Modeling of high intensity orbital angular momentum beams for laser–plasma interactions

In this work, we explore the field of high intensity orbital angular momentum (OAM) beams, their generation with spiral phase mirrors, and the theory behind modeling both ideal and realistic beams. We explore OAM beam asymmetries introduced by aberrations in the beam, manufacturing defects, and bandwidth. A full three-dimensional description of the paraxial Laguerre–Gaussian (LG) modes suitable for modeling beams down to f/2 focal geometries is derived. A perturbative approach to modeling asymmetric OAM beams is introduced showing that only three LG modes are sufficient to model a wide variety of OAM asymmetries. The models are compared with experimental results followed by a discussion on the future of high intensity OAM beams in plasma physics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement and reduction of Ar metastable densities by nitrogen admixing in electron beam-generated plasmas

Abstract Electron beam (e-beam) generated plasmas are useful for material processing applications such as deposition and etching because the plasmas deliver a large fluence of very low energy of ions to surfaces. Metastable species produced in the beam-region can also transport significant energy to the plasma periphery and surfaces. In this work, we have investigated the spatially resolved density of metastable Ar 1s 5 species produced in an Ar and Ar/N 2 e-beam generated plasma at pressures of 60–67 mTorr using laser-induced fluorescence (LIF). The experiments provide the first direct measure of absolute density and reduction of Ar 1s 5 in an e-beam generated plasma when argon is diluted with nitrogen. These results are consistent with previous predictions of numerical modeling and measurements using optical emission spectroscopy. The present spatially resolved LIF measurements directly quantify the reduction of Ar 1s 5 in the e-beam generated plasma by nitrogen admixing. This reduction was observed in the region of the electron beam and in the plasma periphery, where substrates are usually placed. For example, up to a threefold reduction of the density of Ar 1s 5 was measured when the argon background was diluted with 15.5% nitrogen at pressure of 60 mTorr. Ar 1s 5 reduction is attributed to excitation exchange with nitrogen molecules as well as the cooling of plasma electrons via inelastic collisions with nitrogen molecules.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Landau Damping with Electron Lenses in Space-Charge Dominated Beams

Further progress of fundamental physics requires accelerated beams of high intensity. The intensities, however, are limited by many factors, including coherent beam instabilities. Usual methods to control the instabilities, such as octupole magnets, beam feedback dampers and employment of chromatic effects, may be ineffective or insufficient. In this study, electron lenses were proposed as a means to provide stabilizing spread in the beam betatron frequencies. It was shown that electron lenses are uniquely effective for Landau damping of transverse beam instabilities in high energy particle accelerators, and that their employment does not compromise incoherent (single particle) stability, dynamic aperture and the beam lifetime. Here we consider effectiveness of the Landau damping with electron lenses when the space charge tune shift cannot be neglected. We demonstrate that the desired stability can be assured with proper choice of the electron beam parameters and current distributions.

43 PARTICLE ACCELERATORS↗

Modeling and design of compact, permanent-magnet transport systems for highly divergent, broad energy spread laser-driven proton beams

Laser-driven (LD) ion acceleration has been explored in a newly constructed short focal length laser beamline at the BELLA petawatt facility (interaction point 2, iP2). For applications utilizing such LD ion beams, a beam transport system is required, which for reasons of compactness be ideally contained within 3 m. While they are generated from a micron-scale source, large divergence and energy spread of LD ion beams present a unique challenge to transporting them compared to beams from conventional accelerators. This study gives an overview of proposed compact transport designs using permanent magnets satisfying different requirements depending on the application for the iP2 laser beamline such as radiation biology, material science, and high-energy density science. These designs are optimized for different parameters such as energy spread and peak proton density according to the application’s need. The various designs consist solely of permanent magnet elements, which can provide high magnetic field gradients on a small footprint. While the field strengths are fixed, we have shown that the beam size is able to be tuned effectively by varying the placement of the magnets. The performance of each design was evaluated based on high-order particle tracking simulations of typical LD proton beams. We also examine the ability of certain configurations to tune and select beam energies, critical for specific applications. A more detailed investigation was carried out for a design to deliver 10 MeV LD accelerated ions for radiation biology applications. With these transport system designs, the iP2 laser beamline is ready to house various application experiments.

43 PARTICLE ACCELERATORS↗

Experimental Demonstration of Hadron Beam Cooling Using Radio-Frequency Accelerated Electron Bunches

Cooling of beams of gold ions using electron bunches accelerated with radio-frequency systems was recently experimentally demonstrated in the Relativistic Heavy Ion Collider at Brookhaven National Laboratory. Such an approach is new and opens the possibility of using this technique at higher energies than possible with electrostatic acceleration of electron beams. The challenges of this approach include generation of electron beams suitable for cooling, delivery of electron bunches of the required quality to the cooling sections without degradation of beam angular divergence and energy spread, achieving the required small angles between electron and ion trajectories in the cooling sections, precise velocity matching between the two beams, high-current operation of the electron accelerator, as well as several physics effects related to bunched-beam cooling. Here we report on the first demonstration of cooling hadron beams using this new approach.

43 PARTICLE ACCELERATORS↗

Optimize Electron Beam Energy toward In Situ Imaging of Thick Frozen Bio-Samples with Nanometer Resolution Using MeV-STEM

To optimize electron energy for in situ imaging of large biological samples up to 10 μm in thickness with nanoscale resolutions, we implemented an analytical model based on elastic and inelastic characteristic angles. This model has been benchmarked by Monte Carlo simulations and can be used to predict the transverse beam size broadening as a function of electron energy while the probe beam traverses through the sample. As a result, the optimal choice of the electron beam energy can be realized. In addition, the impact of the dose-limited resolution was analysed. While the sample thickness is less than 10 μm, there exists an optimal electron beam energy below 10 MeV regarding a specific sample thickness. However, for samples thicker than 10 μm, the optimal beam energy is 10 MeV or higher depending on the sample thickness, and the ultimate resolution could become worse with the increase in the sample thickness. Moreover, a MeV-STEM column based on a two-stage lens system can be applied to reduce the beam size from one micron at aperture to one nanometre at the sample with the energy tuning range from 3 to 10 MeV. In conjunction with the state-of-the-art ultralow emittance electron source that we recently implemented, the maximum size of an electron beam when it traverses through an up to 10 μm thick bio-sample can be kept less than 10 nm . This is a critical step toward the in situ imaging of large, thick biological samples with nanometer resolution.

36 MATERIALS SCIENCE↗

In-flight production of an isomeric beam of 16 N

In this work, an in-flight beam of 16 N was produced via the single-neutron adding ($\textit{d,p}$) reaction in inverse kinematics at the recently upgraded Argonne Tandem Linear Accelerator System (ATLAS) in-flight system. The amount of the 16 N beam which resided in its excited 0.120 MeV $J^\pi$ = 0 – isomeric state (T 1/2 ≈ 5 μs) was determined to be 40(5)% at a reaction energy of 7.9(3) MeV/$\textit{u}$, and 24(2)% at a reaction energy of 13.2(2) MeV/$\textit{u}$. The isomer measurements took place at an experimental station ≈ 30 m downstream of the production target and utilized an Al beam-stopping foil and a HPGe Clover detector. Composite 16 N beam rate determinations were made at the experimental station and the focal plane of the Argonne in-flight radioactive ion-beam separator (RAISOR) with Si ΔE-E telescopes. A Distorted Wave Born Approximation (DWBA) approach was coupled with the known spectroscopic information on 16 N in order to estimate the relative 16 N isomer yields and composite 16 N beam rates. In addition to the observed reaction-energy dependence of the isomer fraction, a large sensitivity to the angular acceptance of the recoils was also observed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Electron beam irradiation effects on bulk metals: a comparative study of polycrystalline versus single-crystalline structures

This study investigates the effects of electron beam (e-beam) irradiation on the mechanical and structural properties of eight bulk metallic samples, comprising both polycrystalline (PC) and single-crystalline (SC) forms of Ni, Cr, V, and Ti. These metals were evaluated as potential candidates for beam exit windows in high-power (MW-class) particle accelerators. The primary objective is to identify metals capable of withstanding the conditions of high-power/MW-class e-beam accelerators and serve effectively as exit windows. Selection criteria were based on each metal’s intrinsic properties, power dissipation capability, and irradiation-induced changes in mechanical behavior, including hardness, elastic modulus, and defect density. Comprehensive characterization was conducted using field-emission scanning electron microscopy (FESEM), atomic force microscopy (AFM), scanning electron microscopy with energy-dispersive X-ray spectroscopy (SEM–EDS), X-ray diffraction (XRD), high-resolution transmission electron microscopy (HRTEM), selected area electron diffraction (SAED), and nanoindentation, performed both before and after exposure to a ~¿66 kGy dose from a 10 MeV e-beam accelerator. Results revealed that e-beam irradiation induced hardening in PC Ni, whereas PC Ti, commonly used in beam exit windows, exhibited softening. The observed softening in PC Ti is attributed to grain coarsening, elongation, and the formation of twins and twin boundaries, in contrast to the smaller, compressed grains in the pristine (Pr) PC Ti samples, consistent with the Hall–Petch relationship. The stresses due to twinning are small and insignificant in influencing the overall hardening of the PC Ti irradiated sample when compared to the stresses due to the dislocation density. Conversely, SC Ti samples exhibited irradiation-induced hardening. The SC Ti irradiated samples developed additional irradiation-induced modifications in crystallographic texture of (100), (101), (110), (200), (112), (004), and (211) as evidenced from the XRD results, which could probably explain the hardening effect that is caused by irradiation.

36 MATERIALS SCIENCE↗

Micro-cantilever beam experiments and modeling in porous polycrystalline UO 2

Understanding the impact of microstructure on the thermo-mechanical behavior of oxide nuclear fuels is vital to predicting their performance through multiscale models. Evaluating the mechanical properties at the sub-grain length scale is key to developing these multiscale models. In this work, 3D finite element (FE) models were constructed to simulate the micrometer-scale bending of micro-cantilever beams fabricated using porous polycrystalline uranium dioxide (UO 2 ) and tested at room temperature. Here, the results showed that the porosity and elastic anisotropy of individual grains can play a significant role in determining the effective mechanical properties of the material deduced from the tests. Specifically, the porosity had a non-negligible effect, given that the pore size was of the same order of magnitude as the dimensions of the micro-beams. Correlations between load-deflection data, pore location, and elastic properties (effective Young's modulus) were investigated using UO 2 micro-beam FE models, where pore clusters were included and placed at different locations along the length of the beam. Results indicated that the presence of pore clusters near the substrate, i.e., the clamp of the micro-cantilever beam, has the strongest effect on the load-deflection behavior, with the porosity leading to a reduction of stiffness that is the largest for any location of the pore clusters. Furthermore, it was also found that pore clusters located towards the middle of the span and close to the end of the beam have a comparatively small effect on the load-deflection behavior. Therefore, it is concluded that accurate estimates of Young's modulus can be obtained from micro-cantilever experiments after accounting for porosity on the one third of the beam length close to the clamp. This, in turn, provides an avenue to improve microscale experiments and their analysis in porous, anisotropic elastic materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of a versatile plate spectrometer for electron beam characterization

A new instrument for electron beam characterization has been developed, based on measuring the range of beam electrons in different thicknesses of aluminum, to determine both the current and energy of an electron beam traveling in open air. This instrument is referred to as a ‘plate spectrometer’ as the thickness of the spectrometer is adjusted by adding or removing aluminum plates. This spectrometer was assembled and then characterized at the Idaho Accelerator Center (IAC) with three different beam energies and with one beam energy at the University of Maryland Radiation Facilities. The plate spectrometer was able to match the median energies and provide a reasonable constraint to the beam distributions seen in the IAC magnetic spectrometer. Finally, in a separate experiment, the plate spectrometer was also seen to agree with a dosimetry characterization of the beam at the University of Maryland Radiation Facilities and improved upon the uncertainties of this measurement.

43 PARTICLE ACCELERATORS↗

Quantitative Specifications to Avoid Degradation during E-Beam and Induced Current Microscopy of Halide Perovskite Devices

Degradation due to electron beam exposure has posed a challenge in the use of electron microscopy to probe halide perovskite materials and devices. Herein, the interaction between the electron beam and the perovskite across acceleration voltages and at low probe currents is investigated in a scanning electron microscope (SEM) by monitoring the electron-beaminduced current (EBIC) response in perovskite solar cells in a planview configuration. SEM probe conditions are identified where dozens of repeated scans over a single region of the perovskite solar cell induce minimal electronic degradation. Overall, the induced current response of the perovskite device is found to strongly depend upon the beam condition: rapid decay occurs at high beam powers, the current activates at the lowest beam powers, and a newfound quasi-steady response is revealed at intermediate beam conditions. A quantitative window for the successful conduction of e-beam studies with minimal electronic degradation is revealed by evaluating induced current response over a wide range of perovskite devices, which invites broader use of SEM-based characterization techniques, including EBIC, as powerful techniques for correlative microscopy investigations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Whistler Waves Associated With Electron Beams in Magnetopause Reconnection Diffusion Regions

Abstract Whistler waves are often observed in magnetopause reconnection associated with electron beams. We analyze seven MMS crossings surrounding the electron diffusion region (EDR) to study the role of electron beams in whistler excitation. Waves have two major types: (a) Narrow‐band waves with high ellipticities and (b) broad‐band waves that are more electrostatic with significant variations in ellipticities and wave normal angles. While both types of waves are associated with electron beams, the key difference is the anisotropy of the background population, with perpendicular and parallel anisotropies, respectively. The linear instability analysis suggests that the first type of wave is mainly due to the background anisotropy, with the beam contributing additional cyclotron resonance to enhance the wave growth. The second type of broadband waves are excited via Landau resonance, and as seen in one event, the beam anisotropy induces an additional cyclotron mode. The results are supported by particle‐in‐cell simulations. We infer that the first type occurs downstream of the central EDR, where background electrons experience Betatron acceleration to form the perpendicular anisotropy; the second type occurs in the central EDR of guide field reconnection. A parametric study is conducted with linear instability analysis. A beam anisotropy alone of above ∼3 likely excites the cyclotron mode waves. Large beam drifts cause Doppler shifts and may lead to left‐hand polarizations in the ion frame. Future studies are needed to determine whether the observation covers a broader parameter regime and to understand the competition between whistler and other instabilities.

79 ASTRONOMY AND ASTROPHYSICS↗

Attosecond-Angstrom free-electron-laser towards the cold beam limit

Electron beam quality is paramount for X-ray pulse production in free-electron-lasers (FELs). State-of-the-art linear accelerators (linacs) can deliver multi-GeV electron beams with sufficient quality for hard X-ray-FELs, albeit requiring km-scale setups, whereas plasma-based accelerators can produce multi-GeV electron beams on metre-scale distances, and begin to reach beam qualities sufficient for EUV FELs. Here we show, that electron beams from plasma photocathodes many orders of magnitude brighter than state-of-the-art can be generated in plasma wakefield accelerators (PWFAs), and then extracted, captured, transported and injected into undulators without significant quality loss. These ultrabright, sub-femtosecond electron beams can drive hard X-FELs near the cold beam limit to generate coherent X-ray pulses of attosecond-Angstrom class, reaching saturation after only 10 metres of undulator. This plasma-X-FEL opens pathways for advanced photon science capabilities, such as unperturbed observation of electronic motion inside atoms at their natural time and length scale, and towards higher photon energies.

43 PARTICLE ACCELERATORS↗

Poincaré beams from a free electron laser

Poincaré beams are light beams that have spatially inhomogeneous polarization structure that spans a finite portion of the Poincaré sphere. This feature bestows the beams with intriguing topological properties and has led to a surge in research on their fundamental characteristics, their controlled generation and on emerging applications. Here we present an experimental demonstration of a Poincaré beam generated in the extreme ultraviolet (16.7 nm) at the FERMI free electron laser (FEL). The ‘star’ type Poincaré beam is generated by exploiting the phase and intensity structure intrinsic to FEL radiation without relying on optical elements. Here, we controlled the spatial polarization distribution through a precise overlap and power balance between two FEL pulses, each with different transverse phase distributions and orthogonal circular polarizations. The spatial polarization structure was mapped in detail and shows extensive coverage of the Poincaré sphere, in agreement with analytic predictions. This method of in situ Poincaré beam production in FELs enables straightforward flexibility in the orientation and balance of polarization states, and can readily be extended to other vector beams and to shorter wavelengths enabling novel science applications in modern light sources.

Morgan, Jenny [SLAC National Accelerator Laborator↗

Mutually guided light and particle beam propagation

The polarizability of atoms and molecules gives rise to optical forces that trap particles and a refractive index that guides light beams, potentially leading to a self-guided laser and particle beam propagation. In this paper, the mutual interactions between an expanding particle beam and a diffracting light beam are investigated using an axisymmetric particle-light coupled simulation. The nonlinear coupling between particles and photons is dependent on the particle beam radius, particle density, particle velocity and temperature, polarizability, light beam waist, light frequency (with respect to the resonance frequency), and light intensity. The computational results show that the maximum propagation distance is achieved when the waveguiding effect is optimized to single-mode operation. The application of the coupled beam propagation as a space propulsion system is discussed.

42 ENGINEERING↗

Conditional guided generative diffusion for particle accelerator beam diagnostics

Abstract Advanced accelerator-based light sources such as free electron lasers (FEL) accelerate highly relativistic electron beams to generate incredibly short (10s of femtoseconds) coherent flashes of light for dynamic imaging, whose brightness exceeds that of traditional synchrotron-based light sources by orders of magnitude. FEL operation requires precise control of the shape and energy of the extremely short electron bunches whose characteristics directly translate into the properties of the produced light. Control of short intense beams is difficult due to beam characteristics drifting with time and complex collective effects such as space charge and coherent synchrotron radiation. Detailed diagnostics of beam properties are therefore essential for precise beam control. Such measurements typically rely on a destructive approach based on a combination of a transverse deflecting resonant cavity followed by a dipole magnet in order to measure a beam’s 2D time vs energy longitudinal phase-space distribution. In this paper, we develop a non-invasive virtual diagnostic of an electron beam’s longitudinal phase space at megapixel resolution (1024 × 1024) based on a generative conditional diffusion model. We demonstrate the model’s generative ability on experimental data from the European X-ray FEL.

43 PARTICLE ACCELERATORS↗

Measurements of a 2.1 MeV H− beam with an Allison scanner

Transverse 2D phase space distributions of a 2.1 MeV, 5 mA H− beam are measured at the Proton Improvement Plan II Injector Test accelerator at Fermilab with an Allison scanner. This paper describes the design, calibration, and performance of the scanner along with the main results from beam measurements. Analyses of the recorded phase portraits are performed primarily in action-phase coordinates. The stability of the action under linear optics makes it easier to compare measurements taken under different beamline conditions. The amplitude of a single measured point (“pixel”) is proportional to the phase density in the corresponding portion of the beam. When the Twiss parameters are calculated using only the high-phase density part of the beam, the pixel amplitude in the beam core is found to be decreasing approximately exponentially with action and to be phase-independent. Outside of the core, the amplitudes decrease with action at a slower rate than in the core. This “tail” comprises 10%–30% of the beam, with 0.1% of the total measured intensity extending beyond action 10–20 times larger than the rms emittance. The transition from the core to the tail is accompanied by the appearance of two “branches” that are separated in phase and extend beyond the core. A set of selected measurements shows that there is no measurable emittance dilution along the beamline; the beam parameters are practically constant over a 0.5 ms pulse; and scraping in various parts of the beamline is an effective way to decrease the transverse tails by removing the branches.

Richard, C. (ORCID:000000029891135X)↗

Using solenoid as multipurpose tool for measuring beam parameters

Solenoids are frequently used for focusing low-energy beams. In this paper, we show how they can serve as multipurpose diagnostics tools to measure various beam parameters, including energy, emittance, the second moments of the transverse distribution, and the beam position and angle with respect to the solenoid’s axis. The energy measurement is based on rotation of the plane of the transverse motion, as opposed to generating dispersion with a dipole. Measurement of the beam trajectory with respect to the solenoid axis is done by analyzing the beam orbit downstream of the solenoid while varying its current. The second moments are calculated by analyzing the beam image on a profile monitor while accounting for the beam rotation caused by the solenoid. We describe in detail the corresponding procedures and the experimental results of these measurements.