Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Baseline”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

ICARUS: new voyage to sterile neutrino search in the Short Baseline Program

The ICARUS collaboration operated the 760-ton T600 detector in a successful three-year physics run at the underground LNGS laboratories studying neutrino oscillations with the CNGS neutrino beam from CERN, and searching for atmospheric neutrino interactions. ICARUS performed a sensitive search for LSND-like anomalous νe appearance in the CNGS beam, which contributed to the constraints on the allowed parameters to a narrow region around $Δm^2=1 e\text{V}^2$, where all the experimental results can be coherently accommodated at 90% C.L. After a significant overhaul at CERN, the T600 detector has been installed at Fermilab. In 2020 cryogenic commissioning began with detector cool down, liquid Argon filling and recirculation. ICARUS has started operations and is presently in its commissioning phase with the aim of collecting its first neutrino events from the Booster Neutrino Beam and the NuMI off-axis beam. The main goal of the first year of ICARUS data taking will then be the definitive verification of the recent claim by NEUTRINO-4 short baseline reactor experiment both in the $ν_μ$ channel with the BNB and in the $ν_e$ with NuMI. After the first year of operations, ICARUS will commence its search for evidence of a sterile neutrino jointly with the SBND near detector, within the Short Baseline Neutrino (SBN) program. The ICARUS exposure to the NuMI beam will also give the possibility for other physics studies such as light dark matter searches and neutrino-Argon cross section measurements. The proposed contribution addresses ICARUS achievements, its status and plans for the new run at Fermilab and the ongoing developments of the analysis tools needed to fulfill its physics program.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Host genetics and gut microbiota composition: Baseline gut microbiota composition as a possible prognostic factor for the severity of COVID-19 in patients with familial Mediterranean fever disease

It is known that the gut microbiome of a healthy person affects the process of COVID-19 after getting infected with SARS-CoV-2 virus. It is also believed that colchicine can alleviate the severity of COVID-19. Current investigations aimed to evaluate the associations between the baseline gut microbiota composition of healthy and Familial Mediterranean fever (FMF) - carrier Armenian men populations, and the severity of the COVID-19 disease after their infection with the SARS-CoV-2. The study has a purpose of answering three core questions: i. Do the characteristics of gut microbiome of Armenians affect the course of COVID-19 severity? ii. How does the COVID-19 disease course on go for FMF patients who have been taking colchicine as a medication over the years after getting infected with SARS-CoV-2? iii. Is there an initial gut micribiota structure pattern for non-FMF and FMF patients in the cases when COVID-19 appears in mild form? The gut microbiota composition in non-FMF and FMF patients before the first infection (mild and moderate course of COVID-19) was considered. COVID-19 was diagnosed by SARS-CoV-2 nucleic acid RT-PCR in nasopharyngeal swab and/or sputum. The number of patients with male FMF with mild COVID-19 was approximately two times higher than that of non-FMF male subjects with COVID-19. In addition, an association of COVID-19 disease severity with the baseline gut Prevotella, Clostridium hiranonis, Eubacterium biforme, Veillonellaceae, Coprococcus, and Blautia diversities in the non-FMF and FMF populations were revealed by us, which can be used as risk/prognostic factor for the severity of COVID-19.

60 APPLIED LIFE SCIENCES↗

A SYSTEMATIC SEARCH FOR PERIODICALLY VARYING QUASARS IN PAN-STARRS1: AN EXTENDED BASELINE TEST IN MEDIUM DEEP SURVEY FIELD MD09

We present a systematic search for periodically varying quasars and supermassive black hole binary (SMBHB) candidates in the Pan-STARRS1 (PS1) Medium Deep Survey’s MD09 field. From a color-selected sample of 670 quasars extracted from a multi-band deep-stack catalog of point sources, we locally select variable quasars and look for coherent periods with the Lomb–Scargle periodogram. Three candidates from our sample demonstrate strong variability for more than ∼3 cycles, and their PS1 light curves are well fitted to sinusoidal functions. We test the persistence of the candidates’ apparent periodic variations detected during the 4.2 years of the PS1 survey with archival photometric data from the SDSS Stripe 82 survey or new monitoring with the Large Monolithic Imager at the Discovery Channel Telescope. None of the three periodic candidates (including PSO J334.2028+1.4075) remain persistent over the extended baseline of 7–14 years, corresponding to a detection rate of <1 in 670 quasars in a search area of ≈5 deg{sup 2}. Even though SMBHBs should be a common product of the hierarchal growth of galaxies, and periodic variability in SMBHBs has been theoretically predicted, a systematic search for such signatures in a large optical survey is strongly limited by its temporal baseline and the “red noise” associated with normal quasar variability. We show that follow-up long-term monitoring (≳5 cycles) is crucial to our search for these systems.

79 ASTRONOMY AND ASTROPHYSICS↗

ALMA Band-to-band Phase Referencing: Imaging Capabilities on Long Baselines and High Frequencies

High-frequency long-baseline experiments with the Atacama Large Millimeter/submillimeter Array were organized to test the high angular resolution imaging capabilities in the submillimeter wave regime using baselines up to 16 km. Four experiments were conducted, two Band 7 (289 GHz) and two Band 8 (405 GHz) observations. Phase correction using band-to-band (B2B) phase referencing was used with a phase calibrator only [[Formula]] away observed in Band 3 (96 GHz) and Band 4 (135 GHz), respectively. In Band 8, we achieved the highest resolution of 14 × 11 mas. We compared the synthesis images of the target quasar using 20 and 60 s switching cycle times in the phase referencing. In Band 7, the atmosphere had good stability in phase rms (<0.5 rad over 2 minutes), and there was little difference in image coherence between the 20 and 60 s switching cycle times. One Band 8 experiment was conducted under a worse phase rms condition (>1 rad over 2 minutes), which led to a significantly reduced coherence when using the 60 s switching cycle time. One of our four experiments indicates that the residual phase rms error after phase referencing can be reduced to 0.16 rad at 289 GHz in using the 20 s switching cycle time. Such conditions would meet the phase correction requirement of image coherence of >70% in Band 10, assuming a similar phase calibrator separation angle, emphasizing the need for such B2B phase referencing observing at high frequencies.

79 ASTRONOMY AND ASTROPHYSICS↗

Constraining non-standard neutrino interactions with neutral current events at long-baseline oscillation experiments

We explore, for the first time, neutral-current events at long-baseline experiments to constrain vector and axial-vector neutrino non-standard interactions (NSI) with quarks. We leverage the flavor dependence of NSIs to perform an oscillation analysis in the neutral- current channel. We first introduce a framework to parametrize the effect of NSI on the cross section. Then, as an example, we analyze NOvA neutral-current data which provides significantly improved constraints on the axial-vector NSI parameters $ {\varepsilon}_{\mu \mu}^A $,$ {\varepsilon}_{\tau \tau}^A $ and $ {\varepsilon}_{e\mu}^A $. This is highly complementary to constraints from SNO data, which, differently from long-baseline neutral current data, is not sensitive to isospin conserving NSIs $ {\varepsilon}_u^A $ = $ {\varepsilon}_d^A $. Additionally, we disfavor large values of the diagonal vectorial NSI $ {\varepsilon}_{\mu \mu}^{VV} $ and $ {\varepsilon}_{\tau \tau}^V $ which originate from the LMA-Dark solution. We also highlight the complementarity between NSI searches at oscillation experiments using charged current and neutral current channels.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Baseline Climate Variables for Earth System Modelling

The Baseline Climate Variables for Earth System Modelling (ESM-BCVs) are defined as a list of 135 variables which have high utility for the evaluation and exploitation of climate simulations. The list reflects the most frequently used elements of the Coupled Model Intercomparison Project Phase 6 (CMIP6) archive. Successive phases of CMIP have supported strong results in science and substantially influence international climate policy formulation. This paper responds to both interest in exploiting CMIP data standards in a broader range of climate modelling activities and a need to achieve greater clarity about the significance and intention of variables in the CMIP Data Request. As Earth system modelling archives grow in scale and complexity, there are emerging problems associated with weak standardisation at the variable collection level. That is, there are good standards covering how specific variables should be archived, but this paper fills a gap in the standardisation of which variables should be archived. The ESM-BCV list is intended as a resource for ESM intercomparison projects (MIPs) developing requests to enable greater consistency among MIPs and as a reference for modelling centres to enhance consistency within MIPs. Provisional planning for the CMIP7 Data Request exploits the ESM-BCVs as a core element. The baseline variable list includes 98 variables which have modest or minor data volume footprints and could be generated systematically when simulations are produced and archived for exploitation by the World Climate Research Programme (WCRP) community. A further 35 variables are classed as “high volume” and are only suitable for production when the resource implications are justified.

Juckes, Martin [University of Oxford (United Kingd↗

The Fermilab Short-Baseline Program: MicroBooNE

The MicroBooNE experiment is the first of three detectors of the Fermilab short-baseline neutrino program that started operation in the Booster Neutrino Beamline in October 2015 [1]. When completed, the three-detector lineup will explore short-baseline neutrino oscillations and will be sensitive to sterile neutrino scenarios. MicroBooNE in itself is now starting its own physics program, with the measurement of neutrino-argon cross sections in the ~1GeV range being one of its main physics goals. These proceedings describe the status of the detector, the start of operation, and the automated reconstruction of the first neutrino events observed with MicroBooNE. Prospects for upcoming cross section measurements are also given.

43 PARTICLE ACCELERATORS↗

Pulse-code-modulation baseline correction for low signal-to-noise ratios

Time-shared integrate-hold-dump circuits separate the dc level due to the signal /bit information/ from the dc signal due to the baseline error. The system detects the baseline error, filters it, and then algebraically adds enough voltage to a servo loop to reduce the error to zero.

Stephens, T. J.↗

Single-stage evaluation of highly-loaded high-Mach-number compressor stages 5. Data and performance of baseline, corner-blow wall suction and combined corner blow wall suction stator

A single-stage compressor with a rotor tip speed of 1600 ft/sec and a 0.5 hub tip ratio was used to investigate the effects of several stator endwall treatment methods on stage range and performance. These endwall treatment methods consisted of stator corner-blow, annular wall suction upstream of stator leading edge, and combined corner-blow and annular wall suction. The overall stage performance with corner blow was essentially the same as the baseline performance. The performance for the annular wall suction and the combined corner-blow and wall suction showed a reduction in peak efficiency of 2.5 percentage points compared to the baseline data.

Nikkanen, J. P.↗

Very long baseline interferometry observations of radio emissions from geostationary satellites.

Review of the results of very long baseline interferometry (VLBI) observations of L-band emissions of the ATS-5 geostationary satellite, performed over a transcontinental baseline in 1970, as part of a more comprehensive program using radio stars as sources. Although the data were not sufficient to demonstrate fully the capability of the method for determining the orbital elements of a satellite and its inertial position, the analysis of the ATS observations show the presence of interference fringes related to the modulation waveform emitted by the satellite and to the various motions of the satellite. The measured VLBI time delays are in agreement with the geometry of the observations and with the instrumental delay, both determined independently.

Michelini, R. D.↗

Shuttle mission simulator baseline definition report, volume 1

A baseline definition of the space shuttle mission simulator is presented. The subjects discussed are: (1) physical arrangement of the complete simulator system in the appropriate facility, with a definition of the required facility modifications, (2) functional descriptions of all hardware units, including the operational features, data demands, and facility interfaces, (3) hardware features necessary to integrate the items into a baseline simulator system to include the rationale for selecting the chosen implementation, and (4) operating, maintenance, and configuration updating characteristics of the simulator hardware.

Burke, J. F.↗

Study of space shuttle orbiter system management computer function. Volume 1: Analysis, baseline design

A system analysis of the shuttle orbiter baseline system management (SM) computer function is performed. This analysis results in an alternative SM design which is also described. The alternative design exhibits several improvements over the baseline, some of which are increased crew usability, improved flexibility, and improved growth potential. The analysis consists of two parts: an application assessment and an implementation assessment. The former is concerned with the SM user needs and design functional aspects. The latter is concerned with design flexibility, reliability, growth potential, and technical risk. The system analysis is supported by several topical investigations. These include: treatment of false alarms, treatment of off-line items, significant interface parameters, and a design evaluation checklist. An in-depth formulation of techniques, concepts, and guidelines for design of automated performance verification is discussed.

Source record↗

Very long baseline interferometry using a communication satellite

A planned experiment is discussed in long-baseline interferometry, using the Communications Technology Satellite to transmit the base-band signal from one telescope to another for real-time correlation. A 20 megabit data rate is planned, calling for a delay-line of 10 MHz bandwidth and controllable delay up to 275 milliseconds. A number of sources will be studied on baselines from Ontario to West Virginia and California.

Swenson, G. W., Jr.↗

Transcontinental baselines and the rotation of the earth measured by radio interferometry

Nine separate very-long-baseline interferometry experiments, carried out in 1972 and 1973 with radio telescopes 3900 kilometers apart, yielded values for the baseline length with an rms deviation about the mean of less than 20 centimeters. The corresponding fractional spread is about five parts in 100,000,000. Changes in universal time and in polar motion were also determined accurately from these data. The rms scatter of these results with respect to those based on optical methods was 2.9 msec and 1.3 m, respectively. Solid-earth tides were apparently detected, but no useful estimate of their amplitude was extracted.

Shapiro, I. I.↗

Space Tug baseline description and status

The baseline definition of the Space Tug discussed herein is the one necessary to meet current payload mission model requirements in the mid-1980's for the least risk and development investment. This baseline Space Tug is a nominal 15-ft diameter, 30-ft long, LOX/LH2 stage with a main propellant capacity of about 50,000 lbs. Once deployed from the Space Shuttle in orbit, it is designed to automatically deliver spacecraft to a predetermined position and velocity and/or rendezvous and dock with prepositioned spacecraft for servicing or retrieval. The Tug would normally be returned to the vicinity of the Shuttle Orbiter, with or without spacecraft, to be retrieved and returned to earth in the Shuttle. Design characteristics, performance requirements, projected activities, and subsystems features are described.

Teir, W.↗

A very-long-baseline interferometer system for geodetic applications

A very-long-baseline interferometer system was designed and built for geodetic applications. Each interferometer terminal records a 360-kHz spectral band of noise from a compact extragalactic radio source. The center frequency of the spectral band can be selected to sample sequentially bands covering a much wider frequency range to obtain subnanosecond accuracy in group-delay measurements. A tunnel-diode pulse generator is used to calibrate the delays in the receiver. The necessary sets of algorithms and computer programs have been developed to analyze the data and have allowed the system to be employed to make accurate determinations of vector baselines, radio-source positions, polar motion, and universal time.

Whitney, A. R.↗

Ablative performance of uncoated silicone-modified and shuttle baseline reinforced carbon composites

The relative ablative performance of uncoated silicone-modified reinforced carbon composite (RCC) and uncoated shuttle baseline RCC substrates was investigated. The test specimens were 13 plies (5.3 to 5.8 millimeters) thick and had a 25-millimeter-diameter test face. Prior to arc tunnel testing, all specimens were subjected to a heat treatment simulating the RCC coating process. During arc tunnel testing, the specimens were exposed to cold wall heating rates of 178 to 529 kilowatts/sq m and stagnation pressures ranging from 0.015 to 0.046 atmosphere at Mach 4.6 in air, with and without preheating in nitrogen. The results show that the ablative performance of uncoated silicone-modified RCC substrates is significantly superior to that of uncoated shuttle baseline RCC substrates over the range of heating conditions used. These results indicate that the silicone-modified RCC substrate would yield a substantially greater safety margin in the event of complete coating loss on the shuttle orbiter.

Dicus, D. L.↗

Static and wind tunnel near-field/far field jet noise measurements from model scale single-flow baseline and suppressor nozzles. Volume 2: Forward speed effects

A model scale flight effects test was conducted in the 40 by 80 foot wind tunnel to investigate the effect of aircraft forward speed on single flow jet noise characteristics. The models tested included a 15.24 cm baseline round convergent nozzle, a 20-lobe and annular nozzle with and without lined ejector shroud, and a 57-tube nozzle with a lined ejector shroud. Nozzle operating conditions covered jet velocities from 412 to 640 m/s at a total temperature of 844 K. Wind tunnel speeds were varied from near zero to 91.5 m/s. Measurements were analyzed to (1) determine apparent jet noise source location including effects of ambient velocity; (2) verify a technique for extrapolating near field jet noise measurements into the far field; (3) determine flight effects in the near and far field for baseline and suppressor nozzles; and (4) establish the wind tunnel as a means of accurately defining flight effects for model nozzles and full scale engines.

Jaeck, C. L.↗