Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Bayesian calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Modeling Soot Oxidation and Gasification with Bayesian Statistics

This paper presents a statistical method for model calibration using data collected from literature. The method is used to calibrate parameters for global models of soot consumption in combustion systems. This consumption is broken into two different submodels: first for oxidation where soot particles are attacked by certain oxidizing agents; second for gasification where soot particles are attacked by H 2 O or CO 2 molecules. Rate data were collected from 19 studies in the literature and evaluated using Bayesian statistics to calibrate the model parameters. Bayesian statistics are valued in their ability to quantify uncertainty in modeling. The calibrated consumption model with quantified uncertainty is presented here along with a discussion of associated implications. The oxidation results are found to be consistent with previous studies. Significant variation is found in the CO 2 gasification rates.

01 COAL, LIGNITE, AND PEAT↗

Parameterizing Bayesian network Representations of Social-Behavioral Models by Expert Elicitation

Bayesian networks provide a general framework with which to model many natural phenomena. The mathematical nature of Bayesian networks enables a plethora of model validation and calibration techniques: e.g parameter estimation, goodness of fit tests, and diagnostic checking of the model assumptions. However, they are not free of shortcomings. Parameter estimation from relevant extant data is a common approach to calibrating the model parameters. In practice it is not uncommon to find oneself lacking adequate data to reliably estimate all model parameters. In this paper we present the early development of a novel application of conjoint analysis as a method for eliciting and modeling expert opinions and using the results in a methodology for calibrating the parameters of a Bayesian network.

99 GENERAL AND MISCELLANEOUS↗

Discrete-Direct Model Calibration and Uncertainty Propagation Method Confirmed on Multi-Parameter Plasticity Model Calibrated to Sparse Random Field Data

A discrete direct (DD) model calibration and uncertainty propagation approach is explained and demonstrated on a 4-parameter Johnson-Cook (J-C) strain-rate dependent material strength model for an aluminum alloy. The methodology's performance is characterized in many trials involving four random realizations of strain-rate dependent material-test data curves per trial, drawn from a large synthetic population. The J-C model is calibrated to particular combinations of the data curves to obtain calibration parameter sets which are then propagated to “Can Crush” structural model predictions to produce samples of predicted response variability. These are processed with appropriate sparse-sample uncertainty quantification (UQ) methods to estimate various statistics of response with an appropriate level of conservatism. This is tested on 16 output quantities (von Mises stresses and equivalent plastic strains) and it is shown that important statistics of the true variabilities of the 16 quantities are bounded with a high success rate that is reasonably predictable and controllable. The DD approach has several advantages over other calibration-UQ approaches like Bayesian inference for capturing and utilizing the information obtained from typically small numbers of replicate experiments in model calibration situations—especially when sparse replicate functional data are involved like force–displacement curves from material tests. The DD methodology is straightforward and efficient for calibration and propagation problems involving aleatory and epistemic uncertainties in calibration experiments, models, and procedures.

42 ENGINEERING↗

Sensitivity-Informed Bayesian Inference for Home PLC Network Models with Unknown Parameters

Bayesian inference is used to calibrate a bottom-up home PLC network model with unknown loads and wires at frequencies up to 30 MHz. A network topology with over 50 parameters is calibrated using global sensitivity analysis and transitional Markov Chain Monte Carlo (TMCMC). The sensitivity-informed Bayesian inference computes Sobol indices for each network parameter and applies TMCMC to calibrate the most sensitive parameters for a given network topology. A greedy random search with TMCMC is used to refine the discrete random variables of the network. This results in a model that can accurately compute the transfer function despite noisy training data and a high dimensional parameter space. The model is able to infer some parameters of the network used to produce the training data, and accurately computes the transfer function under extrapolative scenarios.

42 ENGINEERING↗

Validation Metrics for Fixed Effects and Mixed-Effects Calibration

The modern scientific process often involves the development of a predictive computational model. To improve its accuracy, a computational model can be calibrated to a set of experimental data. A variety of validation metrics can be used to quantify this process. Some of these metrics have direct physical interpretations and a history of use, while others, especially those for probabilistic data, are more difficult to interpret. In this work, a variety of validation metrics are used to quantify the accuracy of different calibration methods. Frequentist and Bayesian perspectives are used with both fixed effects and mixed-effects statistical models. Through a quantitative comparison of the resulting distributions, the most accurate calibration method can be selected. Two examples are included which compare the results of various validation metrics for different calibration methods. It is quantitatively shown that, in the presence of significant laboratory biases, a fixed effects calibration is significantly less accurate than a mixed-effects calibration. This is because the mixed-effects statistical model better characterizes the underlying parameter distributions than the fixed effects model. The results suggest that validation metrics can be used to select the most accurate calibration model for a particular empirical model with corresponding experimental data.

97 MATHEMATICS AND COMPUTING↗

Validation and Calibration of Nuclear Thermal Hydraulics Multiscale Multiphysics Models - Subcooled Flow Boiling Study

In addition to validation data plan, development of advanced techniques for calibration and validation of complex multiscale, multiphysics nuclear reactor simulation codes are a main objective of the CASL VUQ plan. Advanced modeling of LWR systems normally involves a range of physico-chemical models describing multiple interacting phenomena, such as thermal hydraulics, reactor physics, coolant chemistry, etc., which occur over a wide range of spatial and temporal scales. To a large extent, the accuracy of (and uncertainty in) overall model predictions is determined by the correctness of various sub-models, which are not conservation-laws based, but empirically derived from measurement data. Such sub-models normally require extensive calibration before the models can be applied to analysis of real reactor problems. This work demonstrates a case study of calibration of a common model of subcooled flow boiling, which is an important multiscale, multiphysics phenomenon in LWR thermal hydraulics. The calibration process is based on a new strategy of model-data integration, in which, all sub-models are simultaneously analyzed and calibrated using multiple sets of data of different types. Specifically, both data on large-scale distributions of void fraction and fluid temperature and data on small-scale physics of wall evaporation were simultaneously used in this work’s calibration. In a departure from traditional (or common-sense) practice of tuning/calibrating complex models, a modern calibration technique based on statistical modeling and Bayesian inference was employed, which allowed simultaneous calibration of multiple sub-models (and related parameters) using different datasets. Quality of data (relevancy, scalability, and uncertainty) could be taken into consideration in the calibration process. This work presents a step forward in the development and realization of the “CIPS Validation Data Plan” at the Consortium for Advanced Simulation of LWRs to enable quantitative assessment of the CASL modeling of Crud-Induced Power Shift (CIPS) phenomenon, in particular, and the CASL advanced predictive capabilities, in general. This report is prepared for the Department of Energy’s Consortium for Advanced Simulation of LWRs program’s VUQ Focus Area.

97 MATHEMATICS AND COMPUTING↗

Bayesian Analysis of RANS Models

This work demonstrates the advantages of using a Bayesian framework to analyze and calibrate BHR3.1, the main mix model under development at LANL and supported by both Science Campaigns and ASC.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improved uncertainty quantification in nondestructive assay for nonproliferation

This paper illustrates methods to improve uncertainty quantification (UQ) for non-destructive assay (NDA) measurements used in nuclear nonproliferation. First, it is shown that current bottom-up UQ applied to calibration data is not always adequate, for three main reasons: (1) Because there are errors in both the predictors and the response, calibration involves a ratio of random quantities, and calibration data sets in NDA usually consist of only a modest number of samples (3–10); therefore, asymptotic approximations involving quantities needed for UQ such as means and variances are often not sufficiently accurate; (2) Common practice overlooks that calibration implies a partitioning of total error into random and systematic error, and (3) In many NDA applications, test items exhibit non-negligible departures in physical properties from calibration items, so model-based adjustments are used, but item-specific bias remains in some data. Therefore, improved bottom-up UQ using calibration data should predict the typical magnitude of item-specific bias, and the suggestion is to do so by including sources of item-specific bias in synthetic calibration data that is generated using a combination of modeling and real calibration data. Second, for measurements of the same nuclear material item by both the facility operator and international inspectors, current empirical (top-down) UQ is described for estimating operator and inspector systematic and random error variance components. A Bayesian alternative is introduced that easily accommodates constraints on variance components, and is more robust than current top-down methods to the underlying measurement error distributions.

97 MATHEMATICS AND COMPUTING↗

Robust Statistical Approach for Determination of Graphite Nitridation Using Bayesian Model Comparison

A better estimation of surface reaction efficiency of semiconductor-grade graphite with atomic nitrogen, as well as the calibration error are calculated using Bayesian updating based on experimental data. Compared with a conventional deterministic model, the stochastic model approach is a powerful tool in the sense that the model is capable of taking into account underlying error correlations among the data quantities. In this paper, we investigate four different stochastic models (called “stochastic system model classes” herein) corresponding to different descriptions of modeling and measurement error structures, given one deterministic physical model. These stochastic system model classes differ in the covariance matrix structure that is used in the uncertainty model to represent uncertainties associated with the physical model and experimental measurements. For each model class, Bayesian inference is used to estimate the posterior probabilities of the physical model parameters as well as of the stochastic model parameters. Model comparison and selection are then applied based on two measures including Bayesian evidence and Bayesian information criterion, as well as the deviance information criterion. Both measures suggest the stochastic model class, which considers that a correlation between errors in two data quantities among different data points is the most plausible. With the stochastic model class, the range of uncertainty in surface reaction efficiency is estimated to be about two orders of magnitude at [Formula: see text].

Engineering↗

Past and present cosmic structure in the SDSS DR7 main sample

We present a chrono-cosmography project, aiming at the inference of the four dimensional formation history of the observed large scale structure from its origin to the present epoch. To do so, we perform a full-scale Bayesian analysis of the northern galactic cap of the Sloan Digital Sky Survey (SDSS) Data Release 7 main galaxy sample, relying on a fully probabilistic, physical model of the non-linearly evolved density field. Besides inferring initial conditions from observations, our methodology naturally and accurately reconstructs non-linear features at the present epoch, such as walls and filaments, corresponding to high-order correlation functions generated by late-time structure formation. Our inference framework self-consistently accounts for typical observational systematic and statistical uncertainties such as noise, survey geometry and selection effects. We further account for luminosity dependent galaxy biases and automatic noise calibration within a fully Bayesian approach. As a result, this analysis provides highly-detailed and accurate reconstructions of the present density field on scales larger than ∼ 3 Mpc/h, constrained by SDSS observations. This approach also leads to the first quantitative inference of plausible formation histories of the dynamic large scale structure underlying the observed galaxy distribution. The results described in this work constitute the first full Bayesian non-linear analysis of the cosmic large scale structure with the demonstrated capability of uncertainty quantification. Some of these results will be made publicly available along with this work. The level of detail of inferred results and the high degree of control on observational uncertainties pave the path towards high precision chrono-cosmography, the subject of simultaneously studying the dynamics and the morphology of the inhomogeneous Universe.

79 ASTRONOMY AND ASTROPHYSICS↗

Improvement of two-phase closure models in CTF using Bayesian inference

Under the Consortium for Advanced Simulation of Light Water Reactors (CASL) program, extensive capabilities have been developed in CTF to analyze light-water reactors (LWRs) for normal operating conditions, departure from nucleate boiling (DNB), and system transients. However, further improvements are required in the modeling and simulation of boiling water reactors (BWRs), which is a focus of the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program. In this work, CTF validation results were used to optimize selected modeling coefficients by calibrating to experimental data using a Bayesian inference approach. Here, calibration studies were conducted to improve (vapor) void fraction prediction without worsening the two-phase pressure drop prediction, as well as to improve the two-phase pressure drop prediction. Calibration was performed for interfacial drag and wall shear models. Surrogates were developed to alleviate the computational expense required for sampling the parameter space using Markov chain Monte Carlo (MCMC). An assessment performed with calibrated models demonstrated an improvement of CTF in its prediction of key parameters such as void fraction and two-phase pressure drop.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development and evaluation of a harmonized physiologically based pharmacokinetic (PBPK) model for perchloroethylene toxicokinetics in mice, rats, and humans

This article reports on the development of a 'harmonized' PBPK model for the toxicokinetics of perchloroethylene (tetrachloroethylene or perc) in mice, rats, and humans that includes both oxidation and glutathione (GSH) conjugation of perc, the internal kinetics of the oxidative metabolite trichloroacetic acid (TCA), and the urinary excretion kinetics of the GSH conjugation metabolites N-Acetylated trichlorovinyl cysteine and dichloroacetic acid. The model utilizes a wider range of in vitro and in vivo data than any previous analysis alone, with in vitro data used for initial, or 'baseline,' parameter estimates, and in vivo datasets separated into those used for 'calibration' and those used for 'evaluation.' Parameter calibration utilizes a limited Bayesian analysis involving flat priors and making inferences only using posterior modes obtained via Markov chain Monte Carlo (MCMC). As expected, the major route of elimination of absorbed perc is predicted to be exhalation as parent compound, with metabolism accounting for less than 20% of intake except in the case of mice exposed orally, in which metabolism is predicted to be slightly over 50% at lower exposures. In all three species, the concentration of perc in blood, the extent of perc oxidation, and the amount of TCA production is well-estimated, with residual uncertainties of {approx} 2-fold. However, the resulting range of estimates for the amount of GSH conjugation is quite wide in humans ({approx} 3000-fold) and mice ({approx} 60-fold). While even high-end estimates of GSH conjugation in mice are lower than estimates of oxidation, in humans the estimated rates range from much lower to much higher than rates for perc oxidation. It is unclear to what extent this range reflects uncertainty, variability, or a combination. Importantly, by separating total perc metabolism into separate oxidative and conjugative pathways, an approach also recommended in a recent National Research Council review, this analysis reconciles the disparity between those previously published PBPK models that concluded low perc metabolism in humans and those that predicted high perc metabolism in humans. In essence, both conclusions are consistent with the data if augmented with some additional qualifications: in humans, oxidative metabolism is low, while GSH conjugation metabolism may be high or low, with uncertainty and/or interindividual variability spanning three orders of magnitude. More direct data on the internal kinetics of perc GSH conjugation, such as trichlorovinyl glutathione or tricholorvinyl cysteine in blood and/or tissues, would be needed to better characterize the uncertainty and variability in GSH conjugation in humans. - Research Highlights: >We analyze perchloroethylene (perc) toxicokinetics with a physiological model. >Results from previous analyses lumping metabolic pathways are inconsistent. >Separately tracking oxidation and conjugation pathways reconciles these results. >Available data are adequate for predicting perc blood levels and oxidation by P450. >High uncertainty remains for human conjugation of perc with glutathione.

60 APPLIED LIFE SCIENCES↗

High-resolution x-ray spectrometer for x-ray absorption fine structure spectroscopy

Two extended x-ray absorption fine structure flat crystal x-ray spectrometers (EFX’s) were designed and built for high-resolution x-ray spectroscopy over a large energy range with flexible, on-shot energy dispersion calibration capabilities. The EFX uses a flat silicon [111] crystal in the reflection geometry as the energy dispersive optic covering the energy range of 6.3–11.4 keV and achieving a spectral resolution of 4.5 eV with a source size of 50 μm at 7.2 keV. A shot-to-shot configurable calibration filter pack and Bayesian inference routine were used to constrain the energy dispersion relation to within ±3 eV. The EFX was primarily designed for x-ray absorption fine structure (XAFS) spectroscopy and provides significant improvement to the Laboratory for Laser Energetics’ OMEGA-60 XAFS experimental platform. The EFX is capable of performing extended XAFS measurements of multiple absorption edges simultaneously on metal alloys and x-ray absorption near-edge spectroscopy to measure the electron structure of compressed 3d transition metals.

47 OTHER INSTRUMENTATION↗

Practical Use of Computationally Frugal Model Analysis Methods

Computationally frugal methods of model analysis can provide substantial benefits when developing models of groundwater and other environmental systems. Model analysis includes ways to evaluate model adequacy and to perform sensitivity and uncertainty analysis. Frugal methods typically require 10s of parallelizable model runs; their convenience allows for other uses of the computational effort. We suggest that model analysis be posed as a set of questions used to organize methods that range from frugal to expensive (requiring 10,000 model runs or more). This encourages focus on method utility, even when methods have starkly different theoretical backgrounds. We note that many frugal methods are more useful when unrealistic process-model nonlinearities are reduced. Inexpensive diagnostics are identified for determining when frugal methods are advantageous. Examples from the literature are used to demonstrate local methods and the diagnostics. We suggest that the greater use of computationally frugal model analysis methods would allow questions such as those posed in this work to be addressed more routinely, allowing the environmental sciences community to obtain greater scientific insight from the many ongoing and future modeling efforts

54 ENVIRONMENTAL SCIENCES↗