform the CHT analysis. The pressure drop through the targets, force applied on the first disk, beam window and target disk temperatures are some of the quantities estimated using the simulations. The pressure drop through the target was estimated as 0.198 MPa, while the force due to venturi effects across the first disk was estimated to be 100 N. The results show maximum window temperatures over 600 °C and peak disk temperatures over 1600 °C. Past work has shown that beyond 650-700 °C, the Inconel window becomes susceptible to yield and rupture. The increased temperature in these results reduces the margin of error possible on beam spot size. The disk temperatures showed a sinusoidal distribution with the 6 th – 8 th disk from each window exhibiting highest disk temperatures. The peak temperature of the stainless steel housing was close to 316 °C and that of the laminations and spacers was approximately 582 °C.

43 PARTICLE ACCELERATORS↗

Numerical Analysis and Flow Induced Vibration Studies in Pressurized Helium Gas Cooling Channels

Los Alamos National Laboratory (LANL) is working with NorthStar Medical Radioisotopes (NMR) on their efforts to produce Mo-99 from the irradiation of Mo-100 targets. The NMR target consists of an Inconel window that allows the electron beam to penetrate and irradiate a stack of Mo-100 discs. The irradiation process generates large amounts of heat and is cooled using pressurized helium gas flowing at 400 g/s. LANL provides both numerical analysis support and experimental support. Computational fluid dynamics (CFD) simulations for both 300 g/s and 400 g/s are performed on the NMR target to analyze the helium flow through the NMR system. The pressure drop, the mass flow rate through each of the disc and window channels and the force applied on the first disc are some of the quantities estimated using CFD. These results will be combined with Monte Carlo N-Particle (MCNP) estimates of heat flux into the system from the electron beam to perform conjugate heat transfer analysis (CHT). The experiments presented in this report focus on the effect of the flow induced vibrations from helium flowing through the coolant gaps between the discs. There is concern that the flow induced vibrations may lead to excessive mass loss of the enriched Mo-100 discs, and the goal would be to mitigate the mass loss. This work presents benchtop tests of flow through a subset of the target stack which involves high speed imaging and displacement measurements used to estimate disc vibration, as well as mass loss.

42 ENGINEERING↗

ULTRAFAST HIGH-VOLTAGE KICKER SYSTEM HARDWARE FOR ION CLEARING GAPS

Ionization scattering of electron beams with residual gas molecules causes ion trapping in electron rings, both in a collider and electron cooling system. These trapped ions may cause emittance growth, tune shift, halo formation, and coherent coupled bunch instabilities. To clear the ions and prevent them from accumulating turn after turn, the gaps in a temporal structure of the beam are used. Typi- cally, the gap in the bunch train has a length of a few per- cent of the ring circumference. In those regions, the extrac- tion electrodes with high pulsed voltages are introduced. In this paper, we present the design consideration and initial test results of the high-voltage pulsed kicker hardware that includes vacuum device and pulsed voltage driver, capable of achieving over 3 kV of deflecting voltage amplitude, rise and fall times of less than 10 ns, 100 ns flat-top duration at 1.4 MHz repetition rate.

Smirnov, A.↗

Remediating neutron damage in large area planar Ge-DSSD with amorphous germanium contacts through annealing and pulse-height correction

Large area, position sensitive planar germanium detectors offer new opportunities in -ray spectroscopy. For in-beam studies remediating neutron damage is important. This work studied a mechanically cooled circular planar 9 × 1 cm wafer with orthogonal 16 × 16 amorphous germanium strip electrodes. Before neutron irradiation the wafer was heated in-cryostat to above 373 K for more than 24 h in order to test the robustness of the contacts and the mechanical cooler. No deterioration in performance was observed. The detector was then exposed to controlled doses of 2.2 MeV neutrons, produced from the 7 Li(p,n) 7 Be reaction until substantial damage was observed. Averaged over the surface of the wafer, a flux of 1.9(1) x 10 9 n/cm 2 was delivered. The detector then survived thermal cycling and 350 K (~77°C) annealing for 70 h which substantially reduced hole trapping. pulse-height correction is investigated to further mitigate the neutron damage. Higher temperature annealing at 365 K was not successful.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Spectroscopic study and lifetime measurement of the 6d7p 3 F 2 o state of radium

We report a method for the precision measurement of the oscillator strengths and the branching fractions of the decay channels of the 6d7p 3 F 2 o state in 226 Ra. Here, this method exploits a set of metastable states present in Ra, allowing a measurement of the oscillator strengths that does not require knowledge of the number of atoms in the atomic beam. We measure the oscillator strengths and the branching fractions for decays from the 6d7p 3 F 2 o state to the 7s6d 3 D 1 , 7s6d 3 D 2 , and 7s6d 1 D 2 states and constrain the branching fraction to the 7s6d 3 D 3 state to be less than 0.4% (68% confidence limit). The lifetime of the 3 F 2 o state is determined to be 15 ± 4 ns.

74 ATOMIC AND MOLECULAR PHYSICS↗

Clean quantum point contacts in an InAs quantum well grown on a lattice-mismatched InP substrate

Strong spin-orbit coupling, the resulting large g factor, and small effective mass make InAs an attractive material platform for inducing topological superconductivity. The surface Fermi level pinning in the conduction band enables highly transparent ohmic contact without excessive doping. In this study, we investigate electrostatically defined quantum point contacts (QPCs) in a deep-well InAs two-dimensional electron gas. Despite the 3.3% lattice mismatch between the InAs quantum well and the InP substrate, we report clean QPCs with up to eight pronounced quantized conductance plateaus at zero magnetic field. Source-drain dc bias spectroscopy reveals a harmonic confinement potential with a nearly 5 meV subband spacing. We find a many-body exchange interaction enhancement for the out-of-plane g factor |$g^{*}_{⊥}$|=27±1 , whereas the in-plane g factor is isotropic |$g^{*}_{x}$|=|$g^{*}_{y}$|=12±2 , close to the bulk value for InAs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Determination of the $^8\mathrm{B}$ neutrino energy spectrum using trapped ions

We report the β + decay of 8 B provides the dominant source of solar neutrinos above 2 MeV. Consequently, experiments that detect neutrinos from the sun require an accurate determination of the 8 B neutrino energy spectrum. In this work, the β -decay Paul trap surrounded by double-sided silicon strip detectors was utilized to precisely measure the decay products of trapped 8 B ions. The results were used to determine the 8 Be final-state distribution and to reconstruct the neutrino energy spectrum. This measurement using trapped ions is the first of its kind and puts the neutrino energy spectrum on much firmer footing by discriminating between recently reported values for the maximum of the final-state distribution.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Longitudinal space charge kick in Coherent Electron Cooling

In recent EIC Coherent electron Cooling (CeC) design, we adopted 591 MHz SRF LINAC to accelerate electron beam to certain energy(150 MeV, 54.1 MeV and 22.3 MeV). To reduce the energy spread caused by the RF curvature, a short bunch is preferred and results in high peak current. The longitudinal space charge kick will cause the energy spread increasing and lengthen the bunch length when through the R56 elements. This slippage of modulated microbunches may misalign with hadrons providing imprinting at kicker section. In this note, we will estimate this effect and discuss possible solution.

43 PARTICLE ACCELERATORS↗

Design and Prototyping of a Novel Toroidal Magnet System for MOLLER Experiment at Jefferson Lab

The Thomas Jefferson National Accelerator Facility (JLab) has designed a unique spectrometer system to measure the weak interaction between electrons. The experiment— Measurement of Lepton-Lepton Electroweak Reaction (MOLLER)—requires leveraging the recent 12 GeV electron beam upgrade and will run in JLab for three years. Focusing the signal for the MOLLER experiment requires five water-cooled toroidal magnets, each with unique geometry and with 7-fold symmetry. The five magnets operate in a vacuum and provide the magnetic field required to separate the incident beam electrons scattered from the target electrons (Møller scattering) and protons (elastic e-p scattering) in a liquid hydrogen target. The conceptual design was developed by the MOLLER Collaboration and was given to JLab in the form of amp turns and physical location, with additional physics requirements. This article presents prototyping of the coils and magnet support system and discusses the lessons learned during the process along with the plans for full magnet testing and installation. The JLab Magnet Group along with the MOLLER Collaboration developed the specification document that includes keep out zones to design the set of magnets. JLab contracted the design of the first toroid magnet (TM0) of the magnet system to Massachusetts Institute of Technology. The other four toroid magnets (TM1 through TM4) have been designed by JLab and are in the process of fabrication and assembly. Prototype coils of TM1-TM4 were fabricated by Everson-Tesla Incorporated, PA (USA). Finally, this article presents the unique challenges of the design, alignment, high current density, operating range, high radiation dose, and vacuum environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Predicted Heat Flux Performance of Actively Cooled Tungsten-Armored Graphitic Foam Monoblocks

Tungsten (W)–armored graphitic foam monoblocks were developed for applications requiring high-Z plasma-facing material in long-pulse fusion experiments and ultimately deuterium-tritium fusion reactors. The monoblocks are an integrated material system combining the advantages of a chemical vapor deposited (CVD) W coating with a high-conductivity graphitic foam. The W is a high-melting-point, high-Z material with low tritium retention. The graphitic foam coupled to a swirl tube serves as a high-thermal-conductivity heat sink that cannot melt, although it can sublime at much higher temperatures than copper melts. Together, they comprise a robust plasma-facing component (PFC) weighing roughly 5% of an all-W component or 17% of a traditional W-coated copper heat sink.A single-channel mock-up consisting of four graphitic foam monoblocks equipped with a water-cooled swirl tube was fabricated for eventual testing in the 60-kW, EB-60, rastered electron beam at the Applied Research Laboratory of The Pennsylvania State University. Two monoblocks have a thin 50-μm-thick coating of pure W chemically vapor deposited over NbC and pure Nb interlayers. Two others have a 2-mm-thick pure W coating CVD on graphitic monoblocks using the same interlayers. The mock-up will be cooled with available 10 m/s, 0.7 MPa water with a 22°C inlet temperature and subjected to varying uniform heat loads up to 20 MW/m 2 . It is equipped with type-K thermocouples at various depths, and calibrated infrared thermography and spot pyrometry will be used to characterize the heated surface. Real-time water calorimetry will be used to ascertain the absorbed steady-state power and infer the heat flux during testing. Since testing cannot be done under prototypic divertor flow conditions, it is necessary to predict the thermal response of this novel PFC system and investigate the power sharing between radiation and convection at divertor heat flux levels and its inherent ability to avoid critical heat flux. Results are reported for predictions obtained from computational fluid dynamics models up to 30 MW/m 2 of steady-state uniform heat flux. Leading-edge heat loads of 30 MW/m 2 on a 2-mm-wide side strip were also investigated to ascertain if coating delamination is likely.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Polarized positrons at Ce\(^+\)BAF

A baseline concept for a continuous wave (CW) polarized positron injector was developed for the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab [1]. This concept is based on positron beam generation by a high current polarized electron beam (1 mA, 120 MeV, >85% polarization) irradiating a 4 mm thick rotating water-cooled tungsten target or liquid metal target. The update on the development of the Ce+BAF injector concept including the polarized electron source, the development of high power targets, simulations of positron capture, the design of the transport line from the positron injector to the CEBAF North Linac and the planned experiment to measure the upper limits of transverse and longitudinal emittances accepted by the 12 GeV CEBAF optics are presented. [1] J. Grames et al., "Positron beams at Ce+BAF", in Proc. 14th Int. Particle Accelerator Conf. (IPAC’23), Venice, Italy, MOPL152, pp. 896–899 (2023). doi:10.18429/JACoW-IPAC2023-MOPL152

Ushakov, Andriy↗

Improved calibration of rf cavities for relativistic electron beams: Effects of secondary corrections and experimental verification

In the aspect of longitudinal beam bunching, the bunching strength can be controlled by the rf cavity phase and voltage. However, these machine parameters are different from those that interact with the beam itself. In order to gain control of the beam-cavity interaction, cavity calibration must be performed. Furthermore, it relies on fitting the beam energy gain versus cavity phase to a calibration function. Under the conventional assumption of relativistic beam conditions, the calibration function is a first harmonic sinusoidal function (a sinusoidal function with a period of 2π). However, this expression is insufficient for a high-voltage bunching cavity. Due to beam acceleration inside the cavity, an energy bias and a second harmonic function should be included to modify the conventional calibration function, even for a relativistic electron beam. In this paper, we will derive this modification and provide a comparison to both the Coherent Electron Cooling Experiment and the IMPACT T simulation, respectively.

43 PARTICLE ACCELERATORS↗