Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Base stations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Real-Time, Simultaneous Soil Water Content and Meteorological Data Measurement to Support TRACER over Harris County, Texas Field Campaign Report: Part II

The main purpose of this project was to provide ground-truth and satellite-based soil water content data in the Houston, Texas, area to support the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s 2022 field campaign, the Tracking Aerosol Convection Interactions ExpeRiment (TRACER). This involved installing four soil monitoring stations at different locations in the Houston area, two of which were part of the ARM facility and two were ancillary. The two stations associated directly with ARM were installed alongside other facilities managed and maintained by the TRACER research team during the intensive operational period (IOP), one located at the La Porte, Texas airport and the other located near Guy, Texas. Data from these stations were assimilated with similar data collected by the Harris County Flood Control District (HCFCD) to improve the spatial coverage of the real-time monitoring network. The ground-truth data were compared to the satellite-based (National Aeronautics and Space Administration [NASA]’s Soil Moisture Active Passive [SMAP] mission) data in the TRACER area of interest, and analyzed further to nowcast gridded data over the Houston area. The nowcasted, gridded data product was made available to TRACER researchers for use in climate and land-atmosphere interaction modeling that can help understand formation and persistence of convective storms in dense urban areas, and predict possible environmental events such as floods.

54 ENVIRONMENTAL SCIENCES↗

A multi-scale temperature-based strategy to map hydrologic exchange flows in highly dynamic systems

Mapping and quantifying hydrologic exchange flows (HEFs) is critical to environmental monitoring and remediation at contaminated sites; however, these objectives are challenging in highly dynamic systems, e.g., along dam-regulated rivers, where HEFs vary rapidly. Direct seepage measurements are labor-intensive and difficult to automate, whereas indirect (e.g., thermal) and remote sensing methods have potential to allow continuous monitoring with limited field effort. We present a preliminary assessment of a multi-scale temperature-based strategy for monitoring HEFs along the Hanford Reach of the Columbia River, in eastern WA, United States. Five thermal methods were assessed. First, a vertical temperature profile (VTP) was installed into the streambed. The VTP data were analyzed using a data assimilation algorithm designed for automated real-time estimation in dynamic systems. Second, a thermal infrared (TIR) camera was used in roving surveys to identify seeps. Third, a TIR camera was stationed at the VTP site to collect images at 1-h intervals. Together, the two TIR datasets provided a basis to assess the potential for drone-based TIR. Fourth, temperature was measured at the sediment/water interface to assess fiber-optic distributed temperature sensing. Fifth, imagery from the ECOSTRESS satellite mission was acquired to assess the potential of spaceborne thermal monitoring. Based on our preliminary assessment, VTP, TIR, and bed temperature measurements provide complementary spatial coverage, temporal sampling, and resolution; these methods have potential for long-term, automated monitoring of HEFs. The publicly available spaceborne imagery, however, proved inadequate because of insufficient spatial resolution and data gaps resulting from cloud cover and revisit frequency.

54 ENVIRONMENTAL SCIENCES↗

Combustion Performance and Emissions Optimization Through Integration of a Miniaturized High-Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Combustion Performance and Emissions Optimization through Integration of Miniaturized High Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. The new sensor design, leveraging the existing electrochemical noise-based monitoring system, is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data can be transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Combustion Performance and Emissions Optimization Through Integration of a Miniaturized High-Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. The new sensor design, leveraging the existing electrochemical noise-based monitoring system, is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data can be transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Combustion Performance and Emissions Optimization Through Integration of a Miniaturized High-Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution of wall conditions in utility boilers. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of a coal-fired utility boiler in this project but can be applied to many other industries and applications as well. The new sensor design, leveraging the existing electrochemical noise-based monitoring system, is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data can be transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

42 ENGINEERING↗

High-Temperature Multi-Process Sensor Development and Demonstration at a Full-scale PC Combustion System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution of wall conditions in utility boilers. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of a coal-fired utility boiler in this project but can be applied to many other industries and applications as well. The new sensor design, leveraging the existing electrochemical noise-based monitoring system, is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data can be transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Joint optimal scheduling for electric vehicle battery swapping-charging system based on wind farms

Insufficiencies in charging facilities limit the broad application of electric vehicles (EVs). In addition, EV can hardly represent a green option if its electricity primarily depends on fossil energy. Considering these two problems, this paper studies a battery swapping-charging system based on wind farms (hereinafter referred to as W-BSCS). In a W-BSCS, the wind farms not only supply electricity to the power grid but also cooperate with a centralized charge station (CCS), which can centrally charge EV batteries and then distribute them to multiple battery swapping stations (BSSs). The operational framework of the W-BSCS is analyzed, and some preprocessing technologies are developed to reduce complexity in modeling. Then, a joint optimal scheduling model involving a wind power generation plan, battery swapping demand, battery charging and discharging, and a vehicle routing problem (VRP) is established. Then a heuristic method based on the exhaustive search and the Genetic Algorithm is employed to solve the formulated NP-hard problem. Numerical results verify the effectiveness of the joint optimal scheduling model, and they also show that the W-BSCS has great potential to promote EVs and wind power.

17 WIND ENERGY↗

A general spatial-temporal framework for short-term building temperature forecasting at arbitrary locations with crowdsourcing weather data

Weather forecasting has been a critical component to predict and control building energy consumption for better building energy management. Without accessibility to other data sources, the onsite observed temperatures or the airport temperatures are used in forecast models. In this paper, we present a novel approach by utilizing the crowdsourcing weather data from neighboring personal weather stations (PWS) to improve the weather forecast accuracy around buildings using a general spatial-temporal modeling framework. The final forecast is based on the ensemble of local forecasts for the target location using neighboring PWSs. Our approach is distinguished from existing literature in various aspects. First, we leverage the crowdsourcing weather data from PWS in addition to public data sources. In this way, the data is at much finer time resolution (e.g., at 5-minute frequency) and spatial resolution (e.g., arbitrary location vs grid). Second, our proposed model incorporates spatial-temporal correlation information of weather variables between the target building and a set of neighboring PWSs so that underlying correlations can be effectively captured to improve forecasting performance. Here, we demonstrate the performance of the proposed framework by comparing to the benchmark models on temperature forecasting for a building located at an arbitrary location at San Antonio, Texas, USA. In general, the proposed model framework equipped with machine learning technique such as Random Forest can improve forecasting by 50% compares with persistent model and has 90% chance to outperform airport forecast in short-term forecasting. In a real-time setting, the proposed model framework can provide more accurate temperature forecasting results compared with using airport temperature forecast for most forecast horizon. Moreover, we analyze the sensitivity of model parameters to gain insights on how crowdsourcing data from the neighboring personal weather stations impacts forecasting performance. Finally, we implement our model in other cities such as Syracuse and Chicago to test the model's performance in different landforms and climate types.

54 ENVIRONMENTAL SCIENCES↗

System risk quantification and decision making support using functional modeling and dynamic Bayesian network

Risk-informed decision-making requires a probabilistic assessment of the likelihood of success of control action, given the system status. This paper presents a systematic state transition modeling approach integrating dynamic probabilistic risk assessment with a decision-making process using a dynamic Bayesian network (DBN) coupled with functional modeling. A functional model designed with multilevel flow modeling (MFM) technique was used to build a system state structure inferred by energy, mass, and information flow so that one can verify the developed model with respect to system functionality. The MFM model represents the causal relationship among the nodes, which captures the structure of process parameters and control units. Each node may have multiple possible states, and the DBN structured by the MFM model represents the time-domain transitions among the defined states. Furthermore, the MFM-DBN integrated state transition modeling is a white-box approach that allows one to draw the system's risk profile by updating the system states and supports the decisions probabilistically with physical inference. An example of a simple heating system has been used to illustrate this process, including decision-making support based on quantitative risk profile. For demonstrating its applicability to a complex system operational decision making, a case study of station blackout accident scenario leading to the seal loss of coolant accident in a nuclear power plant is presented. The proposed approach effectively provided the risk profile along time for each option so that the operators can make the best decision, which minimizes the plant risk.

42 ENGINEERING↗

Adaptive Fault Current-Limiting Control of MMC for Protection of Multiterminal HVDC Systems

A crucial requirement of the protection system for multi-terminal high-voltage DC (MTDC) transmission is that it is capable of selectively isolating the faulty area from the healthy part of the network using DC circuit breakers (DCCBs), while ensuring continuous operation of converter stations in the healthy part of the network. But in the half-bridge modular multilevel converters (HB-MMCs) based MTDC system, since HB-MMCs do not have fault current absorption capability, when a DC fault occurs, the rising fault currents can quickly reach the blocking threshold within a few milliseconds and disrupt the operation of the MMCs in the healthy part. To facilitate fault-ride-through capability of MTDC system, large DC reactors are often considered in series with DCCBs to reduce the rate of rise of the fault current and prevent blocking the MMCs in the healthy part of the DC networks; however, large DC reactors prohibitively increase the cost of the system, introduce stability issues and can create post-fault oscillations. This paper presents an adaptive fault current-limiting control method for MMCs to avoid their blocking and enable the continuous operation of the healthy part of MTDC systems. The method contains two parts: The first part is based on circulating current feedforward control, which emulates virtual reactors in each arm of an MMC, and is immediately activated when the fault current starts to increase to reduce the rate of rise of the fault current. The second part temporarily bypasses all the submodules when the fault current exceeds a preset threshold, complementing the fault current-limiting effect of the first part. Neither part requires fault detection signals, and they are automatically activated during faults. Simulation case studies of a four-terminal bipolar MMC-based high-voltage DC system are presented to demonstrate the effectiveness of the proposed control methods.

active fault current limiting↗

Characterization of coal extracts and their performances as binder for new carbon-based structural units

Coal production and usage have been declining in the past decade due to the transition to renewable energies, environmental regulations to reduce environmental pollution due to direct coal combustion from coal-fired power stations, and administrative policies. This downturn has created tremendous challenges for the coal industry, and many states rely on revenue from coal mining. Developing new valorization routes with high coal demand is essential and using coal-derived materials to make engineered products does offer an eco-friendly, attractive, and value-added use. This paper presents a brief introduction to the extraction process to derive coal deposits, extracts, and residuals (CDERs) and a comprehensive characterization analysis to determine the suitability of CDERs as binders to produce an innovative construction material named the carbon-based structural unit (CSU). CDERs are used to prepare the CSU with or without using mesophase pitch (MP) as binders and selected CDERs are heat-treated and pressure-heat-treated to improve their binding capabilities. The performances of the CSU specimens are evaluated based on compressive strength, density, and thermal conductivity. The CSU specimens mixed with distilled residue (DR) to pyrolysis char (PC) ratio of 1:2 achieve a compressive strength of 54.85 MPa, which is higher than the compressive strength of 30 MPa of normal concrete. The CSU specimens with deposit (De) and tetralin insoluble (TI) require the addition of MP to obtain compressive strengths greater than 30 MPa. Furthermore, these CSU specimens possess a relatively low density of about 1 g/cm 3 and low thermal conductivity of less than 0.25 W/m.K.

36 MATERIALS SCIENCE↗

Forming more and sharper sensing protrusions on graphene-based electrodes through annealing

A better understanding of the microstructure, physicochemical properties, and sensing behavior of an electrode is critical in developing quick, high sensitivity, and robust electrochemical sensors. Here, in this study, a single electrode was fabricated with self-prepared graphene ink through a drop-cast process followed with a subsequent annealing treatment. The graphene ink-based electrodes were characterized through AFM, contact angle, FTIR, impedance spectra, Raman, and SEM to understand annealing treatment effects. The dynamic response of the electrode to humidity, and vapors of ethanol, propanol, or acetone was measured using a four-point probe station in a closed chamber. The annealing treatment increased the conductivity of the electrode and improved its sensing performance by forming more and sharper protrusions on the electrode surface. These unique surface protrusions suggest that the annealed graphene ink-based electrodes hold great potential in developing high-performance electrochemical sensors.

42 ENGINEERING↗

JTAG-based PLC memory acquisition framework for industrial control systems

In industrial control systems (ICS), programmable logic controllers (PLC) are the embedded devices that directly control and monitor critical industrial infrastructure processes such as nuclear plants and power grid stations. Cyberattacks often target PLCs to sabotage a physical process. A memory forensic analysis of a suspect PLC can answer questions about an attack, including compromised firmware and manipulation of PLC control logic code and I/O devices. Given physical access to a PLC, collecting forensic information from the PLC memory at the hardware-level is risky and challenging. It may cause the PLC to crash or hang since PLCs have proprietary, legacy hardware with heterogeneous architecture. This paper addresses this research problem and proposes a novel JTAG (Joint Test Action Group)-based framework, Kyros, for reliable PLC memory acquisition. Kyros systematically creates a JTAG profile of a PLC through hardware assessment, JTAG pins identification, memory map creation, and optimizing acquisition parameters. It also facilitates the community of interest (such as ICS owners, operators, and vendors) to develop the JTAG profiles of PLCs. Further, we present a case study of Kyros implementation over Allen-Bradley 1756-A10/B to help understand the framework's application on a real-world PLC used in industry settings. The sample PLC memory dumps are shared with the research community to facilitate further research.

Rais, Muhammad Haris↗

Prediction of Potential and Actual Evapotranspiration Fluxes Using Six Meteorological Data-Based Approaches for a Range of Climate and Land Cover Types

Evapotranspiration is the major component of the water cycle, so a correct estimate of this variable is fundamental. The purpose of the present research is to assess the monthly scale accuracy of six meteorological data-based models in the prediction of evapotranspiration (ET) losses by comparing the modelled fluxes with the observed ones from eight sites equipped with eddy covariance stations which differ in terms of vegetation and climate type. Three potential ET methods (Penman-Monteith, Priestley-Taylor, and Blaney-Criddle models) and three actual ET models (the Advection-Aridity, the Granger and Gray, and the Antecedent Precipitation Index method) have been proposed. The findings show that the models performances differ from site to site and they depend on the vegetation and climate characteristics. Indeed, they show a wide range of error values ranging from 0.18 to 2.78. It has been not possible to identify a single model able to outperform the others in each biome, but in general, the Advection-Aridity approach seems to be the most accurate, especially when the model calibration in not carried out. It returns very low error values close to 0.38. When the calibration procedure is performed, the most accurate model is the Granger and Gray approach with minimum error of 0.13 but, at the same time, it is the most impacted by this process, and therefore, in a context of data scarcity, it results the less recommended for ET prediction. The performances of the investigated ET approaches have been furthermore tested in case of lack of measured data of soil heat fluxes and net radiation considering using empirical relationships based on meteorological data to derive these variables. Results show that, the use of empirical formulas to derive ET estimates increases the errors up to 200% with the consequent loss of model accuracy.

net radiation↗

Commercial-scale Carbon Storage Complex Feasibility Study at Dry Fork Station, Wyoming

This report summarizes the results of the technical and nontechnical feasibility study (“Phase II”) conducted as part of the “Commercial-Scale Carbon Storage Complex Feasibility Study at Dry Fork Station, Wyoming” project (“Wyoming CarbonSAFE”), which is part of the U.S. Department of Energy’s (“DOE”) National Energy Technology Laboratory’s (“NETL”) Carbon Storage Assurance Facility Enterprise (“CarbonSAFE”) Initiative. This report concludes that the Wyoming CarbonSAFE project is feasible based upon analyses of numerous technical and non-technical criteria in Phase II.

54 ENVIRONMENTAL SCIENCES↗

Signal Whisperers: Enhancing Wireless Reception Using DRL-Guided Reflector Arrays

This paper presents a multi-agent reinforcement learning (MARL) approach for controlling adjustable metallic reflector arrays to enhance wireless signal reception in non-line-of-sight (NLOS) scenarios. Unlike conventional reconfigurable intelligent surfaces (RIS) that require complex channel estimation, our system employs a centralized training with decentralized execution (CTDE) paradigm where individual agents corresponding to reflector segments autonomously optimize reflector element orientation in three-dimensional space using spatial intelligence based on user location information. Through extensive ray-tracing simulations with dynamic user mobility, the proposed multi-agent beam-focusing framework demonstrates substantial performance improvements over single-agent reinforcement learning baselines, while maintaining rapid adaptation to user movement within one simulation step. Comprehensive evaluation across varying user densities and reflector configurations validates system scalability and robustness. The results demonstrate the potential of learning-based approaches for adaptive wireless propagation control.

deep reinforcement learning↗

Design of Advanced 1MHz, 1mw Three Phase AC to DC Ultra Fast EV Charger (Final Scientific/Technical Report)

This project embarked to create a compact high-density 1MW EV charger. This project reduced the time to charge an EV with ~400 miles of range to two minutes. This EV charger can be leveraged for residential day-to-day customers and also leveraged for commercial large vehicles such as semi-trucks, delivery trucks, and heavy duty off road. EV chargers of this power capability will reduce consumers range anxiety (The worry of running out of charger in an EV before the customer can get to a charger station.) This will help increase the number of EV’s on the road resulting in decreased use of ICE fossil-based fuel vehicles, reduced emission, and reduced dependence on fossil fuels.

42 ENGINEERING↗