Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM SHAPING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Enhanced Laser Damage Threshold in Optically Addressable Light Valves via Aluminum Nitride Photoconductors

Abstract Optically addressable light valves (OALVs) are specialized optical components utilized for spatial beam shaping in various laser‐based applications, including optics damage mitigation, and enhanced functionality in diode‐based additive manufacturing requiring high intensities. Current state‐of‐the‐art OALVs employ photoconductors such as Bismuth Silicon Oxide (BSO) or Bismuth Germanium Oxide (BGO), which suffer from limited laser‐induced damage thresholds (LiDT) and inadequate thermal conductivities, thus restricting their use in high peak and average power applications. Aluminum nitride (AlN), an emerging ultra‐wide band gap (UWBG) III–V semiconductor, offers promising optoelectronic properties and superior thermal conductivity (>300 Wm −1 K −1 at 298° K, compared to BSO's 3.29 Wm −1 K −1 ). In this study, the first AlN‐based OALVs are designed, fabricated, and experimentally demonstrated using commercially available single‐crystal AlN substrates. These AlN‐based OALVs have shown clear superiority over BSO and BGO‐based devices. Design considerations for OALVs incorporating UWBG photoconductors are discussed, and the photoresponsivity from defect‐mediated sub‐bandgap absorption in AlN crystals is verified as sufficient for OALVs operating under high light fluences. The optimum driving voltage for the AlN‐based OALV is determined to be ≈ 45 V pp at 100 Hz, achieving a transmittance of 91.3%, an extinction ratio (ER) of more than 100, and a 51:1 image contrast.

36 MATERIALS SCIENCE↗

Subcellular-level resolution MALDI-MS imaging of maize leaf metabolites by MALDI-linear ion trap-Orbitrap mass spectrometer

A significant limiting factor in achieving high spatial resolution for matrix-assisted laser desorption ionization-mass spectrometry (MALDI-MS) imaging is the size of the laser spot at the sample surface. We present modifications to the beam-delivery optics of a commercial MALDI-linear ion trap-Orbitrap instrument, incorporating an external Nd:YAG laser, beam-shaping optics, and an aspheric focusing lens, to reduce the minimum laser spot size from ~50 μm for the commercial configuration down to ~9 μm for the modified configuration. This improved system was applied for MALDI-MS imaging of cross sections of juvenile maize leaves at 5-μm spatial resolution using an oversampling method. There are a variety of different metabolites including amino acids, glycerolipids, and defense-related compounds were imaged at a spatial resolution well below the size of a single cell. Such images provide unprecedented insights into the metabolism associated with the different tissue types of the maize leaf, which is known to asymmetrically distribute the reactions of C4 photosynthesis among the mesophyll and bundle sheath cell types. The metabolite ion images correlate with the optical images that reveal the structures of the different tissues, and previously known and newly revealed asymmetric metabolic features are observed.

47 OTHER INSTRUMENTATION↗

Extrapulmonary Soft-Tissue Fibrosis Resulting From Hypofractionated Stereotactic Body Radiotherapy for Pulmonary Nodular Lesions

Purpose: To clarify the incidence, symptoms, and timing of extrapulmonary fibrosis developing after hypofractionated stereotactic body radiotherapy. Patients and Methods: We analyzed 379 consecutive patients who underwent stereotactic body radiotherapy for lung tumors at four institutions between February 2001 and March 2007. The median follow-up time was 29 months (range, 1-72). We investigated the subjective and objective characteristics of the extrapulmonary masses, redelineated the origin tissue of each on the treatment planning computed tomography scan, and generated dose-volume histograms. Results: In 9 patients (2.4%), extrapulmonary masses were found 3-36 months (median, 14) after irradiation. Coexisting swelling occurred in 3 patients, chest pain in 2, thumb numbness in 1, and arm edema in 1 patient. Extrapulmonary masses occurred in 5 (5.4%) of 92 and 4 (1.4%) of 287 patients irradiated with a 62.5-Gy and 48.0-Gy isocenter dose, respectively. The mean and maximal dose to the origin tissue was 25.8-53.9 Gy (median, 43.7) and 47.5-62.5 Gy (median, 50.2), respectively. In 5 of 9 patients, the standardized uptake values on 18F-fluorodeoxyglucose-positron emission tomography was 1.8-2.8 (median, 2.2). Percutaneous needle biopsy was performed in 3 patients, and all the specimens showed benign fibrotic changes without malignant cells. Conclusion: All patients should be carefully followed after stereotactic body radiotherapy. The findings of any new lesion should prompt an assessment for radiation-induced extrapulmonary fibrosis before an immediate diagnosis of recurrence is made. Careful beam-shape modification and dose prescription near the thoracic outlet are required to prevent forearm neuropathy and lymphedema.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Pelvic Phantom for Modeling Internal Organ Motions

A pelvic phantom was developed for use in testing image-guided radiation therapy (IGRT) and adaptive applications in radiation therapy (ART) with simulating the anterior-posterior internal organ motions during prostate radiotherapy. Measurements could be done with an ionization chamber (IC) in the simulated prostate. The rectum was simulated by air-equivalent material (AEM). The volume superior to the IC placement was considered as the bladder. The extension of AEM volume could be varied. The vertical position of the IC placement could be shifted by {+-}1 cm to simulate the prostate motion parallel to the changes in bladder volume. The reality of the simulation was inspected. Three-millimeter-slice-increment computed tomography (CT) scans were taken for irradiation planning. The structure set was adapted to the phantom from a treated patient. Planning target volume was delineated according to the RTOG 0126 study. IMRT and 3D conformal radiation therapy (3D-CRT) plans were made. Prostate motion and rectum volume changes were simulated in the phantom. IC displacement was corrected by phantom shifting. The delivered dose was measured with IC in 7 cases using intensity-modulated radiation therapy (IMRT) and 3D-CRT fractions, and single square-shaped beams: anteroposterior (AP), posteroanterior (PA), and lateral (LAT). Variations from the calculated doses were slightly below 1% at IMRT and around 1% at 3D-CRT; below 4.5% at square AP beam; up to 9% at square PA beam; and around 0.5% at square LAT beam. Other authors have already shown that by using planning systems and ultrasonic and cone beam CT guidance, correction of organ motions in a real patient during prostate cancer IGRT does not have a significant dosimetric effect. The inspection of our phantom-as described here-ended with similar results. Our team suggested that our model is sufficiently realistic and can be used for IGRT and ART testing.

61 RADIATION PROTECTION AND DOSIMETRY↗

Measurement of transformer ratio from ramped beams in the blowout regime

We present the plans for a UCLA-Argonne collaborative plasma wakefield acceleration (PWFA) experiment aimed at demonstrating the dependence of transformer ratio - the relation between maximum acceleration observed in a plasma wake to the maximum deceleration of the driving beam - on beam shape. Utilizing the unique capabilities of the emittance exchange (EEX) beamline, we may obtain transformer ratios in excess of six in a 120 MeV/m PWFA. These experiments are a crucial step in enabling applications ranging from compact X-ray free electron laser (FEL) light sources to TeV-class linear colliders for high energy physics.

Linear↗

Planck 2015 results: VI. LFI mapmaking

This article describes the mapmaking procedure applied to Planck Low Frequency Instrument (LFI) data. The mapmaking step takes as input the calibrated timelines and pointing information. The main products are sky maps of I, Q, and U Stokes components. For the first time, we present polarization maps at LFI frequencies. The mapmaking algorithm is based on a destriping technique, which is enhanced with a noise prior. The Galactic region is masked to reduce errors arising from bandpass mismatch and high signal gradients. We apply horn-uniform radiometer weights to reduce the effects of beam-shape mismatch. The algorithm is the same as used for the 2013 release, apart from small changes in parameter settings. We validate the procedure through simulations. Special emphasis is put on the control of systematics, which is particularly important for accurate polarization analysis. We also produce low-resolution versions of the maps and corresponding noise covariance matrices. These serve as input in later analysis steps and parameter estimation. The noise covariance matrices are validated through noise Monte Carlo simulations. The residual noise in the map products is characterized through analysis of half-ring maps, noise covariance matrices, and simulations.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of Hard X-ray Imaging Optics with Two Pairs of Elliptical and Hyperbolic Mirrors

To form a magnified hard X-ray image with a 50 nm resolution, we have studied total reflection mirror optics with two pairs of elliptical and hyperbolic mirrors, which is called 'Advanced Kirkpatrick-Baez system'. A designed optical system has 200x and 300x magnifications in vertical and horizontal directions. Also diffraction limit size in the optical system is 40 nmx45 nm. We fabricated a pair of elliptical and hyperbolic mirrors for horizontal imaging with a figure accuracy of 2 nm using elastic emission machining (EEM), microstitching interferometry (MSI) and relative-angle-determinable stitching interferometry (RADSI). One-dimensional tests for forming a demagnified image of a slit were carried out at an X-ray energy of 11.5 keV at BL29XUL (EH2) of SPring-8. As a result, a shape beam with a FWHM of 78 nm was observed. This demonstrates that we realized one-dimensional Wolter optics that has a spatial resolution of 78 nm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Treatment Planning for Accelerator-Based Boron Neutron Capture Therapy

Glioblastoma multiforme and metastatic melanoma are frequent brain tumors in adults and presently still incurable diseases. Boron Neutron Capture Therapy (BNCT) is a promising alternative for this kind of pathologies. Accelerators have been proposed for BNCT as a way to circumvent the problem of siting reactors in hospitals and for their relative simplicity and lower cost among other advantages. Considerable effort is going into the development of accelerator-based BNCT neutron sources in Argentina. Epithermal neutron beams will be produced through appropriate proton-induced nuclear reactions and optimized beam shaping assemblies. Using these sources, computational dose distributions were evaluated in a real patient with diagnosed glioblastoma treated with BNCT. The simulated irradiation was delivered in order to optimize dose to the tumors within the normal tissue constraints. Using Monte Carlo radiation transport calculations, dose distributions were generated for brain, skin and tumor. Also, the dosimetry was studied by computing cumulative dose-volume histograms for volumes of interest. The results suggest acceptable skin average dose and a significant dose delivered to tumor with low average whole brain dose for irradiation times less than 60 minutes, indicating a good performance of an accelerator-based BNCT treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multi-resonant wideband energy harvester based on a folded asymmetric M-shaped cantilever

This article reports a compact wideband piezoelectric vibration energy harvester consisting of three proof masses and an asymmetric M-shaped cantilever. The M-shaped beam comprises a main beam and two folded and dimension varied auxiliary beams interconnected through the proof mass at the end of the main cantilever. Such an arrangement constitutes a three degree-of-freedom vibrating body, which can tune the resonant frequencies of its first three orders close enough to obtain a utility wide bandwidth. The finite element simulation results and the experimental results are well matched. The operation bandwidth comprises three adjacent voltage peaks on account of the frequency interval shortening mechanism. The result shows that the proposed piezoelectric energy harvester could be efficient and adaptive in practical vibration circumstance based on multiple resonant modes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Environmental influences on autocollimator-based angle and form metrology

Deflectometric profilometers are indispensable tools for the precision form measurement of beam-shaping optics of synchrotrons and x-ray free electron lasers. They are used in metrology labs for x-ray optics worldwide and are crucial for providing measurement accuracy dictated by the form tolerances for modern state-of-the-art x-ray optics. Deflectometric profilometers use surface slope (angle) to assess form, and they utilize commercial autocollimators for the contactless slope measurement. In this contribution, we discuss the influences of environmental parameters, such as temperature and air pressure, including their gradients, on high-accuracy metrology with autocollimators in profilometers. They can cause substantial systematic errors in form measurement, especially in the case of large and strongly curved optical surfaces of high dynamic range. Relative angle and form measuring errors of the order of 10 -4 are to be expected. We characterize environmental influences by extended theoretical and experimental investigations and derive strategies for correcting them. Additionally, we report on the possibility to minimize the contributions of some errors by the application of sophisticated experimental arrangements and methods. We aim at approaching fundamental limits in autocollimator-based slope and form metrology.

47 OTHER INSTRUMENTATION↗

Magnetized liner inertial fusion platform development to assess performance scaling with drive parameters

Magnetized liner inertial fusion (MagLIF) experiments have demonstrated fusion-relevant ion temperatures up to 3.1 keV and thermonuclear production of up to 1.1 × 1013 deuterium–deuterium neutrons. This performance was enabled through platform development that provided increases in applied magnetic field, coupled preheat energy, and drive current. Advanced coil designs with internal reinforcement enabled an increase from 10 to 20 T. An improved laser pulse shape, beam smoothing, and thinner laser entrance foils increased preheat energy coupling from less than 1 to 2.3 kJ. A redesign of the final transmission line and load region increased peak load current from 16 to 20 MA. The wider range of input parameters was leveraged to study target performance trends with preheat energy, applied magnetic field, and peak load current. Ion temperature and neutron yield generally followed trends in two-dimensional clean Lasnex calculations. Stagnation performance improved with peak load current when other input parameters were also increased such that convergence was maintained. This dataset suggests that reducing convergence to less than 30 would improve predictability of target performance. Lasnex was used to identify a simulation-optimized scaling path, which suggests 10+ kJ of fusion yield is possible on the Z facility with achievable input parameters. This path also indicates >10 MJ could be generated through volume burn on a future facility with a path to high yield (>200 MJ) using cryogenic dense fuel layers. The newly developed MagLIF platform enables exploration of both this simulation optimized scaling path and a recently developed similarity-scaling path.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

THE GALFA-HI SURVEY: DATA RELEASE 1

We present the Galactic Arecibo L-Band Feed Array H I (GALFA-H I) survey and its first full data release (DR1). GALFA-H I is a high-resolution ({approx}4'), large-area (13,000 deg{sup 2}), high spectral resolution (0.18 km s{sup -1}), and wide band (-700 km s {sup -1} < v{sub LSR} < +700 km s{sup -1}) survey of the Galactic interstellar medium in the 21 cm line hyperfine transition of neutral hydrogen conducted at Arecibo Observatory. Typical noise levels are 80 mK rms in an integrated 1 km s{sup -1} channel. GALFA-H I is a dramatic step forward in high-resolution, large-area Galactic H I surveys, and we compare GALFA-H I to past, present, and future Galactic H I surveys. We describe in detail new techniques we have developed to reduce these data in the presence of fixed pattern noise, gain variation, and inconsistent beam shapes, and we show how we have largely mitigated these effects. We present our first full data release, covering 7520 deg{sup 2} of sky and representing 3046 hr of integration time, and discuss the details of these data.

79 ASTRONOMY AND ASTROPHYSICS↗

Chiral Topological Surface States on a Finite Square Photonic Crystal Bounded by Air

Chiral, topologically protected, photonic surface states can be found at the boundary between gyrotropic photonic crystals where a changing magnetic field induces different topology across the interface. Typically, photonic crystals with either a suitable band structure on both sides of the interface to provide a band gap and evanescent decay of the surface states away from the interface, or an outer layer with engineered material properties is required. In this paper, we show the emergence of topological, unidirectional surface states at the termination of finite gyrotropic photonic crystals with a simple square lattice and C 4 rotational symmetry bounded by a vacuum, eliminating the need for an outside layer to enable chiral surface modes. Here, we start from an infinite, time-reversal-symmetry-breaking photonic crystal with a band gap associated with bands with nonzero Chern numbers, different from all-zero Chern numbers in air. We then modify the photonic crystal to move this band gap below the light line, while maintaining the Chern-number discontinuities. Band-structure calculations for a supercell approximating a photonic crystal finite in the direction normal to the surface demonstrate the existence, dispersion, and chirality of the surface mode. Extensive direct scattering calculations for a point source and spatial Fourier analysis further reveal a unidirectional free-space topological surface state, which propagates counterclockwise around the surface of a finite photonic crystal, providing a nearly foolproof way to cross-check the surface-mode band structure unaffected by backscattering from local defects. Additionally, scattering simulations allow an independent characterization of the state dispersion and unveil the robustness of the topological plasmonic mode propagation around the 90° bends of the structure, being due to only radiation leakage. In contrast to buried topological surface states, the observed surface modes at the photonic crystal–air interface have the advantage of being accessible to the outside world, allowing one to take advantage of the defect-tolerant backscattering-free surface modes to engineer emission from photonic crystal surfaces into arbitrary free-space beam shapes and directions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fresnel diffraction of spin waves

Here, the propagation of magnetostatic forward volume waves excited by a constricted coplanar waveguide is studied via inductive spectroscopy techniques. A series of devices consisting of pairs of submicrometer size antennae is used to perform a discrete mapping of the spin wave amplitude in the plane of a 30-nm thin YIG film. We found that the spin wave propagation remains well focused in a beam shape of width comparable to the constriction length and that the amplitude within the constriction displays oscillations, two features which are explained in terms of near-field Fresnel diffraction theory.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Exotic Non-Abelian Topological Defects in Lattice Fractional Quantum Hall States

We investigate extrinsic wormholelike twist defects that effectively increase the genus of space in lattice versions of multicomponent fractional quantum Hall systems. Although the original band structure is distorted by these defects, leading to localized midgap states, we find that a new lowest flat band representing a higher genus system can be engineered by tuning local single-particle potentials. Remarkably, once local many-body interactions in this new band are switched on, we identify various Abelian and non-Abelian fractional quantum Hall states, whose ground-state degeneracy increases with the number of defects, i.e, with the genus of space. This sensitivity of topological degeneracy to defects provides a “proof of concept” demonstration that genons, predicted by topological field theory as exotic non-Abelian defects tied to a varying topology of space, do exist in realistic microscopic models. Specifically, our results indicate that genons could be created in the laboratory by combining the physics of artificial gauge fields in cold atom systems with already existing holographic beam shaping methods for creating twist defects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

To scavenge or not to scavenge, that is STILL the question

An extensive radiation chemistry literature would suggest that the addition of certain radical scavengers might mitigate the effects of radiation damage during protein crystallography diffraction data collection. However, attempts to demonstrate and quantify such an amelioration and its dose dependence have not yielded consistent results, either at room temperature (RT) or 100K. Here the information thus far available is summarized and reasons for this lack of quantitative success are identified. Firstly, several different metrics have been used to monitor and quantify the rate of damage, and, as shown here, these can give results which are in conflict regarding scavenger efficacy. In addition, significant variation in results from data collected from crystals treated in nominally the same way has been observed. Secondly, typical crystallization conditions contain substantial concentrations of chemical species which already interact strongly with some of the X-ray-induced radicals that the added scavengers are intended to intercept. These interactions are probed here by the complementary technique of on-line microspectrophotometry carried out on solutions and crystals held both at 100K and RT, the latter enabled by the use of a beamline-mounted humidifying device. With the help of computational chemistry, attempts are made to assign some of the characteristic spectral features observed experimentally. A further source of uncertainty undoubtedly lies in the challenge of reliably measuring the parameters necessary for the accurate calculation of the absorbed dose (e.g. crystal size and shape, beam profile) and its distribution within the volume of the crystal (an issue addressed in detail in another article in this issue). While microspectrophotometry reveals that the production of various species can be quenched by the addition of scavengers, it is less clear that this observation can be translated into a significant gain in crystal dose tolerance for macromolecular crystallographers.

47 OTHER INSTRUMENTATION↗

Self-calibration strategies for reducing systematic slope measurement errors of autocollimators in deflectometric profilometry

Deflectometric profilometers are used to precisely measure the form of beam shaping optics of synchrotrons and X-ray free-electron lasers. They often utilize autocollimators which measure slope by evaluating the displacement of a reticle image on a detector. Based on our privileged access to the raw image data of an autocollimator, novel strategies to reduce the systematic measurement errors by using a set of overlapping images of the reticle obtained at different positions on the detector are discussed. It is demonstrated that imaging properties such as, for example, geometrical distortions and vignetting, can be extracted from this redundant set of images without recourse to external calibration facilities. This approach is based on the fact that the properties of the reticle itself do not change – all changes in the reticle image are due to the imaging process. Firstly, by combining interpolation and correlation, it is possible to determine the shift of a reticle image relative to a reference image with minimal error propagation. Secondly, the intensity of the reticle image is analysed as a function of its position on the CCD and a vignetting correction is calculated. Thirdly, the size of the reticle image is analysed as a function of its position and an imaging distortion correction is derived. It is demonstrated that, for different measurement ranges and aperture diameters of the autocollimator, reductions in the systematic errors of up to a factor of four to five can be achieved without recourse to external measurements.

47 OTHER INSTRUMENTATION↗

Photonic Crystal Surface Emitting GaSb-Based Type-I Quantum Well Diode Lasers

The GaSb-based epitaxially regrown monolithic diode PCSELs operating near 2 μm at room temperature in continuous wave regime and generating 30 mW of output power from 200 μm diameter aperture have been designed and fabricated. Here, the devices demonstrated CW threshold current density of about 500 A/cm 2 . The laser output power was enhanced thanks to increased buried void area fill-factor in the photonic crystal layer with multiple voids per unit cell. The PCSEL generated ultra-low divergence donut shape beams at the currents near threshold. At higher injection currents, the device brightness was limited by excitation of the higher order lateral modes. Generation of the vector-vortex beams of different types by different band edge states of the buried photonic crystal was observed.

77 NANOSCIENCE AND NANOTECHNOLOGY↗